1
|
Ahmad W, Liang K, Xiong J, Dai J, Cao J, Xia Z. Precision Orthodontic Force Simulation Using Nodal Displacement-Based Archwire Loading Approach. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3889. [PMID: 39538409 DOI: 10.1002/cnm.3889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 07/25/2024] [Accepted: 11/03/2024] [Indexed: 11/16/2024]
Abstract
Precision in force simulationis critical for forecasting tooth movement and optimizing orthodontic treatment strategies. While traditional techniques have provided valuable insights, there remains a need for improved methodologies that can seamlessly integrate with fixed orthodontic practices. This study aims to refine orthodontic force simulation techniques by integrating a nodal displacement approach within finite element analysis, specifically designed to enhance prediction accuracy in tooth movement and optimize orthodontic treatment planning. Three-dimensional patient-specific models of the Tooth, Periodontal Ligament, and Bone Complex (TPBC) of five volunteers were created, along with models of brackets and wires. The simulation involved an initial step of estimating node displacements to align the archwire with the brackets, followed by a subsequent step to attain the required tooth movement and determine the orthodontic force. Experimental validation of the simulation results was performed using an orthodontic force tester (OFT). Utilizing the nodal displacement approach, the simulation successfully positioned the archwire onto the brackets. When benchmarked against the OFT, 80% of the simulated force directions exhibited angular discrepancies of less than 5°. Additionally, the absolute differences in force magnitude reached 20.06 cN, and in moments, up to 71.76 cN mm. The relative differences were as high as 9.55% for force and 13.83% for moments. These findings represent an improvement of up to 10.45% in force accuracy and 8.87% in moment accuracy compared to median values reported in most recent literature. In this research, a nodal displacement methodology was employed to simulate orthodontic forces with precision across the dental arch. The results demonstrate the approache's potential to enhance the accuracy of force prediction in orthodontic treatment planning, thereby advancing our understanding of orthodontic biomechanics.
Collapse
Affiliation(s)
- Waheed Ahmad
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Kanhui Liang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jing Xiong
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Juan Dai
- Department of Dentistry, General Hospital of Shenzhen University, Shenzhen, China
| | - Jun Cao
- Department of Dentistry, General Hospital of Shenzhen University, Shenzhen, China
- Institute of Stomatological Research, Shenzhen University, Shenzhen, China
| | - Zeyang Xia
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Sabbagh H, Haas E, Baumert U, Seidel CL, Hötzel L, Wichelhaus A. Biomechanical Simulation of Orthodontic En-Bloc Retraction Comparing Compound Technique and Sliding Mechanics Using a HOSEA Robotic Device. Bioengineering (Basel) 2024; 11:153. [PMID: 38391639 PMCID: PMC10886252 DOI: 10.3390/bioengineering11020153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024] Open
Abstract
En-bloc retraction is a common procedure in orthodontic therapy. The application of palatal root torque moments is required to control incisor inclination during retraction, yet studies comparing forces and moments with respect to different mechanics are lacking. This study aimed to investigate the forces and moments during orthodontic en-bloc retraction using a robotic biomechanical simulation system, comparing two distinct approaches: (I) compound technique [stainless steel (SS) combined with nickel-titanium (NiTi)] using industrially pretorqued retraction-torque-archwires (RTA) in combination with NiTi closed coil springs; (II) conventional sliding mechanics using SS archwires with manually applied anterior twist bends in combination with elastic chains. Two dimensions (0.017" × 0.025" and 0.018" × 0.025") and ten archwires per group were investigated using 0.022" slot self-ligating brackets. Kruskal-Wallis tests with a significance level of α = 0.05 were conducted. The biomechanical simulation showed that en-bloc retraction was characterized by a series of tipping and uprighting movements, differing significantly regarding the examined mechanics. Collateral forces and moments occurred in all groups. Notably, RTA exhibited fewer extrusive forces. The most bodily movement was achieved with the compound technique and the 0.018" × 0.025" RTA. Sliding mechanics exhibited maximum palatal root torque moments of more than 20 Nmm, exceeding recommended values.
Collapse
Affiliation(s)
- Hisham Sabbagh
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - Ellen Haas
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - Uwe Baumert
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - Corinna Lesley Seidel
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - Linus Hötzel
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - Andrea Wichelhaus
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| |
Collapse
|
3
|
Varghese C, Ramaiah PT, Setty S, Madhusudhan V, Thimmiah MK, Dakshina CK. Evaluation of stress distribution values at the temporomandibular joint and distalization of teeth during en-masse retraction of the mandibular dentition using buccal shelf bone screws: A FEM study. Int Orthod 2023; 21:100747. [PMID: 36907085 DOI: 10.1016/j.ortho.2023.100747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 02/15/2023] [Accepted: 02/17/2023] [Indexed: 03/12/2023]
Abstract
INTRODUCTION Present Finite-element-method (FEM) study evaluates the stress distribution values at the Temporomandibular-Joint (TMJ) during en-masse retraction of the mandibular dentition using buccal shelf bone screws with varying magnitudes of forces. MATERIAL AND METHODS Nine replicas of a pre-existing three-dimensional finite element model of the craniofacial skeleton and articular disc from Cone-Beam-Computed-Tomography (CBCT) data and Magnetic-Resonance-Imaging (MRI) data of a patient were used. Buccal shelf (BS) bone screws were inserted buccal to the mandibular second molar region. Forces of magnitudes 250 gm, 350 gm and 450 gm were applied through NiTi coil springs along with stainless-steel archwires of sizes 0.016 × 0.022-inch, 0.017 × 0.025-inch and 0.019 × 0.025-inch. RESULTS On the articular disc, the maximum stress was observed at the inferior region and the inferior part of the anterior and posterior zone at all force levels. The stress on the articular disc and displacement of teeth increased with increase in force levels in all the 3 archwires. The maximum stress at the articular disc and displacement of teeth was observed for 450 gm force and the least for 250 gm force. No significant difference in the amount of displacement of teeth or the stresses produced at the articular disc was seen with increasing the size of the archwire. CONCLUSION With the present FEM study, we can deduce that it is better to use forces of lower levels on patients with temporomandibular-disorders (TMD) so as to reduce the stresses produced at the TMJ to avoid worsening of the TMD condition.
Collapse
Affiliation(s)
- Cilpa Varghese
- Department of Orthodontics and Dentofacial Orthopedics, Sri-Siddhartha Dental College and Hospital, Sri-Siddhartha Academy of Higher Education, Tumkur, Karnataka, India.
| | - Prasanna T Ramaiah
- Department of Dentistry, Siddaganga Medical College and Research Institute, Tumkur, Karnataka, India
| | - Suhas Setty
- Department of Oral Medicine and Radiology, Siddhartha Dental College and Hospital, Tumkur, Karnataka, India
| | - V Madhusudhan
- Department of Orthodontics and Dentofacial Orthopedics, Sri-Siddhartha Dental College and Hospital, Sri-Siddhartha Academy of Higher Education, Tumkur, Karnataka, India
| | - Manjula K Thimmiah
- Department of Orthodontics and Dentofacial Orthopedics, Sri-Siddhartha Dental College and Hospital, Sri-Siddhartha Academy of Higher Education, Tumkur, Karnataka, India
| | - Chethan K Dakshina
- Department of Orthodontics and Dentofacial Orthopedics, Sri-Siddhartha Dental College and Hospital, Sri-Siddhartha Academy of Higher Education, Tumkur, Karnataka, India
| |
Collapse
|
4
|
Cheng Y, Liu X, Chen X, Li X, Fang S, Wang W, Ma Y, Jin Z. The three-dimensional displacement tendency of teeth depending on incisor torque compensation with clear aligners of different thicknesses in cases of extraction: a finite element study. BMC Oral Health 2022; 22:499. [DOI: 10.1186/s12903-022-02521-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 10/13/2022] [Indexed: 11/17/2022] Open
Abstract
Abstract
Background
Despite the popularity of clear aligner treatment, the effect of the thickness of these aligners has not been fully investigated. The objective of this study was to assess the effects of incisor torque compensation with different thicknesses of clear aligner on the three-dimensional displacement tendency of teeth in cases of extraction.
Methods
Three-dimensional finite element models of the maxillary dentition with extracted first premolars, maxilla, periodontal ligaments, attachments, and aligners were constructed and subject to Finite Element Analysis (FEA). Two groups of models were created: (1) with 0.75 mm-thick aligners and (2) with 0.5 mm-thick aligners. A loading method was developed to simulate the action of clear aligners for the en masse retraction of the incisors. Power ridges of different heights were applied to both groups to mimic torque control, and the power ridges favoring the translation of the central incisors were selected. Then, we used ANSYS software to analyze the initial displacement of teeth and the principle stress on the PDL.
Results
Distal tipping, lingual tipping and extrusion of the incisors, distal tipping and extrusion of the canines, and mesial tipping and intrusion of the posterior teeth were all generated by clear aligner therapy. With the 0.5 mm-thick aligner, a power ridge of 0.7 mm could cause bodily retraction of the central incisors. With the 0.75 mm-thick aligner, a power ridge of 0.25 mm could cause translation of the central incisors. Aligner torque compensation created by the power ridges generated palatal root torque and intrusion of the incisors, intrusion of the canines, mesial tipping and the intrusion of the second premolar; these effects were more significant with a 0.75 mm-thick aligner. After torque compensation, the stress placed on the periodontal ligament of the incisors was distributed more evenly with the 0.75 mm-thick aligner.
Conclusions
The torque compensation caused by power ridges can achieve incisor intrusion and palatal root torque. Appropriate torque compensation with thicker aligners should be designed to ensure bodily retraction of anterior teeth and minimize root resorption, although more attention should be paid to the anchorage control of posterior teeth in cases of extraction.
Collapse
|
5
|
Choi JY, Park JJ, Park KH, Park YG, Park JH. Torque and vertical control of maxillary incisors for an esthetic smile using TSADs implanted in various areas: Biomechanical considerations. Semin Orthod 2022. [DOI: 10.1053/j.sodo.2022.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
6
|
Choi JY, Kim MJ, Kim SH, Chung KR, Nelson G. Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study. SENSORS 2021; 21:s21113798. [PMID: 34070904 PMCID: PMC8198358 DOI: 10.3390/s21113798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 05/26/2021] [Accepted: 05/27/2021] [Indexed: 12/26/2022]
Abstract
The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole considering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position.
Collapse
Affiliation(s)
- Jin-Young Choi
- Department of Orthodontics, Kyung Hee University Dental Hospital, Seoul 02447, Korea;
| | - Min-Jung Kim
- Department of Convergence Medicine, Asan Medical Center, Asan Medical Institute of Convergence Science and 8 Technology, Seoul 02447, Korea;
| | - Seong-Hun Kim
- Department of Orthodontics, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea;
- Correspondence:
| | - Kyu-Rhim Chung
- Department of Orthodontics, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea;
| | - Gerald Nelson
- Division of Orthodontics, Department of Orofacial Science, University of California, San Francisco, CA 94143, USA;
| |
Collapse
|
7
|
Choi JY, Cho J, Oh SH, Kim SH, Chung KR, Nelson G. Effect of Different Surface Designs on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study. SENSORS 2021; 21:s21061964. [PMID: 33799632 PMCID: PMC8001794 DOI: 10.3390/s21061964] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 03/05/2021] [Accepted: 03/08/2021] [Indexed: 01/03/2023]
Abstract
High orthodontic forces and various directions of applied forces can be associated with loosening of the screw anchorage in the bone. Screw designs have been modified to increase the stability of the miniscrews. This research evaluates the influence of three-designs on the stability of orthodontic miniscrews. A conventionally cylinder-type miniscrew design (Bio-Action screw, Jin-Biomed co., Bucheon, Korea) was set as a control, and three conditions were studied based on modifications of this control design. Condition-1 has narrowed threads in the upper part of the screw; Condition-2 has a notch at the middle part; and Condition-3 has the combination of Condition-1 and Condition-2. The moment required to unwind the miniscrew to five degrees is tested, and the moment generated at the cortical bone and the trabecular bone were calculated with finite element analysis. Compared to the control, all three conditions showed a higher moment required to unwind the miniscrew and a higher moment generated at the cortical bone. At the trabecular bone, condition-2 and -3 showed higher moment than the control, and condition-1 showed similar moment to the control. Condition-3 required a higher overall moment to unwind the miniscrew. These findings validate the design modifications used to increase the rotational resistance.
Collapse
Affiliation(s)
- Jin-Young Choi
- Department of Orthodontics, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea; (J.-Y.C.); (K.-R.C.)
| | - Jaehee Cho
- Department of Orthodontics, Graduate School of Medicine, Korea University, Seoul 02841, Korea;
| | - Song Hee Oh
- Department of Oral and Maxillofacial Radiology, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea;
| | - Seong-Hun Kim
- Department of Orthodontics, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea; (J.-Y.C.); (K.-R.C.)
- Correspondence:
| | - Kyu-Rhim Chung
- Department of Orthodontics, Graduate School of Dentistry, Kyung Hee University, Seoul 02447, Korea; (J.-Y.C.); (K.-R.C.)
| | - Gerald Nelson
- Division of Orthodontics, Department of Orofacial Science, University of California, San Francisco, CA 94143, USA;
| |
Collapse
|
8
|
Khanehmasjedi M, Bagheri S, Rakhshan V, Hasani M. Characteristics and Dynamics of Full Arch Distalization Using Transpalatal Arches with Midpalatal and Interradicular Miniscrews as Temporary Anchorage Devices: A Preliminary Finite Element Analysis. Int J Dent 2020; 2020:6648526. [PMID: 33381182 PMCID: PMC7765728 DOI: 10.1155/2020/6648526] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/16/2020] [Accepted: 12/05/2020] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Miniscrews have proved quite effective in fixed orthodontic treatment. They can be placed in areas like palatal interradicular zones or midpalatal suture. Despite the value of these methods and their ever-increasing use, their characteristics are not assessed before when implanted in palatal interradicular areas or in the midpalatal suture. We aimed to assess, for the first time, the dynamics of full arch distalization using such miniscrews. METHODS A 3D model of maxilla with all permanent dentition was created from a CT scan volume. Tissues were segmented and differentiated. Afterward, miniscrews and appliances were designed, and the whole model was registered within a finite element analysis software by assigning proper mechanical properties to tissues and orthodontic appliances. The full arches were distalized using transpalatal arches with miniscrews as anchorage devices (in two different models). The extents of stresses and patterns of movements of various elements (teeth, miniscrews, appliances, tissues) were estimated. Results and Conclusions. Comparing the two models, it is obvious that in both models, the stress distribution is the highest in the TPA arms and the head of the miniscrew where the spring is connected. In comparison with the displacement in the X-axis, the "mesial in" rotation is seen in the first molar of both models. But there is one exception and that is the "mesial out" rotation of the right second molar. In all measurements, the amount of movement in Model 2 (with palatal interradicular miniscrews) is more than that in Model 1 (with midpalatal miniscrew). In the Y-axis, more tipping is seen in Model 2, especially the anterior teeth (detorque) and the first molar, but in Model 1, bodily movement of the first molar is more evident. Along the Z-axis, the mesial intrusion of the first molar and the distal extrusion of this tooth can be seen in both models. Again, the displacement values are higher in the second model (with interradicular miniscrews). In comparison with micromotion and stress distribution of miniscrews, in Model 1, maximum stress and micromotion is observed at the head of the miniscrew where it is attached to the spring. Of course, this amount of micromotion increases over time. The same is true for Model 2, but with a lower micromotion. As for the amount of stress, the stress distribution in both miniscrews of both models is almost uniform and rather severe.
Collapse
Affiliation(s)
- Mashallah Khanehmasjedi
- Dept of Orthodontics, Dental School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Sepideh Bagheri
- Dept of Orthodontics, Dental School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Vahid Rakhshan
- Dept of Anatomy, Dental School, Azad University of Medical Sciences, Tehran, Iran
| | - Mojtaba Hasani
- Mechanical Engineering Department, Iran University of Science and Technology, Tehran, Iran
| |
Collapse
|
9
|
Park KH, Choi JY, Kim KA, Kim SJ, Chung KR, Kim SH. Critical issues concerning biocreative strategy in contemporary temporary skeletal anchorage device orthodontics: A narrative review. Orthod Craniofac Res 2020; 24 Suppl 1:39-47. [PMID: 33237622 DOI: 10.1111/ocr.12444] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 10/29/2020] [Accepted: 11/18/2020] [Indexed: 01/24/2023]
Abstract
Biocreative Orthodontic Strategy (BOS) is designed to establish a physiologically stable occlusion in harmony with masticatory and TMJ function and healthy supporting tissues with strategic use of temporary skeletal anchorage devices (TSADs). This narrative review surveys current research that demonstrates how BOS with TSADs uses a target approach to overcome the limitations experienced with conventional orthodontic treatment. A narrative review article including research on TSADs orthodontics in the permanent dentition. This review is a brief survey of five BOS principles for contemporary TSAD orthodontics: elegant selection of TSADs, bracket prescription to enhance TSAD orthodontics, antero-posterior dimension control, transverse dimension control and airway control issues. Severe malocclusion and craniofacial dysmorphology can be treated with Biocreative Orthodontic Strategy with a minimum number of TSADs. In order to achieve successful treatment outcome using TSADs, it is critical to understand the key diagnosis and treatment principles of BOS and how to develop a target approach for the tooth and bone movement.
Collapse
Affiliation(s)
- Ki-Ho Park
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| | - Jin-Young Choi
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| | - Kyung A Kim
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| | - Su-Jung Kim
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| | - Kyu-Rhim Chung
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| | - Seong-Hun Kim
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, Korea
| |
Collapse
|