1
|
Roche O, Schmitz A, Lefevre M, Sirveaux F, Bonnomet F. New comprehensive score for predicting difficulties in revision total hip arthroplasty. Orthop Traumatol Surg Res 2025; 111:103983. [PMID: 39218300 DOI: 10.1016/j.otsr.2024.103983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 04/24/2024] [Accepted: 05/07/2024] [Indexed: 09/04/2024]
Abstract
BACKGROUND Revision total hip arthroplasty (THA) can be complex, and assessing possible difficulties is important to predict the operative time. No simple score for predicting difficulties has been assessed prospectively. We therefore developed an original score for the pre-operative evaluation of extraction and reconstruction difficulties. The objectives of this prospective study were to (1) assess correlations between score values and operative time, (2) determine whether the score predicted the need for revision implants and/or filling material, (3) determine whether the score predicted intra-operative and post-operative complications, and (4) evaluate the inter-observer and intra-observer reproducibility of the score. HYPOTHESIS The score is reproducible and correlates well with the operative time, thereby allowing prediction of this parameter before surgery. MATERIAL AND METHODS A prospective study of 103 revision THA procedures performed between March 2018 and August 2023 was conducted. The primary outcome was operative time and the secondary outcomes were use of a revision implant, use of filling material, and intra-operative and post-operative complications. The score was determined by four observers to allow evaluation of inter-observer agreement. Intra-observer agreement was assessed by having one of the observers determine the score a second time after inclusion of the last patient. The score has a maximum value of 20 and allows classification of the procedure as very difficult, difficult, and moderately difficult. RESULTS Mean operative time correlated with the score value: 136.0 ± 33.9 min in the very difficult group, 102.0 ± 34.8 min in the difficult group, and 75.4 ± 65.5 min in the moderately difficult group (p = 0.0002). The score predicted the use of a reinforcement ring (40 procedures: 12/17 [70%], 11/25 [44%], and 17/61 [28%] in the very difficult, difficult, and moderately difficult groups, respectively; p = 0.01) and of a long stem (20 procedures: 8/17 [47%], 7/25 [28%], and 5/61 [8%] patients in the very difficult, difficult, and moderately difficult groups, respectively; p < 0.001). The score did not predict the use of filling material (42 procedures: 10/17 [59%], 9/25 [36%], and 23/61 [37%] in the very difficult, difficult, and moderately difficult groups, respectively; p = 0.250). The score predicted both intra-operative complications (5/17 [29%], 4/25 [16%], and 4/61 [6%] procedures in the very difficult, difficult, and moderately difficult groups, respectively; p = 0.028) and post-operative complications (4/17 [23%], 0/25 [0%], and 6/61 [9%] in the very difficult, difficult, and moderately difficult groups, respectively; p = 0.15). Inter-observer agreement was strong according to Landis-Koch criteria, with kappa values ranging from 0.70 to 0.79 [0.57-0.90]. The kappa value for intra-observer agreement was 0.74 [0.63-0.85]. DISCUSSION This score predicts surgical difficulties by adding criteria to bone destruction, in contrast to widely used classifications for revision THA. Moreover, the score is reproducible and predicts the operative time, thus potentially playing an important role during pre-operative planning. LEVEL OF EVIDENCE IV; prospective observational non-comparative study.
Collapse
Affiliation(s)
- Olivier Roche
- Service de Chirurgie Orthopédique du Centre Chirurgical Émile Galle (CCEG), CHU de Nancy, France.
| | - Arthur Schmitz
- Service de Chirurgie Orthopédique du Centre Chirurgical Émile Galle (CCEG), CHU de Nancy, France
| | - Maxime Lefevre
- Service de Chirurgie Orthopédique du Centre Chirurgical Émile Galle (CCEG), CHU de Nancy, France
| | - François Sirveaux
- Service de Chirurgie Orthopédique du Centre Chirurgical Émile Galle (CCEG), CHU de Nancy, France
| | - François Bonnomet
- Service de Chirurgie Orthopédique du CHU de Strasbourg, Hôpital de Hautepierre, France
| |
Collapse
|
2
|
Chen JS, Paksima N, Rocks MC, Lin CC, Catalano LW. Osteolysis Following the Use of Polyetheretherketone Suture Anchors in Hand and Wrist Surgery: A Preliminary Study. J Hand Surg Am 2025; 50:235.e1-235.e6. [PMID: 37542497 DOI: 10.1016/j.jhsa.2023.05.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 05/14/2023] [Accepted: 05/31/2023] [Indexed: 08/07/2023]
Abstract
PURPOSE The objective of this study was to investigate and describe the presence of osteolysis after implantation of polyetheretherketone (PEEK) suture anchors in the hand and wrist. METHODS Patients who underwent hand or wrist surgery using PEEK suture anchor(s) at a large academic institution from January 2019 to January 2021 were identified. Patients without accessible intraoperative fluoroscopic imaging were excluded. Patient demographics, type of procedure, and suture anchor material were recorded. The suture anchor tunnel size was measured on sequential radiographs and recorded as percentage change. Descriptive statistics were used to summarize findings. RESULTS A total of 26 PEEK suture anchors in 14 patients were included, with an average follow-up of 12.0 months (range, 1.5-24.1 months). Twenty-seven percent of the anchors (7/26) demonstrated osteolysis at final follow-up, as defined by enlargement of tunnel size by >30%. In all anchors, the tunnel size increased by 19.1% on average (range, -7.7% to 56.1%) by final follow-up. CONCLUSIONS Polyetheretherketone suture anchors may be associated with the development of osteolysis in hand and wrist surgery. The clinical implications of osteolysis in the smaller bones of the hand and wrist remain unclear. TYPE OF STUDY/LEVEL OF EVIDENCE Prognostic IV.
Collapse
Affiliation(s)
- Jeffrey S Chen
- Department of Orthopedic Surgery, New York University Langone Orthopedic Hospital, NYU Langone Health, New York, NY.
| | - Nader Paksima
- Department of Orthopedic Surgery, New York University Langone Orthopedic Hospital, NYU Langone Health, New York, NY
| | - Madeline C Rocks
- Department of Orthopedic Surgery, New York University Langone Orthopedic Hospital, NYU Langone Health, New York, NY
| | - Charles C Lin
- Department of Orthopedic Surgery, New York University Langone Orthopedic Hospital, NYU Langone Health, New York, NY
| | - Louis W Catalano
- Department of Orthopedic Surgery, New York University Langone Orthopedic Hospital, NYU Langone Health, New York, NY; Department of Orthopedic Surgery, University of Colorado Anschutz Medical Campus, Aurora, CO
| |
Collapse
|
3
|
Fritz J, Rashidi A, de Cesar Netto C. Magnetic Resonance Imaging of Total Ankle Arthroplasty: State-of-The-Art Assessment of Implant-Related Pain and Dysfunction. Clin Podiatr Med Surg 2024; 41:619-647. [PMID: 39237176 DOI: 10.1016/j.cpm.2024.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Total ankle arthroplasty (TAA) is an effective alternative for treating patients with end-stage ankle degeneration, improving mobility, and providing pain relief. Implant survivorship is constantly improving; however, complications occur. Many causes of pain and dysfunction after total ankle arthroplasty can be diagnosed accurately with clinical examination, laboratory, radiography, and computer tomography. However, when there are no or inconclusive imaging findings, magnetic resonance imaging (MRI) is highly accurate in identifying and characterizing bone resorption, osteolysis, infection, osseous stress reactions, nondisplaced fractures, polyethylene damage, nerve injuries and neuropathies, as well as tendon and ligament tears. Multiple vendors offer effective, clinically available MRI techniques for metal artifact reduction MRI of total ankle arthroplasty. This article reviews the MRI appearances of common TAA implant systems, clinically available techniques and protocols for metal artifact reduction MRI of TAA implants, and the MRI appearances of a broad spectrum of TAA-related complications.
Collapse
Affiliation(s)
- Jan Fritz
- Department of Orthopedic Surgery, Division of Foot and Ankle Surgery, Duke University, Durham, NC, USA.
| | - Ali Rashidi
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Floor, Rm 313, New York, NY 10016, USA
| | - Cesar de Cesar Netto
- Department of Radiology, Molecular Imaging Program at StanDepartment of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
4
|
Ferrao PNF, Saragas NP, Naude JJ. Outcomes of Total Ankle Arthroplasty After Periprosthetic Cyst Curettage and Bone Grafting. Foot Ankle Clin 2024; 29:123-143. [PMID: 38309797 DOI: 10.1016/j.fcl.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2024]
Abstract
Total ankle arthroplasty (TAA) has become a popular management option for ankle arthritis. Periprosthetic osteolysis is one of the most common causes for reoperation in TAA. A CT scan should be done in all suspected osteolysis cases to confirm location, quantify size and aid in surgical planning. These patients are often asymptomatic with limited evidence regarding appropriate management. Smaller lesions should be monitored for progression in size. Periprosthetic cysts measuring 10-15mm in all three axes should be considered for debridment and curettage with autogenous bone grafting. The authors believe that bone grafting of large asymptomatic periprosthetic cysts could prevent implant failure.
Collapse
Affiliation(s)
- Paulo N F Ferrao
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Department of Orthopaedic Surgery, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa.
| | - Nikiforos P Saragas
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Department of Orthopaedic Surgery, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa
| | - Jaco J Naude
- The Orthopaedic Foot & Ankle Unit, Netcare Linksfield Hospital, 303 Linksfield Medical Centre, 24 12th Avenue, Linksfield West, 2192, South Africa; Life Wilgers Hospital, Denneboom road, Wilgers ext 14, Pretoria, 0040, South Africa
| |
Collapse
|
5
|
Fritz J, Rashidi A, de Cesar Netto C. Magnetic Resonance Imaging of Total Ankle Arthroplasty: State-of-The-Art Assessment of Implant-Related Pain and Dysfunction. Foot Ankle Clin 2023; 28:463-492. [PMID: 37536814 DOI: 10.1016/j.fcl.2023.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Total ankle arthroplasty (TAA) is an effective alternative for treating patients with end-stage ankle degeneration, improving mobility, and providing pain relief. Implant survivorship is constantly improving; however, complications occur. Many causes of pain and dysfunction after total ankle arthroplasty can be diagnosed accurately with clinical examination, laboratory, radiography, and computer tomography. However, when there are no or inconclusive imaging findings, magnetic resonance imaging (MRI) is highly accurate in identifying and characterizing bone resorption, osteolysis, infection, osseous stress reactions, nondisplaced fractures, polyethylene damage, nerve injuries and neuropathies, as well as tendon and ligament tears. Multiple vendors offer effective, clinically available MRI techniques for metal artifact reduction MRI of total ankle arthroplasty. This article reviews the MRI appearances of common TAA implant systems, clinically available techniques and protocols for metal artifact reduction MRI of TAA implants, and the MRI appearances of a broad spectrum of TAA-related complications.
Collapse
Affiliation(s)
- Jan Fritz
- Department of Orthopedic Surgery, Division of Foot and Ankle Surgery, Duke University, Durham, NC, USA.
| | - Ali Rashidi
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Floor, Rm 313, New York, NY 10016, USA
| | - Cesar de Cesar Netto
- Department of Radiology, Molecular Imaging Program at StanDepartment of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
6
|
Yamamoto N, Takada R, Jinno T, Miyatake K, Watanabe N, Koga H, Yoshii T, Yagishita K, Okawa A. Wear rate and osteolysis in two types of second-generation annealed highly cross-linked polyethylene in total hip arthroplasty: A retrospective comparative study with a minimum of five years. Orthop Traumatol Surg Res 2023; 109:103147. [PMID: 34793945 DOI: 10.1016/j.otsr.2021.103147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/19/2021] [Accepted: 02/25/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND As no previous study has directly compared the linear wear rate in two types of second-generation annealed highly cross-linked polyethylene, we performed a retrospective study with a minimum of 5-year follow-up to assess primary arthroplasties in the (1) wear rates and (2) incidence of osteolysis of the two types of HXLPE. HYPOTHESIS There was no significant difference in the linear wear rate and the incidence of osteolysis between the two types of second-generation annealed highly cross-linked polyethylene. PATIENTS AND METHODS In this single-center study, we reviewed 257 cases of primary cementless total hip arthroplasties between 2011 and 2015, which were performed with 32mm delta ceramic on second-generation annealed highly cross-linked polyethylene (X3 and E1 were used in 105 and 103 cases, respectively.). The mean wear rate was evaluated using a computer-assisted method, and the incidence of osteolysis was evaluated based on the appearance of a localized area with loss of trabecular bone or cortical erosion adjacent to the implants during the latest follow-up. RESULTS In total, we evaluated 208 cases, followed postoperatively for over 5 years (mean, 6.1 years, range: 5.0-8.0). There were no significant differences between the two groups with respect to age (list in order of Group X, Group E, p value) (61.2±12.3, 62.7±12.1, p=0.36), sex (ratio of male: 17.1%, 14.6%, p=0.61), body mass index (22.9±3.7, 22.8±4.0, p=0.91), pre- (49.9±14.8, 48.5±13.8, p=0.49) and post-operative (91.3±9.1, 92.7±7.0, p=0.23) Japanese Orthopaedic Association Hip Score, cup size (50.8±3.0, 50.9±2.2, p=0.70), cup inclination (38.7±4.8, 37.6±4.8, p=0.10), and cup anteversion (18.7±6.9, 18.5±7.6, p=0.80). The mean linear wear rates of the X3 and E1 groups were 0.057±0.039 (range: 0-0.16) and 0.054±0.037mm/year (range: 0-0.15), respectively (p=0.61). No osteolysis was found on the final plain radiographs in both groups. DISCUSSION This study revealed that both types of highly cross-linked polyethylene have excellent linear wear rates and were equally safe to use. However, the difference between the two materials in terms of the long-term wear rate should be further validated. LEVEL OF EVIDENCE III; retrospective case control study.
Collapse
Affiliation(s)
- Naoki Yamamoto
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Ryohei Takada
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan.
| | - Tetsuya Jinno
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Kazumasa Miyatake
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Naoto Watanabe
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Hideyuki Koga
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Toshitaka Yoshii
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Kazuyoshi Yagishita
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| | - Atsushi Okawa
- Department of Orthopaedic Surgery Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, 113-8519 Tokyo, Japan
| |
Collapse
|
7
|
Tsukada S, Wakui M, Kizaki K, Iseki T, Miyao M, Tasaki A. Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up. Arch Orthop Trauma Surg 2022; 142:1689-1695. [PMID: 34269893 DOI: 10.1007/s00402-021-04055-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 07/02/2021] [Indexed: 01/15/2023]
Abstract
INTRODUCTION The effectiveness of modern ceramic bearings has been well established in reducing the osteolysis associated with wear of the bearing surfaces in total hip arthroplasty (THA). However, there are limited mid- to long-term follow-up data for complications associated with ceramic bearings. MATERIALS AND METHODS This case series analyzed 124 consecutive primary uncemented THAs in 108 patients with a mean age of 61 years using alumina ceramic-on-alumina ceramic bearing couples. Seventy THAs (56%) were evaluated at a minimum 14 years of follow-up; the mean follow-up period was 16 ± 1 years (14-20 years). Kaplan-Meier survivorship was determined with revision surgery for any reason as the end point. Complications were recorded focusing on osteolysis, ceramic fracture, and abnormal sounds until the final follow-up. Clinical data were scored according to the Merle d'Aubigne and Postel hip score at 14 years after THA. RESULTS The survivorship was 93.5% (95% CI 86.7-97.0%) at 14-years postoperatively. Five patients (4.0%) underwent revision surgery due to instability or infection before 1-year postoperatively. Two patients (1.6%) underwent revision surgery due to ceramic liner fracture at 9- and 12-years postoperatively, respectively. There was no radiographic evidence of osteolysis. A total of 27 complications occurred: dislocations (n = 7/124), squeaking sounds (n = 3/124), clicking sounds (n = 6/124), ceramic liner fractures (n = 2/124), periprosthetic fractures (n = 4/124), deep infections (n = 2/124), transient sciatic nerve palsy (n = 2/124), and femoral stem breakage (n = 1/124). The Merle d'Aubigne and Postel hip score was 16.8 ± 1.4 points. CONCLUSIONS The survivorship analysis demonstrates the uncemented THA using alumina ceramic bearings may provide favorable clinical outcome and can offer minimal wear at a minimum 14-year follow-up. Revision surgery was mostly required due to instability and infection in the short-term, and implant breakage in the mid- to long-term.
Collapse
Affiliation(s)
- Sachiyuki Tsukada
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo City, Niigata, 950-1151, Japan. .,Department of Orthopaedic Surgery, Hokusuikai Kinen Hospital, 3-2-1 Higashihara, Mito, Ibaraki, 310-0035, Japan.
| | - Motohiro Wakui
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo City, Niigata, 950-1151, Japan
| | - Kazuha Kizaki
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo City, Niigata, 950-1151, Japan
| | - Takuya Iseki
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo City, Niigata, 950-1151, Japan
| | - Masunao Miyao
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo City, Niigata, 950-1151, Japan
| | - Atsushi Tasaki
- Department of Orthopaedic Surgery, St. Luke's International Hospital, 9-1 Akashi Cho, Chuo City, Tokyo, 104-8560, Japan
| |
Collapse
|
8
|
Holzapfel BM, Corten K, Goldberg T, Rudert M, Nogler M, Moskal J, Thaler M. Acetabular defect management and revision arthroplasty via the direct anterior approach. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2022; 34:203-217. [PMID: 35680676 DOI: 10.1007/s00064-022-00767-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 03/06/2021] [Accepted: 03/13/2021] [Indexed: 06/15/2023]
Abstract
OBJECTIVE Acetabular revision arthroplasty and osseous defect management through the direct anterior approach (DAA) with or without proximal extension. INDICATIONS Aseptic or septic component loosening, periacetabular osseous defects, pelvic discontinuity, intrapelvic cup protrusion, anterior pseudotumors, iliopsoas tendonitis, polyethylene wear or iliopsoas abscess. CONTRAINDICATIONS Clinically relevant gluteal tendon lesions, active infection, morbid obesity, large abdominal pannus, ASA (American Society of Anesthesiologists) score > III, inguinal skin infection. SURGICAL TECHNIQUE Electrocautery dissection is recommended to dissect the Hueter interval and to debulk pericapsular scar tissue. At all times during capsular debulking, it should be made sure not to damage the iliopsoas tendon or the neurovascular bundle. A stepwise releasing sequence can facilitate dislocation of the prosthesis. Most cases can be revised via the standard DAA but certain circumstances require an intra- or extrapelvic extension. Access to the anterior gluteal surface of the ilium can be provided using a "tensor snip". More posterior access is provided by the extensile extrapelvic approach described by Smith-Petersen. The intrapelvic Levine extension offers access to the entire visceral surface of the ilium and large parts of the anterior column. POSTOPERATIVE MANAGEMENT Patient revised via the intra- or extrapelvic extension and patients suffering from extensive soft tissue or osseous defects should undergo postoperative weight-bearing restrictions with 20 kg for 6 weeks. RESULTS Based on our studies, there is no limitation on the type of acetabular implant that can be used in DAA revision arthroplasty. Moreover, virtually all types of periacetabular osseous defects can be managed through the approach and its extensions. Acetabular revision arthroplasty via the DAA and its extensions is safe and can result in good midterm results.
Collapse
Affiliation(s)
- Boris Michael Holzapfel
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Kristoff Corten
- Hip Unit, Orthopedic Department, Ziekenhuis Ooost-Limburg Genk, Schiepse Bos 6, 3600, Genk, Belgium
| | - Tyler Goldberg
- 4700 Seton Center Parkway, Texas Orthopedics, LLC, 78759, Austin, TX, USA
| | - Maximilian Rudert
- Department of Orthopedic Surgery, University of Wuerzburg, Koenig-Ludwig-Haus, Brettreichstr. 11, 97074, Wuerzburg, Germany
| | - Michael Nogler
- Department of Experimental Orthopedics, Department of Orthopedics and Traumatology, Medical University Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria
| | - Joseph Moskal
- Department of Orthopedic Surgery, Virginia Tech Carilion School of Medicine, Institute for Orthopedics and Neuroscience, 2331 Franklin Rd, 24014, SW, Roanoke, VA, USA
| | - Martin Thaler
- Arthroplasty Center, Helios Klinikum Munich West, Steinerweg 5, 81241, Munich, Germany
- Center of Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University of Greifswald, Greifswald, Germany
| |
Collapse
|
9
|
Zhang J, Hu Y, Ying H, Mao Y, Zhu Z, Li H. Reliability and validity test of a novel three-dimensional acetabular bone defect classification system aided with additive manufacturing. BMC Musculoskelet Disord 2022; 23:432. [PMID: 35534887 PMCID: PMC9082860 DOI: 10.1186/s12891-022-05365-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 04/25/2022] [Indexed: 01/18/2023] Open
Abstract
Background Accurate assessment of acetabular defects and designing precise and feasible surgical plans are essential for positive outcomes of hip revision arthroplasty. Additive manufacturing (AM) is a novel technique to print physical object models. We propose a three-dimensional acetabular bone defect classification system aided with AM model, and further assess its reliability and validity under blinded conditions. Methods We reviewed 104 consecutive patients who underwent hip revision arthroplasty at our department between January 2014 and December 2019, of whom 45 had AM models and were included in the reliability and validity tests. Three orthopedic surgeons retrospectively evaluated the bone defects of these 45 patients with our proposed classification, made surgical plans, and repeated the process after 2 weeks. The reliability and validity of the classification results and corresponding surgical plans were assessed using the intra-class correlation coefficient or kappa correlation coefficient. Results The reliability and validity of the classification results were excellent. The mean initial intra-class correlation coefficient for inter-observer reliability was 0.947, which increased to 0.972 when tested a second time. The intra-observer reliability ranged from 0.958 to 0.980. Validity of the classification results also showed a high kappa correlation coefficient of 0.951–0.967. When considering corresponding surgical plans, the reliability and validity were also excellent, with intra-class correlation coefficients and kappa correlation coefficients measuring all over 0.9. Conclusions This three-dimensional acetabular defect classification has excellent reliability and validity. Using this classification system and AM models, accurate assessment of bone defect and reliable surgical plans could be achieved. This classification aided with AM is a promising tool for surgeons for preoperative evaluation.
Collapse
Affiliation(s)
- Jingwei Zhang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Yi Hu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Hua Ying
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Yuanqing Mao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China
| | - Zhenan Zhu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China.
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639# Zhizaoju Road, Shanghai, 200011, People's Republic of China.
| |
Collapse
|
10
|
Naude JJ, Saragas NP, Ferrao PNF. CT Scan Assessment and Functional Outcome of Periprosthetic Bone Grafting After Total Ankle Arthroplasty at Medium-term Follow-up. Foot Ankle Int 2022; 43:609-619. [PMID: 35073771 DOI: 10.1177/10711007211064612] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Periprosthetic cysts can occur in up to 95% of total ankle arthroplasties (TAA) and have been correlated with implant failure. The aim of this study was to determine the clinical and radiologic outcomes, using computed tomographic (CT) scan, after periprosthetic cyst bone grafting and assess for the minimum cyst size that should be grafted. METHODS A retrospective review was performed of all TAA procedures performed between 2007 and 2014 (n=93). A CT scan was done to assess cyst size and operative planning. Eight patients with 9 periprosthetic cysts larger than 1.75 cm3 were grafted and specimens sent for histology. The mean time to bone grafting was 7.3 (3.8-9.5) years. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society ankle score, visual analog scale, and Self-reported Foot and Ankle Score. A CT scan was performed at follow-up to assess graft incorporation and cyst size progression. The mean time to CT scan post grafting was 3.0 (0.7-4.7) years. RESULTS There was no implant malalignment identified and no differences in the pre- and postoperative functional scores. Preoperatively cysts had a mean volume of 8.16 (2.04-14.03) cm3. The mean percentage incorporation was 89% (69%-100%). Eight of the grafted cysts were considered successful on CT, with the ninth having 69% incorporation. Five cysts were not grafted, as they were below 1.75 cm3, and remained the same size or had minimal enlargement. CONCLUSION The satisfactory results in this small cohort suggests that prophylactic bone grafting may extend implant survival. We recommend that periprosthetic cysts greater than 1.75 cm3 be prophylactically bone grafted, and that cysts smaller than 1.75 cm3 be monitored for progression in size. LEVEL OF EVIDENCE Level IV, Case Series.
Collapse
Affiliation(s)
- Jaco J Naude
- The Orthopaedic Foot and Ankle Unit, Netcare Linksfield Hospital, Johannesburg, Gauteng, South Africa.,Department of Orthopaedic Surgery, University of the Witwatersrand, Johannesburg, South Africa
| | - Nikiforos P Saragas
- The Orthopaedic Foot and Ankle Unit, Netcare Linksfield Hospital, Johannesburg, Gauteng, South Africa.,Department of Orthopaedic Surgery, University of the Witwatersrand, Johannesburg, South Africa
| | - Paulo N F Ferrao
- The Orthopaedic Foot and Ankle Unit, Netcare Linksfield Hospital, Johannesburg, Gauteng, South Africa.,Department of Orthopaedic Surgery, University of the Witwatersrand, Johannesburg, South Africa
| |
Collapse
|
11
|
Mehta N, Serino J, Hur ES, Smith S, Hamid KS, Lee S, Bohl DD. Pathogenesis, Evaluation, and Management of Osteolysis Following Total Ankle Arthroplasty. Foot Ankle Int 2021; 42:230-242. [PMID: 33345610 DOI: 10.1177/1071100720978426] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Periprosthetic osteolysis is a common occurrence after total ankle arthroplasty (TAA) and poses many challenges for the foot and ankle surgeon. Osteolysis may be asymptomatic and remain benign, or it may lead to component instability and require revision or arthrodesis. In this article, we present a current and comprehensive review of osteolysis in TAA with illustrative cases. We examine the basic science principles behind the etiology of osteolysis, discuss the workup of a patient with suspected osteolysis, and present a review of the evidence of various management strategies, including grafting of cysts, revision TAA, and arthrodesis.Level of Evidence: Level V, expert opinion.
Collapse
Affiliation(s)
- Nabil Mehta
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Joseph Serino
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Edward S Hur
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Shelby Smith
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Kamran S Hamid
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Simon Lee
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Daniel D Bohl
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
12
|
Aprato A, Olivero M, Di Benedetto P, Massè A. Decision/therapeutic algorithm for acetabular revisions. ACTA BIO-MEDICA : ATENEI PARMENSIS 2020; 91:e2020025. [PMID: 33559630 PMCID: PMC7944694 DOI: 10.23750/abm.v91i14-s.10999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 12/03/2020] [Indexed: 11/23/2022]
Abstract
Background and aim: Paprosky’s classification is currently the most used classification for periacetabular bone defects but its validity and reliability are widely discussed in literature. Aim of this study was to introduce a new CT-based Acetabular Revision Algorithm (CT-ARA) and to evaluate its validity. The CT-ARA is based on the integrity of five anatomical structures that support the acetabulum. Classification’s groups are defined by the deficiency of one or more of these structures, treatment is based on those groups. Methods: In 105 patients the validity of the CT-ARA was retrospectively evaluated using preoperative X-rays, CT-scan and surgery reports. The surgical indications suggested by Paprosky’s algorithm and by CT-ARA were compared with the final surgical technique. Patients were divided into two groups according to time of surgery. Results: We reported concordance of indications in 56,2% of cases with the Paprosky’s algorithm and in 63,8% of cases with the CT-ARA. Analysing only the most recent surgeries (group 2), we reported even higher difference of concordance (67,3% Paprosky’s algorithm and 83,7% CT-ARA). The concordance of the CT-ARA among Group 1 and Group 2 resulted significantly different. Conclusions: the CT-ARA may be a useful tool for the preoperative decision-making process and showed more correlation with performed surgery compared to the Paprosky’s algorithm.
Collapse
|
13
|
Alamanda VK, Demartino I, Potter HG, Koff MF, Lin B, Muskat A, Westrich GH. Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell. Arthroplast Today 2020; 6:694-698. [PMID: 32923552 PMCID: PMC7475047 DOI: 10.1016/j.artd.2020.07.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/29/2020] [Accepted: 07/11/2020] [Indexed: 01/01/2023] Open
Abstract
Background The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation in 3 dimensions may allow a better understanding of the implant design and bony integration. We hypothesized that a new 3-dimensionally printed cementless highly porous acetabular component (Stryker Trident II TritaniumTM) would show better fixation than an earlier cup from the same manufacturer as assessed by the noninvasive technique of multispectral MRI. Methods Multiacquisition variable-resonance image combination selective metal suppression MRI was performed in 19 patients implanted with a new 3-dimensionally printed cup and 20 patients who had received a previous-generation cup from the same manufacturer at 1-year follow-up. Each cup was graded globally as well as by 9 specific zones. Integration grades were performed for each zone: 0, full bone integration; 1, fibrous membrane present; 2, osteolysis; and 3, fluid present. A mixed-effects logistic regression model was used to compare fixation between the 2 groups. Results All cups in both cohorts showed greater than 90% estimated global bony integration (3-dimensionally printed cups, 99.4%; regular cups 91.6%) with no osteolysis or fluid observed in any cup. The 3-dimensionally printed cup had 1 of 171 zones (0.6%) graded as fibrous membrane present, while the 2-dimensional group had 15 of 180 zones (8.3%) graded as fibrous. Of note, screw hole regions were omitted but may be read as fibrous membrane areas. Conclusion Using multiacquisition variable-resonance image combination selective MRI, our analysis showed greater osteointegration and less fibrous membrane formation in the 3-dimensionally printed cups than the control group at 1-year follow-up.
Collapse
Affiliation(s)
- Vignesh K Alamanda
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Ivan Demartino
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Matthew F Koff
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | - Bin Lin
- Department of Biostatistics, Hospital for Special Surgery, New York, NY, USA
| | - Ahava Muskat
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Geoffrey H Westrich
- Department of Orthopedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
14
|
Langlois J, Hamadouche M. Recent update on crosslinked polyethylene in total hip arthroplasty. SICOT J 2020; 6:13. [PMID: 32412408 PMCID: PMC7227368 DOI: 10.1051/sicotj/2020013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 02/02/2023] Open
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|
15
|
Computed Tomographic Osteolytic Analysis of a First-Generation Remelted Highly Cross-Linked Polyethylene in Total Hip Arthroplasty-At a Minimum of 15-Year Follow-Up. J Arthroplasty 2020; 35:1417-1423. [PMID: 31948813 DOI: 10.1016/j.arth.2019.12.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/25/2019] [Accepted: 12/09/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Low polyethylene wear rate and low incidence of osteolysis have been reported after total hip arthroplasty (THA) using first-generation remelted highly cross-linked polyethylene (HXLPE). However, osteolysis has not been evaluated in long-term studies of these patients (15 years or more). The present study assessed computed tomography (CT) images to determine the incidence of osteolysis associated with HXLPE in THA during at least 15 years of follow-up. METHODS We evaluated 105 primary THAs in 84 patients (77 women and 7 men). Mean follow-up was 15.9 years (range, 15-18 years). All THAs used a Longevity HXLPE liner and a 26-mm zirconia femoral head. Areas of osteolysis were identified from CT images using 3D and multiplanar reconstruction views. RESULTS CT 3D multiplanar reconstruction images at 15-year follow-up showed no obvious osteolysis in the acetabulum or femur of any patient. No patients developed cup loosening or liner breakage. CONCLUSION Our study indicates that first-generation remelted HXLPE liners do not increase the risk of osteolysis during 15-year follow-up and suggests that the wear particles from first-generation remelted HXLPE are less biologically active than those generated by conventional polyethylene devices.
Collapse
|
16
|
Wirtz DC, Jaenisch M, Osterhaus TA, Gathen M, Wimmer M, Randau TM, Schildberg FA, Rössler PP. Acetabular defects in revision hip arthroplasty: a therapy-oriented classification. Arch Orthop Trauma Surg 2020; 140:815-825. [PMID: 32100108 PMCID: PMC7244606 DOI: 10.1007/s00402-020-03379-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Indexed: 12/13/2022]
Abstract
INTRODUCTION The treatment of severe acetabular bone loss remains a difficult challenge. No classification system is available that combines intuitive use, structured design and offers a therapeutic recommendation according to the current literature and modern state of the art treatment options. The goal of this study is to introduce an intuitive, reproducible and reliable guideline for the evaluation and treatment of acetabular defects. METHODS The proposed Acetabular Defect Classification (ADC) is based on the integrity of the acetabular rim and supporting structures. It consists of 4 main types of defects ascending in severity and subdivisions narrowing down-defect location. Type 1 presents an intact acetabular rim, type 2 includes a noncontained defect of the acetabular rim ≤ 10 mm, in type 3 the rim defect exceeds 10 mm and type 4 includes different kinds of pelvic discontinuity. A collective of 207 preoperative radiographs were graded according to ADC and correlated with intraoperative findings. Additionally, a randomized sample of 80 patients was graded according to ADC by 5 observers to account for inter- and intra-rater reliability. RESULTS We evaluated the agreement of preoperative, radiographic grading and intraoperative findings presenting with a k value of 0.74. Interobserver agreement presented with a k value of 0.62 and intraobserver at a k value of 0.78. CONCLUSION The ADC offers an intuitive, reliable and reproducible classification system. It guides the surgeon pre- and intraoperatively through a complex field of practice.
Collapse
Affiliation(s)
- Dieter Christian Wirtz
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Max Jaenisch
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Thiemo Antonius Osterhaus
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Martin Gathen
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Matthias Wimmer
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Thomas Martin Randau
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Frank Alexander Schildberg
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| | - Philip Peter Rössler
- Department of Orthopaedics and Traumatology, University Hospital Bonn, Germany, Sigmund-Freud-Straße 25, 53127 Bonn, Germany
| |
Collapse
|
17
|
Tikhilov RM, Shubnyakov II, Denisov AO. Classifications of Acetabular Defects: Do They Provide an Objective Evidence for Complexity of Revision Hip Joint Arthroplasty? (Critical Literature Review and Own Cases). TRAUMATOLOGY AND ORTHOPEDICS OF RUSSIA 2019. [DOI: 10.21823/2311-2905-2019-25-1-122-141] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- R. M. Tikhilov
- Vreden Russian Research Institute of Traumatology and Orthopedics; Mechnikov North-Western State Medical University
| | - I. I. Shubnyakov
- Vreden Russian Research Institute of Traumatology and Orthopedics
| | - A. O. Denisov
- Vreden Russian Research Institute of Traumatology and Orthopedics
| |
Collapse
|
18
|
Kurcz B, Lyons J, Sayeed Z, Anoushiravani AA, Iorio R. Osteolysis as it Pertains to Total Hip Arthroplasty. Orthop Clin North Am 2018; 49:419-435. [PMID: 30224004 DOI: 10.1016/j.ocl.2018.06.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Osteolysis is a long-term complication of total hip arthroplasty (THA). As the projected number of THAs performed annually increases, osteolysis will likely continue to occur. However, because of advancements in prosthesis design, metallurgy, and enhanced bearing surfaces, fewer revision THAs will be linked to osteolysis and aseptic loosening. Despite these improvements, no preventative therapies are currently available for the management of osteolysis other than removing and replacing the source of bearing wear.
Collapse
Affiliation(s)
- Brian Kurcz
- Division of Orthopaedic Surgery, Southern Illinois University, 701 North 1st Street, Springfield, IL 62781, USA
| | - Joseph Lyons
- Department of Surgery, Chicago Medical School, 3333 Green Bay Road, North Chicago, IL 60064, USA
| | - Zain Sayeed
- Department of Orthopaedic Surgery, Detroit Medical Center, 4201 Saint Antoine, Detroit, MI 48201, USA
| | - Afshin A Anoushiravani
- Division of Orthopaedic Surgery, Albany Medical Center, 43 New Scotland, Albany, NY, USA
| | - Richard Iorio
- Division of Orthopaedic Surgery, Albany Medical Center, 43 New Scotland, Albany, NY, USA.
| |
Collapse
|
19
|
Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening. Eur Radiol 2018; 29:1258-1266. [DOI: 10.1007/s00330-018-5717-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/18/2018] [Accepted: 08/14/2018] [Indexed: 02/06/2023]
|
20
|
Matuszak SJ, Galea VP, Connelly JW, Christiansen J, Muratoglu O, Malchau H. Periprosthetic acetabular radiolucency progression in mid-term follow-up of the articular surface replacement hip system. Arch Orthop Trauma Surg 2018; 138:1021-1028. [PMID: 29869689 DOI: 10.1007/s00402-018-2962-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Indexed: 01/22/2023]
Abstract
INTRODUCTION Recent registry studies show that aseptic loosening secondary to osteolysis is the second leading cause of hip implant failure in patients implanted with metal-on-metal (MoM) bearings. The primary aim of our study was to report on the progression of acetabular osteolysis during mid-term follow-up in patients treated with MoM hip resurfacing arthroplasty (HRA) and MoM total hip arthroplasty (THA). The secondary aim was to identify independent predictors of osteolytic lesion progression. MATERIALS AND METHODS A total of 805 patients (805 hips) were included in this study (541 MoM HRA, 264 MoM THA) from a prospective, international clinical registry of the Articular Surface Replacement Hip System. Patients were enrolled a median of 6.6 years from surgery. Osteolytic lesion progression was defined either as any lesion developing de novo, or as an existing lesion progressing from radiolucency to osteolysis during the study period (range 0.5-4.3 years). RESULTS The number of cases with any osteolysis or radiolucency was 21 (3.9%) for ASR HRA and 29 (11.0%) for ASR XL THA at enrollment and increased to 69 (12.8%) for ASR HRA and 41 (15.5%) for ASR XL THA after follow-up. Osteolytic lesion progression was found in 66 (12.2%) ASR HRA patients and 31 (11.7%) ASR XL THA patients. Multivariate models determined that lower acetabular version angle (OR 0.963, p = 0.011) and elevated whole blood chromium (OR 1.110, p = 0.044) were independent predictors of osteolytic lesion progression in ASR HRA. CONCLUSION We suggest that physicians of patients implanted with ASR HRA implants closely monitor patients with higher chromium levels and lower version angles, as they are at increased risk for osteolytic lesion progression, and we recommend annual radiographic follow-up on all patients with ASR implants.
Collapse
Affiliation(s)
- Sean J Matuszak
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA
| | - Vincent P Galea
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA
| | - James W Connelly
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA
| | - Janus Christiansen
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA.,Department of Orthopaedic Surgery, Harvard Medical School, 25 Shattuck St., Boston, MA, 02115, USA
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA.,Department of Orthopaedic Surgery, Harvard Medical School, 25 Shattuck St., Boston, MA, 02115, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Orthopaedic Department, Massachusetts General Hospital, 55 Fruit St. GRJ 1231, Boston, MA, 02114-2696, USA. .,Department of Orthopaedic Surgery, Harvard Medical School, 25 Shattuck St., Boston, MA, 02115, USA.
| |
Collapse
|
21
|
Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene. Clin Orthop Relat Res 2018; 476. [PMID: 29529656 PMCID: PMC6259699 DOI: 10.1007/s11999.0000000000000036] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Crosslinked polyethylene (XLPE) liners used for primary THA have demonstrated lower wear rates than noncrosslinked, conventional polyethylene (CPE) liners through the first decade of clinical service. However, little high-quality evidence is currently available regarding the second decade performance of these implants and it remains uncertain whether the onset of osteolysis has simply been delayed or if the wear associated with XLPE liners will remain low enough that osteolysis will not occur. It is also unknown how the potential reductions in wear and osteolysis will influence long-term revision rates. QUESTIONS/PURPOSES Do patients who underwent THA with XLPE liners demonstrate (1) a lower rate of revision for wear-related complications; (2) a reduced wear rate; and (3) a lower frequency of osteolysis compared with those with CPE liners? METHODS Over an 18-month period from 1999 to 2000, 226 patients who had 236 primary THAs consented to participate in a randomized controlled trial conducted at one institution. To be eligible for intraoperative randomization, patients had to be implanted with a 28-mm cobalt-chrome alloy femoral head, a 4-mm lateralized liner, and the same cup and stem design. Six patients with six THAs were excluded intraoperatively because they did not receive study components for reasons unrelated to the liner material. The remaining 230 THAs among 220 patients were randomized to XLPE liners or CPE liners. The mean age at surgery was 62 ± 11 years and there were no differences in age, gender, or body mass index among the groups. There was no differential loss to followup between the study groups; among patients not known to be deceased or having undergone revision, minimum 14-year radiographic followup is available for 85 THAs including 46 with XLPE and 39 with CPE liners. Polyethylene wear was measured radiographically using Martell's Hip Analysis Suite and areas of osteolysis were evaluated before revision or at most recent followup. Revision rates at 15 years using reoperation for any reason and revision for wear or osteolysis were calculated using cumulative incidence considering patient death as a competing risk. RESULTS The cumulative incidence of revision at 15 years using reoperation for wear-related complications as an endpoint was lower in the XLPE group than the CPE group (0%, 95% confidence interval [CI], 0%-0% versus 12%, 95% CI, 7%-19%; p < 0.001). Among unrevised THAs with minimum 14-year radiographic followup, the mean steady-state linear wear rate for THAs with XLPE liners was lower than the mean linear wear rate for the THAs with CPE liners (0.03 ± 0.05 versus 0.17 ± 0.09 mm/year; mean difference, 0.14; 95% CI, 0.11-0.17; p < 0.001). Osteolysis of any size was noted among 9% (four of 46) of the hips in the XLPE group and 46% (18 of 39) of the hips in the CPE group (odds ratio, 0.19; 95% CI, 0.07-0.51; p < 0.001). CONCLUSIONS This randomized study with followup into the second decade demonstrated reductions in revision, wear, and osteolysis associated with the use of XLPE. The low wear rates and absence of any mechanical failures among the XLPE liners at long-term followup affirm the durability of these components that did not incorporate antioxidants. Although osteolysis has not been eliminated, it occurs infrequently and has not caused any clinical problems to date. LEVEL OF EVIDENCE Level I, therapeutic study.
Collapse
|
22
|
Longitudinal morphological change of acetabular subchondral bone cyst after total hip arthroplasty in developmental dysplasia of the hip. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:621-625. [PMID: 29299764 DOI: 10.1007/s00590-017-2115-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 12/20/2017] [Indexed: 10/18/2022]
Abstract
PURPOSE The purpose of this study is to clarify morphological changes of acetabular subchondral bone cyst after total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip. METHODS Two hundred and sixty-one primary cementless total hip arthroplasties of 208 patients, 18 males, 190 females, were retrospectively reviewed. Morphological changes of subchondral bone cyst were evaluated by computed tomography (CT). The mean cross-sectional area of the cyst from CT scans at 3 months postoperatively and after 7-10 years (average 8.4 years) were compared. RESULTS Acetabular subchondral bone cysts were found in 49.0% of all cases in preoperative CT scans. There was no cyst which was newly recognized in CT scan performed after postoperative 7-10 years. All the cross-sectional areas of the cysts evaluated in this study were reduced postoperatively. CONCLUSIONS This study revealed that acetabular subchondral bone cysts do not increase or expand after total hip arthroplasty and indicated that the longitudinal morphological change of acetabular bone cysts in patients of developmental dysplasia of the hip do not influence long-term implant fixation in total hip arthroplasty.
Collapse
|
23
|
Acetabular defect classification in times of 3D imaging and patient-specific treatment protocols. DER ORTHOPADE 2017; 46:168-178. [PMID: 28078371 DOI: 10.1007/s00132-016-3378-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Parallel to the rising number of revision hip procedures, an increasing number of complex periprosthetic osseous defects can be expected. Stable long-term fixation of the revision implant remains the ultimate goal of the surgical protocol. Within this context, an elaborate preoperative planning process including anticipation of the periacetabular defect form and size and analysis of the remaining supporting osseous elements are essential. However, detection and evaluation of periacetabular bone defects using an unsystematic analysis of plain anteroposterior radiographs of the pelvis is in many cases difficult. Therefore, periacetabular bone defect classification schemes such as the Paprosky system have been introduced that use standardized radiographic criteria to better anticipate the intraoperative reality. Recent studies were able to demonstrate that larger defects are often underestimated when using the Paprosky classification and that the intra- and interobserver reliability of the system is low. This makes it hard to compare results in terms of defects being studied. Novel software tools that are based on the analysis of CT data may provide an opportunity to overcome the limitations of native radiographic defect analysis. In the following article we discuss potential benefits of these novel instruments against the background of the obvious limitations of the currently used native radiographic defect analysis.
Collapse
|
24
|
Mussmann B, Overgaard S, Torfing T, Traise P, Gerke O, Andersen PE. Agreement and precision of periprosthetic bone density measurements in micro-CT, single and dual energy CT. J Orthop Res 2017; 35:1470-1477. [PMID: 27600874 DOI: 10.1002/jor.23417] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 09/06/2016] [Indexed: 02/04/2023]
Abstract
The objective of this study was to test the precision and agreement between bone mineral density measurements performed in micro CT, single and dual energy computed tomography, to determine how the keV level influences density measurements and to assess the usefulness of quantitative dual energy computed tomography as a research tool for longitudinal studies aiming to measure bone loss adjacent to total hip replacements. Samples from 10 fresh-frozen porcine femoral heads were placed in a Perspex phantom and computed tomography was performed with two acquisition modes. Bone mineral density was calculated and compared with measurements derived from micro CT. Repeated scans and dual measurements were performed in order to measure between- and within-scan precision. Mean density difference between micro CT and single energy computed tomography was 72 mg HA/cm3 . For dual energy CT, the mean difference at 100 keV was 128 mg HA/cm3 while the mean difference at 110-140 keV ranged from -84 to -67 mg HA/cm3 compared with micro CT. Rescanning the samples resulted in a non-significant overall between-scan difference of 13 mg HA/cm3 . Bland-Altman limits of agreement were wide and intraclass correlation coefficients ranged from 0.29 to 0.72, while 95% confidence intervals covered almost the full possible range. Repeating the density measurements for within-scan precision resulted in ICCs >0.99 and narrow limits of agreement. Single and dual energy quantitative CT showed excellent within-scan precision, but poor between-scan precision. No significant density differences were found in dual energy quantitative CT at keV-levels above 110 keV. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1470-1477, 2017.
Collapse
Affiliation(s)
- Bo Mussmann
- Department of Radiology, Odense University Hospital, Sdr. Boulevard 29, 5000, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Søren Overgaard
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Sdr. Boulevard 29, 5000, Odense, Denmark
| | - Trine Torfing
- Department of Radiology, Odense University Hospital, Sdr. Boulevard 29, 5000, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Peter Traise
- Hunter New England Imaging, Armidale Hospital, Armidale, New South Wales, Australia
| | - Oke Gerke
- Department of Nuclear Medicine, Odense University Hospital, Sdr. Boulevard 29, 5000, Odense, Denmark.,Centre of Health Economics Research, University of Southern Denmark, Odense, Denmark
| | - Poul Erik Andersen
- Department of Radiology, Odense University Hospital, Sdr. Boulevard 29, 5000, Odense, Denmark.,Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
25
|
Takada R, Jinno T, Koga D, Miyatake K, Muneta T, Okawa A. Comparison of wear rate and osteolysis between second-generation annealed and first-generation remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at a minimum of five years. Orthop Traumatol Surg Res 2017; 103:537-541. [PMID: 28300705 DOI: 10.1016/j.otsr.2017.02.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 02/15/2017] [Accepted: 02/22/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND There is no previous report that directly compared wear resistance of second-generation annealed highly cross-linked polyethylene with that of first-generation remelted highly cross-linked polyethylene. We therefore performed a retrospective study at a minimum of 5-year follow-up comparing second-generation annealed and first-generation remelted highly cross-linked polyethylene in order to: (1) assess wear rates and (2) compare the incidence of osteolysis between, (3) identify the frequency of complication related to the two types of highly cross-linked polyethylene. HYPOTHESIS There is a difference in the linear wear rate and the incidence of osteolysis between the two types of highly cross-linked polyethylene in total hip arthroplasty. MATERIALS AND METHODS In a single centre study, we reviewed 123 primary cementless total hip arthroplasties between 2010 and 2011 that were performed with 32mm alumina ceramic on second-generation annealed (X3) or first-generation remelted (Longevity) highly cross-linked polyethylene liner. There was no specific reason for the choice of the type of highly cross-linked polyethylene. There were no significant differences between the two groups in respect of gender, diagnosis, body mass index, pre- and post-operative functional and activity score, cup size, and cup orientation except the younger age in the X3 group. The mean wear rate and the incidence of osteolysis were evaluated at the latest follow-up. RESULTS One hundred nine cases followed over 5 years post-operatively (88.6% in all consecutive cases) were evaluated. X3 and Longevity were used in 54 and 55 cases, respectively. The mean follow-up was 5.3 years in both groups. The mean linear wear rate of X3 and Longevity group was 0.045±0.023mm/year and 0.076±0.031mm/year, respectively (P<0.001). No osteolysis was found on plain X-rays in both groups and no specific complication was related to these highly cross-linked components. DISCUSSION Excellent wear resistance of both types of highly cross-linked polyethylene liner was revealed in our study. The difference of wear rate between two materials should be monitored in a longer follow-up. LEVEL OF EVIDENCE Level III retrospective case control study.
Collapse
Affiliation(s)
- R Takada
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
| | - T Jinno
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| | - D Koga
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
| | - K Miyatake
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
| | - T Muneta
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
| | - A Okawa
- Department of Orthopaedic Surgery, Medical Hospital, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan
| |
Collapse
|
26
|
Broomfield JAJ, Malak TT, Thomas GER, Palmer AJR, Taylor A, Glyn-Jones S. The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort. J Arthroplasty 2017; 32:1186-1191. [PMID: 27998657 DOI: 10.1016/j.arth.2016.10.037] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 10/24/2016] [Accepted: 10/28/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. METHODS Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. RESULTS Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. CONCLUSION This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene.
Collapse
Affiliation(s)
- John A J Broomfield
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Tamer T Malak
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Geraint E R Thomas
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Antony J R Palmer
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Adrian Taylor
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Sion Glyn-Jones
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| |
Collapse
|
27
|
Kim YH, Park JW, Kim JS. Long-Term Results of Third-Generation Ceramic-on-Ceramic Bearing Cementless Total Hip Arthroplasty in Young Patients. J Arthroplasty 2016; 31:2520-2524. [PMID: 27172862 DOI: 10.1016/j.arth.2016.03.058] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Revised: 03/11/2016] [Accepted: 03/30/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The results of third-generation of alumina-on-alumina ceramic bearing in a large number of patient cohorts are limited. The purpose of this study was to determine clinical and radiologic outcome, prevalence of osteolysis detected with radiographs and computerized tomographic scan, and survivorship of a cementless total hip arthroplasty using a third-generation of alumina-on-alumina ceramic bearing in a large number of active patients aged younger than 65 years. METHODS We reviewed the cases of 871 patients (1131 hips) who underwent a cementless total hip arthroplasty when they were aged 65 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (53%) and osteoarthritis (20%). Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. The mean follow-up interval was 18.8 years (range, 15-20 years). RESULTS At the time of final follow-up, the mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 90 points, 15 points, and 8 points, respectively. All the femoral stem and acetabular components were well-fixed at the time of final follow-up. No hip had aseptic loosening or osteolysis or fracture of ceramic material at the time of the final follow-up. CONCLUSION The current results with the use of the third-generation of alumina-on-alumina ceramic bearings in young patients suggest that cementless acetabular and femoral components provide outstanding long-term fixation and provide a high rate of survivorship without evidence of osteolysis.
Collapse
Affiliation(s)
- Young-Hoo Kim
- The Joint Replacement Center, Ewha Womans University School of Medicine, SeoNam Hospital, Seoul, Republic of Korea
| | - Jang-Won Park
- The Joint Replacement Center, Ewha Womans University School of Medicine, MokDong Hospital, Seoul, Republic of Korea
| | - Jun-Shik Kim
- The Joint Replacement Center, Ewha Womans University School of Medicine, MokDong Hospital, Seoul, Republic of Korea
| |
Collapse
|
28
|
Comparison of wear rate and osteolysis between annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at 7 to 10 years follow-up. Orthop Traumatol Surg Res 2016; 102:717-21. [PMID: 27291079 DOI: 10.1016/j.otsr.2016.04.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 04/22/2016] [Accepted: 04/27/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND Low polyethylene wear rate and low incidence of osteolysis after total hip arthroplasty using annealed and remelted highly cross-linked polyethylene have been reported. However, there is no previous report that directly compared both types of highly cross-linked polyethylene. We therefore performed a retrospective study on a series of highly cross-linked polyethylene, in order to: (1) compare wear rates and the incidence of osteolysis between annealed and remelted highly cross-linked polyethylene at 7-10 years; (2) identify the frequency of complication related to annealed and remelted highly cross-linked polyethylene. HYPOTHESIS There is no difference in the linear wear rate and the incidence of osteolysis between the annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. PATIENTS AND METHODS Two hundred and sixteen cases of cementless total hip arthroplasties with annealed or remelted highly cross-linked polyethylene, which were performed between January 2003 and December 2006 in one institution, were followed for 7-10 years and received computed tomography scan, in addition to radiography at the latest follow-up. Annealed and remelted highly cross-linked polyethylene was used in 91 cases and 125 cases, respectively. A 26-mm cobalt-chromium head was used in all cases. Penetration rates from 1 year to the last evaluation were used to estimate the yearly linear wear rate. Existence of osteolysis was evaluated by plain radiography and computed tomography. RESULTS There were no significant differences in patients' background between the two groups. The linear wear rate of annealed and remelted group was 0.031±0.022mm/year and 0.032±0.020mm/year, respectively (P=0.91). Two cases of small femoral osteolysis were found in the annealed group. Any complication related to highly cross-linked polyethylene was not found in both groups. DISCUSSION There was no significant difference in the linear wear rate and the incidence of osteolysis between the annealed and remelted group at postoperative 7 to 10 years. Excellent results of both types of highly cross-linked polyethylene were revealed by this study. LEVEL OF EVIDENCE Level III retrospective case control study.
Collapse
|
29
|
Tsukanaka M, Halvorsen V, Nordsletten L, EngesæTer IØ, EngesæTer LB, Marie Fenstad A, Röhrl SM. Implant survival and radiographic outcome of total hip replacement in patients less than 20 years old. Acta Orthop 2016; 87:479-84. [PMID: 27435903 PMCID: PMC5016906 DOI: 10.1080/17453674.2016.1212180] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Total hip replacement (THR) is not recommended for children and very young teenagers because early and repetitive revisions are likely. We investigated the clinical and radiographic outcomes of THR performed in children and teenage patients. Patients and methods - We included 111 patients (132 hips) who underwent THR before 20 years of age. They were identified in the Norwegian Arthroplasty Register, together with information on the primary diagnosis, types of implants, and any revisions that required implant change. Radiographs and Harris hip score (HHS) were also evaluated. Results - The mean age at primary THR was 17 (11-19) years and the mean follow-up time was 14 (3-26) years. The 10-year survival rate after primary THR (with the endpoint being any revision) was 70%. 39 patients had at least 1 revision and 16 patients had 2 or more revisions. In the latest radiographs, osteolysis and atrophy were observed in 19% and 27% of the acetabulae and 21% and 62% of the femurs, respectively. The mean HHS at the final follow-up was 83 (15-100). Interpretation - The clinical score after THR in these young patients was acceptable, but many revisions had been performed. However, young patients with developmental dysplasia of the hip had lower implant survival. Moreover, the bone stock in these patients was poor, which could complicate future revisions.
Collapse
Affiliation(s)
- Masako Tsukanaka
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo;,Correspondence:
| | - Vera Halvorsen
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo
| | - Lars Nordsletten
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo
| | - Ingvild Ø EngesæTer
- The Norwegian Arthroplasty Register, Haukeland University Hospital, Bergen, Norway
| | - Lars B EngesæTer
- The Norwegian Arthroplasty Register, Haukeland University Hospital, Bergen, Norway
| | - Anne Marie Fenstad
- The Norwegian Arthroplasty Register, Haukeland University Hospital, Bergen, Norway
| | - Stephan M Röhrl
- Department of Orthopaedic Surgery, Oslo University Hospital, Oslo
| |
Collapse
|
30
|
Abstract
PURPOSE Promising clinical results and survival rates have been reported for the Bi-Metric proximally hydroxyapatite (HA)-coated femoral stem in short- and mid-term studies. In this study we evaluated the long-term survival as well as clinical and radiological results of this stem. METHODS From 1992 to 1998 we prospectively included 112 consecutive patients who received a total hip arthroplasty (THA) with an uncemented proximally HA-coated Bi-Metric femoral component (Biomet).At 3 months, 1 year and thereafter every 2 to 3 years, patients were clinically and radiologically monitored. Primary endpoint was revision of the stem for any reason. Secondary endpoints were survival of the cup and THA, radiological characteristics and clinical scores (HHS, HOOS, SF-36 and VAS). RESULTS Median follow-up was 20 (16-22.25) years. Median age at surgery was 52 (22-63) years. At final follow-up, survival analysis showed an all-cause stem survival of 96.8% (95% CI, 93.3-100). Median HHS scores improved from 57 preoperatively to 94 at final follow-up (p<0.001). At final follow-up the median HOOS score was 80 (9-100); median SF-36 score 71 (18-100); median VAS pain score at rest 0 (0-6) and during activity 0 (0-10). CONCLUSIONS In this prospective cohort study the 20-year survival rate of the Bi-Metric proximally HA-coated femoral stem was excellent.
Collapse
|
31
|
Takada R, Jinno T, Koga D, Yamauchi Y, Asou Y, Muneta T, Okawa A. Limited significance of screening computed tomography after cementless total hip arthroplasty with highly cross-linked polyethylene at 7-10 years of follow-up. Mod Rheumatol 2015; 26:757-60. [PMID: 26708312 DOI: 10.3109/14397595.2015.1131136] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVES The purpose of this retrospective study is to report the incidence of osteolysis and evaluate the significance of screening computed tomography (CT) compared to plain radiography in detecting osteolysis after total hip arthroplasty with metal-on-highly cross-linked polyethylene bearings. METHODS We retrospectively reviewed 264 primary cementless total hip arthroplasties of 211 patients, 24 males, 187 females, who received postoperative screening CT scan in addition to radiography at postoperative 7-10 years (average 8.2 years). First-generation highly cross-linked polyethylene was used in all cases. RESULTS On the plain radiographs, no acetabular osteolysis (0%) and two cases of femoral osteolysis (0.8%) were found in the follow-up period. No osteolysis was newly found by screening CT scan. CONCLUSIONS Very low incidence of osteolysis after total hip arthroplasty with highly cross-linked polyethylene at postoperative 7-10 years was confirmed, and routine screening CT scan for detecting osteolysis in this setting was not supported from this study.
Collapse
Affiliation(s)
- Ryohei Takada
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Tetsuya Jinno
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Daisuke Koga
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Yuki Yamauchi
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Yoshinori Asou
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Takeshi Muneta
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| | - Atsushi Okawa
- a Department of Orthopaedic Surgery , Medical Hospital, Tokyo Medical and Dental University , Tokyo , Japan
| |
Collapse
|
32
|
Moon KH, Kang JS, Won MH, Park MJ, Choi JH. The Usefulness of Three-dimensional Computed Tomography as an Assessment of Periacetabular Osteolysis in Revision Total Hip Arthroplasty. Hip Pelvis 2015; 27:90-7. [PMID: 27536609 PMCID: PMC4972632 DOI: 10.5371/hp.2015.27.2.90] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Revised: 04/10/2015] [Accepted: 04/28/2015] [Indexed: 11/24/2022] Open
Abstract
Purpose This study was performed to determine the usefulness of three-dimensional computed tomography (3D-CT) in measuring periacetabular osteolysis by comparing the real volume of osteolysis in revision surgery. Materials and Methods Twnety-three patients who had undergone revision surgery due to periacetabular osteolysis but not included septic osteolysis and implant loosening. The mean age of patients at the time of surgery was 55.2 years. And the mean time interval between the primary total hip arthroplasty and revision surgery was 13.3 years. We measured the polyethylene wear in plain radiographs using computer assisted vector wear analysis program, the volume of acetabular osteolytic lesions in high-resolution spiral CT scans using Rapidia 3D software version 2.8 algorithms before the revision surgery were performed. Intraoperative real osteolytic volume was calculated as the sum of the volumetric increments of the acetabular cup and impacted allo-cancellous bone volume. Results Strong correlation was found between the volume of acetabular osteolytic lesions measured on 3D-CT and intraoperative real osteolytic volume which was calculated as the sum of the volumetric increments of the acetabular cup and impacted allo-cancellous bone volume. Conclusion 3D-CT is considered a useful method for assessing and measuring the volume of periacetabular osteolysis before revision surgery.
Collapse
Affiliation(s)
- Kyoung Ho Moon
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Joon Soon Kang
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Man Hee Won
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Myoung Joo Park
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Jae Hwang Choi
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| |
Collapse
|
33
|
Tsukada S, Wakui M. Lower Dislocation Rate Following Total Hip Arthroplasty via Direct Anterior Approach than via Posterior Approach: Five-Year-Average Follow-Up Results. Open Orthop J 2015; 9:157-62. [PMID: 26157532 PMCID: PMC4483535 DOI: 10.2174/1874325001509010157] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 03/25/2015] [Accepted: 04/20/2015] [Indexed: 01/28/2023] Open
Abstract
Objective: The aim of the study was to compare the dislocation rate between total hip arthroplasty (THA) via direct anterior approach (DAA) and via posterior approach (PA). Methods: We compared a consecutive series of 139 THAs via DAA with 177 THAs via PA. All study patients received ceramic-on-ceramic bearing surfaces and similar uncemented prostheses. Dislocation-free survival after THA was estimated using the Kaplan–Meier survival method and compared between groups using the log-rank test. Results: In the DAA group, none of 139 hips experienced dislocations in five-year-average follow-up. In the PA group, seven hips experienced dislocations among 177 hips (4 %). The dislocation was significantly less in the DAA group compared to the PA group (p = 0.033). Conclusion: The dislocation rate of THA via DAA was significantly less than that of THA via PA.
Collapse
Affiliation(s)
- Sachiyuki Tsukada
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo-ku, Niigata, Niigata, 950-1151, Japan
| | - Motohiro Wakui
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo-ku, Niigata, Niigata, 950-1151, Japan
| |
Collapse
|
34
|
Epinette JA. Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplasty 2015; 30:241-8. [PMID: 25449593 DOI: 10.1016/j.arth.2014.09.022] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 08/18/2014] [Accepted: 09/22/2014] [Indexed: 02/01/2023] Open
Abstract
The principle of dual mobility cups, often called "tripolar", has been developed to overcome the problem of instability following primary hip arthroplasty. We prospectively compared two cohorts which differed only by the type of bearings, i.e." mobile bearing hip" (MBH) in a 143-study cohort of ADM cups versus "fixed bearing hip" (FBH) of 130 Trident PSL cups, at a follow-up at 2-6years. The survival rates at 4.13-years, with instability as endpoint was significantly (P=0.0176) in favor of mobile bearings at 100% with no dislocation reported, versus 94.8% with fixed bearings. These mobile bearings, matching both "modern" dual mobility cups and annealed highly crossed polyethylene, would appear to offer at longer follow-up a valuable solution to clinical outcomes in acetabular arthroplasty.
Collapse
Affiliation(s)
- Jean-Alain Epinette
- Orthopaedic Research and Imaging Centre in Arthroplasty, Clinique Médico-Chirurgicale, Bruay-Labuissière, France
| |
Collapse
|
35
|
Influence of clinical and radiological variables on the extent and distribution of periprosthetic osteolysis in total hip arthroplasty with a hydroxyapatite-coated multiple-hole acetabular component: a magnetic resonance imaging study. J Arthroplasty 2014; 29:2043-8. [PMID: 24986509 DOI: 10.1016/j.arth.2014.05.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Revised: 04/17/2014] [Accepted: 05/22/2014] [Indexed: 02/01/2023] Open
Abstract
Polyethylene wear-induced osteolysis constitutes the most severe long-term complication of total hip arthroplasties (THA). Our aim was to assess through MRI the severity and growth pattern of osteolysis, as well as the influence clinical-radiographic variables exert. We analyzed 75 THA with an average evolution time of 13.67years. The implant was a titanium alloy, non-cemented, multiple-hole model with hydroxyapatite coating. Osteolysis was found with a peripheral pattern in 48 and a central pattern in 6; in 52 cases it was continuous, and in 4, isolated. Out of 118 screws, 20 exhibited lysis. There was a proportional correlation between osteolysis severity and wear rate with age, physical activity and acetabular abduction, as well as an association between said variables and peripheral and continuous patterns.
Collapse
|
36
|
No differences found in bearing related hip survivorship at 10-12 years follow-up between patients with ceramic on highly cross-linked polyethylene bearings compared to patients with ceramic on ceramic bearings. J Arthroplasty 2014; 29:1369-72. [PMID: 24674733 DOI: 10.1016/j.arth.2014.02.025] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 01/09/2014] [Accepted: 02/18/2014] [Indexed: 02/01/2023] Open
Abstract
At a minimum follow-up of ten years we compared clinical and radiographic findings and survivorship in a cohort of 412 patients (447 hips) who received alumina on alumina CoC bearings to findings from a cohort of 216 patients (228 hips) with alumina on highly cross-linked polyethylene (HXLPE) bearings. All patients were operated for osteoarthritis. With bearing-related complications as endpoint, analysis showed no significant difference in survivorship between cohorts (99.8% for the CoC vs. 99.4% for HXLPE). In addition, there were no significant differences in clinical and radiographic findings between cohorts. We concluded that alumina on HXLPE bearings are a reasonable lower cost alternative to ceramic on ceramic bearing couples.
Collapse
|
37
|
Elevation of serum tumor necrosis factor α in patients with periprosthetic osteolysis: a case-control study. Clin Orthop Relat Res 2014; 472:584-9. [PMID: 24307062 PMCID: PMC3890206 DOI: 10.1007/s11999-013-3235-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Periprosthetic osteolysis is the leading reason for THA revision. The relationship of serum biomarkers with severe radiographic periprosthetic osteolysis has not been defined but may be important to direct future research and clinical therapeutics. QUESTIONS/PURPOSES We determined whether there was an association between measurable inflammatory markers (high-sensitivity C-reactive protein [hsCRP]) or inflammatory mediators (tumor necrosis factor α [TNF-α], IL-1β, IL-6, receptor activator of nuclear factor κB ligand [RANKL], and osteoprotegerin [OPG]) and periprosthetic osteolysis. METHODS We identified 15 patients with THAs scheduled for revision surgery because of severe periprosthetic osteolysis. For each study patient, a nonosteolytic, pain-free control patient with THAs was identified and matched for age, sex, time since initial THA, acetabular and femoral component prosthesis material, and prosthesis wear within 1.0 mm/year using a manual wear analysis technique. Overall, the study and control patients had a mean wear rate of 0.25 mm/year since index THA. There were no differences in baseline characteristics between study and control patients in age, sex, BMI, Charlson Comorbidity Index, time since initial THA, UCLA activity score, and acetabular and femoral component type. Serum hsCRP, IL-1β, IL-6, TNF-α, RANKL, and OPG were measured by ELISA in duplicate assays. Differences in values were assessed using the Wilcoxon rank-sum test. RESULTS Median TNF-α levels were higher in study patients than in controls (7.1 pg/mL [SD, 11.6 pg/mL] versus 1.5 pg/mL [SD, 1.3 pg/mL]) (p < 0.01). Median IL-6 levels tended to be higher in study patients than in controls (8.9 pg/mL [SD, 13.2 pg/mL] versus 3.5 pg/mL [SD, 0.7 pg/mL]) (p = 0.09). The other serum inflammatory proteins and mediators of bone turnover were not different between groups. CONCLUSIONS TNF-α is elevated in patients with osteolysis compared to matched controls. The role of TNF-α and its potential as a target of nonsurgical therapy to prevent osteolysis warrant further investigation in larger, prospective studies.
Collapse
|
38
|
Waldstein W, Schmidt-Braekling T, Boettner F. MRI does not detect acetabular osteolysis around metal-on-metal Birmingham THA. Arch Orthop Trauma Surg 2014; 134:1009-15. [PMID: 24838248 PMCID: PMC4062806 DOI: 10.1007/s00402-014-2005-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Osteolysis has not been recognized as a common failure mode of the Birmingham modular metal-on-metal (MoM) total hip arthroplasty (THA). The clinical value of metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) to assess the periprosthetic soft tissue is well documented; however, the appropriate image modalities to detect periacetabular osteolysis remain unclear. Eleven patients with periacetabular osteolysis within 3-6 years after uncemented Birmingham modular MoM THA with a synergy stem are presented. All 11 patients received corresponding standardized AP pelvis radiographs, high-quality MARS MRIs and CT scans with a metal artifact reduction sequence. While periacetabular osteolysis around MoM THA was not detected on MARS MRI in ten patients, CT imaging identified osteolysis in all patients. Periacetabular osteolysis appears to be a failure mechanism of the Smith & Nephew Birmingham MoM THA. DISCUSSION There is no evidence in the literature to support the effectiveness of MARS MRI to detect periacetabular osteolysis around cobalt chromium alloy metal-on-metal total hip arthroplasties. Osteolysis due to corrosion-related particles seems to be one of the primary modes of failure in modular MoM THA. CONCLUSIONS MRI is not a sensitive test to identify periacetabular osteolysis. The authors recommend CT for the screening of implants with this failure mode. Our study suggests that patients with a Birmingham modular MoM THA are at increased risk to develop acetabular osteolysis and should be carefully monitored for this failure mode.
Collapse
Affiliation(s)
- Wenzel Waldstein
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 East 70th Street, New York, NY 10021 USA
| | - Tom Schmidt-Braekling
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 East 70th Street, New York, NY 10021 USA
| | - Friedrich Boettner
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, Weill Medical College of Cornell University, 535 East 70th Street, New York, NY 10021 USA
| |
Collapse
|
39
|
Randelli F, Banci L, Favilla S, Maglione D, Aliprandi A. Radiographically undetectable periprosthetic osteolysis with ASR implants: the implication of blood metal ions. J Arthroplasty 2013; 28:1259-64. [PMID: 23528557 DOI: 10.1016/j.arth.2013.02.019] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 02/11/2013] [Accepted: 02/17/2013] [Indexed: 02/01/2023] Open
Abstract
Patients with ASR implants (resurfacing and large-diameter (XL) metal-on-metal (MoM) total hip arthroplasty), even if asymptomatic and with a stable prosthesis, may present extremely high blood metal ion levels. We report on a consecutive series of fourteen ASR revisions, focusing on osteolysis and their radiographic correspondence and their correlation with blood metal ion levels. At revision, seven hips revealed severe periacetabular osteolysis which was radiographically undetectable in six and asymptomatic in five. Seven hips with no acetabular osteolysis had significantly lower serum Cr and Co ion concentrations (respectively 25.2, 41.1 μg/l) compared to the seven hips with severe acetabular bone loss (respectively 70.1, 147.0 μg/l). Elevated blood metal ion levels should be considered as a warning of undetectable and ongoing periprosthetic osteolysis in asymptomatic patients with ASR prosthesis.
Collapse
Affiliation(s)
- Filippo Randelli
- 5th Orthopaedic Department (Department of Hip Surgery), Policlinico San Donato, Milan, Italy
| | | | | | | | | |
Collapse
|
40
|
Tsukada S, Wakui M, Matsueda M. Uncemented third-generation ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner. Arch Orthop Trauma Surg 2013; 133:861-8. [PMID: 23508514 DOI: 10.1007/s00402-013-1724-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Indexed: 11/28/2022]
Abstract
BACKGROUND The ceramic-on-ceramic (CoC)-bearing couple in total hip arthroplasty (THA) was developed to reduce the wear debris and osteolysis. Although the mechanical strength of third-generation ceramic has improved over previous generations, the risk of osteolysis and ceramic fracture is still an important concern. METHODS We studied 124 uncemented THAs with third-generation CoC-bearing couple implanted between 2000 and 2004. The ceramic liner and head were secured with the direct taper locking mechanism. One hundred and eleven hips were followed-up for minimum of 8 years, with an average follow-up period of 10.1 years (range 8.0-12.8 years). Patients were evaluated with a particular emphasis on the prevalence of the osteolysis and the ceramic fracture. RESULTS The survivorship with the end point as implant revision for any reason was 94.9 % (95 % confidence intervals 90.0-99.3 %) at 12.8 years. Revisions were performed because of one ceramic liner fracture, three dislocations, and two deep infections. No radiographic evidence of wear or osteolysis was observed. The preoperative Merle d'Aubigne and Postel hip score increased from 11.6 to 17.1. CONCLUSIONS Patients, who received third-generation CoC THA had no detectable wear and osteolysis. One ceramic fracture occurred, and the main reason for revision was dislocation.
Collapse
Affiliation(s)
- Sachiyuki Tsukada
- Department of Orthopaedic Surgery, Nekoyama Miyao Hospital, 14-7 Konan, Chuo-ku, Niigata, Niigata, 950-1151, Japan.
| | | | | |
Collapse
|
41
|
Safir O, Lin C, Kosashvili Y, Mayne IP, Gross AE, Backstein D. Limitations of conventional radiographs in the assessment of acetabular defects following total hip arthroplasty. Can J Surg 2013; 55:401-7. [PMID: 22992397 DOI: 10.1503/cjs.000511] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Conventional radiographs are routinely used to evaluate acetabular bone loss as part of the follow-up in patients who undergo total hip arthroplasty (THA). The objective of this study was to examine the accuracy and specificity of conventional radiographs reviewed by arthroplasty surgeons in detecting acetabular bone loss in patients with prior THA. METHODS Using a cadaveric pelvic model, a defined percentage of bone was incrementally removed from the posterior acetabular column, followed by implantation of uncemented cups into both acetabula. Ten orthopedic arthroplasty surgeons, blinded to the defect sizes, assessed the percentage of bone defect using standard anteroposterior, Judet and oblique conventional radiographs. RESULTS Observers were unable to accurately grade bone defects using conventional radiographs. For defects less than 50%, observers reported on average a defect of 11%. Although observer estimates of defects 50% or more increased, these treatment-altering bone deficiencies remained grossly underestimated, with a sensitivity and specificity of 36.6% and 97.6%, respectively. CONCLUSION Conventional radiographs reviewed by experienced arthroplasty surgeons do not reliably detect small bone lesions (< 50%). Although more successful in detecting larger bone lesions, surgeons tend to underestimate actual bone loss. Computed tomography scanning may be indicated if accurate estimation of acetabular bone loss is required in patients who have undergone previous THA.
Collapse
Affiliation(s)
- Oleg Safir
- The Arthroplasty Division, Orthopedic Department, Mount Sinai Hospital, Toronto, Ont
| | | | | | | | | | | |
Collapse
|
42
|
Poultsides LA, Sioros V, Anderson JA, Bruni D, Beksac B, Sculco TP. Ten- to 15-year clinical and radiographic results for a compression molded monoblock elliptical acetabular component. J Arthroplasty 2012; 27:1850-6. [PMID: 23146368 DOI: 10.1016/j.arth.2012.05.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Accepted: 05/14/2012] [Indexed: 02/01/2023] Open
Abstract
The aim of this study was to report the long-term results from a previously published midterm follow-up of a titanium monoblock, elliptical acetabular component. A total of 258 primary total hip arthroplasties (212 patients) with a monoblock, acetabular component were followed up for a mean period of 11.1 years (10-15). Average yearly wear rate was 0.08 mm/y (0.0009-0.32). Acetabular radiolucencies were present in 6 hips (2.4%); all were nonprogressive and present in acetabular zone I. Acetabular osteolysis was present in 5 patients (5 hips, 1.9%); all cups were stable. Four acetabular components were revised, 3 because of recurrent instability. No acetabular components were revised for polyethylene wear or dissociation, acetabular osteolysis, loosening, or deep infection. This monoblock design demonstrates excellent long-term survival and low rate of osteolysis.
Collapse
Affiliation(s)
- Lazaros A Poultsides
- Division of Adult Reconstruction and Joint Replacement, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | | | | | | | | | | |
Collapse
|
43
|
Howie DW, Neale SD, Martin W, Costi K, Kane T, Stamenkov R, Findlay DM. Progression of periacetabular osteolytic lesions. J Bone Joint Surg Am 2012; 94:e1171-6. [PMID: 22992823 DOI: 10.2106/jbjs.k.00877] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The development of three-dimensional computed tomography (CT) imaging techniques has enabled the detection, accurate measurement, and monitoring of periprosthetic osteolytic lesions. The aim of this study was to track the progression in size of osteolytic lesions and to determine those factors that are associated with the risk of progression. A secondary aim was to investigate whether progression in size of osteolytic lesions could be monitored with use of radiographs. METHODS We retrospectively determined, with use of sequential CT scans, the progression of periacetabular osteolysis over a period of as much as nine years in a cohort of twenty-six patients (thirty acetabular components) in whom the cementless acetabular component or components had been in place for longer than ten years at the time of the initial CT scan. High-resolution CT scans with metal-artifact suppression were used to determine the volume of osteolytic lesions. Progression in the size of osteolytic lesions per year was calculated as the change in the volume of osteolytic lesions between serial CT scans. Associations were determined between the progression in size of osteolytic lesions, osteolysis rate at the initial CT, patient age, sex, walking limitations, and activity level. Progression in size of osteolytic lesions as determined with use of CT was compared with that determined with use of radiographs. RESULTS Mean progression in the size of osteolytic lesions, as determined with use of CT, was 1.5 cm(3)/yr (range, 0 to 7.5 cm(3)/yr). The amount of osteolysis at the initial CT scan and patient activity were good predictors of osteolytic lesion progression. The strongest predictor of osteolytic lesion progression occurred when these two risk factors were combined (p = 0.0019). The value of radiographs was limited to monitoring of larger lesions identified by CT. CONCLUSIONS This is the first study to report on the progression of osteolysis adjacent to cementless acetabular components from medium to long-term follow-up. The data suggest that the osteolysis rate at the initial CT and patient activity can be useful factors in predicting the progression in size of periacetabular osteolytic lesions.
Collapse
Affiliation(s)
- Donald W Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, North Terrace, Australia
| | | | | | | | | | | | | |
Collapse
|
44
|
Sariali E, Mouttet A, Mordasini P, Catonné Y. High 10-year survival rate with an anatomic cementless stem (SPS). Clin Orthop Relat Res 2012; 470:1941-9. [PMID: 22402808 PMCID: PMC3369068 DOI: 10.1007/s11999-012-2300-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2011] [Accepted: 02/20/2012] [Indexed: 01/31/2023]
Abstract
BACKGROUND Proximal cementless fixation using anatomic stems reportedly increases femoral fit and avoids stress-shielding. However, thigh pain was reported with the early stem designs. Therefore, a new anatomic cementless stem design was based on an average three-dimensional metaphyseal femoral shape. However, it is unclear whether this stem reduces the incidence of thigh pain. QUESTIONS/PURPOSES We asked whether this stem design was associated with a low incidence of thigh pain and provided durable fixation and high function. METHODS One hundred seventy-one patients (176 THAs) who had the anatomic proximal hydroxyapatite-coated stem implanted were reviewed. Eleven (6%) patients were lost to followup and 34 (20%) died without revision surgery. We used the Harris hip score (HHS) to assess pain and function. We evaluated femoral stem fixation and stability with the score of Engh et al. and also calculated a 10-year survival analysis. We assessed 126 patients (131 hips) at a mean followup of 10 years (range, 8-11 years) RESULTS At last followup, two patients described slight thigh pain that did not limit their physical activities. All stems appeared radiographically stable and one stem was graded nonintegrated but stable. Five patients had revision surgery: one on the femoral side (for posttraumatic fracture) and four on the acetabular side. Considering stem revision for aseptic loosening as the end point, survivorship was 100% (range, 95.4%-99.9%) at 10 years. CONCLUSION This anatomic cementless design using only metaphyseal fixation with a wide mediolateral flare, a sagittal curvature, and torsion, allowed durable proximal stem stability and fixation.
Collapse
Affiliation(s)
- Elhadi Sariali
- Department of Orthopaedic Surgery, Hôpital Pitié Salpétrière, 47-83 Bd de l’Hôpital, 75013 Paris, France
| | - Alexandre Mouttet
- Department of Orthopaedic Surgery, Clinique Saint Roch, Perpignan, France
| | - Philippe Mordasini
- Department of Orthopaedic Surgery, Clinique Bois-Cerf, Lausanne, Switzerland
| | - Yves Catonné
- Department of Orthopaedic Surgery, Hôpital Pitié Salpétrière, 47-83 Bd de l’Hôpital, 75013 Paris, France
| |
Collapse
|
45
|
Bulk femoral head autograft without decortication in uncemented total hip arthroplasty: seven- to ten-year results. J Arthroplasty 2012; 27:437-444.e1. [PMID: 21831577 DOI: 10.1016/j.arth.2011.06.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2010] [Accepted: 06/02/2011] [Indexed: 02/01/2023] Open
Abstract
Superolateral acetabular bone defect is a serious challenge in uncemented total hip arthroplasty for acetabular dysplasia. We report a bulk bone autografting technique without decortication of the acetabulum and femoral head contact surfaces in 22 joints. Mean follow-up time was 8.3 years, and survival rates were 100% for loosening and revision end points. The preoperative Japanese orthopedic association hip score increased from 49.5 to 94.0. Although trabecular bridging and graft remodeling occurred in all cases, complete trabecular reorientation was observed in only 15 joints. Eccentric polyethylene wear was observed in 8 of 22 joints, and osteolysis, in 1 joint. Our technique is easy to perform, and midterm results were favorable; thus, we conclude that it may be an effective option for bulk bone autografting.
Collapse
|
46
|
Long SS, Surrey D, Nazarian LN. Common sonographic findings in the painful hip after hip arthroplasty. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:301-312. [PMID: 22298875 DOI: 10.7863/jum.2012.31.2.301] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Diagnosing the cause of hip pain in patients with hip arthroplasty can be challenging because of the numerous possible causes of pain and artifacts caused by the prosthetic components on computed tomography and magnetic resonance imaging. Sonography plays an important role in the diagnosis and management of these patients because the soft tissues surrounding the prosthetic joint are not obscured by artifacts and because sonography enables hands-on examination of the painful site, dynamic evaluation of moving structures, and comparison with the opposite side. Another advantage of sonography is the ability to perform sonographically guided diagnostic and therapeutic procedures. In this pictorial essay, we highlight commonly encountered sonographic findings in patients with hip pain after hip arthroplasty.
Collapse
Affiliation(s)
- Suzanne S Long
- Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, Suite 796C, Philadelphia, PA 19107, USA.
| | | | | |
Collapse
|
47
|
Measuring femoral lesions despite CT metal artefacts: a cadaveric study. Skeletal Radiol 2012; 41:547-55. [PMID: 21732221 PMCID: PMC3310131 DOI: 10.1007/s00256-011-1223-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Revised: 06/12/2011] [Accepted: 06/13/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Computed tomography is the modality of choice for measuring osteolysis but suffers from metal-induced artefacts obscuring periprosthetic tissues. Previous papers on metal artefact reduction (MAR) show qualitative improvements, but their algorithms have not found acceptance for clinical applications. We investigated to what extent metal artefacts interfere with the segmentation of lesions adjacent to a metal femoral implant and whether metal artefact reduction improves the manual segmentation of such lesions. MATERIALS AND METHODS We manually created 27 periprosthetic lesions in 10 human cadaver femora. We filled the lesions with a fibrotic interface tissue substitute. Each femur was fitted with a polished tapered cobalt-chrome prosthesis and imaged twice--once with the metal, and once with a substitute resin prosthesis inserted. Metal-affected CTs were processed using standard back-projection as well as projection interpolation (PI) MAR. Two experienced users segmented all lesions and compared segmentation accuracy. RESULTS We achieved accurate delineation of periprosthetic lesions in the metal-free images. The presence of a metal implant led us to underestimate lesion volume and introduced geometrical errors in segmentation boundaries. Although PI MAR reduced streak artefacts, it led to greater underestimation of lesion volume and greater geometrical errors than without its application. CONCLUSION CT metal artefacts impair image segmentation. PI MAR can improve subjective image appearance but causes loss of detail and lower image contrast adjacent to prostheses. Our experiments showed that PI MAR is counterproductive for manual segmentation of periprosthetic lesions and should be used with care.
Collapse
|
48
|
Olof S, Mats S, Olle M, Ake J, Torbjörn A, Henrik B. The Ringloc liner compared with the Hexloc liner in total hip arthroplasty. Orthop Rev (Pavia) 2011; 1:e16. [PMID: 21808678 PMCID: PMC3143985 DOI: 10.4081/or.2009.e16] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2009] [Revised: 06/26/2009] [Accepted: 06/26/2009] [Indexed: 11/28/2022] Open
Abstract
The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc and 166 Ringloc) on 281 patients in the study. Revisions of prosthesis components were recorded and pelvic osteolytic lesions were assessed using radiographs and computed tomography. The linear head penetration rate was measured using the Martell method. The 10-year survival rate of the liner with revision due to liner wear and/or osteolysis as endpoint was 88% for the Hexloc liner and 98% for the Ringloc liner. The 15-year survival rate of the Hexloc liner was 67%. Pelvic osteolysis was found in 27% of the Hexloc and 19% of the Ringloc hips. After 15 years, 53% of the Hexloc hips had developed an osteolytic lesion. The linear head penetration rate was 0.16 mm/year for the Hexloc liner and 0.12 mm/year for the Ringloc liner. This paper is the first to describe the rapidly deteriorating survival up to 15 years with the old generation gamma-in-air sterilized polyethylene used in Hexloc liners. The newer Ringloc liner with the ArCom™ polyethylene has superior clinical results but a linear wear rate and frequency of osteolytic lesions that is higher than expected.
Collapse
Affiliation(s)
- Sköldenberg Olof
- Karolinska Institutet, Department of Clinical Sciences at Danderyd Hospital, Stockholm, Sweden
| | | | | | | | | | | |
Collapse
|
49
|
Abstract
The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.
Collapse
Affiliation(s)
- Theodore T Miller
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States.
| |
Collapse
|
50
|
Abstract
BACKGROUND Little is known about intraarticular pathology following THA prior to the radiographic appearance of osteolysis, primarily due to imaging limitations. MRI has recently been applied to imaging the postarthroplasty hip with the ability to detect periarticular bony and soft tissue pathology; specifically, it is able to detect abnormal synovial patterns and focal bone loss well before the radiographic appearance of osteolysis. QUESTIONS/PURPOSES We therefore used MRI to determine the incidence of early reactive synovitis and osteolysis in asymptomatic patients after THA, and whether there is an association between these MRI findings and clinical outcomes or radiographic wear measurements at this early stage. METHODS We recruited 31 patients (33 hips) who underwent routine noncemented THA with one of three types of bearing surfaces: metal-on-cross-linked polyethylene (n = 7), ceramic-on-ceramic (n = 12), and ceramic-on-cross-linked polyethylene (n = 14). Patients underwent specialized MRI at a minimum of 12 months (mean, 23 months; range, 12-37 months) after surgery. MR images were analyzed for the presence of synovitis or osteolysis. WOMAC scores, patient assessment questionnaires, and radiographic wear measurements were correlated with MRI findings. RESULTS Reactive synovitis was observed in 13 of 33 patients (39%) and focal osteolysis in one of 33 (3%). The presence of synovitis did not correlate with pain, activity level, patient satisfaction or clinical outcome scales, nor did it correlate with radiographic wear measurements at early followup. CONCLUSIONS Our observations suggest reactive synovitis is common yet asymptomatic at short-term followup. We do not know either the etiology or the long-term implications of these observations.
Collapse
|