1
|
Generalova AN, Vikhrov AA, Prostyakova AI, Apresyan SV, Stepanov AG, Myasoedov MS, Oleinikov VA. Polymers in 3D printing of external maxillofacial prostheses and in their retention systems. Int J Pharm 2024; 657:124181. [PMID: 38697583 DOI: 10.1016/j.ijpharm.2024.124181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 04/12/2024] [Accepted: 04/28/2024] [Indexed: 05/05/2024]
Abstract
Maxillofacial defects, arising from trauma, oncological disease or congenital abnormalities, detrimentally affect daily life. Prosthetic repair offers the aesthetic and functional reconstruction with the help of materials mimicking natural tissues. 3D polymer printing enables the design of patient-specific prostheses with high structural complexity, as well as rapid and low-cost fabrication on-demand. However, 3D printing for prosthetics is still in the early stage of development and faces various challenges for widespread use. This is because the most suitable polymers for maxillofacial restoration are soft materials that do not have the required printability, mechanical strength of the printed parts, as well as functionality. This review focuses on the challenges and opportunities of 3D printing techniques for production of polymer maxillofacial prostheses using computer-aided design and modeling software. Review discusses the widely used polymers, as well as their blends and composites, which meet the most important assessment criteria, such as the physicochemical, biological, aesthetic properties and processability in 3D printing. In addition, strategies for improving the polymer properties, such as their printability, mechanical strength, and their ability to print multimaterial and architectural structures are highlighted. The current state of the prosthetic retention system is presented with a focus on actively used polymer adhesives and the recently implemented prosthesis-supporting osseointegrated implants, with an emphasis on their creation from 3D-printed polymers. The successful prosthetics is discussed in terms of the specificity of polymer materials at the restoration site. The approaches and technological prospects are also explored through the examples of the nasal, auricle and ocular prostheses, ranging from prototypes to end-use products.
Collapse
Affiliation(s)
- Alla N Generalova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia; Federal Scientific Research Center "Crystallography and Photonics" of the Russian Academy of Sciences, 119333 Moscow, Russia.
| | - Alexander A Vikhrov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Anna I Prostyakova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Samvel V Apresyan
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Alexander G Stepanov
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Maxim S Myasoedov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Vladimir A Oleinikov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| |
Collapse
|
2
|
Çakın H, Yildirim Y, Ozsoy U. Demonstration of Cosmetic Improvement After Cranioplasty Using a Personalized 3D-Printed Mold for Creating Polymethylmethacrylate Implants With a Simplified Process. World Neurosurg 2024; 182:100-104. [PMID: 37995992 DOI: 10.1016/j.wneu.2023.11.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 11/16/2023] [Indexed: 11/25/2023]
Abstract
BACKGROUND Although personalized polymethylmethacrylate (PMMA) implant production molds for cranioplasty are costly and time-consuming, they allow for better-quality implants. The researchers quantitatively tested the contribution of simplified, low-cost techniques to cosmetic improvement. METHODS PMMA prosthesis was placed in a 25-year-old male patient due to osteolysis in the bone flap removed after decompression surgery. A single-sided mold was three-dimensional (3D) printed before the surgery, and the prosthesis was produced during the surgery. In addition, the change in cranial asymmetry was evaluated using a 3D surface scanner after surgery. RESULTS The mold took half an hour to design and 5 hours to print. The mold cost about 2 dollars. The root means square (RMS) value measured to determine cranial asymmetry decreased from 5.4 mm to 2.8 mm postoperatively. The patient stated that he was pretty satisfied with the cosmetic result. CONCLUSIONS Simple design techniques developed can offer low-cost, fast-design alternative solutions with satisfactory cosmetic results for low-income countries and patients.
Collapse
Affiliation(s)
- Hakan Çakın
- Department of Brain and Neurological Surgery, Akdeniz University, Faculty of Medicine, Antalya, Turkey
| | - Yilmaz Yildirim
- Department of Anatomy, Akdeniz University, Faculty of Medicine, Antalya, Turkey
| | - Umut Ozsoy
- Department of Anatomy, Akdeniz University, Faculty of Medicine, Antalya, Turkey.
| |
Collapse
|
3
|
Ji T, Yao P, Zeng Y, Qian Z, Wang K, Gao L. Subgaleal Effusion and Brain Midline Shift After Cranioplasty: A Retrospective Study Between Polyetheretherketone Cranioplasty and Titanium Cranioplasty After Decompressive Craniectomy. Front Surg 2022; 9:923987. [PMID: 35937601 PMCID: PMC9351718 DOI: 10.3389/fsurg.2022.923987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 06/10/2022] [Indexed: 11/21/2022] Open
Abstract
Cranioplasty with polyetheretherketone (PEEK) has recently shown better cerebral protection performance, improved brain function, and aesthetic contour compared with titanium mesh. However, whether patients undergoing PEEK cranioplasty tend to develop subgaleal effusions remains elusive. This retrospective study included patients who underwent cranioplasty with PEEK implants or titanium mesh after decompressive craniectomy between July 2017 and July 2020. Patient information, including general information, location, size of the defect, subgaleal depth, and brain midline shift was collected and statistically analyzed. There were 130 cases of cranioplasty, including 35 with PEEK implants and 95 with a titanium mesh. Patients who underwent cranioplasty with a PEEK implant had a higher subgaleal effusion rate than those who underwent cranioplasty with titanium mesh (85.71% vs. 53.68%, P < 0.001), while a midline shift >5 mm was more frequently observed in the PEEK group than in the titanium group (20% vs. 6.3%, P = 0.021). The PEEK material was the only factor associated with subgaleal effusion after cranioplasty (OR 5.589, P = 0.002). Logistic regression analysis further showed that age was a protective factor against midline shift in the PEEK cranioplasty group (OR 0.837, P = 0.029). Patients who underwent cranioplasty with PEEK implants were more likely to develop severe subgaleal effusion and significant brain midline shifts than those with titanium mesh implants.
Collapse
Affiliation(s)
- Tao Ji
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Peiwen Yao
- School of Clinical Medicine, Nanjing Medical University, Nanjing, China
| | - Yu Zeng
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Zhouqi Qian
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
| | - Ke Wang
- Department of Neurosurgery, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China
- Correspondence: Liang Gao Ke Wang
| | - Liang Gao
- School of Clinical Medicine, Nanjing Medical University, Nanjing, China
- Correspondence: Liang Gao Ke Wang
| |
Collapse
|
4
|
Ashraf M, Choudhary N, Kamboh UA, Raza MA, Sultan KA, Ghulam N, Hussain SS, Ashraf N. Early experience with patient-specific low-cost 3D-printed polymethylmethacrylate cranioplasty implants in a lower-middle-income-country: Technical note and economic analysis. Surg Neurol Int 2022; 13:270. [PMID: 35855120 PMCID: PMC9282781 DOI: 10.25259/sni_250_2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 06/08/2022] [Indexed: 11/06/2022] Open
Abstract
Background: Polymethyl methacrylate (PMMA) cranioplasty, while widely prevalent, has limitations associated with freehand manual intraoperative molding. PMMA has been superseded by titanium or Polyetheretherketone implants, prefabricated commercially from preoperative CT scans, and boasting superior clinical and cosmetic outcomes. However, such services are extremely inaccessible and unaffordable in the lower-middle-income country (LMIC) settings. The study aims to describe, in detail, the process of making ultra-low-cost patient-specific PMMA cranioplasty implants with minimum resources using open-access software. We report the first such service from the public health-care system within Pakistan, a LMIC. Methods: Using open-source software, preoperative CT heads were used to prefabricate three-dimensional implants. Both implant and cranial defects were printed using polylactic acid (PLA) to assess the implant’s size and fit preoperatively. From the PLA implant, we fashioned a silicon mold that shapes the PMMA implant. Ten patients who underwent cranioplasty using our technique for various cranial defects with at least a 12-month follow-up were retrospectively reviewed. Clinical, cosmetic, and radiological outcomes were objectively assessed. Results: Etiology of injury was trauma (8), malignant MCA infarct (1), and arteriovenous fistula (1). We produced seven frontotemporal-parietal implants, one bifrontal, one frontal, and one frontoparietal. At 1 year, eight patients reported their cosmetic appearance comparable to before the defect. Radiological outcome was classified as “excellent” for eight patients. No postoperative complications were encountered, nor did any implant have to be removed. One patient’s implant involving the orbital ridge had an unsatisfactory cosmetic outcome and required revision surgery. The average cost per implant to the National Health Service was US$40. Conclusion: Prefabricated patient-specific PMMA cranioplasty implants are cost-effective. A single surgeon can fashion them in a limited resource setting and provide personalized medicine with excellent clinical/cosmetic-radiological results. Our method produces patient-specific cranioplasty implants in an otherwise unaffordable LMIC setting.
Collapse
Affiliation(s)
- Mohammad Ashraf
- Wolfson School of Medicine, University of Glasgow, Scotland, United Kingdom,
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Nabeel Choudhary
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Usman Ahmad Kamboh
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Muhammad Asif Raza
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Kashif Ali Sultan
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Naseeruddin Ghulam
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Syed Shahzad Hussain
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| | - Naveed Ashraf
- Department of Neurosurgery, Allama Iqbal Medical College, Jinnah Hospital Lahore, Lahore, Pakistan
| |
Collapse
|
5
|
Steiert C, Behringer SP, Kraus LM, Bissolo M, Demerath T, Beck J, Grauvogel J, Reinacher PC. Augmented reality-assisted craniofacial reconstruction in skull base lesions - an innovative technique for single-step resection and cranioplasty in neurosurgery. Neurosurg Rev 2022; 45:2745-2755. [PMID: 35441994 PMCID: PMC9349131 DOI: 10.1007/s10143-022-01784-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 03/19/2022] [Accepted: 03/30/2022] [Indexed: 10/31/2022]
Abstract
Defects of the cranial vault often require cosmetic reconstruction with patient-specific implants, particularly in cases of craniofacial involvement. However, fabrication takes time and is expensive; therefore, efforts must be made to develop more rapidly available and more cost-effective alternatives. The current study investigated the feasibility of an augmented reality (AR)-assisted single-step procedure for repairing bony defects involving the facial skeleton and the skull base. In an experimental setting, nine neurosurgeons fabricated AR-assisted and conventionally shaped ("freehand") implants from polymethylmethacrylate (PMMA) on a skull model with a craniofacial bony defect. Deviations of the surface profile in comparison with the original model were quantified by means of volumetry, and the cosmetic results were evaluated using a multicomponent scoring system, each by two blinded neurosurgeons. Handling the AR equipment proved to be quite comfortable. The median volume deviating from the surface profile of the original model was low in the AR-assisted implants (6.40 cm3) and significantly reduced in comparison with the conventionally shaped implants (13.48 cm3). The cosmetic appearance of the AR-assisted implants was rated as very good (median 25.00 out of 30 points) and significantly improved in comparison with the conventionally shaped implants (median 14.75 out of 30 points). Our experiments showed outstanding results regarding the possibilities of AR-assisted procedures for single-step reconstruction of craniofacial defects. Although patient-specific implants still represent the gold standard in esthetic aspects, AR-assisted procedures hold high potential for an immediately and widely available, cost-effective alternative providing excellent cosmetic outcomes.
Collapse
Affiliation(s)
- Christine Steiert
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Simon Phillipp Behringer
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Luisa Mona Kraus
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Marco Bissolo
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Theo Demerath
- Department of Neuroradiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Juergen Beck
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Juergen Grauvogel
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Peter Christoph Reinacher
- Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Fraunhofer Institute for Laser Technology, Aachen, Germany
| |
Collapse
|
6
|
Msallem B, Maintz M, Halbeisen FS, Meyer S, Sigron GR, Sharma N, Cao S, Thieringer FM. Biomechanical Evaluation of Patient-Specific Polymethylmethacrylate Cranial Implants for Virtual Surgical Planning: An In-Vitro Study. MATERIALS 2022; 15:ma15051970. [PMID: 35269201 PMCID: PMC8911603 DOI: 10.3390/ma15051970] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 02/19/2022] [Accepted: 03/01/2022] [Indexed: 02/06/2023]
Abstract
Cranioplasty with freehand-molded polymethylmethacrylate implants is based on decades of experience and is still frequently used in clinical practice. However, data confirming the fracture toughness and standard biomechanical tests are rare. This study aimed to determine the amount of force that could be applied to virtually planned, template-molded, patient-specific implants (n = 10) with an implant thickness of 3 mm, used in the treatment of a temporoparietal skull defect (91.87 cm2), until the implant cracks and finally breaks. Furthermore, the influence of the weight and porosity of the implant on its force resistance was investigated. The primary outcome showed that a high force was required to break the implant (mean and standard deviation 1484.6 ± 167.7 N), and this was very strongly correlated with implant weight (Pearson’s correlation coefficient 0.97; p < 0.001). Secondary outcomes were force application at the implant’s first, second, and third crack. Only a moderate correlation could be found between fracture force and the volume of porosities (Pearson’s correlation coefficient 0.59; p = 0.073). The present study demonstrates that an implant thickness of 3 mm for a temporoparietal skull defect can withstand sufficient force to protect the brain. Greater implant weight and, thus, higher material content increases thickness, resulting in more resistance. Porosities that occur during the described workflow do not seem to reduce resistance. Therefore, precise knowledge of the fracture force of polymethylmethacrylate cranial implants provides insight into brain injury prevention and serves as a reference for the virtual design process.
Collapse
Affiliation(s)
- Bilal Msallem
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland; (B.M.); (N.S.); (S.C.); (F.M.T.)
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
| | - Michaela Maintz
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
| | - Florian S. Halbeisen
- Basel Institute for Clinical Epidemiology and Biostatistics, Department of Clinical Research, University Hospital Basel, University of Basel, CH-4031 Basel, Switzerland;
| | - Simon Meyer
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland; (B.M.); (N.S.); (S.C.); (F.M.T.)
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
- Correspondence:
| | - Guido R. Sigron
- Clinic of Oral and Cranio-Maxillofacial Surgery, Cantonal Hospital Aarau, CH-5001 Aarau, Switzerland;
| | - Neha Sharma
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland; (B.M.); (N.S.); (S.C.); (F.M.T.)
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
| | - Shuaishuai Cao
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland; (B.M.); (N.S.); (S.C.); (F.M.T.)
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
| | - Florian M. Thieringer
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland; (B.M.); (N.S.); (S.C.); (F.M.T.)
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland;
| |
Collapse
|
7
|
Pöppe JP, Spendel M, Schwartz C, Winkler PA, Wittig J. The "springform" technique in cranioplasty: custom made 3D-printed templates for intraoperative modelling of polymethylmethacrylate cranial implants. Acta Neurochir (Wien) 2022; 164:679-688. [PMID: 34873659 PMCID: PMC8913485 DOI: 10.1007/s00701-021-05077-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 11/23/2021] [Indexed: 12/19/2022]
Abstract
Background Manual moulding of cranioplasty implants after craniectomy is feasible, but does not always yield satisfying cosmetic results. In contrast, 3D printing can provide precise templates for intraoperative moulding of polymethylmethacrylate (PMMA) implants in cranioplasty. Here, we present a novel and easily implementable 3D printing workflow to produce patient-specific, sterilisable templates for PMMA implant moulding in cranioplastic neurosurgery. Methods 3D printable templates of patients with large skull defects before and after craniectomy were designed virtually from cranial CT scans. Both templates — a mould to reconstruct the outer skull shape and a ring representing the craniectomy defect margins — were printed on a desktop 3D printer with biocompatible photopolymer resins and sterilised after curing. Implant moulding and implantation were then performed intraoperatively using the templates. Clinical and radiological data were retrospectively analysed. Results Sixteen PMMA implants were performed on 14 consecutive patients within a time span of 10 months. The median defect size was 83.4 cm2 (range 57.8–120.1 cm2). Median age was 51 (range 21–80) years, and median operating time was 82.5 (range 52–152) min. No intraoperative complications occurred; PMMA moulding was uneventful and all implants fitted well into craniectomy defects. Excellent skull reconstruction could be confirmed in all postoperative computed tomography (CT) scans. In three (21.4%) patients with distinct risk factors for postoperative haematoma, revision surgery for epidural haematoma had to be performed. No surgery-related mortality or new and permanent neurologic deficits were recorded. Conclusion Our novel 3D printing-aided moulding workflow for elective cranioplasty with patient-specific PMMA implants proved to be an easily implementable alternative to solely manual implant moulding. The “springform” principle, focusing on reconstruction of the precraniectomy skull shape and perfect closure of the craniectomy defect, was feasible and showed excellent cosmetic results. The proposed method combines the precision and cosmetic advantages of computer-aided design (CAD) implants with the cost-effectiveness of manually moulded PMMA implants. Supplementary Information The online version contains supplementary material available at 10.1007/s00701-021-05077-7.
Collapse
Affiliation(s)
- Johannes P Pöppe
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria.
| | - Mathias Spendel
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Christoph Schwartz
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Peter A Winkler
- Department of Neurosurgery, University Hospital Salzburg, Paracelsus Medical University, Ignaz-Harrer-Str. 79, 5020, Salzburg, Austria
| | - Jörn Wittig
- Department of Oral and Maxillofacial Surgery, University Hospital Salzburg, Paracelsus Medical University, Müllner Hauptstraße 48, 5020, Salzburg, Austria
| |
Collapse
|
8
|
Reconstruction of Cranial Bone Defects Using Polyamide 12 Patient-Specific Implant: Long Term Follow Up. J Craniofac Surg 2022; 33:1825-1828. [PMID: 35119415 DOI: 10.1097/scs.0000000000008496] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Accepted: 01/12/2022] [Indexed: 11/26/2022] Open
Abstract
ABSTRACT The main objective of this study was to evaluate the use of patient-specific polyamide 12 implants in cranial bone defect reconstruction.Ten patients who underwent prior decompression craniectomy were selected for the current study. Skull scanning by computerized tomography was performed and used to make virtual planning of the implants to be transformed into physical implant using selective laser sintering. Cranioplasty was performed through coronal surgical approach where cranial implants were fixated using 2.0-mm mini-screws, and plates. Patients follow-up was from 12 to 36 months. Glasgow Outcome Score recorded 1 (good recovery) for all patients. Patient and surgeon satisfaction for the esthetic outcome were measured using visual analog scale as mean of 10 ± 0 and 9 ± 1, respectively. Cranial symmetry index was calculated as mean score of 98% ± 1%, indicating highly accurate symmetry, and preoperative virtual planning and postoperative outcome were compared for accuracy analysis with a mean difference of 0.3197 ± 0.1649, which indicates high accuracy.Polyamide12 cranial implants seem to offer a promising option to cranial bone reconstruction with patient-specific implants. This study ensures proper cosmetic and clinical outcome.
Collapse
|
9
|
Histological Processing of CAD/CAM Titanium Scaffold after Long-Term Failure in Cranioplasty. MATERIALS 2022; 15:ma15030982. [PMID: 35160928 PMCID: PMC8839919 DOI: 10.3390/ma15030982] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/17/2022] [Accepted: 01/25/2022] [Indexed: 02/01/2023]
Abstract
Cranioplasty is a frequently performed procedure after craniectomy and includes several techniques with different materials. Due to high overall complication rates, alloplastic implants are removed in many cases. Lack of implant material osseointegration is often assumed as a reason for failure, but no study has proven this in cranioplasty. This study histologically evaluates the osteointegration of a computer-aided design and computer-aided manufacturing (CAD/CAM) titanium scaffold with an open mesh structure used for cranioplasty. A CAD/CAM titanium scaffold was removed due to late soft tissue complications 7.6 years after cranioplasty. The histological analyses involved the preparation of non-decalcified slices from the scaffold’s inner and outer sides as well as a light-microscopic evaluation, including the quantification of the bone that had formed over the years. Within the scaffold pores, vital connective tissue with both blood vessels and nerves was found. Exclusive bone formation only occurred at the edges of the implant, covering 0.21% of the skin-facing outer surface area. The inner scaffold surface, facing towards the brain, did not show any mineralization at all. Although conventional alloplastic materials for cranioplasty reduce surgery time and provide good esthetic results while mechanically protecting the underlying structures, a lack of adequate stimuli could explain the limited bone formation found. CAD/CAM porous titanium scaffolds alone insufficiently osseointegrate in such large bone defects of the skull. Future research should investigate alternative routes that enable long-term osteointegration in order to reduce complication rates after cranioplasty. Opportunities could be found in mechano-biologically optimized scaffolds, material modifications, surface coatings, or other routes to sustain bone formation.
Collapse
|
10
|
A Narrative Review of Cell-Based Approaches for Cranial Bone Regeneration. Pharmaceutics 2022; 14:pharmaceutics14010132. [PMID: 35057028 PMCID: PMC8781797 DOI: 10.3390/pharmaceutics14010132] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 12/30/2021] [Accepted: 01/01/2022] [Indexed: 01/08/2023] Open
Abstract
Current cranial repair techniques combine the use of autologous bone grafts and biomaterials. In addition to their association with harvesting morbidity, autografts are often limited by insufficient quantity of bone stock. Biomaterials lead to better outcomes, but their effectiveness is often compromised by the unpredictable lack of integration and structural failure. Bone tissue engineering offers the promising alternative of generating constructs composed of instructive biomaterials including cells or cell-secreted products, which could enhance the outcome of reconstructive treatments. This review focuses on cell-based approaches with potential to regenerate calvarial bone defects, including human studies and preclinical research. Further, we discuss strategies to deliver extracellular matrix, conditioned media and extracellular vesicles derived from cell cultures. Recent advances in 3D printing and bioprinting techniques that appear to be promising for cranial reconstruction are also discussed. Finally, we review cell-based gene therapy approaches, covering both unregulated and regulated gene switches that can create spatiotemporal patterns of transgenic therapeutic molecules. In summary, this review provides an overview of the current developments in cell-based strategies with potential to enhance the surgical armamentarium for regenerating cranial vault defects.
Collapse
|
11
|
Atila D, Hasirci V, Tezcaner A. Coaxial electrospinning of composite mats comprised of core/shell poly(methyl methacrylate)/silk fibroin fibers for tissue engineering applications. J Mech Behav Biomed Mater 2022; 128:105105. [DOI: 10.1016/j.jmbbm.2022.105105] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/17/2022] [Accepted: 01/23/2022] [Indexed: 01/01/2023]
|
12
|
Feasibility of Customised Polymethyl Methacrylate Implants Fabricated Using 3D Printed Flexible Moulds for Correction of Facial Skeletal Deformities. J Craniofac Surg 2021; 32:1981-1985. [PMID: 33645954 DOI: 10.1097/scs.0000000000007383] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION Use of patient specific Polymethyl methacrylate (PMMA) implants for the reconstruction of cranial defects has become a standard practice with excellent long-term results. However, for the reconstruction of midface and mandibular osseous defects other alloplastic materials are preferred but their use is limited due to high cost. This is a report of our experience with the use of low-cost patient specific PMMA implants fabricated using 3D printed moulds in the reconstruction of osseous defects involving different areas of the facial skeleton not limited to cranium. METHODS The 25 consecutive patients with craniofacial osseous defects who underwent reconstruction using customized PMMA implants were analyzed. All PMMA implants were fabricated intraoperatively with the use of 3D printed flexible moulds or templates. RESULTS A total of 34 implants were used in 25 consecutive patients. Out of 34 implants 25 were used for midface and mandibular osseous defects. Most common etiology was post-traumatic deformity (n = 19) followed by tumor (n = 3), craniofacial anomalies (n = 2) and post-craniotomy (n = 1). One patient out of 25 (n = 1) had postoperative implant exposure. The follow-up was ranged from 3 to 19 months with an average of 12 months. The aesthetic outcome was found to be good to excellent with mean visual analogue score of 4.08. CONCLUSIONS Polymethyl methacrylate implants fabricated intraoperatively using 3D printed moulds provide accurate and precise reconstruction at an exceptionally low cost. PMMA has an excellent moulding property with low infection rates. As shown in our study its application may be easily extended to all areas of the craniofacial skeleton.
Collapse
|
13
|
Daoud GE, Pezzutti DL, Dolatowski CJ, Carrau RL, Pancake M, Herderick E, VanKoevering KK. Establishing a point-of-care additive manufacturing workflow for clinical use. JOURNAL OF MATERIALS RESEARCH 2021; 36:3761-3780. [PMID: 34248272 PMCID: PMC8259775 DOI: 10.1557/s43578-021-00270-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
Additive manufacturing, or 3-Dimensional (3-D) Printing, is built with technology that utilizes layering techniques to build 3-D structures. Today, its use in medicine includes tissue and organ engineering, creation of prosthetics, the manufacturing of anatomical models for preoperative planning, education with high-fidelity simulations, and the production of surgical guides. Traditionally, these 3-D prints have been manufactured by commercial vendors. However, there are various limitations in the adaptability of these vendors to program-specific needs. Therefore, the implementation of a point-of-care in-house 3-D modeling and printing workflow that allows for customization of 3-D model production is desired. In this manuscript, we detail the process of additive manufacturing within the scope of medicine, focusing on the individual components to create a centralized in-house point-of-care manufacturing workflow. Finally, we highlight a myriad of clinical examples to demonstrate the impact that additive manufacturing brings to the field of medicine.
Collapse
Affiliation(s)
| | | | | | - Ricardo L. Carrau
- The Ohio State University College of Medicine, Columbus, OH USA
- The Ohio State University James Comprehensive Cancer Center, Columbus, OH 43210 USA
- Department of Otolaryngology, The Ohio State University, Columbus, OH USA
| | - Mary Pancake
- Department of Engineering, The Ohio State University, Columbus, OH USA
| | - Edward Herderick
- Department of Engineering, The Ohio State University, Columbus, OH USA
| | - Kyle K. VanKoevering
- The Ohio State University College of Medicine, Columbus, OH USA
- The Ohio State University James Comprehensive Cancer Center, Columbus, OH 43210 USA
- Department of Otolaryngology, The Ohio State University, Columbus, OH USA
| |
Collapse
|
14
|
Barros da Silva E, da Silva Lobo C, Henrique de Aragão A, Martinelli de Oliveira R, de Paula Loureiro M, Ramina R. Using Cranial Sutures in a Single-Step Frame-Guided Resection and Reconstruction for Intraosseous Meningiomas: Technical Note. World Neurosurg 2021; 151:44-51. [PMID: 33895375 DOI: 10.1016/j.wneu.2021.04.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 04/11/2021] [Accepted: 04/12/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Single-stage surgical treatment of cranial intraosseous meningiomas includes complete tumor resection followed by aesthetic reconstruction. Tailored tumor resection with a computer-aided design/computer-aided manufacturing custom-made implant for the defect has been advocated in recent years to achieve a satisfactory cosmetic result with reduced operative time and fewer complications. However, several technical nuances related to the area of osseous removal may compromise cranioplasty. METHODS We present 2 cases of intraosseous meningiomas (sphenoid wing and retromastoid) to illustrate a step-by-step approach, from preoperative planning to single-step surgery. RESULTS For each case, a customized frame template delimiting bone removal was designed using cranial sutures as anatomical landmarks for precise placement of the cranioplasty template over the area of interest. CONCLUSIONS Custom templates based in cranial sutures may benefit single-step frame-guided resection and reconstruction of intraosseous tumors with compelling results.
Collapse
Affiliation(s)
- Erasmo Barros da Silva
- Department of Neurosurgery, Instituto de Neurologia de Curitiba, Curitiba, Paraná, Brazil.
| | | | | | | | - Marcelo de Paula Loureiro
- Postgraduate Department of Industrial Biotechnology, Universidade Positivo, Curitiba, Paraná, Brazil
| | - Ricardo Ramina
- Department of Neurosurgery, Instituto de Neurologia de Curitiba, Curitiba, Paraná, Brazil
| |
Collapse
|
15
|
Yerragunta T, Kanala RR, Yerramneni VK, Kolpakawar S, Rangan V. Designer Cranioplasty at Budget Prices: A Novel Use of 3D Printing Technology. INDIAN JOURNAL OF NEUROSURGERY 2021. [DOI: 10.1055/s-0040-1716995] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
Abstract
Background Cranioplasty using synthetic materials for restoration of the exact shape of the skull has always remained a challenge until the development of 3D printing technology. However, the high-cost of available 3D printed implants limits their extensive use.
Objectives To study the effectiveness of a low-cost, 3D-printed template for molding the polymethyl methacrylate (PMMA) (bone cement) in order to achieve exact contours of the skull specific to each patient.
Materials and Methods 10 cranioplasties have been performed between July 2018 to December 2019 in a variety of craniotomy defects using bone cement flaps shaped using custom-made molds. The mold was 3D-printed and based on each patient’s CT images in digital imaging and communications in medicine (DICOM). Miniplates and screws were used to fix the flap. Postoperatively, clinical and radiological evaluation were done to assess patient satisfaction and accuracy of contour achieved.
Results Patient satisfaction as well as accuracy of contouring, as seen on postoperative CT scans, were excellent. There were no notable complications on follow-up.
Conclusion PMMA cranioplasty flap, contoured using a 3D-printed mold, is a very cost-effective alternative for restoration of skull contour for various craniotomy defects.Polymethyl methacrylate (PMMA) molded to form the exact shape of lost calvarium using 3D printed plastic templates is a smart and economical solution.
Collapse
Affiliation(s)
- Thirumal Yerragunta
- Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Panjagutta, Hyderabad, India
| | - Reddy Ramanadha Kanala
- Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Panjagutta, Hyderabad, India
| | | | - Swapnil Kolpakawar
- Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Panjagutta, Hyderabad, India
| | - Vasundhara Rangan
- Department of Neurosurgery, Nizam’s Institute of Medical Sciences, Panjagutta, Hyderabad, India
| |
Collapse
|
16
|
da Silva Júnior EB, de Aragão AH, de Paula Loureiro M, Lobo CS, Oliveti AF, de Oliveira RM, Ramina R. Cranioplasty with three-dimensional customised mould for polymethylmethacrylate implant: a series of 16 consecutive patients with cost-effectiveness consideration. 3D Print Med 2021; 7:4. [PMID: 33548008 PMCID: PMC7866687 DOI: 10.1186/s41205-021-00096-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 01/31/2021] [Indexed: 02/08/2023] Open
Abstract
Background Different methods of cranioplasty for the reconstruction of bony skull defects exist. In the absence of the autologous bone flap, a customised manufactured implant may be the optimal choice, but this implant has several limitations regarding its technical standardisation and better cost-effectiveness. Methods This study presents a series of 16 consecutive patients who had undergone cranioplasty with customised three-dimensional (3D) template moulds for polymethylmethacrylate (PMMA) implants manufactured after 3D modelling on a specific workstation. The virtual images were transformed into a two-piece physical model using a 3D printer for the biomaterials. PMMA implant was produced intraoperatively with the custom mould. Cosmetic results were analysed by comparing pre- and postoperative 3D computed tomography (CT) images and asking if the patient was satisfied with the result. Results The average total time for planning and production of customised mould was 10 days. The 16 patients were satisfied with the result, and CT images presented harmonious symmetry when comparing pre- and postoperative scans. Cases of postoperative infection, bleeding, or reoperation in this series were not observed. Conclusion Cranioplasty with high-technology customised 3D moulds for PMMA implants can allow for an aesthetic reconstruction with a fast and cost-effective manufacturing process and possibly with low complication rates.
Collapse
Affiliation(s)
- Erasmo Barros da Silva Júnior
- Department of Neurosurgery, Instituto de Neurologia de Curitiba, Jeremias Maciel Perretto, 300 - Campo Comprido, Curitiba, Paraná, 81210-310, Brazil.
| | - Afonso Henrique de Aragão
- Department of Neurosurgery, Instituto de Neurologia de Curitiba, Jeremias Maciel Perretto, 300 - Campo Comprido, Curitiba, Paraná, 81210-310, Brazil
| | | | | | | | | | - Ricardo Ramina
- Department of Neurosurgery, Instituto de Neurologia de Curitiba, Jeremias Maciel Perretto, 300 - Campo Comprido, Curitiba, Paraná, 81210-310, Brazil
| |
Collapse
|
17
|
Francoisse CA, Sescleifer AM, King WT, Lin AY. Three-dimensional printing in medicine: a systematic review of pediatric applications. Pediatr Res 2021; 89:415-425. [PMID: 32503028 DOI: 10.1038/s41390-020-0991-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 05/01/2020] [Accepted: 05/04/2020] [Indexed: 01/17/2023]
Abstract
BACKGROUND Three-dimensional printing (3DP) addresses distinct clinical challenges in pediatric care including: congenital variants, compact anatomy, high procedural risk, and growth over time. We hypothesized that patient-specific applications of 3DP in pediatrics could be categorized into concise, discrete categories of use. METHODS Terms related to "three-dimensional printing" and "pediatrics" were searched on PubMed, Scopus, Ovid MEDLINE, Cochrane CENTRAL, and Web of Science. Initial search yielded 2122 unique articles; 139 articles characterizing 508 patients met full inclusion criteria. RESULTS Four categories of patient-specific 3DP applications were identified: Teaching of families and medical staff (9.3%); Developing intervention strategies (33.9%); Procedural applications, including subtypes: contour models, guides, splints, and implants (43.0%); and Material manufacturing of shaping devices or prosthetics (14.0%). Procedural comparative studies found 3DP devices to be equivalent or better than conventional methods, with less operating time and fewer complications. CONCLUSION Patient-specific applications of Three-Dimensional Printing in Medicine can be elegantly classified into four major categories: Teaching, Developing, Procedures, and Materials, sharing the same TDPM acronym. Understanding this schema is important because it promotes further innovation and increased implementation of these devices to improve pediatric care. IMPACT This article classifies the pediatric applications of patient-specific three-dimensional printing. This is a first comprehensive review of patient-specific three-dimensional printing in both pediatric medical and surgical disciplines, incorporating previously described classification schema to create one unifying paradigm. Understanding these applications is important since three-dimensional printing addresses challenges that are uniquely pediatric including compact anatomy, unique congenital variants, greater procedural risk, and growth over time. We identified four classifications of patient-specific use: teaching, developing, procedural, and material uses. By classifying these applications, this review promotes understanding and incorporation of this expanding technology to improve the pediatric care.
Collapse
Affiliation(s)
- Caitlin A Francoisse
- Division of Plastic Surgery, Saint Louis University School of Medicine, St. Louis, MO, USA
| | - Anne M Sescleifer
- Division of Plastic Surgery, Saint Louis University School of Medicine, St. Louis, MO, USA
| | - Wilson T King
- Division of Pediatric Cardiology, Saint Louis University School of Medicine, St. Louis, MO, USA.,SSM Health Cardinal Glennon Children's Hospital at SLU, St. Louis, MO, USA
| | - Alexander Y Lin
- Division of Plastic Surgery, Saint Louis University School of Medicine, St. Louis, MO, USA. .,SSM Health Cardinal Glennon Children's Hospital at SLU, St. Louis, MO, USA.
| |
Collapse
|
18
|
Basu B, Bhaskar N, Barui S, Sharma V, Das S, Govindarajan N, Hegde P, Perikal PJ, Antharasanahalli Shivakumar M, Khanapure K, Tekkatte Jagannatha A. Evaluation of implant properties, safety profile and clinical efficacy of patient-specific acrylic prosthesis in cranioplasty using 3D binderjet printed cranium model: A pilot study. J Clin Neurosci 2021; 85:132-142. [PMID: 33581784 DOI: 10.1016/j.jocn.2020.12.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 12/14/2020] [Indexed: 01/21/2023]
Abstract
There exists a significant demand to develop patient-specific prosthesis in reconstruction of cranial vaults after decompressive craniectomy. we report here, the outcomes of an unicentric pilot study on acrylic cranial prosthesis fabricated using a 3D printed cranium model with its clinically relevant mechanical properties. METHODS The semi-crystalline polymethyl methacrylate (PMMA) implants, shaped to the cranial defects of 3D printed cranium model, were implanted in 10 patients (mean age, 40.8 ± 14.8 years). A binderjet 3D printer was used to create patient-specific mould and PMMA was casted to fabricate prosthesis which was analyzed for microstructure and properties. Patients were followed up for allergy, infection and cosmesis for a period of 6 months. RESULTS As-cast PMMA flap exhibited hardness of 15.8 ± 0.24Hv, tensile strength of 30.7 ± 3.9 MPa and elastic modulus of 1.5 ± 0.1 GPa. 3D microstructure of the semi-crystalline acrylic implant revealed 2.5-15 µm spherical isolated pores. The mean area of the calvarial defect in craniectomy patients was 94.7 ± 17.4 cm2. We achieved a cranial index of symmetry (CIS -%) of 94.5 ± 3.9, while the average post-operative Glasgow outcome scale (GOS) score recorded was 4.2 ± 0.9. CONCLUSIONS 3D printing based patient-specific design and fabrication of acrylic cranioplasty implant is safe and achieves acceptable cosmetic and clinical outcomes in patients with decompressive craniectomy. Our study ensured clinically acceptable structural and mechanical properties of implanted PMMA, suggesting that a low cost 3D printer based PMMA flap is an affordable option for cranioplasty in resource constrained settings.
Collapse
Affiliation(s)
- Bikramjit Basu
- Materials Research Center, Indian Institute of Science, Bangalore 560012, India; Center for BioSystems Science and Engineering, Indian Institute of Science, Bangalore 560012, India
| | - Nitu Bhaskar
- Materials Research Center, Indian Institute of Science, Bangalore 560012, India
| | - Srimanta Barui
- Materials Research Center, Indian Institute of Science, Bangalore 560012, India
| | - Vidushi Sharma
- Materials Research Center, Indian Institute of Science, Bangalore 560012, India
| | - Soumitra Das
- Materials Research Center, Indian Institute of Science, Bangalore 560012, India
| | - Nikhil Govindarajan
- Department of Metallurgical and Materials Engineering, National Institute of Technology, Surathkal, Mangaluru 575025, Karnataka, India
| | - Pranoy Hegde
- Department of Neurosurgery, Ramaiah Medical College, Bengaluru, Karnataka 560054, India
| | - Parichay J Perikal
- Department of Neurosurgery, Ramaiah Medical College, Bengaluru, Karnataka 560054, India
| | | | - Kiran Khanapure
- Department of Neurosurgery, Ramaiah Medical College, Bengaluru, Karnataka 560054, India
| | | |
Collapse
|
19
|
Processing Conditions of a Medical Grade Poly(Methyl Methacrylate) with the Arburg Plastic Freeforming Additive Manufacturing Process. Polymers (Basel) 2020; 12:polym12112677. [PMID: 33198390 PMCID: PMC7696228 DOI: 10.3390/polym12112677] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 11/17/2022] Open
Abstract
The Arburg Plastic Freeforming process (APF) is a unique additive manufacturing material jetting method. In APF, a thermoplastic material is supplied as pellets, melted and selectively deposited as droplets, enabling the use of commercial materials in their original shape instead of filaments. The medical industry could significantly benefit from the use of additive manufacturing for the onsite fabrication of customized medical aids and therapeutic devices in a fast and economical way. In the medical field, the utilized materials need to be certified for such applications and cannot be altered in any way to make them printable, because modifications annul the certification. Therefore, it is necessary to modify the processing conditions rather than the materials for successful printing. In this research, a medical-grade poly(methyl methacrylate) was analyzed. The deposition parameters were kept constant, while the drop aspect ratio, discharge rate, melt temperatures, and build chamber temperature were varied to obtain specimens with different geometrical accuracy. Once satisfactory geometrical accuracy was obtained, tensile properties of specimens printed individually or in batches of five were tested in two different orientations. It was found that parts printed individually with an XY orientation showed the highest tensile properties; however, there is still room for improvement by optimizing the processing conditions to maximize the mechanical strength of printed specimens.
Collapse
|
20
|
Yang MX, Chen B, Zhang YP, Zhao ZH. Feasibility of customizing titanium implant with three-dimensional CT imaging of low dose in skull. Medicine (Baltimore) 2020; 99:e21009. [PMID: 32664105 PMCID: PMC7360305 DOI: 10.1097/md.0000000000021009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
OBJECT To explore the feasibility and practicability of making virtual three-dimensional model of skull defect and customizing titanium implant by skull three-dimensional CT examination of low dose. METHODS Sixty patients with skull defects who underwent skull three-dimensional CT before cranioplasty were randomly divided into 4 groups: group A (conventional dose 120 peak Kilovoltage (kVp), 150 tube current time product (mAs)), low dose group B (120 kVp, 50 mAs), low dose group C (100 kVp, 50 mAs), low dose group D (100 kVp, 30 mAs). After the scanning, we compared radiation doses and image quality among the groups. The CT data were sent to the reconstruction company to produce accurate titanium implants, and neurosurgeons performed cranioplasty. After the operation, patients immediately underwent head CT scans to confirm the accuracy of the implantation position, and a series of clinical functions were evaluated. RESULTS There were significant differences in dose length product (DLP) and effective dose (ED) among the 4 groups (P < .001). The volume CT dose index (CDTIvol), DLP, and ED in group D were, respectively, 87.1%, 86.9%, and 87.3% lower than those in group A (P < .001). All images quality were at or above the general level, and there was no statistical difference (P > .05). Titanium implants were successfully manufactured, every cranioplasty was carried out smoothly, and the clinical function of patients recovered well. CONCLUSION Customizing titanium implant with three-dimensional CT imaging of low dose in skull not only met the clinical requirements, but also significantly reduced the radiation dose and hazard.
Collapse
Affiliation(s)
- Min-Xia Yang
- Department of Radiology, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, Zhejiang Province, China
| | | | | | | |
Collapse
|
21
|
Policicchio D, Casu G, Dipellegrini G, Doda A, Muggianu G, Boccaletti R. Comparison of two different titanium cranioplasty methods: Custom-made titanium prostheses versus precurved titanium mesh. Surg Neurol Int 2020; 11:148. [PMID: 32637201 PMCID: PMC7332511 DOI: 10.25259/sni_35_2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 05/13/2020] [Indexed: 11/16/2022] Open
Abstract
Background: The aim of this study was to compare the results of two different titanium cranioplasties for reconstructing skull defects: standard precurved mesh versus custom-made prostheses. Methods: Retrospective analysis of 23 patients submitted to titanium cranioplasty between January 2014 and January 2019. Ten patients underwent delayed cranioplasty using custom-made prostheses; and 13 patients were treated using precurved titanium mesh (ten delayed cranioplasties, and three single-stage resection- reconstructions). Demographic, clinical, and radiological data were recorded. Results and complications of the two methods were compared, including duration of surgery, cosmetic results (visual analog scale for cosmesis [VASC]), and costs of the implants. Results: Complications: one epidural hematoma in the custom-made group, one delayed failure in precurved group due to wound dehiscence with mesh exposure. There were no infections in either group. All custom-made prostheses perfectly fitted on the defect; eight of 13 precurved mesh prostheses incompletely covered the defect. Custom-made cranioplasty obtained better cosmetic results (average VASC 94 vs. 68), shorter surgical time (141min vs. 186min), and -fewer screws was needed to fix the prostheses in place (6 vs. 15). However, satisfactory results were obtained using precurved mesh in cases of small defects and in single-stage reconstruction. Precurved mesh was found to be cheaper (€1,500 vs. €5,500). Conclusion: Custom-made cranioplasty obtained better results and we would suggest that this should be a first choice, particularly for young patients with a large cranial defect. Precurved mesh was cheaper and useful for single-stage resection-reconstruction. Depending on the individual conditions, both prostheses have their place in cranioplasty therapies.
Collapse
Affiliation(s)
- Domenico Policicchio
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| | - Gina Casu
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| | - Giosuè Dipellegrini
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| | - Artan Doda
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| | - Giampiero Muggianu
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| | - Riccardo Boccaletti
- Department of Neurosurgery, Azienda Ospedaliero Universitaria di Sassari, Via Enrico De Nicola, Sassari, Italy
| |
Collapse
|
22
|
A case of resorbable mesh cranioplasty in infant, technical considerations, outcome and literature review. INTERDISCIPLINARY NEUROSURGERY 2020. [DOI: 10.1016/j.inat.2019.100635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
23
|
Mechanical properties of polymeric implant materials produced by extrusion-based additive manufacturing. J Mech Behav Biomed Mater 2020; 104:103611. [DOI: 10.1016/j.jmbbm.2019.103611] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Revised: 12/13/2019] [Accepted: 12/30/2019] [Indexed: 01/08/2023]
|
24
|
Surgical preference regarding different materials for custom-made allograft cranioplasty in patients with calvarial defects: Results from an internal audit covering the last 20 years. J Clin Neurosci 2020; 74:98-103. [DOI: 10.1016/j.jocn.2020.01.087] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 01/27/2020] [Indexed: 11/19/2022]
|
25
|
Abstract
Custom made cranioplasty (CM CPL) represents the gold standard for cranial defect reconstruction, allowing an adequate protection of the brain with good cosmetic results. Nevertheless, it is an expensive procedure, requiring time for preparation of the prothesis. Aim of this study is to evaluate whether and in what cases handmade cranioplasty (HM CPL) still represents a valid alternative to CM CPL.Therefore, all consecutive cranioplasties in our center from 2013 to 2019 have been analyzed. Size and location of cranial defect have been considered, as the cause of decompression. Morbidity rate and final outcome have been evaluated. Series includes 143 patients (61% males, mean age: 60 years, SD:16). HM CPL was performed in 59 cases (41.2%) and CM in the remaining 84 (58.8%). HM CPL was preferred for smaller cranial defects (p: 0.22), inferior to 100 cm (p: 0.01) located in fronto-parietal-occipital area (p: 0.01). Furthermore, HM CPL results in the first choice after removal of infiltrative tumors (p: 0.02). Surgical complications consisted in 14 (9%) infections, 8 hematomas (5.6%), and one cranioplasty displacement (0.7%). At follow-up, in 85.3% of cases the CPL is still in place with satisfactory cosmetic and functional outcome (86.5% of HM CPL, 84.5% of CM CPL).HM CPL may still represent an effective and economic alternative procedure, when specific patient selection criteria are respected. This technique requires a long learning learning curve and demanding surgical maneuvers. Our handmade reconstruction technique with some hints to improve the esthetic result is presented.
Collapse
|
26
|
Martín-Noguerol T, Paulano-Godino F, Riascos RF, Calabia-Del-Campo J, Márquez-Rivas J, Luna A. Hybrid computed tomography and magnetic resonance imaging 3D printed models for neurosurgery planning. ANNALS OF TRANSLATIONAL MEDICINE 2019; 7:684. [PMID: 31930085 DOI: 10.21037/atm.2019.10.109] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
In the last decade, the clinical applications of three-dimensional (3D) printed models, in the neurosurgery field among others, have expanded widely based on several technical improvements in 3D printers, an increased variety of materials, but especially in postprocessing software. More commonly, physical models are obtained from a unique imaging technique with potential utilization in presurgical planning, generation/creation of patient-specific surgical material and personalized prosthesis or implants. Using specific software solutions, it is possible to obtain a more accurate segmentation of different anatomical and pathological structures and a more precise registration between different medical image sources allowing generating hybrid computed tomography (CT) and magnetic resonance imaging (MRI) 3D printed models. The need of neurosurgeons for a better understanding of the complex anatomy of central nervous system (CNS) and spine is pushing the use of these hybrid models, which are able to combine morphological information from CT and MRI, and also able to add physiological data from advanced MRI sequences, such as diffusion-weighted imaging (DWI), diffusion tensor imaging (DTI), perfusion weighted imaging (PWI) and functional MRI (fMRI). The inclusion of physiopathological data from advanced MRI sequences enables neurosurgeons to identify those areas with increased biological aggressiveness within a certain lesion prior to surgery or biopsy procedures. Preliminary data support the use of this more accurate presurgical perspective, to select the better surgical approach, reduce the global length of surgery and minimize the rate of intraoperative complications, morbidities or patient recovery times after surgery. The use of 3D printed models in neurosurgery has also demonstrated to be a valid tool for surgeons training and to improve communication between specialists and patients. Further studies are needed to test the feasibility of this novel approach in common clinical practice and determine the degree of improvement the neurosurgeons receive and the potential impact on patient outcome.
Collapse
Affiliation(s)
| | | | - Roy F Riascos
- Department of Neuroradiology, The University of Texas Health Science Center at Houston, McGovern Medical School, Texas, USA
| | | | | | - Antonio Luna
- MRI Unit, Radiology Department, HT Médica, Jaén, Spain
| |
Collapse
|
27
|
Cranioplasty after craniectomy in pediatric patients-a systematic review. Childs Nerv Syst 2019; 35:1481-1490. [PMID: 30610476 DOI: 10.1007/s00381-018-4025-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2018] [Accepted: 12/10/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Complications following cranioplasty with either autografts or cranial implants are commonly reported in pediatric patients. However, data regarding cranioplasty strategies, complications and long-term outcomes are not well described. This study systematically reviews the literature for an overview of current cranioplasty practice in children. METHODS A systematic review of articles published from inception to July 2018 was performed. Studies were included if they reported the specific use of cranioplasty materials following craniectomy in patients younger than 18 years of age, and had a minimum follow-up of at least 1 year. RESULTS Twenty-four manuscripts, describing a total of 864 cranioplasty procedures, met the inclusion criteria. The age of patients in this aggregate ranged from 1 month to 20 years and the weighted average was 8.0 years. The follow-up ranged from 0.4 months to 18 years and had a weighted average of 40.4 months. Autologous bone grafts were used in 484 cases (56.0%). Resorption, infection and/or hydrocephalus were the most frequently mentioned complications. In this aggregate group, 61 patients needed a revision cranioplasty. However, in 6/13 (46%) papers studying autologous cranioplasties, no data was provided on resorption, infection and revision cranioplasty rates. Cranial implants were used in 380 cases (44.0%), with custom-made porous hydroxyapatite being the most commonly used material (100/380, 26.3%). Infection and migration/fracturing/loosening were the most frequently documented complications. Eleven revision cranioplasties were reported. Again, no data was reported on infection and revision cranioplasty rates, in 7/16 (44%) and 9/16 (56%) of papers, respectively. CONCLUSION Our systematic review illuminates that whether autografts or cranial implants are used, postcranioplasty complications are quite common. Beyond this, the existing literature does not contain well documented and comparable outcome parameters, suggesting that prospective, long-term multicenter cohort studies are needed to be able to optimize cranioplasty strategies in children who will undergo cranioplasty following craniectomy.
Collapse
|
28
|
From decompressive craniectomy to cranioplasty and beyond-a pediatric neurosurgery perspective. Childs Nerv Syst 2019; 35:1517-1524. [PMID: 31327037 DOI: 10.1007/s00381-019-04303-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 07/08/2019] [Indexed: 01/05/2023]
Abstract
PURPOSE Decompressive craniectomy (DC) is an established neurosurgical emergency technique. Patient selection, optimal timing, and technical aspects related to DC and subsequent cranioplasty remain subjects of debate. For children, the overall degree of evidence is low, compared with randomized controlled trials (RCTs) in adults. METHODS Here, we present a detailed retrospective analysis of pediatric DC, covering the primary procedure and cranioplasty. Results are analyzed and discussed in the light of modern scientific evidence, and conclusions are drawn to stimulate future research. RESULTS The main indication for DC in children is traumatic brain injury (TBI). Primary and secondary DC is performed with similar frequency. Outcome appears to be better than that in adults, although long-term complications (especially bone flap resorption after autologous cranioplasty) are more common in children. Overt clinical signs of cerebral herniation prior to DC are predictors of poor outcome. CONCLUSIONS We conclude that DC is an important option in the armamentarium to treat life-threatening intracranial hypertension, but further research is warranted, preferentially in a multicenter prospective registry.
Collapse
|
29
|
Cranioplasties following craniectomies in children-a multicenter, retrospective cohort study. Childs Nerv Syst 2019; 35:1473-1480. [PMID: 30554262 DOI: 10.1007/s00381-018-4024-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 12/10/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE Complications following pediatric cranioplasty after craniectomy with either autologous bone flaps or cranial implants are reported to be common, particularly bone flap resorption. However, only sparse data are available regarding cranioplasty strategies, complications, and outcomes. This manuscript describes a Canadian-Dutch multicenter pediatric cohort study with autografts and cranial implant cranioplasties following craniectomies for a variety of indications. METHODS The study included all children (< 18 years) who underwent craniectomy and subsequent cranioplasty surgeries from 2008 to 2014 (with a minimum of 1-year follow-up) at four academic hospitals with a dedicated pediatric neurosurgical service. Data were collected regarding initial diagnosis, age, time interval between craniectomy and cranioplasty, bone flap storage method, type of cranioplasty for initial procedure (and redo if applicable), and the postoperative outcome including surgical site infection, wound breakdowns, bone flap resorption, and inadequate fit/disfigurement. RESULTS Sixty-four patients (46 males, average age 9.7 ± 5.5 years) were eligible for inclusion, with mean follow-up of 82.3 ± 31.2 months after craniectomy. Forty cranioplasties (62.5%) used autologous bone re-implant, 23 (57.5%) of which showed resorption. On average, resorption was documented at 434 days (range 62-2796 days) after reimplantation. In 20 cases, a revision cranioplasty was needed. In 24 of the post-craniectomy cases (37.5%), a cranial implant was used with one of ten different implant types. Implant loosening prompted a complete revision cranioplasty in 2 cases (8.3%). Cranial implants were associated with low morbidity and lower reoperation dates compared to the autologous cranioplasties. CONCLUSION The most prominent finding in this multicenter cohort study was that bone flap resorption in children remains a common and widespread problem following craniectomy. Cranioplasty strategies varied between centers and evolved over time within centers. Cranial implants were associated with low morbidity and low reoperation rates. Still, longer term and prospective multicenter cohort studies are needed to optimize cranioplasty strategies in children after craniectomies.
Collapse
|
30
|
|
31
|
Transcranioplasty Ultrasound Through a Sonolucent Cranial Implant Made of Polymethyl Methacrylate: Phantom Study Comparing Ultrasound, Computed Tomography, and Magnetic Resonance Imaging. J Craniofac Surg 2019; 30:e626-e629. [PMID: 31188246 DOI: 10.1097/scs.0000000000005651] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Current methods of transcranial diagnostic ultrasound imaging are limited by the skull's acoustic properties. Craniotomy, craniectomy, and cranioplasty procedures present opportunities to circumvent these limitations by substituting autologous bone with synthetic cranial implants composed of sonolucent biomaterials. OBJECTIVE This study examined the potential to image the brain using transcranioplasty ultrasound (TCU) through a sonolucent cranial implant. MATERIALS AND METHODS A validated adult brain phantom was imaged using computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound without an implant. Next, for experimental comparison, TCU was performed through a sonolucent implant composed of clear polymethyl methacrylate. RESULTS All imaging modalities successfully revealed elements of the brain phantom, including the bilateral ventricular system, the falx cerebri, and a deep hyperdense mass representing a brain tumor or hematoma. In addition, ultrasound images were captured which closely resembled axial images obtained with both CT and MRI. CONCLUSION The results obtained in this first-ever, preclinical, phantom study suggest TCU is now a viable immediate and long-term diagnostic imaging modality deserving of further clinical investigation.
Collapse
|
32
|
Talamonti G, Crisà F, Canzi G. Transplant of Adult Bone for Reconstruction of a Large Post-Traumatic Cranial Defect in a Very Young Baby. Pediatr Neurosurg 2019; 54:218-222. [PMID: 30879012 DOI: 10.1159/000496694] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Accepted: 01/04/2019] [Indexed: 11/19/2022]
Abstract
Large cranial defects in very young patients are challenging. The ideal material for cranioplasty in this age group has not yet been identified. Cryopreserved autologous bone presents very high rates of failures, acrylic resins pose a number of compatibility problems, bioceramics may be contraindicated, and autografts may be not adequate for repair of large defects. We present an 18-month-old baby with a large post-traumatic cranial defect which was repaired by assembling a new bone flap on a sterile stereolithographic 3-D model. This customized newly assembled flap consisted of a scaffold of autologous bone (from vault duplication) sustaining 2 large grafts of homologous cadaveric bone. It was adequately modeled and contoured on the 3-D model using metallic plates and screws. Immediately after implantation on the skull, the metallic devices were progressively replaced by reabsorbable material, thus maintaining the previously obtained flap profile. In this paper we detail this original technique which was developed to manage this specific patient.
Collapse
Affiliation(s)
| | - Francesco Crisà
- Department of Neurosurgery, Niguarda Ca'Granda Hospital, Milan, Italy
| | - Gabriele Canzi
- Maxillofacial Departmental Structure, ASST Niguarda, Milan, Italy
| |
Collapse
|
33
|
Chepelev L, Wake N, Ryan J, Althobaity W, Gupta A, Arribas E, Santiago L, Ballard DH, Wang KC, Weadock W, Ionita CN, Mitsouras D, Morris J, Matsumoto J, Christensen A, Liacouras P, Rybicki FJ, Sheikh A. Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Print Med 2018; 4:11. [PMID: 30649688 PMCID: PMC6251945 DOI: 10.1186/s41205-018-0030-y] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 09/19/2018] [Indexed: 02/08/2023] Open
Abstract
Medical three-dimensional (3D) printing has expanded dramatically over the past three decades with growth in both facility adoption and the variety of medical applications. Consideration for each step required to create accurate 3D printed models from medical imaging data impacts patient care and management. In this paper, a writing group representing the Radiological Society of North America Special Interest Group on 3D Printing (SIG) provides recommendations that have been vetted and voted on by the SIG active membership. This body of work includes appropriate clinical use of anatomic models 3D printed for diagnostic use in the care of patients with specific medical conditions. The recommendations provide guidance for approaches and tools in medical 3D printing, from image acquisition, segmentation of the desired anatomy intended for 3D printing, creation of a 3D-printable model, and post-processing of 3D printed anatomic models for patient care.
Collapse
Affiliation(s)
- Leonid Chepelev
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Nicole Wake
- Center for Advanced Imaging Innovation and Research (CAI2R), Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, NY USA
- Sackler Institute of Graduate Biomedical Sciences, NYU School of Medicine, New York, NY USA
| | | | - Waleed Althobaity
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Ashish Gupta
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Elsa Arribas
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - Lumarie Santiago
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO USA
| | - Kenneth C Wang
- Baltimore VA Medical Center, University of Maryland Medical Center, Baltimore, MD USA
| | - William Weadock
- Department of Radiology and Frankel Cardiovascular Center, University of Michigan, Ann Arbor, MI USA
| | - Ciprian N Ionita
- Department of Neurosurgery, State University of New York Buffalo, Buffalo, NY USA
| | - Dimitrios Mitsouras
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | | | | | - Andy Christensen
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Peter Liacouras
- 3D Medical Applications Center, Walter Reed National Military Medical Center, Washington, DC, USA
| | - Frank J Rybicki
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Adnan Sheikh
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| |
Collapse
|
34
|
Homologous Banked Bone Grafts for the Reconstruction of Large Cranial Defects in Pediatric Patients. J Craniofac Surg 2018; 29:2038-2042. [DOI: 10.1097/scs.0000000000004716] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
35
|
Autologous Bone Is Inferior to Alloplastic Cranioplasties: Safety of Autograft and Allograft Materials for Cranioplasties, a Systematic Review. World Neurosurg 2018; 117:443-452.e8. [DOI: 10.1016/j.wneu.2018.05.193] [Citation(s) in RCA: 89] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 05/25/2018] [Accepted: 05/26/2018] [Indexed: 11/19/2022]
|
36
|
|
37
|
Pakzaban P. A 3-Dimensional-Printed Spine Localizer: Introducing the Concept of Online Dissemination of Novel Surgical Instruments. Neurospine 2018; 15:242-248. [PMID: 30126266 PMCID: PMC6226123 DOI: 10.14245/ns.1836068.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/16/2018] [Indexed: 11/21/2022] Open
Abstract
Background/Aims To date, applications of 3-dimensional (3D) printing in neurosurgery have been limited to the creation of anatomical models for training and simulation, fabrication of customized implants, and production of patient-specific surgical tool guides. We aim to demonstrate a new application of this technology for the online dissemination of novel surgical instrument designs across the world.
Methods A link to a 3D printing file and instructions for assembly of a spine localizer are included in this article. This device was used to determine the optimal location of skin incision in lumbar microsurgery in 43 consecutive patients. Data regarding the accuracy of the surgeon's initial estimate of the target site based on palpation of anatomical landmarks and the accuracy of the localizer device in locating the target spine segment were prospectively collected.
Results In 35 cases (81%), the surgeon’s initial estimate of the target site was correct. In the remaining 8 cases (19%), the initial estimate was off by 1 motion segment. Inaccuracy of the surgeon’s estimate was found to be associated with a higher body mass index and the presence of transitional lumbosacral anatomy, but not with age, sex, or location of the target segment. In all patients, the location of the incision guided by the localizer was found to overlie the target segment, yielding a device accuracy of 100%. There was no need to extend the incision or modify the surgical trajectory.
Conclusion This 3D-printable localizer serves as an example of a device that can be disseminated online and printed at the point of use, thus promoting online tool-sharing by neurosurgeons.
Collapse
|
38
|
Shilo D, Emodi O, Blanc O, Noy D, Rachmiel A. Printing the Future-Updates in 3D Printing for Surgical Applications. Rambam Maimonides Med J 2018; 9:RMMJ.10343. [PMID: 30089093 PMCID: PMC6115481 DOI: 10.5041/rmmj.10343] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Three-dimensional (3D) printing is based on additive technology in which layers of materials are gradually placed to create 3D objects. The world of 3D printing is a rapidly evolving field in the medical industry as well as in most sectors of our lives. In this report we present current technological possibilities for 3D printing in the surgical field. There are different 3D printing modalities and much confusion among clinicians regarding the differences between them. Three-dimensional printing technologies can be classified based on the basic material used: solid, liquid, and powder. We describe the main printing methods from each modality and present their advantages while focusing on their applications in different fields of surgery, starting from 3D printing of models for preoperative planning up to patient-specific implants (PSI). We present the workflow of 3D printing for the different applications and our experience in 3D printing surgical guides as well as PSI. We include examples of 3D planning as well as clinical and radiological imaging of cases. Three-dimensional printing of models for preoperative planning enhances the 3D perception of the planned operation and allows for preadaptation of surgical instruments, thus shortening operation duration and improving precision. Three-dimensional printed PSI allow for accurate reconstruction of anatomic relations as well as efficiently restoring function. The application of PSI is expanding rapidly, and we will see many more innovative treatment modalities in the near future based on this technology.
Collapse
Affiliation(s)
- Dekel Shilo
- Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel
- Bruce Rappaport Faculty of Medicine, Technion–Israel Institute of Technology, Haifa, Israel
- To whom correspondence should be addressed. E-mail:
| | - Omri Emodi
- Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel
- Bruce Rappaport Faculty of Medicine, Technion–Israel Institute of Technology, Haifa, Israel
| | - Ori Blanc
- Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel
| | - Dani Noy
- Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel
- Bruce Rappaport Faculty of Medicine, Technion–Israel Institute of Technology, Haifa, Israel
| | - Adi Rachmiel
- Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel
- Bruce Rappaport Faculty of Medicine, Technion–Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
39
|
Morales-Gómez JA, Garcia-Estrada E, Leos-Bortoni JE, Delgado-Brito M, Flores-Huerta LE, De La Cruz-Arriaga AA, Torres-Díaz LJ, de León ÁRMP. Cranioplasty with a low-cost customized polymethylmethacrylate implant using a desktop 3D printer. J Neurosurg 2018; 130:1721-1727. [PMID: 29905512 DOI: 10.3171/2017.12.jns172574] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 12/11/2017] [Indexed: 01/14/2023]
Abstract
OBJECTIVE Cranioplasty implants should be widely available, low in cost, and customized or easy to mold during surgery. Although autologous bone remains the first choice for repair, it cannot always be used due to infection, fragmentation, bone resorption, or other causes, which led to use of synthetic alternatives. The most frequently used allogenic material for cranial reconstructions with long-term results is polymethylmethacrylate (PMMA). Three-dimensional printing technology has allowed the production of increasingly popular customized, prefabricated implants. The authors describe their method and experience with a customized PMMA prosthesis using a precise and reliable low-cost implant that can be customized at any institution with open-source or low-cost software and desktop 3D printers. METHODS A review of 22 consecutive patients undergoing CT-based, low-cost, customized PMMA cranioplasty over a 1-year period at a university teaching hospital was performed. Preoperative data included patient sex and age; CT modeling parameters, including the surface area of the implant (defect); reason for craniectomy; date(s) of injury and/or resections; the complexity of the defect; and associated comorbidities. Postoperative data included morbiditiy and complications, such as implant exposure, infection, hematoma, seroma, implant failure, and seizures; the cost of the implant; and cosmetic outcome. RESULTS Indications for the primary craniectomy were traumatic brain injury (16, 73%), tumor resection (3, 14%), infection (1, 4%), and vascular (2, 9%). The median interval between previous surgery and PMMA cranioplasty was 12 months. The operation time ranged from 90 to 150 minutes (mean 126 minutes). The average cranial defect measured 65.16 cm2 (range 29.31-131.06 cm2). During the recovery period, there was no sign of infection, implant rejection, or wound dehiscence, and none of the implants had to be removed over a follow-up ranging from 1 to 6 months. The aesthetic appearance of all patients was significantly improved, and the implant fit was excellent. CONCLUSIONS The use of a customized PMMA was associated with excellent patient, family, and surgeon satisfaction at follow-up at a fraction of the cost associated with commercially available implants. This technique could be an attractive option to all patients undergoing cranioplasty.
Collapse
|
40
|
Surgical results of cranioplasty using three-dimensional printing technology. Clin Neurol Neurosurg 2018; 168:118-123. [DOI: 10.1016/j.clineuro.2018.03.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 02/26/2018] [Accepted: 03/04/2018] [Indexed: 11/30/2022]
|
41
|
Frassanito P, Tamburrini G, Massimi L, Peraio S, Caldarelli M, Di Rocco C. Problems of reconstructive cranioplasty after traumatic brain injury in children. Childs Nerv Syst 2017; 33:1759-1768. [PMID: 29149388 DOI: 10.1007/s00381-017-3541-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Accepted: 07/10/2017] [Indexed: 11/29/2022]
Abstract
Cranial repair after traumatic brain injury in children is still burdened by unsolved problems and controversial issues, mainly due to the high rate of resorption of autologous bone as well as the absence of valid alternative material to replace the autologous bone. Indeed, inert biomaterials are associated to satisfactory results in the short period but bear the continuous risk of complications related to the lack of osteointegration capacity. Biomimetic materials claiming osteoconductive properties that could balance their mechanical limits seem to allow good cranial bone reconstruction. However, these results should be confirmed in the long term and in larger series. Further complicating factors that may affect cranial reconstruction after head injury should be identified in the possible associated alterations of CSF dynamics and in difficulties to manage the traumatic skin lesion and the surgical wound, which also might impact on the cranioplasty outcome. All the abovementioned considerations should be taken into account when dealing with the cranial reconstruction after decompressive craniectomy in children.
Collapse
Affiliation(s)
- Paolo Frassanito
- Pediatric Neurosurgery, Fondazione Policlinico Universitario A. Gemelli, Catholic University Medical School, Largo A. Gemelli, 8, 00168, Rome, Italy.
| | - Gianpiero Tamburrini
- Pediatric Neurosurgery, Fondazione Policlinico Universitario A. Gemelli, Catholic University Medical School, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - Luca Massimi
- Pediatric Neurosurgery, Fondazione Policlinico Universitario A. Gemelli, Catholic University Medical School, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - Simone Peraio
- Pediatric Neurosurgery, Fondazione Policlinico Universitario A. Gemelli, Catholic University Medical School, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - Massimo Caldarelli
- Pediatric Neurosurgery, Fondazione Policlinico Universitario A. Gemelli, Catholic University Medical School, Largo A. Gemelli, 8, 00168, Rome, Italy
| | - Concezio Di Rocco
- Department of Neurosurgery, International Neuroscience Institute, Hannover, Germany
| |
Collapse
|
42
|
Abdel Hay J, Smayra T, Moussa R. Customized Polymethylmethacrylate Cranioplasty Implants Using 3-Dimensional Printed Polylactic Acid Molds: Technical Note with 2 Illustrative Cases. World Neurosurg 2017; 105:971-979.e1. [DOI: 10.1016/j.wneu.2017.05.007] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Revised: 04/29/2017] [Accepted: 05/02/2017] [Indexed: 11/26/2022]
|
43
|
Guerrini F, Dallolio V, Grimod G, Cesana C, Vismara D, Franzin AB. It Is Time to Reduce Free-Hand Manipulation: Case Report of Our Proposal for an Innovative 1-Step Cranioplasty. World Neurosurg 2017; 107:1052.e7-1052.e10. [PMID: 28844924 DOI: 10.1016/j.wneu.2017.08.111] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 08/14/2017] [Accepted: 08/16/2017] [Indexed: 11/19/2022]
Abstract
BACKGROUND Cranioplasty is a well-known procedure, and autologous graft bone is usually considered the best choice in this procedure, but it cannot be used in conditions such as bone-infiltrating tumors, spheno-orbital en plaque meningiomas, and bone infections. Polymethylmethacrylate (PMMA) offers great possibility of intraoperative adaption. We describe a case of 1-step cranioplasty performed in a patient with a meningeal fibrosarcoma using a custom-made silicon mold. CASE DESCRIPTION A 48-year-old man was admitted to our department for a left temporo-parietal subcutaneous tumefaction that grew for a few months on the site of a previous osteodural decompression. After a biopsy that was diagnostic for meningeal fibrosarcoma, we planned tumor asportation, considering the bone infiltration of the tumor and the necessity of a cranioplasty. Before the intervention, we performed the craniotomy on a gypsum powder head phantom created based on a computed tomography scan. Then, using a computer-assisted design technique, a silicon mold was created and sterilized for the intervention. The edges of the preoperative simulated craniectomy were reproduced during the intervention using a rigid rail on the patient's scalp. The craniectomy was performed, and the tumor was removed. Then, a PMMA bone flap was made using a silicon mold and was fixed to the skull by miniscrews. Aesthetic results were considered excellent by the patient. CONCLUSIONS We performed a 1-step cranioplasty after resection of a meningeal fibrosarcoma that infiltrated bone with a new technique to reproduce during intervention a preoperative simulated craniectomy and a computer-assisted design PMMA flap.
Collapse
Affiliation(s)
- Francesco Guerrini
- Department of Neurosurgery, Hospital A. Manzoni, Lecco, Italy; Neurosurgical Unit, Department of Clinical Surgical Diagnostic and Pediatric Sciences, University of Pavia, Italy.
| | - Villiam Dallolio
- Department of Neurosurgery, Salus Hospital, Reggio Emilia, Italy
| | - Gianluca Grimod
- Department of Neurosurgery, Hospital A. Manzoni, Lecco, Italy
| | - Carlo Cesana
- Department of Neurosurgery, Hospital A. Manzoni, Lecco, Italy
| | - Daniela Vismara
- Department of Neurosurgery, Hospital A. Manzoni, Lecco, Italy
| | | |
Collapse
|
44
|
Jiang J, Marathe AR, Keene JC, Taylor DM. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury. J Neurosci Methods 2017; 277:21-29. [PMID: 27979758 PMCID: PMC5253247 DOI: 10.1016/j.jneumeth.2016.12.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 12/06/2016] [Accepted: 12/11/2016] [Indexed: 11/25/2022]
Abstract
BACKGROUND Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. NEW METHOD We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. RESULTS Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. COMPARISON WITH EXISTING METHODS For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. CONCLUSIONS Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models.
Collapse
Affiliation(s)
- JingLe Jiang
- Department of Neurosciences, The Cleveland Clinic, Cleveland, OH 44195, United States; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Cleveland Functional Electrical Stimulation (FES) Center of Excellence, Louis Stokes VA Medical Center, Cleveland, OH 44106, United States
| | - Amar R Marathe
- Department of Neurosciences, The Cleveland Clinic, Cleveland, OH 44195, United States; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Cleveland Functional Electrical Stimulation (FES) Center of Excellence, Louis Stokes VA Medical Center, Cleveland, OH 44106, United States; Human Research and Engineering Directorate, US Army Research Laboratory, Aberdeen Proving Ground, MD 21005, United States
| | - Jennifer C Keene
- Department of Neurosciences, The Cleveland Clinic, Cleveland, OH 44195, United States; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Cleveland Functional Electrical Stimulation (FES) Center of Excellence, Louis Stokes VA Medical Center, Cleveland, OH 44106, United States
| | - Dawn M Taylor
- Department of Neurosciences, The Cleveland Clinic, Cleveland, OH 44195, United States; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, United States; Cleveland Functional Electrical Stimulation (FES) Center of Excellence, Louis Stokes VA Medical Center, Cleveland, OH 44106, United States.
| |
Collapse
|
45
|
Hoang D, Perrault D, Stevanovic M, Ghiassi A. Surgical applications of three-dimensional printing: a review of the current literature & how to get started. ANNALS OF TRANSLATIONAL MEDICINE 2016; 4:456. [PMID: 28090512 DOI: 10.21037/atm.2016.12.18] [Citation(s) in RCA: 154] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Three dimensional (3D) printing involves a number of additive manufacturing techniques that are used to build structures from the ground up. This technology has been adapted to a wide range of surgical applications at an impressive rate. It has been used to print patient-specific anatomic models, implants, prosthetics, external fixators, splints, surgical instrumentation, and surgical cutting guides. The profound utility of this technology in surgery explains the exponential growth. It is important to learn how 3D printing has been used in surgery and how to potentially apply this technology. PubMed was searched for studies that addressed the clinical application of 3D printing in all surgical fields, yielding 442 results. Data was manually extracted from the 168 included studies. We found an exponential increase in studies addressing surgical applications for 3D printing since 2011, with the largest growth in craniofacial, oromaxillofacial, and cardiothoracic specialties. The pertinent considerations for getting started with 3D printing were identified and are discussed, including, software, printing techniques, printing materials, sterilization of printing materials, and cost and time requirements. Also, the diverse and increasing applications of 3D printing were recorded and are discussed. There is large array of potential applications for 3D printing. Decreasing cost and increasing ease of use are making this technology more available. Incorporating 3D printing into a surgical practice can be a rewarding process that yields impressive results.
Collapse
Affiliation(s)
- Don Hoang
- USC Plastic and Reconstructive Surgery, Los Angeles, CA, USA
| | - David Perrault
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Milan Stevanovic
- Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Alidad Ghiassi
- Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
46
|
Moser M, Schmid R, Schindel R, Hildebrandt G. Patient-specific polymethylmethacrylate prostheses for secondary reconstruction of large calvarial defects: A retrospective feasibility study of a new intraoperative moulding device for cranioplasty. J Craniomaxillofac Surg 2016; 45:295-303. [PMID: 28011181 DOI: 10.1016/j.jcms.2016.11.016] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 11/21/2016] [Accepted: 11/22/2016] [Indexed: 11/29/2022] Open
Abstract
PURPOSE The aim of this study was to review a new template-based technique for intraoperative patient-specific cranioplasty manufacturing (PSCM) with polymethylmethacrylate (PMMA) to cover large calvarial defects. MATERIAL AND METHODS A polypropylene foil thermoformed on a three-dimensional reprint of the calvarial defect was used as an intraoperative moulding device for PMMA between August 2012 and December 2015. Surgical and radiological data were retrospectively reviewed, and a patient questionnaire was used to assess functional and cosmetic outcome (numeric rating scale, Odom's criteria). RESULTS Seventeen patients (mean age 42.2 ± 14.5 years) received PSCM. Operating time averaged 130 ± 34 min, and the approximate blood loss was 293 ± 185 ml. Volumetric analysis revealed a lower implant volume compared to index bone (mean 66.5 vs. 72 cm3, p = 0.513), the mean difference in thickness being the lowest in the posterior parietal and pterional (0.4-0.7 mm) and the highest in the anterior-superior frontal area (1.8 mm). Cosmetic satisfaction averaged 9 ± 1.5, with 70.6% of patients judging the overall result as excellent or good and 29.4% as satisfactory. Mean follow-up was 19.5 ± 13.3 months, with an overall complication rate of 17.6%, including 11.8% surgical site infections (SSIs) and one implant removal. CONCLUSIONS Intraoperative PSCM using PMMA moulded on a thermoformed polypropylene foil leads to satisfactory outcomes. It is a safe technique with complication rates comparable but not superior to those of other alloplastic techniques, but the device has considerable production costs.
Collapse
Affiliation(s)
- Manuel Moser
- Department of Neurosurgery (Head: A. Weyerbrock), Cantonal Hospital St. Gallen, Rorschacher Strasse 95, 9007 St. Gallen, Switzerland.
| | - Raphael Schmid
- Department of Neurosurgery (Head: A. Weyerbrock), Cantonal Hospital St. Gallen, Rorschacher Strasse 95, 9007 St. Gallen, Switzerland
| | - Ralf Schindel
- Department of Neurosurgery (Head: A. Weyerbrock), Cantonal Hospital St. Gallen, Rorschacher Strasse 95, 9007 St. Gallen, Switzerland
| | - Gerhard Hildebrandt
- Department of Neurosurgery (Head: A. Weyerbrock), Cantonal Hospital St. Gallen, Rorschacher Strasse 95, 9007 St. Gallen, Switzerland
| |
Collapse
|