1
|
Tamagawa S, Nojiri H, Sato T, Matsukawa T, Homma Y, Takano H, Ishijima M. Comparison of blood metal ion levels in scoliosis patients following instrumented spinal fusion with cobalt-chromium and titanium alloy rods. Sci Rep 2025; 15:16549. [PMID: 40360646 PMCID: PMC12075639 DOI: 10.1038/s41598-025-99065-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Accepted: 04/15/2025] [Indexed: 05/15/2025] Open
Abstract
Elevated blood metal ion levels have been reported in patients following instrumented spinal fusion. However, the relationship between blood metal ion levels and clinical and radiographic outcomes remains elusive. The purpose of this study was to compare blood metal ion levels in patients with scoliosis undergoing corrective fusion surgery utilizing either cobalt-chromium (CoCr) or titanium (Ti) alloy rods, as well as preoperative scoliosis patients. Additionally, we investigated patient- and surgery-related factors associated with blood metal ion levels. This retrospective cohort study included 59 patients with CoCr rods (CoCr group), 29 patients with Ti alloy rods (Ti group), and 17 preoperative patients (control group). Blood samples were collected at a mean of 63 months postoperatively for the CoCr group and 113 months postoperatively for the Ti group. Blood levels of Co, Cr, and Ti were measured by inductively coupled plasma mass spectrometry. Blood Co levels were significantly elevated in the CoCr group compared to the control group (p = 0.021), with no significant difference observed between the CoCr and Ti groups (CoCr group: 0.28 μg/L, Ti group: 0.21 μg/L, control group: 0.20 μg/L). However, blood Cr and Ti levels were found to be below the limit of quantification in all 105 individuals. Furthermore, a significant negative correlation was observed between blood Co levels and the postoperative follow-up duration. These findings underscore the medium-term safety rather than the concerns regarding blood metal ion levels following corrective fusion for scoliosis; however, prolonged and meticulous follow-up is imperative.
Collapse
Affiliation(s)
- Shota Tamagawa
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Hidetoshi Nojiri
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan.
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan.
| | - Tatsuya Sato
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan
| | - Takehisa Matsukawa
- Department of Epidemiology and Environmental Health, Juntendo University Faculty of Medicine, Tokyo, Japan
- Department of Forensic Medicine, Juntendo University Faculty of Medicine, Tokyo, Japan
- Laboratory of Hygienic Chemistry, Juntendo University Faculty of Pharmacy, Chiba, Japan
| | - Yasuhiro Homma
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Hiromitsu Takano
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Muneaki Ishijima
- Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
2
|
Lizcano JD, Marei S, Sharkey PF, Higuera-Rueda CA, Moskal JT, Clyburn TA, Suleiman LI, McGrory BJ. Does the Type of Femoral Stem and/or Femoral Head Influence the Rate of Adverse Local Tissue Reactions After Primary Total Hip Arthroplasty? J Arthroplasty 2025; 40:S121-S124. [PMID: 39426440 DOI: 10.1016/j.arth.2024.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 10/08/2024] [Accepted: 10/11/2024] [Indexed: 10/21/2024] Open
Affiliation(s)
- Juan D Lizcano
- Department of Orthopaedics Cleveland Clinic, Weston, Florida
| | - Sameh Marei
- Menoufia Orthopedic Surgery Department, Menoufia University Hospitals, Menoufia, Egypt
| | | | | | - Joseph T Moskal
- Department of Orthopaedics Carilion Clinic, Roanoke, Virginia
| | - Terry A Clyburn
- Department of Orthopaedics Houston Methodists, Houston, Texas
| | - Linda I Suleiman
- Department of Orthopaedics Northwestern Feinberg School of Medicine, Chicago, Illinois
| | - Brian J McGrory
- Department of Orthopaedics Tufts University School of Medicine, Boston, Massachusetts
| |
Collapse
|
3
|
Zhong Q, Pan X, Chen Y, Lian Q, Gao J, Xu Y, Wang J, Shi Z, Cheng H. Prosthetic Metals: Release, Metabolism and Toxicity. Int J Nanomedicine 2024; 19:5245-5267. [PMID: 38855732 PMCID: PMC11162637 DOI: 10.2147/ijn.s459255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 05/13/2024] [Indexed: 06/11/2024] Open
Abstract
The development of metallic joint prostheses has been ongoing for more than a century alongside advancements in hip and knee arthroplasty. Among the materials utilized, the Cobalt-Chromium-Molybdenum (Co-Cr-Mo) and Titanium-Aluminum-Vanadium (Ti-Al-V) alloys are predominant in joint prosthesis construction, predominantly due to their commendable biocompatibility, mechanical strength, and corrosion resistance. Nonetheless, over time, the physical wear, electrochemical corrosion, and inflammation induced by these alloys that occur post-implantation can cause the release of various metallic components. The released metals can then flow and metabolize in vivo, subsequently causing potential local or systemic harm. This review first details joint prosthesis development and acknowledges the release of prosthetic metals. Second, we outline the metallic concentration, biodistribution, and elimination pathways of the released prosthetic metals. Lastly, we discuss the possible organ, cellular, critical biomolecules, and significant signaling pathway toxicities and adverse effects that arise from exposure to these metals.
Collapse
Affiliation(s)
- Qiang Zhong
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Xin Pan
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yuhang Chen
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Qiang Lian
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Gao
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yixin Xu
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Wang
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Zhanjun Shi
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Hao Cheng
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| |
Collapse
|
4
|
Engh CA, Bhal V, Hopper RH. Metal levels and glomerular filtration rate after unilateral Birmingham Hip Resurfacing. Bone Joint J 2024; 106-B:44-50. [PMID: 38423104 DOI: 10.1302/0301-620x.106b3.bjj-2023-0849.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years.
Collapse
Affiliation(s)
- Charles A Engh
- Anderson Orthopedic Clinic & Inova Mount Vernon Joint Replacement Center, Alexandria, Virginia, USA
| | - Vinay Bhal
- Edwards Lifesciences, Irvine, California, USA
| | - Robert H Hopper
- Anderson Orthopaedic Research Institute, Alexandria, Virginia, USA
| |
Collapse
|
5
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:26-34. [PMID: 37270057 DOI: 10.1016/j.recot.2023.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/23/2023] [Accepted: 05/29/2023] [Indexed: 06/05/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, España.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, España; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, España
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| |
Collapse
|
6
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. [Translated article] Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:T26-T34. [PMID: 37992863 DOI: 10.1016/j.recot.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 05/29/2023] [Indexed: 11/24/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyse their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the H MAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), p=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilisation of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), p=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, Spain.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, Spain; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| |
Collapse
|
7
|
Davis TP. Metal-on-Metal Hip Arthroplasty: A Comprehensive Review of the Current Literature. Cureus 2023; 15:e48238. [PMID: 37929272 PMCID: PMC10624517 DOI: 10.7759/cureus.48238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2023] [Indexed: 11/07/2023] Open
Abstract
Metal-on-metal (MoM) total hip arthroplasty has been widely used since the end of the 20th century, although rates have now decreased due to concerns regarding adverse reactions and failure rates. The MoM implant has been replaced with other materials, such as ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP). This literature review looks at the past and present use of MoM prostheses to assess whether the turn away from MoM use is justified. Online literature searches were performed on PubMed, Ovid Medical Literature Analysis and Retrieval System Online (MEDLINE), and Web of Science online databases using the search terms "MoM and (ARMD and ALVAL)" (ARMD: adverse reaction to metal debris; ALVAL: aseptic lymphocyte-dominant vasculitis-associated lesion). A total of 64 relevant titles were included in the review. Although risk factors for adverse reactions and the causes of ARMD are generally agreed upon, more work is required to further understand the specific thresholds of blood metal ion levels that can be used to consistently identify ARMD and excessive metal wear-debris in patients who have not had their MoM implants revised. Metal-on-metal devices are not an acceptable option for total hip arthroplasties (THAs) in their current formulation due to the high rate and risk of ARMD. Some MoM hip resurfacing operations are appropriate for very carefully selected patients who are fully aware of the risks posed by the implant. It is recommended that device-specific thresholds for metal ion levels be developed to identify patients at risk of ARMD locally and systemically while using auxiliary tools to assist diagnosis, such as metal artefact reduction sequences (MARS)-MRI and hip scoring tools. Further work should investigate device-specific blood metal ion levels, the systemic effects of raised metal ion concentrations secondary to MoM arthroprosthetic wear, and the potential risks of ARMD caused by wear from tapered stems (including the implications this has for patients with CoC and MoP prostheses).
Collapse
Affiliation(s)
- Timothy P Davis
- Department of Anatomy, University of Nottingham Medical School, Nottingham, GBR
| |
Collapse
|
8
|
Fortmann C, Göen T, Wiesner S, Hegermann J, Kiblawi R, Dohna M, Ure BM, Renz DM, Petersen C, Kuebler JF. Titanium nitride coating of pectus bar increases metal contamination after minimally-invasive repair of pectus excavatum. PLoS One 2023; 18:e0292616. [PMID: 37824548 PMCID: PMC10569521 DOI: 10.1371/journal.pone.0292616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 09/25/2023] [Indexed: 10/14/2023] Open
Abstract
INTRODUCTION Previous studies demonstrated a release of toxic metals, e.g. nickel and chromium, from stainless steel bars used for minimally invasive repair of pectus excavatum (MIRPE). In the present study, we investigated the impact of titanium nitride coating on the metal release and exposure of MIRPE patients. MATERIAL AND METHODS We analyzed the courses of nickel and chromium levels in blood, urine and local tissue in patients undergoing MIRPE with a titanium nitride coated pectus bar between 03/2017 and 10/2018. Sample collection was scheduled prior to MIRPE, at defined postoperative time points and at bar removal. Additionally, we evaluated irritative symptoms. Results were compared to a control group who received uncoated stainless steel bars in a previous time period (03/2015-02/2017). RESULTS 12 patients received coated pectus bars (mean age 15.7 years). The control group included 28 patients. After implantation of a titanium nitride coated bar, significant increase in systemic nickel and chromium levels after one, two and three years was noted. In an interim analysis one year after MIRPE, we observed patients with coated bars to have significantly elevated trace metal values compared to the control group. This elevation persisted throughout the observation period. Tissue metal values were also significantly increased. Irritative symptoms occurred significantly more often in study patients compared to controls (50.0% vs. 14.3%). CONCLUSIONS Coating of pectus bars with titanium nitride failed to reduce metal contamination after MIRPE. Instead, it resulted in a significant increase of trace metal levels after MIRPE, compared to patients with stainless steel bars, which may be explained by wear of the coating and inter-component mobilization processes.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Thomas Göen
- Social and Environmental Medicine, Institute and Outpatient Clinic of Occupational, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Soeren Wiesner
- Hannover Medical School, Institute for Biostatistics, Hannover, Germany
| | - Jan Hegermann
- Hannover Medical School, Research Core Unit Electron Microscopy, Institute of Functional and Applied Anatomy, Hannover, Germany
| | - Rim Kiblawi
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Martha Dohna
- Department of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Diane Miriam Renz
- Department of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kuebler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
9
|
Migliorini F, Pilone M, Bell A, Merfort R, Giorgino R, Maffulli N. Serum cobalt and chromium concentration following total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:6918. [PMID: 37106086 PMCID: PMC10140036 DOI: 10.1038/s41598-023-34177-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/25/2023] [Indexed: 04/29/2023] Open
Abstract
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany.
| | - Marco Pilone
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany
| | - Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Riccardo Giorgino
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, ST4 7QB, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Queen Mary University of London, Mile End Hospital, E1 4DG, London, England
| |
Collapse
|
10
|
Zheng C, Xu J, Wu L, Wu Y, Liu Y, Shen B. Comparisons of Different Bearing Surfaces in Cementless Total Hip Arthroplasty: A Systematic Review and Bayesian Network Analysis. J Arthroplasty 2023; 38:600-609. [PMID: 36265721 DOI: 10.1016/j.arth.2022.10.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/06/2022] [Accepted: 10/11/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND We aimed to make comparisons of different bearing surfaces in patients after cementless total hip arthroplasty. METHODS The network meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guideline. The primary outcomes were implant survival and Harris hip score (HHS). Secondary outcomes included linear wear rates and serum level of metal ions. Subgroup analyses were performed by: (1) classifying head sizes as small and large; (2) femoral heads as ceramic and metal; and (3) liners as metal, ceramic, polyethylene, highly cross-linked polyethylene (HXP), or vitamin E-infused highly cross-linked polyethylene (HXPE). A total of 64 eligible RCTs with different bearings were assessed. Overall inconsistency and heterogeneity were acceptable. RESULTS In the 10 years follow-up, metal-on-polythene and ceramic-on-polythene bearings with small heads showed higher risk for revisions compared with metal-on-HXP and ceramic-on-HXP bearings with small heads. Similarly, only metal or ceramic-on-polythene bearings with small heads showed inferiority in HHS compared with other bearings. Conventional polyethylene liners showed higher linear wear rates compared with HXP, HXPE, and ceramic liners at 5 and 10 years after surgery, while metal-on-metal and ceramic-on-metal bearings showed higher serum level of cobalt and chromium. CONCLUSION Bearings containing HXP, HXPE, and ceramic liners showed comparable survivorship and hip function at follow-up of 5 and 10 years. Hard-on-hard bearings containing metal had higher serum level of metal ions than others. Bearings containing conventional polyethylene had worse performance in terms of implant survival, hip function, and wear rates. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Che Zheng
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Jiawen Xu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Liming Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuangang Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuan Liu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Bin Shen
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| |
Collapse
|
11
|
Lass R, Bechler U, Springer B, Rueckl K, Hanreich C, Boettner F. Midterm results of the Birmingham hip resurfacing: a single-surgeon series. Arch Orthop Trauma Surg 2023; 143:1041-1048. [PMID: 35076766 DOI: 10.1007/s00402-021-04305-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Birmingham hip resurfacing (BHR) is readily used as alternative to total hip replacement in younger patients. The current study aims to compare outcomes in terms of adverse local tissue reactions (ALTR), elevated metal ion levels and survival rates between low-risk (femoral component size ≥ 48 mm) and high-risk (femoral component size < 48 mm) BHR patients at a minimum 5-year follow-up (FU). MATERIALS AND METHODS We report the minimum 5-year, single surgeon outcome results of 183 BHRs, performed between 2007 and 2012. 154 patients, 18 women (20 hips) and 136 men (163 hips) were included in the study. Patients were grouped in 149 low-risk cases (femoral component size ≥ 48 mm) and in 34 high-risk cases (18 female/12 male) patients with a femoral head size < 48 mm). RESULTS At a minimum of 5-years FU time, 91% of the patients were available for FU. The overall survival rate was 91.8%. There were five revisions (survival rate 96.6%) in the low-risk group and ten revisions (survival rate 70.6%) in the high-risk group. In the low-risk group, six patients (6.5%) showed elevated metal ion levels (> 7 μg/l), compared to five patients (20.8%) in the high risk-group (p = 0.03). CONCLUSION Including the surgeon's initial learning curve, the BHR shows very good mid-term survival rates in the low-risk group but should, as previously demonstrated, not be considered for patients with less than 48 mm femoral head size. LEVEL OF EVIDENCE Level III: retrospective cohort study.
Collapse
Affiliation(s)
- Richard Lass
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics and Traumatology, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria
| | - Ulrich Bechler
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Bernhard Springer
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics and Traumatology, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria
| | - Kilian Rueckl
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Orthopedic Clinic König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Carola Hanreich
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
| | - Friedrich Boettner
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
12
|
Fortmann C, Goeen T, Zinne N, Wiesner S, Ure BM, Petersen C, Kuebler JF. Nickel contamination after minimally-invasive repair of pectus excavatum persists after bar removal. PLoS One 2022; 17:e0275567. [PMID: 36215223 PMCID: PMC9550087 DOI: 10.1371/journal.pone.0275567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 09/20/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Minimally-invasive repair of pectus excavatum (MIRPE) has been shown to be associated with high release of trace metals into patient's body. The aim of our study was to analyze the kinetics of metal contamination after MIRPE and after bar removal. METHODS We prospectively assessed nickel and chromium changes in blood, urine, and local tissue in patients undergoing MIRPE with stainless-steel bar(s). Baseline samples were taken prior to surgery, further samples were taken at six defined time points until 30 months after bar removal. Clinical symptoms were evaluated at the time of every sample collection. RESULTS 28 patients were included (mean age 16.4 years). At four weeks after MIRPE and persisting up to bar removal, we found significantly elevated trace metal levels in blood and urine. Tissue nickel and chromium levels were significantly elevated at the time of bar removal. After bar removal, the concentration of trace metal in urine and the concentration of chromium in plasma decreased gradually. In contrast, nickel levels in blood further increased. Five patients showed irritative symptoms after MIRPE, all symptomatic patients had elevated metal levels. CONCLUSIONS Following MIRPE, we found a rapid systemic increase of nickel and chromium. Our data indicate that trace metal release could cause irritative symptoms. The prolonged elevated systemic nickel levels beyond bar removal necessitate further investigations of the long-term side effects of MIRPE.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
- * E-mail:
| | - Thomas Goeen
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Norman Zinne
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Soeren Wiesner
- Institute for Biometry, Hannover Medical School, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kuebler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
13
|
Clinical Outcomes, Metal Ion Levels, Lymphocyte Profiles, and Implant Survival Following Five Different Bearings of Total Hip Arthroplasty: A Mean 10-year Follow-up Study. J Arthroplasty 2022; 37:2053-2062. [PMID: 35490981 DOI: 10.1016/j.arth.2022.04.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 04/15/2022] [Accepted: 04/22/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Different bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years. METHODS From January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry. RESULTS No difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups. CONCLUSIONS Metal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation. LEVEL OF EVIDENCE Therapeutic Level II.
Collapse
|
14
|
Analysis of serum levels of titanium and aluminium ions in patients with early onset scoliosis operated upon using the magnetic growing rod-a single centre study of 14 patients. Spine Deform 2021; 9:1473-1478. [PMID: 34297320 PMCID: PMC8363538 DOI: 10.1007/s43390-021-00335-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 03/15/2021] [Indexed: 10/24/2022]
Abstract
STUDY DESIGN A cross-sectional retrospective Level 3 study. OBJECTIVE To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system. 14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5-15 years). The average period of follow-up was 43.7 months (28-79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications. METHODS The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry. RESULTS For the sake of ease of assessment, patients were divided into three etiology-based groups-idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1-28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1-0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery. CONCLUSION Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.
Collapse
|
15
|
Reiner T, Klotz MC, Seelmann K, Hertzsch F, Innmann MM, Streit MR, Nees TA, Moradi B, Merle C, Kretzer JP, Gotterbarm T. Long-Term Results of a Second-Generation, Small-Diameter, Metal-On-Metal Bearing in Primary Total Hip Arthroplasty at 14-year Follow-Up. MATERIALS 2020; 13:ma13030557. [PMID: 31991553 PMCID: PMC7040657 DOI: 10.3390/ma13030557] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/13/2020] [Accepted: 01/20/2020] [Indexed: 12/12/2022]
Abstract
(1) Background: The objective of the present study was to review the clinical and radiological results of a small-head, MoM bearing in primary THA and to determine blood metal ion levels at long-term follow-up. (2) Methods: We retrospectively evaluated the clinical and radiological results of 284 small-diameter, MoM 28-mm Metasul THA at a mean follow-up of 14.5 years, and measured blood metal ion concentrations in 174 of these patients. (3) Results: After 14 years, survival free for revision due to any reason was 94%. Proximal femoral osteolysis was seen in 23% of hips, and MRI demonstrated ARMD in 27 of the 66 investigated hips (41%). Mean cobalt, chromium, and titanium ion concentrations were 0.82 µg/L (range 0.22-4.45), 1.51 µg/L (0.04-22.69), and 2.68 µg/L (0.26-19.56) in patients with unilateral THA, and 2.59 µg/L (0.43-24.75), 2.50 µg/L (0.26-16.75), and 3.76 µg/L (0.67-19.77), respectively in patients with bilateral THA. Twenty-nine percent of patients showed cobalt or chromium ion levels > 2 µg/L. (4) Conclusions: Despite good clinical long-term results, increased blood metal ion levels (cobalt or chromium > 2 µg/L) were found in approximately one-third of asymptomatic patients, and proximal femoral osteolysis and ARMD were frequently seen in this cohort. Blood metal ion analysis appears helpful in the long-term follow-up of these patients in order to identify individuals at risk. In accordance with contemporary consensus statements, symptomatic patients with elevated metal ion levels and/or progressive osteolysis should be considered for additional CT or MARS MRI to determine the extent of soft tissue affection prior to revision surgery. Further studies are necessary to investigate the clinical relevance of ARMD in asymptomatic patients with small-head, MoM THA.
Collapse
Affiliation(s)
- Tobias Reiner
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
- Correspondence: ; Tel.: +49-6221-5634803; Fax: +49-6221-5626360
| | - Matthias C. Klotz
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Kirsten Seelmann
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Fabian Hertzsch
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Moritz M. Innmann
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Marcus R. Streit
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Timo A. Nees
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Babak Moradi
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Christian Merle
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany;
| | - Tobias Gotterbarm
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
- Department of Orthopedics, Kepler University Hospital, Krankenhausstr. 7a, 4020 Linz, Austria
| |
Collapse
|
16
|
Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design? Clin Orthop Relat Res 2019; 477:2007-2014. [PMID: 30811355 PMCID: PMC7000071 DOI: 10.1097/corr.0000000000000638] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Elevated serum levels of chromium and cobalt ions in metal-on-metal (MoM) bearing surfaces is a well-known phenomenon in THA. However, few studies have addressed this issue in complex primary and revision knee arthroplasty using a MoM hinged mechanism, and no study, to our knowledge, has investigated knees with MoM hinges in patients without megaprostheses (tumor prostheses). QUESTIONS/PURPOSES We analyzed a series of patients who received MoM hinged revision knee prostheses and asked: (1) What are the serum metal ion levels at short-term followup? (2) Is there any correlation between metal ion levels and the Knee Society Score (KSS) at this followup? METHODS Between 2013 and 2017, we performed 198 revision knee arthroplasties, of which 32 (17.7%) were performed with a latest-generation MoM hinge knee design. In addition, three complex primary TKAs utilizing the same design were included in this study. The device features a metal-on-polyethylene bearing with a MoM hinge. During that period, our general indications for using a hinge were single-stage and two-stage revision surgeries, revisions with large bone defects, and primary TKA with > 20° mechanical malalignment or collateral ligament insufficiency. Of the 35 patients who received this device, 23 patients (65% of the overall group who received this implant; 11 males, 12 females) were available for followup at a median of 28 months (range, 13-61 months), and the remaining 12 (35%) patients were lost to followup. Our rationale for reporting before the more typical 2-year minimum was the finding of elevated serum ion levels with unclear clinical significance. Median age at the time of surgery was 68 years (range, 52-84 years). None of the patients included in the study had other implants with MoM bearings. Serum ion levels of chromium (III) and cobalt were assessed using mass spectrometry. Ion levels > 5 ppb were considered elevated. Clinical outcome was assessed using the original KSS. RESULTS Median chromium serum level was 6.3 ppb (range, 0.6-31.9 ppb) and median cobalt serum level was 10.5 (range, 1.0-47.5 ppb). Of the 23 patients, 16 had elevated serum ion levels. There was a moderate correlation between KSS and both chromium (p = 0.029, r = 0.445) and cobalt (p = 0.012, r = 0.502) levels. CONCLUSIONS Elevated metal ion levels and radiolucent lines are common after surgery with this MoM hinge design at short-term followup, and we believe this finding is of great concern. Although no patient has yet been revised, these patients will be closely monitored. We recommend that serum ion analysis become a routine part of followup after any hinge TKA in an attempt to better understand the potential consequences of this phenomenon. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
17
|
Kim CH, Ryu JJ, Jeong MY, Kim JW, Chang JS, Yoon PW. Serum Metal Ion Levels in Cementless Metal-On-Metal Total Hip Arthroplasty: Long-Term Follow-Up Trends. J Arthroplasty 2019; 34:534-537. [PMID: 30545656 DOI: 10.1016/j.arth.2018.11.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Revised: 09/30/2018] [Accepted: 11/14/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Long-term trends in serum metal ion concentration after metal-on-metal (MoM) total hip arthroplasty (THA) are unclear. In most studies, serum metal ion levels increase initially and remain constant during follow-up. However, there are no previous studies that evaluate the metal ion level longitudinally at multiple intervals over the long term. Increasing metal ion levels during the long-term follow-up of patients who underwent cementless MoM THA has been seen, so this study investigated those trends. METHODS Seventy-one patients were followed for a minimum of 10 years (range, 10.0-18.6 years). All underwent unilateral THA with MoM bearings. Serum cobalt (Co) and chromium (Cr) levels were measured preoperatively and annually after surgery. Trends and differences in serum levels based on sex, mean age, body mass index, cup inclination, and implant selection were analyzed. RESULTS Within 5 years after the operation, the mean Co and Cr levels peaked postoperatively at 3-4 years (4.14 and 6.89 μg/L, respectively). Between 5 and 10 years postoperatively, the serum levels showed 2 tendencies. One group (62) showed a constant range, but a smaller group (9) showed increasing serum metal ion levels. The only factor which showed a difference between the 2 groups was body mass index (P = .030), which was lower in the increasing serum metal ion level group. CONCLUSION At a medium-term to long-term follow-up period, serum Co and Cr levels are not always constant. This should be considered when seeing patients with MoM THA, and laboratory tests may be needed for long-term follow-up.
Collapse
Affiliation(s)
- Chul-Ho Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Jung Ryu
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Mi Yeon Jeong
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Ji Wan Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Suk Chang
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Pil Whan Yoon
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
18
|
Tashjian RZ, Chalmers PN. Future Frontiers in Shoulder Arthroplasty and the Management of Shoulder Osteoarthritis. Clin Sports Med 2018; 37:609-630. [DOI: 10.1016/j.csm.2018.05.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
19
|
Hunt LP, Blom AW, Matharu GS, Porter ML, Whitehouse MR. The risk of developing cancer following metal-on-metal hip replacement compared with non metal-on-metal hip bearings: Findings from a prospective national registry "The National Joint Registry of England, Wales, Northern Ireland and the Isle of Man". PLoS One 2018; 13:e0204356. [PMID: 30235326 PMCID: PMC6147563 DOI: 10.1371/journal.pone.0204356] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Accepted: 09/06/2018] [Indexed: 12/13/2022] Open
Abstract
Background and purpose Over 1 million metal-on-metal hip replacements were implanted. Even well-functioning implants produce wear debris that can cause tissue damage, disseminate and cause DNA damage. We aimed to establish if there was an association between metal-on-metal hip replacement and the risk of subsequently developing cancer compared with alternative hip replacements. Methods We performed a population based prospective longitudinal cohort study using data from the National Joint Registry linked to Hospital Episode Statistics (n = 403,881 patients). We examined the incidence of a new diagnosis of cancer in patients who received a metal-on-metal bearing in comparison with those who received a non metal-on-metal bearing. Kaplan-Meier estimates of time to first cancer diagnosis were used with Cox proportional hazards regression models to assess the effect on the time to cancer diagnosis for all cancer types, haematological, malignant melanoma, urinary tract cancers or prostate cancer in men. Results The maximum follow up available was 11.8 years with 25% of patients followed up for more than 6.8 years (mean follow up 4.6 years; median 4.3; IQR 2.1–6.8; range 0.01–11.8). Analyses by gender that adjusted for age at primary and presence or absence of linked Welsh (PEDW) records showed no increase in the risk of developing cancer according to the bearing surface implanted for all cancers, haematological cancers, malignant melanoma, urinary tract cancers or prostate cancer in men. For patients receiving a second hip replacement, there was also no difference. Conclusion We have demonstrated that there is currently no evidence of an increase in the risk of cancer following primary hip replacement according to the type of bearing material used. Although the risk of revision in metal-on-metal bearing hip replacements is higher, it is reassuring that the risk of a new diagnosis of cancer is not currently increased. Despite the long term follow up available in this study, the latency period for some cancers is very long and therefore continued monitoring is required to ensure no new patterns emerge that may indicate need for universal screening.
Collapse
Affiliation(s)
- Linda P. Hunt
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Ashley W. Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
| | - Gulraj S. Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Martyn L. Porter
- Centre for Hip Surgery, Wrightington Hospital, Wrightington, Lancashire, United Kingdom
- * E-mail: (MRW); (MLP)
| | - Michael R. Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
- * E-mail: (MRW); (MLP)
| |
Collapse
|
20
|
Shapiro JA, Eskildsen SM, Del Gaizo DJ. Systemic cobaltism manifesting as oral mucosal discoloration and metallic gustation after metal-on-metal hip resurfacing. Arthroplast Today 2018; 4:436-440. [PMID: 30560172 PMCID: PMC6287233 DOI: 10.1016/j.artd.2018.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 06/27/2018] [Accepted: 06/27/2018] [Indexed: 01/23/2023] Open
Abstract
Systemic cobaltism is a debilitating complication of metal-on-metal (MoM) arthroplasty. In this report, we review a case of a 54-year-old female with metallosis from a MoM hip resurfacing and varying degrees of black discoloration of her tongue and metallic gustation as a result of systemic cobaltism. After explanting the metal components, thorough debridement, and conversion to ceramic-on-polyethylene arthroplasty, the patient's oral mucosal discoloration and metallic gustation resolved. This represents the first documentation of systemic cobaltism from MoM hip resurfacing manifesting as oral mucosal discoloration and metallic gustation with resolution after explant, debridement, and conversion to ceramic-on-polyethylene total hip arthroplasty.
Collapse
Affiliation(s)
- Joshua A Shapiro
- Department of Orthopaedic Surgery, University of North Carolina, Chapel Hill, NC, USA
| | - Scott M Eskildsen
- Department of Orthopaedic Surgery, University of North Carolina, Chapel Hill, NC, USA
| | - Daniel J Del Gaizo
- Department of Orthopaedic Surgery, University of North Carolina, Chapel Hill, NC, USA
| |
Collapse
|
21
|
Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty. Ir J Med Sci 2018; 188:149-153. [PMID: 29732504 DOI: 10.1007/s11845-018-1808-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Accepted: 04/04/2018] [Indexed: 12/12/2022]
Abstract
BACKGROUND Failure to restore femoral offset in metal on polyethylene total hip arthroplasty (THA) causes polyethylene wear and aseptic loosening. To our knowledge, no study to date has investigated the relationship between femoral offset and wear in metal-on-metal (MOM) THA. AIMS In this study, we investigated the relationship between femoral offset and wear by measuring circulating metal ion levels in MOM THA. METHODS In this retrospective study, we identified patients who had undergone MOM THA with the ASR XL system (DePuy International Ltd., Leeds, UK). Femoral offset was measured using anteroposterior radiographs, and circulating metal ion levels (cobalt and chromium) were recorded. RESULTS In total, 95 patients were included (68 males and 27 females). The mean age at the time of surgery was 64.9. Mean time from surgery to blood sampling was 15.4 months. No statistically significant relationship was found between femoral offset and cobalt (p = 0.313) or chromium (p = 0.401) ions. CONCLUSION It is known that failure to restore femoral offset during THA can lead to high rates of wear in metal-on-polyethylene articulations. In our study, no statistically significant relationship was found between femoral offset and serum cobalt or chromium ions. This study adds to the information available to surgeons regarding factors that increase wear in metal-on-metal total hip arthroplasty.
Collapse
|
22
|
Tetreault MW, Jacobs JJ, Mahmud W, Nam D. Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels. Orthopedics 2018; 41:e438-e441. [PMID: 29257191 DOI: 10.3928/01477447-20171213-05] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Accepted: 10/17/2017] [Indexed: 02/03/2023]
Abstract
In the 1990s, metal-on-metal (MoM) bearings were reintroduced in total hip arthroplasty (THA), having the proposed advantages of decreased wear and improved stability. However, catastrophic adverse local tissue reaction (ALTR) secondary to metal debris from both the bearing surface and the head-neck junction is a well-recognized complication. The measurement of metal ion levels in the serum is often a first-line test to identify failure of a MoM bearing. The authors describe a 70-year-old man who presented with a multiply revised MoM THA and a large periprosthetic fluid collection incidentally seen during computed tomography for renal nephrolithiasis. The patient reported painless, progressive swelling over the lateral aspect of the hip. An infectious workup including serum erythrocyte sedimentation rate, C-reactive protein, and intraarticular hip aspiration yielded negative results. Metal ion levels in the serum, including a minimally elevated cobalt level, were unremarkable, and metal-lymphocyte transformation testing yielded negative results. Radiographic imaging revealed progressive osteolysis around the proximal femur, and magnetic resonance imaging showed large fluid collections with irregular wall thickening surrounding the gluteal and iliopsoas musculature. At revision surgery, a large fluid collection and corrosion at the head-neck junction were present. Pathology specimens confirmed the presence of an ALTR. This report presents a previously undescribed case of an ALTR secondary to MoM THA in the absence of elevated serum metal ion levels. This indicates the necessity of considering all aspects of a patient's clinical presentation, imaging modalities, and laboratory testing in the evaluation and diagnosis of a symptomatic MoM THA. [Orthopedics. 2018; 41(3):e438-e441.].
Collapse
|
23
|
Matharu GS, Judge A, Eskelinen A, Murray DW, Pandit HG. What is appropriate surveillance for metal-on-metal hip arthroplasty patients? Acta Orthop 2018; 89:29-39. [PMID: 29105547 PMCID: PMC5810829 DOI: 10.1080/17453674.2017.1398011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory authorities recommending regular surveillance, even for asymptomatic individuals. However, these recommendations are not evidence-based and are very costly. The rapidly evolving evidence base requires an update regarding the investigation and management of MoMHA patients. This article is the first of 2 (the second article in this series will consider the threshold for performing revision, and the outcomes following ARMD revision surgery: Matharu et al., Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update. Acta Orthop 2018; in press), and considers the various investigative modalities used during surveillance, with specific focus on blood metal ion sampling and cross-sectional imaging. No single investigation can universally be used during MoMHA patient surveillance. Recent studies have now provided important information on interpreting blood metal ions (effective in identifying patients at low risk of problems), clarifying the roles of cross-sectional imaging (reserve combined ultrasound and MARS-MRI for complex cases), and providing parameters to safely exclude many asymptomatic patients from regular surveillance. This information will be useful when designing future surveillance protocols for MoMHA patients.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK;,Correspondence:
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | | | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| |
Collapse
|
24
|
Yilgor C, Efendiyev A, Akbiyik F, Demirkiran G, Senkoylu A, Alanay A, Yazici M. Metal Ion Release During Growth-Friendly Instrumentation for Early-Onset Scoliosis: A Preliminary Study. Spine Deform 2018; 6:48-53. [PMID: 29287817 DOI: 10.1016/j.jspd.2017.06.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 05/01/2017] [Accepted: 06/18/2017] [Indexed: 11/16/2022]
Abstract
BACKGROUND Metal ions released from spinal instruments can cause localized debris and distribute systemically to settle on distant organs. Children with early-onset deformities live with metallic implants for a substantial amount of time. No research focused on metal distribution in growth-friendly instrumentations. The aim of this study was to compare age-matched growing rod (GR) and magnetically controlled growing rod (MCGR) groups to noninstrumented controls. METHODS The study was designed as a multicenter, prospective, cross-sectional case series. GR and MCGR applications of three institutions were included. A total of 52 children were enrolled. Blood samples were collected between December 2014 and February 2015. Biochemical serum analyses were performed to trace and quantify titanium, vanadium, aluminum, and boron. The GR group included 15 children. Mean age was 10.7 (range 6-15). MCGR group included 22 children. Mean age was 8.5 (range 2-13). Fifteen age-matched nonoperated children formed the control group. The mean age was 10.4 (range 5-15). One-way analysis of variance, Kruskal-Wallis, and Mann-Whitney U tests were used for comparisons. RESULTS The mean serum titanium level in control, GR, and MCGR groups were 2.8 ± 1.4, 7.3 ± 4.3, and 10.2 ± 6.8 μg/L, respectively. GR and MCGR group titanium levels were higher than controls' (p = .008 and p < .001). The mean serum vanadium level in control, GR, and MCGR groups were 0.2 ± 0.0, 0.2 ± 0.0, and 0.5 ± 0.5 μg/L, respectively. MCGR group vanadium level was higher than control (p < .001) and GR groups (p = .004). Mean serum levels in control, GR, and MCGR groups were, respectively, 5.4 ± 4.1, 8.1 ± 7.4, and 7.8 ± 5.1 μg/L for aluminum and 86.7 ± 2.7, 86.9 ± 2.5, and 85.0 ± 6.6 μg/L for boron. The distribution of aluminum and boron were similar across groups (p = .675 and p = .396). CONCLUSIONS Both GR and MCGR applications significantly release titanium and possibly aluminum. MCGR further releases vanadium. MCGR possibly releases more titanium than traditional GR. Time-dependent alterations of serum ion levels, structural properties of the MCGR device, and exposure caused by magnetic distraction processes warrant investigation.
Collapse
Affiliation(s)
- Caglar Yilgor
- Orthopedics and Traumatology, Acibadem Mehmet Ali Aydınlar University, İçerenköy Mh. No:32 Kerem Aydınlar Kampüsü, Kayışdağı Cd., 34752 Ataşehir, Turkey
| | - Ayaz Efendiyev
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Filiz Akbiyik
- Medical Biochemistry, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Gokhan Demirkiran
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Alpaslan Senkoylu
- Orthopedics and Traumatology, Gazi University, Emniyet Mahallesi, 06560 Yenimahalle, Ankara, Turkey
| | - Ahmet Alanay
- Orthopedics and Traumatology, Acibadem Mehmet Ali Aydınlar University, İçerenköy Mh. No:32 Kerem Aydınlar Kampüsü, Kayışdağı Cd., 34752 Ataşehir, Turkey
| | - Muharrem Yazici
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey.
| |
Collapse
|
25
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
26
|
Fortmann C, Göen T, Krüger M, Ure BM, Petersen C, Kübler JF. Trace metal release after minimally-invasive repair of pectus excavatum. PLoS One 2017; 12:e0186323. [PMID: 29023602 PMCID: PMC5638555 DOI: 10.1371/journal.pone.0186323] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Accepted: 09/18/2017] [Indexed: 11/18/2022] Open
Abstract
Background Several studies have shown a high incidence of metal allergy after minimally-invasive repair of pectus excavatum (MIRPE). We postulated that MIRPE is associated with a significant release of trace metal ions, possibly causing the allergic symptoms. Methods We evaluated the concentration with chromium, cobalt and nickel in blood, urine and tissue in patients prior to MIRPE and in patients who underwent an explantation of the stainless-steel bar(s) after three years. Results Our study group consisted of 20 patients (mean age 19 years) who had bar explantation and our control group included 20 patients (mean age 16 years) prior to MIRPE. At the time of bar removal we detected significantly elevated concentrations of chromium and nickel in the tissue compared to patients prior to the procedure (p<0,001). We also found a significant increase in the levels of chromium in urine and nickel in blood in patients three years post MIRPE (p<0,001). Four patients temporarily developed symptoms of metal allergy, all had elevated metal values in blood and urine at explantation. Conclusions Minimally-invasive repair of pectus excavatum can lead to a significant trace metal exposure.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
- * E-mail:
| | - Thomas Göen
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | - Marcus Krüger
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kübler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
27
|
Carlson BC, Bryan AJ, Carrillo-Villamizar NT, Sierra RJ. The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2017; 32:S214-S219. [PMID: 28320566 DOI: 10.1016/j.arth.2017.02.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/03/2017] [Accepted: 02/11/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There is a paucity of data examining metal ion levels over time. METHODS We retrospectively reviewed 59 patients (69 hips) with an articular surface replacement total hip arthroplasty. We reviewed prerevision cobalt and chromium concentrations over time. RESULTS Seventy-one percent of patients who were revised and had multiple ion measurements (12/17) demonstrated increasing cobalt ion levels or elevated ion levels over time. There was a trend toward an elevated risk of revision for increasing cobalt and chromium levels starting at 12 and 4 ppb, respectively; this was significant for chromium levels above 7 ppb (hazard ratio 22.35, P = .001). Similarly, there was a trend toward an elevated risk of pseudotumor formation for increasing cobalt and chromium levels starting at 5 and 2.5 ppb, respectively; this was significant for cobalt levels above 7 ppb (hazard ratio 6.88, P = .027). CONCLUSION In this paper, cobalt and chromium levels levels above 5 and 2.5 ppb started to demonstrate an increased risk of ARMD, and should be considered as a lower cutoff for discussion with patients about the potential for future revision.
Collapse
Affiliation(s)
- Bayard C Carlson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Andrew J Bryan
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
28
|
Galea VP, Laaksonen I, Matuszak SJ, Connelly JW, Muratoglu O, Malchau H. Mid-term changes in blood metal ion levels after Articular Surface Replacement arthroplasty of the hip. Bone Joint J 2017; 99-B:33-40. [PMID: 28363892 DOI: 10.1302/0301-620x.99b4.bjj-2016-1250.r1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 01/04/2017] [Indexed: 11/05/2022]
Abstract
AIMS Our first aim was to determine whether there are significant changes in the level of metal ions in the blood at mid-term follow-up, in patients with an Articular Surface Replacement (ASR) arthroplasty. Secondly, we sought to identify risk factors for any increases. PATIENTS AND METHODS The study involved 435 patients who underwent unilateral, metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). These patients all had one measurement of the level of metal ions in the blood before seven years had passed post-operatively (early evaluation) and one after seven years had passed post-operatively (mid-term evaluation). Changes in ion levels were tested using a Wilcoxon signed-rank test. We identified subgroups at the highest risk of increase using a multivariable linear logistic regression model. RESULTS There were significant increases in the levels of metal ions for patients who underwent both MoM HRA (Chromium (Cr): 0.5 parts per billion (ppb); Cobalt (Co): 1.1 ppb) and MoM THA (Cr: 0.5 ppb; Co: 0.7 ppb). In a multivariable model considering MoM HRAs, the change in the levels of metal ions was influenced by female gender (Co: Odds Ratio (OR) 1.42; p = 0.002 and Cr: OR 1.08; p = 0.006). The change was found to be irrespective of the initial level for the MoM HRAs, whereas there was a negative relationship between the initial level and the change in the level for those with a MoM THA (Co: OR -0.43; p < 0.001 and Cr: OR -0.14; p = 0.033). CONCLUSION The levels of metal ions in the blood increase significantly over the period until mid-term follow-up in patients with both a MoM HRA and those with a MoM THA. We recommend that the levels of metal ions be measured most frequently for women with a MoM HRA. While those with a MoM THA appear to stabilise at a certain level, the accuracy of this trend is not yet clear. Vigilant follow-up is still recommended. Cite this article: Bone Joint J 2017;99-B(4 Supple B):33-40.
Collapse
Affiliation(s)
- V P Galea
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - I Laaksonen
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| | - S J Matuszak
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - J W Connelly
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - O Muratoglu
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| | - H Malchau
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| |
Collapse
|
29
|
The Role of Metal-on-Metal Bearings in Total Hip Arthroplasty and Hip Resurfacing: Review Article. HSS J 2017; 13:2-6. [PMID: 28167866 PMCID: PMC5264575 DOI: 10.1007/s11420-016-9521-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 07/20/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND The current role of metal-on-metal (MoM) bearings in hip arthroplasty remains controversial. The low wear offered by MoM bearings compared to metal-on-polyethylene and the possibility of a lower risk of dislocation with larger head sizes, encouraged a trend towards the re-introduction of the MoM bearing couple. However, recent evidence has shown that not all designs of the MoM bearing have been successful. QUESTIONS/PURPOSES The purpose of this paper is to provide an update on the use of MoM bearings and address the following issues: (1) the reintroduction of metal-on-metal bearings in total hip arthroplasty, (2) the failure of metal-on-metal bearings in stemmed total hip arthroplasty, (3) the role of metal-on-metal hip resurfacing in modern orthopaedics and (4) metal-on-metal hip resurfacing versus total hip arthroplasty. METHODS A literature search strategy was conducted using various search terms in MEDLINE and Embase. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'metal-on-metal', 'total hip arthroplasty' and 'hip resurfacing'. RESULTS The initial search retrieved 1240 articles. Twenty-two articles were selected and used in the review. CONCLUSION Metal-on-metal hip resurfacing is still a suitable treatment option in specific patient populations with the appropriate implant design and surgical skill, while stemmed metal-on-metal total hip arthroplasty should be avoided in all patient populations. Continued follow-up of patients undergoing metal-on-metal hip resurfacing is critical in order to further understand the long-term outcomes of these patients and why certain complications tend to occur with this procedure.
Collapse
|
30
|
Nakano N, Volpin A, Bartlett J, Khanduja V. Management Guidelines for Metal-on-metal Hip Resurfacing Arthroplasty: A Strategy on Followup. Indian J Orthop 2017; 51:414-420. [PMID: 28790470 PMCID: PMC5525522 DOI: 10.4103/ortho.ijortho_230_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Despite the initial promise of metal-on-metal (MoM) implants as the ideal bearing surface for hip replacements and resurfacings, high short term failure rates due to an adverse reaction to metal debris (ARMD) have led to a dramatic reduction in the number of MoM implants used in the modern era. With over one million patients worldwide having undergone hip operations utilizing a MoM bearing surface, the long term outcomes for such patients remains unknown, and there is much debate as to the most effective management of these patients. Although several regulatory bodies have released guidelines on the management of patients with MoM hips, these recommendations remain open to interpretation, and the most effective management for these patients remains unclear. The aim of this review is to compare the current guidelines for managing patients with MoM hips and also to discuss established ARMD risk factors, evidence regarding the optimum management for patients with MoM hips, and the indications for revision surgery. Furthermore, although specialized laboratory tests and imaging can be used to facilitate clinical decision making, over-reliance on any single tool should be avoided in the decision making process, and surgeons should carefully consider all findings when determining the most appropriate course of action.
Collapse
Affiliation(s)
- Naoki Nakano
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Andrea Volpin
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Jonathan Bartlett
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Vikas Khanduja
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK,Address for correspondence: Mr. Vikas Khanduja, Consultant Orthopaedic Surgeon and Elective Clinical Trials Research Lead, Department of Trauma and Orthopaedics, Cambridge University Hospitals NHS Foundation Trust, Box 37, Hills Road, Cambridge, CB2 0QQ, UK. E-mail:
| |
Collapse
|
31
|
Amanatullah DF, Sucher MG, Bonadurer GF, Pereira GC, Taunton MJ. Metal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis. Orthopedics 2016; 39:371-379. [PMID: 27459144 DOI: 10.3928/01477447-20160719-06] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 06/13/2016] [Indexed: 02/03/2023]
Abstract
Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articulations. Additionally, the article reviews mechanisms of metal wear, the biologic reaction to cobalt and chromium ions, the clinical presentation of failing metal-on-metal articulations, and current diagnostic strategies. Further, the article discusses the use of inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, and ultrasound for failed metal-on-metal THA procedures. When adopting new technologies, orthopedic surgeons must weigh the potential increased benefits against the possibility of new mechanisms of failure. Metal-on-metal bearings are a prime example of the give and take between innovation and clinical results, especially in the setting of an already successful procedure such as THA. [Orthopedics. 2016; 39(6):371-379.].
Collapse
|
32
|
Liow MHL, Kwon YM. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. INTERNATIONAL ORTHOPAEDICS 2016; 41:885-892. [PMID: 27761629 DOI: 10.1007/s00264-016-3305-1] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 09/25/2016] [Indexed: 12/12/2022]
Abstract
The potential advantages of contemporary MoM THA implants include less volumetric wear with subsequent reduction of polyethylene wear-induced osteolysis and greater component stability with use of large-diameter femoral heads. However, there have been concerns regarding significantly elevated revision rates in MoM THA due to MoM-related complications such as adverse local tissue reaction (pseudotumour) formation. The increased failure rate in MoM hip arthroplasty is associated with the generation of biologically active, nanometer sized metal particles from the MoM bearing surfaces and taper junctions, which result in the development of a localized, adverse periprosthetic soft tissue response. The focus of this article is to provide an update on (1) implant, surgical and patient factors associated with adverse local tissue reactions (pseudotumours) and (2) the clinical systematic evaluation and management of patients with MoM hip arthroplasty based on the currently available evidence. There should be a low threshold to conduct a systematic clinical evaluation of patients with MoM hip arthroplasty as early recognition and diagnosis will allow the initiation of prompt and appropriate treatment. As a symptomatic MoM total hip arthroplasty may have intrinsic and extrinsic causes, patients should be evaluated systematically, utilizing risk stratification algorithms. Although specialized laboratory tests such as metal ion levels and cross sectional imaging modalities such as MARS MRI can be used to facilitate clinical decision making, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Further research is required to obtain a better understanding of implant and patient risk factors associated with tribocorrosion in MoM total hip arthroplasty.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
33
|
Pijls BG, Meessen JMTA, Schoones JW, Fiocco M, van der Heide HJL, Sedrakyan A, Nelissen RGHH. Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis. PLoS One 2016; 11:e0156051. [PMID: 27295038 PMCID: PMC4905643 DOI: 10.1371/journal.pone.0156051] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Accepted: 05/09/2016] [Indexed: 11/19/2022] Open
Abstract
IMPORTANCE There are concerns about increased mortality in patients with metal-on-metal bearings in total hip arthroplasty (THA). OBJECTIVE To determine the mortality and the morbidity in patients with metal-on-metal articulations (MOM THA) compared to patients with non-metal-on-metal articulations (non-MOM THA) after primary total hip arthroplasty. DATA SOURCES Search of PubMed, MEDLINE, EMBASE, Web of Science, Cochrane, CINAHL, AcademicSearchPremier, ScienceDirect, Wiley and clinical trial registers through March 2015, augmented by a hand search of references from the included articles. No language restrictions were applied. STUDY SELECTION Two reviewers screened and identified randomised controlled trials and observational studies of primary total hip arthroplasty comparing MOM THA with non-MOM THA. DATA EXTRACTION AND SYNTHESIS Two reviewers independently extracted study data and assessed risk of bias. Risk differences (RD) were calculated with random effect models. Meta-regression was used to explore modifying factors. MAIN OUTCOMES AND MEASURES Difference in mortality and difference in morbidity expressed as revisions and medical complications between patients with MOM THA and non-MOM THA. RESULTS Forty-seven studies were included, comprising 4,000 THA in randomised trials and over 500,000 THA in observational studies. For mortality, random effects analysis revealed a higher pooled RD of 0.7%, 95%, confidence interval (CI) [0.0%, 2.3%], I-square 42%; the heterogeneity was explained by differences in follow-up. When restricted to studies with long term follow-up (i.e. 10 years or more), the RD for mortality was 8.5%, 95%, CI [5.8%, 11.2%]; number needed to treat was 12. Further subgroup analyses and meta-regression random effects models revealed no evidence for other moderator variables (study level covariates, e.g. resurfacing vs. non-resurfacing MOM) than follow-up duration. The quality of the evidence presented in this meta-analysis was characterized as moderate according to the CLEAR-NPT (for non-pharmacological trials) and Cochrane risk of bias Table. CONCLUSIONS AND RELEVANCE Meta-analysis suggests there may be an increased long-term risk of mortality and revision surgery for patients with MOM THA compared to patients with non-MOM THA. REGISTRATION PROSPERO 2014:CRD42014007417.
Collapse
Affiliation(s)
- B. G. Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - J. M. T. A. Meessen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - J. W. Schoones
- Walaeus Library, Leiden University Medical Centre, Leiden, The Netherlands
| | - M. Fiocco
- Department of Medical Statistics, Leiden University Medical Center, Leiden, The Netherlands
- Mathematical Institute, Leiden University, Leiden, The Netherlands
| | | | - A. Sedrakyan
- FDA Medical Device Epidemiology (MDEpiNet) Science and Infrastructure Center, U.S. Food and Drug Administration, Silver Spring, MD, United States of America
- Department of Healthcare Policy and Research, Weill Cornell Medical College, New York, NY, United States of America
| | - R. G. H. H. Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
34
|
Langton DJ, Sidaginamale RP, Avery P, Waller S, Tank G, Lord J, Joyce T, Cooke N, Logishetty R, Nargol AVF. Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a national retrieval centre. BMJ Open 2016; 6:e007847. [PMID: 27130159 PMCID: PMC4853972 DOI: 10.1136/bmjopen-2015-007847] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVES To determine risk factors for revision in patients implanted with a commonly used metal on metal (MoM) hip replacement. DESIGN Retrospective cohort study in combination with a prospective national retrieval study (Northern Retrieval Registry (NRR)). SETTING Combined orthopaedic unit in combination with the NRR. PARTICIPANTS All patients implanted with a DePuy Pinnacle MoM hip prostheses by the 2 senior authors were invited to attend for a review which included clinical examination, blood metal ion measurements, radiographs and targeted imaging. Explanted components underwent wear analysis using validated methodology and these results were compared with those obtained from the NRR. RESULTS 489 MoM Pinnacle hips were implanted into 434 patients (243 females and 191 males). Of these, 352 patients attended the MoM recall clinics. 64 patients had died during the study period. For the purposes of survival analysis, non-attendees were assumed to have well-functioning prostheses. The mean follow-up of the cohort as a whole was 89 months. 71 hips were revised. Prosthetic survival for the whole cohort was 83.6% (79.9-87.3) at 9 years. The majority of explanted devices exhibited signs of taper junction failure. Risk factors for revision were bilateral MoM prostheses, smaller Pinnacle liners, and implantation in 2006 and later years. A significant number of devices were found to be manufactured out of their specifications. This was confirmed with analysis of the wider data set from the NRR. CONCLUSIONS This device was found to have an unacceptably high revision rate. Bilateral prostheses, those implanted into female patients and devices implanted in later years were found to be at greater risk. A significant number of explanted components were found to be manufactured with bearing diameters outside of the manufacturer's stated tolerances. Our findings highlight the clinical importance of hitherto unrecognised variations in device production.
Collapse
Affiliation(s)
| | | | - Peter Avery
- Newcastle University, Newcastle upon Tyne, Newcastle, UK
| | - Sue Waller
- North Tees Nuffield Hospital, Stockton, UK
| | | | | | - Thomas Joyce
- Newcastle University, Newcastle upon Tyne, Newcastle, UK
| | - Nick Cooke
- University Hospital of North Tees, Stockton, UK
| | | | | |
Collapse
|
35
|
Chalmers BP, Perry KI, Taunton MJ, Mabry TM, Abdel MP. Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty. Curr Rev Musculoskelet Med 2016; 9:67-74. [PMID: 26816329 PMCID: PMC4762796 DOI: 10.1007/s12178-016-9321-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metal-on-metal (MOM) bearing surfaces in hip arthroplasty have distinct advantages that led to the increase in popularity in North America in the early 2000s. However, with their increased use, concerns such as local cytotoxicity and hypersensitivity reactions leading to soft tissue damage and cystic mass formation (known collectively as adverse local tissue reactions (ALTR)) became apparent. The clinical presentation of ALTR is highly variable. The diagnosis of ALTR in MOM articulations in hip arthroplasty can be challenging and a combination of clinical presentation, physical examination, implant track record, component positioning, serum metal ion levels, cross-sectional imaging, histopathologic analysis, and consideration of alternative diagnoses are essential.
Collapse
Affiliation(s)
- Brian P Chalmers
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Kevin I Perry
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Michael J Taunton
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Tad M Mabry
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
| |
Collapse
|
36
|
Silverman EJ, Ashley B, Sheth NP. Metal-on-metal total hip arthroplasty: is there still a role in 2016? Curr Rev Musculoskelet Med 2016; 9:93-6. [PMID: 26791173 DOI: 10.1007/s12178-016-9323-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The use of metal-on-metal (MoM) bearings in total hip arthroplasty (THA) was popularized due to its enhanced wear profile and the ability to use large femoral heads to reduce post-operative instability. However, enthusiasm for the bearing declined following serious complications encountered at the primary articulation. This review discusses the development of MoM and the subsequent unexpected downstream challenges, most notably elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL), pseudotumor formation, and subsequent soft tissue and bone destruction. Both patient centered risk factors as well as component design led to high early failure rates resulting in product recalls and an overall decline in the use of MoM. In 2016, there is not a role for large-head MoM bearing in THA. Alternatively, the bearing has shown promise in hip resurfacing procedures for carefully selected patients.
Collapse
Affiliation(s)
- Edward J Silverman
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| | - Blair Ashley
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| | - Neil P Sheth
- Department of Orthopaedics, The University of Pennsylvania Health System, 800 Spruce Street, Philadelphia, PA, 19107, USA.
| |
Collapse
|
37
|
Harrington K, Phelan E, Torreggiani WC, Doody O. The Management of the Symptomatic Patient With a Metal-on-Metal Hip Prosthesis. Can Assoc Radiol J 2016; 67:76-81. [PMID: 26800622 DOI: 10.1016/j.carj.2015.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 09/28/2015] [Accepted: 10/05/2015] [Indexed: 11/26/2022] Open
Abstract
Metal-on-metal (MoM) hip implants have gained popularity due to their greater stability and reduction in implant failure compare to metal-on-polyethylene prostheses. However, as well as carrying general risks of hip implantation, risks specifically associated with MoM implants have been well documented in recent years. Conditions such as pseudotumours or aseptic lymphocyte-dominated vasculitis-associated lesions are specific to MoM hip implants. In this review we discuss the typical patient presentation, the investigations that should be performed, the typical findings on various imaging modalities, and the treatment options of symptomatic patients with MoM hip arthroplasties.
Collapse
Affiliation(s)
- Kate Harrington
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland.
| | - Emma Phelan
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| | - William C Torreggiani
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| | - Orla Doody
- Radiology Department, The Adelaide and Meath Hospital Dublin, Incorporating the National Children's Hospital, Dublin, Ireland
| |
Collapse
|
38
|
Matsen Ko L, Coleman JJ, Stas V, Duwelius PJ. Iliopsoas Irritation as Presentation of Head-Neck Corrosion After Total Hip Arthroplasty: A Case Series. Orthop Clin North Am 2015; 46:461-8. [PMID: 26410635 DOI: 10.1016/j.ocl.2015.06.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Corrosion of modular components at the femoral neck remains a complication of total hip arthroplasty (THA). The authors have found the iliopsoas sign (pain on resisted flexion of the hip) to be suggestive of femoral component corrosion. These cases represented 8 of 120 revision hip arthroplasties (7%) performed at the authors' institution. After the revisions, all iliopsoas tendonitis symptoms resolved. Based on the authors' experience and the recent literature, they recommend that the iliopsoas sign or presentation of a sterile iliopsoas abscess in a previously well-functioning THA be concern for corrosion of the femoral component of the total hip.
Collapse
Affiliation(s)
- Laura Matsen Ko
- Orthopedic + Fracture Specialists, Providence St. Vincent Medical Center, 11782 Southwest Barnes Road #300, Portland, OR 97225, USA
| | - Jacob J Coleman
- Providence Health & Services, Orthopedic Institute, 5251 Northeast Glisan Street, Building A, Suite 326, Portland, OR 97213, USA.
| | - Venessa Stas
- Orthopedic + Fracture Specialists, Providence St. Vincent Medical Center, 11782 Southwest Barnes Road #300, Portland, OR 97225, USA
| | - Paul J Duwelius
- Orthopedic + Fracture Specialists, Providence St. Vincent Medical Center, 11782 Southwest Barnes Road #300, Portland, OR 97225, USA
| |
Collapse
|
39
|
Affiliation(s)
- James T Ninomiya
- Department of Orthopaedic Surgery, FMLH Specialty Clinics Building, Medical College of Wisconsin, 5200 West Wisconsin Avenue, Milwaukee, WI 53226. E-mail address:
| | - John C Dean
- West Texas Orthopedics, 10 Desta Drive, Suite 100E, Midland, TX 79705
| | - Stephen J Incavo
- Houston Methodist Hospital, Smith Tower, 6550 Fannin Street, Suite 2600, Houston, TX 77030
| |
Collapse
|
40
|
Matharu GS, Mellon SJ, Murray DW, Pandit HG. Follow-Up of Metal-on-Metal Hip Arthroplasty Patients Is Currently Not Evidence Based or Cost Effective. J Arthroplasty 2015; 30:1317-23. [PMID: 25861918 DOI: 10.1016/j.arth.2015.03.009] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 02/19/2015] [Accepted: 03/07/2015] [Indexed: 02/01/2023] Open
Abstract
Over one-million patients worldwide have received metal-on-metal (MoM) hip arthroplasties with a significant proportion requiring revision surgery in the short-term for adverse reaction to metal debris (ARMD). Worldwide authorities have subsequently issued follow-up guidance for MoM hip patients. This article compares follow-up guidelines for MoM hips published by five worldwide authorities, analyses these protocols in relation to published evidence, and assesses the financial implications of these guidelines. A number of major differences exist between authorities regarding patient follow-up, with vast cost differences between protocols (£84 to £988/patient/year for stemmed MoM hips and £0 to £988/patient/year for hip resurfacing). Current worldwide guidance is neither evidence-based nor financially sustainable with most protocols lacking the sensitivity to detect asymptomatic ARMD lesions.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - Stephen J Mellon
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| |
Collapse
|