1
|
Tracking SARS-CoV-2 Omicron lineages using real-time reverse transcriptase PCR assays and prospective comparison with genome sequencing. Sci Rep 2023; 13:17478. [PMID: 37838804 PMCID: PMC10576821 DOI: 10.1038/s41598-023-44796-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 10/12/2023] [Indexed: 10/16/2023] Open
Abstract
Omicron has become the dominant SARS-CoV-2 variant globally since December 2021, with distinct waves being associated with separate Omicron sublineages. Rapid detection of BA.1, BA.2, BA.4, and BA.5 was accomplished in the province of Alberta, Canada, through the design and implementation of real-time reverse transcriptase PCR assays targeting S:N501Y, S:ins214EPE, S:H69/V70, ORF7b:L11F, and M:D3N. Using the combination of results for each of these markers, samples could be designated as belonging to sublineages within BA.1, BA.2, BA.4, or BA.5. The analytical sensitivity of these markers ranged from 132 to 2229 copies/mL and in-laboratory accuracy was 98.9-100%. A 97.3% agreement using 12,592 specimens was demonstrated for the assays compared to genome sequencing. The use of these assays, combined with genome sequencing, facilitated the surveillance of SARS-CoV-2 lineages throughout a BA.5-dominated period.
Collapse
|
2
|
Long follow-up of BNT162b2 mRNA vaccine in healthcare workers (2020-2022): A retrospective longitudinal SARS-CoV-2 serological surveillance. Hum Vaccin Immunother 2023; 19:2258632. [PMID: 37724517 PMCID: PMC10512804 DOI: 10.1080/21645515.2023.2258632] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 09/11/2023] [Indexed: 09/21/2023] Open
Abstract
SARS-CoV-2 anti-spike IgG production and protection from severe respiratory illness should be explored in greater depth after COVID-19 booster vaccination. This longitudinal observational retrospective study investigated the anti-spike IgG response elicited by the first, second and booster doses of BNT162b2 mRNA vaccine in healthcare workers (HCW) at San Martino IRCCS Policlinico Hospital (Genoa) up to the 12th month. Sequential blood sampling was performed at T0 (prior to vaccination), T1 (21 days after the 1st dose of vaccine), T2, T3, T4, T5, T6 (7 days and 1, 3, 6 and 9 months after the 2nd dose, respectively), T7 and T8 (1 and 3 months after a booster dose). A SARS-CoV-2 IgG panel (Bio-Rad, Marnes-la-Coquette, France) was used to determine levels of receptor-binding domain (RBD), spike-1 (S1), spike-2 and nucleocapsid structural proteins of SARS-CoV-2. In the 51 HCWs evaluated, seroprevalence was 96% (49/51) at T1 and 100% (51/51) from T2 to T5 for RBD and S1. At T6, only one HCW was negative. T2 [RBD = 2945 (IQR:1693-5364); S1 = 1574 (IQR:833-3256) U/mL], and T7 [RBD = 8204 (IQR:4129-11,912); S1 = 4124 (IQR:2124-6326) U/mL] were characterized by the highest antibody values. Significant humoral increases in RBD and S1 were documented at T7 and T8 compared to T2 and T4, respectively (p-value < .001). Following vaccination with BNT162b2 and a booster dose in the 9th month, naïve and healthy subjects show high antibody titers up to 12 months and a protective humoral response against COVID-19 disease lasting up to 20 months after the last booster.
Collapse
|
3
|
Rapid identification of SARS-CoV-2 variants: Validation of the Simplexa SARS-CoV-2 Variant Direct assay. J Virol Methods 2023:114759. [PMID: 37257757 PMCID: PMC10226276 DOI: 10.1016/j.jviromet.2023.114759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/22/2023] [Accepted: 05/27/2023] [Indexed: 06/02/2023]
Abstract
The circulation of certain SARS-CoV-2 variants may have a great impact on the epidemiological status of a geographical area; therefore, it is important that their presence is monitored. Currently, the gold standard method used to identify newly emerged variants is sequencing of either genes or whole genomes. However, since this method is relatively expensive and has a long turnaround time, other rapid strategies should also be employed. The current study aimed to evaluate the performance of the Simplexa® SARS-CoV-2 Variants Direct assay, which is a RT-PCR that determines the variant present in a nasopharyngeal swab sample in approximately two hours. Totally, 527 positive samples for SARS-CoV-2 were analyzed from January until December 2022 and next-generation sequencing (NGS) was used as the reference method. The assay showed high sensitivity, ranging from 94.12% to 100%, depending on the variant. The assay also showed high specificity, reaching 100% for Delta and BA.1 variants, and 99.74% and 98.67% for BA.2 and BA.4/BA.5 variants, respectively. Moreover, the assay was able to identify the correct variant category in the presence of any subvariant in the sample. We conclude that the assay can be used to facilitate faster monitoring of circulating SARS-CoV-2 variants, however sequencing cannot be completely replaced, since new variants always emerge, and constant updates are needed, so that the user is able to interpret the melting curve patterns.
Collapse
|
4
|
Simultaneous detection of omicron and other SARS-CoV-2 variants by multiplex PCR MassARRAY technology. Sci Rep 2023; 13:2089. [PMID: 36747014 PMCID: PMC9900542 DOI: 10.1038/s41598-023-28715-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 01/23/2023] [Indexed: 02/08/2023] Open
Abstract
The rapid emergence of SARS-CoV-2 variants with high severity and transmutability adds further urgency for rapid and multiplex molecular testing to identify the variants. A nucleotide matrix-assisted laser-desorption-ionization time-of-flight mass spectrophotometry (MALDI-TOF MS)-based assay was developed (called point mutation array, PMA) to identify four major SARS-CoV-2 variants of concern (VOCs) including Alpha, Beta, Delta, and Omicron (namely PMA-ABDO) and differentiate Omicron subvariant (namely PMA-Omicron). PMA-ABDO and PMA-Omicron consist of 24 and 28 mutation sites of the spike gene. Both PMA panels specifically identified VOCs with as low as 10 viral copies/µl. The panel has shown a 100% concordant with the Next Generation Sequencing (NGS) results testing on 256 clinical specimens with real-time PCR cycle threshold (Ct) values less than 26. It showed a higher sensitivity over NGS; 25/28 samples were positive by PMA but not NGS in the clinical samples with PCR Ct higher than 26. Due to the mass of nucleotide used to differentiate between wild-type and mutation strains, the co-infection or recombination of multiple variants can be determined by the PMA method. This method is flexible in adding a new primer set to identify a new emerging mutation site among the current circulating VOCs and the turnaround time is less than 8 h. However, the spike gene sequencing or NGS retains the advantage of detecting newly emerged variants.
Collapse
|
5
|
From Field Tests to Molecular Tools-Evaluating Diagnostic Tests to Improve Rabies Surveillance in Namibia. Viruses 2023; 15:v15020371. [PMID: 36851585 PMCID: PMC9966532 DOI: 10.3390/v15020371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 01/23/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023] Open
Abstract
Rabies is endemic in Namibia and is present both in wildlife carnivores and domestic free-roaming dogs. The disease thus represents a challenge for public human and veterinary disease control. Namibia has implemented a national strategic plan to control rabies and the country's activities are supported by international organizations. To this end, rabies diagnosis at the Central Veterinary Laboratory (CVL) was improved in the frame of a World Organization for Animal Health (WOAH) laboratory twinning program: from practical sampling techniques and the use of lateral flow devices to a novel universal and discriminatory quantitative real-time Reverse transcription polymerase chain reaction (RT-qPCR), which easily identify dog-associated rabies viruses. The procedures applied and the results can be used as a template to improve rabies laboratory diagnosis.
Collapse
|
6
|
Simultaneous Detection of Omicron and Other SARS-CoV-2 Variants by Multiplex PCR MassARRAY Technology. RESEARCH SQUARE 2023:rs.3.rs-2482226. [PMID: 36711810 PMCID: PMC9882655 DOI: 10.21203/rs.3.rs-2482226/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The rapid emergence of SARS-CoV-2 variants with high severity and transmutability adds further urgency for rapid and multiplex molecular testing to identify the variants. A nucleotide matrix-assisted laser-desorption-ionization time-of-flight mass spectrophotometry (MALDI-TOF MS)-based assay was developed (called point mutation array, PMA) to identify four major SARS-CoV-2 variants of concern (VOCs) including Alpha, Beta, Delta, and Omicron (namely PMA-ABDO) and differentiate Omicron subvariant (namely PMA-Omicron). PMA-ABDO and PMA-Omicron consist of 24 and 28 mutation sites of the spike gene. Both PMA panels specifically identified VOCs with as low as 10 viral copies/ µl. The panel has shown a 100% concordant with the Next Generation Sequencing (NGS) results testing on 256 clinical specimens with real-time PCR cycle threshold (Ct) values less than 26. It showed a higher sensitivity over NGS; 25/28 samples were positive by PMA but not NGS in the clinical samples with PCR Ct higher than 26. Due to the mass of nucleotide used to differentiate between wild-type and mutation strains, the co-infection or recombination of multiple variants can be determined by the PMA method. This method is flexible in adding a new primer set to identify a new emerging mutation site among the current circulating VOCs and the turnaround time is less than 8 hours. However, the spike gene sequencing or NGS retains the advantage of detecting newly emerged variants.
Collapse
|
7
|
Two-Period Study Results from a Large Italian Hospital Laboratory Attesting SARS-CoV-2 Variant PCR Assay Evolution. Microbiol Spectr 2022; 10:e0292222. [PMID: 36409091 PMCID: PMC9769628 DOI: 10.1128/spectrum.02922-22] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/24/2022] [Indexed: 11/23/2022] Open
Abstract
In keeping with the evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the COVID-19 causative agent, PCR assays have been developed to rapidly detect SARS-CoV-2 variants, which have emerged since the first (Alpha) variant was identified. Based on specific assortment of SARS-CoV-2 spike-protein mutations (ΔH69/V70, E484K, N501Y, W152C, L452R, K417N, and K417T) among the major variants known to date, Seegene Allplex SARS-CoV-2 Variants I and Variants II assays have been available since a few months before the last (Omicron) variant became predominant. Using S gene next-generation sequencing (NGS) as the SARS-CoV-2 variant identification reference method, we assessed the results of SARS-CoV-2-positive nasopharyngeal swab samples from two testing periods, before (n = 288, using only Variants I) and after (n = 77, using both Variants I and Variants II) the appearance of Omicron. The Variants I assay allowed correct identification for Alpha (37/37), Beta/Gamma (28/30), or Delta (220/221) variant-positive samples. The combination of the Variants I and Variants II assays allowed correct identification for 61/77 Omicron variant-positive samples. While 16 samples had the K417N mutation undetected with the Variants II assay, 74/77 samples had both ΔH69/V70 and N501Y mutations detected with the Variants I assay. If considering only the results by the Variants I assay, 6 (2 Beta variant positive, 1 Delta variant positive, and 3 Omicron variant positive) of 365 samples tested in total provided incorrect identification. We showed that the Variants I assay alone might be more suitable than both the Variants I and Variants II assays to identify currently circulating SARS-CoV-2 variants. Inclusion of additional variant-specific mutations should be expected in the development of future assays. IMPORTANCE Omicron variants of SARS-CoV-2 pose more important public health concerns than the previously circulating Alpha or Delta variants, particularly regarding the efficacy of anti-SARS-CoV-2 vaccines and therapeutics. Precise identification of these variants highly requires performant PCR-based assays that allow us to reduce the reliance on NGS-based assays, which remain the reference method in this topic. While the current epidemiological SARS-CoV-2 pandemic context suggests that PCR assays such as the Seegene Variants II may be dispensable, we took advantage of NGS data obtained in this study to show that the array of SARS-CoV-2 spike protein mutations in the Seegene Variants II assay may be suboptimal. This reinforces the concept that initially developed PCR assays for SARS-CoV-2 variant detection could be no longer helpful if the SARS-CoV-2 pandemic evolves to newly emerging variants.
Collapse
|
8
|
Development, testing and validation of a SARS-CoV-2 multiplex panel for detection of the five major variants of concern on a portable PCR platform. Front Public Health 2022; 10:1042647. [PMID: 36590003 PMCID: PMC9798920 DOI: 10.3389/fpubh.2022.1042647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 11/11/2022] [Indexed: 12/16/2022] Open
Abstract
Many SARS-CoV-2 variants have emerged during the course of the COVID-19 pandemic. These variants have acquired mutations conferring phenotypes such as increased transmissibility or virulence, or causing diagnostic, therapeutic, or immune escape. Detection of Alpha and the majority of Omicron sublineages by PCR relied on the so-called S gene target failure due to the deletion of six nucleotides coding for amino acids 69-70 in the spike (S) protein. Detection of hallmark mutations in other variants present in samples relied on whole genome sequencing. However, whole genome sequencing as a diagnostic tool is still in its infancy due to geographic inequities in sequencing capabilities, higher cost compared to other molecular assays, longer turnaround time from sample to result, and technical challenges associated with producing complete genome sequences from samples that have low viral load and/or high background. Hence, there is a need for rapid genotyping assays. In order to rapidly generate information on the presence of a variant in a given sample, we have created a panel of four triplex RT-qPCR assays targeting 12 mutations to detect and differentiate all five variants of concern: Alpha, Beta, Gamma, Delta, and Omicron. We also developed an expanded pentaplex assay that can reliably distinguish among the major sublineages (BA.1-BA.5) of Omicron. In silico, analytical and clinical testing of the variant panel indicate that the assays exhibit high sensitivity and specificity. This panel can help fulfill the need for rapid identification of variants in samples, leading to quick decision making with respect to public health measures, as well as treatment options for individuals. Compared to sequencing, these genotyping PCR assays allow much faster turn-around time from sample to results-just a couple hours instead of days or weeks.
Collapse
|
9
|
Variant-specific RT-qPCR for rapid screening of B.1.617 mutations in SARS-CoV-2. Libyan J Med 2022; 17:2121252. [PMID: 36062935 PMCID: PMC9467536 DOI: 10.1080/19932820.2022.2121252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The continuous emergence of new SARS-CoV-2 variants required rapid and reliable diagnostic methods for early detection and monitoring of the spread of the virus, especially in low-resource countries where whole genome sequencing is not available. We aimed to evaluate and compare the performance of two different RT-qPCR screening assays for the detection of B.1.617 lineage mutations. A total of 85 SARS-CoV-2 positive samples were collected between 9th August and 10 September 2021 and screened by two mutation-specific RT-qPCR assays for simultaneous detection of B.1.617.1 and B.1.617.2 lineage mutations. VIASURE Variant II PCR assay identified 2 Delta variant-specific mutations (L452R, and P681 R) in 80% of tested samples, while the PKamp™ Variant Detect™ assay was only able to detect one Delta variant specific mutation (L452R) in 75% of tested samples. This is the first report to show the Delta variant as the cause of the third wave in Libya. The use of multiplex RT-qPCR assays has allowed the identification of new variants for rapid screening. However, RT-qPCR results should be confirmed by whole genome sequencing of SARS-COV-2.
Collapse
|
10
|
Evaluation and comparison of the sensitivity of three commercial RT-qPCR kits used for the detection of SARS-CoV-2 in Santiago, Chile. Front Public Health 2022; 10:1010336. [PMID: 36518569 PMCID: PMC9742446 DOI: 10.3389/fpubh.2022.1010336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 11/08/2022] [Indexed: 11/29/2022] Open
Abstract
Introduction The COVID-19 pandemic is still in force, causing global public health challenges and threats. Although vaccination and herd immunity have proven to be the most efficient way to control the pandemic, massive and early testing of patients using the RT-qPCR technique is crucial for constant genomic surveillance. The appearance of variants of SARS-CoV-2 with new mutations can reduce the efficiency of diagnostic detection. In this sense, several commercial RT-qPCR kits have been the target of extensive analysis because low assay performance could lead to false-negative diagnoses. Methods In this study, we evaluated the performance of three commercial RT-qPCR kits; Thermo Fisher (TaqMan 2019-nCoV Assay Kit v1), BGI and Roche (LightCycler® Multiplex RNA Virus Master) used for the diagnosis of COVID-19 throughout the pandemic in Santiago de Chile. Results Under our best assay conditions, we found significant differences in Cq amplification values for control and viral probes, against the same nasopharyngeal swab samples (NPSs). In addition, in some cases, the sensitivity of the RT-qPCR kits decreased against viral variants. Conclusion Our study suggests evaluating the RT-qPCR kits used to detect SARS-CoV-2 because variants such as Omicron, which has several mutations, can compromise their detection and underestimate viral circulation.
Collapse
|
11
|
A Robust, Highly Multiplexed Mass Spectrometry Assay to Identify SARS-CoV-2 Variants. Microbiol Spectr 2022; 10:e0173622. [PMID: 36069609 PMCID: PMC9604185 DOI: 10.1128/spectrum.01736-22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 08/12/2022] [Indexed: 12/31/2022] Open
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants are characterized by differences in transmissibility and response to therapeutics. Therefore, discriminating among them is vital for surveillance, infection prevention, and patient care. While whole-genome sequencing (WGS) is the "gold standard" for variant identification, molecular variant panels have become increasingly available. Most, however, are based on limited targets and have not undergone comprehensive evaluation. We assessed the diagnostic performance of the highly multiplexed Agena MassARRAY SARS-CoV-2 Variant Panel v3 to identify variants in a diverse set of 391 SARS-CoV-2 clinical RNA specimens collected across our health systems in New York City, USA and Bogotá, Colombia (September 2, 2020 to March 2, 2022). We demonstrated almost perfect levels of interrater agreement between this assay and WGS for 9 of 11 variant calls (κ ≥ 0.856) and 25 of 30 targets (κ ≥ 0.820) tested on the panel. The assay had a high diagnostic sensitivity (≥93.67%) for contemporary variants (e.g., Iota, Alpha, Delta, and Omicron [BA.1 sublineage]) and a high diagnostic specificity for all 11 variants (≥96.15%) and all 30 targets (≥94.34%) tested. Moreover, we highlighted distinct target patterns that could be utilized to identify variants not yet defined on the panel, including the Omicron BA.2 and other sublineages. These findings exemplified the power of highly multiplexed diagnostic panels to accurately call variants and the potential for target result signatures to elucidate new ones. IMPORTANCE The continued circulation of SARS-CoV-2 amid limited surveillance efforts and inconsistent vaccination of populations has resulted in the emergence of variants that uniquely impact public health systems. Thus, in conjunction with functional and clinical studies, continuous detection and identification are quintessential to informing diagnostic and public health measures. Furthermore, until WGS becomes more accessible in the clinical microbiology laboratory, the ideal assay for identifying variants must be robust, provide high resolution, and be adaptable to the evolving nature of viruses like SARS-CoV-2. Here, we highlighted the diagnostic capabilities of a highly multiplexed commercial assay to identify diverse SARS-CoV-2 lineages that circulated from September 2, 2020 to March 2, 2022 among patients seeking care in our health systems. This assay demonstrated variant-specific signatures of nucleotide/amino acid polymorphisms and underscored its utility for the detection of contemporary and emerging SARS-CoV-2 variants of concern.
Collapse
|
12
|
SARS-CoV-2 wastewater monitoring using a novel PCR-based method rapidly captured the Delta-to-Omicron ΒΑ.1 transition patterns in the absence of conventional surveillance evidence. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022. [PMID: 35753493 DOI: 10.1101/2022.01.28.21268186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Conventional SARS-CoV-2 surveillance based on genotyping of clinical samples is characterized by challenges related to the available sequencing capacity, population sampling methodologies, and is time, labor, and resource-demanding. Wastewater-based variant surveillance constitutes a valuable supplementary practice, since it does not require extensive sampling, and provides information on virus prevalence in a timely and cost-effective manner. Consequently, we developed a sensitive real-time RT-PCR-based approach that exclusively amplifies and quantifies SARS-CoV-2 genomic regions carrying the S:Δ69/70 deletion, indicative of the Omicron BA.1 variant, in wastewater. The method was incorporated in the analysis of composite daily samples taken from the main Wastewater Treatment Plant of Thessaloniki, Greece, from 1 December 2021. The applicability of the methodology is dependent on the epidemiological situation. During Omicron BA.1 global emergence, Thessaloniki was experiencing a massive epidemic wave attributed solely to the Delta variant, according to genomic surveillance data. Since Delta does not possess the S:Δ69/70, the emergence of Omicron BA.1 could be monitored via the described methodology. Omicron BA.1 was detected in sewage samples on 19 December 2021 and a rapid increase of its viral load was observed in the following 10-day period, with an estimated early doubling time of 1.86 days. The proportion of the total SARS-CoV-2 load attributed to BA.1 reached 91.09 % on 7 January, revealing a fast Delta-to-Omicron transition pattern. The detection of Omicron BA.1 subclade in wastewater preceded the outburst of reported (presumable) Omicron cases in the city by approximately 7 days. The proposed wastewater surveillance approach based on selective PCR amplification of a genomic region carrying a deletion signature enabled rapid, real-time data acquisition on Omicron BA.1 prevalence and dynamics during the slow remission of the Delta wave. Timely provision of these results to State authorities readily influences the decision-making process for targeted public health interventions, including control measures, awareness, and preparedness.
Collapse
|
13
|
SARS-CoV-2 wastewater monitoring using a novel PCR-based method rapidly captured the Delta-to-Omicron ΒΑ.1 transition patterns in the absence of conventional surveillance evidence. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:156932. [PMID: 35753493 PMCID: PMC9225927 DOI: 10.1016/j.scitotenv.2022.156932] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 05/09/2022] [Accepted: 06/20/2022] [Indexed: 05/21/2023]
Abstract
Conventional SARS-CoV-2 surveillance based on genotyping of clinical samples is characterized by challenges related to the available sequencing capacity, population sampling methodologies, and is time, labor, and resource-demanding. Wastewater-based variant surveillance constitutes a valuable supplementary practice, since it does not require extensive sampling, and provides information on virus prevalence in a timely and cost-effective manner. Consequently, we developed a sensitive real-time RT-PCR-based approach that exclusively amplifies and quantifies SARS-CoV-2 genomic regions carrying the S:Δ69/70 deletion, indicative of the Omicron BA.1 variant, in wastewater. The method was incorporated in the analysis of composite daily samples taken from the main Wastewater Treatment Plant of Thessaloniki, Greece, from 1 December 2021. The applicability of the methodology is dependent on the epidemiological situation. During Omicron BA.1 global emergence, Thessaloniki was experiencing a massive epidemic wave attributed solely to the Delta variant, according to genomic surveillance data. Since Delta does not possess the S:Δ69/70, the emergence of Omicron BA.1 could be monitored via the described methodology. Omicron BA.1 was detected in sewage samples on 19 December 2021 and a rapid increase of its viral load was observed in the following 10-day period, with an estimated early doubling time of 1.86 days. The proportion of the total SARS-CoV-2 load attributed to BA.1 reached 91.09 % on 7 January, revealing a fast Delta-to-Omicron transition pattern. The detection of Omicron BA.1 subclade in wastewater preceded the outburst of reported (presumable) Omicron cases in the city by approximately 7 days. The proposed wastewater surveillance approach based on selective PCR amplification of a genomic region carrying a deletion signature enabled rapid, real-time data acquisition on Omicron BA.1 prevalence and dynamics during the slow remission of the Delta wave. Timely provision of these results to State authorities readily influences the decision-making process for targeted public health interventions, including control measures, awareness, and preparedness.
Collapse
|
14
|
SARS-CoV-2 Variants Identification: Overview of Molecular Existing Methods. Pathogens 2022; 11:pathogens11091058. [PMID: 36145490 PMCID: PMC9504725 DOI: 10.3390/pathogens11091058] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/30/2022] [Accepted: 09/13/2022] [Indexed: 11/16/2022] Open
Abstract
Since the beginning of COVID-19 pandemic the Real Time sharing of genome sequences of circulating virus supported the diagnostics and surveillance of SARS-CoV-2 and its transmission dynamics. SARS-CoV-2 straightaway showed its tendency to mutate and adapt to the host, culminating in the emergence of variants; so it immediately became of crucial importance to be able to detect them quickly but also to be able to monitor in depth the changes on the whole genome to early identify the new possibly emerging variants. In this scenario, this manuscript aims to provide an overview of the existing methods for the identification of SARS-CoV-2 variants (from rapid method based on identification of one or more specific mutations to Whole Genome sequencing approach-WGS), taking into account limitations, advantages and applications of them in the field of diagnosis and surveillance of SARS-CoV-2.
Collapse
|
15
|
Rapid and qualitative identification of SARS-CoV-2 mutations associated with variants of concern using a multiplex RT-PCR assay coupled with melting analysis. Int J Infect Dis 2022; 122:401-404. [PMID: 35760381 PMCID: PMC9233866 DOI: 10.1016/j.ijid.2022.06.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 05/20/2022] [Accepted: 06/21/2022] [Indexed: 01/25/2023] Open
Abstract
OBJECTIVES Considering the spread of new genetic variants and their impact on public health, it is important to have assays that are able to rapidly detect SARS-CoV-2 variants. METHODS We retrospectively examined 118 positive nasopharyngeal swabs, first characterized by the Sanger sequencing, using the Simplexa® SARS-CoV-2 Variants Direct assay, with the aim of evaluating the performance of the assay to detect N501Y, G496S, Q498R, Y505H, E484K, E484Q, E484A, and L452R mutations. RESULTS A total of 111/118 nasopharyngeal swabs were in complete agreement with the Sanger sequencing, whereas the remaining seven samples were not amplified due to the low viral load. The evaluation of the ability of the assay to detect the E484Q mutation was performed using a viral isolate of the SARS-CoV-2 Kappa variant, showing concordance in 15/15 samples. Simplexa® SARS-CoV-2 Variant Direct assay was able to detect mutation pattern of Alpha, Beta, Gamma, Delta, and Omicron variants with 100% specificity and 94% sensitivity, whereas 100% sensitivity and specificity for the Kappa variant was observed. CONCLUSION The assay can be useful to obtain faster results, contributing to a prompt surveillance of SARS-CoV-2 variants; however, it requires to be confirmed by the Sanger method, especially in the case of pattern of mutations that are different from those expected and also requires updates as new variants emerge.
Collapse
|
16
|
Evaluation of a commercial SARS-CoV-2 multiplex PCR genotyping assay for variant identification in resource-scarce settings. PLoS One 2022; 17:e0269071. [PMID: 35749403 PMCID: PMC9231807 DOI: 10.1371/journal.pone.0269071] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 05/13/2022] [Indexed: 11/24/2022] Open
Abstract
The rapid emergence and spread of numerous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants across the globe underscores the crucial need for continuous SARS-CoV-2 surveillance to ensure that potentially more pathogenic variants are detected early and contained. Whole genome sequencing (WGS) is currently the gold standard for COVID-19 surveillance; however, it remains cost-prohibitive and requires specialized technical skills. To increase surveillance capacity, especially in resource-scarce settings, supplementary methods that are cost- and time-effective are needed. Real-time multiplex PCR genotyping assays offer an economical and fast solution for screening circulating and emerging variants while simultaneously complementing existing WGS approaches. In this study we evaluated the AllplexTM SARS-CoV-2 Variants II multiplex real-time PCR genotyping assay, Seegene (South Korea), and implemented it in retrospectively characterizing circulating SARS-CoV-2 variants in a rural South African setting between April and October 2021, prior to the emergence of the Omicron variant in South Africa. The AllplexTM SARS-CoV-2 Variants II real-time PCR assay demonstrated perfect concordance with whole-genome sequencing in detecting Beta and Delta variants and exhibited high specificity, sensitivity and reproducibility. Implementation of the assay in characterization of SARS-CoV-2 variants between April and October 2021 in a rural South African setting revealed a rapid shift from the Beta to the Delta variant between April and June. All specimens successfully genotyped in April were Beta variants and the Delta variant was not detected until May. By June, 78% of samples genotyped were Delta variants and in July >95% of all genotyped samples were Delta variants. The Delta variant continued to predominate through to the end of our analysis in October 2021. Taken together, a commercial SARS-CoV-2 variant genotyping assay detected the rapid rate at which the Delta variant displaced the Beta variant in Limpopo, an under-monitored province in South Africa. Such assays provide a quick and cost-effective method of monitoring circulating variants and should be used to complement genomic sequencing for COVID-19 surveillance especially in resource-scarce settings.
Collapse
|
17
|
An updated review of SARS-CoV-2 detection methods in the context of a novel coronavirus pandemic. Bioeng Transl Med 2022; 8:e10356. [PMID: 35942232 PMCID: PMC9349698 DOI: 10.1002/btm2.10356] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/05/2022] [Accepted: 05/07/2022] [Indexed: 01/21/2023] Open
Abstract
The World Health Organization has reported approximately 430 million confirmed cases of coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), worldwide, including nearly 6 million deaths, since its initial appearance in China in 2019. While the number of diagnosed cases continues to increase, the need for technologies that can accurately and rapidly detect SARS-CoV-2 virus infection at early phases continues to grow, and the Federal Drug Administration (FDA) has licensed emergency use authorizations (EUAs) for virtually hundreds of diagnostic tests based on nucleic acid molecules and antigen-antibody serology assays. Among them, the quantitative real-time reverse transcription PCR (qRT-PCR) assay is considered the gold standard for early phase virus detection. Unfortunately, qRT-PCR still suffers from disadvantages such as the complex test process and the occurrence of false negatives; therefore, new nucleic acid detection devices and serological testing technologies are being developed. However, because of the emergence of strongly infectious mutants of the new coronavirus, such as Alpha (B.1.1.7), Delta (B.1.617.2), and Omicron (B.1.1.529), the need for the specific detection of mutant strains is also increasing. Therefore, this article reviews nucleic acid- and antigen-antibody-based serological assays, and compares the performance of some of the most recent FDA-approved and literature-reported assays and associated kits for the specific testing of new coronavirus variants.
Collapse
|
18
|
A robust, highly multiplexed mass spectrometry assay to identify SARS-CoV-2 variants. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2022:2022.05.28.22275691. [PMID: 35665019 PMCID: PMC9164449 DOI: 10.1101/2022.05.28.22275691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants are characterized by differences in transmissibility and response to therapeutics. Therefore, discriminating among them is vital for surveillance, infection prevention, and patient care. While whole viral genome sequencing (WGS) is the "gold standard" for variant identification, molecular variant panels have become increasingly available. Most, however, are based on limited targets and have not undergone comprehensive evaluation. We assessed the diagnostic performance of the highly multiplexed Agena MassARRAY ® SARS-CoV-2 Variant Panel v3 to identify variants in a diverse set of 391 SARS-CoV-2 clinical RNA specimens collected across our health systems in New York City, USA as well as in Bogotá, Colombia (September 2, 2020 - March 2, 2022). We demonstrate almost perfect levels of interrater agreement between this assay and WGS for 9 of 11 variant calls (κ ≥ 0.856) and 25 of 30 targets (κ ≥ 0.820) tested on the panel. The assay had a high diagnostic sensitivity (≥93.67%) for contemporary variants (e.g., Iota, Alpha, Delta, Omicron [BA.1 sublineage]) and a high diagnostic specificity for all 11 variants (≥96.15%) and all 30 targets (≥94.34%) tested. Moreover, we highlight distinct target patterns that can be utilized to identify variants not yet defined on the panel including the Omicron BA.2 and other sublineages. These findings exemplify the power of highly multiplexed diagnostic panels to accurately call variants and the potential for target result signatures to elucidate new ones. Importance The continued circulation of SARS-CoV-2 amidst limited surveillance efforts and inconsistent vaccination of populations has resulted in emergence of variants that uniquely impact public health systems. Thus, in conjunction with functional and clinical studies, continuous detection and identification are quintessential to inform diagnostic and public health measures. Furthermore, until WGS becomes more accessible in the clinical microbiology laboratory, the ideal assay for identifying variants must be robust, provide high resolution, and be adaptable to the evolving nature of viruses like SARS-CoV-2. Here, we highlight the diagnostic capabilities of a highly multiplexed commercial assay to identify diverse SARS-CoV-2 lineages that circulated at over September 2, 2020 - March 2, 2022 among patients seeking care at our health systems. This assay demonstrates variant-specific signatures of nucleotide/amino acid polymorphisms and underscores its utility for detection of contemporary and emerging SARS-CoV-2 variants of concern.
Collapse
|