1
|
Safety and Efficacy of the Erbium Laser in Debonding Dental Accessories: A Narrative Review. Photobiomodul Photomed Laser Surg 2024; 42:327-338. [PMID: 38598279 DOI: 10.1089/photob.2023.0139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024] Open
Abstract
Objective: This article aims to review the safety and efficacy of the Er:YAG laser in debonding dental accessories. Methods: This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Articles published between 2010 and 2022 on the removal of dental accessories using erbium laser were searched. The selected articles were then classified according to the accessories used: adhesives, brackets, restorations, or implant crowns. Enamel surface roughness, shear bond strength, adhesive remnant index, duration time (t), pulp chamber temperature (T), morphology (M), and other variables were then noted. Results: The dental accessories and adhesives used were described along with the laser parameters used, such as frequency, pulse width, irradiation time, scanning mode, water-air cooling, and other variables. Conclusions: Laser removal using Er:YAG laser of dental accessories such as brackets, crowns, and veneers is fundamentally safe, time-saving, and does not cause damage to the enamel nor the underlying dentin. However, there was no distinct advantage with laser removal seen, such as those residual adhesives of brackets on the tooth surface and temporary adhesives of restorations.
Collapse
|
2
|
Er:YAG laser settings for debonding zirconia restorations: An in vitro study. J Mech Behav Biomed Mater 2024; 151:106331. [PMID: 38176195 DOI: 10.1016/j.jmbbm.2023.106331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 01/06/2024]
Abstract
This in vitro study aimed to determine the optimal frequency and energy settings for debonding zirconia restorations using an erbium-doped yttrium aluminum garnet (Er:YAG) laser. A total of 200 zirconia specimens (5 mm × 5 mm × 1.5 mm) were fabricated from two types of materials: (1) 3 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (3Y-TZP) and (2) 5 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (5Y-TZP). The zirconia specimens were bonded to dentin using resin cement (RelyX Ultimate, 3 M) and divided into 20 groups based on their laser treatments (n = 5). Er:YAG laser treatment was applied at various frequencies (10 Hz and 20 Hz) and energies (80 mJ, 100 mJ, 120 mJ, 140 mJ, 160 mJ, 180 mJ, 200 mJ, 220 mJ, 240 mJ, and 260 mJ). The time required to debond the specimens and the temperature changes that dentin underwent during the laser treatment were recorded. The surface morphologies of the debonded dentin and zirconia specimens were observed using scanning electron microscopy (SEM). Additional zirconia specimens were fabricated for 4-point flexural strength testing and surface roughness measurements. Statistical analyses were conducted using three-way analysis of variance (ANOVA) and Student-Newman-Keuls (SNK)-q tests (α = 0.05). The debonding time of each specimen varied between 4.8 and 160.4 s, with an average value of 59.2 s. The dentin temperature change for each specimen ranged from 2.3 to 3.6 °C, with an average value of 2.7 °C. The debonding time was significantly influenced by the zirconia material type and laser energy, but it was not affected by the laser frequency. Among the specimens, those made of 3Y-TZP needed significantly more time for debonding than 5Y-TZP. The optimal energies were 220 mJ for 3Y-TZP and 200 mJ for 5Y-TZP. The laser frequency, laser energy, and type of zirconia material had no effect on the dentin temperature change. Additionally, no surface alternations were observed on the dentin or zirconia materials after laser treatment. The surface roughness and flexural strength of the zirconia materials remained unchanged after laser treatment. In summary, Er:YAG laser treatment effectively and safely removes zirconia restorations without impacting their mechanical properties, with a safe temperature change of less than 5.6 °C. The optimum frequency and energy settings for debonding 3Y-TZP and 5Y-TZP restorations were found to be 10/20 Hz and 220 mJ and 10/20 Hz and 200 mJ, respectively.
Collapse
|
3
|
Evaluation of the effectiveness and practicality of erbium lasers for ceramic restoration removal: A retrospective clinical analysis. PLoS One 2023; 18:e0295957. [PMID: 38096248 PMCID: PMC10721072 DOI: 10.1371/journal.pone.0295957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 12/03/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND The purpose of this study was to assess the effectiveness and practicality of erbium lasers in the removal of ceramic restorations and appliances from natural teeth and dental implant abutments in clinical practice. METHODS A retrospective analysis was conducted, involving 29 clinical cases with a total of 52 abutments requiring the removal of various ceramic restorations. The analysis evaluated the clinical procedures performed, including the type and material of the prosthetic, the type of cement used, laser setting parameters, retrieval time, and retrieval success. RESULTS Out of the 52 abutments, 50 were successfully retrieved without causing any damage (>95%) using either an Er,Cr:YSGG laser (N = 6) or an Er:YAG laser (N = 46). In one case, a crown was partially sectioned to prevent any negative impact of laser irradiation on the adhesive strength between the post and tooth, and in another case, a fracture occurred during debonding. The restorations consisted of 13 lithium disilicate and 39 zirconia units, including six veneers, 38 single crowns, and three fixed partial dentures (FPDs). The retrieval time varied depending on the restoration type, material thickness, cement type, retention form/fitting of the abutment and restoration, ranging from 2.25 ±0.61 minutes for veneers, 6.89 ±8.07 minutes for crowns, to 25 ±10 minutes per abutment for FPDs. Removal of a zirconia crown required more time, 7.12±8.91 minutes, compared to a lithium disilicate crown, 5.86 ±2.41 minutes. The debonding time was influenced by the laser settings as well as materials and types of prosthesis. CONCLUSIONS Erbium lasers present a safe and effective alternative to invasive methods for removing ceramic restorations, without causing harm to the abutment or prosthesis. Laser-assisted debonding allows for recementation of the restorations during the same appointment, making it a conservative and viable option for ceramic crown retrieval in clinical settings.
Collapse
|
4
|
Chemical and morphological analysis of dentin irradiated by different high-power lasers: a systematic review. Lasers Med Sci 2023; 38:255. [PMID: 37932490 DOI: 10.1007/s10103-023-03912-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 10/12/2023] [Indexed: 11/08/2023]
Abstract
PURPOSE This systematic review provides an overview of the main chemical and morphological alterations generated on dentin by different high-power lasers' irradiation. METHODS The review was registered in PROSPERO (CRD42023394164) and PRISMA guidelines were followed. The search strategy was conducted on MEDLINE (PubMed), Embase (Elsevier), and Web of Science (Clarivate) databases. The eligibility criteria were established according to the PICOS strategy, focusing on in vitro and ex vivo studies that assessed the chemical and morphological changes in dentin using five high-power lasers: Nd:YAG (1064 nm), Er:YAG (2940 nm), Er, Cr:YSGG (2780 nm), diode (980 nm), and CO2 (10,600 nm). Publication range was from 2010 to 2022. Data was summarized in tables and risk of bias was assessed by QUIN tool. RESULTS The search resulted in 2255 matches and 57 studies composed the sample. The methods most used to assess the outcomes were scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and Raman. The studies presented "medium" and "low" risk of bias. The laser prevalently identified was the Er:YAG laser, associated with dentin ablation, absence of smear layer, and exposed tubules. The Nd:YAG laser generated vitreous surface and thermal damage, such as carbonization and cracks. The other lasers caused an irregular surface and no adverse thermal effects. Regarding the chemical structure, only the Er,Cr:YSGG laser caused collagen matrix reduction. The effects found were more intense with higher dosimetry. CONCLUSION Evidence available indicates that the irradiation of dentin with high-power lasers are related to morphological outcomes favorable to adhesive restorative procedures, with minimal changes in collagen matrix and mineral content. However, those observations should be carried carefully by clinicians and more clinical trials regarding the association of high-power laser irradiation and restorative procedure longevity are needed.
Collapse
|
5
|
Do erbium lasers promote changes in the tooth enamel during debonding of ceramic laminate veneers? A systematic review. Lasers Med Sci 2023; 38:217. [PMID: 37735282 DOI: 10.1007/s10103-023-03882-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 09/13/2023] [Indexed: 09/23/2023]
Abstract
The longevity of ceramic laminate veneers can be influenced by several factors, which can result in the need for a removal process. Laser removal has emerged as a good alternative to facilitate the procedure, and its repercussions on tooth enamel have been investigated. We aimed to evaluate the efficacy of erbium lasers for debonding ceramic laminate veneers without damaging the tooth enamel. This systematic review based on the PICOS model adhered to the PRISMA statement. The PubMed/MEDLINE, Web of Science, Embase, and Scopus databases were systematically searched until December 1, 2022, and 2902 studies were retrieved. After screening, four in vitro studies that analyzed the dental morphology using scanning electron microscopy, optical analysis, stereomicroscopy, or x-ray dispersion spectroscopy were included. The risk of bias was assessed using the Cochrane Collaboration tool. Our findings suggest that erbium lasers are useful for ceramic laminate veneer removal without damaging the tooth enamel. However, the removal is influenced by the type and thickness of ceramic and type of cement used. It could be concluded that the application of Erbium laser did not promote superficial changes in the dental enamel. This effect was observed in all analysis performed.
Collapse
|
6
|
Effect of Dentin and Zirconia Surface Treatments with Laser Irradiation Versus Sandblasting on the Bonding Ability of Zirconia. Photobiomodul Photomed Laser Surg 2023; 41:501-508. [PMID: 37651219 DOI: 10.1089/photob.2022.0154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/02/2023] Open
Abstract
Objective: This study aimed to investigate the effects of laser irradiation applied to zirconia and tooth surfaces on shear bond strength (SBS) compared with acid etching and sandblasting. Background: The effect of laser irradiation on the bond strength between zirconia and adhesives is a controversial issue for dentin surface treatments. In addition, the effects of different combinations of surface treatments to increase adhesion on both the zirconia and dentin surfaces remain unclear. Materials and methods: A total of 90 tooth samples were assigned into groups according to various pretreatments: control group was left untreated, acid etching, and Erbium, Chromium:Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser irradiation group (15 Hz, 2 W). In addition, the zirconia specimens were separated into three groups (n = 10) according to the different surface treatments performed: sandblasting (120 μm Al2O3), Er,Cr:YSGG laser (15 Hz, 2 W), and as untreated surface. The zirconia samples were cemented to the dentin surface using dual-cure resin cement and subjected to an SBS test at a speed of 0.5 mm/min under a universal testing machine until fractures occurred in the bonding surface. Results: The highest SBS values were observed in Group tooth acid (TA)-zirconia Er,Cr:YSGG laser (ZL), followed by Group tooth Er,Cr:YSGG laser (TL)-zirconia sandblasting (ZS) and Group TA-zirconia control (ZC). The lowest SBS values were found in Group TA-ZS. Significant intergroup difference was noted between Group TA-ZL, Group tooth control (TC)-ZC, Group TL-ZS, and Group TC-ZC. However, no significant difference was noted between Group TA-ZL, Group TL-ZS, and Group TA-ZC. Conclusions: Acid etching and laser treatments applied to the dentin and zirconia surfaces were found to be effective techniques for improving the zirconia-dentin bond, respectively. Clinical Trial Registration number: 33216249-604.01.02-E.24308.
Collapse
|
7
|
Optimized Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) Laser Parameters for the Removal of Dental Ceramic Restorations. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5835. [PMID: 37687528 PMCID: PMC10488396 DOI: 10.3390/ma16175835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/10/2023]
Abstract
OBJECTIVES The use of lasers for debonding adhesively luted ceramic restorations is a rather recent oral laser application in dentistry. The removal of all-ceramic restorations in the mouth can often be a troublesome task. A novel method for the debonding of ceramic restorations without damaging the restorations is Er:YAG laser irradiation. The aim of this study was to evaluate the Er:YAG laser for debonding procedures of different dental ceramics and to identify appropriate laser settings. MATERIAL AND METHODS Lithium disilicate, zirconium-reinforced lithium silicate, feldspatic ceramic, and zirconium dioxide were investigated. Ten ceramic rectangular-shaped specimens with 1 and 2 mm thickness were produced from each material. All specimens were irradiated with four different power settings 1.5; 2.5; 3.5; 4.5 W, pulse duration 50 μs, laser repetition rate 10 Hz, time of irradiation 10 s. The transmitted energy was measured with a powermeter. Additionally the suitability of the Er:YAG laser to remove the adhesively bonded ceramic and the time until loss of retention was evaluated. RESULTS The transmission rate for 1 and 2 mm platelets was determined for zirconium-reinforced lithium silicate at 54.6%/35.6%, lithium disilicate at 53.2%/35.7%, zirconium dioxide at 40.6%/32.4%, and for the feldspathic ceramic at 19.4%/10.1%. For zirconium-reinforced lithium silicate and zirconium dioxide 2.5 W (250 mJ/10 Hz) was an appropriate energy level for effective debonding. Whereas for lithium disilicate and for feldspathic ceramic, 4.5 W (450 mJ/10 Hz) is required for efficient debonding. CONCLUSIONS There are differences regarding transmission rates between ceramic types for the Er:YAG laser light and additionally depending on the type of ceramic different energy settings should be used for adequate debonding. Based on our in-vitro experiments we recommend 2.5 W for zirconium-reinforced lithium silicate and zirconium dioxide and 4.5 W for lithium disilicate and feldspatic ceramic. Transmission rates of different ceramic types and varying influences of thicknesses and bonding materials should be considered to adjust the laser parameters during laser debonding of adhesively luted all-ceramic restorations.
Collapse
|
8
|
Erbium laser-assisted ceramic debonding: a scoping review. J Prosthodont 2022; 31:e100-e124. [PMID: 36269672 PMCID: PMC10099628 DOI: 10.1111/jopr.13613] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 10/13/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE Removal of ceramic restorations and appliances can be time consuming, invasive, and inconvenient. Erbium lasers offer an alternative noninvasive method for debonding of ceramic appliances. This paper aims to provide a comprehensive review of current literature on the effectiveness of erbium lasers for removal of ceramic restorations and appliances from natural teeth and dental implants. METHODS A comprehensive search of 7 databases, including Medline (Ovid), Embase, Dentistry and Oral Sciences Source (DOSS), Web of Science, Cochrane Library, and ProQuest Dissertations and Theses was performed. The inclusion and exclusion criteria were agreed prior to the literature search. Two reviewers independently screened the title and abstract. A third reviewer then broke the tie, if any. The selected articles then underwent full text review and the data was extracted. RESULTS The search identified 4117 unique articles published through June 10, 2021. Studies were assessed and categorized based on the type of restoration/appliance, type of abutment, type of laser, laser settings, efficacy of debonding, and pulpal temperature rise. Thirty-eight full-text articles were reviewed for inclusion. Time for ceramic debonding varies depending on the type of restorations and materials. Removal of zirconia crowns from teeth and implant abutments requires a longer period of time compared to lithium disilicate crowns. Temperature increases were reported as 5.5 degrees or less. Laser setting and laser type affect the debonding time and the increase in temperature. Examinations of debonded ceramics demonstrated no known structural damages resulting from laser applications. CONCLUSIONS Erbium lasers are effective noninvasive tools to remove all ceramic restorations/appliances from natural teeth and implant abutments without causing harm to abutments. Laser-assisted debonding should be considered as a viable alternative to rotary instrumentation for ceramic crowns; however, clinical studies of erbium-assisted ceramic retrieval are needed.
Collapse
|
9
|
Er:YAG laser removal of zirconia crowns on titanium abutment of dental implants: an in vitro study. BMC Oral Health 2022; 22:396. [PMID: 36096836 PMCID: PMC9469558 DOI: 10.1186/s12903-022-02427-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 09/01/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND This research aimed to explore feasibility and the time required when erbium-doped yttrium aluminum garnet (Er:YAG) laser as a non-invasive treatment modality to retrieve different thicknesses of zirconia material bonded by two dental cements from titanium implant abutments. METHODS Prepared 80 titanium blocks (length: 20 mm, width: 10 mm, height: 10 mm) and square zirconia sheets (length: 10 mm) with different thicknesses (1 mm, 2 mm, 3 mm, and 4 mm) were 20 pieces each. Resin modified glass ionomer cement (RelyX Luting 2; RXL) and resin cement (Clearfil SA luting; CSL) were used to bond zirconia sheet and titanium block. Specimens were kept in 100% humidity for 48 h. Er:YAG laser was used to retrieve the zirconia sheet and recorded the time. Universal testing machine was used to measure the residual adhesion of the samples that did not retrieve after 5 min of laser irradiation. Shear bond strength (MPa) and the time data (s) were analyzed using Kruskal-Wallis Test. The bonding surface and the irradiation surface of the zirconia sheet was examined with the scanning electron microscopy (SEM). RESULTS Within 5 min of laser irradiation, RXL group: 1 mm group all fell off, 2 mm group had 3 specimens did not fall off, there was no statistical difference in the average time between the two groups; CSL group: half of the 1 mm group fell off. Shear bond strength test results: there was no statistical difference between 1 and 2 mm in RXL group and 1 mm in CSL group, there was no statistical difference between 3 mm in RXL group and 2 mm in CSL group, and there were significant differences statistically in comparison between any two groups in the rest. SEM inspection showed that the bonding surface and the irradiation surface of the zirconia sheet had changes. CONCLUSION In this vitro study, the following could be concluded: it is faster to remove zirconia crowns with thickness less than 2 mm from titanium abutment when luted with RelyX Luting 2 compared to Clearfil SA luting.
Collapse
|
10
|
In Vitro Study of Laser-Assisted Prefabricated Ceramic Crown Debonding as Compared to Traditional Rotary Instrument Removal. MATERIALS 2022; 15:ma15103617. [PMID: 35629643 PMCID: PMC9143968 DOI: 10.3390/ma15103617] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/14/2022] [Accepted: 05/17/2022] [Indexed: 11/16/2022]
Abstract
This study compared the laser and rotary removals of prefabricated zirconia crowns in primary anterior and permanent posterior teeth. Sixty-two extracted teeth were prepared for prefabricated zirconia crowns cemented with resin-modified glass-ionomer cement. Specimens underwent crown removals by a rotary handpiece, or erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser. Pulpal temperatures, removal times, and scanning electron microscopy (SEM) examinations were compared. The average crown removal time for rotary and laser methods was 80.9 ± 19.36 s and 353.3 ± 110.6 s, respectively, for anterior primary teeth; and 114.2 ± 32.1 s and 288.5 ± 76.1 s, respectively, for posterior teeth (p < 0.001). The maximum temperature for the rotary and laser groups was 22.2 ± 8.5 °C and 27.7 ± 1.6 °C for anterior teeth, respectively (p < 0.001); and 21.8 ± 0.77 °C and 25.8 ± 0.85 °C for the posterior teeth, respectively (p < 0.001). More open dentinal tubules appeared in the rotary than the laser group. The rotary handpiece removal method may be more efficient than the laser with lower pulpal temperature changes. However, the laser method does not create noticeable tooth or crown structural damage compared to the rotary method.
Collapse
|
11
|
Evaluation of Er,Cr:YSGG laser irradiation for debonding of zirconia hybrid abutment crowns from titanium bases. Lasers Med Sci 2022; 37:2675-2685. [DOI: 10.1007/s10103-022-03539-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 02/28/2022] [Indexed: 10/18/2022]
|