1
|
Ghobakhloo S, Khoshakhlagh AH, Mostafaii GR, Carlsen L. Biomonitoring of metals in the blood and urine of waste recyclers from exposure to airborne fine particulate matter (PM 2.5). JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE & ENGINEERING 2025; 23:2. [PMID: 39583880 PMCID: PMC11582262 DOI: 10.1007/s40201-024-00924-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Accepted: 10/21/2024] [Indexed: 11/26/2024]
Abstract
This is the first systematic investigation of occupational exposure to toxic metals among waste recyclers in municipal waste recycling facilities. Concentrations of heavy metals (HMs) in the blood and urine of exposed recyclers in different jobs were compared to control groups (administrative department), identifying possible work-related and socio-demographic exposure factors. The potential relationship between HMs levels in PM2.5 and HM concentrations in the blood and urine of recyclers was studied for ten elements. Mean concentrations of HMs of recyclers were significantly higher than for the control group. Over 50% of the waste recyclers had HM levels higher than the recommended limits. The study revealed that most of the waste recyclers engaged in a minimum of three tasks, posing a challenge in establishing a correlation between specific tasks and the levels of elements monitored through biomonitoring. Co levels in blood and Fe levels in the urine of waste recyclers have a significant relationship with the increase in daily working hours. Among the variables related to the participant's demographic information, the level of education and monthly income were significantly different compared to the control group. Also, a significant correlation was found between HM levels in PM2.5 personal exposure and recyclers' urine and blood. Management controls include workflow or, in other words, alternate relocation of workers exposed to severe risks. Engineering controls such as ventilation systems, applying appropriate personal protective equipment (PPE), and risk management methods are the implementation cases to reduce exposure. Graphical abstract Supplementary Information The online version contains supplementary material available at 10.1007/s40201-024-00924-y.
Collapse
Affiliation(s)
- Safiye Ghobakhloo
- Department of Environmental Health Engineering, School of Health, Kashan University of Medical Sciences, Kashan, Iran
| | - Amir Hossein Khoshakhlagh
- Department of Occupational Health Engineering, School of Health, Kashan University of Medical Sciences, Kashan, Iran
| | - Gholam Reza Mostafaii
- Department of Environmental Health Engineering, School of Health, Kashan University of Medical Sciences, Kashan, Iran
| | | |
Collapse
|
2
|
Coskun A, Savas IN, Can O, Lippi G. From population-based to personalized laboratory medicine: continuous monitoring of individual laboratory data with wearable biosensors. Crit Rev Clin Lab Sci 2025; 62:198-227. [PMID: 39893518 DOI: 10.1080/10408363.2025.2453152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Revised: 09/28/2024] [Accepted: 01/09/2025] [Indexed: 02/04/2025]
Abstract
Monitoring individuals' laboratory data is essential for assessing their health status, evaluating the effectiveness of treatments, predicting disease prognosis and detecting subclinical conditions. Currently, monitoring is performed intermittently, measuring serum, plasma, whole blood, urine and occasionally other body fluids at predefined time intervals. The ideal monitoring approach entails continuous measurement of concentration and activity of biomolecules in all body fluids, including solid tissues. This can be achieved through the use of biosensors strategically placed at various locations on the human body where measurements are required for monitoring. High-tech wearable biosensors provide an ideal, noninvasive, and esthetically pleasing solution for monitoring individuals' laboratory data. However, despite significant advances in wearable biosensor technology, the measurement capacities and the number of different analytes that are continuously monitored in patients are not yet at the desired level. In this review, we conducted a literature search and examined: (i) an overview of the background of monitoring for personalized laboratory medicine, (ii) the body fluids and analytes used for monitoring individuals, (iii) the different types of biosensors and methods used for measuring the concentration and activity of biomolecules, and (iv) the statistical algorithms used for personalized data analysis and interpretation in monitoring and evaluation.
Collapse
Affiliation(s)
- Abdurrahman Coskun
- Department of Medical Biochemistry, School of Medicine, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Irem Nur Savas
- Department of Medical Biochemistry, School of Medicine, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Ozge Can
- Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Giuseppe Lippi
- Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy
| |
Collapse
|
3
|
Budsayapanpong V, Amornlertwatana Y, Konguthaithip G, Watcharakhom S, Intui K, Chaichana J, Khamenkhetkarn M, Jaikang C. Metabolomic insights into methamphetamine exposure: 1H-NMR-based urinary biomarker identification and pathway disruption. Chem Biol Interact 2025; 412:111449. [PMID: 40024497 DOI: 10.1016/j.cbi.2025.111449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 01/24/2025] [Accepted: 02/26/2025] [Indexed: 03/04/2025]
Affiliation(s)
- Varat Budsayapanpong
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Yutti Amornlertwatana
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Giatgong Konguthaithip
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Somlada Watcharakhom
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Kanicnan Intui
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Jatuporn Chaichana
- Toxicology Section, Regional Medical Science Center 1 Chiang Mai 191 Tumbon Don Keaw, Ampher Mae Rim, Chiang Mai, 50180, Thailand
| | - Manee Khamenkhetkarn
- Toxicology Section, Regional Medical Science Center 1 Chiang Mai 191 Tumbon Don Keaw, Ampher Mae Rim, Chiang Mai, 50180, Thailand
| | - Churdsak Jaikang
- Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand; Metabolomics Research Group for Forensic Medicine and Toxicology, Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand.
| |
Collapse
|
4
|
Van Berkel M, Beurskens-Meijerink J, Buters-Ambrosius N, Van Der Hagen E, Huisman-De Waal G, Wanten G. Accurate urine sodium measurements at home using point of care testing in patients with short bowel syndrome. Clin Nutr ESPEN 2025; 66:262-268. [PMID: 39863259 DOI: 10.1016/j.clnesp.2025.01.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 12/04/2024] [Accepted: 01/14/2025] [Indexed: 01/27/2025]
Abstract
BACKGROUND AND AIMS Measurement of the urine sodium concentration (USC) is a simple procedure that in many patients adequately indicates their hydration status. This is of particular importance in patients suffering from short bowel syndrome (SBS), who may very rapidly dehydrate and are at risk for permanently compromising their kidney function. A point of care testing (POCT) that allows reliable measurement of USC would enable these patients to effectively evaluate their sodium- and water balance in the at home setting, thereby avoiding hospital visits and delayed test results. In this study, a POCT device to assess USC was first analytically validated after which it was applied for the at home evaluation of the hydration status in patients with SBS. METHODS First, we validated the imprecision, bias and limit of quantification of USC as measured with the Fisic Medimate POCT device in comparison to an automated routine chemistry system. Next, the device was used for monitoring USC at home in 21 patients with SBS, including an evaluation of user friendliness System Usability Scale (SUS) and accuracy for detecting low sodium levels as compared to the routine chemistry system. RESULTS The imprecision of the POCT device at low USC was 6.1 %. In samples at the clinical decision threshold to identify patients at the verge of dehydration of 20 mmol/l as measured by routine chemistry USC, the POCT device demonstrated a mean estimation of USC of 20.6 mmol/l (95 % CI 18.8-22.4). Dehydration was detected with a sensitivity of 95 % when the medical decision limit for urinary sodium on the POCT device was set at a safe concentration of 30 mmol/l. Using the device was straightforward and easy to learn for patients with an overall System Usability Scale (SUS) score of 86. CONCLUSION USC measurements using this POCT device can be safely integrated into daily practice for early detection of dehydration in patients with SBS. Clear patient instructions to ensure accurate drop dispensing and a higher clinical decision threshold of USC of 30 mmol/l will allow a high sensitivity for detecting dehydration in patients with short bowel syndrome.
Collapse
Affiliation(s)
- Miranda Van Berkel
- Department of Laboratory Medicine, Radboud University Medical Center, Geert Grooteplein 10, 6500 HB, Nijmegen, the Netherlands.
| | - Judith Beurskens-Meijerink
- Department of Gastroenterology and Hepatology, Intestinal Failure Unit, Radboud University Medical Centre Nijmegen, Geert Grooteplein 10, 6500 HB, Nijmegen, the Netherlands.
| | - Nicole Buters-Ambrosius
- Department of Laboratory Medicine, Radboud University Medical Center, Geert Grooteplein 10, 6500 HB, Nijmegen, the Netherlands.
| | - Eline Van Der Hagen
- Department of Laboratory Medicine, Radboud University Medical Center, Geert Grooteplein 10, 6500 HB, Nijmegen, the Netherlands.
| | - Getty Huisman-De Waal
- Scientific Institute for Quality of Healthcare, IQ Health, Kapittelweg 54, 6525 EP, Nijmegen, the Netherlands.
| | - Geert Wanten
- Department of Gastroenterology and Hepatology, Intestinal Failure Unit, Radboud University Medical Centre Nijmegen, Geert Grooteplein 10, 6500 HB, Nijmegen, the Netherlands.
| |
Collapse
|
5
|
Sarkees E, Vuiblet V, Taha F, Piot O. Exploring the potential of Fourier transform-infrared spectroscopy of urine for non-invasive monitoring of inflammation associated with a kidney transplant. Analyst 2025; 150:1427-1435. [PMID: 40071396 DOI: 10.1039/d4an01459f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2025]
Abstract
The global rise of end-stage renal disease is leading to an increase in kidney transplants. Graft survival is dependent on the occurrence of inflammation which can lead to cases of rejection. Traditional laboratory analyses often lack accuracy, and graft biopsies - the current gold standard - are considered invasive and risky. This highlights an unmet need for innovative diagnostic and monitoring methods of graft rejection and inflammation. This study explores the potential of Fourier-transform infrared spectroscopy of fresh urine for diagnosing kidney transplant inflammation. Urine samples were collected from kidney transplant patients who were under regular surveillance. An unsupervised method of spectral data analysis, especially Uniform Manifold Approximation and Projection (UMAP), was initially employed. However, it was unable to reveal a clear distinction between control and pathological conditions. Subsequently, two machine learning models - SVM and gradient boosting - were employed to categorise participants into pathologic or control groups, achieving a diagnostic accuracy of 77.78%. This study also evaluated other factors that could affect model performance, including urine biochemical composition, type of inflammation, and patient's medication history. The inherent variability of urine, attributed to factors such as diet and medications, poses challenges to identifying robust spectroscopic markers. Nevertheless, mid-infrared spectroscopy offers a promising, non-invasive approach for diagnosing kidney transplant disorders. Further research is essential to provide more advanced prediction models and meet the criteria for potential clinical deployment.
Collapse
Affiliation(s)
- Elie Sarkees
- BioSpecT UR7506, Université de Reims Champagne-Ardenne, Reims, France.
| | - Vincent Vuiblet
- BioSpecT UR7506, Université de Reims Champagne-Ardenne, Reims, France.
- Department of Biopathology, CHU de Reims, Reims, France
- IIAS, CHU de Reims, Université de Reims Champagne-Ardenne, Reims, France
| | - Fayek Taha
- Department of Urology, CHU de Reims, Reims, France
| | - Olivier Piot
- BioSpecT UR7506, Université de Reims Champagne-Ardenne, Reims, France.
| |
Collapse
|
6
|
Vahdatiyekta P, Yrjänä V, Rosqvist E, Cetó X, Del Valle M, Huynh TP. Electrochemical Behavior of Glassy Carbon Electrodes Modified with Electropolymerized Film of N,N'-bis (2-thienylmethylene)-1,X-diaminobenzene toward Homovanillic Acid and 4-Hydroxyphenylacetic Acid. Bioelectrochemistry 2025; 165:108944. [PMID: 40020284 DOI: 10.1016/j.bioelechem.2025.108944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 02/07/2025] [Accepted: 02/16/2025] [Indexed: 03/03/2025]
Abstract
This study evaluates different electrochemical behaviors of modified glassy carbon electrodes (GCEs) for detecting urinary biomarkers related to breast cancer, namely homovanillic acid (HVA) and 4-hydroxyphenylacetic acid (4HPA). The analysis was performed in the presence of common urinary interferents, creatinine and urea. Modification of bare GCEs was done through the electropolymerization of N,N'-bis (2-thienylmethylene)-1,X-diaminobenzene (X = 2, 3, 4) isomers, so-called BTMD. The formation and characteristics of these polymeric layers were investigated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), and scanning electron microscopy (SEM). Differential pulse voltammetry (DPV) was used to measure responses of the electrodes to HVA and 4HPA, assessing their sensitivity and selectivity. Results showed that the developed electrodes effectively detected both biomarkers, with peak currents increasing proportionally to biomarker concentrations and minimal interference from creatinine and urea. The modified electrodes exhibited better linearity at higher concentrations; however, saturation was observed for 4HPA at high concentrations with the p-BTMD/GCE. Each electrode displayed unique peak current, potential, and response profiles, highlighting their promise for cross-reactive sensing systems, such as electronic tongues, to analyze complex matrices such as urine.
Collapse
Affiliation(s)
- Parastoo Vahdatiyekta
- Laboratory of Molecular Science and Engineering, Åbo Akademi University, 20500 Turku, Finland
| | - Ville Yrjänä
- Laboratory of Molecular Science and Engineering, Åbo Akademi University, 20500 Turku, Finland
| | - Emil Rosqvist
- Laboratory of Molecular Science and Engineering, Åbo Akademi University, 20500 Turku, Finland
| | - Xavier Cetó
- Sensors and Biosensors Group, Department of Chemistry, Universitat Autònoma de Barcelona, Edifici Cn, 08193 Bellaterra, Spain
| | - Manel Del Valle
- Sensors and Biosensors Group, Department of Chemistry, Universitat Autònoma de Barcelona, Edifici Cn, 08193 Bellaterra, Spain
| | - Tan-Phat Huynh
- Laboratory of Molecular Science and Engineering, Åbo Akademi University, 20500 Turku, Finland.
| |
Collapse
|
7
|
Mazaheri Z, Federico G, Koral C, Papari GP, Ullatil L, Russo P, Andreone A. Fast Detection of Uric Acid in Urine for Early Diagnosis Using THz Polarized Waves. SENSORS (BASEL, SWITZERLAND) 2025; 25:1004. [PMID: 40006233 PMCID: PMC11859403 DOI: 10.3390/s25041004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2025] [Revised: 01/30/2025] [Accepted: 02/06/2025] [Indexed: 02/27/2025]
Abstract
Towards new and improved techniques in liquid biopsy for the diagnosis of diseases, this study reports experimental evidence of a rapid and reliable method based on terahertz (THz) time-domain spectroscopic ellipsometry (TDSE) for the early diagnosis of kidney-related diseases, using the detection of uric acid (UA) content in urine. Employing a custom-built THz-TDSE system, we analyzed the absorption and dispersion response of synthetic urine samples with varying concentrations of UA. The technique provides a prompt indication of UA presence and concentration, thanks to the sensitivity of THz waves to intermolecular interactions such as hydrogen bonding. The results clearly show a linear correlation between the UA concentration and changes in the absorption spectra of urine in the frequency window 0.2-1.2 THz, with the minimum detectable UA concentration being approximately close to the upper limit of normal UA levels in urine. The increase in the absorption coefficient as a function of the UA concentration provides a means for a quantifiable measure of the UA biomarker in urine for assessing disease stage. This study proves that THz-TDSE is capable of detecting UA at concentrations relevant for early-stage diagnosis of renal diseases, with an estimated sensitivity of 0.2 g/L in the region where the material response is linear.
Collapse
Affiliation(s)
- Zahra Mazaheri
- Department of Physics “Ettore Pancini”, University of Naples Federico II, I-80126 Naples, Italy; (G.P.P.); (L.U.); (P.R.)
- Naples Unit, National Institute for Nuclear Physics (INFN), I-80126 Naples, Italy;
| | - Giorgia Federico
- Department of Molecular Medicine and Medical Biotechnology, University of Naples Federico II, I-80131 Naples, Italy;
| | - Can Koral
- Naples Unit, National Institute for Nuclear Physics (INFN), I-80126 Naples, Italy;
- Department of Health Sciences, University of Basilicata, I-85100 Potenza, Italy
| | - Gian Paolo Papari
- Department of Physics “Ettore Pancini”, University of Naples Federico II, I-80126 Naples, Italy; (G.P.P.); (L.U.); (P.R.)
- Naples Unit, National Institute for Nuclear Physics (INFN), I-80126 Naples, Italy;
| | - Lakshmi Ullatil
- Department of Physics “Ettore Pancini”, University of Naples Federico II, I-80126 Naples, Italy; (G.P.P.); (L.U.); (P.R.)
| | - Paolo Russo
- Department of Physics “Ettore Pancini”, University of Naples Federico II, I-80126 Naples, Italy; (G.P.P.); (L.U.); (P.R.)
- Naples Unit, National Institute for Nuclear Physics (INFN), I-80126 Naples, Italy;
| | - Antonello Andreone
- Department of Physics “Ettore Pancini”, University of Naples Federico II, I-80126 Naples, Italy; (G.P.P.); (L.U.); (P.R.)
- Naples Unit, National Institute for Nuclear Physics (INFN), I-80126 Naples, Italy;
| |
Collapse
|
8
|
Spinelli JC, Suleski BJ, Wright DE, Grow JL, Fagans GR, Buckley MJ, Yang DS, Yang K, Beil SM, Wallace JC, DiZoglio TS, Model JB, Love S, Macintosh DE, Scarth AP, Marrapode MT, Serviente C, Avila R, Alahmad BK, Busa MA, Wright JA, Li W, Casa DJ, Rogers JA, Lee SP, Ghaffari R, Aranyosi AJ. Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers. NPJ Digit Med 2025; 8:76. [PMID: 39893305 PMCID: PMC11787291 DOI: 10.1038/s41746-025-01466-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2024] [Accepted: 01/15/2025] [Indexed: 02/04/2025] Open
Abstract
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Da Som Yang
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | | | | | | | | | - Jeffrey B Model
- Epicore Biosystems, Inc, Cambridge, MA, USA
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | | | | | | | | | - Corinna Serviente
- Institute for Applied Life Sciences, University of Massachusetts Amherst, Amherst, MA, USA
- Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA
| | - Raudel Avila
- Department of Mechanical Engineering, Rice University, Houston, TX, USA
| | - Barrak K Alahmad
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Harvard University, Boston, MA, USA
| | - Michael A Busa
- Institute for Applied Life Sciences, University of Massachusetts Amherst, Amherst, MA, USA
- Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA
| | - John A Wright
- Epicore Biosystems, Inc, Cambridge, MA, USA
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | - Weihua Li
- Epicore Biosystems, Inc, Cambridge, MA, USA
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | - Douglas J Casa
- Department of Kinesiology, University of Connecticut, Storrs, CT, USA
| | - John A Rogers
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, USA.
- Departments of Neurological Surgery, Chemistry, Electrical Engineering and Computer Science, Northwestern University, Evanston, IL, USA.
| | - Stephen P Lee
- Epicore Biosystems, Inc, Cambridge, MA, USA.
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA.
| | - Roozbeh Ghaffari
- Epicore Biosystems, Inc, Cambridge, MA, USA.
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
| | - Alexander J Aranyosi
- Epicore Biosystems, Inc, Cambridge, MA, USA.
- Querrey-Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA.
| |
Collapse
|
9
|
Luettel DM, Terluk MR, Roh J, Weinreb NJ, Kartha RV. Emerging biomarkers in Gaucher disease. Adv Clin Chem 2025; 124:1-56. [PMID: 39818434 DOI: 10.1016/bs.acc.2024.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2025]
Abstract
Gaucher disease (GD) is a rare lysosomal disorder characterized by the accumulation of glycosphingolipids in macrophages resulting from glucocerebrosidase (GCase) deficiency. The accumulation of toxic substrates, which causes the hallmark symptoms of GD, is dependent on the extent of enzyme dysfunction. Accordingly, three distinct subtypes have been recognized, with type 1 GD (GD1) as the common and milder form, while types 2 (GD2) and 3 (GD3) are categorized as neuronopathic and severe. Manifestations variably include hepatosplenomegaly, anemia, thrombocytopenia, easy bruising, inflammation, bone pain and other skeletal pathologies, abnormal eye movements and neuropathy. Although the molecular basis of GD is relatively well understood, currently used biomarkers are nonspecific and inadequate for making finer distinctions between subtypes and in evaluating changes in disease status and guiding therapy. Thus, there is continued effort to investigate and identify potential biomarkers to improve GD diagnosis, monitoring and potential identification of novel therapeutic targets. Here, we provide a comprehensive review of emerging biomarkers in GD that can enhance current understanding and improve quality of life through better testing, disease management and treatment.
Collapse
Affiliation(s)
- Danielle M Luettel
- Center for Orphan Drug Research, Department of Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, United States
| | - Marcia R Terluk
- Center for Orphan Drug Research, Department of Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, United States
| | - Jaehyeok Roh
- Center for Orphan Drug Research, Department of Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, United States
| | - Neal J Weinreb
- Department of Human Genetics, Leonard Miller School of Medicine of University of Miami, Miami, FL, United States
| | - Reena V Kartha
- Center for Orphan Drug Research, Department of Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, United States.
| |
Collapse
|
10
|
Chauhan S, Bhandari U, Habib A. Insights into the Novel Biomarkers Expressed in Diabetic Nephropathy: Potential Clinical Applications. Curr Pharm Des 2025; 31:619-629. [PMID: 39415582 DOI: 10.2174/0113816128333694240928161703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 08/05/2024] [Accepted: 08/07/2024] [Indexed: 10/19/2024]
Abstract
Diabetic nephropathy (DN) is increasing worldwide in parallel with type 2 diabetes mellitus. Identifying diagnostic biomarkers for DN at an early stage is crucial due to the considerable societal and economic burden associated with diabetes mellitus (DM) and its risk factors. In the past, early indicators of microvascular problems, such as microalbuminuria (MA), have been used to predict the possibility of developing advanced chronic kidney disease (CKD). However, because of the incapacity of MA to appropriately estimate DN, particularly, non-albuminuric DN, additional markers have been suggested for recognizing the early renal abnormalities and structural lesions, even before MA. This study aims to assess the existing and future biomarkers used to diagnose or predict early DN. This review provides comprehensive insight into diagnostic approaches for early detection of CKD, addressing the following areas: (i) markers of glomerular damage, (ii) markers of tubular damage, (iii) oxidative stress biomarkers, (iv) inflammatory biomarkers and (v) futuristic biomarkers such as micro-ribonucleic acids (miRNAs), proteomics, metabolomics and genomics and gut microbiota. Early detection of DN may lead to improvement in clinical management and quality of life, emphasizing the importance of identifying a specific and reliable predictive biomarker. Emerging serum and urinary biomarkers offer promise for early DN diagnosis, potentially reducing prevalence and preventing progression to end-stage renal disease (ESRD). Further advancements in miRNAs, proteomics, metabolomics genomics and gut microbiota offer prospects for even earlier and more precise DN diagnosis.
Collapse
Affiliation(s)
- Shalu Chauhan
- Department of Pharmacology, School of Pharmaceutical Education and Research (SPER), Jamia Hamdard, New Delhi 110062, India
| | - Uma Bhandari
- Department of Pharmacology, School of Pharmaceutical Education and Research (SPER), Jamia Hamdard, New Delhi 110062, India
| | - Anwar Habib
- Department of Medicine, Hamdard Institute of Medical Sciences & Research (HIMSR), Jamia Hamdard, New Delhi 110062, India
| |
Collapse
|
11
|
Kuret T, Sterle I, Romih R, Veranič P. Matched serum- and urine-derived biomarkers of interstitial cystitis/bladder pain syndrome. PLoS One 2024; 19:e0309815. [PMID: 39739829 PMCID: PMC11687793 DOI: 10.1371/journal.pone.0309815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 08/19/2024] [Indexed: 01/02/2025] Open
Abstract
Setting up the correct diagnosis of interstitial cystitis/bladder pain syndrome (IC/BPS), a chronic inflammatory disease of the bladder, is a challenge, as there are neither diagnostic criteria nor reliable and non-invasive disease biomarkers available. The aim of the present study was to simultaneously determine matched serum- and urine-derived biomarkers of IC/BPS, which would provide additional insights into disease mechanisms and set the basis for further biomarker validation. Our study included 12 female patients with IC/BPS and 12 healthy controls. A total of 33 different biomarkers were measured, including cytokines and chemokines, proteins involved in extracellular matrix remodeling, adhesion molecules, growth factors, and markers of oxidative stress using enzyme linked immunoassays and multiplex technology. Heatmaps and principal component analysis based on significantly altered biomarkers, revealed urine- and serum-associated IC/BPS signatures that clearly differentiated IC/BPS patients from controls. Four biomarkers, including CCL11, BAFF, HGF and MMP9, were significantly upregulated in both serum and urine of patients with IC/BPS compared to controls. Serum levels of MMP9 were associated with disease severity and could distinguish well between IC/BPS patients with and without Hunner's lesions. Systemic levels of MMP9 can therefore mirror the local pathology within the bladders of IC/BPS patients, and MMP9 may prove to be a useful target for the development of novel therapeutic interventions. Utilizing a comprehensive panel of both urine and serum biomarkers, identified here, holds promise for disease detection in IC/BPS patients.
Collapse
Affiliation(s)
- Tadeja Kuret
- Institute of Cell Biology, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Igor Sterle
- Department of Urology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Rok Romih
- Institute of Cell Biology, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Peter Veranič
- Institute of Cell Biology, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
12
|
Kim TH, Oh GW, Heo SY, Heo SJ, Kim YM, Lee DS, Kang HW, Kim HW, Lee B, Choi IW, Park WS, Jung WK. 3D-printed polycaprolactone/collagen/alginate scaffold incorporating phlorotannin for bone tissue regeneration: Assessment of sub-chronic toxicity. Int J Biol Macromol 2024; 282:137480. [PMID: 39522906 DOI: 10.1016/j.ijbiomac.2024.137480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 10/27/2024] [Accepted: 11/08/2024] [Indexed: 11/16/2024]
Abstract
The development of effective scaffolds for bone regeneration is crucial given the increasing demand for innovative solutions to address bone defects and enhance healing process. In this study, a polycaprolactone/fish collagen/alginate (P/FC/A) 3D scaffold incorporating phlorotannin was developed to promote bone tissue regeneration. While the efficacy of the P/FC/A scaffold has been demonstrated through in vitro and in vivo experiments, its sub-chronic toxicity in animal models remains understudied, raising concerns regarding its safety in clinical application. Therefore, this study assessed the sub-chronic toxicity of the P/FC/A scaffold over 12 week using a New Zealand White rabbit model. Our results indicate no significant adverse effects in the group exposed to the P/FC/A scaffold compared with the negative control group implanted with a high-density polyethylene scaffold. These findings underscore the non-toxicity and safety profile of the P/FC/A scaffold, further supporting its potential suitability for clinical use in bone regeneration.
Collapse
Affiliation(s)
- Tae-Hee Kim
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea
| | - Gun-Woo Oh
- National Marine Biodiversity Institute of Korea, Seochun, Chungcheongnam-do 33662, Republic of Korea
| | - Seong-Yeong Heo
- Jeju Bio Research Center, Korea Institute of Ocean Science and Technology (KIOST), Jeju 63349, Republic of Korea; Department of Marine Technology & Convergence Engineering (Marine Biotechnology), University of Science and Technology (UST), Daejeon 34113, Republic of Korea
| | - Soo-Jin Heo
- Jeju Bio Research Center, Korea Institute of Ocean Science and Technology (KIOST), Jeju 63349, Republic of Korea; Department of Marine Technology & Convergence Engineering (Marine Biotechnology), University of Science and Technology (UST), Daejeon 34113, Republic of Korea
| | - Young-Mog Kim
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea; Department of Food Science and Technology, Pukyong National University, Busan 48513, Republic of Korea
| | - Dae-Sung Lee
- National Marine Biodiversity Institute of Korea, Seochun, Chungcheongnam-do 33662, Republic of Korea
| | - Hyun Wook Kang
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea; Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence and New-senior Healthcare Innovation Center (BK21 Plus), Busan 48513, Republic of Korea
| | - Hyun-Woo Kim
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea; Department of Marine Biology, Pukyong National University, Busan 48513, Republic of Korea
| | - Bongii Lee
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea; Department of Food Science and Nutrition, Pukyong National University, Busan 48513, Republic of Korea
| | - Il-Whan Choi
- Department of Microbiology and Immunology, College of Medicine, Inje University, Busan 47392, Republic of Korea
| | - Won Sun Park
- Department of Physiology, Kangwon National University School of Medicine, Chuncheon 24341, Republic of Korea
| | - Won-Kyo Jung
- Research Center for Marine-Integrated Bionics Technology, Pukyong National University, Busan 48513, Republic of Korea; Marine Integrated Biomedical Technology Center, The National Key Research Institutes in Universities, Pukyong National University, Busan 48513, Republic of Korea; Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence and New-senior Healthcare Innovation Center (BK21 Plus), Busan 48513, Republic of Korea.
| |
Collapse
|
13
|
Maden M, Ider M, Or ME, Dokuzeylül B, Gülersoy E, Kılıçkaya MC, Bilgiç B, Durgut MK, İzmirli S, Iyigün SS, Telci DZ, Naseri A. The clinical efficacy of cGMP-specific sildenafil on mitochondrial biogenesis induction and renal damage in cats with acute on chronic kidney disease. BMC Vet Res 2024; 20:499. [PMID: 39478527 PMCID: PMC11526613 DOI: 10.1186/s12917-024-04345-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Accepted: 10/22/2024] [Indexed: 11/02/2024] Open
Abstract
BACKGROUND Mitochondrial biogenesis (MB) induction has recently emerged as potential therapeutic approaches in kidney pathology and the mitochondria-targeted therapies should be investigated to improve treatment of animals with kidney diseases. This study aimed to investigate the effects of MB induction with sildenafil citrate on the cGMP/NO pathway, glomerular filtration, and reduction of kidney damage and fibrosis (TGF-β/SMAD pathway) in cats with acute on chronic kidney disease (ACKD). Thirty-three cats were divided into the non-azotemic (healthy) group (n:8) and the ACKD group (n:25), comprising different breeds, sexes, and ages. Sildenafil citrate was administered to the non-azotemic and ACKD groups (2.5 mg/kg, PO, q12 hours) for 30 days. Serum and urine NO, MDA, NGAL, KIM-1, TGF-β1, IL-18, FGF 23, PGC-1α and cGMP concentrations were measured. RESULTS Serum cGMP concentrations increased (P < 0.05) in the non-azotemic group during the 2nd (median 475.99 pmol/mL) and 3rd (median 405.01 pmol/mL) weeks of the study, whereas serum cGMP concentrations decreased in the ACKD group during the 4th(median 188.52 pmol/mL) week compared to the non-azotemic group (P < 0.05). No difference was observed in serum biomarker concentrations except NO, which increased in the 4th week (P < 0.05). The urinary concentrations of NO, MDA, PGC-1α, TGF-β1, NGAL, KIM-1, IL-18, and FGF 23 in the ACKD group were found to be higher compared to those in the non-azotemic group from the 1st to the 4th week (P < 0.05). In the ACKD group, the urine PGC-1α concentration in the 2nd (median 6.10 ng/mL) week was lower compared to that in the 0 and 1st (median 7.65 and 7.21 ng/mL, respectively) week, and the NO concentration in the 3rd (median 28.94 µmol/mL) week was lower than that in the 0th (median 37.43 µmol/mL) week (P < 0.05). CONCLUSIONS While sildenafil citrate has been determined to induce a low level of MB and to have a beneficial effect on glomerular filtration, it is observed to be ineffective in mitigating renal damage and fibrosis via the TGF-β/SMAD pathway in cats with ACKD.
Collapse
Affiliation(s)
- Mehmet Maden
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye.
| | - Merve Ider
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye
| | - Mehmet Erman Or
- Faculty of Veterinary Medicine, Internal Medicine Department, Istanbul University-Cerrahpasa, Istanbul, Türkiye
| | - Banu Dokuzeylül
- Faculty of Veterinary Medicine, Internal Medicine Department, Istanbul University-Cerrahpasa, Istanbul, Türkiye
| | - Erdem Gülersoy
- Faculty of Veterinary Medicine, Department of Internal Medicine, Harran University, Şanlıurfa, Türkiye
| | - Merve Cansu Kılıçkaya
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye
| | - Bengü Bilgiç
- Faculty of Veterinary Medicine, Internal Medicine Department, Istanbul University-Cerrahpasa, Istanbul, Türkiye
| | - Murat Kaan Durgut
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye
| | - Semih İzmirli
- Faculty of Veterinary Medicine, Internal Medicine Department, Istanbul University-Cerrahpasa, Istanbul, Türkiye
| | - Suleyman Serhat Iyigün
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye
| | - Deniz Zeynep Telci
- Faculty of Veterinary Medicine, Internal Medicine Department, Istanbul University-Cerrahpasa, Istanbul, Türkiye
| | - Amir Naseri
- Faculty of Veterinary Medicine, Department of Internal Medicine, Selcuk University, Konya, 42250, Türkiye
| |
Collapse
|
14
|
Miri A, Orouji A, Hormozi-Nezhad MR. Etched-suppressed gold nanorods providing highly distinctive plasmonic patterns: Towards multiplex analysis of neuroblastoma biomarkers. Anal Chim Acta 2024; 1325:343119. [PMID: 39244305 DOI: 10.1016/j.aca.2024.343119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Revised: 08/03/2024] [Accepted: 08/15/2024] [Indexed: 09/09/2024]
Abstract
BACKGROUND On-site monitoring of vanillylmandelic acid (VMA), homovanillic acid (HVA), and dopamine (DA) as key diagnostic biomarkers for a wide range of neurological disorders holds utmost significance in clinical settings. Numerous colorimetric sensors with mechanistic approaches based on aggregation or silver metallization have been introduced for this purpose. However, these mechanisms have drawbacks, such as sensitivity to environmental factors and probe toxicity. Therefore, there is a great demand for a robust yet non-toxic colorimetric sensor that employs a novel route to monitor these biomarkers effectively. RESULTS Here, we present a single-component multi-colorimetric probe based on the controllable etching suppression of gold nanorods (AuNRs) upon exposure to the mild etchant N-bromosuccinimide (NBS), designed to accurately detect and discriminate VMA, HVA, DA, and their corresponding mixtures, i.e. , VMA HVA, VMA:DA, HVA:DA, and VMA:HVA:DA. To enhance the sensitivity and automation capabilities of the designed multi-colorimetric sensor, two machine learning techniques were employed: linear discriminant analysis (LDA) for the qualitative classification and partial least-squares regression (PLSR) for the quantitative analysis of pure biomarkers and their mixtures. The outcomes revealed a high correlation between measured and predicted values, covering a linear range of 0.8-25, 1.2-25, and 2.7-100 μmol L-1, with remarkably low detection limits of 0.260, 0.397, and 0.913 μmol L-1 for VMA, HVA, and DA, respectively. Lastly, the performance of the probe was validated by successfully detecting the neuroblastoma biomarker VMA:HVA in human urine. SIGNIFICANCE Our designed multi-colorimetric probe introduces a rapid, cost-effective, user-friendly, non-toxic, and non-invasive approach to detecting and discriminating not only the pure biomarkers but also their corresponding binary and ternary mixtures. The distinctive response profiles produced by the probe in the presence of different mixture ratios can indicate various disease states in patients, which is highly crucial in clinical diagnostics.
Collapse
Affiliation(s)
- Amirhosein Miri
- Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran
| | - Afsaneh Orouji
- Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran
| | - Mohammad Reza Hormozi-Nezhad
- Department of Chemistry, Sharif University of Technology, Tehran, 111559516, Iran; Institute for Nanoscience and Nanotechnology, Sharif University of Technology, Tehran, 11155-9516, Iran.
| |
Collapse
|
15
|
Midzi H, Naicker T, Vengesai A, Mabaya L, Muchesa P, Mduluza-Jokonya TL, Katerere AG, Kapanga D, Kasambala M, Mutapi F, Mduluza T. Assessment of urine metabolite biomarkers for the detection of S. haematobium infection in pre-school aged children in a rural community in Zimbabwe. Acta Trop 2024; 258:107327. [PMID: 39127139 DOI: 10.1016/j.actatropica.2024.107327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 07/15/2024] [Accepted: 07/16/2024] [Indexed: 08/12/2024]
Abstract
BACKGROUND Early diagnosis of urogenital schistosomiasis is key to its control and elimination. The current gold standard microscopic examination techniques lack sensitivity in detecting light Schistosomiasis infections in pre-school aged children thus it is urgent to develop diagnostic tools that may be integrated into control programs. In this study, we evaluated the diagnostic performance of urine metabolite biomarkers using a chemical reagent strip in the detection of S. haematobium infection in pre-school aged children. METHODS A case-control study was conducted involving 82 pre-school aged children that were age and sex matched. Urine samples were collected for 3 consecutive days and were evaluated using urine filtration gold techniques as the gold standard method. The samples were simultaneously measured for metabolite biomarkers specifically haematuria, proteins, ketones, nitrites, glucose, bilirubin and urobilinogen using chemical reagent strips. Pearson correlation test was used to measure the relationship between S. haematobium infection and the urine metabolite biomarkers. RESULTS The diagnostic performance of urine biomarkers were correlated with the microscopic examination urine filtration technique. Haematuria (r = 0.592, p = 0.0001) and proteinuria (r = 0.448, p = 0.0001) were correlated to S. haematobium infection. Negative correlations with p > 0.05 were recorded for ketones and urobilinogen. Highest sensitivity was 65.9 % (CI, 49.4 - 79.9) for haematuria whilst protein (albumin) biomarker had a lower specificity value of 43.9 % (28.5 - 60.3). Inversely, highest sensitivity was 87.8 % (73.8 - 95.9) for proteinuria whilst haematuria had a lower sensitivity value of 82.9 % (67.9 - 92.8). The positive predictive values ranged from 57.7 % (41.6 - 72.2) to 79.4 % (65.5 - 88.7) whereas negative predictive values ranged from 70.8 % (60.8 - 79.2) to 52.0 % (48.7 - 55.3). With respect to diagnostic efficiency, haematuria had a fair diagnostic performance with an area under the curve of 0.76 followed by proteinuria with proteinuria whilst the remaining metabolites fail discriminating ability with an area under the curve of <0.5. CONCLUSION Although haematuria and protein biomarkers in urine are moderately sensitive and specific, they are important morbidity indicators of urogenital schistosomiasis in pre-school aged that may be utilised during screening in schistosomiasis control programs. We recommend comprehensive analysis of biomarkers using metabolomics techniques to identify novel urine biomarkers.
Collapse
Affiliation(s)
- Herald Midzi
- Department of Biochemistry and Biotechnology, University of Zimbabwe, Harare, Zimbabwe; Optics & Imaging, Doris Duke Medical Research Institute, College of Health Sciences, University of KwaZulu-Natal, KwaZulu-Natal, South Africa.
| | - Thajasvarie Naicker
- Optics & Imaging, Doris Duke Medical Research Institute, College of Health Sciences, University of KwaZulu-Natal, KwaZulu-Natal, South Africa
| | - Arthur Vengesai
- Faculty of Medicine and Health Sciences, Department of Biochemistry, Midlands State University, Gweru, Zimbabwe
| | - Lucy Mabaya
- Midlands State University, National Pathology Research and Diagnostic Centre, Gweru, Zimbabwe
| | - Petros Muchesa
- Water and Health Research Centre, University of Johannesburg, South Africa
| | - Tariro L Mduluza-Jokonya
- Optics & Imaging, Doris Duke Medical Research Institute, College of Health Sciences, University of KwaZulu-Natal, KwaZulu-Natal, South Africa; Faculty of Medicine and Health Science, University of Zimbabwe, Harare, Zimbabwe
| | | | - Donald Kapanga
- Midlands State University, National Pathology Research and Diagnostic Centre, Gweru, Zimbabwe
| | - Maritha Kasambala
- Department of Biological Sciences and Ecology, University of Zimbabwe, Harare, Zimbabwe
| | - Francisca Mutapi
- Ashworth Laboratories, Institute for Immunology and Infection Research and Centre for Immunity, Infection and Evolution, School of Biological Sciences, University of Edinburgh, Edinburgh, Scotland , United Kingdom
| | - Takafira Mduluza
- Department of Biochemistry and Biotechnology, University of Zimbabwe, Harare, Zimbabwe
| |
Collapse
|
16
|
Mattoo TK, Spencer JD. Biomarkers for urinary tract infection: present and future perspectives. Pediatr Nephrol 2024; 39:2833-2844. [PMID: 38483594 DOI: 10.1007/s00467-024-06321-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 02/07/2024] [Accepted: 02/07/2024] [Indexed: 08/28/2024]
Abstract
A prompt diagnosis of urinary tract infection (UTI) is necessary to minimize its symptoms and limit sequelae. The current UTI screening by urine test strip analysis and microscopic examination has suboptimal diagnostic accuracy. A definitive diagnosis of UTI by urine culture takes two to three days for the results. These limitations necessitate a need for better biomarkers for the diagnosis and subsequent management of UTI in children. Here, we review the value of currently available UTI biomarkers and highlight the potential of emerging biomarkers that can facilitate a more rapid and accurate UTI diagnosis. Of the newer UTI biomarkers, the most promising are blood procalcitonin (PCT) and urinary neutrophil gelatinase-associated lipocalin (NGAL). PCT can provide diagnostic benefits and should be considered in patients who have a blood test for other reasons. NGAL, which is on the threshold of clinical care, needs more research to address its scope and utilization, including point-of-care application. Employment of these and other biomarkers may ultimately improve UTI diagnosis, guide UTI therapy, reduce antibiotic use, and mitigate UTI complications.
Collapse
Affiliation(s)
- Tej K Mattoo
- Pediatric Nephrologist, Wayne Pediatrics, Detroit, MI, USA.
- Department of Pediatrics, Wayne State University School of Medicine, Detroit, MI, USA.
- Department of Urology, Wayne State University School of Medicine, Detroit, MI, USA.
| | - John David Spencer
- The Kidney and Urinary Tract Center, Nationwide Children's Abigail Wexner Research Institute, Columbus, OH, USA
- The Ohio State University College of Medicine, Columbus, OH, USA
| |
Collapse
|
17
|
Mondal I, Mansour E, Zheng Y, Gupta R, Haick H. Self-Sustaining Triboelectric Nanosensors for Real-Time Urine Analysis in Smart Toilets. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2403385. [PMID: 39031720 DOI: 10.1002/smll.202403385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 06/03/2024] [Indexed: 07/22/2024]
Abstract
Healthcare has undergone a revolutionary shift with the advent of smart technologies, and smart toilets (STs) are among the innovative inventions offering non-invasive continuous health monitoring. The present technical challenges toward this development include limited sensitivity of integrated sensors, poor stability, slow response and the requirement external energy supply alongside manual sample collection. In this article, triboelectric nanosensor array (TENSA) is introduced featuring electrodes crafted from laser-induced 3D graphene with functional polymers like polystyrene, polyimide, and polycaprolactone for real-time urine analysis while generating 50 volts output via urine droplet-based triboelectrification. Though modulating interfacial double-layer capacitance, these sensors exhibit exceptional sensitivity and selectivity in detecting a broad spectrum of urinary biomarkers, including ions, glucose, and urea with a classification precision of 95% and concentration identification accuracy of up to 0.97 (R2), supported by artificial neural networks. Upon exposure to urine samples containing elevated levels of Na+, K+, and NH4 +, a notable decrease (ranging from 32% to 68%) is observed in output voltages. Conversely, urea induces an increase up to 13%. Experimental validation confirms the stability, robustness, reliability, and reproducibility of TENSA, representing a significant advancement in healthcare technology, offering the potential for improved disease management and prevention strategies.
Collapse
Affiliation(s)
- Indrajit Mondal
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa, 320002, Israel
| | - Elias Mansour
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa, 320002, Israel
| | - Youbin Zheng
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa, 320002, Israel
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, UK
| | - Ritu Gupta
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India
| | - Hossam Haick
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa, 320002, Israel
| |
Collapse
|
18
|
Milić L, Zambry NS, Ibrahim FB, Petrović B, Kojić S, Thiha A, Joseph K, Jamaluddin NF, Stojanović GM. Advances in textile-based microfluidics for biomolecule sensing. BIOMICROFLUIDICS 2024; 18:051502. [PMID: 39296324 PMCID: PMC11410389 DOI: 10.1063/5.0222244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Accepted: 08/23/2024] [Indexed: 09/21/2024]
Abstract
Textile-based microfluidic biosensors represent an innovative fusion of various multidisciplinary fields, including bioelectronics, material sciences, and microfluidics. Their potential in biomedicine is significant as they leverage textiles to achieve high demands of biocompatibility with the human body and conform to the irregular surfaces of the body. In the field of microfluidics, fabric coated with hydrophobic materials serves as channels through which liquids are transferred in precise amounts to the sensing element, which in this case is a biosensor. This paper presents a condensed overview of the current developments in textile-based microfluidics and biosensors in biomedical applications over the past 20 years (2005-2024). A literature search was performed using the Scopus database. The fabrication techniques and materials used are discussed in this paper, as these will be key in various modifications and advancements in textile-based microfluidics. Furthermore, we also address the gaps in the application of textile-based microfluidic analytical devices in biomedicine and discuss the potential solutions. Advances in textile-based microfluidics are enabled by various printing and fabric manufacturing techniques, such as screen printing, embroidery, and weaving. Integration of these devices into everyday clothing holds promise for future vital sign monitoring, such as glucose, albumin, lactate, and ion levels, as well as early detection of hereditary diseases through gene detection. Although most testing currently takes place in a laboratory or controlled environment, this field is rapidly evolving and pushing the boundaries of biomedicine, improving the quality of human life.
Collapse
Affiliation(s)
- Lazar Milić
- University of Novi Sad, Faculty of Technical Sciences, Trg D. Obradovica 6, 21000 Novi Sad, Serbia
| | | | | | - Bojan Petrović
- University of Novi Sad, Faculty of Technical Sciences, Trg D. Obradovica 6, 21000 Novi Sad, Serbia
| | - Sanja Kojić
- University of Novi Sad, Faculty of Technical Sciences, Trg D. Obradovica 6, 21000 Novi Sad, Serbia
| | | | | | - Nurul Fauzani Jamaluddin
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603 Kuala Lumpur, Malaysia
| | - Goran M Stojanović
- University of Novi Sad, Faculty of Technical Sciences, Trg D. Obradovica 6, 21000 Novi Sad, Serbia
| |
Collapse
|
19
|
Ashok K, Martinez T, Sesen J, Nasim S, Lang SS, Heuer G, Tucker A, Lopez-Ramirez MA, Smith ER, Ghalali A. Lectin-type oxidized LDL receptor-1 as a potential therapeutic target for cerebral cavernous malformations treatment. Front Neurosci 2024; 18:1442110. [PMID: 39234183 PMCID: PMC11371587 DOI: 10.3389/fnins.2024.1442110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Accepted: 08/05/2024] [Indexed: 09/06/2024] Open
Abstract
Introduction Cerebral cavernous malformations (CCMs) are pathologic lesions comprised of clusters of thin-walled capillaries characterized by abnormal proliferation, angiogenesis, and bleeding secondary to somatic or germline mutations in endothelial cells. CCMs can cause headaches, seizures and/or neurological defects. There is a clinical need to develop better tools to detect CCMs and follow their progression in conjunction with the current use of neuroimaging techniques. Here we present data supporting the utility of LOX-1 (lectin-type oxidized LDL receptor 1), a 50 kDa transmembrane protein implicated in endothelial cell dysfunction and ischemia, as a putative biomarker for CCM. Methods CCM urine samples (n = 23) were collected from pediatric CCM patients. Matched healthy controls (n = 24) were collected from pediatric patients with either Chiari I malformation or fatty filum terminale, and otherwise normal findings. All samples were collected with patient/family consent and institutional review board approval.Samples were analyzed with Olink Proteomic Proximity Extension Assay (PEA). Differences in expression for 2,925 unique proteins were quantified between healthy control urine samples and CCM urine samples. The results were normalized, validated, and analyzed for demographic bias. In addition to urine samples, CCM tissue from patients was harvested and used to create primary cell lines for in vitro analysis of LOX-1 expression, in addition to immunofluorescence of lesional tissue excised at surgery. Results ANOVA analysis of the CCM urine samples showed a statistically significant increase in LOX-1 compared to the control samples, with CCM patients exhibiting a > 5-fold increase in urinary expression. Corroborating these elevated levels of circulating marker, analysis of source tissue from surgically resected CCMs revealed that LOX-1 is increased in both CCM patient cavernoma primary cell lines and operative specimens. Conclusion LOX-1 is involved with pathways implicated in CCM pathogenesis and our data here reveals that LOX-1 expression is significantly elevated in CCM patients as compared to matched healthy control individuals, including both source tissue from surgically excised CCMs and in analysis of samples collected from outside of the central nervous system, particularly urine. This proof-of-principle data suggests that LOX-1 may have potential utility as a target for CCM treatment and supports further investigation related to its potential mechanistic impact on CCM pathogenesis.
Collapse
Affiliation(s)
- Karthik Ashok
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
- Department of Surgery, Harvard Medical School, Boston, MA, United States
| | - Tyra Martinez
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
- Department of Surgery, Harvard Medical School, Boston, MA, United States
| | - Julie Sesen
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
- Department of Surgery, Harvard Medical School, Boston, MA, United States
| | - Sana Nasim
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
| | - Shih-Shan Lang
- Division of Neurosurgery, Children's Hospital of Philadelphia, Philadelphia, PA, United States
- Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
| | - Gregory Heuer
- Division of Neurosurgery, Children's Hospital of Philadelphia, Philadelphia, PA, United States
- Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
| | - Alexander Tucker
- Division of Neurosurgery, Children's Hospital of Philadelphia, Philadelphia, PA, United States
- Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
| | | | - Edward R Smith
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
- Department of Surgery, Harvard Medical School, Boston, MA, United States
- Department of Neurosurgery, Boston Children's Hospital, Boston, MA, United States
| | - Aram Ghalali
- Vascular Biology Program, Boston Children's Hospital, Boston, MA, United States
- Department of Surgery, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
20
|
da Silva CR, Carvalho HC, Lazo Osório RA, Fernandes AB, Silveira L. Differences in whole blood before and after hemodialysis session of subjects with chronic kidney disease measured by Raman spectroscopy. Lasers Med Sci 2024; 39:175. [PMID: 38970671 DOI: 10.1007/s10103-024-04125-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 06/24/2024] [Indexed: 07/08/2024]
Abstract
This study aimed to identify differences in the composition of whole blood of patients with chronic kidney disease (CKD), before and after a hemodialysis session (HDS), and possible differences in blood composition between stages and between genders using Raman spectroscopy and principal component analysis (PCA). Whole blood samples were collected from 40 patients (20 women and 20 men), before and after a HDS. Raman spectra were obtained and the spectra were evaluated by PCA and partial least squares (PLS) regression. Mean spectra and difference spectrum between the groups were calculated: stages Before and After HDS, and gender Women and Men, which had their most intense peaks identified. Stage: mean spectra and difference spectrum indicated positive peaks that could be assigned to red blood cells, hemoglobin and deoxi-hemoglobin in the group Before HDS. There was no statistically significant difference by PCA. Gender: mean spectra and difference spectrum Before HDS indicated positive peaks that could be assigned to red blood cells, hemoglobin and deoxi-hemoglobin with greater intensity in the group Women, and negative peaks to white blood cells and serum, with greater intensity in the group Men. There was statistically significant difference by PCA, which also identified the peaks assigned to white blood cells, serum and porphyrin for Women and red blood cells and amino acids (tryptophan) for Men. PLS model was able to classify the spectra of the gender with 83.7% accuracy considering the classification per patient. The Raman technique highlighted gender differences in pacients with CKD.
Collapse
Affiliation(s)
| | - Henrique Cunha Carvalho
- Centro de Inovação, Tecnologia e Educação - CITÉ, Parque de Inovação Tecnológica de São José dos Campos, Estrada Dr. Altino Bondensan, 500, Eugênio de Melo, São José dos Campos, 12247-016, SP, Brazil
- Universidade Tecnológica Federal do Paraná - UTFPR, Via Marginal Rosalina Maria dos Santos, 1233, Bloco B, Vila Urbanizada, Campo Mourão, 87301-899, PR, Brazil
| | - Rodrigo Alexis Lazo Osório
- Centro de Inovação, Tecnologia e Educação - CITÉ, Parque de Inovação Tecnológica de São José dos Campos, Estrada Dr. Altino Bondensan, 500, Eugênio de Melo, São José dos Campos, 12247-016, SP, Brazil
| | - Adriana Barrinha Fernandes
- Universidade Anhembi Morumbi - UAM, Rua Casa do Ator, 294, Vila Olímpia, São Paulo, 04546-001, SP, Brazil
- Centro de Inovação, Tecnologia e Educação - CITÉ, Parque de Inovação Tecnológica de São José dos Campos, Estrada Dr. Altino Bondensan, 500, Eugênio de Melo, São José dos Campos, 12247-016, SP, Brazil
| | - Landulfo Silveira
- Universidade Anhembi Morumbi - UAM, Rua Casa do Ator, 294, Vila Olímpia, São Paulo, 04546-001, SP, Brazil.
- Centro de Inovação, Tecnologia e Educação - CITÉ, Parque de Inovação Tecnológica de São José dos Campos, Estrada Dr. Altino Bondensan, 500, Eugênio de Melo, São José dos Campos, 12247-016, SP, Brazil.
| |
Collapse
|
21
|
Pohanka M, Zakova J. Urine Test Strip Quantitative Assay with a Smartphone Camera. Int J Anal Chem 2024; 2024:6004970. [PMID: 38529171 PMCID: PMC10963100 DOI: 10.1155/2024/6004970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/26/2024] [Accepted: 03/12/2024] [Indexed: 03/27/2024] Open
Abstract
Urine test strips for urinalysis are a common diagnostic tool with minimal costs and are used in various situations including homecare and hospitalization. The coloration scaled by the naked eye is simple, but it is suitable for semiquantitative analysis only. In this paper, a colorimetric assay is developed based on a smartphone digital camera and urine test strips. Assays of pH, albumin, glucose, and lipase activity were performed as a tool for the diagnosis of aciduria, alkaluria, glycosuria, proteinuria, and leukocyturia. The RGB color channels were analyzed in the colorimetric assay, and the assay exerted good sensitivity, and all the particular diagnoses proved to be reliable. The limits of detection for glucose (0.11 mmol/L), albumin (0.15 g/L), and lipase (2.50 U/μL) were low enough to cover the expected physiological concentration, and the range for pH was also satisfactory. The urine test strips with a camera as an output detector proved applicability to spiked urine samples, and the results were also well in comparison to the standard assays which confirms the practical relevance of the presented findings.
Collapse
Affiliation(s)
- Miroslav Pohanka
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| | - Jitka Zakova
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| |
Collapse
|
22
|
Sequeira-Antunes B, Ferreira HA. Nucleic Acid Aptamer-Based Biosensors: A Review. Biomedicines 2023; 11:3201. [PMID: 38137422 PMCID: PMC10741014 DOI: 10.3390/biomedicines11123201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 11/23/2023] [Accepted: 11/29/2023] [Indexed: 12/24/2023] Open
Abstract
Aptamers, short strands of either DNA, RNA, or peptides, known for their exceptional specificity and high binding affinity to target molecules, are providing significant advancements in the field of health. When seamlessly integrated into biosensor platforms, aptamers give rise to aptasensors, unlocking a new dimension in point-of-care diagnostics with rapid response times and remarkable versatility. As such, this review aims to present an overview of the distinct advantages conferred by aptamers over traditional antibodies as the molecular recognition element in biosensors. Additionally, it delves into the realm of specific aptamers made for the detection of biomarkers associated with infectious diseases, cancer, cardiovascular diseases, and metabolomic and neurological disorders. The review further elucidates the varying binding assays and transducer techniques that support the development of aptasensors. Ultimately, this review discusses the current state of point-of-care diagnostics facilitated by aptasensors and underscores the immense potential of these technologies in advancing the landscape of healthcare delivery.
Collapse
Affiliation(s)
- Beatriz Sequeira-Antunes
- Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Campo Grande, 1749-016 Lisboa, Portugal
- Exotictarget, 4900-378 Viana do Castelo, Portugal
- Instituto de Engenharia de Sistemas e Computadores-Microsistemas e Nanotecnologias (INESC-MN), 1000-029 Lisbon, Portugal
| | - Hugo Alexandre Ferreira
- Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Campo Grande, 1749-016 Lisboa, Portugal
- Exotictarget, 4900-378 Viana do Castelo, Portugal
| |
Collapse
|
23
|
Hopsort G, Latapie L, Groenen Serrano K, Loubière K, Tzedakis T. Deciphering the human urine matrix: a new approach to simultaneously quantify the main ions and organic compounds by ion chromatography/mass spectrometry (IC-MS). Anal Bioanal Chem 2023; 415:5337-5352. [PMID: 37394521 DOI: 10.1007/s00216-023-04808-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/10/2023] [Accepted: 06/13/2023] [Indexed: 07/04/2023]
Abstract
Analyzing the composition of (human) urine plays a major role in the fields of biology and medicine. Organic molecules (such as urea, creatine) and ions (such as chloride, sulfate) are the major compounds present in urine, the quantification of which allows for the diagnosis of a subject's health condition. Various analytical methods have been reported for studying urine components and validated on the basis of known and referenced compounds. The present work introduces a new method able to simultaneously determine both major organic molecules and ions contained in urine, by combining ion chromatography using a conductimetric detector with mass spectroscopy. The analysis of organic and ionized compounds (anionic and cationic) was achieved in double injections. For quantification, the standard addition method was used. Human urine samples were pre-treated (diluted and filtered) for IC-CD/MS analysis. The analytes were separated in 35 min. Calibration ranges (0-20 mg.L-1) and correlation coefficients (> 99.3%) as well as detection (LODs < 0.75 mg.L-1) and quantification (LOQs < 2.59 mg.L-1) limits were obtained for the main organic molecules (lactic, hippuric, citric, uric, oxalic acids, urea, creatine, and creatinine) and ions (chloride, sulfate, phosphate, sodium, ammonium, potassium, calcium, and magnesium) contained in urine. The intra- and inter-day accuracies of the analytes consistently ranged from 0.1 to 5.0%, and the precision was within 4.0%. For all analytes, no significant matrix effects were observed, and recoveries ranged from 94.9 to 102.6%. Finally, quantitative results of analytes were obtained from 10 different human urine samples.
Collapse
Affiliation(s)
- Guillaume Hopsort
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France.
| | - Laure Latapie
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| | - Karine Groenen Serrano
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| | - Karine Loubière
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| | - Theodore Tzedakis
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France.
| |
Collapse
|
24
|
Hermsen S, Verbiest V, Buijs M, Wentink E. Perceived Use Cases, Barriers, and Requirements for a Smart Health-Tracking Toilet Seat: Qualitative Focus Group Study. JMIR Hum Factors 2023; 10:e44850. [PMID: 37566450 PMCID: PMC10457698 DOI: 10.2196/44850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 04/13/2023] [Accepted: 06/21/2023] [Indexed: 08/12/2023] Open
Abstract
BACKGROUND Smart bathroom technology offers unrivaled opportunities for the automated measurement of a range of biomarkers and other data. Unfortunately, efforts in this area are mostly driven by a technology push rather than market pull approach, which decreases the chances of successful adoption. As yet, little is known about the use cases, barriers, and desires that potential users of smart bathrooms perceive. OBJECTIVE This study aimed to investigate how participants from the general population experience using a smart sensor-equipped toilet seat installed in their home. The study contributes to answering the following questions: What use cases do citizens see for this innovation? and What are the limitations and barriers to its everyday use that they see, including concerns regarding privacy, the lack of fit with everyday practices, and unmet expectations for user experience? METHODS Overall, 31 participants from 30 households participated in a study consisting of 3 (partially overlapping) stages: sensitizing, in which participants filled out questionnaires to trigger their thoughts about smart bathroom use and personal health; provotyping, in which participants received a gentle provocation in the form of a smart toilet seat, which they used for 2 weeks; and discussion, in which participants took part in a web-based focus group session to discuss their experiences. RESULTS Participants mostly found the everyday use of the toilet, including installation and dismantling when necessary, to be relatively easy and free of complications. Where complications occurred, participants mentioned issues related to the design of the prototype, technology, or mismatches with normal practices in using toilets and hygiene. A broad range of use cases were mentioned, ranging from signaling potentially detrimental health conditions or exacerbations of existing conditions to documenting physical data to measuring biomarkers to inform a diagnosis and behavioral change. Participants differed greatly in whether they let others use, or even know about, the seat. Ownership and control over their own data were essential for most participants. CONCLUSIONS This study showed that participants felt that a smart toilet seat could be acceptable and effective, as long as it fits everyday practices concerning toilet use and hygiene. The range of potential uses for a smart toilet seat is broad, as long as privacy and control over disclosure and data are warranted.
Collapse
Affiliation(s)
| | | | | | - Eva Wentink
- OnePlanet Research Center, Wageningen, Netherlands
| |
Collapse
|