Britz L, Hammer M, Labuz G, Zielinska A, Jester F, Freudenberg J, Bunz U, Scholz C, Auffarth GU, Yildirim TM. Impact of Calcium and Phosphorus Levels on Optical Deterioration in Primary and Secondary Intraocular Lens Calcification. Transl Vis Sci Technol 2024; 13:18. [PMID: 39388178 PMCID: PMC11472889 DOI: 10.1167/tvst.13.10.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Accepted: 08/14/2024] [Indexed: 10/12/2024] Open
Abstract
Purpose The purpose of this study was to investigate the impact of calcium and phosphorus levels on optical deterioration in primary and secondary intraocular lens (IOL) calcification. Methods A total of 18 explanted IOLs, 10 with primary, and 8 with secondary calcification, were examined. Straylight and light loss were evaluated as predictors of optical impairment. The individual amount of calcium and phosphorus was determined using thermogravimetry followed by emission spectroscopy (ICP-OES). The relationship between calcification and optical impairment was investigated. Results Primary calcified IOLs contained significantly higher amounts of calcium and phosphorus compared to secondary calcified IOLs (calcium P < 0.02 and phosphorus P < 0.01), translating to greater light loss and significantly higher straylight mean values. In secondary calcification, light loss and straylight were highly dependent on calcium (r² = 0.90, P < 0.001 and r² = 0.70, P < 0.01) and phosphorus (r² = 0.66 and r² = 0.65, both P < 0.02), whereas these correlations were much lower in primary calcification (all r = 0.25, P > 0.05). Conclusions ICP-OES is the first methodology to precisely assess the calcium and phosphorus content in IOL calcification thus based on mass ratios allowing improved molecular characterization. Primary calcification showed higher amounts of calcium and phosphorus, translating to higher straylight and light loss and thus a higher risk for impairment of visual quality than secondary calcification. Translational Relevance This study is the first to quantify calcification and demonstrate the relationship to optical deterioration in IOLs, substantially contributing to understand how visual impairment arises in patients with calcified IOLs.
Collapse
Affiliation(s)
- Leoni Britz
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
- Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Maximilian Hammer
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
- Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Grzegorz Labuz
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
| | - Agnieszka Zielinska
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| | - Fabian Jester
- Organic Chemistry Institute, University of Heidelberg, Heidelberg, Germany
| | - Jan Freudenberg
- Organic Chemistry Institute, University of Heidelberg, Heidelberg, Germany
| | - Uwe Bunz
- Organic Chemistry Institute, University of Heidelberg, Heidelberg, Germany
| | - Christian Scholz
- Institute of Earth Sciences, University of Heidelberg, Heidelberg, Germany
| | - Gerd Uwe Auffarth
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
- Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Timur Mert Yildirim
- The David J. Apple Laboratory for Vision Research, Heidelberg, Germany
- Department of Ophthalmology, University Hospital Heidelberg, Germany
| |
Collapse
|
2
|
Buhl R, Yildirim TM, Schickhardt SK, Britz L, Lieberwirth I, Auffarth GU, Khoramnia R. Higher phosphate concentrations as in aqueous humor of diabetic patients increase intraocular lens calcification. BMC Ophthalmol 2024; 24:363. [PMID: 39179956 PMCID: PMC11342483 DOI: 10.1186/s12886-024-03553-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Accepted: 07/01/2024] [Indexed: 08/26/2024] Open
Abstract
BACKGROUND Clinical evidence suggests an association between phosphate concentrations in aqueous humor and the risk of intraocular lens (IOL) calcification. To test this hypothesis the influence of different phosphate concentrations on IOL calcification was evaluated in an in vitro electrophoresis model. METHODS 20 IOLs of two hydrophilic IOL models (CT Spheris 204, Zeiss; Lentis L-313, Oculentis) and one hydrophobic control IOL model (Clareon CNA0T0, Alcon) were exposed to physiologic and elevated phosphate concentrations, similar to diabetic aqueous humor. IOL calcification was analyzed by alizarin red staining, von Kossa staining, scanning electron microscopy, energy dispersive x-ray spectroscopy and transmission electron microscopy with electron diffraction. RESULTS Higher phosphate concentrations were associated with IOL calcification. Analyses of IOL surfaces and cross-sections documented calcification in no CT Spheris and 4 Lentis IOLs following exposure to 10 mM Na2HPO4, compared with 7 and 11 positive analyses following exposure to 14 mM Na2HPO4, respectively. Furthermore, a clear association between IOL calcification and the duration of electrophoresis was demonstrated, confirming increased phosphate concentrations and duration of exposure as risk factors of IOL calcification. CONCLUSIONS Findings suggest that higher phosphate concentrations in aqueous humor, as seen in diabetic patients, contribute to an increased IOL calcification risk, potentially explaining clinical observations showing an increased risk of IOL calcification in patients with diabetes.
Collapse
Affiliation(s)
- Rebecca Buhl
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
| | - Timur Mert Yildirim
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
| | - Sonja Katrin Schickhardt
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
| | - Leoni Britz
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
| | - Ingo Lieberwirth
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Mainz, Germany
| | - Gerd Uwe Auffarth
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
- Heidelberg University , Heidelberg, Germany.
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
| |
Collapse
|
3
|
Linaburg TJ, Cui QN, Armenti S. EVALUATION AND MANAGEMENT OF POST-OPERATIVE COMPLICATIONS FOLLOWING CATARACT EXTRACTION AND INTRAOCULAR LENS PLACEMENT. ADVANCES IN OPHTHALMOLOGY AND OPTOMETRY 2024; 9:133-151. [PMID: 39247851 PMCID: PMC11378954 DOI: 10.1016/j.yaoo.2024.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
THIS REVIEW EXPLORES POST-OPERATIVE CHALLENGES ARISING FROM CATARACT SURGERY, INCLUDING INTRAOCULAR LENS (IOL) DECENTRATION OR DISLOCATION, REFRACTIVE SURPRISES, DYSPHOTOPSIAS, AND IOL OPACIFICATIONS. IOL DECENTRATION OR DISLOCATION IS RARE, HIGHLIGHTING THE NEED FOR CAREFUL MANAGEMENT WITH MONITORING, SURGICAL REPOSITIONING OR LENS EXCHANGE TO ACHIEVE OPTIMAL VISUAL OUTCOMES. REFRACTIVE SURPRISES, ATTRIBUTED TO ERRORS IN IOL CALCULATION AND SELECTION, MAY BE MANAGED CONSERVATIVELY OR SURGICALLY, WITH THE MOST ACCURATE RESULTS ACHIEVED BY LASER VISION CORRECTION. POSITIVE AND NEGATIVE DYSPHOTOPSIAS MAY CONTINUE TO BE INTOLERABLE FOR PATIENTS, AND MAY REQUIRE LENS EXCHANGE AS WELL. IOL OPACIFICATIONS VARY BY IOL MATERIAL AND MAY BE VISUALLY SIGNIFICANT, REQUIRING LENS EXCHANGE. WE UNDERSCORE THE IMPORTANCE OF NUANCED MANAGEMENT AND PROVIDING OPTIMAL PATIENT CARE IN THE ABOVE POST-CATARACT SURGERY AND IOL IMPLANTATION COMPLICATIONS.
Collapse
Affiliation(s)
- Taylor J Linaburg
- DEPARTMENT OF OPHTHALMOLOGY, SCHEIE EYE INSTITUTE, UNIVERSITY OF PENNSYLVANIA, PHILADELPHIA, PA
| | - Qi N Cui
- DEPARTMENT OF OPHTHALMOLOGY, SCHEIE EYE INSTITUTE, UNIVERSITY OF PENNSYLVANIA, PHILADELPHIA, PA
| | - Stephen Armenti
- DEPARTMENT OF OPHTHALMOLOGY, SCHEIE EYE INSTITUTE, UNIVERSITY OF PENNSYLVANIA, PHILADELPHIA, PA
| |
Collapse
|
4
|
Morya AK, Nishant P, Ramesh PV, Sinha S, Heda A, Salodia S, Prasad R. Intraocular lens selection in diabetic patients: How to increase the odds for success. World J Diabetes 2024; 15:1199-1211. [PMID: 38983821 PMCID: PMC11229963 DOI: 10.4239/wjd.v15.i6.1199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 03/23/2024] [Accepted: 04/23/2024] [Indexed: 06/11/2024] Open
Abstract
The incidence of cataracts is significantly higher in diabetic individuals, particularly in younger age groups, with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics. Cataract surgery in diabetic patients poses many challenges: Poor epithelial healing, decreased corneal sensitivity, increased central corneal thickness, decreased endothelial cell count, variable topography, poor pupillary dilatation, anterior capsular phimosis, posterior capsular opacification (PCO), chances of progression of diabetic retinopathy (DR), zonular weakness, and vitreous prolapse and diabetic macular edema. Selection of an appropriate intraocular lens (IOL) is crucial for visual rehabilitation and monitoring DR. The choice of IOL in diabetic cataract patients is a challenging scenario. Square-edge IOLs are favored for their capacity to mitigate PCO, whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR. The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation, particularly in the presence of advanced retinopathy. Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications. Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes. This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.
Collapse
Affiliation(s)
- Arvind Kumar Morya
- Department of Ophthalmology, All India Institute of Medical Sciences, Hyderabad 508126, Telangana, India
| | - Prateek Nishant
- Department of Ophthalmology, ESIC Medical College, Patna 801113, Bihar, India
| | - Prasanna Venkatesh Ramesh
- Department of Glaucoma and Research, Mahathma Eye Hospital Private Limited, Trichy 620017, Tamil Nadu, India
| | - Sony Sinha
- Department of Ophthalmology-Vitreo-Retina, Neuro-Ophthalmology and Oculoplasty, All India Institute of Medical Sciences, Patna, Patna 801507, Bihar, India
| | - Aarti Heda
- Department of Ophthalmology, National Institute of Ophthalmology, Pune 411000, Maharashtra, India
| | - Sarika Salodia
- Department of Safety, Global Medical Safety, Lundbeck, Singapore 307591, Singapore
| | - Ripunjay Prasad
- Department of Ophthalmology, RP Eye Institute, Delhi 110001, India
| |
Collapse
|
5
|
Ucar F, Cetinkaya S, Kahraman H, Yener HI. Changes in Intraocular Lens Explantation Indications and Comparison of Various Explantation Techniques. Am J Ophthalmol 2024; 257:84-90. [PMID: 37422203 DOI: 10.1016/j.ajo.2023.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 06/06/2023] [Accepted: 06/26/2023] [Indexed: 07/10/2023]
Abstract
PURPOSE To examine the current causes of intraocular lens (IOL) explantation, compare various IOL explantation techniques, and assess the visual outcomes and complications. DESIGN Retrospective comparative case series. PARTICIPANTS A total of 175 eyes of 160 patients who underwent IOL exchange for a one-piece foldable acrylic IOL between January 2010 and March 2022 were covered by the research. Group 1 included 74 eyes from 69 patients in which the IOL was removed after being grasped, pulled, and refolded inside the main incision. Group 2 consisted of 66 eyes from 60 patients in which the IOL was removed by bisecting it, whereas group 3 included 35 eyes from 31 patients in which the IOL was removed by enlarging the main incision. MAIN OUTCOMES Surgical indications, interventions, visual outcomes and refraction, and complications. RESULTS The mean patient age was 66.1 ± 10.5 years. The mean time between primary surgery and IOL explantation was 57.0 ± 38.9 months. IOL dislocation (in 85 eyes, 49.5%) was the most common reason for IOL explantation. When the patients were examined in terms of both surgical indication groups and IOL removal techniques, corrected-distance visual acuity increased significantly in all subgroups (P < .001). The increase in astigmatism after surgery was 0.08 ± 0.13 diopters (D) in group 1, 0.09 ± 0.17 D in group 2, and 0.83 ± 0.29 D in group 3 (P < .001). CONCLUSIONS The grasp, pull, and refold technique for IOL explantation provides a simpler surgery, less complication, and good visual outcomes.
Collapse
Affiliation(s)
- Fikret Ucar
- From the Department of Ophthalmology, Konyagoz Eye Hospital (F.U., S.C., H.I.Y.).
| | - Servet Cetinkaya
- From the Department of Ophthalmology, Konyagoz Eye Hospital (F.U., S.C., H.I.Y.)
| | - Hilal Kahraman
- Department of Ophthalmology, Beyhekim Training and Research Hospital (H.K.), Konya, Turkey
| | - Halil Ibrahim Yener
- From the Department of Ophthalmology, Konyagoz Eye Hospital (F.U., S.C., H.I.Y.)
| |
Collapse
|
6
|
Britz L, Schickhardt SK, Yildirim TM, Auffarth GU, Lieberwirth I, Khoramnia R. [Hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcification]. DIE OPHTHALMOLOGIE 2023; 120:1022-1028. [PMID: 37171476 DOI: 10.1007/s00347-023-01862-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/21/2023] [Accepted: 04/06/2023] [Indexed: 05/13/2023]
Abstract
BACKGROUND Opacification through calcification of hydrophilic acrylic intraocular lenses is a serious complication of cataract surgery, which usually results in explantation of the lens. In the process of calcification, the intraocular lens material plays a crucial role: calcification only occurs in hydrophilic acrylic lenses. Hydrophobic acrylic lenses show no crystal formation within the polymer. Hydrophilic acrylic lenses from some manufacturers have hydrophobic surface properties. The question arises as to what influence these surface properties have on the risk of calcification. OBJECTIVE The present study investigated whether the hydrophobic surface properties of hydrophilic acrylic lenses can prevent calcification. MATERIAL AND METHODS Using an electrophoretic in vitro model of calcification, two hydrophilic lenses with hydrophobic surface properties were compared to two hydrophilic lenses and a hydrophobic negative control to determine the risk of calcification. The lenses were then analyzed by optical microscopy, Alizarin Red and Von Kossa staining, scanning electron microscopy (SEM) and energy dispersive X‑ray spectroscopy (EDX). RESULTS All four hydrophilic lens models showed calcification within the polymer. No difference was found between the hydrophilic lenses and the hydrophilic lenses with hydrophobic surface properties in terms of crystal formation. The hydrophobic negative control showed no calcification. CONCLUSION The investigation conducted in this study under standardized conditions could show that hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcium phosphate crystal formation within the polymer. There also is a risk of calcification in these lens models.
Collapse
Affiliation(s)
- Leoni Britz
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Sonja Katrin Schickhardt
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Timur Mert Yildirim
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Gerd Uwe Auffarth
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland
| | - Ingo Lieberwirth
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Mainz, Deutschland
| | - Ramin Khoramnia
- David J. Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, INF 400, 69120, Heidelberg, Deutschland.
| |
Collapse
|
7
|
Chamerski K, Filipecki J, Balińska A, Jeleń P, Sitarz M. Spectroscopic characterization of calcium phosphate precipitated under human eye conditions: An in vitro study. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 297:122716. [PMID: 37062117 DOI: 10.1016/j.saa.2023.122716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 03/17/2023] [Accepted: 04/04/2023] [Indexed: 05/14/2023]
Abstract
Calcification is a well-known process of calcium phosphate mineralization observed in intraocular lenses. Despite the many works conducted in this field, there is no strict explanation of the mechanisms of this process. In order to better understand the phenomenon, i.e., the mechanisms and structural conditions that promote calcification, any research observations should be conducted under conditions that best reflect those of the human eye. Taking into account the specific anatomy and physicochemical conditions of the human eye, the problem under discussion becomes difficult to solve in vitro. In the present study, calcium phosphates formed under conditions similar to those in the human eye were characterized using SEM/EDS and infrared spectroscopy. Conducted study showed the formation of white spherical precipitates, which are unstable when extracted from solution. Such precipitates were characteristic of solutions containing 1.5-3.0 mM2 of solutes. Elemental analysis showed a Ca/P ratio of 1.64-1.65, which is similar to the ratio for hydroxyapatite (1.67). Chemical structure analysis revealed the presence of broad bending and stretching bands at 475-830 cm-1 and 880-1250 cm-1, respectively, which are characteristic of PO43- groups in apatite calcium phosphates. In further analysis involving numerical fitting the bands corresponding to apatitic PO43- and indicating the presence of calcium phosphates hydration were found. The results allow the selection of immersion media for further studies involving the incubation of hydrogel intraocular lenses.
Collapse
Affiliation(s)
- Kordian Chamerski
- Department of Experimental and Applied Physics, Faculty of Science and Technology, Jan Dlugosz University in Czestochowa, Al. Armii Krajowej 13/15, 42-200 Czestochowa, Poland.
| | - Jacek Filipecki
- Department of Experimental and Applied Physics, Faculty of Science and Technology, Jan Dlugosz University in Czestochowa, Al. Armii Krajowej 13/15, 42-200 Czestochowa, Poland
| | - Agnieszka Balińska
- Institute of Chemistry, Faculty of Science and Technology, Jan Dlugosz University in Czestochowa, Al. Armii Krajowej 13/15, 42-200 Czestochowa, Poland
| | - Piotr Jeleń
- Department of Silicate Chemistry and Macromolecular Compounds, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland
| | - Maciej Sitarz
- Department of Silicate Chemistry and Macromolecular Compounds, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland
| |
Collapse
|
8
|
Britz L, Schickhardt SK, Auffarth GU, Khoramnia R. Opacification of Hydrophilic Acrylic Intraocular Lenses: Overview of Laboratory Methods for Histological Analysis and Replication of IOL Calcification. Klin Monbl Augenheilkd 2023; 240:960-970. [PMID: 37391183 DOI: 10.1055/a-2073-8526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2023]
Abstract
Opacification of intraocular lenses (IOLs) due to material changes is a serious complication that can compromise the good visual outcomes of uncomplicated cataract surgery. In hydrophobic acrylic IOLs, opacification can result from glistening formation, while in hydrophilic acrylic IOLs, there is a risk of calcification due to the formation of calcium phosphates within the polymer. Over time, various methods have been developed to investigate calcification in hydrophilic acrylic IOLs. The aim of this article is to provide an overview of standard histological staining and models used to simulate IOL calcification. Histological staining can be used to detect calcification and assess the extent of crystal formation. The development of in vivo and in vitro replication models has helped to identify the underlying pathomechanisms of calcification. In vivo models are suitable for assessing the biocompatibility of IOL materials. Bioreactors as an in vitro model can be used to investigate the kinetics of crystal formation within the polymer. The replication of IOL calcification under standardized conditions using electrophoresis allows for the comparison of different lens materials with respect to the risk of calcification. The combination of different analytical and replication methods can be used in the future to further investigate the pathomechanisms of calcium phosphate crystal formation and the influence of risk factors. This may help to prevent calcification of hydrophilic acrylic IOLs and associated explantation and complications.
Collapse
Affiliation(s)
- Leoni Britz
- Universitäts-Augenklinik, UniversitätsKlinikum Heidelberg, Deutschland
| | | | - Gerd U Auffarth
- Universitäts-Augenklinik, UniversitätsKlinikum Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Univ.-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
9
|
Morya AK, Ramesh PV, Kaur K, Gurnani B, Heda A, Bhatia K, Sinha A. Diabetes more than retinopathy, it's effect on the anterior segment of eye. World J Clin Cases 2023; 11:3736-3749. [PMID: 37383113 PMCID: PMC10294174 DOI: 10.12998/wjcc.v11.i16.3736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 04/25/2023] [Accepted: 05/06/2023] [Indexed: 06/02/2023] Open
Abstract
Diabetes mellitus (DM) is one of the chronic metabolic noncommunicable diseases that has attained worldwide epidemics. It threatens healthy life around the globe, with mild-to-severe secondary complications and leads to significant illness including nephropathy, neuropathy, retinopathy, and macrovascular abnormalities including peripheral vasculopathy, and ischaemic heart disease. Research into diabetic retinopathy (DR), which affects one-third of persons with diabetes, has made considerable strides in recent years. In addition, it can lead to several anterior segment complications such as glaucoma, cataract, cornea, conjunctiva, lacrimal glands and other ocular surface diseases. Uncontrolled DM also caused gradual damage to corneal nerves and epithelial cells, which raises the likelihood of anterior segment diseases including corneal ulcers, dry eye disease, and chronic epithelial abnormalities. Although DR and other associated ocular complications are well-known, the complexity of its aetiology and diagnosis makes therapeutic intervention challenging. Strict glycaemic control, early detection and regular screening, and meticulous management is the key to halting the progression of the disease. In this review manuscript, we aim to provide an in-depth understanding of the broad spectrum of diabetic complications in the anterior segment of the ocular tissues and illustrate the progression of diabetes and its pathophysiology, epidemiology, and prospective therapeutic targets. This first such review article will highlight the role of diagnosing and treating patients with a plethora of anterior segment diseases associated with diabetes, which are often neglected.
Collapse
Affiliation(s)
- Arvind Kumar Morya
- Department of Ophthalmology, All India Institute of Medical Sciences, Hyderabad 508126, Telangana, India
| | - Prasanna Venkatesh Ramesh
- Glaucoma and Research, Mahathma Eye Hospital Private Limited, Tennur, Trichy 620001, Tamil Nadu, India
| | - Kirandeep Kaur
- Pediatric Ophthalmology and Strabismus, Sadguru Netra Chikitsalaya, Sadguru Seva Sangh Trust, Janaki-Kund, Chitrakoot 485334, Madhya Pradesh, India
| | - Bharat Gurnani
- Cornea and Refractive Services, Sadguru Netra Chikitsalaya, Sadguru Seva Sangh Trust, Janaki- Kund, Chitrakoot 485334, Madhya Pradesh, India
| | - Aarti Heda
- Department of Ophthalmology, National Institute of Ophthalmology, Pune 411000, Maharashtra, India
| | - Karan Bhatia
- Department of Ophthalmology, Manaktala Eye and Maternity Home, Meerut 250001, Uttar Pradesh, India
| | - Aprajita Sinha
- Department of Ophthalmology, Worcestershire Acute Hospital, Worcestershire 01601, United Kingdom
| |
Collapse
|
10
|
Boix-Lemonche G, Nagymihaly RM, Lumi X, Petrovski G. The human lens is capable of trilineage differentiation towards osteo-, chondro-, and adipogenesis-a model for studying cataract pathogenesis. Front Bioeng Biotechnol 2023; 11:1164795. [PMID: 37324433 PMCID: PMC10264667 DOI: 10.3389/fbioe.2023.1164795] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 05/18/2023] [Indexed: 06/17/2023] Open
Abstract
The potential for trilineage differentiation of cells in tissues represents a model for studying disease pathogenesis and regeneration pathways. Human lens trilineage differentiation has not yet been demonstrated, and so has calcification and osteogenic differentiation of human lens epithelial cells in the whole human lens. Such changes can pose a risk for complications during cataract surgery. Human lens capsules (n = 9) from cataract patients undergoing uneventful surgery were trilineage-differentiated toward osteogenesis, chondrogenesis, and adipogenesis. Furthermore, whole human healthy lenses (n = 3) collected from cadaveric eyes were differentiated into bone and characterized by immunohistochemistry. The cells in the human lens capsules were capable of undergoing trilineage differentiation, while the whole human healthy lenses could undergo osteogenesis differentiation, expressing osteocalcin, collagen I, and pigment epithelium-derived factor. We, hereby, show an ex vivo model for cataract formation through different stages of opacification, as well as provide in vivo evidence from patients undergoing calcified lens extraction with bone-like consistency.
Collapse
Affiliation(s)
- Gerard Boix-Lemonche
- Department of Ophthalmology, Center for Eye Research and Innovative Diagnostics, Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | | | - Xhevat Lumi
- Department of Ophthalmology, Oslo University Hospital, Oslo, Norway
- Eye Hospital, University Medical Centre Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Goran Petrovski
- Department of Ophthalmology, Center for Eye Research and Innovative Diagnostics, Faculty of Medicine, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Ophthalmology, Oslo University Hospital, Oslo, Norway
- Department of Ophthalmology, University of Split School of Medicine and University Hospital Centre, Split, Croatia
| |
Collapse
|
11
|
Britz L, Schickhardt SK, Yildirim TM, Auffarth GU, Lieberwirth I, Khoramnia R. Development of a standardized in vitro model to reproduce hydrophilic acrylic intraocular lens calcification. Sci Rep 2022; 12:7685. [PMID: 35538104 PMCID: PMC9090772 DOI: 10.1038/s41598-022-11486-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 04/07/2022] [Indexed: 11/20/2022] Open
Abstract
Opacification through calcification of hydrophilic acrylic intraocular lenses (IOL) is a severe complication after cataract surgery. Causing symptoms that range from glare through to severe vision loss, the only effective therapy is explantation of the opacified IOL so far. Although IOL calcification is a well-described phenomenon, its pathogenesis is not fully understood yet. The purpose of the current study was to develop a laboratory model to replicate IOL calcification. Calcification could be reproduced using a horizontal electrophoresis and aqueous solutions of calcium chloride and disodium hydrogen phosphate. The analysis of the in vitro calcified IOLs was performed using light microscopy, Alizarin Red and Von Kossa staining, scanning electron microscopy, energy dispersive x-ray spectroscopy and electron crystallography using transmission electron microscopy and electron diffraction. The presented laboratory model could be used to identify hydrophilic IOLs that are at risk to develop calcification and to assess the influence of associated risk factors. In addition, it can serve as a research tool to further understand this pathology.
Collapse
Affiliation(s)
- Leoni Britz
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Eye Clinic Heidelberg, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Sonja Katrin Schickhardt
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Eye Clinic Heidelberg, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Timur Mert Yildirim
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Eye Clinic Heidelberg, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| | - Gerd Uwe Auffarth
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Eye Clinic Heidelberg, University of Heidelberg, INF 400, 69120, Heidelberg, Germany.
| | - Ingo Lieberwirth
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Mainz, Germany
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Eye Clinic Heidelberg, University of Heidelberg, INF 400, 69120, Heidelberg, Germany
| |
Collapse
|
12
|
Abstract
PURPOSE OF REVIEW Given the epidemiology and demographic trends of diabetes mellitus and cataracts, ophthalmologists are likely to encounter patients with both comorbidities at an increasing frequency. Patients with diabetes represent a higher risk population than healthy patients for cataract surgery. In this review, we discuss key risks and risk-mitigation practices when performing cataract surgery on these patients. RECENT FINDINGS Patients with diabetes continue to represent a high-risk surgical population: Nagar et al. suggest a dose-dependent relationship may exist between number of intravitreal injections and likelihood of posterior capsular rupture. However, novel treatments are improving outcomes for patients with diabetes. Several studies have reported intracameral phenylephrine/ketorolac may reduce the incidence of post-operative cystoid macular edema while others have discussed the efficacy of pre-treatment and post-treatment with intravitreal bevacizumab on improving cataract surgery outcomes in patients with diabetic retinopathy. Pre-operatively, ophthalmologists should perform an enhanced evaluation, consider timing and lens selection decisions, and complete any appropriate pre-operative treatment. Peri-operatively, surgeons should be aware of pupillary dilation adjustments, combination surgery options, and potential complications. Post-operatively, clinicians should address pseudophakic cystoid macular edema, diabetic macular edema, diabetic retinopathy, and posterior capsular opacification.
Collapse
Affiliation(s)
| | - Christina A Mamalis
- Cullen Eye Institute, Department of Ophthalmology, Baylor College of Medicine, 1977 Butler Blvd, Houston, TX, 77030, USA
| | - Sumitra S Khandelwal
- Cullen Eye Institute, Department of Ophthalmology, Baylor College of Medicine, 1977 Butler Blvd, Houston, TX, 77030, USA.
| |
Collapse
|
13
|
Wolf C, Gerst K, Gerst S, Priemer G. [Post-mortem clinical pathology in cattle - an additional tool for the veterinary pathologist]. Tierarztl Prax Ausg G Grosstiere Nutztiere 2021; 49:403-412. [PMID: 34861733 DOI: 10.1055/a-1593-6948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Clinical-pathologic examination of samples collected from more or less preserved body compartments during necropsy may provide important information and contribute to the list of differential diagnoses without corresponding patho-morphologic findings. It furthermore allows for diagnoses that otherwise may only be achieved clinically. Our review presents diagnostic approaches in examining aqueous humor, urine, ruminal fluid as well as other sample types characterized by a delayed onset of auto- and heterolytic artefacts. An overview is provided concerning post mortem (p. m.) sample types and collection methods with a special focus on cattle. Furthermore, clinical-pathologic methods and parameters are presented and their validity discussed. A summary of pre-analytical caveats relevant for the final interpretation of findings is made available. Based on long-term experience in p. m. clinical pathology as well as literature information we provide practical approaches for daily routine diagnostics as well as for specific case scenarios. Especially aqueous humor, ruminal fluid, and urine are easily accessible sample types. The collection of high-quality cerebrospinal fluid allows for electrolyte and metabolite analyses. Post-mortem clinical pathology may provide an indication concerning the cause of death in specific cases e. g., recumbency and death due to hypocalcemia or hypomagnesemia. This is especially relevant in cases in which ante mortem clinical pathology investigations are hindered by rapid death of the animal as well as in cases in which the gross pathology findings cannot explain the clinical findings. Post-mortem clinical pathology may also be helpful when a clinical examination of the diseased animal is hampered. During necropsy for example uremia and ketosis may be detected based on their characteristic smell; however, the use of clinical chemical analyses allows the verification by an assessment of the metabolites in these cases. Post-mortem clinical pathology may hence help in establishing a diagnosis, narrow down the list of differentials or even reveal relevant differential diagnoses for the first time during the diagnostic process. Our review does not claim to be exhaustive; however, it serves to encourage the pathologist to make use of the so far rarely employed ancillary analyses as well as to promote the collaboration between veterinary and clinical pathologists.
Collapse
Affiliation(s)
- Carola Wolf
- Landesamt für Landwirtschaft, Lebensmittelsicherheit und Fischerei Mecklenburg-Vorpommern
| | - Kirsten Gerst
- Landesamt für Landwirtschaft, Lebensmittelsicherheit und Fischerei Mecklenburg-Vorpommern
| | - Sascha Gerst
- Landesamt für Landwirtschaft, Lebensmittelsicherheit und Fischerei Mecklenburg-Vorpommern
| | - Grit Priemer
- Landesamt für Landwirtschaft, Lebensmittelsicherheit und Fischerei Mecklenburg-Vorpommern
| |
Collapse
|
14
|
Flieger J, Dolar-Szczasny J, Rejdak R, Majerek D, Tatarczak-Michalewska M, Proch J, Blicharska E, Flieger W, Baj J, Niedzielski P. The Multi-Elemental Composition of the Aqueous Humor of Patients Undergoing Cataract Surgery, Suffering from Coexisting Diabetes, Hypertension, or Diabetic Retinopathy. Int J Mol Sci 2021; 22:ijms22179413. [PMID: 34502323 PMCID: PMC8430749 DOI: 10.3390/ijms22179413] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 08/23/2021] [Accepted: 08/26/2021] [Indexed: 11/25/2022] Open
Abstract
The aim of the study was the multi-elemental analysis of aqueous humor (AH) collected from patients undergoing cataract surgery. The study included: 16 patients with age-related macular degeneration AMD (99 controls), 10 patients with retinopathy (105 controls), 61 patients with hypertension (54 controls), and 33 patients with coexisting diabetes (82 controls). The control groups were recruited from patients with a lack of co-existing disease characterizing the specified studied group. The measurements were performed by the use of inductively coupled plasma optical emission spectrometry (ICP-OES). The statistical analysis was carried out using non-parametric testing (Mann–Whitney U). The level of significance was set at p = 0.05. The data obtained revealed substantial variations in elemental composition between the test groups in comparison to the controls. However, the significant variations concerned only a few elements. The phosphorous (P) level and the ratio of P/Ca were significant in retinopathy and diabetes, whereas cobalt (0.091 ± 0.107 mg/L vs. 0.031 ± 0.075 mg/L; p = 0.004) was significant in AMD. In co-existing hypertension, the levels of tin (0.293 ± 0.409 mg/L vs. 0.152 ± 0.3 mg/L; p = 0.031), titanium (0.096 ± 0.059 mg/L vs. 0.152 ± 0.192 mg/L; p = 0.045), and ruthenium (0.035 ± 0.109 mg/L vs. 0.002 ± 0.007 mg/L; p = 0.006) varied in comparison to the controls. The study revealed inter-elemental interactions. The correlation matrices demonstrated the domination of the positive correlations, whereas negative correlations mainly concerned sodium.
Collapse
Affiliation(s)
- Jolanta Flieger
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland; (M.T.-M.); (E.B.)
- Correspondence: ; Tel.: +48-81448-7182
| | - Joanna Dolar-Szczasny
- Department of General and Pediatric Ophthalmology, Medical University of Lublin, Chmielna 1, 20-079 Lublin, Poland; (J.D.-S.); (R.R.)
| | - Robert Rejdak
- Department of General and Pediatric Ophthalmology, Medical University of Lublin, Chmielna 1, 20-079 Lublin, Poland; (J.D.-S.); (R.R.)
| | - Dariusz Majerek
- Department of Applied Mathematics, University of Technology, Nadbystrzycka 38D, 20-618 Lublin, Poland;
| | | | - Jędrzej Proch
- Faculty of Chemistry, Department of Analytical Chemistry, Adam Mickiewicz University in Poznań, 89B Umultowska Street, 61-614 Poznań, Poland; (J.P.); (P.N.)
| | - Eliza Blicharska
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland; (M.T.-M.); (E.B.)
| | - Wojciech Flieger
- Department of Anatomy, Medical University of Lublin, 20-090 Lublin, Poland; (W.F.); (J.B.)
| | - Jacek Baj
- Department of Anatomy, Medical University of Lublin, 20-090 Lublin, Poland; (W.F.); (J.B.)
| | - Przemysław Niedzielski
- Faculty of Chemistry, Department of Analytical Chemistry, Adam Mickiewicz University in Poznań, 89B Umultowska Street, 61-614 Poznań, Poland; (J.P.); (P.N.)
| |
Collapse
|
15
|
Kanclerz P, Yildirim TM, Khoramnia R. Microscopic Characteristics of Late Intraocular Lens Opacifications. Arch Pathol Lab Med 2021; 145:759-767. [PMID: 33091924 DOI: 10.5858/arpa.2019-0626-ra] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2020] [Indexed: 11/06/2022]
Abstract
CONTEXT.— The increases in overall life expectancy and in lens surgeries performed on younger patients have resulted in a significant increase in the anticipated duration of artificial intraocular lenses (IOLs) in the eye. Thus, the physicochemical properties of the IOL become a critical issue, and several types of postoperative IOL opacifications have been reported. OBJECTIVE.— To describe the microscopic characteristics of opacified IOLs. Glistenings and subsurface nanoglistenings are fluid-related phenomena developing mainly in hydrophobic acrylic IOLs and are associated with aqueous influx into the IOL matrix. Calcification presents in hydrophilic acrylic or silicone IOLs as deposits of hydroxyapatite or other phases of calcium. Snowflake degeneration is less common, and it manifests in older polymethyl methacrylate IOLs. DATA SOURCES.— PubMed and ScienceDirect databases were searched for the following keywords: intraocular lens, IOL, cataract surgery, phacoemulsification, opacification, glistening, subsurface nanoglistenings, calcification, snowflake degeneration. English-language articles published up to October 15, 2019 were included in the study. The manuscript contains mainly a literature review; however, it was supplemented with original investigations from the David J. Apple International Laboratory for Ocular Pathology. CONCLUSIONS.— Glistenings and subsurface nanoglistenings should be evaluated in a hydrated state and at room temperature; they manifest as microvacuoles sized from 1.0 to greater than 25.0 μm and less than 200 nm, respectively. Calcification deposits are situated on or underneath the surface of the IOL and can be stained with a 1% alizarin red solution or with the von Kossa method. Snowflake degeneration manifests as "particles" or "crystals," causing whitish IOL discoloration. Scanning electron microscopy or energy dispersive X-ray spectroscopy may improve the diagnostic accuracy.
Collapse
Affiliation(s)
- Piotr Kanclerz
- From the Department of Ophthalmology, Hygeia Clinic, Gdańsk, Poland (Kanclerz)
| | - Timur Mert Yildirim
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Germany (Yildirim, Khoramnia)
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Germany (Yildirim, Khoramnia)
| |
Collapse
|
16
|
Aranaz M, Costas-Rodríguez M, Lobo L, García M, González-Iglesias H, Pereiro R, Vanhaecke F. Homeostatic alterations related to total antioxidant capacity, elemental concentrations and isotopic compositions in aqueous humor of glaucoma patients. Anal Bioanal Chem 2021; 414:515-524. [PMID: 34173037 PMCID: PMC8748375 DOI: 10.1007/s00216-021-03467-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 05/04/2021] [Accepted: 06/09/2021] [Indexed: 01/05/2023]
Abstract
Glaucoma is a multifactorial eye disease, characterized by progressive optic neurodegeneration. Elevation of the intraocular pressure is the main risk factor for glaucoma and is a consequence of an imbalance in the aqueous humor hydrodynamics, the physiology of which is influenced by the homeostatic equilibrium of essential elements, oxidative stress, and antioxidants. The aim of this work was to study local alterations in glaucomatous patients from two different, but connected, points of view: (i) the total antioxidant capacity (as an indicator of oxidative damage) and (ii) the concentration of mineral elements and their isotopic composition. Such objective was pursued using aqueous humor from patients diagnosed with pseudoexfoliation glaucoma (PEXG, n = 17) and primary open-angle glaucoma (POAG, n = 5) and age-matched control subjects (n = 16). The total antioxidant capacity (TAC) was examined in both aqueous humor and 60 serum samples (n = 20 controls, n = 20 for PEXG, and n = 20 for POAG), both showing higher TAC for the glaucoma population. The concentrations of the essential mineral elements (Cu, Fe, Mg, Na, P, and Zn) and the isotopic compositions of Cu and Zn were determined in aqueous humor using single-collector and multi-collector inductively coupled plasma–mass spectrometry, respectively. Significant differences were established for Mg and P levels when comparing the results for glaucomatous patients with those for the control population (p < 0.01 and p < 0.05 for Mg and P respectively, ANOVA and Kruskal-Wallis). The Zn isotopic composition was significantly shifted from that for the control population for PEXG patients. A significant difference in the isotopic composition of Zn was also established between the PEXG and POAG glaucoma cohorts.
Collapse
Affiliation(s)
- Marta Aranaz
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006, Oviedo, Spain
| | - Marta Costas-Rodríguez
- Department of Chemistry, Atomic & Mass Spectrometry - A&MS Research Unit, Ghent University, Campus Sterre, Krijgslaan 281 - S12, 9000, Ghent, Belgium.
| | - Lara Lobo
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006, Oviedo, Spain.
| | - Montserrat García
- Instituto Oftalmológico Fernández-Vega, Avda. Fernández-Vega 34, 33012, Oviedo, Spain.,Instituto Universitario Fernández-Vega, Fundación de Investigación Oftalmológica, Universidad de Oviedo, Avda. Fernández-Vega 34, 33012, Oviedo, Spain
| | - Héctor González-Iglesias
- Instituto Oftalmológico Fernández-Vega, Avda. Fernández-Vega 34, 33012, Oviedo, Spain.,Instituto Universitario Fernández-Vega, Fundación de Investigación Oftalmológica, Universidad de Oviedo, Avda. Fernández-Vega 34, 33012, Oviedo, Spain
| | - Rosario Pereiro
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, 33006, Oviedo, Spain.,Instituto Universitario Fernández-Vega, Fundación de Investigación Oftalmológica, Universidad de Oviedo, Avda. Fernández-Vega 34, 33012, Oviedo, Spain
| | - Frank Vanhaecke
- Department of Chemistry, Atomic & Mass Spectrometry - A&MS Research Unit, Ghent University, Campus Sterre, Krijgslaan 281 - S12, 9000, Ghent, Belgium
| |
Collapse
|
17
|
Belin PJ, Kim JH, Sheikh A, Winokur J, Rhee D, Deramo V. Incidence and Risk of Scleral-Fixated Akreos (AO60) Lens Opacification: A Case Series. JOURNAL OF VITREORETINAL DISEASES 2021; 5:157-162. [PMID: 37009087 PMCID: PMC9979051 DOI: 10.1177/2474126420946605] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: Postoperative hydrophilic intraocular lens opacification can lead to decreased vision and may require intraocular lens exchange. This study aims to identify the incidence of scleral-fixated Akreos AO60’s (Bausch + Lomb) lens opacification and risk factors for this phenomenon. Methods: This is a retrospective case series of all patients who underwent scleral-fixated Akreos AO60 lens at our institution between January 1, 2015 and December 31, 2019. The following data were recorded: age, sex, medical history, indication for Akreos AO60 implantation, laterality, ocular history, previous ocular surgical procedures, subsequent intraocular surgical procedures after the Akreos implantation, lens opacification, visual significance of opacification, and Akreos explantation. Intraoperative and postoperative complications were recorded. Main outcome measures were the overall incidence of Akreos lens opacification as well as the incidence of these eyes undergoing subsequent intraocular surgery. Results: A total of 262 eyes of 257 patients underwent Akreos lens implantation. Overall, 2% (5 of 262) developed lens opacification. Two patients had Descemet stripping automated endothelial keratoplasty (DSAEK) concurrently with Akreos implantation. One patient underwent subsequent Baerveldt glaucoma implantation and DSAEK. The fourth patient had vitrectomy with sulfur hexafluoride gas followed by DSAEK. This represents a 25% (4 of 16) opacification rate among all patients who underwent DSAEK ( P ≤ .01, Fisher exact test). One patient developed opacification after undergoing 2 vitrectomies for retinal detachment in the absence of DSAEK. Conclusions: Akreos lens opacification can be visually significant and may occur after a retinal or corneal procedure that involves the use of intraocular gas or air.
Collapse
Affiliation(s)
- Peter J. Belin
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| | - Jang H. Kim
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| | - Ahmed Sheikh
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| | - Jules Winokur
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| | - David Rhee
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| | - Vincent Deramo
- Department of Ophthalmology, Northwell Health, Great Neck, NY, USA
| |
Collapse
|
18
|
Mackert M, Muth DR, Vounotrypidis E, Deger C, Goldblum D, Shajari M, Hasler PW, Priglinger S, Wolf A. Analysis of opacification patterns in intraocular lenses (IOL). BMJ Open Ophthalmol 2021; 6:e000589. [PMID: 33634210 PMCID: PMC7880112 DOI: 10.1136/bmjophth-2020-000589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 11/10/2020] [Accepted: 12/01/2020] [Indexed: 11/07/2022] Open
Abstract
Objective Intraocular lens (IOL) opacification may cause severe visual impairment. The pathogenesis remains unclear. The aim of this study was to analyse opacification patterns in different IOLs. Therefore, this multicentre, retrospective, observational study was conducted at Ludwig-Maximilians-University, Munich, Germany and University-Hospital Basel, Switzerland. Methods and analysis In this study, 75 opacified IOLs were identified and classified after extraction. Macroscopical photo documentation, light and electron microscopic analysis were done. Results 68 acrylic-hydrophilic single-piece-IOLs, 1 acrylic-hydrophilic 3-piece-IOL, 6 acrylic-hydrophobic 3-piece-IOLs were extracted. The dataset comprised IOLs known for opacification and IOLs not having been reported yet. 67 IOLs showed a fine-granular and 8 IOLs a crust-like opacification pattern. According to literature, 62 of the fine-granular opacified IOLs were graded into type 1 (processing/packaging-induced primary opacification) and 13 into type 2 (secondary opacification of unknown aetiology). The anterior surface of the IOLs was affected in all 75 IOLs, the posterior surface only in 23 cases. Of all 67 fine-granular IOLs, 43 had a central defect and 21 had a zone without opacification (clear islet). Conclusion In our series, the morphology of IOL opacification did not follow the existing pathogenetic classification that strictly discriminates between primary and secondary causes. Fine-granular IOL opacification occurs with similar patterns in both type 1 and type 2 IOL opacification, while a crust-like pattern was only detected in type 2 IOL opacifications. Consequently, susceptibility of an IOL to opacification is caused by a multifactorial combination of material and processing properties as well as individual (pathological) conditions of the patient.
Collapse
Affiliation(s)
- Marc Mackert
- Department of Ophthalmology, University of Munich, Ludwig-Maximilians-Universitat Munchen Medizinische Fakultat, Munchen, Bayern, Germany
| | - Daniel Rudolf Muth
- Department of Ophthalmology, University of Munich, Ludwig-Maximilians-Universitat Munchen Medizinische Fakultat, Munchen, Bayern, Germany
| | | | - Constanze Deger
- Department of Ophthalmology, University of Munich, Ludwig-Maximilians-Universitat Munchen Medizinische Fakultat, Munchen, Bayern, Germany
| | - David Goldblum
- Department of Ophthalmology, University Hospital Basel, Universitatsspital Basel Augenklinik, Basel, Switzerland
| | - Mehdi Shajari
- Department of Ophthalmology, University of Munich, Ludwig-Maximilians-Universitat Munchen Medizinische Fakultat, Munchen, Bayern, Germany
| | - Pascal Willy Hasler
- Department of Ophthalmology, University Hospital Basel, Universitatsspital Basel Augenklinik, Basel, Switzerland
| | - Siegfried Priglinger
- Department of Ophthalmology, University of Munich, Ludwig-Maximilians-Universitat Munchen Medizinische Fakultat, Munchen, Bayern, Germany
| | - Armin Wolf
- Ophthalmology, Universitätsklinikum Ulm, Ulm, Baden-Württemberg, Germany
| |
Collapse
|
19
|
Durr GM, Ahmed IIK. Intraocular Lens Complications: Decentration, Uveitis-Glaucoma-Hyphema Syndrome, Opacification, and Refractive Surprises. Ophthalmology 2020; 128:e186-e194. [PMID: 32652203 DOI: 10.1016/j.ophtha.2020.07.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/27/2020] [Accepted: 07/06/2020] [Indexed: 02/06/2023] Open
Abstract
As cataract surgery has evolved, intraocular lens (IOL) complications are rare. The purpose of this review was to report the incidence, diagnosis, and management of IOL decentrations, uveitis-glaucoma-hyphema (UGH) syndrome, IOL opacifications, and refractive surprises. Literature review was performed by searching PubMed, MEDLINE, EMBASE, and the Cochrane Controlled Trial Database and the reference lists of original studies as well as reviews. Intraocular lens decentrations and dislocations can appear at any time, particularly in patients with predisposing factors such as pseudoexfoliation, prior vitreoretinal surgery, or trauma. Recognizing when they require surgical intervention for UGH or to improve visual function is critical in limiting long-term sequela. Intraocular lens opacifications such as glistenings rarely require intervention, but others, such as subsurface nanoglistenings, calcifications, or discolorations, may require IOL exchange. Finally, despite our best efforts to enhance measurements and IOL calculations, refractive surprises still occur. Intraocular lens complications are uncommon with modern cataract surgery. A number of these complications require proper identification and care to optimize patient outcomes.
Collapse
Affiliation(s)
- Georges M Durr
- Department of Ophthalmology, Université de Montréal, Montréal, Canada; Department of Ophthalmology, Centre Hospitalier de l'Université de Montréal, Montréal, Canada.
| | - Iqbal Ike K Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada
| |
Collapse
|
20
|
Variation in intraocular lens calcification under different environmental conditions in eyes with supplementary sulcus-supported lenses. Am J Ophthalmol Case Rep 2020; 19:100797. [PMID: 32760851 PMCID: PMC7390754 DOI: 10.1016/j.ajoc.2020.100797] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 06/22/2020] [Indexed: 11/22/2022] Open
Abstract
Purpose Analysis of explanted intraocular lenses (IOLs) from pseudophakic eyes with supplementary sulcus-supported IOLs. Methods In this laboratory investigation, ten supplementary and capsular bag IOLs were analyzed. All lenses were received between January 2012 and March 2018. Explants were examined morphologically with histological and electron microscopic techniques and patients’ medical history was evaluated. Additionally, we used a technique new to this field: Transmission Electron Microscopy and electron diffraction pattern analysis was performed to investigate the structure of the opacifying crystals in detail. Results Eleven lenses were explanted due to IOL opacification from seven polypseudophakic eyes: In three cases the supplementary lens calcified, in three cases the capsular bag IOL (both lenses analyzed) and in one case both IOLs (only the supplementary was received). Additional surgical procedures and comorbidities included pars plana vitrectomy or Descemet stripping endothelial keratoplasty and diabetes mellitus. For each opacified lens, a varying layer of a Calcium phosphate beneath the optic surface was apparent. Crystal characterization revealed its composition to be Hydroxyapatite. Conclusions and Importance We report on a series of secondary calcification in lenses explanted from polypseudophakic eyes. In some cases, calcification occurred in the capsular bag lens, in other cases in the supplementary lens, or in both. The severity of the morphological change could be related to the comorbidities and the presence of surgery subsequent to the lens implantations. Detailed morphology of the opacifying crystals was revealed. Intraocular lenses exhibited calcification in a series of polypseudophakic eyes. Pathology occurred in the capsular bag lens, the supplementary lens, or in both. Calcification was associated with different environmental factors. Depending on the factor, morphology and pattern of the opacity differed. Transmission Electron Microscopy revealed the opacifying crystals' ultrastructure.
Collapse
|
21
|
Riau AK, Lwin NC, Gelfand L, Hu H, Liedberg B, Chodosh J, Venkatraman SS, Mehta JS. Surface modification of corneal prosthesis with nano-hydroxyapatite to enhance in vivo biointegration. Acta Biomater 2020; 107:299-312. [PMID: 31978623 DOI: 10.1016/j.actbio.2020.01.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 12/11/2022]
Abstract
The majority of clinical corneal prostheses (KPros) adopt a core-skirt configuration. This configuration is favored owing to the optic core (generally a cylindrical, acrylic-based material, such as PMMA), that not only provides a clear window for the patients' vision, but also confers resistance to biodegradability. The surrounding skirt (typically a biological material, such as corneal tissue) allows for host tissue integration. However, due to poor biointegration between the dissimilar core and skirt materials, it results in a weak adhesion at the interface, giving rise to clinical complications, such as bacterial infections in the tissue-PMMA interface and device extrusion. Here, we physically immobilized nano-hydroxyapatite (nHAp) on a PMMA cylinder via a dip-coating technique, to create a bioactive surface that improved biointegration in vivo. We established that the nHAp coating was safe and stable in the rabbit cornea over five weeks. More importantly, we found that apoptotic, wound healing and inflammatory responses to nHAp-coated PMMA were substantially milder than to non-coated PMMA. More mature collagen, similar to the non-operated cornea, was maintained in the corneal stroma adjacent to the nHAp-coated implant edge. However, around the non-coated cylinder, an abundant new and loose connective tissue formed, similar to bone tissue response to bioinert scaffolds. As a result of superior biointegration, tissue adhesion with nHAp-coated PMMA cylinders was also significantly enhanced compared to non-coated cylinders. This study set a precedent for the future application of the nHAp coating on clinical KPros. STATEMENT OF SIGNIFICANCE: Currently, all clinical corneal prostheses utilize as-manufactured, non-surface modified PMMA optic cylinder. The bioinert cylinder, however, has poor biointegration and adhesion with the surrounding biological tissue, which can give rise to postoperative complications, such as microbial invasion in the tissue-PMMA loose interface and PMMA optic cylinder extrusion. In the current study, we showed that surface modification of the PMMA cylinder with bioactive nano-hydroxyapatite (nHAp) significantly enhanced its biointegration with corneal stromal tissue in vivo. The superior biointegration of the nHAp-coated PMMA was signified by a more attenuated corneal wound healing, inflammatory and fibrotic response, and better tissue apposition, as well as a significantly improved corneal stromal tissue adhesion when compared to the non-coated PMMA.
Collapse
|
22
|
Brown RB. Diabetes, Diabetic Complications, and Phosphate Toxicity: A Scoping Review. Curr Diabetes Rev 2020; 16:674-689. [PMID: 31686640 DOI: 10.2174/1573399815666191104113236] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 10/09/2019] [Accepted: 10/28/2019] [Indexed: 02/06/2023]
Abstract
This article presents a scoping review and synthesis of research findings investigating the toxic cellular accumulation of dysregulated inorganic phosphate-phosphate toxicity-as a pathophysiological determinant of diabetes and diabetic complications. Phosphorus, an essential micronutrient, is closely linked to the cellular metabolism of glucose for energy production, and serum inorganic phosphate is often transported into cells along with glucose during insulin therapy. Mitochondrial dysfunction and apoptosis, endoplasmic reticulum stress, neuronal degeneration, and pancreatic cancer are associated with dysregulated levels of phosphate in diabetes. Ectopic calcification involving deposition of calcium-phosphate crystals is prevalent throughout diabetic complications, including vascular calcification, nephropathy, retinopathy, and bone disorders. A low-glycemic, low-phosphate dietary intervention is proposed for further investigations in the treatment and prevention of diabetes and related diabetic pathologies.
Collapse
Affiliation(s)
- Ronald B Brown
- School of Public Health and Health Systems, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
23
|
Negro Silva LF, Li C, de Seadi Pereira PJB, Tan W, Dubuc-Mageau M, Sanfacon A, Forster R, Tavcar R, Makin A, Authier S. Biochemical and Electroretinographic Characterization of the Minipig Eye in the Context of Drug Safety Investigations. Int J Toxicol 2019; 38:415-422. [PMID: 31470746 DOI: 10.1177/1091581819867929] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Minipigs are an emerging nonrodent alternative for ocular toxicology owing to anatomical similarities in the minipig eyes when compared to humans. Ocular structures and components from Göttingen minipigs were characterized and compared to species commonly used in toxicology. Ocular reference data from Göttingen minipig including intraocular pressure, vitreous electrolyte and thiol concentration, and electroretinography (ERG) data are essential to model characterization and data interpretation during drug safety assessments. Intravitreal positive control agents including gentamicin, indocyanine green, and glycine were used to demonstrate ERG alterations caused by retinal cell toxicity, light transmission obstruction, or neurotransmission interferences, respectively. Electrolyte concentrations of the aqueous and vitreous humors from Göttingen minipigs were similar to other species including humans. The reference data presented herein supports the use of the Göttingen minipig as an alternate nonrodent species in ocular toxicology.
Collapse
Affiliation(s)
| | - Christian Li
- Citoxlab North America, a Charles River Company, Laval, Quebec, Canada
| | | | - Wendy Tan
- Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Quebec, Canada
| | - Michelle Dubuc-Mageau
- Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Quebec, Canada
| | - Audrey Sanfacon
- Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Quebec, Canada
| | - Roy Forster
- Citoxlab France, a Charles River Company, Evreux, France
| | - Robert Tavcar
- Citoxlab North America, a Charles River Company, Laval, Quebec, Canada
| | - Andy Makin
- Citoxlab Denmark, a Charles River Company, Ejby, Denmark
| | - Simon Authier
- Citoxlab North America, a Charles River Company, Laval, Quebec, Canada.,Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Quebec, Canada
| |
Collapse
|
24
|
Yiğit M, Güneş A, Uğuz C, Yalçın TÖ, Tök L, Öz A, Nazıroğlu M. Effects of astaxanthin on antioxidant parameters in ARPE-19 cells on oxidative stress model. Int J Ophthalmol 2019; 12:930-935. [PMID: 31236348 DOI: 10.18240/ijo.2019.06.08] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2018] [Accepted: 04/19/2019] [Indexed: 01/10/2023] Open
Abstract
AIM To observe the protective effect of astaxanthin (AST) against hydroquinone (HQ) mediated cell death in the apoptotic cascade and evaluate intracellular Ca2+ release, caspase-3, and -9 activation, reactive oxygen species (ROS) production in ARPE-19 cells. METHODS We cultured ARPE-19 cells in special mediums and performed MTT tests to determine protective effect of AST, before exposing the cells to HQ in an incubator. We analyzed intracellular Ca2+ release experiments, mitochondrial membrane depolarization, glutathione (GSH), glutathione peroxidase (GSH-Px) and ROS experiments, and apoptosis assay. RESULTS ROS production ranges depend on the amount of cell death. We computed the correlation between ROS ranges and cell death by 20,70-dichlorofluorescein fluorescence, and Ca2+ levels by Fura-2-AM. HQ-induced cell death found out to rise ranges of caspase-3 and -9, and mitochondrial depolarization. These three steps were delayed by AST management. CONCLUSION ARPE-19 cells are avoided from HQ-induced ROS production and caspase-3 and -9 activation by AST. AST may limit the range of caspase synthesis, Ca2+ release and excess production of ROS with antiapoptotic effect. This study proposes a new therapeutic approach for the treatment of age-related macular degeneration.
Collapse
Affiliation(s)
- Musa Yiğit
- Department of Ophthalmology, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Alime Güneş
- Department of Ophthalmology, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Cihangir Uğuz
- Department of Biophysics, Faculty of Medicine, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Tök Özlem Yalçın
- Department of Ophthalmology, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Levent Tök
- Department of Ophthalmology, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Ahmi Öz
- Department of Biophysics, Faculty of Medicine, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| | - Mustafa Nazıroğlu
- Department of Biophysics, Faculty of Medicine, Süleyman Demirel University Research and Education Hospital, Çünür-Isparta 32200, Turkey
| |
Collapse
|
25
|
Kiziltoprak H, Tekin K, Inanc M, Goker YS. Cataract in diabetes mellitus. World J Diabetes 2019; 10:140-153. [PMID: 30891150 PMCID: PMC6422859 DOI: 10.4239/wjd.v10.i3.140] [Citation(s) in RCA: 147] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 03/06/2019] [Accepted: 03/08/2019] [Indexed: 02/05/2023] Open
Abstract
Diabetes mellitus (DM) is a chronic systemic disease that has increases in prevalence over time. DM can affect all ocular structures, with cataract being the most common ocular complication. Cataract is the leading cause of blindness worldwide. Due to several mechanisms, there is an increased incidence of cataract formation in the diabetic population. Advancements in technology have now made cataract surgery a common and safe procedure. However, the diabetic population is still at risk of vision-threatening complications, such as diabetic macular edema (ME), postoperative ME, diabetic retinopathy progression, and posterior capsular opacification.
Collapse
Affiliation(s)
- Hasan Kiziltoprak
- Department of Ophthalmology, University of Health Sciences, Ulucanlar Eye Training and Research Hospital, Ankara 06240, Turkey
| | - Kemal Tekin
- Ophthalmology Department, Ercis State Hospital, Van 65400, Ercis, Turkey
| | - Merve Inanc
- Ophthalmology Department, Ercis State Hospital, Van 65400, Ercis, Turkey
| | - Yasin Sakir Goker
- Department of Ophthalmology, University of Health Sciences, Ulucanlar Eye Training and Research Hospital, Ankara 06240, Turkey
| |
Collapse
|
26
|
Marcovich AL, Tandogan T, Bareket M, Eting E, Kaplan-Ashiri I, Bukelman A, Auffarth GU, Khoramnia R. Opacification of hydrophilic intraocular lenses associated with vitrectomy and injection of intraocular gas. BMJ Open Ophthalmol 2018; 3:e000157. [PMID: 30623024 PMCID: PMC6307569 DOI: 10.1136/bmjophth-2018-000157] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Objective To report 11 cases of intraocular lens (IOL) opacification after pars plana vitrectomy (PPV) involving intravitreal gas injection. Methods and analysis Eleven cases of hydrophilic IOLs that opacified following PPV with intravitreal gas injection are described. Eight IOLs were explanted and analysed by light microscopy and scanning electron microscopy. Staining with alizarin red and von Kossa stains, as well as energy dispersive X-ray spectroscopy (EDX) were performed. Three IOLs were not explanted. The surgeons attached the clinical data. Results The IOLs were hydrophilic acrylic produced by six manufacturers. Six patients underwent primarily phacoemulsification with IOL implantation. PPV with intravitreal gas injection was performed 3 months–6 years afterwards. The other five patients underwent combined phacoemulsification with IOL implantation and PPV with intravitreal gas injection. IOL opacification was recorded 1 month –6 years after PPV. In eight patients, the IOLs were explanted 1 month–9 years after opacification was noticed. In three patients, the opacified IOL was not explanted. IOLs had opacified mainly anteriorly at the pupillary entrance or capsulorhexis opening. Light microscopy demonstrated granular surface deposits on the IOLs that stained positive for calcium by alizarin red and von Kossa stains. EDX analysis of the deposits detected calcium and phosphorus. Conclusions Hydrophilic acrylic IOLs can opacify due to calcium deposition after PPV and intravitreal gas injection and may require IOL explantation. A hydrophobic IOL may be preferred when a simultaneous phacoemulsification and vitrectomy with intravitreal gas is performed.
Collapse
Affiliation(s)
- Arie L Marcovich
- Department of Ophthalmology, Kaplan Medical Center, Rehovot, Israel
| | - Tamer Tandogan
- David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Mor Bareket
- Department of Ophthalmology, Kaplan Medical Center, Rehovot, Israel
| | - Eva Eting
- Department of Ophthalmology, Assaf Harofeh Medical Center, Zeriffin, Israel
| | - Ifat Kaplan-Ashiri
- Department of Chemical Research Support, Weizmann Institute of Science, Rehovot, Israel
| | - Amir Bukelman
- Department of Ophthalmology, Kaplan Medical Center, Rehovot, Israel
| | - Gerd U Auffarth
- David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
27
|
Kelkar A, Kelkar J, Mehta H, Amoaku W. Cataract surgery in diabetes mellitus: A systematic review. Indian J Ophthalmol 2018; 66:1401-1410. [PMID: 30249823 PMCID: PMC6173035 DOI: 10.4103/ijo.ijo_1158_17] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Accepted: 05/01/2018] [Indexed: 12/20/2022] Open
Abstract
India is considered the diabetes capital of the world, and a significant proportion of patients undergoing cataract surgery are diabetic. Considering this, we reviewed the principles and guidelines of managing cataract in patients with diabetes. The preoperative, intraoperative, and postoperative factors are of paramount importance in the management of diabetic cataract patients. Particularly, the early recognition and treatment of diabetic retinopathy or maculopathy before cataract surgery influence the final visual outcome and play a major role in perioperative decision-making. Better understanding of various factors responsible for favorable outcome of cataract surgery in diabetic patients may guide us in better overalll management of these patients and optimizing the results.
Collapse
Affiliation(s)
- Aditya Kelkar
- National Institute of Ophthalmology, Pune, Maharashtra, India
| | - Jai Kelkar
- National Institute of Ophthalmology, Pune, Maharashtra, India
| | - Hetal Mehta
- National Institute of Ophthalmology, Pune, Maharashtra, India
| | - Winfried Amoaku
- Department of Ophthalmology, Nottingham University Hospitals NHS Trust, University of Nottingham, Nott Inghamshire, UK
| |
Collapse
|
28
|
Purbrick RM, Stavrakas P, Porooshani H, Patel CK, Ferguson DJ. Calcification of a Rayner Centerflex 570H hydrophilic Acrylic Intraocular Lens following Vitrectomy for Retinal Detachment: A Clinicopathologic Report. Eur J Ophthalmol 2018; 20:1082-5. [DOI: 10.1177/112067211002000611] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2010] [Indexed: 11/17/2022]
Abstract
Purpose The case of a 71-year-old man who complained of progressive, unilateral visual blurring following vitrectomy for retinal detachment due to opacification of his Rayner Centerflex 570H intraocular lens (IOL) implant is reported. Intraocular lens exchange was carried out and the explanted lens analyzed. The same model lens in his fellow eye has remained clear. Methods Clinicopathologic case report. Results Scanning electron microscopy and energy-dispersive x-ray analysis confirmed the presence of hydroxyapatite deposits within the anterior surface of the IOL. Conclusions To our knowledge, this is the first clinicopathologic case report of calcification of this model IOL in an adult patient. The sequence of events, unilaterality and pathologic findings suggest secondary calcification, which could have been related to severe postoperative inflammation and associated blood-aqueous barrier breakdown.
Collapse
Affiliation(s)
| | | | | | | | - David J.P. Ferguson
- Nuffield Department of Clinical Laboratory Sciences, Oxford University, John Radcliffe Hospital, Oxford - UK
| |
Collapse
|
29
|
Rana S, Morya RK, Malik A, Bhadada SK, Sachdeva N, Sharma G. A relationship between vitamin D, parathyroid hormone, calcium levels and lactose intolerance in type 2 diabetic patients and healthy subjects. Clin Chim Acta 2016; 462:174-177. [PMID: 27642086 DOI: 10.1016/j.cca.2016.09.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 09/15/2016] [Accepted: 09/15/2016] [Indexed: 01/15/2023]
Abstract
BACKGROUND Type 2 diabetes mellitus is chronic metabolic disorder. Common gastrointestinal symptoms in type 2 diabetic patients are flatulence, constipation and/or diarrhea. Reason for these may be lactose intolerance leading to change in vitamin D, Calcium and parathyroid hormone which further regulate bone mineralization. AIM To measure lactose intolerance, vitamin D, calcium and parathyroid hormone in type 2 diabetic patients. MATERIAL AND METHODS 150 type 2 diabetic patients attending Endocrinology Clinic in PGI, Chandigarh and 150 age and sex matched healthy controls were enrolled. Lactose intolerance was measured using non-invasive lactose breath test. 25-hydroxyvitamin D (total) and Parathyroid hormone were measured in plasma using immunoassay. Serum calcium was measured using auto analyzer. T score was recorded from DXA scan for bone mineral density measurement. RESULTS Lactose intolerance was observed significantly higher (p<0.001) diabetic patients (59.3%) as compared to controls (42%). Levels of plasma 25-OH vitamin D (total), parathyroid hormone and serum calcium were significantly lower in patients as compared to controls. Furthermore, levels of plasma 25-OH vitamin D (total), parathyroid hormone and serum calcium were more decreased in lactose intolerant diabetic patients than lactose tolerant patients. Sixty seven percent (67%) of diabetic patients suffered from osteoporosis and 20% of controls. Eighty percent (80%) diabetic patients and 16% controls with osteoporosis suffered from lactose intolerance. CONCLUSION From this study we can conclude that measurement of lactose intolerance using non-invasive lactose breath test is suggested for type 2 diabetic patients along with timely measurement of 25-OH vitamin D (total), calcium and parathyroid hormone levels.
Collapse
Affiliation(s)
- SatyaVati Rana
- Department of Gastroenterology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| | - Rajesh Kumar Morya
- Department of Gastroenterology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| | - Aastha Malik
- Department of Gastroenterology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| | - Sanjay Kumar Bhadada
- Department of Endocrinology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| | - Naresh Sachdeva
- Department of Endocrinology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| | - Gaurav Sharma
- Department of Gastroenterology, Post Graduate Institute of Medical Research and Education, Chandigarh 160012, India.
| |
Collapse
|
30
|
Rosca C, Munteanu M, Tamasoi I, Petrovic Z, Balica N, Nicula C, Cretu O. Calcification of hydrophilic acrylic intraocular lens in eyes with silicone oil tamponade - an interventional case series report. Acta Ophthalmol 2016; 94:625-7. [PMID: 26507103 DOI: 10.1111/aos.12887] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 08/17/2015] [Indexed: 11/28/2022]
Affiliation(s)
- Cosmin Rosca
- Department of Ophthalmology; ‘Victor Babes’ University of Medicine and Pharmacy Timisoara; Timisoara Timis Romania
| | - Mihnea Munteanu
- Department of Ophthalmology; ‘Victor Babes’ University of Medicine and Pharmacy Timisoara; Timisoara Timis Romania
| | - Irina Tamasoi
- Department of Ophthalmology; ‘Victor Babes’ University of Medicine and Pharmacy Timisoara; Timisoara Timis Romania
| | - Zarko Petrovic
- Department of Ophthalmology; “Đorđe Joanović” General Hospital Zrenjanin; Zrenjanin Vojvodina Serbia
| | - Nicolae Balica
- Department of ENT; ‘Victor Babes’ University of Medicine and Pharmacy Timisoara; Timisoara Timis Romania
| | - Cristina Nicula
- Department of Ophthalmology; ‘Iuliu Hatieganu’ University of Medicine and Pharmacy; Cluj-Napoca Cluj Romania
| | - Octavian Cretu
- Department of Surgery; ‘Victor Babes’ University of Medicine and Pharmacy Timisoara; Timisoara Timis Romania
| |
Collapse
|
31
|
Gartaganis SP, Prahs P, Lazari ED, Gartaganis PS, Helbig H, Koutsoukos PG. Calcification of Hydrophilic Acrylic Intraocular Lenses With a Hydrophobic Surface: Laboratory Analysis of 6 Cases. Am J Ophthalmol 2016; 168:68-77. [PMID: 27130371 DOI: 10.1016/j.ajo.2016.04.018] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Revised: 04/19/2016] [Accepted: 04/20/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE To investigate the nature and characteristic features of deposits causing opacification of intraocular lenses (IOLs) based on the examination of clinical findings using scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDX) analysis. DESIGN Retrospective, observational case series. METHODS This is a multicenter study of 6 hydrophilic acrylic IOLs (Lentis LS-502-1; Oculentis GmbH, Berlin, Germany) with a hydrophobic surface that were explanted from 5 patients because of opacification. Three patients had an uncomplicated phacoemulsification. One patient underwent combined phacoemulsification and pars plana vitrectomy for retinal detachment and later silicone oil endotamponade owing to redetachment. The last patient had a pars plana vitrectomy and silicone oil instillation combined with phacoemulsification for tractive retinal detachment and diabetic retinopathy. The explanted lenses were submitted to our laboratory and were examined by SEM and EDX in order to identify the morphologic features and the composition of the deposits. RESULTS SEM and EDX analyses confirmed the presence of calcific deposits in the interior of the opacified hydrophilic IOLs, with a pattern showing the formation of lumps on the surface. The lumps were due to subsurface formation of calcium phosphate crystalline deposits. The crystallite clusters seemed to diffuse from the IOL interior to the surface. CONCLUSIONS We demonstrated the calcification pattern of the hydrophilic IOL (Lentis LS-502-1) with a hydrophobic surface. Although hydrophilic acrylic lenses have a hydrophobic surface, the development of calcification is a possible threat initiating from the hydrophilic subsurface of the IOLs.
Collapse
|
32
|
Balogh E, Tóth A, Tolnai E, Bodó T, Bányai E, Szabó DJ, Petrovski G, Jeney V. Osteogenic differentiation of human lens epithelial cells might contribute to lens calcification. Biochim Biophys Acta Mol Basis Dis 2016; 1862:1724-31. [PMID: 27318027 DOI: 10.1016/j.bbadis.2016.06.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Revised: 05/24/2016] [Accepted: 06/14/2016] [Indexed: 01/14/2023]
Abstract
Calcification of the human lens has been described in senile cataracts and in young patients with congenital cataract or chronic uveitis. Lens calcification is also a major complication of cataract surgery and plays a role in the opacification of intraocular lenses. A cell-mediated process has been suggested in the background of lens calcification, but so far the exact mechanism remained unexplored. Lens calcification shares remarkable similarities with vascular calcification; in both pathological processes hydroxyapatite accumulates in the soft tissue. Vascular calcification is a regulated, cell-mediated process in which vascular cells undergo osteogenic differentiation. Our objective was to investigate whether human lens epithelial cells (HuLECs) can undergo osteogenic transition in vitro, and whether this process contributes to lens calcification. We used inorganic phosphate (Pi) and Ca to stimulate osteogenic differentiation of HuLECs. Osteogenic stimuli (2.5mmol/L Pi and 1.2mmol/L Ca) induced extracellular matrix mineralization and Ca deposition in HuLECs with the critical involvement of active Pi uptake. Osteogenic stimuli almost doubled mRNA expressions of osteo-/chondrogenic transcription factors Runx2 and Sox9, which was accompanied by a 1.9-fold increase in Runx2 and a 5.5-fold increase in Sox9 protein expressions. Osteogenic stimuli induced mRNA and protein expressions of alkaline phosphatase and osteocalcin in HuLEC. Ca content was higher in human cataractous lenses, compared to non-cataractous controls (n=10). Osteocalcin, an osteoblast-specific protein, was expressed in 2 out of 10 cataractous lenses. We conclude that osteogenic stimuli induce osteogenic differentiation of HuLECs and propose that this mechanism might play a role in lens calcification.
Collapse
Affiliation(s)
- Enikő Balogh
- Department of Internal Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Andrea Tóth
- Department of Internal Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Emese Tolnai
- Department of Internal Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tímea Bodó
- Department of Neurology, Bethesda Children's Hospital, Budapest, Hungary
| | - Emese Bányai
- Department of Internal Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Dóra Júlia Szabó
- Department of Ophthalmology, Faculty of Medicine, University of Szeged, Szeged, Hungary
| | - Goran Petrovski
- Department of Ophthalmology, Faculty of Medicine, University of Szeged, Szeged, Hungary; Center of Eye Research, Department of Ophthalmology, Oslo University Hospital and University of Oslo, Oslo, Norway
| | - Viktória Jeney
- Department of Internal Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
| |
Collapse
|
33
|
Calcium Hydroxyapatite Crystals in the Anterior Chamber of the Eye in a Patient With Renal Hyperparathyroidism. Cornea 2013; 32:1502-4. [DOI: 10.1097/ico.0b013e318298e344] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
34
|
Moon K, Kim KS, Kim YC. A Case of Hydrophilic Acrylic Intraocular Lens Opacification in a Patient with Proliferative Diabetic Retinopathy. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2012. [DOI: 10.3341/jkos.2012.53.8.1172] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Kun Moon
- Department of Ophthalmology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Korea
| | - Kwang Soo Kim
- Department of Ophthalmology, Keimyung University Dongsan Medical Center, Keimyung University School of Medicine, Daegu, Korea
| | - Yu Cheol Kim
- Department of Ophthalmology, Keimyung University Dongsan Medical Center, Keimyung University School of Medicine, Daegu, Korea
| |
Collapse
|
35
|
Drimtzias EG, Rokidi SG, Gartaganis SP, Koutsoukos PG. Experimental investigation on mechanism of hydrophilic acrylic intraocular lens calcification. Am J Ophthalmol 2011; 152:824-33.e1. [PMID: 21763638 DOI: 10.1016/j.ajo.2011.04.009] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 04/11/2011] [Accepted: 04/12/2011] [Indexed: 11/19/2022]
Abstract
PURPOSE To construct a model simulating intraocular lens (IOL) opacification attributable to the formation of calcium phosphate deposits and to investigate the kinetics of deposit formation. DESIGN Prospective laboratory investigation. METHODS SETTING Department of Ophthalmology, Medical School and Department of Chemical Engineering, Laboratory of Inorganic and Analytical Chemistry, University of Patras, Greece. STUDY POPULATION Three hydrophilic acrylic IOLs (26% water content) were placed inside a 10-mL double-walled thermostated reactor simulating the anterior chamber. Simulated aqueous humor was injected continuously into the reactor using a pump with variable speed. OBSERVATION PROCEDURES The observation of IOLs was carried out in situ daily by optical microscopy. Scanning electron microscopy and energy-dispersive radiographic spectroscopy were used for the identification of the morphologic features and the composition of the deposits. RESULTS The lenses were removed and inspected 5, 9, and 12 months after the initiation of the experiment. Investigation showed deposits of calcium phosphate crystallites in the interior of opacified IOLs. However, these deposits were not observed on the surface of the IOLs. CONCLUSIONS In agreement with earlier reports by our group and in the literature, IOL opacification is the result of calcification. It is suggested that the surface hydroxyl groups of the polyacrylic polymeric components of the IOLs are capable of inducing surface nucleation and crystal growth of calcium phosphates. However, most important is the finding that the calcification of IOLs is initiated from their interior through the development of sufficiently high local supersaturation, realized through the diffusion of calcium and phosphate ions.
Collapse
|
36
|
Dorozhkin SV. Calcium orthophosphates: occurrence, properties, biomineralization, pathological calcification and biomimetic applications. BIOMATTER 2011; 1:121-164. [PMID: 23507744 PMCID: PMC3549886 DOI: 10.4161/biom.18790] [Citation(s) in RCA: 150] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The present overview is intended to point the readers' attention to the important subject of calcium orthophosphates. This type of materials is of special significance for human beings, because they represent the inorganic part of major normal (bones, teeth and antlers) and pathological (i.e., those appearing due to various diseases) calcified tissues of mammals. For example, atherosclerosis results in blood vessel blockage caused by a solid composite of cholesterol with calcium orthophosphates, while dental caries and osteoporosis mean a partial decalcification of teeth and bones, respectively, that results in replacement of a less soluble and harder biological apatite by more soluble and softer calcium hydrogenphosphates. Therefore, the processes of both normal and pathological calcifications are just an in vivo crystallization of calcium orthophosphates. Similarly, dental caries and osteoporosis might be considered an in vivo dissolution of calcium orthophosphates. Thus, calcium orthophosphates hold a great significance for humankind, and in this paper, an overview on the current knowledge on this subject is provided.
Collapse
|
37
|
Jirak P, Schönherr U. Hydroview® Intraokularlinsen – Follow up 3 Jahre postoperativ. SPEKTRUM DER AUGENHEILKUNDE 2009. [DOI: 10.1007/s00717-009-0308-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
38
|
Mak ST, Wong ACM, Tsui WMS, Tse RKK. Calcification of a hydrophilic acrylic intraocular lens: clinicopathological report. J Cataract Refract Surg 2008; 34:2166-9. [PMID: 19027577 DOI: 10.1016/j.jcrs.2008.07.030] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2008] [Accepted: 07/09/2008] [Indexed: 11/26/2022]
Abstract
A 72-year-old man who had phacoemulsification with implantation of an Akreos Adapt Advanced Optics (AO) IOL in the left eye complained of blurring vision 4 months postoperatively. Multiple fine white granules were found within the IOL. Intraocular lens exchange was performed at 7 months, and the explanted IOL was sent for histopathological analysis. Diffuse fine white granules were seen within the explanted IOL material just beneath the surface; they were stained positive by alizarin red and the von Kossa method. Scanning electron microscopy confirmed the presence of calcium deposits in the IOL material. Blood and aqueous were drawn from the patient for biochemical analysis, and the results were normal. We believe this is the first clinicopathological report of calcification of the Akreos Adapt AO IOL.
Collapse
Affiliation(s)
- Shiu Ting Mak
- Department of Ophthalmology, Caritas Medical Centre, Hong Kong.
| | | | | | | |
Collapse
|
39
|
Javadi MA, Zarei-Ghanavati S. Cataracts in diabetic patients: a review article. J Ophthalmic Vis Res 2008; 3:52-65. [PMID: 23479523 PMCID: PMC3589218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The number of people with diabetes mellitus is increasing and cataracts are one of the most common causes of visual impairment in these subjects. Advances in cataract surgical techniques and instrumentation have generally improved the outcomes; however,surgery may not be safe and effective in certain individuals with pre-existing retinal pathology or limited visual potential. This review article aims to address different aspects surrounding cataracts in diabetic patients. In a computerized MEDLINE search,relevant studies were selected by two authors using the keywords "diabetes mellitus", "cataract", "diabetic retinopathy" and "diabetic maculopathy".
Collapse
|
40
|
Al-Bdour MD, Dahabreh LS. Late opacification of a hydrophilic acrylic intraocular lens. Middle East Afr J Ophthalmol 2008; 15:37-8. [PMID: 20379428 PMCID: PMC2848800 DOI: 10.4103/0974-9233.53374] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Cataract extraction and intraocular lens implantation is considered to be a safe procedure in most cases. However, the new advances in the surgical technique namely phacoemulsification and hence the increased use of foldable intraocular lenses have given rise to new complications including late opacification of intraocular lenses. In this case we report late opacification of a foldable hydrophilic acrylic intraocular lens and the surgical technique for its exchange.
Collapse
Affiliation(s)
- Muawyah D Al-Bdour
- Department of Ophthalmology, Jordan University HospitaJordan University Hospital, Amman, Jordan
| | | |
Collapse
|