1
|
Meira E Cruz M, Chen E, Zhou Y, Shu D, Zhou C, Kryger M. A wearable ring oximeter for detection of sleep disordered breathing. Respir Med 2025; 242:108092. [PMID: 40220874 DOI: 10.1016/j.rmed.2025.108092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2025] [Revised: 04/05/2025] [Accepted: 04/07/2025] [Indexed: 04/14/2025]
Abstract
INTRODUCTION Wearable devices have been developed that can continuously monitor physiologic variables. One device, Circul® (Bodimetrics Corp, Los Angeles, CA), with a form factor of a ring, measures several variables (SpO2, movement, heart rate). OBJECTIVES To evaluate the potential utility of this device in detecting sleep breathing disorders. MATERIALS AND METHODS OSA severity measured by the oxygen desaturation Index (ODI) using a wearable oximetric Circul® ring (ODI as defined by 3 % desaturation - cODI3 %) was compared with the gold standard, polysomnography (PSG) in patients suspected of having sleep-disordered breathing. The Circul data was autoscored by the device's software; a technician scored the PSG data. The sensitivity (S), and specificity (E) for the different thresholds for cODI3 % compared to the PSG AHI and PSG ODI, were calculated. RESULTS 164 patients (age = 44.8 years + 12.3 (SD)) were enrolled. Using the PSG-derived AHI as the reference for classification, the best cut-off points were: OSA = AHI ≥ 5: cODI3 % ≥ 4.3 (S 87.8 %, E 93.8 %); OSA = AHI ≥ 15: cODI3 % ≥ 13.1 (S 76 %, E 100 %); OSA = AHI ≥ 30 = : cODI3 % ≥ 16.2 (S 85.7 %, E 92 %); Using the ODI from the PSG as the reference for classification, the respective cut-off points were: OSA=ODI ≥ 5: cODI3 % ≥ 4.3 (S 93.4 %, E 88.9 %); OSA=ODI ≥ 15:cODI3 % ≥ 13.1 (S85.2 %, E98.4 %); OSA=ODI ≥ 30: cODI3 % ≥ 18.7 (S 98.4 %, E 92.2 %). CONCLUSIONS Circul® oximetry demonstrated good diagnostic accuracy compared to the gold standard in determining OSA severity. cODI3 % greater than 13 suggests that significant OSA might be present.
Collapse
Affiliation(s)
- Miguel Meira E Cruz
- Sleep Unit, Centro Cardiovascular da Universidade de Lisboa, Lisbon School of Medicine, Lisbon, Portugal and European Sleep Center, Lisbon, Portugal.
| | - Enguo Chen
- Zhejiang University, School of Medicine, Sir Run Run Shaw Hospital, Zhejiang, China
| | - Yong Zhou
- Zhejiang University, School of Medicine, Sir Run Run Shaw Hospital, Zhejiang, China
| | - Dengui Shu
- Zhejiang University, School of Medicine, Sir Run Run Shaw Hospital, Zhejiang, China
| | - Congcong Zhou
- Zhejiang University, School of Medicine, Sir Run Run Shaw Hospital, Zhejiang, China
| | - Meir Kryger
- Yale School of Medicine, New Haven, CT, United States
| |
Collapse
|
2
|
Finnsson E, Erlingsson E, Hlynsson HD, Valsdóttir V, Sigmarsdottir TB, Arnardóttir E, Sands SA, Jónsson SÆ, Islind AS, Ágústsson JS. Detecting arousals and sleep from respiratory inductance plethysmography. Sleep Breath 2025; 29:155. [PMID: 40214714 PMCID: PMC11991959 DOI: 10.1007/s11325-025-03325-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Revised: 02/24/2025] [Accepted: 04/02/2025] [Indexed: 04/14/2025]
Abstract
PURPOSE Accurately identifying sleep states (REM, NREM, and Wake) and brief awakenings (arousals) is essential for diagnosing sleep disorders. Polysomnography (PSG) is the gold standard for such assessments but is costly and requires overnight monitoring in a lab. Home sleep testing (HST) offers a more accessible alternative, relying primarily on breathing measurements but lacks electroencephalography, limiting its ability to evaluate sleep and arousals directly. This study evaluates a deep learning algorithm which determines sleep states and arousals from breathing signals. METHODS A novel deep learning algorithm was developed to classify sleep states and detect arousals from respiratory inductance plethysmography signals. Sleep states were predicted for 30-s intervals (one sleep epoch), while arousal probabilities were calculated at 1-s resolution. Validation was conducted on a clinical dataset of 1,299 adults with suspected sleep disorders. Performance was assessed at the epoch level for sensitivity and specificity, with agreement analyses for arousal index (ArI) and total sleep time (TST). RESULTS The algorithm achieved sensitivity and specificity of 77.9% and 96.2% for Wake, 93.9% and 80.4% for NREM, 80.5% and 98.2% for REM, and 66.1% and 86.7% for arousals. Bland-Altman analysis showed ArI limits of agreement ranging from - 32 to 24 events/hour (bias: - 4.4) and TST limits from - 47 to 64 min (bias: 8.0). Intraclass correlation was 0.74 for ArI and 0.91 for TST. CONCLUSION The algorithm identifies sleep states and arousals from breathing signals with agreement comparable to established variability in manual scoring. These results highlight its potential to advance HST capabilities, enabling more accessible, cost-effective and reliable sleep diagnostics.
Collapse
Affiliation(s)
- Eysteinn Finnsson
- Nox Research, Nox Medical, Katrínartún 2, 105, Reykjavík, Iceland.
- Department of Computer Science, Reykjavik University, Reykjavik, Iceland.
| | - Ernir Erlingsson
- Nox Research, Nox Medical, Katrínartún 2, 105, Reykjavík, Iceland
- Department of Computer Science, University of Iceland, Reykjavik, Iceland
| | | | - Vaka Valsdóttir
- Nox Research, Nox Medical, Katrínartún 2, 105, Reykjavík, Iceland
| | | | | | - Scott A Sands
- Division of Sleep and Circadian Disorders, Department of Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA
| | | | - Anna S Islind
- Department of Computer Science, Reykjavik University, Reykjavik, Iceland
| | - Jón S Ágústsson
- Nox Research, Nox Medical, Katrínartún 2, 105, Reykjavík, Iceland
| |
Collapse
|
3
|
Martinot JB, Le-Dong NN, Malhotra A, Pépin JL. Enhancing artificial intelligence-driven sleep apnea diagnosis: The critical importance of input signal proficiency with a focus on mandibular jaw movements. J Prosthodont 2025; 34:10-25. [PMID: 39676388 PMCID: PMC12003084 DOI: 10.1111/jopr.14003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Accepted: 11/22/2024] [Indexed: 12/17/2024] Open
Abstract
PURPOSE This review aims to highlight the pivotal role of the mandibular jaw movement (MJM) signal in advancing artificial intelligence (AI)-powered technologies for diagnosing obstructive sleep apnea (OSA). METHODS A scoping review was conducted to evaluate various aspects of the MJM signal and their contribution to improving signal proficiency for users. RESULTS The comprehensive literature analysis is structured into four key sections, each addressing factors essential to signal proficiency. These factors include (1) the comprehensiveness of research, development, and application of MJM-based technology; (2) the physiological significance of the MJM signal for various clinical tasks; (3) the technical transparency; and (4) the interpretability of the MJM signal. Comparisons with the photoplethysmography (PPG) signal are made where applicable. CONCLUSIONS Proficiency in biosignal interpretation is essential for the success of AI-driven diagnostic tools and for maximizing the clinical benefits through enhanced physiological insight. Through rigorous research ensuring an enhanced understanding of the signal and its extensive validation, the MJM signal sets a new benchmark for the development of AI-driven diagnostic solutions in OSA diagnosis.
Collapse
Affiliation(s)
- Jean-Benoit Martinot
- Sleep Laboratory, CHU Université catholique de Louvain (UCL), Namur Site Sainte-Elisabeth, Namur, Belgium
- Institute of Experimental and Clinical Research, UCL Bruxelles Woluwe, Brussels, Belgium
| | | | - Atul Malhotra
- University of California San Diego, La Jolla, California, USA
| | - Jean-Louis Pépin
- HP2 Laboratory, Inserm U1300, Grenoble Alpes University, Grenoble, France
- EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France
| |
Collapse
|
4
|
Thomas RJ. REM sleep breathing: Insights beyond conventional respiratory metrics. J Sleep Res 2025; 34:e14270. [PMID: 38960862 DOI: 10.1111/jsr.14270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 05/29/2024] [Indexed: 07/05/2024]
Abstract
Breathing and sleep state are tightly linked. The traditional approach to evaluation of breathing in rapid eye movement sleep has been to focus on apneas and hypopneas, and associated hypoxia or hypercapnia. However, rapid eye movement sleep breathing offers novel insights into sleep physiology and pathology, secondary to complex interactions of rapid eye movement state and cardiorespiratory biology. In this review, morphological analysis of clinical polysomnogram data to assess respiratory patterns and associations across a range of health and disease is presented. There are several relatively unique insights that may be evident by assessment of breathing during rapid eye movement sleep. These include the original discovery of rapid eye movement sleep and scoring of neonatal sleep, control of breathing in rapid eye movement sleep, rapid eye movement sleep homeostasis, sleep apnea endotyping and pharmacotherapy, rapid eye movement sleep stability, non-electroencephalogram sleep staging, influences on cataplexy, mimics of rapid eye movement behaviour disorder, a reflection of autonomic health, and insights into cardiac arrhythmogenesis. In summary, there is rich clinically actionable information beyond sleep apnea encoded in the respiratory patterns of rapid eye movement sleep.
Collapse
Affiliation(s)
- Robert Joseph Thomas
- Department of Medicine, Division of Pulmonary Critical Care & Sleep Medicine, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
5
|
Pal R, Rudas A, Williams T, Chiang JN, Barney A, Cannesson M. Feature Extraction Tool Using Temporal Landmarks in Arterial Blood Pressure and Photoplethysmography Waveforms. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2025:2025.03.20.25324325. [PMID: 40166581 PMCID: PMC11957180 DOI: 10.1101/2025.03.20.25324325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 04/02/2025]
Abstract
Arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms both contain vital physiological information for the prevention and treatment of cardiovascular diseases. Extracted features from these waveforms have diverse clinical applications, including predicting hyper- and hypo-tension, estimating cardiac output from ABP, and monitoring blood pressure and nociception from PPG. However, the lack of standardized tools for feature extraction limits their exploration and clinical utilization. In this study, we propose an automatic feature extraction tool that first detects temporal location of landmarks within each cardiac cycle of ABP and PPG waveforms, including the systolic phase onset, systolic phase peak, dicrotic notch, and diastolic phase peak using the iterative envelope mean method. Then, based on these landmarks, extracts 852 features per cardiac cycle, encompassing time-, statistical-, and frequency-domains. The tool's ability to detect landmarks was evaluated using ABP and PPG waveforms from a large perioperative dataset (MLORD dataset) comprising 17,327 patients. We analyzed 34,267 cardiac cycles of ABP waveforms and 33,792 cardiac cycles of PPG waveforms. Additionally, to assess the tool's real-time landmark detection capability, we retrospectively analyzed 3,000 cardiac cycles of both ABP and PPG waveforms, collected from a Philips IntelliVue MX800 patient monitor. The tool's detection performance was assessed against markings by an experienced researcher, achieving average F1-scores and error rates for ABP and PPG as follows: (1) On MLORD dataset: systolic phase onset (99.77 %, 0.35 % and 99.52 %, 0.75 %), systolic phase peak (99.80 %, 0.30 % and 99.56 %, 0.70 %), dicrotic notch (98.24 %, 2.63 % and 98.72 %, 1.96 %), and diastolic phase peak (98.59 %, 2.11 % and 98.88 %, 1.73 %); (2) On real time data: systolic phase onset (98.18 %, 3.03 % and 97.94 %, 3.43 %), systolic phase peak (98.22 %, 2.97 % and 97.74 %, 3.77 %), dicrotic notch (97.72 %, 3.80 % and 98.16 %, 3.07 %), and diastolic phase peak (98.04 %, 3.27 % and 98.08 %, 3.20 %). This tool has significant potential for supporting clinical utilization of ABP and PPG waveform features and for facilitating feature-based machine learning models for various clinical applications where features derived from these waveforms play a critical role.
Collapse
Affiliation(s)
- Ravi Pal
- Department of Anesthesiology & Perioperative Medicine, University of California, Los Angeles, CA, USA
| | - Akos Rudas
- Department of Computational Medicine, University of California, Los Angeles, CA, USA
| | - Tiffany Williams
- Department of Anesthesiology & Perioperative Medicine, University of California, Los Angeles, CA, USA
| | - Jeffrey N. Chiang
- Department of Computational Medicine, University of California, Los Angeles, CA, USA
| | - Anna Barney
- Institute of Sound and Vibration Research (ISVR), University of Southampton, Southampton, United Kingdom
| | - Maxime Cannesson
- Department of Anesthesiology & Perioperative Medicine, University of California, Los Angeles, CA, USA
| |
Collapse
|
6
|
van der Aar JF, van Gilst MM, van den Ende DA, van Gorp H, Anderer P, Pijpers A, Fonseca P, Peri E, Overeem S. Hypnogram and Hypnodensity Analysis of REM Sleep Behaviour Disorder Using Both EEG and HRV-Based Sleep Staging Models. J Sleep Res 2025:e70046. [PMID: 40077890 DOI: 10.1111/jsr.70046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2024] [Revised: 02/10/2025] [Accepted: 03/06/2025] [Indexed: 03/14/2025]
Abstract
Rapid-eye-movement (REM) sleep behaviour disorder (RBD) is a primary sleep disorder strongly associated with Parkinson's disease. Assessing sleep structure in RBD is important for understanding the underlying pathophysiology and developing diagnostic methods. However, the performance of automated sleep stage classification (ASSC) models is considered suboptimal in RBD, for both models utilising neurological signals ("ExG": EEG, EOG, and chin EMG) and heart rate variability combined with body movements (HRVm). Here, we explore this underperformance through the categorical representation of sleep macrostructure (i.e., hypnogram) and a representation that leverages the underlying probability distribution of ASSCs (i.e., hypnodensity). By comparing the RBD population (n = 36) to a sex- and age-matched group of OSA patients chosen for their anticipated similarly decreased sleep stability, we confirm lower 4-stage classification performance in both ExG-based ASSC (RBD: κ = 0.74, OSA: κ = 0.80) and HRVm-based ASSC (RBD: κ = 0.50, OSA: κ = 0.63). Stages showing lower agreement in RBD, namely, N1 + N2 and REM sleep, exhibited elevated ambiguity in the hypnodensity, indicating more ambiguous classification distributions. Limited differences in bout durations between RBD and OSA suggested sleep instability is not necessarily driving lower agreement in RBD. However, stage transitions in OSA showed more abrupt changes in the underlying probability distribution, while RBD transitions had a more continuous profile, possibly complicating classification. Although both ExG-based and HRVm-based automated sleep staging in RBD remain challenging, hypnodensity analysis is informative for the characterisation of (RBD) sleep and can capture potential drivers of classification disagreement.
Collapse
Affiliation(s)
- Jaap F van der Aar
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Philips Sleep and Respiratory Care, Eindhoven, the Netherlands
| | - Merel M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Center for Sleep Medicine Kempenhaeghe, Heeze, the Netherlands
| | - Daan A van den Ende
- Philips Innovation & Strategy, Department of Innovation Engineering, Eindhoven, the Netherlands
| | - Hans van Gorp
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Philips Sleep and Respiratory Care, Eindhoven, the Netherlands
| | - Peter Anderer
- The Siesta Group Schlafanalyse Gmbh, Vienna, Austria
| | | | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Philips Sleep and Respiratory Care, Eindhoven, the Netherlands
| | - Elisabetta Peri
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Center for Sleep Medicine Kempenhaeghe, Heeze, the Netherlands
| |
Collapse
|
7
|
van den Brink WJ, Oosterman JE, Smid DJ, de Vries HJ, Atsma DE, Overeem S, Wopereis S. Sleep as a window of cardiometabolic health: The potential of digital sleep and circadian biomarkers. Digit Health 2025; 11:20552076241288724. [PMID: 39980570 PMCID: PMC11840856 DOI: 10.1177/20552076241288724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Accepted: 09/13/2024] [Indexed: 02/22/2025] Open
Abstract
Digital biomarkers are quantifiable and objective indicators of a person's physiological function, behavioral state or treatment response, that can be captured using connected sensor technologies such as wearable devices and mobile apps. We envision that continuous and 24-h monitoring of the underlying physiological and behavioral processes through digital biomarkers can enhance early diagnostics, disease management, and self-care of cardiometabolic diseases. Cardiometabolic diseases, which include a combination of cardiovascular and metabolic disorders, represent an emerging global health threat. The prevention potential of cardiometabolic diseases is around 80%, indicating a promising role for interventions in the lifestyle and/or the environmental context. Disruption of sleep and circadian rhythms are increasingly recognized as risk factors for cardiometabolic disease. Digital biomarkers can be used to measure around the clock, that is, day and night, to quantify not only sleep patterns but also diurnal fluctuations of certain biomarkers and processes. In this way, digital biomarkers can support the delivery of optimal timed medical care. Night-time cardiometabolic patterns, such as blood pressure dipping, are predictive of cardiometabolic health outcomes. In addition, the sleep period provides an opportunity for digital cardiometabolic health monitoring with relatively low influence of artifacts, such as physical activity and eating. Digital biomarkers that utilize sleep as a window of health can be used during daily life to enable early diagnosis of cardiometabolic diseases, facilitate remote patient monitoring, and support self-management in people with cardiometabolic diseases. This review describes the influence of sleep and circadian rhythms on cardiometabolic disease and highlights the state-of-the-art sleep and circadian digital biomarkers which could be of benefit in the prevention of cardiometabolic disease.
Collapse
Affiliation(s)
- Willem J van den Brink
- Research Group Microbiology and Systems Biology, Netherlands Organization for Applied Scientific Research (TNO), Leiden, The Netherlands
| | - Johanneke E Oosterman
- Research Group Microbiology and Systems Biology, Netherlands Organization for Applied Scientific Research (TNO), Leiden, The Netherlands
| | - Dagmar J Smid
- Research Group Microbiology and Systems Biology, Netherlands Organization for Applied Scientific Research (TNO), Leiden, The Netherlands
| | - Herman J de Vries
- Research Group Learning & Workforce Development, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, The Netherlands
| | - Douwe E Atsma
- Department of Cardiology, Leiden University Medical Centre, Leiden, The Netherlands
| | - Sebastiaan Overeem
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Suzan Wopereis
- Research Group Microbiology and Systems Biology, Netherlands Organization for Applied Scientific Research (TNO), Leiden, The Netherlands
| |
Collapse
|
8
|
Kuhn J, Schiphorst LRB, Wulterkens BM, Asin J, Duis N, Overeem S, van Gilst MM, Fonseca P. Multi-Night Home Assessment of Total Sleep Time Misperception in Obstructive Sleep Apnea with and Without Insomnia Symptoms. Clocks Sleep 2024; 6:777-788. [PMID: 39727626 DOI: 10.3390/clockssleep6040050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Revised: 11/20/2024] [Accepted: 12/03/2024] [Indexed: 12/28/2024] Open
Abstract
Total sleep time (TST) misperception has been reported in obstructive sleep apnea (OSA). However, previous findings on predictors were inconsistent and predominantly relied on single-night polysomnography, which may alter patients' sleep perception. We leveraged advances in wearable sleep staging to investigate predictors of TST misperception in OSA over multiple nights in the home environment. The study included 141 patients with OSA, 75 without insomnia symptoms (OSA group), and 66 with insomnia symptoms (OSA-I group). Objective TST was measured using a previously validated wrist-worn photoplethysmography and accelerometry device. Self-reported TST was assessed using a digital sleep diary. TST misperception was quantified with the misperception index (MI), calculated as (objective - self-reported TST)/objective TST. MI values differed significantly between the OSA (median = -0.02, IQR = [-0.06, 0.02]) and the OSA-I group (0.05, [-0.02, 0.13], p < 0.001). Multilevel modeling revealed that the presence of insomnia symptoms (β = 0.070, p < 0.001) and lower daily reported sleep quality (β = -0.229, p < 0.001) were predictive of higher MI (TST underestimation), while a higher apnea-hypopnea index (AHI) was predictive of lower MI (TST overestimation; β = -0.001, p = 0.006). Thus, insomnia symptoms and AHI are associated with TST misperception in OSA patients, but in opposite directions. This association extends over multiple nights in the home environment.
Collapse
Affiliation(s)
- Jasmin Kuhn
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656AE Eindhoven, The Netherlands
| | - Laura R B Schiphorst
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656AE Eindhoven, The Netherlands
| | - Bernice M Wulterkens
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656AE Eindhoven, The Netherlands
| | - Jerryll Asin
- Center for Sleep Medicine, Amphia Hospital, 4818CK Breda, The Netherlands
| | - Nanny Duis
- Center for Sleep Medicine, Amphia Hospital, 4818CK Breda, The Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591VE Heeze, The Netherlands
| | - Merel M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591VE Heeze, The Netherlands
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656AE Eindhoven, The Netherlands
| |
Collapse
|
9
|
Hong W. Twistable and Stretchable Nasal Patch for Monitoring Sleep-Related Breathing Disorders Based on a Stacking Ensemble Learning Model. ACS APPLIED MATERIALS & INTERFACES 2024; 16:47337-47347. [PMID: 39192683 DOI: 10.1021/acsami.4c11493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
Obstructive sleep apnea syndrome disrupts sleep, destroys the homeostasis of biological systems such as metabolism and the immune system, and reduces learning ability and memory. The existing polysomnography used to measure sleep disorders is executed in an unfamiliar environment, which may result in sleep patterns that are different from usual, reducing accuracy. This study reports a machine learning-based personalized twistable patch system that can simply measure obstructive sleep apnea syndrome in daily life. The stretchable patch attaches directly to the nose in an integrated form factor, detecting sleep-disordered breathing by simultaneously sensing microscopic vibrations and airflow in the nasal cavity and paranasal sinuses. The highly sensitive multichannel patch, which can detect airflow at the level of 0.1 m/s, has flexibility via a unique slit pattern and fabric layer. It has linearity with an R2 of 0.992 in the case of the amount of change according to its curvature. The stacking ensemble learning model predicted the degree of sleep-disordered breathing with an accuracy of 92.9%. The approach demonstrates high sleep disorder detection capacity and proactive visual notification. It is expected to help as a diagnostic platform for the early detection of chronic diseases such as cerebrovascular disease and diabetes.
Collapse
Affiliation(s)
- Wonki Hong
- Department of Digital Healthcare, Daejeon University, Daejeon 34520, Republic of Korea
| |
Collapse
|
10
|
Schipper F, Grassi A, Ross M, Cerny A, Anderer P, Hermans L, van Meulen F, Leentjens M, Schoustra E, Bosschieter P, van Sloun RJG, Overeem S, Fonseca P. Overnight Sleep Staging Using Chest-Worn Accelerometry. SENSORS (BASEL, SWITZERLAND) 2024; 24:5717. [PMID: 39275628 PMCID: PMC11398147 DOI: 10.3390/s24175717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 08/14/2024] [Accepted: 08/28/2024] [Indexed: 09/16/2024]
Abstract
Overnight sleep staging is an important part of the diagnosis of various sleep disorders. Polysomnography is the gold standard for sleep staging, but less-obtrusive sensing modalities are of emerging interest. Here, we developed and validated an algorithm to perform "proxy" sleep staging using cardiac and respiratory signals derived from a chest-worn accelerometer. We collected data in two sleep centers, using a chest-worn accelerometer in combination with full PSG. A total of 323 participants were analyzed, aged 13-83 years, with BMI 18-47 kg/m2. We derived cardiac and respiratory features from the accelerometer and then applied a previously developed method for automatic cardio-respiratory sleep staging. We compared the estimated sleep stages against those derived from PSG and determined performance. Epoch-by-epoch agreement with four-class scoring (Wake, REM, N1+N2, N3) reached a Cohen's kappa coefficient of agreement of 0.68 and an accuracy of 80.8%. For Wake vs. Sleep classification, an accuracy of 93.3% was obtained, with a sensitivity of 78.7% and a specificity of 96.6%. We showed that cardiorespiratory signals obtained from a chest-worn accelerometer can be used to estimate sleep stages among a population that is diverse in age, BMI, and prevalence of sleep disorders. This opens up the path towards various clinical applications in sleep medicine.
Collapse
Affiliation(s)
- Fons Schipper
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656 AE Eindhoven, The Netherlands
| | - Angela Grassi
- Philips Sleep and Respiratory Care, 5656 AE Eindhoven, The Netherlands
| | - Marco Ross
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- The Siesta Group, 1210 Vienna, Austria
| | | | | | - Lieke Hermans
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
| | - Fokke van Meulen
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- Center for Sleep Medicine Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Mickey Leentjens
- Department of Otorhinolaryngology, Head and Neck Surgery OLVG West, 1061 AE Amsterdam, The Netherlands
| | - Emily Schoustra
- Department of Otorhinolaryngology, Head and Neck Surgery OLVG West, 1061 AE Amsterdam, The Netherlands
| | - Pien Bosschieter
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- Center for Sleep Medicine Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Ruud J G van Sloun
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- Center for Sleep Medicine Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, 5656 AE Eindhoven, The Netherlands
| |
Collapse
|
11
|
Olsen M, Zeitzer JM, Nakase-Richardson R, Musgrave VH, Sorensen HBD, Mignot E, Jennum PJ. A Deep Transfer Learning Approach for Sleep Stage Classification and Sleep Apnea Detection Using Wrist-Worn Consumer Sleep Technologies. IEEE Trans Biomed Eng 2024; 71:2506-2517. [PMID: 38498753 DOI: 10.1109/tbme.2024.3378480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Obstructive sleep apnea (OSA) is a common, underdiagnosed sleep-related breathing disorder with serious health implications Objective - We propose a deep transfer learning approach for sleep stage classification and sleep apnea (SA) detection using wrist-worn consumer sleep technologies (CST). Methods - Our model is based on a deep convolutional neural network (DNN) utilizing accelerometers and photo-plethysmography signals from nocturnal recordings. The DNN was trained and tested on internal datasets that include raw data from clinical and wrist-worn devices; external validation was performed on a hold-out test dataset containing raw data from a wrist-worn CST. Results - Training on clinical data improves performance significantly, and feature enrichment through a sleep stage stream gives only minor improvements. Raw data input outperforms feature-based input in CST datasets. The system generalizes well but performs slightly worse on wearable device data compared to clinical data. However, it excels in detecting events during REM sleep and is associated with arousal and oxygen desaturation. We found; cases that were significantly underestimated were characterized by fewer of such event associations. Conclusion - This study showcases the potential of using CSTs as alternate screening solution for undiagnosed cases of OSA. Significance - This work is significant for its development of a deep transfer learning approach using wrist-worn consumer sleep technologies, offering comprehensive validation for data utilization, and learning techniques, ultimately improving sleep apnea detection across diverse devices.
Collapse
|
12
|
Blaskovich B, Bullón-Tarrasó E, Pöhlchen D, Manafis A, Neumayer H, Besedovsky L, Brückl T, Simor P, Binder FP, Spoormaker VI. The utility of wearable headband electroencephalography and pulse photoplethysmography to assess cortical and physiological arousal in individuals with stress-related mental disorders. J Sleep Res 2024; 33:e14123. [PMID: 38099396 DOI: 10.1111/jsr.14123] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 11/16/2023] [Accepted: 11/27/2023] [Indexed: 07/17/2024]
Abstract
Several stress-related mental disorders are characterised by disturbed sleep, but objective sleep biomarkers are not routinely examined in psychiatric patients. We examined the use of wearable-based sleep biomarkers in a psychiatric sample with headband electroencephalography (EEG) including pulse photoplethysmography (PPG), with an additional focus on microstructural elements as especially the shift from low to high frequencies appears relevant for several stress-related mental disorders. We analysed 371 nights of sufficient quality from 83 healthy participants and those with a confirmed stress-related mental disorder (anxiety-affective spectrum). The median value of macrostructural, microstructural (spectral slope fitting), and heart rate variables was calculated across nights and analysed at the individual level (N = 83). The headbands were accepted well by patients and the data quality was sufficient for most nights. The macrostructural analyses revealed trends for significance regarding sleep continuity but not sleep depth variables. The spectral analyses yielded no between-group differences except for a group × age interaction, with the normal age-related decline in the low versus high frequency power ratio flattening in the patient group. The PPG analyses showed that the mean heart rate was higher in the patient group in pre-sleep epochs, a difference that reduced during sleep and dissipated at wakefulness. Wearable devices that record EEG and/or PPG could be used over multiple nights to assess sleep fragmentation, spectral balance, and sympathetic drive throughout the sleep-wake cycle in patients with stress-related mental disorders and healthy controls, although macrostructural and spectral markers did not differ between the two groups.
Collapse
Affiliation(s)
- Borbala Blaskovich
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
- Institute of Medical Psychology, Faculty of Medicine, LMU Munich, Munich, Germany
| | | | - Dorothee Pöhlchen
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| | - Alexandros Manafis
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| | - Hannah Neumayer
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| | - Luciana Besedovsky
- Institute of Medical Psychology, Faculty of Medicine, LMU Munich, Munich, Germany
| | - Tanja Brückl
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| | - Peter Simor
- Institute of Psychology, ELTE, Eötvös Loránd University, Budapest, Hungary
- Institute of Behavioral Sciences, Semmelweis University, Budapest, Hungary
| | - Florian P Binder
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| | - Victor I Spoormaker
- Department Genes and Environment, Max Planck Institute of Psychiatry, Munich, Germany
| |
Collapse
|
13
|
Silva FB, Uribe LFS, Cepeda FX, Alquati VFS, Guimarães JPS, Silva YGA, Santos OLD, de Oliveira AA, de Aguiar GHM, Andersen ML, Tufik S, Lee W, Li LT, Penatti OA. Sleep staging algorithm based on smartwatch sensors for healthy and sleep apnea populations. Sleep Med 2024; 119:535-548. [PMID: 38810479 DOI: 10.1016/j.sleep.2024.05.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 05/06/2024] [Accepted: 05/14/2024] [Indexed: 05/31/2024]
Abstract
OBJECTIVE Sleep stages can provide valuable insights into an individual's sleep quality. By leveraging movement and heart rate data collected by modern smartwatches, it is possible to enable the sleep staging feature and enhance users' understanding about their sleep and health conditions. METHOD In this paper, we present and validate a recurrent neural network based model with 23 input features extracted from accelerometer and photoplethysmography sensors data for both healthy and sleep apnea populations. We designed a lightweight and fast solution to enable the prediction of sleep stages for each 30-s epoch. This solution was developed using a large dataset of 1522 night recordings collected from a highly heterogeneous population and different versions of Samsung smartwatch. RESULTS In the classification of four sleep stages (wake, light, deep, and rapid eye movements sleep), the proposed solution achieved 71.6 % of balanced accuracy and a Cohen's kappa of 0.56 in a test set with 586 recordings. CONCLUSION The results presented in this paper validate our proposal as a competitive wearable solution for sleep staging. Additionally, the use of a large and diverse data set contributes to the robustness of our solution, and corroborates the validation of algorithm's performance. Some additional analysis performed for healthy and sleep apnea population demonstrated that algorithm's performance has low correlation with demographic variables.
Collapse
Affiliation(s)
- Fernanda B Silva
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil.
| | - Luisa F S Uribe
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil.
| | - Felipe X Cepeda
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil
| | - Vitor F S Alquati
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil
| | | | - Yuri G A Silva
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil
| | | | | | | | - Monica L Andersen
- Sleep Institute, São Paulo, SP, 04020-060, Brazil; Departamento de Psicobiologia, Universidade Federal de São Paulo, São Paulo, SP, 04724-000, Brazil
| | - Sergio Tufik
- Sleep Institute, São Paulo, SP, 04020-060, Brazil; Departamento de Psicobiologia, Universidade Federal de São Paulo, São Paulo, SP, 04724-000, Brazil
| | - Wonkyu Lee
- Samsung Electronics, Suwon, 16677, Republic of Korea
| | - Lin Tzy Li
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil
| | - Otávio A Penatti
- Samsung R&D Institute Brazil (SRBR), Campinas, SP, 13097-160, Brazil
| |
Collapse
|
14
|
Jones AM, Itti L, Sheth BR. Expert-level sleep staging using an electrocardiography-only feed-forward neural network. Comput Biol Med 2024; 176:108545. [PMID: 38749325 DOI: 10.1016/j.compbiomed.2024.108545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 04/05/2024] [Accepted: 04/28/2024] [Indexed: 05/31/2024]
Abstract
Reliable classification of sleep stages is crucial in sleep medicine and neuroscience research for providing valuable insights, diagnoses, and understanding of brain states. The current gold standard method for sleep stage classification is polysomnography (PSG). Unfortunately, PSG is an expensive and cumbersome process involving numerous electrodes, often conducted in an unfamiliar clinic and annotated by a professional. Although commercial devices like smartwatches track sleep, their performance is well below PSG. To address these disadvantages, we present a feed-forward neural network that achieves gold-standard levels of agreement using only a single lead of electrocardiography (ECG) data. Specifically, the median five-stage Cohen's kappa is 0.725 on a large, diverse dataset of 5 to 90-year-old subjects. Comparisons with a comprehensive meta-analysis of between-human inter-rater agreement confirm the non-inferior performance of our model. Finally, we developed a novel loss function to align the training objective with Cohen's kappa. Our method offers an inexpensive, automated, and convenient alternative for sleep stage classification-further enhanced by a real-time scoring option. Cardiosomnography, or a sleep study conducted with ECG only, could take expert-level sleep studies outside the confines of clinics and laboratories and into realistic settings. This advancement democratizes access to high-quality sleep studies, considerably enhancing the field of sleep medicine and neuroscience. It makes less-expensive, higher-quality studies accessible to a broader community, enabling improved sleep research and more personalized, accessible sleep-related healthcare interventions.
Collapse
Affiliation(s)
- Adam M Jones
- Neuroscience Graduate Program, University of Southern California, Los Angeles, CA, USA.
| | - Laurent Itti
- Neuroscience Graduate Program, University of Southern California, Los Angeles, CA, USA
| | - Bhavin R Sheth
- Department of Electrical & Computer Engineering, University of Houston, Houston, TX, USA; Center for NeuroEngineering and Cognitive Systems, University of Houston, Houston, TX, USA
| |
Collapse
|
15
|
Proost R, Heremans E, Lagae L, Van Paesschen W, De Vos M, Jansen K. Automated sleep staging on reduced channels in children with epilepsy. Front Neurol 2024; 15:1390465. [PMID: 38798709 PMCID: PMC11116721 DOI: 10.3389/fneur.2024.1390465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/15/2024] [Indexed: 05/29/2024] Open
Abstract
Objectives This study aimed to validate a sleep staging algorithm using in-hospital video-electroencephalogram (EEG) in children without epilepsy, with well-controlled epilepsy (WCE), and with drug-resistant epilepsy (DRE). Methods Overnight video-EEG, along with electrooculogram (EOG) and chin electromyogram (EMG), was recorded in children between 4 and 18 years of age. Classical sleep staging was performed manually as a ground truth. An end-to-end hierarchical recurrent neural network for sequence-to-sequence automatic sleep staging (SeqSleepNet) was used to perform automated sleep staging using three channels: C4-A1, EOG, and chin EMG. Results In 176 children sleep stages were manually scored: 47 children without epilepsy, 74 with WCE, and 55 with DRE. The 5-class sleep staging accuracy of the automatic sleep staging algorithm was 84.7% for the children without epilepsy, 83.5% for those with WCE, and 80.8% for those with DRE (Kappa of 0.79, 0.77, and 0.73 respectively). Performance per sleep stage was assessed with an F1 score of 0.91 for wake, 0.50 for N1, 0.83 for N2, 0.84 for N3, and 0.86 for rapid eye movement (REM) sleep. Conclusion We concluded that the tested algorithm has a high accuracy in children without epilepsy and with WCE. Performance in children with DRE was acceptable, but significantly lower, which could be explained by a tendency of more time spent in N1, and by abundant interictal epileptiform discharges and intellectual disability leading to less recognizable sleep stages. REM sleep time, however, significantly affected in children with DRE, can be detected reliably by the algorithm.Clinical trial registration: ClinicalTrials.gov, identifier NCT04584385.
Collapse
Affiliation(s)
- Renee Proost
- Pediatric Neurology Department, University Hospitals Leuven, KU Leuven, Leuven, Belgium
| | - Elisabeth Heremans
- Department of Electrical Engineering (ESAT), STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, KU Leuven, Leuven, Belgium
| | - Lieven Lagae
- Pediatric Neurology Department, University Hospitals Leuven, KU Leuven, Leuven, Belgium
| | - Wim Van Paesschen
- Neurology Department, University Hospitals Leuven, KU Leuven, Leuven, Belgium
| | - Maarten De Vos
- Department of Electrical Engineering (ESAT), STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, KU Leuven, Leuven, Belgium
| | - Katrien Jansen
- Pediatric Neurology Department, University Hospitals Leuven, KU Leuven, Leuven, Belgium
| |
Collapse
|
16
|
Wulterkens BM, Den Teuling NGP, Hermans LWA, Asin J, Duis N, Overeem S, Fonseca P, van Gilst MM. Multi-night home assessment of sleep structure in OSA with and without insomnia. Sleep Med 2024; 117:152-161. [PMID: 38547592 DOI: 10.1016/j.sleep.2024.03.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 03/07/2024] [Accepted: 03/17/2024] [Indexed: 04/16/2024]
Abstract
OBJECTIVE To explore sleep structure in participants with obstructive sleep apnea (OSA) and comorbid insomnia (COMISA) and participants with OSA without insomnia (OSA-only) using both single-night polysomnography and multi-night wrist-worn photoplethysmography/accelerometry. METHODS Multi-night 4-class sleep-staging was performed with a validated algorithm based on actigraphy and heart rate variability, in 67 COMISA (23 women, median age: 51 years) and 50 OSA-only (15 women, median age: 51) participants. Sleep statistics were compared using linear regression models and mixed-effects models. Multi-night variability was explored using a clustering approach and between- and within-participant analysis. RESULTS Polysomnographic parameters showed no significant group differences. Multi-night measurements, during 13.4 ± 5.2 nights per subject, demonstrated a longer sleep onset latency and lower sleep efficiency for the COMISA group. Detailed analysis of wake parameters revealed longer mean durations of awakenings in COMISA, as well as higher numbers of awakenings lasting 5 min and longer (WKN≥5min) and longer wake after sleep onset containing only awakenings of 5 min or longer. Within-participant variance was significantly larger in COMISA for sleep onset latency, sleep efficiency, mean duration of awakenings and WKN≥5min. Unsupervised clustering uncovered three clusters; participants with consistently high values for at least one of the wake parameters, participants with consistently low values, and participants displaying higher variability. CONCLUSION Patients with COMISA more often showed extended, and more variable periods of wakefulness. These observations were not discernible using single night polysomnography, highlighting the relevance of multi-night measurements to assess characteristics indicative for insomnia.
Collapse
Affiliation(s)
- Bernice M Wulterkens
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Philips Sleep and Respiratory Care, Eindhoven, the Netherlands.
| | | | - Lieke W A Hermans
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Jerryll Asin
- Center for Sleep Medicine, Amphia Hospital, Breda, the Netherlands
| | - Nanny Duis
- Center for Sleep Medicine, Amphia Hospital, Breda, the Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Sleep Medicine Center Kempenhaeghe, Heeze, the Netherlands
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Philips Sleep and Respiratory Care, Eindhoven, the Netherlands
| | - Merel M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Sleep Medicine Center Kempenhaeghe, Heeze, the Netherlands
| |
Collapse
|
17
|
de Zambotti M, Goldstein C, Cook J, Menghini L, Altini M, Cheng P, Robillard R. State of the science and recommendations for using wearable technology in sleep and circadian research. Sleep 2024; 47:zsad325. [PMID: 38149978 DOI: 10.1093/sleep/zsad325] [Citation(s) in RCA: 30] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 12/21/2023] [Indexed: 12/28/2023] Open
Abstract
Wearable sleep-tracking technology is of growing use in the sleep and circadian fields, including for applications across other disciplines, inclusive of a variety of disease states. Patients increasingly present sleep data derived from their wearable devices to their providers and the ever-increasing availability of commercial devices and new-generation research/clinical tools has led to the wide adoption of wearables in research, which has become even more relevant given the discontinuation of the Philips Respironics Actiwatch. Standards for evaluating the performance of wearable sleep-tracking devices have been introduced and the available evidence suggests that consumer-grade devices exceed the performance of traditional actigraphy in assessing sleep as defined by polysomnogram. However, clear limitations exist, for example, the misclassification of wakefulness during the sleep period, problems with sleep tracking outside of the main sleep bout or nighttime period, artifacts, and unclear translation of performance to individuals with certain characteristics or comorbidities. This is of particular relevance when person-specific factors (like skin color or obesity) negatively impact sensor performance with the potential downstream impact of augmenting already existing healthcare disparities. However, wearable sleep-tracking technology holds great promise for our field, given features distinct from traditional actigraphy such as measurement of autonomic parameters, estimation of circadian features, and the potential to integrate other self-reported, objective, and passively recorded health indicators. Scientists face numerous decision points and barriers when incorporating traditional actigraphy, consumer-grade multi-sensor devices, or contemporary research/clinical-grade sleep trackers into their research. Considerations include wearable device capabilities and performance, target population and goals of the study, wearable device outputs and availability of raw and aggregate data, and data extraction, processing, and analysis. Given the difficulties in the implementation and utilization of wearable sleep-tracking technology in real-world research and clinical settings, the following State of the Science review requested by the Sleep Research Society aims to address the following questions. What data can wearable sleep-tracking devices provide? How accurate are these data? What should be taken into account when incorporating wearable sleep-tracking devices into research? These outstanding questions and surrounding considerations motivated this work, outlining practical recommendations for using wearable technology in sleep and circadian research.
Collapse
Affiliation(s)
- Massimiliano de Zambotti
- Center for Health Sciences, SRI International, Menlo Park, CA, USA
- Lisa Health Inc., Oakland, CA, USA
| | - Cathy Goldstein
- Sleep Disorders Center, Department of Neurology, University of Michigan-Ann Arbor, Ann Arbor, MI, USA
| | - Jesse Cook
- Department of Psychology, University of Wisconsin-Madison, Madison, WI, USA
| | - Luca Menghini
- Department of Psychology and Cognitive Science, University of Trento, Trento, Italy
| | - Marco Altini
- Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Philip Cheng
- Sleep Disorders and Research Center, Henry Ford Health, Detroit, MI, USA
| | - Rebecca Robillard
- School of Psychology, University of Ottawa, Ottawa, ON, Canada
- Canadian Sleep Research Consortium, Canada
| |
Collapse
|
18
|
Hermans L, van Meulen F, Anderer P, Ross M, Cerny A, van Gilst M, Overeem S, Fonseca P. Performance of cardiorespiratory-based sleep staging in patients using beta blockers. J Clin Sleep Med 2024; 20:575-581. [PMID: 38063156 PMCID: PMC10985295 DOI: 10.5664/jcsm.10938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/22/2023] [Accepted: 11/28/2023] [Indexed: 04/04/2024]
Abstract
STUDY OBJECTIVES Automatic sleep staging based on cardiorespiratory signals from home sleep monitoring devices holds great clinical potential. Using state-of-the-art machine learning, promising performance has been reached in patients with sleep disorders. However, it is unknown whether performance would hold in individuals with potentially altered autonomic physiology, for example under the influence of medication. Here, we assess an existing sleep staging algorithm in patients with sleep disorders with and without the use of beta blockers. METHODS We analyzed a retrospective dataset of sleep recordings of 57 patients with sleep disorders using beta blockers and 57 age-matched patients with sleep disorders not using beta blockers. Sleep stages were automatically scored based on electrocardiography and respiratory effort from a thoracic belt, using a previously developed machine-learning algorithm (CReSS algorithm). For both patient groups, sleep stages classified by the model were compared to gold standard manual polysomnography scoring using epoch-by-epoch agreement. Additionally, for both groups, overall sleep parameters were calculated and compared between the two scoring methods. RESULTS Substantial agreement was achieved for four-class sleep staging in both patient groups (beta blockers: kappa = 0.635, accuracy = 78.1%; controls: kappa = 0.660, accuracy = 78.8%). No statistical difference in epoch-by-epoch agreement was found between the two groups. Additionally, the groups did not differ on agreement of derived sleep parameters. CONCLUSIONS We showed that the performance of the CReSS algorithm is not deteriorated in patients using beta blockers. Results do not indicate a fundamental limitation in leveraging autonomic characteristics to obtain a surrogate measure of sleep in this clinically relevant population. CITATION Hermans L, van Meulen F, Anderer P, et al. Performance of cardiorespiratory-based sleep staging in patients using beta blockers. J Clin Sleep Med. 2024;20(4):575-581.
Collapse
Affiliation(s)
- Lieke Hermans
- Philips Research, Eindhoven, The Netherlands
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
| | - Fokke van Meulen
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Peter Anderer
- Philips Sleep and Respiratory Care, Vienna, Austria
- The Siesta Group Schlafanalyse GmbH, Vienna, Austria
| | - Marco Ross
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
- Philips Sleep and Respiratory Care, Vienna, Austria
- The Siesta Group Schlafanalyse GmbH, Vienna, Austria
| | | | - Merel van Gilst
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Pedro Fonseca
- Philips Research, Eindhoven, The Netherlands
- Department of Electrical Engineering, TU/e Eindhoven, Eindhoven, The Netherlands
| |
Collapse
|
19
|
Wang Y, Zhou J, Zha F, Zhou M, Li D, Zheng Q, Chen S, Yan S, Geng X, Long J, Wan L, Wang Y. Comparative analysis of sleep parameters and structures derived from wearable flexible electrode sleep patches and polysomnography in young adults. J Neurophysiol 2024; 131:738-749. [PMID: 38383290 DOI: 10.1152/jn.00465.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 02/13/2024] [Accepted: 02/21/2024] [Indexed: 02/23/2024] Open
Abstract
Polysomnography (PSG) is the gold standard for clinical sleep monitoring, but its cost, discomfort, and limited suitability for continuous use present challenges. The flexible electrode sleep patch (FESP) emerges as an economically viable and patient-friendly solution, offering lightweight, simple operation, and self-applicable. Nevertheless, its utilization in young individuals remains uncertain. The objective of this study was to compare sleep data obtained by FESP and PSG in healthy young individuals and analyze agreement for sleep parameters and structure classification. Overnight monitoring with FESP and PSG recordings in 48 participants (mean age: 23 yr) was done. Correlation analysis, Bland-Altman plots, and Cohen's kappa coefficient assessed consistency. Sensitivity, specificity, and predictive values compared classification against PSG. FESP showed strong correlation and consistency with PSG for sleep monitoring. Bland-Altman plots indicated small errors and high consistency. Kappa values (0.70-0.84) suggested substantial agreement for sleep stage classification. Pearson correlation coefficient values for sleep stages (0.75-0.88) and sleep parameters (0.80-0.96) confirm that FESP has a strong application. Intraclass correlation coefficient yielded values between 0.65 and 0.97. In addition, FESP demonstrated an impressive accuracy range of 84.12-93.47% for sleep stage classification. The FESP also features a wearable self-test program with an error rate of no more than 8% for both deep sleep and wake. In young adults, FESP demonstrated reliable monitoring capabilities comparable to PSG. With its low cost and user-friendly design, FESP is a potential alternative for portable sleep assessment in clinical and research applications. Further studies involving larger populations are needed to validate its diagnostic potential.NEW & NOTEWORTHY By comparison with PSG, this study confirmed the reliability of an efficient, objective, low-cost, and noninvasive portable automatic sleep-monitoring device FESP, which provides effective information for long-term family sleep disorder diagnosis and sleep quality monitoring.
Collapse
Affiliation(s)
- Yuqi Wang
- Rehabilitation Medical College, Shandong University of Traditional Chinese Medicine, Jinan, China
| | - Jing Zhou
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| | - Fubing Zha
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| | - Mingchao Zhou
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| | - Dongxia Li
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| | - Qian Zheng
- College of Computer Science and Control Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Shugeng Chen
- Huashan Hospital, Fudan University, Shanghai, China
| | - Shuiping Yan
- Shenzhen Flexolink Technology Co., Ltd, Shenzhen, China
| | - Xinling Geng
- School of Biomedical Engineering, Capital Medical University, Beijing, China
| | - Jianjun Long
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| | - Li Wan
- Shenzhen Flexolink Technology Co., Ltd, Shenzhen, China
| | - Yulong Wang
- Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Shenzhen, China
| |
Collapse
|
20
|
Parent AA, Guadagni V, Rawling JM, Poulin MJ. Performance Evaluation of a New Sport Watch in Sleep Tracking: A Comparison against Overnight Polysomnography in Young Adults. SENSORS (BASEL, SWITZERLAND) 2024; 24:2218. [PMID: 38610432 PMCID: PMC11014025 DOI: 10.3390/s24072218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 02/23/2024] [Accepted: 03/28/2024] [Indexed: 04/14/2024]
Abstract
Introduction: This study aimed to validate the ability of a prototype sport watch (Polar Electro Oy, FI) to recognize wake and sleep states in two trials with and without an interval training session (IT) 6 h prior to bedtime. Methods: Thirty-six participants completed this study. Participants performed a maximal aerobic test and three polysomnography (PSG) assessments. The first night served as a device familiarization night and to screen for sleep apnea. The second and third in-home PSG assessments were counterbalanced with/without IT. Accuracy and agreement in detecting sleep stages were calculated between PSG and the prototype. Results: Accuracy for the different sleep stages (REM, N1 and N2, N3, and awake) as a true positive for the nights without exercise was 84 ± 5%, 64 ± 6%, 81 ± 6%, and 91 ± 6%, respectively, and for the nights with exercise was 83 ± 7%, 63 ± 8%, 80 ± 7%, and 92 ± 6%, respectively. The agreement for the sleep night without exercise was 60.1 ± 8.1%, k = 0.39 ± 0.1, and with exercise was 59.2 ± 9.8%, k = 0.36 ± 0.1. No significant differences were observed between nights or between the sexes. Conclusion: The prototype showed better or similar accuracy and agreement to wrist-worn consumer products on the market for the detection of sleep stages with healthy adults. However, further investigations will need to be conducted with other populations.
Collapse
Affiliation(s)
- Andrée-Anne Parent
- Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.-A.P.); (V.G.)
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
- Libin Cardiovascular Institute of Alberta, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Veronica Guadagni
- Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.-A.P.); (V.G.)
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Jean M. Rawling
- Department of Family Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada;
| | - Marc J. Poulin
- Department of Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.-A.P.); (V.G.)
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
- Libin Cardiovascular Institute of Alberta, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
- Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada
- O’Brien Institute of Public Health, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada
| |
Collapse
|
21
|
Schyvens AM, Van Oost NC, Aerts JM, Masci F, Peters B, Neven A, Dirix H, Wets G, Ross V, Verbraecken J. Accuracy of Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP Versus Polysomnography: Systematic Review. JMIR Mhealth Uhealth 2024; 12:e52192. [PMID: 38557808 PMCID: PMC11004611 DOI: 10.2196/52192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 02/01/2024] [Accepted: 02/01/2024] [Indexed: 04/04/2024] Open
Abstract
Background Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern. Objective A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages. Methods Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings. Results The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (-1.4 min), light sleep (-9.6 min), and deep sleep (-9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP. Conclusions The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.
Collapse
Affiliation(s)
- An-Marie Schyvens
- Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Edegem, Belgium
- Laboratory of Experimental Medicine and Pediatrics, University of Antwerp, Wilrijk, Belgium
| | | | | | | | - Brent Peters
- Transportation Research Institute (IMOB), School of Transportation Sciences, UHasselt, Hasselt, Belgium
| | - An Neven
- Transportation Research Institute (IMOB), School of Transportation Sciences, UHasselt, Hasselt, Belgium
| | - Hélène Dirix
- Transportation Research Institute (IMOB), School of Transportation Sciences, UHasselt, Hasselt, Belgium
| | - Geert Wets
- Transportation Research Institute (IMOB), School of Transportation Sciences, UHasselt, Hasselt, Belgium
| | - Veerle Ross
- Transportation Research Institute (IMOB), School of Transportation Sciences, UHasselt, Hasselt, Belgium
- Faresa, Evidence-Based Psychological Centre, Hasselt, Belgium
| | - Johan Verbraecken
- Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Edegem, Belgium
- Laboratory of Experimental Medicine and Pediatrics, University of Antwerp, Wilrijk, Belgium
| |
Collapse
|
22
|
van der Woerd C, van Gorp H, Dujardin S, Sastry M, Garcia Caballero H, van Meulen F, van den Elzen S, Overeem S, Fonseca P. Studying sleep: towards the identification of hypnogram features that drive expert interpretation. Sleep 2024; 47:zsad306. [PMID: 38038673 DOI: 10.1093/sleep/zsad306] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 10/18/2023] [Indexed: 12/02/2023] Open
Abstract
STUDY OBJECTIVES Hypnograms contain a wealth of information and play an important role in sleep medicine. However, interpretation of the hypnogram is a difficult task and requires domain knowledge and "clinical intuition." This study aimed to uncover which features of the hypnogram drive interpretation by physicians. In other words, make explicit which features physicians implicitly look for in hypnograms. METHODS Three sleep experts evaluated up to 612 hypnograms, indicating normal or abnormal sleep structure and suspicion of disorders. ElasticNet and convolutional neural network classification models were trained to predict the collected expert evaluations using hypnogram features and stages as input. The models were evaluated using several measures, including accuracy, Cohen's kappa, Matthew's correlation coefficient, and confusion matrices. Finally, model coefficients and visual analytics techniques were used to interpret the models to associate hypnogram features with expert evaluation. RESULTS Agreement between models and experts (Kappa between 0.47 and 0.52) is similar to agreement between experts (Kappa between 0.38 and 0.50). Sleep fragmentation, measured by transitions between sleep stages per hour, and sleep stage distribution were identified as important predictors for expert interpretation. CONCLUSIONS By comparing hypnograms not solely on an epoch-by-epoch basis, but also on these more specific features that are relevant for the evaluation of experts, performance assessment of (automatic) sleep-staging and surrogate sleep trackers may be improved. In particular, sleep fragmentation is a feature that deserves more attention as it is often not included in the PSG report, and existing (wearable) sleep trackers have shown relatively poor performance in this aspect.
Collapse
Affiliation(s)
- Caspar van der Woerd
- Department Mathematics and Computer Science, Eindhoven University of Technology
- Remote Patient Management and Chronic Care, Philips Research, Eindhoven, The Netherlands
| | - Hans van Gorp
- Remote Patient Management and Chronic Care, Philips Research, Eindhoven, The Netherlands
- Department Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | | | | | | | - Fokke van Meulen
- Department Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center, Kempenhaeghe, Heeze, The Netherlands
| | - Stef van den Elzen
- Department Mathematics and Computer Science, Eindhoven University of Technology
| | - Sebastiaan Overeem
- Department Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center, Kempenhaeghe, Heeze, The Netherlands
| | - Pedro Fonseca
- Remote Patient Management and Chronic Care, Philips Research, Eindhoven, The Netherlands
- Department Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
23
|
Irrera F, Gumiero A, Zampogna A, Boscari F, Avogaro A, Gazzanti Pugliese di Cotrone MA, Patera M, Della Torre L, Picozzi N, Suppa A. Multisensor Integrated Platform Based on MEMS Charge Variation Sensing Technology for Biopotential Acquisition. SENSORS (BASEL, SWITZERLAND) 2024; 24:1554. [PMID: 38475089 DOI: 10.3390/s24051554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/25/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024]
Abstract
We propose a new methodology for long-term biopotential recording based on an MEMS multisensor integrated platform featuring a commercial electrostatic charge-transfer sensor. This family of sensors was originally intended for presence tracking in the automotive industry, so the existing setup was engineered for the acquisition of electrocardiograms, electroencephalograms, electrooculograms, and electromyography, designing a dedicated front-end and writing proper firmware for the specific application. Systematic tests on controls and nocturnal acquisitions from patients in a domestic environment will be discussed in detail. The excellent results indicate that this technology can provide a low-power, unexplored solution to biopotential acquisition. The technological breakthrough is in that it enables adding this type of functionality to existing MEMS boards at near-zero additional power consumption. For these reasons, it opens up additional possibilities for wearable sensors and strengthens the role of MEMS technology in medical wearables for the long-term synchronous acquisition of a wide range of signals.
Collapse
Affiliation(s)
- Fernanda Irrera
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00185 Rome, Italy
| | | | - Alessandro Zampogna
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
| | | | - Angelo Avogaro
- Department of Medicine, University of Padua, 35122 Padua, Italy
| | | | - Martina Patera
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
| | | | | | - Antonio Suppa
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
- IRCCS Neuromed, 86077 Pozzilli, Italy
| |
Collapse
|
24
|
Menghini L, Balducci C, de Zambotti M. Is it Time to Include Wearable Sleep Trackers in the Applied Psychologists' Toolbox? THE SPANISH JOURNAL OF PSYCHOLOGY 2024; 27:e8. [PMID: 38410074 DOI: 10.1017/sjp.2024.8] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Wearable sleep trackers are increasingly used in applied psychology. Particularly, the recent boom in the fitness tracking industry has resulted in a number of relatively inexpensive consumer-oriented devices that further enlarge the potential applications of ambulatory sleep monitoring. While being largely positioned as wellness tools, wearable sleep trackers could be considered useful health devices supported by a growing number of independent peer-reviewed studies evaluating their accuracy. The inclusion of sensors that monitor cardiorespiratory physiology, diurnal activity data, and other environmental signals allows for a comprehensive and multidimensional approach to sleep health and its impact on psychological well-being. Moreover, the increasingly common combination of wearable trackers and experience sampling methods has the potential to uncover within-individual processes linking sleep to daily experiences, behaviors, and other psychosocial factors. Here, we provide a concise overview of the state-of-the-art, challenges, and opportunities of using wearable sleep-tracking technology in applied psychology. Specifically, we review key device profiles, capabilities, and limitations. By providing representative examples, we highlight how scholars and practitioners can fully exploit the potential of wearable sleep trackers while being aware of the most critical pitfalls characterizing these devices. Overall, consumer wearable sleep trackers are increasingly recognized as a valuable method to investigate, assess, and improve sleep health. Incorporating such devices in research and professional practice might significantly improve the quantity and quality of the collected information while opening the possibility of involving large samples over representative time periods. However, a rigorous and informed approach to their use is necessary.
Collapse
Affiliation(s)
- Luca Menghini
- Università di Trento (Italy)
- Università degli Studi di Padova (Italy)
| | | | | |
Collapse
|
25
|
Nam B, Bark B, Lee J, Kim IY. InsightSleepNet: the interpretable and uncertainty-aware deep learning network for sleep staging using continuous Photoplethysmography. BMC Med Inform Decis Mak 2024; 24:50. [PMID: 38355559 PMCID: PMC10865603 DOI: 10.1186/s12911-024-02437-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/23/2024] [Indexed: 02/16/2024] Open
Abstract
BACKGROUND This study was conducted to address the existing drawbacks of inconvenience and high costs associated with sleep monitoring. In this research, we performed sleep staging using continuous photoplethysmography (PPG) signals for sleep monitoring with wearable devices. Furthermore, our aim was to develop a more efficient sleep monitoring method by considering both the interpretability and uncertainty of the model's prediction results, with the goal of providing support to medical professionals in their decision-making process. METHOD The developed 4-class sleep staging model based on continuous PPG data incorporates several key components: a local attention module, an InceptionTime module, a time-distributed dense layer, a temporal convolutional network (TCN), and a 1D convolutional network (CNN). This model prioritizes both interpretability and uncertainty estimation in its prediction results. The local attention module is introduced to provide insights into the impact of each epoch within the continuous PPG data. It achieves this by leveraging the TCN structure. To quantify the uncertainty of prediction results and facilitate selective predictions, an energy score estimation is employed. By enhancing both the performance and interpretability of the model and taking into consideration the reliability of its predictions, we developed the InsightSleepNet for accurate sleep staging. RESULT InsightSleepNet was evaluated using three distinct datasets: MESA, CFS, and CAP. Initially, we assessed the model's classification performance both before and after applying an energy score threshold. We observed a significant improvement in the model's performance with the implementation of the energy score threshold. On the MESA dataset, prior to applying the energy score threshold, the accuracy was 84.2% with a Cohen's kappa of 0.742 and weighted F1 score of 0.842. After implementing the energy score threshold, the accuracy increased to a range of 84.8-86.1%, Cohen's kappa values ranged from 0.75 to 0.78 and weighted F1 scores ranged from 0.848 to 0.861. In the case of the CFS dataset, we also noted enhanced performance. Before the application of the energy score threshold, the accuracy stood at 80.6% with a Cohen's kappa of 0.72 and weighted F1 score of 0.808. After thresholding, the accuracy improved to a range of 81.9-85.6%, Cohen's kappa values ranged from 0.74 to 0.79 and weighted F1 scores ranged from 0.821 to 0.857. Similarly, on the CAP dataset, the initial accuracy was 80.6%, accompanied by a Cohen's kappa of 0.73 and weighted F1 score was 0.805. Following the application of the threshold, the accuracy increased to a range of 81.4-84.3%, Cohen's kappa values ranged from 0.74 to 0.79 and weighted F1 scores ranged from 0.813 to 0.842. Additionally, by interpreting the model's predictions, we obtained results indicating a correlation between the peak of the PPG signal and sleep stage classification. CONCLUSION InsightSleepNet is a 4-class sleep staging model that utilizes continuous PPG data, serves the purpose of continuous sleep monitoring with wearable devices. Beyond its primary function, it might facilitate in-depth sleep analysis by medical professionals and empower them with interpretability for intervention-based predictions. This capability can also support well-informed clinical decision-making, providing valuable insights and serving as a reliable second opinion in medical settings.
Collapse
Affiliation(s)
- Borum Nam
- Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
| | - Beomjun Bark
- Department of Biomedical Engineering, Hanyang University, 222, Wangsimni-ro, Seoul, 04763, Republic of Korea
| | - Jeyeon Lee
- Department of Biomedical Engineering, Hanyang University, 222, Wangsimni-ro, Seoul, 04763, Republic of Korea
| | - In Young Kim
- Department of Biomedical Engineering, Hanyang University, 222, Wangsimni-ro, Seoul, 04763, Republic of Korea.
| |
Collapse
|
26
|
Bester M, Almario Escorcia MJ, Fonseca P, Mollura M, van Gilst MM, Barbieri R, Mischi M, van Laar JOEH, Vullings R, Joshi R. The impact of healthy pregnancy on features of heart rate variability and pulse wave morphology derived from wrist-worn photoplethysmography. Sci Rep 2023; 13:21100. [PMID: 38036597 PMCID: PMC10689737 DOI: 10.1038/s41598-023-47980-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 11/20/2023] [Indexed: 12/02/2023] Open
Abstract
Due to the association between dysfunctional maternal autonomic regulation and pregnancy complications, tracking non-invasive features of autonomic regulation derived from wrist-worn photoplethysmography (PPG) measurements may allow for the early detection of deteriorations in maternal health. However, even though a plethora of these features-specifically, features describing heart rate variability (HRV) and the morphology of the PPG waveform (morphological features)-exist in the literature, it is unclear which of these may be valuable for tracking maternal health. As an initial step towards clarity, we compute comprehensive sets of HRV and morphological features from nighttime PPG measurements. From these, using logistic regression and stepwise forward feature elimination, we identify the features that best differentiate healthy pregnant women from non-pregnant women, since these likely capture physiological adaptations necessary for sustaining healthy pregnancy. Overall, morphological features were more valuable for discriminating between pregnant and non-pregnant women than HRV features (area under the receiver operating characteristics curve of 0.825 and 0.74, respectively), with the systolic pulse wave deterioration being the most valuable single feature, followed by mean heart rate (HR). Additionally, we stratified the analysis by sleep stages and found that using features calculated only from periods of deep sleep enhanced the differences between the two groups. In conclusion, we postulate that in addition to HRV features, morphological features may also be useful in tracking maternal health and suggest specific features to be included in future research concerning maternal health.
Collapse
Affiliation(s)
- M Bester
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
- Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands.
| | - M J Almario Escorcia
- Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy
| | - P Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands
| | - M Mollura
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy
| | - M M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE, Heeze, The Netherlands
| | - R Barbieri
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, MI, Italy
| | - M Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
| | - J O E H van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, De Run 4600, 5504 DB, Veldhoven, The Netherlands
| | - R Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
| | - R Joshi
- Patient Care and Monitoring, Philips Research, 5656 AE, Eindhoven, The Netherlands
| |
Collapse
|
27
|
Charlton PH, Allen J, Bailón R, Baker S, Behar JA, Chen F, Clifford GD, Clifton DA, Davies HJ, Ding C, Ding X, Dunn J, Elgendi M, Ferdoushi M, Franklin D, Gil E, Hassan MF, Hernesniemi J, Hu X, Ji N, Khan Y, Kontaxis S, Korhonen I, Kyriacou PA, Laguna P, Lázaro J, Lee C, Levy J, Li Y, Liu C, Liu J, Lu L, Mandic DP, Marozas V, Mejía-Mejía E, Mukkamala R, Nitzan M, Pereira T, Poon CCY, Ramella-Roman JC, Saarinen H, Shandhi MMH, Shin H, Stansby G, Tamura T, Vehkaoja A, Wang WK, Zhang YT, Zhao N, Zheng D, Zhu T. The 2023 wearable photoplethysmography roadmap. Physiol Meas 2023; 44:111001. [PMID: 37494945 PMCID: PMC10686289 DOI: 10.1088/1361-6579/acead2] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 04/04/2023] [Accepted: 07/26/2023] [Indexed: 07/28/2023]
Abstract
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.
Collapse
Affiliation(s)
- Peter H Charlton
- Department of Public Health and Primary Care, University of Cambridge, Cambridge, CB1 8RN, United Kingdom
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - John Allen
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
| | - Raquel Bailón
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Stephanie Baker
- College of Science and Engineering, James Cook University, Cairns, 4878 Queensland, Australia
| | - Joachim A Behar
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, 518055 Guandong, People’s Republic of China
| | - Gari D Clifford
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30322, United States of America
- Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
| | - David A Clifton
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Harry J Davies
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Cheng Ding
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America
- Department of Biomedical Engineering, Emory University, Atlanta, GA 30322, United States of America
| | - Xiaorong Ding
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, People’s Republic of China
| | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
- Department of Biostatistics & Bioinformatics, Duke University, Durham, NC 27708-0187, United States of America
- Duke Clinical Research Institute, Durham, NC 27705-3976, United States of America
| | - Mohamed Elgendi
- Biomedical and Mobile Health Technology Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland
| | - Munia Ferdoushi
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Daniel Franklin
- Institute of Biomedical Engineering, Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, University of Toronto, Toronto, M5G 1M1, Canada
| | - Eduardo Gil
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Md Farhad Hassan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Jussi Hernesniemi
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Xiao Hu
- Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Biomedical Informatics, School of Medicine, Emory University, Atlanta, 30322, Georgia, United States of America
- Department of Computer Sciences, College of Arts and Sciences, Emory University, Atlanta, GA 30322, United States of America
| | - Nan Ji
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
| | - Yasser Khan
- Department of Electrical and Computer Engineering, University of Southern California, 90089, Los Angeles, California, United States of America
- The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, United States of America
| | - Spyridon Kontaxis
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Ilkka Korhonen
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
| | - Panicos A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Pablo Laguna
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Jesús Lázaro
- Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Aragon Institute of Engineering Research (I3A), IIS Aragon, University of Zaragoza, E-50018 Zaragoza, Spain
- CIBER-BBN, Instituto de Salud Carlos III, C/Monforte de Lemos 3-5, E-28029 Madrid, Spain
| | - Chungkeun Lee
- Digital Health Devices Division, Medical Device Evaluation Department, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju, 28159, Republic of Korea
| | - Jeremy Levy
- Faculty of Biomedical Engineering, Technion Israel Institute of Technology, Haifa, 3200003, Israel
- Faculty of Electrical and Computer Engineering, Technion Institute of Technology, Haifa, 3200003, Israel
| | - Yumin Li
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Chengyu Liu
- State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, People’s Republic of China
| | - Jing Liu
- Analog Devices Inc, San Jose, CA 95124, United States of America
| | - Lei Lu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| | - Danilo P Mandic
- Department of Electrical and Electronic Engineering, Imperial College London, London, SW7 2AZ, United Kingdom
| | - Vaidotas Marozas
- Department of Electronics Engineering, Kaunas University of Technology, 44249 Kaunas, Lithuania
- Biomedical Engineering Institute, Kaunas University of Technology, 44249 Kaunas, Lithuania
| | - Elisa Mejía-Mejía
- Research Centre for Biomedical Engineering, City, University of London, London, EC1V 0HB, United Kingdom
| | - Ramakrishna Mukkamala
- Department of Bioengineering and Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Meir Nitzan
- Department of Physics/Electro-Optic Engineering, Lev Academic Center, 91160 Jerusalem, Israel
| | - Tania Pereira
- INESC TEC—Institute for Systems and Computer Engineering, Technology and Science, Porto, 4200-465, Portugal
- Faculty of Engineering, University of Porto, Porto, 4200-465, Portugal
| | | | - Jessica C Ramella-Roman
- Department of Biomedical Engineering and Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33174, United States of America
| | - Harri Saarinen
- Tampere Heart Hospital, Wellbeing Services County of Pirkanmaa, Tampere, 33520, Finland
| | - Md Mobashir Hasan Shandhi
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Hangsik Shin
- Department of Digital Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Gerard Stansby
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, NE2 4HH, United Kingdom
- Northern Vascular Centre, Freeman Hospital, Newcastle upon Tyne, NE7 7DN, United Kingdom
| | - Toshiyo Tamura
- Future Robotics Organization, Waseda University, Tokyo, 1698050, Japan
| | - Antti Vehkaoja
- Finnish Cardiovascular Research Center Tampere, Faculty of Medicine and Health Technology, Tampere University, Tampere, 33720, Finland
- PulseOn Ltd, Espoo, 02150, Finland
| | - Will Ke Wang
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0187, United States of America
| | - Yuan-Ting Zhang
- Hong Kong Center for Cerebrocardiovascular Health Engineering (COCHE), Hong Kong Science and Technology Park, Hong Kong, 999077, People’s Republic of China
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, People’s Republic of China
| | - Ni Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Coventry University, Coventry, CV1 5RW, United Kingdom
| | - Tingting Zhu
- Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom
| |
Collapse
|
28
|
van Gorp H, van Gilst MM, Fonseca P, Overeem S, van Sloun RJG. Modeling the Impact of Inter-Rater Disagreement on Sleep Statistics Using Deep Generative Learning. IEEE J Biomed Health Inform 2023; 27:5599-5609. [PMID: 37561616 DOI: 10.1109/jbhi.2023.3304010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
Sleep staging is the process by which an overnight polysomnographic measurement is segmented into epochs of 30 seconds, each of which is annotated as belonging to one of five discrete sleep stages. The resulting scoring is graphically depicted as a hypnogram, and several overnight sleep statistics are derived, such as total sleep time and sleep onset latency. Gold standard sleep staging as performed by human technicians is time-consuming, costly, and comes with imperfect inter-scorer agreement, which also results in inter-scorer disagreement about the overnight statistics. Deep learning algorithms have shown promise in automating sleep scoring, but struggle to model inter-scorer disagreement in sleep statistics. To that end, we introduce a novel technique using conditional generative models based on Normalizing Flows that permits the modeling of the inter-rater disagreement of overnight sleep statistics, termed U-Flow. We compare U-Flow to other automatic scoring methods on a hold-out test set of 70 subjects, each scored by six independent scorers. The proposed method achieves similar sleep staging performance in terms of accuracy and Cohen's kappa on the majority-voted hypnograms. At the same time, U-Flow outperforms the other methods in terms of modeling the inter-rater disagreement of overnight sleep statistics. The consequences of inter-rater disagreement about overnight sleep statistics may be great, and the disagreement potentially carries diagnostic and scientifically relevant information about sleep structure. U-Flow is able to model this disagreement efficiently and can support further investigations into the impact inter-rater disagreement has on sleep medicine and basic sleep research.
Collapse
|
29
|
Bester M, Perciballi G, Fonseca P, van Gilst MM, Mischi M, van Laar JO, Vullings R, Joshi R. Maternal cardiorespiratory coupling: differences between pregnant and nonpregnant women are further amplified by sleep-stage stratification. J Appl Physiol (1985) 2023; 135:1199-1212. [PMID: 37767554 PMCID: PMC10979799 DOI: 10.1152/japplphysiol.00296.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 08/22/2023] [Accepted: 09/22/2023] [Indexed: 09/29/2023] Open
Abstract
Pregnancy complications are associated with abnormal maternal autonomic regulation. Subsequently, thoroughly understanding maternal autonomic regulation during healthy pregnancy may enable the earlier detection of complications, in turn allowing for the improved management thereof. Under healthy autonomic regulation, reciprocal interactions occur between the cardiac and respiratory systems, i.e., cardiorespiratory coupling (CRC). Here, we investigate, for the first time, the differences in CRC between healthy pregnant and nonpregnant women. We apply two algorithms, namely, synchrograms and bivariate phase-rectified signal averaging, to nighttime recordings of ECG and respiratory signals. We find that CRC is present in both groups. Significantly less (P < 0.01) cardiorespiratory synchronization occurs in pregnant women (11% vs. 15% in nonpregnant women). Moreover, there is a smaller response in the heart rate of pregnant women corresponding to respiratory inhalations and exhalations. In addition, we stratified these analyses by sleep stages. As each sleep stage is governed by different autonomic states, this stratification not only amplified some of the differences between groups but also brought out differences that remained hidden when analyzing the full-night recordings. Most notably, the known positive relationship between CRC and deep sleep is less prominent in pregnant women than in their nonpregnant counterparts. The decrease in CRC during healthy pregnancy may be attributable to decreased maternal parasympathetic activity, anatomical changes to the maternal respiratory system, and the increased physiological stress accompanying pregnancy. This work offers novel insight into the physiology of healthy pregnancy and forms part of the base knowledge needed to detect abnormalities in pregnancy.NEW & NOTEWORTHY We compare CRC, i.e., the reciprocal interaction between the cardiac and respiratory systems, between healthy pregnant and nonpregnant women for the first time. Although CRC is present in both groups, CRC is reduced during healthy pregnancy; there is less synchronization between maternal cardiac and respiratory activity and a smaller response in maternal heart rate to respiratory inhalations and exhalations. Stratifying this analysis by sleep stages reveals that differences are most prominent during deep sleep.
Collapse
Affiliation(s)
- Maretha Bester
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Patient Care and Monitoring, Philips Research, Eindhoven, The Netherlands
| | - Giulia Perciballi
- Patient Care and Monitoring, Philips Research, Eindhoven, The Netherlands
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Patient Care and Monitoring, Philips Research, Eindhoven, The Netherlands
| | - Merel M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Judith Oeh van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, Veldhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rohan Joshi
- Patient Care and Monitoring, Philips Research, Eindhoven, The Netherlands
| |
Collapse
|
30
|
de Beukelaar TT, Mantini D. Monitoring Resistance Training in Real Time with Wearable Technology: Current Applications and Future Directions. Bioengineering (Basel) 2023; 10:1085. [PMID: 37760187 PMCID: PMC10525173 DOI: 10.3390/bioengineering10091085] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 08/30/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023] Open
Abstract
Resistance training is an exercise modality that involves using weights or resistance to strengthen and tone muscles. It has become popular in recent years, with numerous people including it in their fitness routines to ameliorate their strength, muscle mass, and overall health. Still, resistance training can be complex, requiring careful planning and execution to avoid injury and achieve satisfactory results. Wearable technology has emerged as a promising tool for resistance training, as it allows monitoring and adjusting training programs in real time. Several wearable devices are currently available, such as smart watches, fitness trackers, and other sensors that can yield detailed physiological and biomechanical information. In resistance training research, this information can be used to assess the effectiveness of training programs and identify areas for improvement. Wearable technology has the potential to revolutionize resistance training research, providing new insights and opportunities for developing optimized training programs. This review examines the types of wearables commonly used in resistance training research, their applications in monitoring and optimizing training programs, and the potential limitations and challenges associated with their use. Finally, it discusses future research directions, including the development of advanced wearable technologies and the integration of artificial intelligence in resistance training research.
Collapse
Affiliation(s)
| | - Dante Mantini
- Movement Control and Neuroplasticity Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium;
| |
Collapse
|
31
|
Abstract
Automatic polysomnography analysis can be leveraged to shorten scoring times, reduce associated costs, and ultimately improve the overall diagnosis of sleep disorders. Multiple and diverse strategies have been attempted for implementation of this technology at scale in the routine workflow of sleep centers. The field, however, is complex and presents unsolved challenges in a number of areas. Recent developments in computer science and artificial intelligence are nevertheless closing the gap. Technological advances are also opening new pathways for expanding our current understanding of the domain and its analysis.
Collapse
Affiliation(s)
- Diego Alvarez-Estevez
- Center for Information and Communications Technology Research (CITIC), Universidade da Coruña, 15071 A Coruña, Spain.
| |
Collapse
|
32
|
Petek BJ, Al-Alusi MA, Moulson N, Grant AJ, Besson C, Guseh JS, Wasfy MM, Gremeaux V, Churchill TW, Baggish AL. Consumer Wearable Health and Fitness Technology in Cardiovascular Medicine: JACC State-of-the-Art Review. J Am Coll Cardiol 2023; 82:245-264. [PMID: 37438010 PMCID: PMC10662962 DOI: 10.1016/j.jacc.2023.04.054] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 04/26/2023] [Accepted: 04/28/2023] [Indexed: 07/14/2023]
Abstract
The use of consumer wearable devices (CWDs) to track health and fitness has rapidly expanded over recent years because of advances in technology. The general population now has the capability to continuously track vital signs, exercise output, and advanced health metrics. Although understanding of basic health metrics may be intuitive (eg, peak heart rate), more complex metrics are derived from proprietary algorithms, differ among device manufacturers, and may not historically be common in clinical practice (eg, peak V˙O2, exercise recovery scores). With the massive expansion of data collected at an individual patient level, careful interpretation is imperative. In this review, we critically analyze common health metrics provided by CWDs, describe common pitfalls in CWD interpretation, provide recommendations for the interpretation of abnormal results, present the utility of CWDs in exercise prescription, examine health disparities and inequities in CWD use and development, and present future directions for research and development.
Collapse
Affiliation(s)
- Bradley J Petek
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA; Knight Cardiovascular Institute, Oregon Health and Science University, Portland, Oregon, USA
| | - Mostafa A Al-Alusi
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Nathaniel Moulson
- Division of Cardiology and Sports Cardiology BC, University of British Columbia, Vancouver, British Columbia, Canada
| | - Aubrey J Grant
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Cyril Besson
- Swiss Olympic Medical Center, Lausanne University Hospital (CHUV), Lausanne, Switzerland; Institute for Sport Science, University of Lausanne (ISSUL), Lausanne, Switzerland
| | - J Sawalla Guseh
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Meagan M Wasfy
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Vincent Gremeaux
- Swiss Olympic Medical Center, Lausanne University Hospital (CHUV), Lausanne, Switzerland; Institute for Sport Science, University of Lausanne (ISSUL), Lausanne, Switzerland
| | - Timothy W Churchill
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Aaron L Baggish
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA; Cardiovascular Performance Program, Massachusetts General Hospital, Boston, Massachusetts, USA; Swiss Olympic Medical Center, Lausanne University Hospital (CHUV), Lausanne, Switzerland; Institute for Sport Science, University of Lausanne (ISSUL), Lausanne, Switzerland.
| |
Collapse
|
33
|
Fonseca P, Ross M, Cerny A, Anderer P, van Meulen F, Janssen H, Pijpers A, Dujardin S, van Hirtum P, van Gilst M, Overeem S. A computationally efficient algorithm for wearable sleep staging in clinical populations. Sci Rep 2023; 13:9182. [PMID: 37280297 PMCID: PMC10244431 DOI: 10.1038/s41598-023-36444-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 06/03/2023] [Indexed: 06/08/2023] Open
Abstract
This study describes a computationally efficient algorithm for 4-class sleep staging based on cardiac activity and body movements. Using an accelerometer to calculate gross body movements and a reflective photoplethysmographic (PPG) sensor to determine interbeat intervals and a corresponding instantaneous heart rate signal, a neural network was trained to classify between wake, combined N1 and N2, N3 and REM sleep in epochs of 30 s. The classifier was validated on a hold-out set by comparing the output against manually scored sleep stages based on polysomnography (PSG). In addition, the execution time was compared with that of a previously developed heart rate variability (HRV) feature-based sleep staging algorithm. With a median epoch-per-epoch κ of 0.638 and accuracy of 77.8% the algorithm achieved an equivalent performance when compared to the previously developed HRV-based approach, but with a 50-times faster execution time. This shows how a neural network, without leveraging any a priori knowledge of the domain, can automatically "discover" a suitable mapping between cardiac activity and body movements, and sleep stages, even in patients with different sleep pathologies. In addition to the high performance, the reduced complexity of the algorithm makes practical implementation feasible, opening up new avenues in sleep diagnostics.
Collapse
Affiliation(s)
- Pedro Fonseca
- Philips Research Eindhoven, High Tech Campus 34, 5656AE, Eindhoven, The Netherlands.
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Marco Ross
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep and Respiratory Care, Philips Austria GmbH, Vienna, Austria
| | - Andreas Cerny
- Sleep and Respiratory Care, Philips Austria GmbH, Vienna, Austria
| | - Peter Anderer
- Sleep and Respiratory Care, Philips Austria GmbH, Vienna, Austria
| | - Fokke van Meulen
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Hennie Janssen
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | | | | | | | - Merel van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands
| |
Collapse
|
34
|
van Meulen FB, Grassi A, van den Heuvel L, Overeem S, van Gilst MM, van Dijk JP, Maass H, van Gastel MJH, Fonseca P. Contactless Camera-Based Sleep Staging: The HealthBed Study. BIOENGINEERING (BASEL, SWITZERLAND) 2023; 10:bioengineering10010109. [PMID: 36671681 PMCID: PMC9855193 DOI: 10.3390/bioengineering10010109] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023]
Abstract
Polysomnography (PSG) remains the gold standard for sleep monitoring but is obtrusive in nature. Advances in camera sensor technology and data analysis techniques enable contactless monitoring of heart rate variability (HRV). In turn, this may allow remote assessment of sleep stages, as different HRV metrics indirectly reflect the expression of sleep stages. We evaluated a camera-based remote photoplethysmography (PPG) setup to perform automated classification of sleep stages in near darkness. Based on the contactless measurement of pulse rate variability, we use a previously developed HRV-based algorithm for 3 and 4-class sleep stage classification. Performance was evaluated on data of 46 healthy participants obtained from simultaneous overnight recording of PSG and camera-based remote PPG. To validate the results and for benchmarking purposes, the same algorithm was used to classify sleep stages based on the corresponding ECG data. Compared to manually scored PSG, the remote PPG-based algorithm achieved moderate agreement on both 3 class (Wake-N1/N2/N3-REM) and 4 class (Wake-N1/N2-N3-REM) classification, with average κ of 0.58 and 0.49 and accuracy of 81% and 68%, respectively. This is in range with other performance metrics reported on sensing technologies for wearable sleep staging, showing the potential of video-based non-contact sleep staging.
Collapse
Affiliation(s)
- Fokke B. van Meulen
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
- Correspondence:
| | - Angela Grassi
- Philips Research, 5656 AE Eindhoven, The Netherlands
| | | | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Merel M. van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Johannes P. van Dijk
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
| | - Henning Maass
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Mark J. H. van Gastel
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Philips Research, 5656 AE Eindhoven, The Netherlands
| |
Collapse
|
35
|
Representations of temporal sleep dynamics: review and synthesis of the literature. Sleep Med Rev 2022; 63:101611. [DOI: 10.1016/j.smrv.2022.101611] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/25/2022] [Accepted: 02/07/2022] [Indexed: 12/13/2022]
|