1
|
Nimmal Haribabu G, Basu B. Implementing Machine Learning approaches for accelerated prediction of bone strain in acetabulum of a hip joint. J Mech Behav Biomed Mater 2024; 153:106495. [PMID: 38460455 DOI: 10.1016/j.jmbbm.2024.106495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/10/2024] [Accepted: 03/01/2024] [Indexed: 03/11/2024]
Abstract
The Finite Element (FE) methods for biomechanical analysis involving implant design and subject parameters for musculoskeletal applications are extensively reported in literature. Such an approach is manually intensive and computationally expensive with longer simulations times. Although Artificial Intelligence (AI) based approaches are implemented to a limited extent in biomechanics, such approaches to predict bone strain in acetabulum of a hip joint, are hardly explored. In this context, the primary objective of this paper is to evaluate machine learning (ML) models in tandem with high-fidelity FEA data for the accelerated prediction of the biomechanical response in the acetabulum of the human hip joint, during the walking gait. The parameters used in the FEA study included the subject weight, number and distribution of fins on the periphery of the acetabular shell, bone condition and phases of the gait cycle. The biomechanical response has also been evaluated using three different acetabular liners, including pre-clinically validated HDPE-20% HA-20% Al2O3, highly-crosslinked ultrahigh molecular weight polyethylene (HC-UHMWPE) and ZrO2-toughened Al2O3 (ZTA). Such parametric variation in FEA analysis, involving 26 variables and a full factorial design resulted in 10,752 datasets for spatially varying bone strains. The bone condition, as opposed to subject weight, was found to play a statistically significant role in determining the strain response in the periprosthetic bone of the acetabulum. While utilising hyperparameter tuning, K-fold cross validation and statistical learning approaches, a number of ML models were trained on the FEA dataset, and the Random Forest model performed the best with a coefficient of determination (R2) value of 0.99/0.97 and Root Mean Square Error (RMSE) of 0.02/0.01 on the training/test dataset. Taken together, this study establishes the potential of ML approach as a fast surrogate of FEA for implant biomechanics analysis, in less than a minute.
Collapse
Affiliation(s)
- Gowtham Nimmal Haribabu
- Laboratory for Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
2
|
Zitsch BP, Cahoy KM, Urban ND, Buckner BC, Garvin KL. Highly Cross-Linked Polyethylene in Patients 50 Years of Age and Younger: A 20-year Follow-Up Analysis. J Arthroplasty 2024:S0883-5403(24)00267-5. [PMID: 38548239 DOI: 10.1016/j.arth.2024.03.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/15/2024] [Accepted: 03/18/2024] [Indexed: 04/21/2024] Open
Abstract
BACKGROUND Highly cross-linked polyethylene (HXLPE) has been an excellent bearing for total hip arthroplasty (THA) due to improved wear characteristics compared to conventional materials. Patients 50 years of age or younger are at high risk for wear-related complications of their THA, and few studies have followed these patients who have HXPLE into the third decade. METHODS In a retrospective review of 88 consecutive THAs performed in 77 patients aged 50 years and younger (mean 41; range, 20 to 50), in which HXLPE was utilized, they were evaluated for their clinical and radiographic results at an average of 20-year follow-up (range, 18 to 24). The current study reports on longer-term follow-up from our previously published series at shorter follow-up times. Patients were categorized by femoral head material: cobalt chrome (n = 14), ceramic (n = 30), and oxidized zirconium (n = 22) and by femoral head size: 26 mm (n = 12), 28 mm (n = 46), and 32 mm (n = 8). Harris Hip Scores were collected preoperatively and at the most recent follow-up. Radiographs were evaluated for linear and volumetric wear, radiolucent lines, and osteolysis. RESULTS Mean Harris Hip Scores improved from 47.1 (standard deviation [SD] 8.8) preoperatively to 92.0 (SD 7.7) (P < .0001) at 20-year follow-up. There was one hip that was revised for recurrent instability, and no hip demonstrated radiographic evidence of loosening or osteolysis. The mean polyethylene linear wear rate was 0.017 (SD 0.012) mm/y, and the mean polyethylene volumetric wear rate was 3.15 (SD 2.8) mm3/year, with no significant differences based on articulation type or head size. CONCLUSIONS Total hip arthroplasty with HXLPE in patients ≤ 50 years of age continues to demonstrate excellent long-term clinical and radiographic outcomes with low wear characteristics at 20-year follow-up, regardless of femoral head material or size.
Collapse
Affiliation(s)
- Bradford P Zitsch
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| | - Kevin M Cahoy
- College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Nathanael D Urban
- College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Brandt C Buckner
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| | - Kevin L Garvin
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| |
Collapse
|
3
|
English RT, Munro JT, Monk AP. Increasing femoral head size from 32 mm to 36 mm does not increase the revision risk for total hip replacement: a New Zealand joint registry study. Hip Int 2024; 34:66-73. [PMID: 37932243 DOI: 10.1177/11207000231210487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2023]
Abstract
BACKGROUND The use of larger femoral heads in total hip replacement (THR) has increased over the last decade. While the relationship between increasing head size and increased stability is well known, the risk of revision with increasing head size remains poorly understood. The aim of this study was to compare the outcome of total hip joint replacement with 32-mm and 36-mm heads. METHODS We carried out a 20-year retrospective analysis of prospective data from the New Zealand Joint Registry (NZJR). All primary total hip replacements registered between January 1999 and December 2018 were included. We compared the rate of revision of 32-mm and 36-mm heads in THR. Sub-group analysis included comparisons of bearing type and all-cause revision. RESULTS 60,051 primary THRs met our inclusion criteria. The revision rate per 100 component years was significantly higher with a 36-mm head than with a 32-mm head (0.649 vs. 0.534, p < 0.001). Subgroup analysis of bearing type showed no significant differences in revision rates for all combinations of 36-mm heads when compared to 32-mm (p = 0.074-0.92), with the exception of metal-on-metal (MoM); p = 0.038. When MoM was removed there was no significant difference in revision rates per 100 component years between 32-mm and 36-mm heads, 0.528 versus 0.578 (p = 0.099). CONCLUSIONS Increasing head size from 32 mm to 36 mm results in no significant increase in revision in all bearing combinations except MoM.
Collapse
Affiliation(s)
- Robert Tr English
- Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand
| | - Jacob T Munro
- Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand
- University of Auckland, New Zealand
| | - Andrew P Monk
- Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand
- University of Auckland, New Zealand
| |
Collapse
|
4
|
Savin L, Pinteala T, Mihai DN, Mihailescu D, Miu SS, Sirbu MT, Veliceasa B, Popescu DC, Sirbu PD, Forna N. Updates on Biomaterials Used in Total Hip Arthroplasty (THA). Polymers (Basel) 2023; 15:3278. [PMID: 37571172 PMCID: PMC10422432 DOI: 10.3390/polym15153278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 07/30/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient's quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.
Collapse
Affiliation(s)
- Liliana Savin
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Tudor Pinteala
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Dana Nicoleta Mihai
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
- Department of Protheses Technology, Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Dan Mihailescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Smaranda Stefana Miu
- Department of Rehabilitation, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Mihnea Theodor Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Bogdan Veliceasa
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Dragos Cristian Popescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Paul Dan Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Norin Forna
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| |
Collapse
|
5
|
Bian Y, Wang H, Huang A. Finite Element Analysis of Acetabulum Prosthesis' Lining Damage Zone with Different Implanting Angle. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2023; 2023:9350474. [PMID: 37304323 PMCID: PMC10256448 DOI: 10.1155/2023/9350474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 03/13/2023] [Accepted: 03/20/2023] [Indexed: 06/13/2023]
Abstract
Objective Research the acetabular component's construction method of a three-dimensional finite element model in THA with different angles and study the influence of polyethylene liner wearing with finite element analysis. Methods Build a model in the 3D modeling software system HyperMesh according to the artificial hip joint prosthesis' entities and data. Using a finite element analysis system, ABAQUS 6.11 reconstitute acetabular prosthesis after hip replacement joints under different implanting position angles. Simulation and load the joint load when sheet foot touchdown state. Calculate the plastic volume strain and fatigue fracture. Results The two groups of combinations of abduction angle 50° vs. anteversion angle 10° and abduction angle 55° vs. anteversion angle 15° have been found to have relatively smaller interface plastic strain and fatigue fracture volume value (2.241 × 10-7 m3, 2.443 × 10-7 m3), respectively. Conclusion The groups of combinations of abduction angle 50° vs. anteversion angle 10° have been found to have relatively smallest interface plastic strain and fatigue fracture volume value in the total hip arthroplasty.
Collapse
Affiliation(s)
| | - Hao Wang
- Liaocheng Traditional Chinese Medicine Hospital, China
| | | |
Collapse
|
6
|
Almaawi A, Alzuhair A, AlHakbani A, Benfaris D, Al-Abdullatif F, Alabdulkarim NH, Awwad W. Comparison of Ceramic-on-Ceramic and Ceramic-on-Highly-Crosslinked-Polyethylene in Primary Total Hip Arthroplasty: Findings of a Meta-Analysis. Cureus 2021; 13:e13304. [PMID: 33738155 PMCID: PMC7958929 DOI: 10.7759/cureus.13304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Introduction An optimal hip implant is biocompatible, durable, and resistant to chemical and mechanical wear. This analysis aimed to compare failure (revision) and complication rates between ceramic-on-ceramic (CoC) and ceramic-on-highly-crosslinked-polyethylene (CoHXLPE) implants. Methods This review comprised of scientific literature published between 1995 and 2019. We included randomized controlled trials in adults (>18 years) that presented results of CoC and CoHXLPE total hip arthroplasty (THA) with more than two years of mean follow-up and drafted in English. The primary outcomes for this analysis were complications, revision rates, and loosening rates. Results Eight studies (1,689 hips) were included in this systematic review. There was no significant differences between COC and CoHXLPE for the risk of post-surgical complications (relative risk [RR]: 1.98, 95% confidence interval [CI]: 0.83-4.69, P = 0.12). Revision rates (RR: 1.25, 95% CI: 0.71-2.20, P = 0.43] and loosening rates between the two implants were not significantly different (RR: 1.17, 95% CI: 0.30-4.52, P = 0.82). Conclusion We report no significant differences between CoHXLPE and CoC in adults undergoing primary THA. Although introduced relatively recently, CoHXLPE is a cost-effective bearing that can be used for younger patients with no risk of increased complications in comparison to CoC. Further studies with longer follow-up periods are recommended to confirm the findings of this meta-analysis.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Waleed Awwad
- Orthopaedic Surgery, King Saud University, Riyadh, SAU
| |
Collapse
|
7
|
Fernández-Fairén M, Torres-Perez A, Perez R, Punset M, Molmeneu M, Ortiz-Hernández M, Manero JM, Gil J. Early Short-Term Postoperative Mechanical Failures of Current Ceramic-on-Ceramic Bearing Total Hip Arthroplasties. MATERIALS 2020; 13:ma13235318. [PMID: 33255355 PMCID: PMC7727787 DOI: 10.3390/ma13235318] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/19/2020] [Accepted: 11/20/2020] [Indexed: 12/01/2022]
Abstract
Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.
Collapse
Affiliation(s)
- Mariano Fernández-Fairén
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
| | - Ana Torres-Perez
- Hospital Universitario Santa Lucía, Calle Mezquita, s/n, 30202 Cartagena, Spain;
| | - Roman Perez
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
| | - Miquel Punset
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
- UPC Innovation and Technology Center (CIT-UPC), Technical University of Catalonia (UPC), C. Jordi Girona 3–1, 08034 Barcelona, Spain
| | - Meritxell Molmeneu
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - Monica Ortiz-Hernández
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - José María Manero
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - Javier Gil
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
- Correspondence:
| |
Collapse
|
8
|
Mei XY, Gong YJ, Safir O, Gross A, Kuzyk P. Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature. Can J Surg 2020; 62:249-258. [PMID: 31348632 DOI: 10.1503/cjs.013118] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Background Total hip arthroplasty (THA) is increasingly performed in younger patients despite the lack of comprehensive assessment of long-term outcomes. We systematically reviewed the contemporary literature to assess the 1) indications, 2) implant selection and long-term survivorship, 3) complication and reoperation rates and 4) radiographic and functional outcomes of primary THA in patients younger than 55 years. Methods We searched the Embase and MEDLINE databases for English-language articles published between 2000 and 2018 that reported outcomes of primary THA in patients younger than 55 years with a minimum follow-up duration of 10 years. Results Thirty-two studies reporting on 3219 THA procedures performed in 2434 patients met our inclusion criteria. The most common preoperative diagnoses were avascular necrosis (1044 [32.4%]), osteoarthritis (870 [27.0%]) and developmental dysplasia of the hip (627 [19.5%]). Modular implants (3001 [93.2%]), cementless fixation (2214 [68.8%]) and metal-on-polyethylene bearings (1792 [55.7%]) were frequently used. The mean 5- and 10-year survival rates were 98.7% and 94.6%, respectively. Data on survival beyond 10 years were heterogeneous, with values of 27%–99.5% at 10–14 years, 59%–84% at 15–19 years, 70%–77% at 20–24 years and 60% at 25–30 years. Rates of dislocation, deep infection and reoperation for any reason were 2.4%, 1.2% and 16.3%, respectively. The mean Harris Hip Score improved from 43.6/100 to 91.0/100. Conclusion Total hip arthroplasty in patients younger than 55 years provides reliable outcomes at up to 10 years. Future studies should evaluate the outcomes of THA in this population at 15–20 years’ follow-up.
Collapse
Affiliation(s)
- Xin Yu Mei
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Ying Jia Gong
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Oleg Safir
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Allan Gross
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Paul Kuzyk
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| |
Collapse
|
9
|
Qin Y, Zhou Z. [Research progress of total hip arthroplasty for patients with sequelae of suppurative hip arthritis]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:139-144. [PMID: 31939249 DOI: 10.7507/1002-1892.201905083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Objective To summarize the research progress of total hip arthroplasty (THA) in treatment of sequelae of suppurative hip arthritis. Methods The relevant literature was systematically searched and the operation timing, treatments of acetabular and femoral sides, and prosthesis selection in THA for sequelae of suppurative hip arthritis were summarized. Results THA is an effective way to treat the sequelae of suppurative hip arthritis. In order to avoid the recurrence of infection, THA is recommended to be performed after 10 years of resting period of hip septic infection. These patients may have acetabulum dysplasia and poor coverage of acetabulum. When performing THA, high position acetabulum, osteotomy of the medial acetabular wall, structural bone graft, Cage, tantalum augment, or three-dimensional printing prosthesis can be chosen. The femoral side may has small medullary cavity, increased femoral neck anteversion, increased femoral neck-stem angle, extend trochanter, and poor bone mass. When performing THA, the femoral osteotomy and appropriate prosthesis can be selected for treatment. The patients with sequelae of suppurative hip arthritis are mostly young, cementless THA is preferred for a better long-term survivorship. Conclusion THA is an effective method for the sequelae of suppurative hip arthritis, but the operation is difficult and has relative high complication rate. Surgeons should have full understanding.
Collapse
Affiliation(s)
- Yongzhi Qin
- Department of Orthopedics, the People's Hospital of Guang'an City, Guangan Sichuan, 638000, P.R.China
| | - Zongke Zhou
- Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041,
| |
Collapse
|
10
|
Rankin CS, Robinson PG, Beattie N, Gaston P. Fracture of a BIOLOX Delta Ceramic Femoral Head: A Case Report and Update of the Literature. JBJS Case Connect 2019; 9:e0336. [PMID: 31592818 DOI: 10.2106/jbjs.cc.18.00336] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
CASE A 52-year-old man underwent right total hip replacement with a 32-mm BIOLOX delta ceramic head with a polyethylene liner. At 8 months, he fell onto his right hip. Radiographs at the time were unremarkable. One month later, he noticed a sharp pain and a sensation of grinding in his right hip; radiographs of the hip showed a fracture of the ceramic head. CONCLUSIONS This case further demonstrates that fourth-generation ceramic heads can fracture, and delays in catastrophic failure of ceramics in total hip arthroplasty (THA) following trauma may be secondary to the "slow crack growth" hypothesis.
Collapse
Affiliation(s)
| | - P G Robinson
- Department of Trauma and Orthopaedic Surgery, Royal Infirmary of Edinburgh, United Kingdom
| | - N Beattie
- Department of Trauma and Orthopaedic Surgery, Royal Infirmary of Edinburgh, United Kingdom
| | - P Gaston
- Department of Trauma and Orthopaedic Surgery, Royal Infirmary of Edinburgh, United Kingdom
| |
Collapse
|
11
|
Malahias MA, De Martino I, Gu A, Baral E, Wright TM, Sculco PK. Complete wear-through of a metal-backed acetabular cup in an ambulatory patient. Arthroplast Today 2019; 5:394-400. [PMID: 31886378 PMCID: PMC6920715 DOI: 10.1016/j.artd.2019.09.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/17/2019] [Accepted: 09/27/2019] [Indexed: 01/20/2023] Open
Abstract
We present a rare case of a patient who presented with complete and rapid wear-through of a ceramic femoral head through a polyethylene liner and titanium acetabular cup. In addition, this patient exhibited significantly elevated serum titanium ion levels, which may serve as a marker of severe metallosis in cases where the preoperative plain radiographs underestimate signs of periarticular metal debris. The unique findings of this case include the rapid (less than 1 year time) wear-through of the femoral head in interval radiographs and the dramatic progression of metallosis and pelvic and femoral osteolysis that required both component revision. In addition, the markedly elevated titanium levels secondary to cup wear-through are also of interest and demonstrate a systemic manifestation of abrasive wear of a titanium alloy component.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Ivan De Martino
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Alex Gu
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Elexis Baral
- Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA
| | - Peter K Sculco
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
12
|
Chatterjee S, Kobylinski S, Basu B. Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone. J Biomech Eng 2019; 140:2681672. [PMID: 30029239 DOI: 10.1115/1.4040249] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Indexed: 11/08/2022]
Abstract
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene-20% hydroxyapatite-20% alumina (HDPE-20%HA-20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India
| | - Sabine Kobylinski
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Technical University of Applied Sciences Regensburg (OTH Regensburg), Regensburg 93047, Germany
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India e-mails:
| |
Collapse
|
13
|
Kurokawa H, Taniguchi A, Morita S, Takakura Y, Tanaka Y. Total ankle arthroplasty incorporating a total talar prosthesis. Bone Joint J 2019; 101-B:443-446. [DOI: 10.1302/0301-620x.101b4.bjj-2018-0812.r2] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Aims Total ankle arthroplasty (TAA) has become the most reliable surgical solution for patients with end-stage arthritis of the ankle. Aseptic loosening of the talar component is the most common complication. A custom-made artificial talus can be used as the talar component in a combined TAA for patients with poor bone stock of the talus. The purpose of this study was to investigate the functional and clinical outcomes of combined TAA. Patients and Methods Ten patients (two men, eight women; ten ankles) treated using a combined TAA between 2009 and 2013 were matched for age, gender, and length of follow-up with 12 patients (one man, 11 women; 12 ankles) who underwent a standard TAA. All had end-stage arthritis of the ankle. The combined TAA features a tibial component of the TNK ankle (Kyocera, Kyoto, Japan) and an alumina ceramic artificial talus (Kyocera), designed using individualized CT data. The mean age at the time of surgery in the combined TAA and standard TAA groups was 71 years (61 to 82) and 75 years (62 to 82), respectively. The mean follow-up was 58 months (43 to 81) and 64 months (48 to 88), respectively. The outcome was assessed using the Japanese Society for Surgery of the Foot (JSSF) ankle-hindfoot scale, the Ankle Osteoarthritis Scale (AOS), and the Self-Administered Foot Evaluation Questionnaire (SAFE-Q). Results The mean preoperative JSSF score of the combined TAA and standard TAA groups was 44 (sd 11) and 49 (sd 10), respectively. The mean postoperative JSSF scores were 89 (sd 6.1) and 72 (sd 15), respectively. The mean postoperative JSSF score of the combined TAA group was significantly higher (p = 0.0034). The mean preoperative AOS scores for pain and function in the combined TAA and standard TAA groups were 5.8 (sd 3.3) and 5.5 (sd 3.1), and 8.6 (sd 1.3), and 7.1 (sd 2.9), respectively. The mean postoperative AOS scores of pain and function were 2.5 (sd 2.5) and 2.2 (sd 1.9), and 2.5 (sd 3.3) and 3.4 (sd 2.9), respectively. There were no significant differences between the two groups in terms of postoperative AOS scores. The mean postoperative SAFE-Q scores were: for pain, 76 (sd 23) and 70 (sd 23); for physical function, 66 (sd 25) and 55 (sd 27); for social function, 73 (sd 35) and 62 (sd 34); for shoe-related, 73 (sd 19) and 65 (sd 26); and for general health, 78 (sd 28) and 67 (sd 29), respectively. There were no significant differences between the two groups in terms of postoperative SAFE-Q scores. Conclusion Combined TAA resulted in better clinical results than standard TAA. Cite this article: Bone Joint J 2019;101-B:443–446.
Collapse
Affiliation(s)
- H. Kurokawa
- Department of Orthopaedic Surgery, Nara Medical University, Nara, Japan
| | - A. Taniguchi
- Department of Orthopaedic Surgery, Nara Medical University, Nara, Japan
| | - S. Morita
- Department of Orthopaedic Surgery, Nara Medical University, Nara, Japan
| | - Y. Takakura
- Department of Orthopaedic Surgery, Nara Medical University, Nara, Japan
| | - Y. Tanaka
- Department of Orthopaedic Surgery, Nara Medical University, Nara, Japan
| |
Collapse
|
14
|
Moura DL, Fonseca FP. SPORTS ACTIVITY AND HIP, KNEE, SHOULDER AND INTERVERTEBRAL DISC ARTHROPLASTIES. ACTA ORTOPEDICA BRASILEIRA 2018; 26:350-355. [PMID: 30464721 PMCID: PMC6220666 DOI: 10.1590/1413-785220182605182508] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The success of joint replacement surgery has been responsible for raising patients' expectations regarding the procedure. Many of these procedures are currently designed not only to relive the pain caused by arthrosis, but also to enable patients to achieve functional recovery and to engage in some degree of physical activity and sports. However, as physical exercise causes an increase in forces exercised through the articular prosthesis, it can be an important risk factor for its early failure. Scientific literature on sports after arthroplasty is limited to small-scale retrospective studies with short-term follow-up, which are mostly insufficient to evaluate articular prosthesis durability. This article presents a review of the literature on sports in the context of hip, knee, shoulder and intervertebral disc arthroplasty, and puts forward general recommendations based on the current scientific evidence. Systematic Review, Level of Evidence III.
Collapse
Affiliation(s)
- Diogo Lino Moura
- Universitário de Coimbra, Portugal; University of Coimbra, Portugal
| | | |
Collapse
|
15
|
Abstract
INTRODUCTION We have investigated the revision rates of all bearing surface combinations for primary total hip replacement (THR) registered on the New Zealand Joint Registry (NZJR) to determine which coupling has been the most durable and successful over the last 16 years. METHODS There were 106,139 primary THRs registered, resulting in 4,960 revisions for any cause. We examined all-cause revision rates, reasons for revision and performed survival analyses. RESULTS Ceramic-on-highly cross-linked polyethylene (CoPx) had the lowest all-cause revision rate of 0.54/100-component-years (cys) (95% confidence interval 0.48 to 0.61). This was superior to all other hard-on-soft bearing combinations in unadjusted analysis. Furthermore, the age of patients receiving CoPx was significantly lower than for metal-on-polyethylene (mean 62.9; standard deviation [SD] 10.1 vs. 69.1; SD 9.6; p<0.001). Acetabular loosening was the reason for revision in 14.5% of CoPx, compared to 33% of MoP THRs (p<0.001). Metal-on-metal bearings had the highest revision rate of 1.43/100 cys and were significantly inferior to CoPx (p<0.001). Kaplan-Meier analysis and Cox regression analyses were performed and we adjusted the analyses to control for age, femoral head size, surgical approach and fixation. CONCLUSIONS CoPx remained the most durable and successful coupling used in primary THR in New Zealand irrespective of age, gender or size of femoral head.
Collapse
|
16
|
Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population. J Arthroplasty 2018; 33:1826-1832. [PMID: 29510952 DOI: 10.1016/j.arth.2018.01.066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/18/2018] [Accepted: 01/25/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population. METHODS We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively. RESULTS We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096). CONCLUSIONS MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.
Collapse
|
17
|
Mueller U, Braun S, Schroeder S, Schroeder M, Sonntag R, Jaeger S, Kretzer JP. Influence of humeral head material on wear performance in anatomic shoulder joint arthroplasty. J Shoulder Elbow Surg 2017; 26:1756-1764. [PMID: 28689828 DOI: 10.1016/j.jse.2017.05.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 05/03/2017] [Accepted: 05/08/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND The number of total shoulder arthroplasties has increased in the past years, with encouraging results. However, the survival of anatomic total shoulder arthroplasty (aTSA) is lower compared with that of knee and hip replacements. Wear-associated problems like loosening are well-known causes of long-term failure of aTSA. The main purpose of this study was to investigate the wear behavior of ceramic-polyethylene bearings compared with the standard metal-polyethylene bearings. Because there is a lack of valid experimental wear testing methods, the secondary aim was to develop a validated wear simulation. METHODS The wear assessment was performed using a force-controlled joint simulator for 3 × 106 cycles, and polyethylene wear was assessed gravimetrically and by particle analysis. Kinetic and kinematic data were adopted from in vivo loading measurements and from several clinical studies on shoulder joint kinematics. The reaction of the rotator cuff was simulated on the basis of a virtual soft tissue model. As activity, an abduction-adduction motion of 0°-90° lifting a load of 2 kg superimposed by an anteversion-retroversion has been chosen. RESULTS The studied aTSA resulted in a polyethylene wear rate of 62.75 ± 1.60 mg/106 cycles in combination with metallic heads. The ceramic heads significantly reduced the wear rate by 26.7% to 45.99 ± 1.31 mg/106. There were no relevant differences in terms of the particle characteristics. CONCLUSION This is the first study that experimentally studied the wear behavior of aTSA based on patient-related and biomechanical data under load-controlled conditions. Regarding polyethylene wear, the analyzed aTSA could benefit from ceramic humeral heads.
Collapse
Affiliation(s)
- Ulrike Mueller
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Steffen Braun
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Mark Schroeder
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany.
| |
Collapse
|
18
|
Greber EM, Pelt CE, Gililland JM, Anderson MB, Erickson JA, Peters CL. Challenges in Total Hip Arthroplasty in the Setting of Developmental Dysplasia of the Hip. J Arthroplasty 2017; 32:S38-S44. [PMID: 28291651 DOI: 10.1016/j.arth.2017.02.024] [Citation(s) in RCA: 114] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 02/09/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Developmental dysplasia of the hip (DDH) is a recognized cause of secondary arthritis, which may eventually lead to total hip arthroplasty (THA). An understanding of the common acetabular and femoral morphologic abnormalities will aid the surgeon in preparing for the complexity of the surgical case. METHODS We present the challenges associated with acetabular and femoral morphologies that may be present in the dysplastic hip and discuss surgical options to consider when performing THA. In addition, common complications associated with this population are reviewed. RESULTS The complexity of THA in the DDH patient is due to a broad range of pathomorphologic changes of the acetabulum and femur, as well as the diverse and often younger age of these patients. As such, THA in the DDH patient may offer a typical primary hip arthroplasty or be a highly complex reconstruction. It is important to be familiar with all the subtleties associated with DDH in the THA population. The surgeon must be prepared for bone deficiency when reconstructing the acetabulum and should place the component low and medial (at the anatomic hip center), and avoid oversizing the acetabular component. Femoral dysplasia is also complex and variable, and the surgeon must be prepared for different stem choices that allow for decoupling of the metaphyseal stem fit from the implanted stem version. In Crowe III and IV dysplasia, femoral derotation/shortening osteotomy may be required. Many complications associated with THA in the DDH patient may be mitigated with careful planning and surgical technique. CONCLUSION Performed correctly, THA can yield excellent results in this complex patient population.
Collapse
Affiliation(s)
- Eric M Greber
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah
| | | | | | - Mike B Anderson
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah
| | - Jill A Erickson
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah
| | | |
Collapse
|
19
|
Lee JM. The Current Concepts of Total Hip Arthroplasty. Hip Pelvis 2016; 28:191-200. [PMID: 28097108 PMCID: PMC5240313 DOI: 10.5371/hp.2016.28.4.191] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Revised: 12/08/2016] [Accepted: 12/08/2016] [Indexed: 12/15/2022] Open
Affiliation(s)
- Joong-Myung Lee
- Department of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University, Seongnam, Korea
| |
Collapse
|
20
|
National Trends in Primary Total Hip Arthroplasty in Extremely Young Patients: A Focus on Bearing Surface Usage From 2009 to 2012. J Arthroplasty 2016; 31:63-8. [PMID: 27430185 DOI: 10.1016/j.arth.2016.01.061] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 01/21/2016] [Accepted: 01/25/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The ideal bearing surface for primary total hip arthroplasty (THA) in young patients remains a debate. Data on recent national trends are lacking. The purpose of this study is to provide an analysis on the national epidemiologic trends of bearing surface usage in patients aged ≤30 years undergoing THA from 2009 through 2012. METHODS Using the Healthcare Cost and Utilization Project Nationwide Inpatient Sample from 2009 to 2012, 9265 THA discharges (4210 coded by bearing surface) were identified in patients aged ≤30 years. Prevalence of surface type was analyzed along with patient and hospital demographic data. Statistical analysis was performed using SAS (SAS version 9.1; SAS, Inc, Cary, NC). Significance was set at P < .05. RESULTS Ceramic-on-polyethylene (CoP) bearing surfaces were most commonly used, representing 35.6% of cases, followed by metal-on-polyethylene (MoP; 28.0%), metal-on-metal (MoM; 19.3%), and ceramic-on-ceramic (CoC; 17.0%) bearing surfaces. Hard-on-hard bearing surfaces (MoM and CoC) represented only 36.4% of cases, a significant decrease from previously reported findings (2006-2009) where hard-on-hard bearing surfaces were the majority (62.2%; P < .05). Hard-on-hard bearing surface usage decreased from 2009 to 2012 (MoM: 29.7% to 10.2%; CoC: 20.0% to 14.7%), whereas hard-on-soft bearing surface usage (MoP and CoP) increased. CoP bearing surfaces saw the most significant increase from 25.7% in 2009 to 48.2% in 2012. A cost analysis revealed that CoP discharges were associated with higher hospital charges than other surface types, with an average charge of $66,457 (P < .05). CONCLUSION Use of hard-on-hard surfaces has decreased significantly in this population, whereas CoP and MoP surfaces have become increasingly common. Determining the optimal bearing surface for extremely young patients continues to be a challenge for orthopedic surgeons as they weigh the risks and benefits of each.
Collapse
|
21
|
Manzano G, Levin RAC, Mayor MB, Schwarzkopf R. Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty. J Orthop Case Rep 2016; 4:51-6. [PMID: 27298960 PMCID: PMC4719376 DOI: 10.13107/jocr.2250-0685.168] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied extensively, however, only few reports have described its catastrophic wear. We report such a case of complete wear of the acetabular liner in a ceramic-on-polyethylene prosthesis in a 57-year adult male. Case Report: A 57-year adult male with a history of bilateral total hip arthroplasty presented to our institution with bilateral hip pain worst on the right. Range of motion was limited by pain on the right hip at the extremes of motion. Radiographs revealed severe osteolysis, heterotopic ossification, complete wear of the acetabular liner, bony impingement of the femoral greater trochanter on the acetabular rim and superior migration of the femoral head. All findings were confirmed intraoperatively. Revision of the acetabular components was performed, which successfully alleviated the patient’s symptoms. Conclusion: Failure of the ceramic-on-polyethylene liner in our patient is due to the use of a non-cross linked polyethylene liner, a highly active lifestyle, and poor follow up. Arthroplasty surgeons should be aware of this complication especially in highly active patients with a conventional polyethylene liner and chronic hip pain.
Collapse
Affiliation(s)
- Givenchy Manzano
- Department of Orthopaedic Surgery, University of California Irvine Medical Center
| | - Rayna A C Levin
- Dartmouth Biomedical Engineering Center, Thayer School of Engineering, Dartmouth College
| | - Michael B Mayor
- Dartmouth Biomedical Engineering Center, Thayer School of Engineering, Dartmouth College
| | - Ran Schwarzkopf
- Department of Orthopaedic Surgery, University of California Irvine Medical Center
| |
Collapse
|
22
|
A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty. Hip Int 2016; 21:176-86. [PMID: 21484744 DOI: 10.5301/hip.2011.6527] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/18/2011] [Indexed: 02/04/2023]
Abstract
We performed a study to assess whether different bearing materials have an impact on femoral bone remodeling within the first four years after a hybrid total hip arthroplasty. 205 of 300 patients were available for 4 years follow-up after being randomly allocated to four prosthetic combinations: A: Zirconia ceramic head, polyethylene cup; B: Cobalt-Chrome-Molybdenum head and cup; C: Zirconia ceramic head, polyethylene moulded on the Titanium shell of the Asian cup; D: Alumina head and cup. Bone mineral density (BMD) was measured with Dual-Energy X-ray Absorptiometry in seven Gruen zones adjacent to the femoral implant. Scans were performed within one week after surgery and four years postoperatively. Clinical outcomes were monitored using the Oxford Hip Score (OHS). A high proportion of patients from group D were excluded due to re-operations (19 patients). BMD decreased significantly in all Gruen zones with the largest declines in group D. BMD changes in Gruen zones 1, 2, 3, 6, and 7 correlated with height, and body weight. Advanced age was associated with an increase in bone loss in Gruen zones 1, 2, 3, 6, and 7. A large stem size was associated with a decline in BMD in Gruen zones 1, 6, and 7.Bone remodeling after total hip arthroplasty may depend on the composition of bearing materials, but age, height, weight, and stem size are also related to changes in BMD.
Collapse
|
23
|
Is a ceramic-on-ceramic bearing really superior to ceramic-on-polyethylene for primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials. Hip Int 2016; 25:191-8. [PMID: 25684252 DOI: 10.5301/hipint.5000223] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/13/2014] [Indexed: 02/05/2023]
Abstract
INTRODUCTION The outcomes of using a ceramic-on-ceramic (CoC) vs ceramic-on-polyethylene (CoP) bearing surface for primary total hip arthroplasty (THA) are much debated. We performed a systematic review and meta-analysis of randomised controlled trials (RCTs) to compare and evaluate the outcomes of these 2 bearing surfaces. MATERIALS AND METHODS Electronic databases (PubMed/Medline, CENTRAL, Embase and Web of Science) were systematically searched for RCTs investigating the association between bearing surfaces and outcomes following primary THA. Two investigators independently reviewed studies for eligibility, assessed the risk of bias, extracted and analysed the data. RESULTS In total, 13 RCTs including a total of 2,488 THAs were identified. The Harris Hip Score appeared to be similar between CoC and CoP THAs. The acetabular liner wear rate was lower in CoC than CoP THA, but the meta-analysis showed that the incidence of component-related noise and overall ceramic fracture in CoC group were 14.73 times and 6.02 times higher than CoP THA, respectively. There were no statistically significant differences in rates of radiolucent line formation (>1 mm), osteolysis, loosening, revision with follow-up ≥ 5 years, intraoperative femoral fracture, dislocation, deep infection, deep venous thrombosis and leg length discrepancy between CoC and CoP THAs. CONCLUSIONS There appears to be no clear evidence favouring the use of either a CoC or CoP bearing surfaces in primary THA, further studies with high-quality and longer term follow-up to provide more evidence on this topic are still required.
Collapse
|
24
|
Karidakis GK, Karachalios T. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Clin Orthop Relat Res 2015; 473:3836-45. [PMID: 26290343 PMCID: PMC4626474 DOI: 10.1007/s11999-015-4503-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. QUESTIONS/PURPOSES The purpose of this study was to investigate in vivo whether the combination of an oxidized zirconium femoral head on XLPE produces less wear than a ceramic head on XLPE or a ceramic head on conventional polyethylene (CPE) couplings and whether any of these bearing combinations results in higher hip scores. METHODS Between 2003 and 2007, we performed 356 total hip arthroplasties in 288 patients; of those, 199 (69.1%) patients (199 hips) were enrolled in what began as a randomized trial. Unfortunately, after the 57(th) patient, the randomization process was halted because of patients' preference for the oxidized zirconium bearing instead of the ceramic after (as they were informed by the consent form), and after that, alternate allocation to the study groups was performed. Hips were allocated into four groups: in Group A, a 28-mm ceramic head on CPE was used; in Group B, a 28-mm ceramic head on XLPE; in Group C, a 28-mm Oxinium head on XLPE; and in Group D, a 32-mm Oxinium head on XLPE. The authors prospectively collected in vivo wear data (linear wear, linear wear rate, volumetric wear, and volumetric wear rate) using PolyWare software. Preoperative and postoperative clinical data, including Harris and Oxford hip scores, were also collected at regular intervals. Of those patients enrolled, 188 (95%) were available for final followup at a minimum of 7 years (mean, 9 years; range, 7-12 years). RESULTS All bearing surfaces showed a varying high bedding-in effect (plastic deformation of the liner) up to the second postoperative year. At 5 years both oxidized zirconium on XLPE groups showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 310 ± 55-206 ± 55 mm(3)/year, Group D: 320 ± 58-205 ± 61 mm(3)/year) when compared with ceramic on CPE (Group A: 791 ± 124-306 ± 85 mm(3)/year) and ceramic on XLPE (Group B: 1420 ± 223-366 ± 88 mm(3)/year) groups. For those patients who had completed 10 years of followup (20 patients [44.5%] of Group A, 21 [45.7%] of Group B, 23 [47.9%] of Group C, and 22 [44.9%] of Group D), at 10 years, both oxidized zirconium on XLPE groups also showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 356 ± 64 to 215 ± 54 mm(3)/year, Group D: 354 ± 50 to 210 ± 64 mm(3)/year) when compared with ceramic on CPE (Group A: 895 ± 131 to 380 ± 80 mm(3)/year) and ceramic on XLPE (Group B: 1625 ± 253 to 480 ± 101 mm(3)/year) groups. When wear rates of both oxidized zirconium groups were compared, no differences were found at any time interval with the numbers available. Two hips (one from Group A and one from Group B) are scheduled for revision as a result of wear and osteolysis. There were no differences in hip scores among the groups with the numbers available. CONCLUSIONS In this study, in vivo wear parameters were lower when the combination of an oxidized zirconium head on XLPE liner was used at an average of 9 years (range, 7-12 years) followup. Further larger-scale clinical studies should confirm these findings and evaluate osteolysis and revision rates in association with the use of this bearing coupling. LEVEL OF EVIDENCE Level II, therapeutic study.
Collapse
Affiliation(s)
- George K. Karidakis
- Orthopaedic Department, Faculty of Medicine, School of Health Sciences, University of Thessalia, University General Hospital of Larissa, Larissa, Hellenic Republic
| | - Theofilos Karachalios
- Orthopaedic Department, Faculty of Medicine, School of Health Sciences, University of Thessalia, University General Hospital of Larissa, Larissa, Hellenic Republic
| |
Collapse
|
25
|
Garvin KL, White TC, Dusad A, Hartman CW, Martell J. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years. Clin Orthop Relat Res 2015; 473:3829-35. [PMID: 26122983 PMCID: PMC4626518 DOI: 10.1007/s11999-015-4422-7] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Patients 50 years or younger are at high risk for wear-related complications of their total hip arthroplasty (THA) because of their generally higher levels of activity. Highly crosslinked polyethylene (HXLPE) is believed to be more durable for this population than conventional polyethylene because of its improved wear; however, limited information is available on the wear of HXLPE in this population, particularly the wear of HXLPE when it articulates with alternative bearings like Oxinium (Smith & Nephew, Memphis, TN, USA). QUESTIONS/PURPOSES The purpose of this study was to evaluate two questions relative to this population of patients undergoing THA. First, what was the linear and volumetric wear rate of HXLPE in patients 50 years or younger at a minimum followup of 9 years and was osteolysis observed in any of these hips? Given the potential for damage to the Oxinium femoral head surface, was the wear of HXLPE in the patients with this material similar to the other bearings or was there accelerated or runaway wear that was visible in any of the patients? METHODS From November 1999 to April 2005, 105 THAs were performed in 95 patients 50 years of age or younger (mean, 42 years; range, 20-50 years). The mean body mass index was 30 kg/m(2) (range, 17-51 kg/m(2)).The mean followup was 12 years (range, 9-14 years). Two patients died, five patients (one bilateral) were lost to followup, and one hip was revised elsewhere for pain. The patients' information was not included in the study, which left 87 patients with 96 hips for analysis. Highly crosslinked polyethylene was the acetabular bearing for all of the hips. We analyzed the linear and volumetric wear of all of the hips using the Martell method. Eighty hips had the same diameter head (28 mm) allowing us to more accurately compare the different bearing materials. The type of femoral head used was related to our sequential use of materials beginning with cobalt chrome (14), ceramic (23) followed by Oxinium (43) in the hips with 28-mm heads. Although cobalt-chrome was used early in this study, our previous experience with ceramic on polyethylene encouraged us to use it as an alternative bearing. The Oxinium was used consecutively for the remaining hips. RESULTS The mean wear of the HXLPE after 1 year of bedding-in (true linear wear)was 0.022 mm/year (95% confidence interval [CI], 0.015-0.030 mm/year). The mean volumetric wear of HXLPE after 1 year of bedding-in (true volumetric wear) was 9 mm(3)/year (95% CI, 4-14 mm(3)/year). None of the hip radiographs had evidence of loosening or osteolysis. Wear was not associated with femoral head material (p = 0.58 for linear wear/year versus head material and p = 0.52 for volumetric wear/year versus head material). CONCLUSIONS In our study of patients 50 years of age or younger undergoing THA, the linear and volumetric wear rates of HXLPE were very low regardless of the bearing surface material. The laboratory concerns of Oxinium surface damage are serious but at this time we have not seen high wear of the HXLPE or osteolysis in this population. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Kevin L. Garvin
- />Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, 981080 Nebraska Medical Center, Omaha, NE 68198-1080 USA
| | - Tyler C. White
- />Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, 981080 Nebraska Medical Center, Omaha, NE 68198-1080 USA
| | - Anand Dusad
- />Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, 981080 Nebraska Medical Center, Omaha, NE 68198-1080 USA
| | - Curtis W. Hartman
- />Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, 981080 Nebraska Medical Center, Omaha, NE 68198-1080 USA
| | - John Martell
- />The Orthopaedic Research Institute, University of Chicago Medicine, Chicago, IL USA
| |
Collapse
|
26
|
Schwartsmann1 CR, Spinelli LDF, Boschin LC, Yépez AK, Crestani MV, Silva MF. Correlation between patient age at total hip replacement surgery and lifeexpectancy. ACTA ORTOPEDICA BRASILEIRA 2015; 23:323-5. [PMID: 27057147 PMCID: PMC4775511 DOI: 10.1590/1413-785220152306148609] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Total hip arthroplasty (THA) is one of the most cost-effective hip surgeries among orthopedic procedures. We conducted an extensive literature review with 5,394 papers regarding survival rates after THA. We searched PubMed, Embase and the Cochrane library from January 1(st), 1970 to July 31(th), 2014 looking for all citations about total hip arthroplasty with a long term follow-up (longer than 10 years). The criteria were rigorous: no loss of follow-up, and follow-up more than 10 years. The authors should have known the complete history of patients (whether the patient is alive or dead). Considering the criteria, we found only 15 papers. To evaluate the relationship between follow-up and survival, a linear regression analysis was applied. Considering the papers analysed, and applying the search criteria, we obtained a mean age for the patients above 57.5 years. The chance of survival at 15 years was 57.6%, at 20 years it was 34.6% and at 25 years it is only 11.6%. The relationship between follow-up and survival was significantly linear (p <0.001). Only 11.6% of patients undergoing THA will be still alive 25 years after the surgical procedure. Level of Evidence I, Prognostic Study.
Collapse
|
27
|
Abstract
BACKGROUND The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fractures pose a serious complication which often necessitates major revision surgery. To date, there are no long-term data (>20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. The purpose of this research was to investigate long-term CoP fracture rate. METHODS We evaluated the clinical and radiographic results of 348 cementless THAs treated with 2nd generation Biolox Al₂O₃ Ceramic-on-Polyethylene (CoP) bearings consecutively implanted between January 1985 and December 1989. The mean age at implantation was 57 years. The patients were followed for a minimum of 20 years. At the final 111 had died, and 5 were lost to follow-up. The cumulative incidence of ceramic head fractures in the long-term was estimated using a competing risk analysis. RESULTS The cumulative incidence of ceramic head fracture after 22-years was estimated with a competing risk analysis at 0.29% after 22-years (SE = 2.09%; 95% - CI: 0.03-1.5%). The radiographic analysis revealed no impending failures at final follow-up. DISCUSSION/CONCLUSION The fracture rate of second-generation ceramic heads using a CoP articulation remains very low into the third decade after cementless THA.
Collapse
|
28
|
Two Year Clinical Outcomes of Total Hip Arthroplasty Are Not Dependent on Femoral Head Composition. HSS J 2015; 11:130-5. [PMID: 26140032 PMCID: PMC4481248 DOI: 10.1007/s11420-015-9433-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 01/21/2015] [Indexed: 02/07/2023]
Abstract
BACKGROUND Assessment of clinical outcomes and patient quality of life after total hip arthroplasty continues to grow in importance with the focus on how bearing surfaces affect long-term survival, wear, and cost. Further, as quality measures have become incorporated into reimbursement, there is a need to quantify factors which may influence these outcomes. Currently, there is a paucity of literature regarding the effects of the femoral head composition on clinical outcomes or quality of life. QUESTIONS/PURPOSES We sought to determine if any difference in quality of life measures could be detected in patients treated with total hip replacement implanted with cobalt-chrome (CoCr) versus ceramic femoral heads at 2-year follow-up. METHODS We compared the hip disability and osteoarthritis outcome score (HOOS) and EuroQOL (EQ5D) scores of a matched set of patients that underwent primary total hip arthroplasty with highly cross-linked polyethylene (HXLPE) and a single implant system consisting of either a metal or a ceramic femoral head. RESULTS Clinical outcomes and quality of life improved for both groups after hip replacement surgery. Patients with a ceramic head showed greater improvement than those with a metal head in HOOS pain and EQ5D VAS scores by a statistically significant margin (p = 0.0417 and 0.019, respectively), but the differences between the HOOS and EQ5D VAS scores (3.4 and 0.04, respectively) do not demonstrate a clinically significant difference. CONCLUSIONS We found that the femoral head composition has no effect on clinical outcomes or patient quality of life at 2 years.
Collapse
|
29
|
The case for ceramic-on-polyethylene as the preferred bearing for a young adult hip replacement. Hip Int 2015; 24:421-7. [PMID: 24817396 DOI: 10.5301/hipint.5000138] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/03/2014] [Indexed: 02/04/2023]
Abstract
The optimum choice of bearing surfaces in total hip arthroplasty, particularly in the younger and more active patient, remains controversial. Despite several studies demonstrating good long-term results for the metal-on-polyethylene articulation, there has been a recent vogue towards the utilisation of hard-on-hard bearings for younger patients due, in part, to concerns regarding polyethylene induced osteolysis. However, well-documented complications concerning metal-on-metal bearings and the risk of fracture in ceramic-on-ceramic bearings have raised concerns regarding the principle of the hard-on-hard bearing in the active patient. With recent technological advancements in the manufacture of both polyethylene and alumina ceramics, the in vitro properties of each material with regards to strength and toughness have been significantly improved. In addition, ceramic femoral heads have consistently been shown to produce less in vivo polyethylene wear than similar sized metal heads. This paper aims to critically review the biomechanical, in vivo and clinical studies related to the use of the ceramic on polyethylene bearing, and highlights its potential use as the preferred bearing for a young adult hip replacement.
Collapse
|
30
|
Evaluation of Two Total Hip Bearing Materials for Resistance to Wear Using a Hip Simulator. LUBRICANTS 2015. [DOI: 10.3390/lubricants3020459] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
31
|
Wear Performance of Sequentially Cross-Linked Polyethylene Inserts against Ion-Treated CoCr, TiNbN-Coated CoCr and Al2O3 Ceramic Femoral Heads for Total Hip Replacement. LUBRICANTS 2015. [DOI: 10.3390/lubricants3010014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
32
|
Lübbeke A, Gonzalez A, Garavaglia G, Roussos C, Bonvin A, Stern R, Peter R, Hoffmeyer P. A comparative assessment of small-head metal-on-metal and ceramic-on-polyethylene total hip replacement. Bone Joint J 2014; 96-B:868-75. [PMID: 24986938 DOI: 10.1302/0301-620x.96b7.32369] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen. In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern.
Collapse
Affiliation(s)
- A Lübbeke
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - A Gonzalez
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - G Garavaglia
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - C Roussos
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - A Bonvin
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - R Stern
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - R Peter
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - P Hoffmeyer
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| |
Collapse
|
33
|
Tozun IR, Ozden VE, Dikmen G, Beksac B. Mid-term result of ceramic bearings in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2014; 38:2027-31. [DOI: 10.1007/s00264-014-2387-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Accepted: 05/14/2014] [Indexed: 11/29/2022]
|
34
|
Parsons C, Batson R, Reighard S, Tanner S, Snider B, Pace TB. Clinical outcomes assessment of three similar hip arthroplasty bearing surfaces. Orthop Rev (Pavia) 2014; 6:5334. [PMID: 25002938 PMCID: PMC4083311 DOI: 10.4081/or.2014.5334] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Accepted: 04/18/2014] [Indexed: 12/05/2022] Open
Abstract
This report examines the clinical performance of three very similar total hip arthroplasty designs with distinctly different bearing surfaces used over the course 10-17 years. Clinical outcomes assessments for each group are compared in the context of varying implant related costs related to the latest technology at the time of surgery. Eighty-one surgeries were studied and differ by bearing surface. In this study, 36 hips are ceramic on polyethylene, 27 are metal on polyethylene and 18 are metal on metal. All polyethylene components are nonhighly cross-linked. The ceramic on polyethylene group has younger patients, on average, and higher percentage of patients with significant polyethylene wear. These groups have an average follow-up time of 8.6 years when assessing functional hip scores, thigh pain, groin pain, revision surgeries and radiographic osteolysis. The implant purchasing cost at the time of surgery was assessed to determine if a correlation exists between outcomes and the more technologically advanced implants use at the time of surgery. Based on midterm clinical outcome assessment, no correlation between initial hospital cost and clinical outcomes of one bearing surface over another can be found.
Collapse
Affiliation(s)
| | - Ryan Batson
- University of South Carolina, School of Medicine , Greenville, SC, USA
| | - Shane Reighard
- University of South Carolina, School of Medicine , Greenville, SC, USA
| | | | - Becky Snider
- Department of Orthopedics, Greenville Health System , SC, USA
| | - Thomas B Pace
- University of South Carolina, School of Medicine , Greenville, SC, USA ; Department of Orthopedics, Greenville Health System , SC, USA
| |
Collapse
|
35
|
Hernigou P, Homma Y, Pidet O, Guissou I, Hernigou J. Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation. Clin Orthop Relat Res 2013; 471:3875-82. [PMID: 23423622 PMCID: PMC3825906 DOI: 10.1007/s11999-013-2857-2] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND It is unclear whether late THA dislocations are related to mechanical impingement or to a biological mechanism that decreases the stability provided by the capsule (eg, inflammation secondary to osteolysis). It is also unknown if alumina-on-alumina bearing couples decrease the risk of late dislocation as a result of the absence of wear and osteolysis. QUESTION/PURPOSES We asked (1) whether the cumulative number of dislocations differed with alumina-on-alumina (AL/AL) or alumina-on-polyethylene bearings (AL/PE); (2) whether patient factors (age, sex, and diseases) affect risk of late dislocation; (3) whether mechanical factors (component malposition, penetration resulting from creep and wear) or (4) biologic hip factors at revision (thickness of the capsule, volume of joint fluid removed at surgery, histology) differed with the two bearing couples. METHODS One hundred twenty-six patients (252 hips) with bilateral THA (one AL/AL and the contralateral AL/PE) received the same cemented implants except for the cup PE cup or an AL cup. The cumulative risk of dislocation (first-time and recurrent dislocation) was calculated at a minimum of 27 years. We measured cup position, creep and wear, and capsular thickness in the hips that had revision. RESULTS AL/PE and AL/AL hips differed by the cumulative number of dislocation (31 with AL/PE versus four with AL/AL) and by the number of late dislocations (none with AL/AL, 28 with AL/PE). Cause of osteonecrosis, age, and sex affected the number of dislocations. The frequency of component malposition did not differ between the two bearing couples. The risk of late dislocation appeared less in AL/AL hips with increased capsular thickness (mean, 4.5 mm; range, 3-7 mm) compared with the thinnest (mean, 1.2 mm; range, 0.2-2 mm) capsule of AL/PE hips. CONCLUSIONS AL/AL bearing couples decreased the cumulative risk of dislocation as compared with AL/PE bearing couples.
Collapse
Affiliation(s)
- Philippe Hernigou
- Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, 94010 Creteil, France
| | - Yasuhiro Homma
- Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, 94010 Creteil, France
| | - Olivier Pidet
- Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, 94010 Creteil, France
| | - Isaac Guissou
- Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, 94010 Creteil, France
| | - Jacques Hernigou
- Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, 94010 Creteil, France
| |
Collapse
|
36
|
White PB, Ranawat AS, Ranawat CS. Ceramic-on-polyethylene: The experience of the Ranawat Orthopaedic Center. ACTA ACUST UNITED AC 2013. [DOI: 10.1053/j.sart.2014.01.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Garino JP. The reliability of modern alumina bearings in total hip arthroplasty—Update to a 2006 report. ACTA ACUST UNITED AC 2013. [DOI: 10.1053/j.sart.2014.01.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
38
|
Mantripragada VP, Lecka-Czernik B, Ebraheim NA, Jayasuriya AC. An overview of recent advances in designing orthopedic and craniofacial implants. J Biomed Mater Res A 2013; 101:3349-64. [PMID: 23766134 PMCID: PMC4854641 DOI: 10.1002/jbm.a.34605] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 01/11/2013] [Accepted: 01/11/2013] [Indexed: 01/22/2023]
Abstract
Great deal of research is still going on in the field of orthopedic and craniofacial implant development to resolve various issues being faced by the industry today. Despite several disadvantages of the metallic implants, they continue to be used, primarily because of their superior mechanical properties. In order to minimize the harmful effects of the metallic implants and its by-products, several modifications are being made to these materials, for instance nickel-free stainless steel, cobalt-chromium and titanium alloys are being introduced to eliminate the toxic effects of nickel being released from the alloys, introduce metallic implants with lower modulus, reduce the cost of these alloys by replacing rare elements with less expensive elements etc. New alloys like tantalum, niobium, zirconium, and magnesium are receiving attention given their satisfying mechanical and biological properties. Non-oxide ceramics like silicon nitride and silicon carbide are being currently developed as a promising implant material possessing a combination of properties such as good wear and corrosion resistance, increased ductility, good fracture and creep resistance, and relatively high hardness in comparison to alumina. Polymer/magnesium composites are being developed to improve mechanical properties as well as retain polymer's property of degradation. Recent advances in orthobiologics are proving interesting as well. This paper thus deals with the latest improvements being made to the existing implant materials and includes new materials being introduced in the field of biomaterials.
Collapse
|
39
|
Abstract
Total hip arthroplasty is an effective treatment option for advanced hip arthritis in elderly patients. Studies in young patients have traditionally shown less durable results. With current implants, surgical technique, and cementless fixation methods, the durability of total hip arthroplasty may now be related to the wear performance of the bearing surfaces. To improve implant longevity, there are several bearing surface choices currently available for this demanding group of patients. Alternatives must be evaluated in terms of the risks and benefits associated with each articulation, and all new technologies must be carefully monitored over the long term.
Collapse
|
40
|
A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2013; 37:2131-7. [PMID: 23912267 DOI: 10.1007/s00264-013-2036-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Accepted: 07/16/2013] [Indexed: 12/24/2022]
Abstract
PURPOSE Very few studies have compared alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings in the same patient. The purpose of this prospective randomised study was to compare the clinical and radiographic results and the prevalence of osteolysis in cementless total hip arthroplasty using an alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings in young active patients. METHODS We prospectively compared the results of 100 patients (200 hips) who had undergone a cementless total hip arthroplasty with an alumina-on-alumina ceramic bearing in one hip and an alumina-on-highly cross-linked polyethylene in the other. There were 66 men and 34 women with a mean age of 45.3 years (range, 21-49 years) at the time of surgery. The mean follow-up was 12.4 years (range, 11-13 years). The patients were assessed clinically and radiographically at three months, one year, and annually thereafter. RESULTS Harris hip, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores did not show statistically significant differences between the two groups of bearings preoperatively or at the time of final follow-up. Radiographic findings of the component were not significantly different between the two groups. The mean polyethylene linear penetration was 0.031 ± 0.004 mm per year. No hips in either group displayed osteolysis. The Kaplan-Meier survivorship with revision as the end point at 12.4 years was 100% (95% confidence interval [CI], 94-100%) for the femoral component in both groups and 99% (95%CI, 93-100%) for the acetabular component. CONCLUSION The clinical and radiographic results of using an alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings were similar.
Collapse
|
41
|
Wang S, Zhang S, Zhao Y. A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up. J Orthop Surg Res 2013; 8:20. [PMID: 23835248 PMCID: PMC3720196 DOI: 10.1186/1749-799x-8-20] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2013] [Accepted: 07/03/2013] [Indexed: 11/10/2022] Open
Abstract
Study design This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. Background The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatable. We designed this retrospective study to compare polyethylene wear between alumina ceramic ball heads and cobalt-chrome ball heads. Methods Bilateral simultaneous primary total hip arthroplasty was performed in 22 patients between January 2002 and December 2002, with one side using metal-on-polyethylene bearing surface and the other side using alumina ceramic-on-polyethylene bearing surface. After 10 years of follow-up, the wear rate of polyethylene liner on both sides was measured using the Dorr method and compared. Results The annual wear rate of the polyethylene liner was 0.133 mm with a standard deviation of 0.045 in the metal-on-polyethylene group and 0.056 mm with a standard deviation of 0.032 in the ceramic-on-polyethylene group. The wear rate per year was significantly lower in the ceramic-on-polyethylene group (p < 0.001). Conclusions Although the implication is still controversial, our study showed that the use of ceramic head lowered the liner wear rate. Clinical relevance Ceramic is harder and more resistant to scratching than cobalt-chrome. By increasing polyethylene liner survivorship and decreasing potential osteolytic response and aseptic loosening, ceramic head is a better alternative than cobalt-chrome head.
Collapse
Affiliation(s)
- Shijun Wang
- Department of the Joint and Bone Surgery, Yantaishan Hospital, Yantai 264001, Shandong Province, China
| | | | | |
Collapse
|
42
|
Meftah M, Klingenstein GG, Yun RJ, Ranawat AS, Ranawat CS. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis. J Bone Joint Surg Am 2013; 95:1193-7. [PMID: 23824387 DOI: 10.2106/jbjs.l.00432] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Ceramic femoral heads produce less wear of the opposing polyethylene than do metal femoral heads in wear simulation studies. This is a matched-pair analysis of the wear of ceramic and metal femoral heads on conventional polyethylene in uncemented total hip replacements in young, active patients at a minimum of fifteen years of follow-up. METHODS From June 1989 to May 1992, thirty-one matched pairs of alumina ceramic or cobalt-chromium metal femoral heads were identified. Patients were matched on the basis of age, sex, body weight, diagnosis, and activity level. The mean age was 55 ± 9 years (range, twenty-three to sixty-five years) at the time of surgery. All procedures were performed with a posterolateral surgical approach by a single surgeon using press-fit Ranawat-Bernstein femoral stems, Harris-Galante-II acetabular cups, GUR 4150 conventional polyethylene (sterilized in argon), and 28-mm-diameter femoral heads. Wear measurements were performed by two independent observers using the computer-assisted Roman software. RESULTS The average duration of follow-up was 17 ± 1.7 years (range, fifteen to twenty years). The mean Hospital for Special Surgery hip scores (and standard deviation) in the ceramic and metal groups were 39 ± 4 and 40 ± 3 at the time of final follow-up. The University of California Los Angeles activity score at the time of the final follow-up was 6 ± 2 for both groups. The mean wear rates for the ceramic group and the metal group were 0.086 ± 0.05 mm/yr and 0.137 ± 0.05 mm/yr, respectively (p = 0.0015). There was one reoperation in the ceramic group because of distal femoral osteolysis. There were three failures in the metal group, requiring isolated liner exchange in two hips and revision of the acetabular component in one hip because of wear-induced osteolysis and/or loosening that caused symptoms. Five hips in the ceramic group and six hips in the metal group had radiographic evidence of acetabular or femoral osteolysis, but none were symptomatic. CONCLUSIONS Ceramic femoral heads produced significantly less wear on conventional polyethylene liners at the time of long-term follow-up than did metal heads in this matched-pair analysis of young and active patients with uncemented fixation.
Collapse
Affiliation(s)
- Morteza Meftah
- Weill Medical College of Cornell University, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA.
| | | | | | | | | |
Collapse
|
43
|
Comparison of conventional polyethylene wear and signs of cup failure in two similar total hip designs. Adv Orthop 2013; 2013:710621. [PMID: 23662210 PMCID: PMC3639702 DOI: 10.1155/2013/710621] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Revised: 03/06/2013] [Accepted: 03/06/2013] [Indexed: 11/17/2022] Open
Abstract
Multiple factors have been identified as contributing to polyethylene wear and debris generation of the acetabular lining. Polyethylene wear is the primary limiting factor in the functional behavior and consequent longevity of a total hip arthroplasty (THA). This retrospective study reviewed the clinical and radiographic data of 77 consecutive THAs comparing in vivo polyethylene wear of two similar acetabular cup liners. Minimum follow-up was 7 years (range 7-15). The incidence of measurable wear in a group of machined liners sterilized with ethylene oxide and composed of GUR 1050 stock resin was significantly higher (61%) than the compression-molded, GUR 1020, O2-free gamma irradiation sterilized group (24%) (P = 0.0004). Clinically, at a 9-year average followup, both groups had comparable HHS scores and incidence of thigh or groin pain, though the machined group had an increased incidence of osteolysis and annual linear wear rate.
Collapse
|
44
|
Oonishi H, Kyomoto M, Iwamoto M, Ueno M, Oonishi H. Radiographic and retrieval wear analyses of the first generation highly cross-linked polyethylene cup against a ceramic femoral head. J Biomed Mater Res B Appl Biomater 2013; 101:1594-601. [PMID: 23564746 DOI: 10.1002/jbm.b.32929] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Revised: 01/03/2013] [Accepted: 02/17/2013] [Indexed: 11/10/2022]
Abstract
In this study, the in vivo wear of highly cross-linked polyethylene (CLPE) cups against alumina ceramic femoral heads was evaluated by radiographic and retrieval analysis. The radiographic wear of six ethylene oxide gas-sterilized (i.e., non-cross-linked) conventional polyethylene (PE) cups with the mean follow-up of 20.9 years and 60 CLPE cups with the mean follow-up of 7.4 years was measured. The retrieved 16 PE cups with clinical use for mean 21.5 years and 10 CLPE cups with clinical use for mean 2.9 years was evaluated as a retrieval analysis. In the radiographic analysis, the linear wear of CLPE cups was significantly lower (99% reduction) compared to conventional polyethylene cups. The results of retrieval analyses for both cups were similar to those of radiographic analyses. Even when third-body wear occurred during clinical use, no surface damage was observed on the surface of ceramic femoral heads. The surface is not sensitive to third-body wear, and hence, the ceramic femoral head has a great advantage in terms of the wear of CLPE under third-body wear conditions. In conclusion, CLPE cups used with alumina ceramic femoral heads in total hip arthroplasty should have favorable wear resistance in several in vivo situations.
Collapse
Affiliation(s)
- Hiroyuki Oonishi
- H. Oonishi Memorial Joint Replacement Institute, Tominaga Hospital, Osaka, Japan
| | | | | | | | | |
Collapse
|
45
|
Helwig P, Konstantinidis L, Hirschmüller A, Bernstein A, Hauschild O, Südkamp NP, Ochs BG. Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients-laboratory and experimental analysis of suitability and clinical outcomes. INTERNATIONAL ORTHOPAEDICS 2012; 37:15-9. [PMID: 23223972 DOI: 10.1007/s00264-012-1735-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2012] [Accepted: 11/19/2012] [Indexed: 11/29/2022]
Abstract
PURPOSE One possibility in hip arthroplasty revisions is to combine a modular ceramic head with an adapter or sleeve in isolated acetabular cup replacement. This study consisted of an experimental part to analyse the reliability of taper damage predictions, and a clinical part to analyse the outcomes of modular ceramic head implantation in a case series of isolated cup replacements. METHODS Analysis of scratch size on 11 explanted hip stems were examined macroscopically and by stereomicroscopy to classify damage to the conical taper. The second part consisted of a prospective analysis of isolated cup revisions using a modular ceramic head, performed in two orthopedic centres. RESULTS Analysis of scratch size on the taper yielded inter-observer correlations of 0.545-0.909; comparison with stereomicroscopic data recordings yielded a moderate correlation, with values between 0.545 and 0.090. The clinical study included 47 isolated acetabular cup revisions involving modular ceramic heads. Ceramic head failure did not occur during the average clinical and radiological observation period of 26 months. Mean Harris Hip Score (HHS) at follow-up was 70 points. CONCLUSION From these results, it can be concluded that damage to the implanted stem taper cannot be reliably predicted intraoperatively. Nevertheless, the clinical outcomes did show that there were no problems with the ceramic heads over the short observation period. The application of modular ceramic heads in younger patients requiring isolated cup replacement requires proper risk-benefit analysis, but is possible and appears to be a safe procedure.
Collapse
Affiliation(s)
- Peter Helwig
- Department of Orthopaedics and Traumatology, Albert-Ludwigs-University Freiburg, Freiburg, Germany.
| | | | | | | | | | | | | |
Collapse
|
46
|
Rajaee SS, Trofa D, Matzkin E, Smith E. National trends in primary total hip arthroplasty in extremely young patients: a focus on bearing surface usage. J Arthroplasty 2012; 27:1870-8. [PMID: 22658430 DOI: 10.1016/j.arth.2012.04.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2011] [Accepted: 04/04/2012] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to present national trends in primary total hip arthroplasty (THA) and bearing surface usage for patients 30 years and younger. Using the Healthcare-Cost-and-Utilization-Project Nationwide Inpatient Sample for the years 2006 to 2009, 8919 primary THA discharges (4454 coded by bearing surface) were identified in patients 30 years and younger. The most commonly used bearing surface was metal-on-metal (MoM), representing 37.6% of cases, followed by ceramic-on-ceramic (CoC) (24.6%), metal-on-polyethylene (MoP) (22.1%) and ceramic-on-polyethylene (15.7%). From 2006 to 2009, the percentage of THAs that used hard-on-hard bearing surfaces decreased (MoM: 42.9%-29.4%; CoC: 34.0%-19.7%).This decrease in hard-on-hard bearing surface usage presents a challenge for surgeons treating young patients to find other acceptable durable bearings that do not have the potential problems associated with MoM or CoC.
Collapse
Affiliation(s)
- Sean S Rajaee
- Department of Orthopedics, Tufts Medical Center/Tufts University School of Medicine, Boston, MA 02111, USA
| | | | | | | |
Collapse
|
47
|
McCoy TH, Goldman V, Fragomen AT, Rozbruch SR. Circular external fixator-assisted ankle arthrodesis following failed total ankle arthroplasty. Foot Ankle Int 2012; 33:947-55. [PMID: 23131440 DOI: 10.3113/fai.2012.0947] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Failed total ankle arthroplasty (TAA) often results in significant bone loss and requires salvage arthrodesis. This study quantified the bone loss following failed TAA and reports the outcome of seven arthrodesis reconstructions using the Ilizarov method. METHODS A retrospective review of ankle fusions was performed for failed TAA to collect the mode of implant failure, presenting limb length discrepancy (LLD), total bone defect, postarthrodesis LLD, and treatment type (shoe lift versus distraction osteogenesis) and amount (shoe lift or lengthening). RESULTS Four mechanical failures and three infections were found. Four of seven cases had prior revision TAAs. Four of seven patients were treated with tibiotalar arthrodesis; three of the seven patients required talar resection and tibiocalcaneal arthrodesis. The mean presenting LLD was 2.2 (range, 1.2 to 3.5) cm. The mean time in frame was 197 (range, 146 to 229) days. With a mean postexplantation total bone defect of 5.1 (range, 3.7 to 8.5) cm, four of seven patients elected tibial lengthening following fusion [mean lengthening 4.6 (range, 2.5 to 8.0) cm; external fixation index (EFI) 42.6 (range, 16.5 to 55.6) days/cm)]. Three of seven patients were treated with a shoe lift [mean lift height 2.9 (range 2.5 to 3.2) cm]. There was no failure of fixation, refracture, or infection. All patients had a stable plantigrade foot and walked with minimal limp. Association for the Study and Application of the Method of Ilizarov (ASAMI) functional scores were six good and one fair. ASAMI bone scores were four excellent and three good. CONCLUSIONS Ankle arthrodesis following failed TAA results in large LLDs secondary to bone loss during implant failure and subsequent explantation. External fixation can produce an excellent fusion rate in complex, possibly infected, failed TAAs. Limb length equalization (by either distraction osteogenesis or shoe lift) provides a means of obtaining good functional outcomes following failed TAA.
Collapse
|
48
|
|
49
|
IKEDA J, IWAMOTO M, YARIMITSU S, MURAKAMI T. Differences in Kinetics of Phase Transformation of 3Y-TZP Ceramics between Aging Test under Hydrothermal Environment and Hip Simulator Wear Test. ACTA ACUST UNITED AC 2012. [DOI: 10.1299/jbse.7.199] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
50
|
Ihle M, Mai S, Siebert W. Ceramic Versus Metal Femoral Heads in Combination With Polyethylene Cups. ACTA ACUST UNITED AC 2011. [DOI: 10.1053/j.sart.2011.09.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|