1
|
Atkinson N, Morhart TA, Wells G, Flaman GT, Petro E, Read S, Rosendahl SM, Burgess IJ, Achenbach S. Microfabrication Process Development for a Polymer-Based Lab-on-Chip Concept Applied in Attenuated Total Reflection Fourier Transform Infrared Spectroelectrochemistry. Sensors (Basel) 2023; 23:6251. [PMID: 37514546 PMCID: PMC10383751 DOI: 10.3390/s23146251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 06/27/2023] [Accepted: 07/03/2023] [Indexed: 07/30/2023]
Abstract
Micro electro-mechanical systems (MEMS) combining sensing and microfluidics functionalities, as are common in Lab-on-Chip (LoC) devices, are increasingly based on polymers. Benefits of polymers include tunable material properties, the possibility of surface functionalization, compatibility with many micro and nano patterning techniques, and optical transparency. Often, additional materials, such as metals, ceramics, or silicon, are needed for functional or auxiliary purposes, e.g., as electrodes. Hybrid patterning and integration of material composites require an increasing range of fabrication approaches, which must often be newly developed or at least adapted and optimized. Here, a microfabrication process concept is developed that allows one to implement attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and electrochemistry on an LoC device. It is designed to spatially resolve chemical sensitivity and selectivity, which are instrumental for the detection of chemical distributions, e.g., during on-flow chemical and biological reaction chemistry. The processing sequence involves (i) direct-write and soft-contact UV lithography in SUEX dry resist and replication in polydimethylsiloxane (PDMS) elastomers as the fluidic structure; (ii) surface functionalization of PDMS with oxygen plasma, 3-aminopropyl-triethoxysilane (APTES), and a UV-curable glue (NOA 73) for bonding the fluidic structure to the substrate; (iii) double-sided patterning of silicon nitride-coated silicon wafers serving as the ATR-FTIR-active internal reflection element (IRE) on one side and the electrode-covered substrate for microfluidics on the back side with lift-off and sputter-based patterning of gold electrodes; and (iv) a custom-designed active vacuum positioning and alignment setup. Fluidic channels of 100 μm height and 600 μm width in 5 mm thick PDMS were fabricated on 2" and 4" demonstrators. Electrochemistry on-chip functionality was demonstrated by cyclic voltammetry (CV) of redox reactions involving iron cyanides in different oxidation states. Further, ATR-FTIR measurements of laminar co-flows of H2O and D2O demonstrated the chemical mapping capabilities of the modular fabrication concept of the LoC devices.
Collapse
Affiliation(s)
- Noah Atkinson
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Tyler A Morhart
- Synchrotron Laboratory for Micro and Nano Devices, Canadian Light Source Inc., Saskatoon, SK S7N 2V3, Canada
| | - Garth Wells
- Synchrotron Laboratory for Micro and Nano Devices, Canadian Light Source Inc., Saskatoon, SK S7N 2V3, Canada
| | - Grace T Flaman
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
| | - Eric Petro
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Stuart Read
- Mid Infrared Spectromicroscopy Facility, Canadian Light Source Inc., Saskatoon, SK S7N 2V3, Canada
| | - Scott M Rosendahl
- Mid Infrared Spectromicroscopy Facility, Canadian Light Source Inc., Saskatoon, SK S7N 2V3, Canada
| | - Ian J Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| |
Collapse
|
2
|
Flaman GT, Boyle ND, Vermelle C, Morhart TA, Ramaswami B, Read S, Rosendahl SM, Wells G, Newman LP, Atkinson N, Achenbach S, Burgess IJ. Chemical Imaging of Mass Transport Near the No-Slip Interface of a Microfluidic Device using Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy. Anal Chem 2023; 95:4940-4949. [PMID: 36880970 DOI: 10.1021/acs.analchem.2c04880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023]
Abstract
Mass transport in geometrically confined environments is fundamental to microfluidic applications. Measuring the distribution of chemical species on flow requires the use of spatially resolved analytical tools compatible with microfluidic materials and designs. Here, the implementation of an attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) imaging (macro-ATR) approach for chemical mapping of species in microfluidic devices is described. The imaging method is configurable between a large field of view, single-frame imaging, and the use of image stitching to build composite chemical maps. Macro-ATR is used to quantify transverse diffusion in the laminar streams of coflowing fluids in dedicated microfluidic test devices. It is demonstrated that the ATR evanescent wave, which primarily probes the fluid within ∼500 nm of the channel surface, provides accurate quantification of the spatial distribution of species in the entire microfluidic device cross section. This is the case when flow and channel conditions promote vertical concentration contours in the channel as verified by three-dimensional numeric simulations of mass transport. Furthermore, the validity of treating the mass transport problem in a simplified and faster approach using reduced dimensionality numeric simulations is described. Simplified one-dimensional simulations, for the specific parameters used herein, overestimate diffusion coefficients by a factor of approximately 2, whereas full three-dimensional simulations accurately agree with experimental results.
Collapse
Affiliation(s)
- Grace T Flaman
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9 Canada
| | - Nicole D Boyle
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9 Canada
| | - Cyprien Vermelle
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A9 Canada
| | - Tyler A Morhart
- Canadian Light Source Inc., Saskatoon, Saskatchewan S7N 2V3 Canada
| | - Bdhanya Ramaswami
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9 Canada
| | - Stuart Read
- Canadian Light Source Inc., Saskatoon, Saskatchewan S7N 2V3 Canada
| | | | - Garth Wells
- Canadian Light Source Inc., Saskatoon, Saskatchewan S7N 2V3 Canada
| | - Liam P Newman
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A9 Canada
| | - Noah Atkinson
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A9 Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A9 Canada
| | - Ian J Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9 Canada
| |
Collapse
|
3
|
Morhart TA, Tu K, Read ST, Rosendahl SM, Wells G, Achenbach S, Burgess IJ. Surface enhanced infrared spectroelectrochemistry using a microband electrode. CAN J CHEM 2021. [DOI: 10.1139/cjc-2021-0183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The successful use of a microband electrode printed on a silicon internal reflection element to perform time resolved infrared spectroscopy is described. Decreasing the critical dimension of the microband electrode to several hundred micrometers provides a sub-microsecond time constant in a Kretschmann configured spectroelectrochemical cell. The high brilliance of synchrotron sourced infrared radiation has been combined with a specially designed horizontal attenuated total reflectance (ATR) microscope to focus the infrared beam on the microband electrode. The first use of a sub-microsecond time constant working electrode for ATR surface enhanced infrared absorption spectroscopy (ATR-SEIRAS) is reported. Measurements show that the advantage afforded by the high brilliance of the synchrotron source is at least partially offset by increased noise from the experimental floor. The test system was the potential induced desorption of an adsorbed monolayer of 4-methoxypyridine (MOP) as measured using step-scan interferometry. Based on diffusion considerations alone, the expected time scale of the process was less than 10 microseconds but was experimentally measured to be three orders of magnitude slower. A defect-mediated dissolution of the condensed film is speculated to be the underlying cause of the unexpected slow kinetics.
Collapse
Affiliation(s)
- Tyler A. Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
- Canadian Light Source, Saskatoon, SK S7N 0X4, Canada
| | - Kaiyang Tu
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
- Canadian Light Source, Saskatoon, SK S7N 0X4, Canada
| | | | | | - Garth Wells
- Canadian Light Source, Saskatoon, SK S7N 0X4, Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Ian J. Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
| |
Collapse
|
4
|
Joly M, Deng T, Morhart TA, Wells G, Achenbach S, Bégin-Drolet A, Greener J. Scanning Aperture Approach for Spatially Selective ATR-FTIR Spectroscopy: Application to Microfluidics. Anal Chem 2021; 93:14076-14087. [PMID: 34636233 DOI: 10.1021/acs.analchem.1c01614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
We present a novel spectroscopy accessory that can easily convert any Fourier transform infrared (FTIR) spectrometer into a fully automated mapping and assaying system. The accessory uses a multiridge attenuated total reflection (ATR) wafer as the sensing element coupled with a moving aperture that is used to select the regions of interest on the wafer. In this demonstration, the accessory is combined with a series of parallel micropatterned channels, which are positioned co-linear with the light-coupling ridges on the opposite side of the ATR wafer. The ATR spectroscopy microfluidic assay accessory (ASMAA) was used in continuous mapping mode to scan perpendicular to the ATR ridges, revealing complex but repeatable oscillations in the spectral intensities. To understand this behavior, the light path through the optical components was simulated with consideration of the aperture position, ridge-to-channel alignment, and excitation beam profile. With this approach, the simulation reproduced the experimental mapping results and provided evidence that the measurement position and area changed with the aperture position. To demonstrate the assay mode, we obtained spectra along the centerline of individual microchannels and determined noise baselines and limits of detection.
Collapse
Affiliation(s)
- Maxime Joly
- Département de génie mécanique, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Tianyang Deng
- Département de chimie, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Tyler A Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada.,Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| | - Garth Wells
- Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - André Bégin-Drolet
- Département de génie mécanique, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada
| | - Jesse Greener
- Département de chimie, Faculté des sciences et de génie, Université Laval, Québec, QC G1V 0A6, Canada.,CHU de Québec, centre de recherche, Université Laval, 10 rue de l'Espinay, Québec, QC G1L 3L5, Canada
| |
Collapse
|
5
|
Tu K, Morhart TA, Read ST, Rosendahl SM, Burgess IJ. Probing Heterogeneity in Attenuated Total Reflection Surface-Enhanced Infrared Absorption Spectroscopy (ATR-SEIRAS) Response with Synchrotron Infrared Microspectroscopy. Appl Spectrosc 2021; 75:1198-1206. [PMID: 33709793 PMCID: PMC8446892 DOI: 10.1177/00037028211005817] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 03/02/2021] [Indexed: 06/12/2023]
Abstract
The heterogeneity of metal island films electrodeposited on conductive metal oxide modified internal reflection elements is shown to provide a variable attenuated total reflection surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS) response. A self-assembled monolayer of a ferrocene-terminated thiol monolayer (FcC11SH) was formed on the gold islands covering a single substrate, which was measured using both a conventional spectrometer and a custom-built horizontal microscope. Cyclic voltammetry and ATR-SEIRAS results reveal that the FcC11SH-modified substrate undergoes a reversible electron transfer and an associated re-orientation of both the ferrocene/ferrocenium headgroup and the hydrocarbon backbone. The magnitude of the absorption signal arising from the redox changes in the monolayer, as well as the IR signature arising from the ingress/egress of the perchlorate counterions, is shown to depend significantly on the size of the infrared beam spot when using a conventional Fourier transform infrared spectrometer. By performing equivalent measurements on a horizontal microscope, the primary cause of the differences in the signal level is found to be the heterogeneity in the density of gold islands on the conductive metal oxide.
Collapse
Affiliation(s)
- Kaiyang Tu
- Department of Chemistry, University of
Saskatchewan, Saskatchewan, Canada
- Canadian Light Source, Saskatoon,
Canada
| | - Tyler A. Morhart
- Department of Chemistry, University of
Saskatchewan, Saskatchewan, Canada
- Canadian Light Source, Saskatoon,
Canada
| | | | | | - Ian J. Burgess
- Department of Chemistry, University of
Saskatchewan, Saskatchewan, Canada
| |
Collapse
|
6
|
Sigrist JA, Lins ES, Morhart TA, Briggs JL, Burgess IJ. Optimization of a Commercial Variable Angle Accessory for Entry Level Users of Electrochemical Attenuated Total Reflection Surface-Enhanced Infrared Absorption Spectroscopy (ATR-SEIRAS). Appl Spectrosc 2019; 73:1394-1402. [PMID: 31219336 DOI: 10.1177/0003702819858353] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
An evaluation of several experimental aspects that can optimize electrochemical attenuated total reflection surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS) performance using a commercially available, specular reflection accessory is provided. A comparison of different silicon single-bounce internal reflection elements (IREs) is made with emphasis on different face-angled crystal (FAC) options. Selection of optimal angle of incidence for maximizing signal and minimizing noise is shown to require consideration of the optical throughput of the accessory, reflection losses at the crystal surfaces, and polarization effects. The benefits of wire-grid polarizers and antireflective (AR) coatings on the IREs is discussed. High signal-to-noise ratios can be achieved by omitting polarizers, using an AR-coated FAC with a larger face angle, and working at angles of incidence close to the maximum throughput angle of the accessory.
Collapse
Affiliation(s)
- Jessica A Sigrist
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| | - Erick S Lins
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| | - Tyler A Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| | | | - Ian J Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
7
|
Morhart TA, Read S, Wells G, Jacobs M, Rosendahl SM, Achenbach S, Burgess IJ. Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectromicroscopy Using Synchrotron Radiation and Micromachined Silicon Wafers for Microfluidic Applications. Appl Spectrosc 2018; 72:1781-1789. [PMID: 29893584 DOI: 10.1177/0003702818785640] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A custom-designed optical configuration compatible with the use of micromachined multigroove internal reflection elements (μ-groove IREs) for attenuated total reflectance Fourier transform infrared (ATR FT-IR) spectroscopy and imaging applications in microfluidic devices is described. The μ-groove IREs consist of several face-angled grooves etched into a single, monolithic silicon chip. The optical configuration permits individual grooves to be addressed by focusing synchrotron sourced IR light through a 150 µm pinhole aperture, restricting the beam spot size to a dimension smaller than that of the groove walls. The effective beam spot diameter at the ATR sampling plane is determined through deconvolution of the measured detector response and found to be 70 µm. The μ-groove IREs are highly compatible with standard photolithographic techniques as demonstrated by printing a 400 µm wide channel in an SU-8 film spin-coated on the IRE surface. Attenuated total reflection FT-IR mapping as a function of sample position across the channel illustrates the potential application of this approach for rapid prototyping of microfluidic devices.
Collapse
Affiliation(s)
- Tyler A Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| | - Stuart Read
- Canadian Light Source, Saskatoon, SK, Canada
| | - Garth Wells
- Canadian Light Source, Saskatoon, SK, Canada
| | | | | | - Sven Achenbach
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - Ian J Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
8
|
Affiliation(s)
- Tyler A. Morhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Bipinlal Unni
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Michael J. Lardner
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Ian J. Burgess
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| |
Collapse
|
9
|
Morhart TA, Quirk A, Lardner MJ, May TE, Rosendahl SM, Burgess IJ. Femtomole Infrared Spectroscopy at the Electrified Metal–Solution Interface. Anal Chem 2016; 88:9351-9354. [DOI: 10.1021/acs.analchem.6b02840] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Tyler A. Morhart
- Department
of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Amanda Quirk
- Department
of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Michael J. Lardner
- Department
of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Tim E. May
- Canadian Light Source, Saskatoon, Saskatchewan S7N 2 V3, Canada
| | | | - Ian J. Burgess
- Department
of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| |
Collapse
|