1
|
Kury M, Prunes BB, Saraceni CHC, Hilgert LA, Fronza BM, Lima AF. Clinical decision-making in tooth bleaching based on current evidence: A narrative review. Dent Mater 2025; 41:536-552. [PMID: 40082147 DOI: 10.1016/j.dental.2025.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Revised: 02/27/2025] [Accepted: 03/07/2025] [Indexed: 03/16/2025]
Abstract
OBJECTIVE This review consolidates current knowledge on dentist-supervised tooth bleaching for vital teeth, drawing from systematic reviews, meta-analyses, and randomized clinical trials (RCTs) that followed CONSORT guidelines. DATA RESOURCES MeSH and free terms like "tooth bleaching," "tooth whitening," "randomized clinical trial," and "systematic review" were used in PubMed, Scopus, and Web of Science databases STUDY SELECTION: Out of 839 articles, 444 were selected for full-text review, excluding case reports, non-randomized trials, literature reviews and those not directly related to tooth bleaching or RCTs not following CONSORT 2010. The remaining 203 studies were used to compare the dentist-supervised at-home and in-office clinical protocols, assessing factors such as color change, tooth sensitivity, and gingival irritation. In vitro studies were cited to support and explain basic concepts of different clinical decisions CONCLUSIONS: Daily at-home bleaching with 10 % carbamide peroxide or lower-concentration hydrogen peroxide over three to four weeks is effective. In-office bleaching with high-concentration hydrogen peroxide exhibits variations in protocols based on the HP concentration and gel's pH. Emerging technologies like violet LEDs and photobiomodulation with infrared lasers show promise in enhancing efficacy and reducing sensitivity, respectively, though more research is needed. The review underscores the importance of ongoing research into desensitization strategies to manage sensitivity related to bleaching. CLINICAL SIGNIFICANCE Tooth bleaching is central to dental aesthetics, offering a range of options that can challenge clinicians. Adverse effects, particularly sensitivity, highlight the need for practice supported in protocols clinically tested and effective desensitization approaches.
Collapse
Affiliation(s)
- Matheus Kury
- Dental Research Division, Paulista University, Sao Paulo, Brazil, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002 Brazil..
| | - Bianca Bem Prunes
- Dental Research Division, Paulista University, Sao Paulo, Brazil, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002 Brazil.; School of Dental Medicine, Albert Einstein Israelite Hospital, São Paulo, SP, Brazil.
| | - Cintia Helena C Saraceni
- Dental Research Division, Paulista University, Sao Paulo, Brazil, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002 Brazil..
| | - Leandro Augusto Hilgert
- School of Health Sciences, Department of Dentistry, University of Brasília, Brasília, Brazil.
| | - Bruna M Fronza
- Dental Research Division, Paulista University, Sao Paulo, Brazil, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002 Brazil.; School of Dental Medicine, Albert Einstein Israelite Hospital, São Paulo, SP, Brazil.
| | - Adriano F Lima
- Dental Research Division, Paulista University, Sao Paulo, Brazil, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002 Brazil..
| |
Collapse
|
2
|
Castro GG, Pinto PA, Favoreto MW, Reis A, Viviana-Mora M, de Miranda RDCM, Cardenas AFM, Loguercio AD, Tavarez RRDJ. Bleaching efficacy of in-office bleaching with violet light using low-concentration hydrogen peroxide nanoparticulate photocatalyst gel: A randomized controlled trial. Photodiagnosis Photodyn Ther 2024; 50:104410. [PMID: 39586392 DOI: 10.1016/j.pdpdt.2024.104410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2024] [Revised: 10/21/2024] [Accepted: 11/20/2024] [Indexed: 11/27/2024]
Abstract
OBJECTIVE This randomized controlled trial aimed to evaluate the bleaching efficacy and tooth sensitivity (TS) of participants submitted to different application protocols of in-office bleaching with violet light using 6 % hydrogen peroxide (HP) nanoparticulate photocatalyst gel. MATERIALS AND METHODS Sixty-six participants were randomized and bleached using either a 6 % HP (Nano White, DMC), and/or violet light (Bright Max Whitening, MMOptics), according to the following protocols: 1) only violet light (VIOL); 2) only bleaching gel application (BG) and; 3) combined bleaching gel application + violet light (BG+VIOL). The bleaching efficacy was evaluated with the Vita Easyshade spectrophotometer, Vita Classical and Vita Bleachedguide scales. The risk and intensity of TS were recorded using a 0-10 visual analogue scale (VAS) and a 0-4 numerical scale (NRS). Color change and intensity of TS values were compared using one-way ANOVA and Tukey's test were used. The absolute risk of TS was compared using the Chi-square test (α = 0.05). RESULTS A significant and higher degree of bleaching was observed in the BG and BG+VIOL groups compared to the VIOL group (p < 0.003). Despite no significant differences in the risk (p > 0.07) and intensity (p > 0.28) of TS among groups, a higher risk of TS was observed in the BG and BG+VIOL groups. CONCLUSIONS Using VIOL reduced the risk of TS but did not improve bleaching. However, BG+VIOL with low-concentration HP nanoparticulate photocatalyst gel achieved equal efficacy and was less likely to cause TS compared to BG.
Collapse
Affiliation(s)
| | | | - Michael Willian Favoreto
- Department of Restorative Dentistry, State University of Ponta Grossa, Parana, Brazil; School of Dentistry, Tuiuti University, Curitiba, Paraná, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, State University of Ponta Grossa, Parana, Brazil
| | - Maria Viviana-Mora
- Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito, Ecuador
| | | | | | - Alessandro D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Parana, Brazil; Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito, Ecuador.
| | | |
Collapse
|
3
|
Bin Hassan SA. Tooth Sensitivity Following Hydrogen Peroxide Bleaching With and Without Ozone: A Randomized Controlled Trial: Tooth Sensitivity Following H 2O 2 Versus H 2O 2/Ozone Bleaching. Pain Res Manag 2024; 2024:2695533. [PMID: 39512891 PMCID: PMC11540894 DOI: 10.1155/2024/2695533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 09/16/2024] [Accepted: 10/16/2024] [Indexed: 11/15/2024]
Abstract
Aims: The aim of this investigation was to assess bleaching sensitivity following bleaching using either 38% H2O2 only or 38% H2O2 followed by ozone application. Methods: In this randomized controlled clinical investigation, 80 participants (40 females and 40 males) were randomly assigned to two groups (n = 40 each; 20 females and 20 males). The upper anterior teeth were bleached by 38% H2O2 for 20 min followed by ozone application for 60 s (healOzone X4, KaVo Dental, Biberach, Germany) in Group 1 (test group). Meanwhile, the bleaching protocol in Group 2 (controls) included the application of just 38% H2O2 for 20 min. Tooth sensitivity before and after bleaching was reported by the participants using a visual analog scale (VAS) from 0 to 10. Mann-Whitney U test, Wilcoxon signed-rank test, and regression analysis were used to analyze the data. Significant statistical outcomes were identified at p < 0.05. Results: Bleaching sensitivity was reported following both tested bleaching protocols (p < 0.001). However, less bleaching sensitivity was reported when ozone was applied for 60 s after bleaching with 38% H2O2 (p < 0.001). Female participants reported more bleaching sensitivity regardless the applied bleaching protocol (p < 0.05). Conclusions: Bleaching protocols with 38% hydrogen peroxide were associated with less bleaching sensitivity when followed by ozone application on the teeth.
Collapse
Affiliation(s)
- Saeed Awod Bin Hassan
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
4
|
Vardasca IS, Favoreto MW, de Araujo Regis M, de Souza Carneiro T, Hul EA, Borges CPF, Reis A, Loguercio AD, Francci C. Low and high hydrogen peroxide concentrations of in-office dental bleaching associated with violet light: an in vitro study. Clin Oral Investig 2024; 28:171. [PMID: 38400920 DOI: 10.1007/s00784-024-05549-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 02/07/2024] [Indexed: 02/26/2024]
Abstract
OBJECTIVES This study aims to assess hydrogen peroxide (HP) penetration within the pulp chamber, color change (CC), physical-chemical properties, and temperature using in-office different concentration bleaching gels with or without violet light. MATERIALS AND METHODS Fifty teeth were divided into five groups (n = 10) based on the HP concentration bleaching gels used (6% and 35%) and the used violet light (with or without). HP penetration within the pulp chamber was measured using UV-Vis. The CC was evaluated with a digital spectrophotometer. Initial and final concentration, and pH were measured through titration, and a Digital pHmeter, respectively. Temperature analyses were measured through a thermocouple. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS The presence of violet light did not affect the amount of HP within the pulp chamber, or the CC (p > 0.05). Greater penetration of HP was observed within the pulp chamber, as well as CC when using 35% HP (p < 0.05). The final concentration of both gels was lower than the initial concentration, regardless of the use of violet light (p < 0.05). The initial and final pH levels remained neutral and stable (p > 0.05). The pulp temperature increased when the gels were used in conjunction with violet light (p < 0.05). CONCLUSIONS Using violet light in conjunction with 6% or 35% HP does not alter the physical properties of the bleaching agents, the penetration of HP or enhance color change. However, an increase in temperature was observed when violet light was applied associated with bleaching gels. CLINICAL RELEVANCE While the simultaneous use of violet light with hydrogen peroxide 6% or 35% does not alter the material's properties, it also does not bring benefits in reducing hydrogen peroxide penetration and improving color change. Furthermore, the use of violet light increases pulp temperature.
Collapse
Affiliation(s)
| | - Michael Willian Favoreto
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
| | | | - Taynara de Souza Carneiro
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
- Area of Stomatology, IDIBO Research Group, Health Sciences Faculty, Rey Juan Carlos University, Madrid, Spain
| | - Emanuel Adriano Hul
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
| | | | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil.
| | - Carlos Francci
- Department of Dental Materials, University of Sao Paulo, Sao Paulo, Brazil
| |
Collapse
|
5
|
Aidos M, Marto CM, Amaro I, Cernera M, Francisco I, Vale F, Marques-Ferreira M, Oliveiros B, Spagnuolo G, Carrilho E, Coelho A, Baptista Paula A. Comparison of in-office and at-home bleaching techniques: An umbrella review of efficacy and post-operative sensitivity. Heliyon 2024; 10:e25833. [PMID: 38371984 PMCID: PMC10873745 DOI: 10.1016/j.heliyon.2024.e25833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 01/29/2024] [Accepted: 02/02/2024] [Indexed: 02/20/2024] Open
Abstract
Objectives The objective of this umbrella review is to evaluate the efficacy and adverse effects of different teeth whitening techniques in-office (IO) and at-home (AH), regarding chromatic changes and teeth sensitivity. Materials and methods The search was carried out from several databases. The included studies were all systematic reviews with or without meta-analysis of RCT or quasi-RCT. The participants were patients that underwent external dental bleaching in permanent vital teeth. The interventions were in-office (IO) bleaching techniques and at-home (AT) bleaching techniques with different bleaching agents and concentrations. Results The search resulted in a total of 257 articles, and 28 SR were included in the qualitative analysis and nine in the quantitative analysis. There is no difference between in-office and at-home techniques in terms of color change (p = 0.95) and post-treatment sensitivity (p = 0.85). There is similarity risk and intensity of teeth sensitivity between AH and IO bleaching. IO bleaching with light-activated systems with low concentrations of bleaching agent showed similar results to IO bleaching techniques with high concentrated bleaching gels. With the application of the criteria of the AMSTAR 2 tool, the reviews were considered critically low to high. Conclusions There are no significant differences in terms of color change between the different bleaching techniques compared. Teeth sensitivity is always present regardless of the technique used. The use of light activation systems did not increase the intensity and risk of post-operative sensitivity.
Collapse
Affiliation(s)
- Maria Aidos
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
| | - Carlos Miguel Marto
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Institute of Experimental Pathology, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| | - Inês Amaro
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| | - Mariangela Cernera
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples, “Federico II”, 80131, Naples, Italy
| | - Inês Francisco
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Univ Coimbra, Institute of Orthodontics, Faculty of Medicine, Coimbra, Portugal
| | - Francisco Vale
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Univ Coimbra, Institute of Orthodontics, Faculty of Medicine, Coimbra, Portugal
| | - Manuel Marques-Ferreira
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Univ Coimbra, Institute of Endodontics, Faculty of Medicine, Coimbra, Portugal
| | - Bárbara Oliveiros
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Univ Coimbra, Laboratory of Biostatistics and Medical Informatics (LBIM), Faculty of Medicine, Coimbra, Portugal
| | - Gianrico Spagnuolo
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples, “Federico II”, 80131, Naples, Italy
| | - Eunice Carrilho
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| | - Ana Coelho
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| | - Anabela Baptista Paula
- Univ Coimbra, Institute of Integrated Clinical Practice, Faculty of Medicine, Coimbra, Portugal
- Univ Coimbra, Laboratory for Evidence-Based Sciences and Precision Dentistry, Coimbra, Portugal
- Univ Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra, Portugal
- Univ Coimbra, Center for Innovative Biomedicine and Biotechnology (CIBB), Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
| |
Collapse
|
6
|
Nagarkar S, Loguercio AD, Perdigão J. Evidence-based fact checking for selective procedures in restorative dentistry. Clin Oral Investig 2023; 27:475-488. [PMID: 36607490 DOI: 10.1007/s00784-022-04832-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 12/18/2022] [Indexed: 01/07/2023]
Abstract
OBJECTIVES Similar to other dental specialties, there are many clinical procedures in restorative dentistry that may or may not be supported by good evidence. Thus, the effectiveness of these procedures is uncertain. The aim of this paper is to reduce this knowledge gap by critically inspecting selective procedures in restorative dentistry and exploring if these well-established or widely advocated treatment modalities are necessary for improving treatment outcomes based on the best available evidence. MATERIALS AND METHODS A MEDLINE search was conducted to identify research on selective procedures while focusing on clinical trials and systematic reviews. Due to their practical relevance in the decision-making process, cost-effectiveness analyses were also included. RESULTS Mixed results were identified regarding the included interventions. Some procedures had adequate evidence supporting them while others were mostly based on beliefs. CONCLUSIONS A critical review of the available literature indicates that some common restorative procedures lack adequate support from high-quality research evidence. CLINICAL RELEVANCE This paper attempts to highlight the need to critically examine the scientific validity of traditional knowledge and techniques through the context of current research evidence. This will not only help generate consensus between educators, clinicians, and researchers regarding restorative procedures but will also lead to improved patient care and outcomes.
Collapse
Affiliation(s)
- Sanket Nagarkar
- Park Dental Group, Minneapolis, MN, USA.,Department of Restorative Sciences, University of Minnesota, Minneapolis, MN, USA
| | - Alessandro D Loguercio
- School of Dentistry, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | - Jorge Perdigão
- Division of Operative Dentistry, Department of Restorative Sciences, University of Minnesota, 515 SE Delaware St, 8-450 Moos Tower, Minneapolis, MN, 55455, USA.
| |
Collapse
|
7
|
Antunes EVG, Basting RT, do Amaral FLB, França FMG, Turssi CP, Kantovitz KR, Bronze-Uhle ES, Filho PNL, Basting RT. Titanium dioxide nanotubes in a hydrogen peroxide-based bleaching agent: physicochemical properties and effectiveness of dental bleaching under the influence of a poliwave led light activation. Clin Oral Investig 2022; 27:1745-1755. [PMID: 36441269 DOI: 10.1007/s00784-022-04802-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 11/22/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The effects of different concentrations of titanium dioxide (TiO2) into 40% hydrogen peroxide (HP) were evaluated as regards the effectiveness of dental color change either associated with activation by polywave LED light or not. MATERIALS AND METHODS TiO2 (0, 1, 5, or 10%) was incorporated into HP to be applied during in-office bleaching (3 sessions/40 min each). Polywave LED light (Valo Corded/Ultradent) was applied or not in activation cycles of 15 s (total time of 2 min). The color of 80 third molars separated into groups according to TiO2 concentration and light activation (n = 10) was evaluated at baseline and at time intervals after the 1st, 2nd, and 3rd bleaching sessions. RESULTS WID value was significantly higher when using HP with 5% TiO2 in the 2nd session than the values in the other groups (p < 0.05). After the 2nd and 3rd sessions, the ΔEab value was significantly higher when activated with light (p < 0.05) for all agents containing TiO2 or not. Zeta potential and pH of the agents were not modified by incorporating TiO2 at the different concentrations. CONCLUSIONS The 5% TiO2 in the bleaching agent could enhance tooth bleaching, even without light application. Association with polywave LED light potentiated the color change, irrespective of the presence of TiO2 in the bleaching gel. CLINICAL SIGNIFICANCE HP with 5% TiO2 could lead to a greater tooth bleaching response in the 2nd clinical session, as well as the polywave light can enhance color change.
Collapse
Affiliation(s)
| | - Rosanna Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, São Paulo, CEP: 13045-755, Brazil
| | | | | | - Cecilia Pedroso Turssi
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, São Paulo, CEP: 13045-755, Brazil
| | - Kamila Rosamilia Kantovitz
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, São Paulo, CEP: 13045-755, Brazil
| | - Erika Soares Bronze-Uhle
- School of Sciences, São Paulo State University (UNESP), Av. Eng. Luís Edmundo Carrijo Coube, 2085, Nucleo Res. Pres. Geisel, Bauru, São Paulo, CEP: 17033-360, Brazil
| | - Paulo Noronha Lisboa Filho
- School of Sciences, São Paulo State University (UNESP), Av. Eng. Luís Edmundo Carrijo Coube, 2085, Nucleo Res. Pres. Geisel, Bauru, São Paulo, CEP: 17033-360, Brazil
| | - Roberta Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, São Paulo, CEP: 13045-755, Brazil.
| |
Collapse
|
8
|
Tekce AU, Yazici AR. Clinical comparison of diode laser- and LED-activated tooth bleaching: 9-month follow-up. Lasers Med Sci 2022; 37:3237-3247. [PMID: 35829976 DOI: 10.1007/s10103-022-03612-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 07/07/2022] [Indexed: 11/29/2022]
Abstract
This study aims to evaluate the effect of diode laser- or LED-activated tooth bleaching on color change, tooth sensitivity(TS), temperature variation, and gingival irritation (GI) for 9 months. Thirty-five subjects having anterior teeth with a color of A2 or darker were enrolled in the study. In a split-mouth design, one side of each arch was activated by a diode laser (Epic X, Biolase), and the other side was activated by an LED (Radii Plus, SDI) in conjunction with a bleaching agent (35%, Whiteness HP). The color change was evaluated by subjective (VitaClassic/Vita3D Master Bleachguide) and objective (spectrophotometer, Vita Easyshade) methods for up to 9 months. TS and GI were assessed by visual analogue scale (VAS) and gingival index, respectively, at the same recall periods. During the bleaching, the temperature variation was also recorded using a thermocouple. Statistical analyses were performed (p < 0.05). In the color evaluation, no statistically significant difference was found between diode laser and LED (p > 0.05), except for the 6-month spectrophotometric assessment (ΔE00, ΔEab), where higher values were obtained with the laser (p < 0.05). The temperature difference and maximum temperature with diode were found to be significantly higher than LED (p < 0.05). Higher values were obtained with LED when the mean temperatures were compared (p < 0.05). There was no difference between the two activation methods in terms of TS and GI at any of the recalls (p > 0.05). The bleaching activated either with diode laser or LED performed similar clinical performance in terms of effective color change, tooth sensitivity, and gingival irritation with minimum temperature variations.
Collapse
Affiliation(s)
- Aybuke Uslu Tekce
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Sıhhıye, 06100, Ankara, Turkey.
| | - A Ruya Yazici
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Sıhhıye, 06100, Ankara, Turkey.,Research and Application Center for Laser Applications in Dentistry, Hacettepe University, Ankara, Turkey
| |
Collapse
|