1
|
Öven EN, Genc AA, Erk N, Bouali W, Salamat Q, Soylak M. Highly sensitive electrochemical determination of cariprazine using a novel Ti 3C 2@CoAl 2O 4 nanocomposite: application to pharmaceutical and biological sample analysis. Mikrochim Acta 2025; 192:248. [PMID: 40126677 PMCID: PMC11933176 DOI: 10.1007/s00604-025-07104-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2025] [Accepted: 03/09/2025] [Indexed: 03/26/2025]
Abstract
Cariprazine (CAR) is an atypical antipsychotic drug used for the treatment of schizophrenia and bipolar disorder. This study presents the development of a novel, highly sensitive electrochemical sensor based on a Ti3C2@CoAl2O2 nanocomposite-modified glassy carbon electrode (GCE) for the detection of CAR in pharmaceutical and biological samples. The innovative Ti3C2@CoAl2O2 composite, synthesized and characterized through Fourier-transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy coupled with energy-dispersive spectroscopy, and thermogravimetric analysis, revealed exceptional structural integrity, morphology, composition, and thermal stability. The electrochemical properties of the modified electrode were evaluated using cyclic voltammetry and electrochemical impedance spectroscopy, demonstrating enhanced conductivity, an increased electroactive surface area, and reduced charge transfer resistance compared to the bare GCE. Differential pulse voltammetry was employed for CAR detection under optimized conditions, yielding a linear range of 0.2-5.6 μM with a regression equation Ipa (μA) = 0.133 CCAR (μM) + 0.09 (R2 = 0.993). The limit of detection and limit of quantification were determined as 0.02 µM and 0.07 µM, respectively, highlighting the sensor's high sensitivity. The modified electrode exhibited excellent repeatability with a relative standard deviation (RSD) of = 2.9% and reproducibility (RSD = 2.8%), along with strong selectivity against common interfering substances. The sensor was successfully applied to human blood serum, urine, and CAR tablets, achieving high recovery values (98.52-103.94%), confirming its reliability for real-sample analysis. These findings underline the novelty and potential of the Ti3C2@CoAl2O2-modified GCE as a powerful tool for the accurate, selective, and sensitive determination of CAR in clinical and pharmaceutical applications.
Collapse
Affiliation(s)
- Elif Naz Öven
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Turkey.
- The Graduate School of the Health Sciences, Ankara University, 06110, Ankara, Turkey.
| | - Asena Ayse Genc
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Turkey
- The Graduate School of the Health Sciences, Ankara University, 06110, Ankara, Turkey
| | - Nevin Erk
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Turkey.
| | - Wiem Bouali
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara, Turkey
- The Graduate School of the Health Sciences, Ankara University, 06110, Ankara, Turkey
| | - Qamar Salamat
- Department of Chemistry, Faculty of Sciences, Erciyes University, 38039, Kayseri, Turkey
| | - Mustafa Soylak
- Department of Chemistry, Faculty of Sciences, Erciyes University, 38039, Kayseri, Turkey
- Technology Research & Application Center (TAUM), Erciyes University, 38039, Kayseri, Turkey
- Turkish Academy of Sciences (TUBA), Cankaya, Ankara, Turkey
| |
Collapse
|
2
|
Yılmaz F, Shama NA, Aşır S, Çobanoğulları H, Yolaç E, Kiraz A, Göktürk I, Denizli A, Türkmen D. Gold Nanoparticle-Modified Molecularly Imprinted Polymer-Coated Pencil Graphite Electrodes for Electrochemical Detection of Bisphenol A. ACS OMEGA 2025; 10:740-753. [PMID: 39829487 PMCID: PMC11740146 DOI: 10.1021/acsomega.4c07688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2024] [Revised: 11/23/2024] [Accepted: 11/26/2024] [Indexed: 01/22/2025]
Abstract
The sensitive Bisphenol A (BPA) detection by an electrochemical sensor based on gold nanoparticle-doped molecularly imprinted polymer was successfully improved. This study describes the development of a method for BPA detection in both aqueous solution and real water samples using N-methacroyl-(L)-cysteine methyl ester and N-methacryloyl-(L)-phenylalanine methyl ester coated pencil graphite electrodes modified with AuNPs by differential pulse voltammetry (DPV). Importantly, AuNPs, which increase the electroactivity, were used to increase the surface area of a BPA-imprinted pencil graphite electrode (MIP PGE) sensor. Scanning electron microscopy and spectrophotometry analysis were used for the characterization. The DPV response of the synthesized electrode showed distinguished electrical conductivity. The MIP PGE and nonimprinted pencil graphite electrode (NIP PGE) sensor were evaluated for selective and sensitive detection of BPA in aqueous solutions. Five different BPA concentrations (1.5, 3.0, 4.5, 6.0, and 7.5 μM) were applied to the MIP PGE, and the DPV recognized signal responses with a correlation coefficient value of 0.9965. The modified electrode demonstrated good electrocatalytic activity toward BPA for the linear concentration range of 1.5-7.5 μM, and a low limit of detection was found as 0.1610 μM. The results show that the MIP PGE sensor has excellent potential for selective and sensitive detection of BPA in real water samples.
Collapse
Affiliation(s)
- Fatma Yılmaz
- Chemistry
Technology Division, Vocational School of Gerede, Bolu Abant Izzet Baysal University, Bolu 14900, Turkey
| | - Nemah Abu Shama
- Department
of Medical Research, China Medical University
Hospital, China Medical University, Taichung 404, Taiwan
| | - Süleyman Aşır
- Research
Center for Science, Technology and Engineering (BILTEM), Near East University, North Cyprus, Mersin 10, Nicosia 99138, Turkey
- Department
of Biomedical Engineering, Faculty of Engineering, Near East University, North Cyprus, Mersin 10, Nicosia 99138, Turkey
| | - Havva Çobanoğulları
- Department
of Biological Sciences, Faculty of Arts&Sciences, Eastern Mediterranean University, North Cyprus, Mersin 10, Famagusta 99628, Turkey
| | - Ercüment Yolaç
- Ataturk Faculty
of Education Nicosia, Near East University, North Cyprus, Mersin 10, Nicosia 99138, Turkey
| | - Aşkın Kiraz
- Ataturk Faculty
of Education Nicosia, Near East University, North Cyprus, Mersin 10, Nicosia 99138, Turkey
| | - Ilgım Göktürk
- Department
of Chemistry, Faculty of Science, Hacettepe
University, Beytepe, Ankara 06800, Turkey
| | - Adil Denizli
- Department
of Chemistry, Faculty of Science, Hacettepe
University, Beytepe, Ankara 06800, Turkey
| | - Deniz Türkmen
- Department
of Chemistry, Faculty of Science, Hacettepe
University, Beytepe, Ankara 06800, Turkey
| |
Collapse
|
3
|
Tang Z, Hao L, Sun D, Yang X, Su M, Zhang Y. Preparation of unique corn-stalk-like MnO₂/CoNi nanowires via in situ epitaxial attachment growth for monitoring environmental pollutant hydrazine. Talanta 2025; 282:127036. [PMID: 39406090 DOI: 10.1016/j.talanta.2024.127036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 09/19/2024] [Accepted: 10/10/2024] [Indexed: 11/20/2024]
Abstract
This paper presents the synthesis of a novel corn-stalk-like MnO₂/CoNi oxide composite using an in situ epitaxial attachment growth strategy, in which CoNi oxide nanosheets are anchored onto MnO₂ nanowires. The one-dimensional MnO₂ nanowires, with their large specific surface area, serve as a support to enhance the electronic conductivity of the CoNi oxides. Hexamethylenetetramine (HMTA) is employed as an alkaline linking agent, playing a key role in shaping the CoNi oxide nanosheets and ensuring their successful growth on the MnO₂ nanowires. The MnO₂/CoNi oxide composite-based electrochemical sensor exhibits excellent synergistic and interfacial effects, promoting electron transfer and charge migration. This composite material shows outstanding electrocatalytic performance for hydrazine detection, with a broad linear range (0.48-6106.58 μM), low detection limit (0.286 μM, S/N = 3), and high sensitivity (0.037 μA μM⁻1). Moreover, when tested for hydrazine detection in water samples, the sensor achieved a recovery rate of 95.7-105 %, highlighting its high sensitivity and rapid response in practical applications.
Collapse
Affiliation(s)
- Zhuoxian Tang
- State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, 071002, Baoding, PR China
| | - Lin Hao
- College of Science, Hebei Agricultural University, 071001, Baoding, PR China
| | - Danhua Sun
- State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, 071002, Baoding, PR China
| | - Xinjian Yang
- State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, 071002, Baoding, PR China
| | - Ming Su
- State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, 071002, Baoding, PR China; College of Life Sciences, Institute of Life Science and Green Development, Hebei University, 071002, Baoding, PR China.
| | - Yufan Zhang
- State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, 071002, Baoding, PR China; College of Life Sciences, Institute of Life Science and Green Development, Hebei University, 071002, Baoding, PR China.
| |
Collapse
|
4
|
Yarynka D, Honcharenko A, Gorbach L, Piletska E, Piletsky S, Brovko O, Sergeyeva T. Validation of a smartphone-compatible MIP-based sensor for bisphenol A determination in wastewater samples. Anal Bioanal Chem 2024; 416:7121-7129. [PMID: 39465410 DOI: 10.1007/s00216-024-05616-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 10/03/2024] [Accepted: 10/17/2024] [Indexed: 10/29/2024]
Abstract
A handheld smartphone-compatible molecularly imprinted polymer (MIP)-based sensor was developed for the analysis of bisphenol A (BPA) in wastewater samples. Sensing elements based on ethylene glycol methacrylate phosphate (EGMP)-containing MIP films were designed and optimized using molecular dynamics simulations. The highly porous MIP films were synthesized via in situ polymerization, employing a fragment-based approach. The colorimetric response was based on the 4-aminoantipyrine method, while the MIP films were further utilized to detect BPA with a smartphone. The proposed sensor exhibited a wide linear range from 5 to 250 μM, with a limit of detection (LOD) of 5 μM (S/N = 3). Furthermore, the designed analytical system demonstrated excellent analytical performance in terms of selectivity, stability, and reproducibility. During sensor validation, real wastewater samples were successfully tested for BPA, showcasing the feasibility of the smartphone-compatible MIP-based sensor. Recovery values of 87.1-114.6% underscored the efficacy and reliability of the developed sensor system.
Collapse
Affiliation(s)
- Daria Yarynka
- Institute of Molecular Biology and Genetics of the NAS of Ukraine, Zabolotnogo Str. 150, Kyiv, 03143, Ukraine.
| | - Anton Honcharenko
- Institute of Molecular Biology and Genetics of the NAS of Ukraine, Zabolotnogo Str. 150, Kyiv, 03143, Ukraine
| | - Larysa Gorbach
- Institute of Macromolecular Chemistry of the NAS of Ukraine, Kharkivske Shosse, 48, Kyiv, 02160, Ukraine
| | - Elena Piletska
- Department of Chemistry, University of Leicester, University Rd, Leicester, LE1 7RH, UK
| | - Sergey Piletsky
- Department of Chemistry, University of Leicester, University Rd, Leicester, LE1 7RH, UK
| | - Oleksandr Brovko
- Institute of Macromolecular Chemistry of the NAS of Ukraine, Kharkivske Shosse, 48, Kyiv, 02160, Ukraine
| | - Tetyana Sergeyeva
- Institute of Molecular Biology and Genetics of the NAS of Ukraine, Zabolotnogo Str. 150, Kyiv, 03143, Ukraine
| |
Collapse
|
5
|
Mayil Vealan SB, Chinnathambi S. Simultaneous determination of environmental endocrine disruptors bisphenol A and 4-nitrophenol bleached from food-contacting materials using the spin-ladder compound La 2Cu 2O 5 modified glassy carbon electrode. CHEMOSPHERE 2024; 353:141559. [PMID: 38417491 DOI: 10.1016/j.chemosphere.2024.141559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/29/2024] [Accepted: 02/24/2024] [Indexed: 03/01/2024]
Abstract
Environmental endocrine-disrupting chemicals, Bisphenol A (BPA) and 4-Nitrophenol (4-NP), pose significant risks to reproductive health in both animals and humans. Here, we introduce the first utilization of the 4-leg spin ladder compound La2Cu2O5 as an electrode material for electrochemical sensor. Nanostructured La2Cu2O5 was synthesized via a straightforward Sol-Gel method and thoroughly characterized using X-ray photoelectron spectroscopy, high-resolution transmission electron microscopy, and powder X-ray diffraction. La2Cu2O5 nanoparticles modified glassy carbon electrode (GCE) exhibited a significant electrocatalytic activity towards the oxidation of BPA and 4-NP in phosphate buffer saline (pH 7.0). Square wave voltammetry studies revealed lowest detection limits of 3 nM for BPA and 2.6 nM for 4-NP over a wider concentration range of 0.01-500 μM. Notably, this study marks the first utilization of La2Cu2O5 for simultaneous electrochemical detection of BPA and 4-NP, demonstrating its potential in this field. Furthermore, the sensor exhibited good sensitivity, reproducibility, and selectivity towards BPA and 4-NP, even in the presence of similar potential organic and inorganic interferents. Additionally, the newly developed sensor enabled simultaneous quantification of BPA and 4-NP in real samples such as packaged milk, river water, and plastic bottles, achieving recovery rates above 95%. Importantly, our results underscore the leaching of BPA into water from thin and thick plastics at elevated temperatures (40 °C-80 °C), emphasizing the utility of the proposed sensor for rapid and simultaneous detection of BPA and 4-NP in environmental and food matrices.
Collapse
Affiliation(s)
- S B Mayil Vealan
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi-630003, Tamil Nadu, India
| | - Sekar Chinnathambi
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi-630003, Tamil Nadu, India.
| |
Collapse
|
6
|
Zhao Y, Zhang S, Yao W, Zhu Y, Qian J, Yang J, Yang N. Design and synthesis of hierarchical MnO-Fe 3O 4@C/expanded graphite composite for sensitive electrochemical detection of bisphenol A. Talanta 2024; 269:125453. [PMID: 38006729 DOI: 10.1016/j.talanta.2023.125453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 08/30/2023] [Accepted: 11/20/2023] [Indexed: 11/27/2023]
Abstract
Hierarchically nanostructured binary transition metal oxide-based materials with high conductivity and catalytic activity are quite attractive for the electrochemical quantitative detection of environmental pollutants due to their natural abundance, variable oxidation state, and excellent synergies between metal sites. Herein, a new hierarchical MnO-Fe3O4@C/expanded graphite (EG) composite is designed and synthesized through a simple and in situ annealing method with the utilization of bimetallic organic framework (FeMn-MOF)/EG precursor. The synthesized MnO-Fe3O4@C/EG composite possesses a unique hierarchical nanoarchitecture that small-sized bimetallic oxide nanoparticles of 10-40 nm completely encapsulated by amorphous carbon layers of 2-4 nm are uniformly distributed on the EG platform. This distinctive structure combines the advantages of high conductivity, excellent catalytic activity, and strong stability. Resultantly, when it is applied to monitor environmental endocrine disruptors, the sensor exhibits a significant catalytic effect on the electrochemical oxidation of bisphenol A (BPA), inducing an amplified response current. In addition, the sensor shows a wide linear range of 1-50 μM and 50-400 μM for the BPA monitor, giving a sensitivity of 5208.8 and 1641.9 μA mM-1 cm-2, respectively. This study offers a new approach to design hierarchical binary metal oxide-based sensing materials as well as to explore their electrochemical properties and applications for the determination of emerging contaminants.
Collapse
Affiliation(s)
- Yao Zhao
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China
| | - Shu Zhang
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China
| | - Wang Yao
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China
| | - Yuxuan Zhu
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China
| | - Jing Qian
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China
| | - Juan Yang
- School of Chemistry and Environmental Engineering, Key Laboratory for Green Chemical Process of Ministry of Education, Hubei Key Lab of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430073, China.
| | - Nianjun Yang
- Department of Chemistry, Hasselt University, 3590, Diepenbeek, Belgium; IMO-IMOMEC, Hasselt University, 3590, Diepenbeek, Belgium
| |
Collapse
|
7
|
Koo KM, Kim CD, Kim TH. Recent Advances in Electrochemical Detection of Cell Energy Metabolism. BIOSENSORS 2024; 14:46. [PMID: 38248422 PMCID: PMC10813075 DOI: 10.3390/bios14010046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/12/2024] [Accepted: 01/12/2024] [Indexed: 01/23/2024]
Abstract
Cell energy metabolism is a complex and multifaceted process by which some of the most important nutrients, particularly glucose and other sugars, are transformed into energy. This complexity is a result of dynamic interactions between multiple components, including ions, metabolic intermediates, and products that arise from biochemical reactions, such as glycolysis and mitochondrial oxidative phosphorylation (OXPHOS), the two main metabolic pathways that provide adenosine triphosphate (ATP), the main source of chemical energy driving various physiological activities. Impaired cell energy metabolism and perturbations or dysfunctions in associated metabolites are frequently implicated in numerous diseases, such as diabetes, cancer, and neurodegenerative and cardiovascular disorders. As a result, altered metabolites hold value as potential disease biomarkers. Electrochemical biosensors are attractive devices for the early diagnosis of many diseases and disorders based on biomarkers due to their advantages of efficiency, simplicity, low cost, high sensitivity, and high selectivity in the detection of anomalies in cellular energy metabolism, including key metabolites involved in glycolysis and mitochondrial processes, such as glucose, lactate, nicotinamide adenine dinucleotide (NADH), reactive oxygen species (ROS), glutamate, and ATP, both in vivo and in vitro. This paper offers a detailed examination of electrochemical biosensors for the detection of glycolytic and mitochondrial metabolites, along with their many applications in cell chips and wearable sensors.
Collapse
Affiliation(s)
| | | | - Tae-Hyung Kim
- School of Integrative Engineering, Chung-Ang University, 84 Heukseuk-ro, Dongjak-gu, Seoul 06974, Republic of Korea; (K.-M.K.); (C.-D.K.)
| |
Collapse
|
8
|
Fang Z, Wang J, Xue Y, Khorasani Motlagh M, Noroozifar M, Kraatz HB. Palladium-Copper Bimetallic Aerogel as New Modifier for Highly Sensitive Determination of Bisphenol A in Real Samples. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6081. [PMID: 37763359 PMCID: PMC10533138 DOI: 10.3390/ma16186081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 08/30/2023] [Accepted: 08/31/2023] [Indexed: 09/29/2023]
Abstract
In this study, a bimetallic palladium-copper aerogel was synthesized and used for modification of a graphite paste electrode (Pd-Cu/GPE), allowing the sensitive determination of bisphenol A (BPA). Different techniques, such as SEM, TEM, XPS, and AFM, were used for characterization of the Pd-Cu aerogel. To elucidate the properties of the Pd-Cu/GPE, the electrochemistry methods such as differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy were used. DPV measurements were conducted in phosphate electrolyte and buffer solution (0.2 M PBS, pH 5) at a potential range from 0.4 to 0.9 V vs. Ag/AgCl. The DPVs peaks currents increased linearly with BPA concentrations in the 0.04-85 and 85-305 µM ranges, with a limit of detection of 20 nM. The modified electrode was successfully used in real samples to determine BPA, and the results were compared to the standard HPLC method. The results showed that the Pd-Cu/GPE had good selectivity, stability, and sensitivity for BPA determination.
Collapse
Affiliation(s)
- Zehao Fang
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
| | - Junyan Wang
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
| | - Yilei Xue
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
- Department of Chemistry, University of Toronto, 280 St. George Street, Toronto, ON M5S 3H6, Canada
| | - Mozhgan Khorasani Motlagh
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
| | - Meissam Noroozifar
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
| | - Heinz-Bernhard Kraatz
- Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada; (Z.F.); (J.W.); (Y.X.)
- Department of Chemistry, University of Toronto, 280 St. George Street, Toronto, ON M5S 3H6, Canada
| |
Collapse
|
9
|
A V M, K A, I BM. An integrated approach to remove endocrine-disrupting chemicals bisphenol and its analogues from the aqueous environment: a review. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2023; 88:1518-1546. [PMID: 37768753 PMCID: wst_2023_280 DOI: 10.2166/wst.2023.280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Bisphenol A (BPA) is a well-known endocrine-disrupting chemical (EDC) used as a plastic enhancer in producing polycarbonate resins to manufacture hard plastics. Due to strict limitations on the manufacturing and utilization of BPA, several bisphenol substitutes, bisphenol F (BPF), bisphenol S (BPS), and bisphenol AF (BPAF), have been developed to replace it in various applications. Because of their widespread use in food containers, infant bottles, and reusable water bottles, bisphenols (BPs) have been identified in different environmental circumstances, including drinking water, seawater, industrial effluent, and endocrine systems such as human blood, urine, and breast milk. However, locating and analyzing them in different conditions has proven to be challenging. Therefore, there is a need to reduce the prevalence of BPs in the environment. The significance of advanced treatment options for treating and eliminating BPA and its alternatives from water bodies are reviewed. Also, the research gaps and future scopes are discussed in this review article. According to the literature survey, adsorption and photocatalytic degradation provide synergistic benefits for environmental challenges because of their substantial adsorption Q5 capacity, high oxidation capability, and low cost compared to alternative individual treatment options.
Collapse
Affiliation(s)
- Monica A V
- Department of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603 203, India E-mail:
| | - Anbalagan K
- Department of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603 203, India
| | - Becky Miriyam I
- Department of Chemical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603 203, India
| |
Collapse
|
10
|
Bao Q, Li G, Yang Z, Wei J, Cheng W, Qu Z, Lin L. A Time-Division Multiplexing Multi-Channel Micro-Electrochemical Workstation with Carbon-Based Material Electrodes for Online L-Trosine Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:6252. [PMID: 37514547 PMCID: PMC10386381 DOI: 10.3390/s23146252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/02/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
In the background of the rapid development of artificial intelligence, big data, IoT, 5G/6G, and other technologies, electrochemical sensors pose higher requirements for high-throughput detection. In this study, we developed a workstation with up to 10 channels, which supports both parallel signal stimulation and online electrochemical analysis functions. The platform was wired to a highly integrated Bluetooth chip used for wireless data transmission and can be visualized on a smartphone. We used this electrochemical test platform with carbon-graphene oxide/screen-printed carbon electrodes (CB-GO/SPCE) for the online analysis of L-tyrosine (Tyr), and the electrochemical performance and stability of the electrodes were examined by differential pulse voltammetry (DPV). The CB-GO-based screen-printed array electrodes with a multichannel electrochemical platform for Tyr detection showed a low detection limit (20 μM), good interference immunity, and 10-day stability in the range of 20-200 μM. This convenient electrochemical analytical device enables high-throughput detection and has good economic benefits that can contribute to the improvement of the accuracy of electrochemical analysis and the popularization of electrochemical detection methods in a wide range of fields.
Collapse
Affiliation(s)
- Qiwen Bao
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Gang Li
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhengchun Yang
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Jun Wei
- School of Materials Science and Engineering, Harbin Institute of Technology, Shenzhen 518055, China
| | - Wenbo Cheng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zilian Qu
- Beijing Information Technol Coll, Beijing 100015, China
| | - Ling Lin
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| |
Collapse
|
11
|
Vidal JC, Midón J, Vidal AB, Ciomaga D, Laborda F. Detection, quantification, and characterization of polystyrene microplastics and adsorbed bisphenol A contaminant using electroanalytical techniques. Mikrochim Acta 2023; 190:203. [PMID: 37156867 PMCID: PMC10167125 DOI: 10.1007/s00604-023-05780-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Accepted: 04/04/2023] [Indexed: 05/10/2023]
Abstract
The potential applications of electroanalytical techniques for the quantification and size characterization of nonelectroactive polystyrene microplastics is reported, in addition to characterizing the kinetics of adsorption of bisphenol A on these polystyrene microparticles. The individual adsorption events of very diluted polystyrene microparticles dispersions on glassy-carbon microelectrodes produce the blocking of the charge transfer of a mediator (ferrocene-methanol) thus decreasing the current of the recorded chronoamperogram in a stepwise manner. The magnitude of the current steps are in the order of pA values and can be related to the diameter of the plastic microparticles in the size range 0.1 to 10 µm. The frequency of the current steps in the domain time used (120 s) allows to quantify the number concentration of these microparticles in the range 0.005 to 0.500 pM. Electrochemical impedance spectroscopy confirms the adsorption of the polystyrene microplastics on carbon microelectrodes (and to a lesser extent on platinum microelectrodes) under the same experimental conditions as above. On the other hand, the adsorbed microplastics become concentrators of other pollutants found in the environment. The sensitive differential-pulse voltammetry determination of bisphenol A (linear range 0.80-15.00 µM; detection limit 0.24 µM) was used together with a simple separation procedure for studying the adsorption of bisphenol A on polystyrene microparticles. The adsorption capacity (mg of bisphenol A retained per g of the polystyrene microplastics) decreased from approximately 5.7 to 0.8 mg g-1 with increasing dosages of polystyrene microparticles from 0.2 to 1.6 g l-1. The adsorption isotherms were modeled resulting in a monolayer of bisphenol A adsorbed on the microplastics (i.e., best fitted to a Langmuir model).
Collapse
Affiliation(s)
- Juan C Vidal
- Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain.
| | - Javier Midón
- Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain
| | - Ana B Vidal
- Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain
| | - Dragos Ciomaga
- Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain
| | - Francisco Laborda
- Group of Analytical Spectroscopy and Sensors (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain
| |
Collapse
|
12
|
Song D, Xu W, Yang R, Han X, Zhuo Y, Liu J, Long F. Universal and rapid detection of atrazine and bisphenol A using a reusable optical fiber chemiluminescent biosensor. Talanta 2023; 255:124252. [PMID: 36630785 DOI: 10.1016/j.talanta.2023.124252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 01/09/2023]
Abstract
Timely and accurately detection of small molecule pollutants is quite necessary to control environmental pollution and reduce harmfulness. Herein, a reusable optical fiber chemiluminescent biosensor (ROFC) was proposed for universal and rapid detection of two representative pollutants, pesticide atrazine (ATZ) and endocrine disruptor bisphenol A (BPA). The optical fiber modified with hapten-protein conjugates was regarded as both bio-probe and chemiluminescence signal transmission element, which effectively improved the light transmission efficiency and signal-to-noise ratio of the system. High-sensitive chemiluminescence signal detection is realized with a miniaturized ultrasensitive photodiode detector. Good regeneration performance of bio-probe can reduce detection cost and ensure detection reproducibility. Based on indirect competitive immunoassay principle, the chemiluminescence signal decreased with increasing pollutant concentration resulting from the less amount of antibody combined on the bio-probe surface. Under optimal conditions, the whole assay was achieved within 25 min with linear range of 1-100 μg/L and detection limits (LOD) for atrazine and BPA are 0.029 μg/L and 0.025 μg/L, respectively. The immunosensing optical fiber probe can be reused for 150 times at least without losing obvious bioactivity. The method was successfully applied to the detection of ATZ and BPA in three environmental samples, where recoveries between 93.4% and 116.6% were achieved. The ROFC biosensor provides a feasible platform for rapid detection of multiple small molecule pollutants in the environment.
Collapse
Affiliation(s)
- Dan Song
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Wenjuan Xu
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Rong Yang
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Xiangzhi Han
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Yuxin Zhuo
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Jiayuan Liu
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China
| | - Feng Long
- School of Environment and Natural Resources, Renmin University of China, Beijing, 100872, China.
| |
Collapse
|
13
|
Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A. Anal Biochem 2023; 662:115002. [PMID: 36473678 DOI: 10.1016/j.ab.2022.115002] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 11/25/2022] [Accepted: 11/30/2022] [Indexed: 12/07/2022]
Abstract
Electrochemical (bio)sensors were developed for bisphenol A (BPA) determination. Screen printed carbon electrode (SPCE) was modified with ionic liquid 1- butyl-3-methylimidazolium tetrafluoroborate (IL), carbon quantum dots (CQD) and gold nanoparticles (AuNP) for the fabrication of the BPA sensor. Electrode surface composition was optimized for the deposition time of AuNP, amount of CQD and percentage of IL using the central composite design (CCD) method. The results of the CCD study indicated that maximum amperometric response was recorded when 9.8 μg CQD, 3% IL and 284 s AuNP deposition time were used in modification. Tyrosinase (Ty) was further modified on the AuNP/CQD-IL/SPCE to fabricate the biosensor. Analytical performance characteristics of the BPA sensor were investigated by differential pulse anodic adsorptive stripping voltammetry and the AuNP/CQD-IL/SPCE sensor exhibited a linear response to BPA in the range of 2.0 × 10-8 - 3.6 × 10-6 M with a detection limit of 1.1 × 10-8 M. Amperometric measurements showed that the linear dynamic range and detection limit of the Ty/AuNP/CQD-IL/SPCE were 2.0 × 10-8 - 4.0 × 10-6 M and 6.2 × 10-9 M, respectively. Analytical performance characteristics such as sensitivity, reproducibility and selectivity were investigated for the presented (bio)sensors. The analytical applicability of the (bio)sensors to the analysis of BPA in mineral water samples was also tested.
Collapse
|
14
|
Teradale AB, Chadchan KS, Ganesh PS, Das SN, Ebenso EE. Synergetic effects of a poly-tartrazine/CTAB modified carbon paste electrode sensor towards simultaneous and interference-free determination of benzenediol isomers. REACT CHEM ENG 2023; 8:3071-3081. [DOI: 10.1039/d3re00318c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/23/2024]
Abstract
Simultaneous and selective detection of dihydroxy benzene isomers by the synergistic effect of CTAB and tartrazine on a carbon paste electrode (poly-TZ/CTAB/MCPE) sensor by CV and DPV techniques.
Collapse
Affiliation(s)
- Amit B. Teradale
- PG Department of Chemistry, BLDEA's S.B. Arts and K.C.P. Science College, Vijayapur, Karnataka, 586103, India
| | - Kailash S. Chadchan
- Department of Chemistry, BLDEA's V. P. Dr. P. G. Halakatti College of Engineering and Technology, Vijayapur-586103, Karnataka, India
| | - Pattan-Siddappa Ganesh
- Advanced Technology Research Center, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 31253, Republic of Korea
| | - Swastika N. Das
- Department of Chemistry, BLDEA's V. P. Dr. P. G. Halakatti College of Engineering and Technology, Vijayapur-586103, Karnataka, India
| | - Eno E. Ebenso
- Centre for Material Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1710, South Africa
- Institute of Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1710, South Africa
| |
Collapse
|
15
|
Chemo/biosensors towards effect-directed analysis: An overview of current status and future development. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Chen J, Huang X, Ye R, Huang D, Wang Y, Chen S. Fabrication of a novel electrochemical sensor using conductive MOF Cu-CAT anchored on reduced graphene oxide for BPA detection. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01735-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
17
|
Kolhe P, Roberts A, Gandhi S. Fabrication of an ultrasensitive electrochemical immunosensor coupled with biofunctionalized zero-dimensional graphene quantum dots for rapid detection of cephalexin. Food Chem 2022; 398:133846. [DOI: 10.1016/j.foodchem.2022.133846] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 07/05/2022] [Accepted: 07/31/2022] [Indexed: 12/18/2022]
|
18
|
Chen Z, Wei W, Liu X, Ni BJ. Emerging electrochemical techniques for identifying and removing micro/nanoplastics in urban waters. WATER RESEARCH 2022; 221:118846. [PMID: 35841793 DOI: 10.1016/j.watres.2022.118846] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/07/2022] [Accepted: 07/09/2022] [Indexed: 05/26/2023]
Abstract
The ubiquitous micro/nanoplastics (MPs/NPs) in urban waters are priority pollutants due to their toxic effects on living organisms. Currently, great efforts have been made to realize a plastic-free urban water system, and the identification and removal of MPs/NPs are two primary issues. Among diverse methods, emerging electrochemical techniques have gained growing interests owing to their facile implementation, high efficiency, eco-compatibility, onsite operation, etc. Herein, recent progress in the electrochemical identification and removal of MPs/NPs in urban waters are comprehensively reviewed. The electrochemical sensing of MPs/NPs and their released pollutants (e.g., bisphenol A (BPA)) has been analyzed, and the sensing principles and the featured electrochemical devices/electrodes are examined. Afterwards, recent applications of electrochemical methods (i.e., electrocoagulation, electroadsorption, electrokinetic separation and electrochemical degradation) in MPs/NPs removal are discussed in detail. The influences of critical parameters (e.g., plastics' property, current density and electrolyte) in the electrochemical identification and removal of MPs/NPs are also analyzed. Finally, the current challenges and prospects in electrochemical sensing and removal of MPs/NPs in urban waters are elaborated. This review would advance efficient electrochemical technologies for future MPs/NPs pollutions management in urban waters.
Collapse
Affiliation(s)
- Zhijie Chen
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, NSW 2007, Australia
| | - Wei Wei
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, NSW 2007, Australia
| | - Xiaoqing Liu
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, NSW 2007, Australia
| | - Bing-Jie Ni
- Centre for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, NSW 2007, Australia.
| |
Collapse
|
19
|
Recent Advances of Nanomaterials-Based Molecularly Imprinted Electrochemical Sensors. NANOMATERIALS 2022; 12:nano12111913. [PMID: 35683768 PMCID: PMC9182195 DOI: 10.3390/nano12111913] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/27/2022] [Accepted: 05/30/2022] [Indexed: 02/06/2023]
Abstract
Molecularly imprinted polymer (MIP) is illustrated as an analogue of a natural biological antibody-antigen system. MIP is an appropriate substrate for electrochemical sensors owing to its binding sites, which match the functional groups and spatial structure of the target analytes. However, the irregular shapes and slow electron transfer rate of MIP limit the sensitivity and conductivity of electrochemical sensors. Nanomaterials, famous for their prominent electron transfer capacity and specific surface area, are increasingly employed in modifications of MIP sensors. Staying ahead of traditional electrochemical sensors, nanomaterials-based MIP sensors represent excellent sensing and recognition capability. This review intends to illustrate their advances over the past five years. Current limitations and development prospects are also discussed.
Collapse
|
20
|
Ye RH, Chen JY, Huang DH, Wang YJ, Chen S. Electrochemical Sensor Based on Glassy-Carbon Electrode Modified with Dual-Ligand EC-MOFs Supported on rGO for BPA. BIOSENSORS 2022; 12:bios12060367. [PMID: 35735515 PMCID: PMC9221176 DOI: 10.3390/bios12060367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/08/2022] [Accepted: 05/20/2022] [Indexed: 11/16/2022]
Abstract
The electronic conductive metal-organic frameworks (EC-MOFs) based on a single ligand are not suitable for the accurate detection of bisphenol A (BPA) due to the limitations of their electron-transfer-based sensing mechanism. To overcome this drawback, we developed EC-MOFs with novel dual-ligands, 2,3,6,7,10,11-hexahydroxy-sanya-phenyl (HHTP) and tetrahydroxy 1,4-quinone (THQ), and metal ions. A new class of 2D π-conjugation-based EC-MOFs (M-(HHTP)(THQ)) was synthesized by a self-assemble technique. Its best member (Cu-(HHTP)(THQ)) was selected and combined with reduced graphene (rGO) to form a Cu-(HHTP)(THQ)@rGO composite, which was thoroughly characterized by X-ray diffraction, field scanning electron microscopy, and energy-dispersive X-ray spectroscopy. Cu-(HHTP)(THQ)@rGO was drop-cast onto a glassy carbon electrode (GCE) to obtain a sensor for BPA detection. Cyclic voltammetry and electrochemical impedance tests were used to evaluate the electrode performance. The oxidation current of BPA on the Cu-(HHTP)(THQ)@rGO/GCE was substantially higher than on unmodified GCE, which could be explained by a synergy between Cu-(HHTP)(THQ) (which provided sensing and adsorption) and rGO (which provided fast electron conductivity and high surface area). Cu-(HHTP)(THQ)@rGO/GCE exhibited a linear detection range for 0.05–100 μmol·L−1 of BPA with 3.6 nmol·L−1 (S/N = 3) detection limit. We believe that our novel electrode and BPA sensing method extends the application perspectives of EC-MOFs in the electrocatalysis and sensing fields.
Collapse
Affiliation(s)
- Rui-Hong Ye
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| | - Jin-Yang Chen
- College of Life Sciences, Fujian Normal University, Fuzhou 350117, China;
| | - Di-Hui Huang
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
- Correspondence:
| | - Yan-Jun Wang
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| | - Sheng Chen
- Fujian Province-Indonesia Marine Food Joint Research and Development Center, Fujian Polytechnic Normal University, Fuqing 350300, China; (R.-H.Y.); (Y.-J.W.); (S.C.)
| |
Collapse
|
21
|
Hu C, Huang H, Yan Y, Hu Y, Liu SJ, Wen HR. Simple Synthesis of CeO2 Nanoparticle Composites In Situ Grown on Carbon Nanotubes for Phenol Detection. Front Chem 2022; 10:907777. [PMID: 35655701 PMCID: PMC9152013 DOI: 10.3389/fchem.2022.907777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 04/27/2022] [Indexed: 11/13/2022] Open
Abstract
via simple hydrothermal method, CeO2 was in-situ grown onto the CNTs to form CeO2/CNTs nanocomposites were synthesized with cerium nitrate as Ce resource. The morphology and structure were characterized by transmission electron microscopy and X-ray diffraction. The characterizations reveal that CeO2 nanoparticles are uniformly dispersed onto the surface of the pre-acidified CNTs. The electrochemical property of the synthesized nanocomposite was investigated in 0.1 M KCl electrolyte containing 2 mM [Fe(CN)6]3-/4-. The nanocomposites were employed to fabricate electrochemical sensor for phenol detection. The linear range for phenol detection measured by the differential pulse voltammetry method is 1–500 μM. The sensor also exhibits good selectivity, reproducibility and stability. When applied for the river and tap water analysis, it shows good recovery rate.
Collapse
Affiliation(s)
- Chao Hu
- Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, China
| | - Haiping Huang
- Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, China
- Key Laboratory of Testing and Tracing of Rare Earth Products for State Market Regulation, Jiangxi University of Science and Technology, Ganzhou, China
- *Correspondence: Haiping Huang,
| | - Yu Yan
- Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, China
| | - Yongmei Hu
- Key Laboratory of Testing and Tracing of Rare Earth Products for State Market Regulation, Jiangxi University of Science and Technology, Ganzhou, China
| | - Sui-Jun Liu
- Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, China
| | - He-Rui Wen
- Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, China
| |
Collapse
|
22
|
Sivaranjanee R, Senthil Kumar P, Saravanan R, Govarthanan M. Electrochemical sensing system for the analysis of emerging contaminants in aquatic environment: A review. CHEMOSPHERE 2022; 294:133779. [PMID: 35114262 DOI: 10.1016/j.chemosphere.2022.133779] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 01/19/2022] [Accepted: 01/26/2022] [Indexed: 06/14/2023]
Abstract
This survey distinguishes understudied spaces of arising impurity research in wastewaters and the habitat, and suggests bearing for future checking. Thinking about the impeding effect of toxins on human wellbeing and biological system, their discovery in various media including water is fundamental. This review sums up and assesses the latest advances in the electrochemical detecting of emerging contaminants (ECs). This survey is expected to add to the advancement in electrochemical applications towards the ECs. Different electrochemical insightful procedures like Amperometry, Voltammetry has been examined in this overview. The improvement of cutting edge nanomaterial-based electrochemical sensors and biosensors for the discovery of drug compounds has accumulated monstrous consideration because of their benefits, like high affectability and selectivity, continuous observing, and convenience has been reviewed in this survey. This survey likewise features the diverse electrochemical treatment procedures accessible for the removal of ECs.
Collapse
Affiliation(s)
- R Sivaranjanee
- Department of Chemical Engineering, St. Joseph's College of Engineering, Chennai, 600119, India
| | - P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, 603110, India; Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Chennai, 603110, India.
| | - R Saravanan
- Department of Mechanical Engineering, Universidad de Tarapacá, Arica, Chile
| | - M Govarthanan
- Department of Environmental Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| |
Collapse
|
23
|
Portable electrochemical sensing methodologies for on-site detection of pesticide residues in fruits and vegetables. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2021.214305] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
24
|
Chen J, Wang J, Ye R, Huang D, Chen S. An electrochemical sensor based on a glassy carbon electrode modified with sandwich structured ZIF-67@rGO for bisphenol A measurement. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5777-5786. [PMID: 34825246 DOI: 10.1039/d1ay01542g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The low conductivity of metal-organic frameworks seriously impedes their electrocatalytic performance. In this study, we prepared a fabricated sandwich structure composed of a Co-based zeolitic imidazolate framework (ZIF-67) and reduced graphene oxide (rGO) through a facile and simple one-pot hydrothermal reaction. This framework of nanocomposites, which are modified with a glassy carbon electrode, constructed a bisphenol A (BPA) electrochemical sensor for the first time. Operational parameters such as pH, electrolytes, the amount of modifiers, deposition potentials and deposition time were optimised for the sensitive detection of BPA. The performance of electrodes was evaluated by cyclic voltammetry, electrochemical impedance spectroscopy, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction and transmission electron microscopy. With differential pulse voltammetry, the detection concentration of BPA ranged from 0.05 μmol L-1 to 100 μmol L-1. The results revealed that the hierarchical nanocomposites demonstrated better electrocatalytic performance with large electrochemically active surface areas, high sensitivity and a low limit of detection (5.2 nmol L-1), compared with a physical mixture of ZIF-67 and rGO at the same ratio. These impressive features originate from the synergistic effects of ZIF-67 and rGO. This study presents a new strategy using metal-organic framework composite materials for the sensitive detection of BPA.
Collapse
Affiliation(s)
- Jinyang Chen
- Fujian Polytechnic Normal University, Food Flexible Packaging Technology Fujian University Engineering Research Center, Fuqing, Fujian 350300, China.
- Fujian Normal University, Collge of Life sciences, Fuzhou 350117, Fujian, China
| | - Jiamei Wang
- Fujian Polytechnic Normal University, Food Flexible Packaging Technology Fujian University Engineering Research Center, Fuqing, Fujian 350300, China.
| | - Ruihong Ye
- Fujian Polytechnic Normal University, Food Flexible Packaging Technology Fujian University Engineering Research Center, Fuqing, Fujian 350300, China.
| | - Dihui Huang
- Fujian Polytechnic Normal University, Food Flexible Packaging Technology Fujian University Engineering Research Center, Fuqing, Fujian 350300, China.
| | - Sheng Chen
- Fujian Polytechnic Normal University, Food Flexible Packaging Technology Fujian University Engineering Research Center, Fuqing, Fujian 350300, China.
| |
Collapse
|
25
|
A comparison study of MFe2O4 (M: Ni, Cu, Zn)-reduced graphene oxide nanocomposite for electrochemical detection of bisphenol A. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138519] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
26
|
Tsekeli TR, Tshwenya L, Sebokolodi TI, Ndlovu T, Arotiba OA. An Electrochemical Aptamer Biosensor for Bisphenol A on a Carbon Nanofibre‐silver Nanoparticle Immobilisation Platform. ELECTROANAL 2021. [DOI: 10.1002/elan.202100167] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Tebogo R. Tsekeli
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 South Africa
| | - Luthando Tshwenya
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 South Africa
| | | | - Thabile Ndlovu
- Department of Chemistry University of Eswatini Kwaluseni M201 Eswatini
| | - Omotayo A. Arotiba
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 South Africa
- Centre for Nanomaterials Science Research University of Johannesburg Johannesburg 2028 South Africa
| |
Collapse
|
27
|
Lu F, Lin J, Lin C, Qi G, Lin X, Xie Z. Heteroporous 3D covalent organic framework-based magnetic nanospheres for sensitive detection of bisphenol A. Talanta 2021; 231:122343. [PMID: 33965019 DOI: 10.1016/j.talanta.2021.122343] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 03/07/2021] [Accepted: 03/18/2021] [Indexed: 11/25/2022]
Abstract
Covalent organic frameworks (COFs) showed great promise in effective adsorption of target molecule via size selectivity. Although various magnetic 2D COFs composites have been studied and exhibited the intensive applications, the incorporation of 3D COFs and magnetic nanoparticles to form a new class of magnetic adsorbents with enhanced function still has no reports. Herein, a novel Fe3O4@3D COF with heteroporous structure matching to the sizes of bisphenol A (BPA) was firstly synthesized for better adsorption of BPA than common magnetic 2D-COFs. Three Fe3O4@3D COFs nanospheres were synthesized under the solvothermal conditions in autoclave, and the optimum Fe3O4@3D-COF denoted as Fe3O4@COF-TpTAM (Tp, 1,3,5-triformylphloroglucinol; TAM, tetra(p-aminophenyl)-methane) was selected and employed. Detailed characteristics of Fe3O4@COF-TpTAM were evaluated via various techniques including TEM, FTIR, TGA, XRD and BET. Excellent chemical and thermal stability, high surface area (294.6 m2 g-1) and pore volume (0.2 m3 g-1) with multiple pore sizes comparable with the simulated three-dimensional sizes of BPA were exhibited. A high adsorption capacity of BPA up to 209.9 mg/g that was better than common 2D-COFs was achieved, and the sensitive MSPE-LC-MS method with wide linear range (10-5000 pg/mL), low detection limit (4 pg/mL, S/N = 3) was built. Satisfactory recoveries of BPA as 93.8 ± 1.4%-101.4 ± 5.1% (n = 3) and 100.4 ± 1.9% ~ 107.3 ± 1.2% (n = 3) were obtained in milk and river water samples, respectively. This work demonstrates the promising application of Fe3O4@3D COF as efficient adsorbents of trace BPA, and opens up a new access for the efficient MSPE in sample pretreatment for food or environmental safety analysis.
Collapse
Affiliation(s)
- Feifei Lu
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Jian Lin
- Forensic Science Division, Fujian Provincial Department of Public Security, Fuzhou, China
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Guomin Qi
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| |
Collapse
|
28
|
Raja IS, Vedhanayagam M, Preeth DR, Kim C, Lee JH, Han DW. Development of Two-Dimensional Nanomaterials Based Electrochemical Biosensors on Enhancing the Analysis of Food Toxicants. Int J Mol Sci 2021; 22:3277. [PMID: 33806998 PMCID: PMC8005143 DOI: 10.3390/ijms22063277] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 03/19/2021] [Accepted: 03/21/2021] [Indexed: 12/25/2022] Open
Abstract
In recent times, food safety has become a topic of debate as the foodborne diseases triggered by chemical and biological contaminants affect human health and the food industry's profits. Though conventional analytical instrumentation-based food sensors are available, the consumers did not appreciate them because of the drawbacks of complexity, greater number of analysis steps, expensive enzymes, and lack of portability. Hence, designing easy-to-use tests for the rapid analysis of food contaminants has become essential in the food industry. Under this context, electrochemical biosensors have received attention among researchers as they bear the advantages of operational simplicity, portability, stability, easy miniaturization, and low cost. Two-dimensional (2D) nanomaterials have a larger surface area to volume compared to other dimensional nanomaterials. Hence, researchers nowadays are inclined to develop 2D nanomaterials-based electrochemical biosensors to significantly improve the sensor's sensitivity, selectivity, and reproducibility while measuring the food toxicants. In the present review, we compile the contribution of 2D nanomaterials in electrochemical biosensors to test the food toxicants and discuss the future directions in the field. Further, we describe the types of food toxicity, methodologies quantifying food analytes, how the electrochemical food sensor works, and the general biomedical properties of 2D nanomaterials.
Collapse
Affiliation(s)
| | | | - Desingh Raj Preeth
- Chemical Biology and Nanobiotechnology Laboratory, AU-KBC Research Centre, Anna University, MIT Campus, Chromepet, Chennai 600 044, India;
| | - Chuntae Kim
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea; (I.S.R.); (C.K.)
| | - Jong Hun Lee
- Department of Food Science and Biotechnology, Gachon University, Seongnam 13120, Korea
| | - Dong Wook Han
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea; (I.S.R.); (C.K.)
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan 46241, Korea
| |
Collapse
|
29
|
Arul P, Huang ST, Gowthaman NSK, Mani G, Jeromiyas N, Shankar S, John SA. Electrocatalyst based on Ni-MOF intercalated with amino acid-functionalized graphene nanoplatelets for the determination of endocrine disruptor bisphenol A. Anal Chim Acta 2021; 1150:338228. [PMID: 33583553 DOI: 10.1016/j.aca.2021.338228] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 01/13/2021] [Accepted: 01/13/2021] [Indexed: 12/20/2022]
Affiliation(s)
- P Arul
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan
| | - Sheng-Tung Huang
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan.
| | - N S K Gowthaman
- Centre for Nanoscience and Nanotechnology, Department of Chemistry, The Gandhigram Rural Institute, Gandhigram, 624 302, Dindigul, Tamilnadu, India
| | - G Mani
- Department of Materials Science and Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, ROC
| | - Nithiya Jeromiyas
- Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan
| | - Sekar Shankar
- School of Material Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, PR China
| | - S Abraham John
- Centre for Nanoscience and Nanotechnology, Department of Chemistry, The Gandhigram Rural Institute, Gandhigram, 624 302, Dindigul, Tamilnadu, India
| |
Collapse
|
30
|
Zhang F, Huang F, Gong W, Tian F, Wu H, Ding S, Li S, Luo R. Multi-branched PdPt nanodendrites decorated amino-rich Fe-based metal-organic framework as signal amplifier for ultrasensitive electrochemical detection of prolactin. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
31
|
Tajik S, Dourandish Z, Jahani PM, Sheikhshoaie I, Beitollahi H, Shahedi Asl M, Jang HW, Shokouhimehr M. Recent developments in voltammetric and amperometric sensors for cysteine detection. RSC Adv 2021; 11:5411-5425. [PMID: 35423079 PMCID: PMC8694840 DOI: 10.1039/d0ra07614g] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Accepted: 12/06/2020] [Indexed: 12/27/2022] Open
Abstract
This review article aims to provide an overview of the recent advances in the voltammetric and amperometric sensing of cysteine (Cys). The introduction summarizes the important role of Cys as an essential amino acid, techniques for its sensing, and the utilization of electrochemical methods and chemically modified electrodes for its determination. The main section covers voltammetric and amperometric sensing of Cys based on glassy carbon electrodes, screen printed electrodes, and carbon paste electrodes, modified with various electrocatalytic materials. The conclusion section discusses the current challenges of Cys determination and the future perspectives.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences Kerman Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | | | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
| | - Mehdi Shahedi Asl
- Marine Additive Manufacturing Centre of Excellence (MAMCE), University of New Brunswick Fredericton NB E3B 5A1 Canada
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| |
Collapse
|
32
|
Electrochemical Detection of Bisphenol A by Tyrosinase Immobilized on Electrospun Nanofibers Decorated with Gold Nanoparticles. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2010004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Bisphenol A (BPA) is an endocrine-disrupting chemical (EDC) employed in industrial processes that causes adverse effects on the environment and human health. Sensitive and inexpensive methods to detect BPA are therefore needed. In this paper, we describe an electrochemical biosensor for detecting low levels of BPA using polymeric electrospun nanofibers of polyamide 6 (PA6) and poly(allylamine hydrochloride) (PAH) decorated with gold nanoparticles (AuNPs), namely, PA6/PAH@AuNPs, which were deposited onto a fluorine-doped tin oxide (FTO) substrate. The hybrid layer was excellent for the immobilization of tyrosinase (Tyr), which allowed an amperometric detection of BPA with a limit of detection of 0.011 μM in the concentration range from 0.05 to 20 μM. Detection was also possible in real water samples with recoveries in the range of 92–105%. The improved sensing performance is attributed to the combined effect of the large surface area and porosity of PA6/PAH nanofibers, the catalytic activity of AuNPs, and oxidoreductase ability of Tyr. These results provide a route for novel biosensing architectures to monitor BPA and other EDCs in water resources.
Collapse
|
33
|
Kaya SI, Cetinkaya A, Ozkan SA. Latest Advances in Determination of Bisphenols with Nanomaterials, Molecularly Imprinted Polymers and Aptamer Based Electrochemical Sensors. Crit Rev Anal Chem 2021; 52:1223-1243. [PMID: 33475425 DOI: 10.1080/10408347.2020.1864719] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Contamination of environmental sources such as soils, sediments and rivers and human exposure caused by several endocrine disrupting compounds (EDCs) are considered as the most challenging issues of today's world. EDCs cover a wide variety of compounds ranging from phthalates to parabens and bisphenols (BPs) are the leading group among them. BPs are widely used during the production of different plastic materials such as food and beverage containers, toys, medical equipment and baby bottles that we use in every aspect of our lives. BPs may migrate from those products to different media under certain conditions and this situation causes chronic exposure for humans and other creatures in the environment. Especially bisphenol A (BPA) and its other analogues such as bisphenol F, bisphenol S and tetrabromobisphenol that have similar structures and are preferred as alternatives to BPA cause harmful adverse effects such as endocrine disruption, neurotoxicity, genotoxicity and cytotoxicity. There are legal restrictions and prohibitions by the European Union (EU) in order to prevent possible harmful effects. Therefore, it is important to develop highly sensitive, fast, easy to use and cheap sensors for the determination of BPs in biological, environmental and commercial samples. Electrochemical sensors, which are one of the most widely, used analytical techniques, provide these conditions. Additionally, it is possible to enhance the performance of electrochemical sensors with nanomaterials, molecularly imprinted polymers or aptamer based technologies. This review aims to give comprehensive information about BPs with summarizing most recent applications of electrochemical sensors for their determination in different samples.
Collapse
Affiliation(s)
- S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
34
|
Tajik S, Beitollahi H, Jang HW, Shokouhimehr M. A simple and sensitive approach for the electrochemical determination of amaranth by a Pd/GO nanomaterial-modified screen-printed electrode. RSC Adv 2020; 11:278-287. [PMID: 35423012 PMCID: PMC8690309 DOI: 10.1039/d0ra08723h] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 11/21/2020] [Indexed: 11/30/2022] Open
Abstract
It is essential to develop easy-to-use sensors towards a better monitoring of food additives so that human health can be positively influenced. A type of critical food additive that is widely used in making soft drinks and diverse foodstuff is called amaranth. This study aimed at presenting a novel Pd/GO nanomaterial-modified screen-printed electrode (Pd/GO/SPE), which is responsible for providing a sensing interface during the process of specifying the electrochemical features of amaranth. The morphology and structure of the Pd/GO nanomaterial was investigated by Fourier-transform infrared spectroscopy, thermal gravimetric analysis, X-ray photoelectron spectroscopy, X-ray diffraction, energy-dispersive X-ray spectroscopy, scanning transmission electron microscopy, and high-resolution transmission electron microscopy. When the optimized conditions was adjusted, Pd/GO/SPE proved to be a capable sensor for conducting a very sensitive sensing towards the amaranth under a common working situation of 575 mV. In this regard, it was embarked on measuring some of the sensor features, including its sensitivity, linear dynamic range, and detection limit for amaranth with the values of 0.0948 μA μM-1, 0.08 μM-360.0 μM and 30.0 nM were obtained, respectively.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences Kerman Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| |
Collapse
|
35
|
Tajik S, Beitollahi H, Mohammadi SZ, Azimzadeh M, Zhang K, Van Le Q, Yamauchi Y, Jang HW, Shokouhimehr M. Recent developments in electrochemical sensors for detecting hydrazine with different modified electrodes. RSC Adv 2020; 10:30481-30498. [PMID: 35516027 PMCID: PMC9056357 DOI: 10.1039/d0ra03288c] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Accepted: 07/28/2020] [Indexed: 12/13/2022] Open
Abstract
The detection of hydrazine (HZ) is an important application in analytical chemistry. There have been recent advancements in using electrochemical detection for HZ. Electrochemical detection for HZ offers many advantages, e.g., high sensitivity, selectivity, speed, low investment and running cost, and low laboriousness. In addition, these methods are robust, reproducible, user-friendly, and compatible with the concept of green analytical chemistry. This review is devoted to the critical comparison of electrochemical sensors and measuring protocols used for the voltammetric and amperometric detection of the most frequently used HZ in water resources with desirable recovery. Attention is focused on the working electrode and its possible modification which is crucial for further development.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences Kerman Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
| | | | - Mostafa Azimzadeh
- Medical Nanotechnology & Tissue Engineering Research Center, Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences PO Box 89195-999 Yazd Iran
| | - Kaiqiang Zhang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Quyet Van Le
- Institute of Research and Development, Duy Tan University Da Nang 550000 Vietnam
| | - Yusuke Yamauchi
- School of Chemical Engineering, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland Brisbane Queensland 4072 Australia
- International Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science (NIMS) Tsukuba 3050044 Japan
- Department of Plant and Environmental New Resources, Kyung Hee University 1732 Deogyeong-daero, Giheung-gu Yongin-si Gyeonggi-do 446-701 Republic of Korea
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| |
Collapse
|
36
|
Tajik S, Beitollahi H, Nejad FG, Shoaie IS, Khalilzadeh MA, Asl MS, Van Le Q, Zhang K, Jang HW, Shokouhimehr M. Recent developments in conducting polymers: applications for electrochemistry. RSC Adv 2020; 10:37834-37856. [PMID: 35515168 PMCID: PMC9057190 DOI: 10.1039/d0ra06160c] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 09/15/2020] [Indexed: 01/07/2023] Open
Abstract
Scientists have categorized conductive polymers as materials having strongly reversible redox behavior and uncommon combined features of plastics and metal. Because of their multifunctional characteristics, e.g., simplistic synthesis, acceptable environmental stability, beneficial optical, electronic, and mechanical features, researchers have largely considered them for diverse applications. Therefore, their capability of catalyzing several electrode reactions has been introduced as one of their significant features. A thin layer of the conducting polymer deposited on the substrate electrode surface can augment the electrode process kinetics of several solution species. Such electrocatalytic procedures with modified conducting polymer electrodes can create beneficial utilization in diverse fields of applied electrochemistry. This review article explores typical recent applications of conductive polymers (2016–2020) as active electrode materials for energy storage applications, electrochemical sensing, and conversion fields such as electrochemical supercapacitors, lithium-ion batteries, fuel cells, and solar cells. Scientists have categorized conductive polymers as materials having strongly reversible redox behavior and uncommon combined features of plastics and metal.![]()
Collapse
|