1
|
Liang J, Dong S, Tan X, Gong J, Chen X, Zhou Z, Li G. A high-sensitivity label-free electrochemical aptasensor for point-of-care measurements of low-density lipoprotein in plasma based on aptamer and MXene-CMCS-Hemin nanocomposites. Bioelectrochemistry 2025; 165:108972. [PMID: 40138878 DOI: 10.1016/j.bioelechem.2025.108972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Revised: 03/12/2025] [Accepted: 03/13/2025] [Indexed: 03/29/2025]
Abstract
Cardiovascular disease (CVD) remains a significant worldwide health challenge, with mortality rates rising rapidly. Low-density lipoprotein (LDL) is a crucial serum biomarker for the early diagnosis of CVD, which can significantly improve outcomes and reduce mortality. Herein, a label-free electrochemical aptasensor for rapid detection of LDL was developed based on the titanium carbide-carboxymethyl chitosan-hemin (MXene-CMCS-Hemin) nanocomposites as the electrochemical signal probe. Firstly, gold nanoparticles (Au NPs) were electrodeposited onto a screen-printed carbon electrode (SPCE) to form a conductive substrate. Subsequently, the MXene-CMCS-Hemin nanocomposites were anchored onto the Au NPs/SPCE surface. Then LDLApt was immobilized on the surface of MXene-CMCS-Hemin/Au NPs/SPCE to construct the electrochemical aptasensor. When LDL specifically bound with the LDLApt to form LDL-LDLApt complexes, hindering the electron transfer and reducing the Hemin oxidation current, LDL detection can be achieved via differential pulse voltammetry (DPV). Under optimal circumstances, the changes of Hemin's oxidation current showed a good linear response with LDL concentration in the range of 0.1-4.0 μmol/L with a detection limit of 0.095 μmol/L (S/N = 3). The aptasensor demonstrated good performance with the relative errors of 0.60 % to 6.58 % for the direct detection of LDL in human serum samples, which offers a novel tool for the clinical diagnosis of CVD.
Collapse
Affiliation(s)
- Jintao Liang
- School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi 541004, People's Republic of China
| | - Shuaikang Dong
- School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi 541004, People's Republic of China
| | - Xiaohong Tan
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong 525000, People's Republic of China
| | - Junyan Gong
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong 525000, People's Republic of China
| | - Xuyang Chen
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong 525000, People's Republic of China
| | - Zhide Zhou
- School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi 541004, People's Republic of China.
| | - Guiyin Li
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong 525000, People's Republic of China.
| |
Collapse
|
2
|
Mirzazadeh J, Majidi MR, Norouzi P, Faridi-Majidi R, Asadpour-Zeynali K. Non-invasive and probeless rapid in-vitro monitoring and quantification of HUVECs counts based on FFT impedimetery. BIOIMPACTS : BI 2023; 14:28854. [PMID: 38938755 PMCID: PMC11199931 DOI: 10.34172/bi.2023.28854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 08/21/2023] [Accepted: 09/12/2023] [Indexed: 06/29/2024]
Abstract
Introduction The endothelial cells derived from the human vein cord (HUVECs) are used as in-vitro models for studying cellular and molecular pathophysiology, drug and hormones transport mechanisms, or pathways. In these studies, the proliferation and quantity of cells are important features that should be monitored and assessed regularly. So rapid, easy, noninvasive, and inexpensive methods are favorable for this purpose. Methods In this work, a novel method based on fast Fourier transform square-wave voltammetry (FFTSWV) combined with a 3D printed electrochemical cell including two inserted platinum electrodes was developed for non-invasive and probeless rapid in-vitro monitoring and quantification of human umbilical vein endothelial cells (HUVECs). The electrochemical cell configuration, along with inverted microscope images, provided the capability of easy use, online in-vitro monitoring, and quantification of the cells during proliferation. Results HUVECs were cultured and proliferated at defined experimental conditions, and standard cell counts in the initial range of 12 500 to 175 000 were prepared and calibrated by using a hemocytometer (Neubauer chamber) counting for electrochemical measurements. The optimum condition, for FFTSWV at a frequency of 100 Hz and 5 mV amplitude, were found to be a safe electrochemical measurement in the cell culture medium. In each run, the impedance or admittance measurement was measured in a 5 seconds time window. The total measurements were fulfilled at 5, 24, and 48 hours after the seeding of the cells, respectively. The recorded microscopic images before every electrochemical assay showed the conformity of morphology and objective counts of cells in every plate well. The proposed electrochemical method showed dynamic linearity in the range of 12 500-265 000 HUVECs 48 hours after the seeding of cells. Conclusion The proposed electrochemical method can be used as a simple, fast, and noninvasive technique for tracing and monitoring of HUVECs population in in-vitro studies. This method is highly cheap in comparison with other traditional tools. The introduced configuration has the versatility to develop electrodes for the study of various cells and the application of other electrochemical designations.
Collapse
Affiliation(s)
- Jalil Mirzazadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| | - Parviz Norouzi
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Reza Faridi-Majidi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Karim Asadpour-Zeynali
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
- Pharmaceutical Analysis Research Center, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz 51664, Iran
| |
Collapse
|
3
|
Visualization of electrochemical reactions on microelectrodes using light-addressable potentiometric sensor imaging. Anal Chim Acta 2022; 1224:340237. [DOI: 10.1016/j.aca.2022.340237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 07/12/2022] [Accepted: 08/01/2022] [Indexed: 11/20/2022]
|
4
|
LI G, WANG B, ZHAO L, SHI X, WU G, CHEN W, SUN L, LIANG J, ZHOU Z. Label-free detection of glypican-3 using reduced graphene oxide /polyetherimide/gold nanoparticles enhanced aptamer specific sensing interface on light-addressable potentiometric sensor. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
Meng Y, Chen F, Wu C, Krause S, Wang J, Zhang DW. Light-Addressable Electrochemical Sensors toward Spatially Resolved Biosensing and Imaging Applications. ACS Sens 2022; 7:1791-1807. [PMID: 35762514 DOI: 10.1021/acssensors.2c00940] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The light-addressable electrochemical sensor (LAES) is a recently emerged bioanalysis technique combining electrochemistry with the photoelectric effect in a semiconductor. In an LAES, a semiconductor substrate is illuminated locally to generate charge carriers in a well-defined area, thereby confining the electrochemical process to a target site. Benefiting from the unique light addressability, an LAES can not only detect multiple analytes in parallel within a single sensor plate but also act as a bio(chemical) imaging sensor to visualize the two-dimensional distribution of specific analytes. An LAES usually has three working modes: a potentiometric mode using light-addressable potentiometric sensors (LAPS) and an impedance mode using scanning photoinduced impedance microscopy (SPIM), while an amperometric mode refers to light-addressable electrochemistry (LAE) and photoelectrochemical (PEC) sensing. In this review, we describe the detection principles of each mode of LAESs and the concept of light addressability. In addition, we highlight the recent progress and advance of LAESs in spatial resolution, sensor system design, multiplexed detection, and bio(chemical) imaging applications. An outlook on current research challenges and future prospects is also presented.
Collapse
Affiliation(s)
- Yao Meng
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Fangming Chen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Chunsheng Wu
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Steffi Krause
- School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS, U.K
| | - Jian Wang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.,Key Laboratory of Environment and Genes Related to Diseases (Xi'an Jiaotong University), Ministry of Education of China, Xi'an, 710061, China
| | - De-Wen Zhang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.,Key Laboratory of Environment and Genes Related to Diseases (Xi'an Jiaotong University), Ministry of Education of China, Xi'an, 710061, China
| |
Collapse
|
6
|
Yoshinobu T, Miyamoto KI. Efficient Illumination for a Light-Addressable Potentiometric Sensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:4541. [PMID: 35746324 PMCID: PMC9227191 DOI: 10.3390/s22124541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/13/2022] [Accepted: 06/15/2022] [Indexed: 06/15/2023]
Abstract
A light-addressable potentiometric sensor (LAPS) is a chemical sensor that is based on the field effect in an electrolyte-insulator-semiconductor structure. It requires modulated illumination for generating an AC photocurrent signal that responds to the activity of target ions on the sensor surface. Although high-power illumination generates a large signal, which is advantageous in terms of the signal-to-noise ratio, excess light power can also be harmful to the sample and the measurement. In this study, we tested different waveforms of modulated illuminations to find an efficient illumination for a LAPS that can enlarge the signal as much as possible for the same input light power. The results showed that a square wave with a low duty ratio was more efficient than a sine wave by a factor of about two.
Collapse
Affiliation(s)
- Tatsuo Yoshinobu
- Department of Biomedical Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Ko-ichiro Miyamoto
- Department of Electronic Engineering, Tohoku University, Sendai 980-8579, Japan;
| |
Collapse
|
7
|
Simultaneous In Situ Imaging of pH and Surface Roughening during the Progress of Crevice Corrosion of Stainless Steel. SENSORS 2022; 22:s22062246. [PMID: 35336414 PMCID: PMC8952019 DOI: 10.3390/s22062246] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/11/2022] [Accepted: 03/12/2022] [Indexed: 12/13/2022]
Abstract
Stainless steel plays an important role in industry due to its anti-corrosion characteristic. It is known, however, that local corrosion can damage stainless steel under certain conditions. In this study, we developed a novel measurement system to observe crevice corrosion, which is a local corrosion that occurs inside a narrow gap. In addition to pH imaging inside the crevice, another imaging technique using an infrared light was combined to simultaneously visualize surface roughening of the test piece. According to experimental results, the lowering of local pH propagated inside the crevice, and after that, the surface roughening started and expanded due to propagation of corrosion. The real-time measurement of the pH distribution and the surface roughness can be a powerful tool to investigate the crevice corrosion.
Collapse
|
8
|
Li X, Liu S, Tan J, Wu C. Light-Addressable Potentiometric Sensors in Microfluidics. Front Bioeng Biotechnol 2022; 10:833481. [PMID: 35265603 PMCID: PMC8899193 DOI: 10.3389/fbioe.2022.833481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 01/25/2022] [Indexed: 11/30/2022] Open
Abstract
The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor based on the field-effect principle of semiconductors. It is able to sense the change of Nernst potential on the sensor surface, and the measuring area can be controlled by the illumination of a movable light. Due to the unique light-addressable ability of the LAPS, the chemical imaging system constructed with the LAPS can realize the two-dimensional image distribution detection of chemical/biomass. In this review, the advantages of the LAPS as a sensing unit of the microelectrochemical analysis system are summarized. Then, the most recent advances in the development of the LAPS analysis system are explained and discussed. In particular, this review focused on the research of ion diffusion, enzymatic reaction, microbial metabolism, and droplet microfluidics using the LAPS analysis system. Finally, the development trends and prospects of the LAPS analysis system are illustrated.
Collapse
Affiliation(s)
- Xueliang Li
- School of Mechanical and Electrical Engineering, Zhoukou Normal University, Zhoukou, China
| | - Shibin Liu
- College of Electronics and Information, Northwestern Polytechnical University, Xi'an, China
| | - Jie Tan
- College of Electronics and Information, Northwestern Polytechnical University, Xi'an, China
| | - Chunsheng Wu
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
9
|
Joly M, Deng T, Morhart TA, Wells G, Achenbach S, Bégin-Drolet A, Greener J. Scanning Aperture Approach for Spatially Selective ATR-FTIR Spectroscopy: Application to Microfluidics. Anal Chem 2021; 93:14076-14087. [PMID: 34636233 DOI: 10.1021/acs.analchem.1c01614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
We present a novel spectroscopy accessory that can easily convert any Fourier transform infrared (FTIR) spectrometer into a fully automated mapping and assaying system. The accessory uses a multiridge attenuated total reflection (ATR) wafer as the sensing element coupled with a moving aperture that is used to select the regions of interest on the wafer. In this demonstration, the accessory is combined with a series of parallel micropatterned channels, which are positioned co-linear with the light-coupling ridges on the opposite side of the ATR wafer. The ATR spectroscopy microfluidic assay accessory (ASMAA) was used in continuous mapping mode to scan perpendicular to the ATR ridges, revealing complex but repeatable oscillations in the spectral intensities. To understand this behavior, the light path through the optical components was simulated with consideration of the aperture position, ridge-to-channel alignment, and excitation beam profile. With this approach, the simulation reproduced the experimental mapping results and provided evidence that the measurement position and area changed with the aperture position. To demonstrate the assay mode, we obtained spectra along the centerline of individual microchannels and determined noise baselines and limits of detection.
Collapse
Affiliation(s)
- Maxime Joly
- Département de génie mécanique, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Tianyang Deng
- Département de chimie, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Tyler A Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada.,Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| | - Garth Wells
- Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - André Bégin-Drolet
- Département de génie mécanique, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Jesse Greener
- Département de chimie, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada.,CHU de Québec, centre de recherche, Université Laval, 10 rue de l'Espinay, Québec, QC G1L 3L5, Canada
| |
Collapse
|
10
|
Liang T, Jiang N, Zhou S, Wang X, Xu Y, Wu C, Kirsanov D, Legin A, Wan H, Wang P. Multiplexed all-solid-state ion-sensitive light-addressable potentiometric sensor (ISLAPS) system based on silicone-rubber for physiological ions detection. Anal Chim Acta 2021; 1179:338603. [PMID: 34535249 DOI: 10.1016/j.aca.2021.338603] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 04/14/2021] [Accepted: 04/30/2021] [Indexed: 10/21/2022]
Abstract
Light-addressable potentiometric sensor (LAPS) has been widely used in biomedical applications since its advent. As a member of the potentiometric sensors, ion-sensitive LAPS (ISLAPS) can be obtained by modifying ion selective sensing membrane on the sensor surface. Compared with the conventional ion-selective electrodes (ISEs) with liquid contact, the all-solid-state ISEs have more advantages such as easy maintenance, more convenient for miniaturization and practical applications. However, the commonly used ion-sensitive membrane (ISM) matrix like PVC has many limitations such as poor adhesion to silicone-based sensor and easy overflow of the plasticizer from the membrane. In this work, LAPS was combined with a variety of ionophore-doped all-solid-state silicone-rubber ISMs for the first time, to establish a program-controlled multiplexed ISLAPS system for physiological ions (Na+, K+, Ca2+ and H+) detection. The silicone-rubber ISMs have better adhesion to silicon-based sensors without containing plasticizers, which can avoid the plasticizer pollution and improve the long-term stability. A layer of poly(3-octylthiophene-2,5-diyl) (P3OT) was pre-modified on the sensor surface to inhibit the formation of an aqueous layer and improve the sensor lifetime. With the aid of a translation stage, the light spot automatically illuminated the detection sites in sequence, and the response of the four ions could be obtained in one measurement within 1 min. The proposed multiplexed ISLAPS has good sensitivity with micromolar limit of detection (LOD), good selectivity and long-term stability (more than 3 months). The results of the real Dulbecco's Modified Eagle Medium (DMEM) sample detection proved that the ISLAPS system can be used for the physiological ions detection, and is promising to realize a multi-parameter microphysiometer.
Collapse
Affiliation(s)
- Tao Liang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Nan Jiang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Shuqi Zhou
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Xinyi Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yingke Xu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Chunsheng Wu
- Institute of Medical Engineering, School of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Dmitry Kirsanov
- Institute of Chemistry, Mendeleev Center, St. Petersburg State University, St. Petersburg, 199034, Russia
| | - Andrey Legin
- Institute of Chemistry, Mendeleev Center, St. Petersburg State University, St. Petersburg, 199034, Russia
| | - Hao Wan
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| | - Ping Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| |
Collapse
|
11
|
Yang CM, Yen T, Liu HL, Lin YJ, Lin PY, Tsui LS, Chen CH, Chen YP, Hsu YC, Lo CH, Wu TR, Lai HC, Chin WC, Pijanowska DG, Hwang TL, Lai CS. A real-time mirror-LAPS mini system for dynamic chemical imaging and cell acidification monitoring. SENSORS AND ACTUATORS B: CHEMICAL 2021; 341:130003. [DOI: 10.1016/j.snb.2021.130003] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
|
12
|
Wang J, Chen F, Guo Q, Meng Y, Jiang M, Wu C, Zhuang J, Zhang DW. Light-Addressable Square Wave Voltammetry (LASWV) Based on a Field-Effect Structure for Electrochemical Sensing and Imaging. ACS Sens 2021; 6:1636-1642. [PMID: 33832225 DOI: 10.1021/acssensors.1c00170] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Here, we describe a new photoelectrochemical imaging method termed light-addressable square wave voltammetry (LASWV). It measures local SWV currents at an unstructured electrolyte/insulator/semiconductor (EIS) field-effect substrate by illuminating and addressing the substrate with an intensity-constant laser. Due to the continuous generation of charge carriers in the light-irradiated semiconductor, the drift and diffusion of photoinjected carriers within the semiconductor bulk would slow down the equilibrium processes of charge and discharge in one potential pulse cycle. Therefore, even though SWV is sampled at the end of the direct and reverse pulses to reject capacitive currents, in our approach, photoinduced capacitive current can still be detected as an effective sensory signal. The obtained current-potential (I-V) curve shows a typical shape corresponding to the accumulation, depletion, and inversion regions of field-effect devices. We demonstrated that LASWV can be used as a field-effect chemical sensor to measure the solution pH and monitor enzymatic reactions. More importantly, since the charge carriers are only generated in the illuminated area, the laser spot in the device can be used as a virtual probe to record local electrochemical properties such as impedance with microresolution.
Collapse
Affiliation(s)
- Jian Wang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
- Key Laboratory of Environment and Genes Related to Diseases (Xi’an Jiaotong University), Ministry of Education of China, Xi’an 710061, China
| | - Fangming Chen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
| | - Qin Guo
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
| | - Yao Meng
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
| | - Mingrui Jiang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
| | - Chunsheng Wu
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
| | - Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi’an Jiaotong University, Xi’an 710049, China
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - De-Wen Zhang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi’an Jiaotong University, Xi’an 710061, China
- Key Laboratory of Environment and Genes Related to Diseases (Xi’an Jiaotong University), Ministry of Education of China, Xi’an 710061, China
| |
Collapse
|
13
|
Peng HY, Yang CM, Chen YP, Liu HL, Chen TC, Pijanowska DG, Chu PY, Hsieh CH, Wu MH. An integrated actuating and sensing system for light-addressable potentiometric sensor (LAPS) and light-actuated AC electroosmosis (LACE) operation. BIOMICROFLUIDICS 2021; 15:024109. [PMID: 33868536 PMCID: PMC8043754 DOI: 10.1063/5.0040910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 03/24/2021] [Indexed: 06/12/2023]
Abstract
To develop a lab on a chip (LOC) integrated with both sensor and actuator functions, a novel two-in-one system based on optical-driven manipulation and sensing in a microfluidics setup based on a hydrogenated amorphous silicon (a-Si:H) layer on an indium tin oxide/glass is first realized. A high-intensity discharge xenon lamp functioned as the light source, a chopper functioned as the modulated illumination for a certain frequency, and a self-designed optical path projected on the digital micromirror device controlled by the digital light processing module was established as the illumination input signal with the ability of dynamic movement of projected patterns. For light-addressable potentiometric sensor (LAPS) operation, alternating current (AC)-modulated illumination with a frequency of 800 Hz can be generated by the rotation speed of the chopper for photocurrent vs bias voltage characterization. The pH sensitivity, drift coefficient, and hysteresis width of the Si3N4 LAPS are 52.8 mV/pH, -3.2 mV/h, and 10.5 mV, respectively, which are comparable to the results from the conventional setup. With an identical two-in-one system, direct current illumination without chopper rotation and an AC bias voltage can be provided to an a-Si:H chip with a manipulation speed of 20 μm/s for magnetic beads with a diameter of 1 μm. The collection of magnetic beads by this light-actuated AC electroosmosis (LACE) operation at a frequency of 10 kHz can be easily realized. A fully customized design of an illumination path with less decay can be suggested to obtain a high efficiency of manipulation and a high signal-to-noise ratio of sensing. With this proposed setup, a potential LOC system based on LACE and LAPS is verified with the integration of a sensor and an actuator in a microfluidics setup for future point-of-care testing applications.
Collapse
Affiliation(s)
| | - Chia-Ming Yang
- Authors to whom correspondence should be addressed:. Tel.: +886-3-2118800 ext.: 5960 and . Tel.: +886-3-2118800 ext.: 3599
| | - Yu-Ping Chen
- Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan City 333, Taiwan
| | - Hui-Ling Liu
- Department of Electronic Engineering, Chang Gung University, Taoyuan City 333, Taiwan
| | - Tsung-Cheng Chen
- Department of Electronic Engineering, Chang Gung University, Taoyuan City 333, Taiwan
| | - Dorota G. Pijanowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Science, IBBE PAS 02-109, Warsaw, Poland
| | - Po-Yu Chu
- Ph.D. Program in Biomedical Engineering, Chang Gung University, Taoyuan City 333, Taiwan
| | | | - Min-Hsien Wu
- Authors to whom correspondence should be addressed:. Tel.: +886-3-2118800 ext.: 5960 and . Tel.: +886-3-2118800 ext.: 3599
| |
Collapse
|
14
|
Yang CM, Chen CH, Akuli N, Yen TH, Lai CS. A revised manuscript submitted to sensors and actuators B: Chemical illumination modification from an LED to a laser to improve the spatial resolution of IGZO thin film light-addressable potentiometric sensors in pH detections. SENSORS AND ACTUATORS B: CHEMICAL 2021; 329:128953. [DOI: 10.1016/j.snb.2020.128953] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
|
15
|
Wei X, Zhuang L, Li H, He C, Wan H, Hu N, Wang P. Advances in Multidimensional Cardiac Biosensing Technologies: From Electrophysiology to Mechanical Motion and Contractile Force. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2005828. [PMID: 33230867 DOI: 10.1002/smll.202005828] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Indexed: 06/11/2023]
Abstract
Cardiovascular disease is currently a leading killer to human, while drug-induced cardiotoxicity remains the main cause of the withdrawal and attrition of drugs. Taking clinical correlation and throughput into account, cardiomyocyte is perfect as in vitro cardiac model for heart disease modeling, drug discovery, and cardiotoxicity assessment by accurately measuring the physiological multiparameters of cardiomyocytes. Remarkably, cardiomyocytes present both electrophysiological and biomechanical characteristics due to the unique excitation-contraction coupling, which plays a significant role in studying the cardiomyocytes. This review mainly focuses on the recent advances of biosensing technologies for the 2D and 3D cardiac models with three special properties: electrophysiology, mechanical motion, and contractile force. These high-performance multidimensional cardiac models are popular and effective to rebuild and mimic the heart in vitro. To help understand the high-quality and accurate physiologies, related detection techniques are highly demanded, from microtechnology to nanotechnology, from extracellular to intracellular recording, from multiple cells to single cell, and from planar to 3D models. Furthermore, the characteristics, advantages, limitations, and applications of these cardiac biosensing technologies, as well as the future development prospects should contribute to the systematization and expansion of knowledge.
Collapse
Affiliation(s)
- Xinwei Wei
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, 310027, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Liujing Zhuang
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, 310027, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Hongbo Li
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510006, China
| | - Chuanjiang He
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, 310027, China
| | - Hao Wan
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, 310027, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Ning Hu
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510006, China
| | - Ping Wang
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, 310027, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| |
Collapse
|
16
|
Wang J, Tian Y, Chen F, Chen W, Du L, He Z, Wu C, Zhang DW. Scanning Electrochemical Photometric Sensors for Label-Free Single-Cell Imaging and Quantitative Absorption Analysis. Anal Chem 2020; 92:9739-9744. [PMID: 32437169 DOI: 10.1021/acs.analchem.0c01118] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A new photoelectrochemical imaging method termed scanning electrochemical photometric sensor (SEPS) is proposed in this work. It was derived from light-addressable potentiometric sensor (LAPS) and scanning photoinduced impedance microscopy (SPIM) using a front-side laser illumination at a field-effect structure. When the laser beam scans across the sensor substrate, local photocurrent changes at inversion due to the light absorption of analytes can be recorded. It will be shown that SEPS could be used for label-free living cell imaging with micro-resolution as well as real-time quantitative absorption analysis, which would broaden the applications of traditional LAPS/SPIM from potentiometric/impedance measurements to local optical analysis.
Collapse
Affiliation(s)
- Jian Wang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Yulan Tian
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Fangming Chen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Wei Chen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Liping Du
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Zhiyuan He
- Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Chunsheng Wu
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - De-Wen Zhang
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| |
Collapse
|