1
|
Guo W, Sun YC, Zhang LY, Yin XM. Gastrointestinal/genitourinary adverse event after intensity modulated versus three-dimensional primary radiation therapy in the treatment of prostate cancer: systematic review and meta-analysis. J Cancer 2023; 14:2878-2888. [PMID: 37781069 PMCID: PMC10539562 DOI: 10.7150/jca.87626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 08/29/2023] [Indexed: 10/03/2023] Open
Abstract
Objective: Prostate cancer (PCa) is one of the most common cancers in the world. The potential benefits of intensity modulated radiation therapy (IMRT) over three-dimensional conformal radiation therapy (3D-CRT) for PCa primary radiation therapy treatment have not yet been clarified. Therefore, this meta-analysis was conducted to assess whether IMRT could improve clinical outcomes in comparison with 3D-CRT in patients diagnosed with PCa. Materials and methods: Relevant studies were identified through searching related databases till December, 2022. Hazard ratio (HR) or risk ratio (RR) with its corresponding 95% confidence interval (CI) was used as pooled statistics for all analyses. Results: The incidence of grade 2 or worse acute adverse gastrointestinal (GI) event was analyzed and the pooled data revealed a clear decreasing trend in the IMRT compared with 3D-CRT (RR=0.62, 95% CI: 0.45-0.84, p=0.002). IMRT slightly increased the grade ≥ 2 acute genitourinary (GU) adverse event in comparison with the 3D-CRT (RR=1.10, 95% CI: 1.02-1.19, p=0.015). The IMRT and the 3D-CRT of patients showed no substantial differences in grade ≥ 2 late GI adverse event (RR =0.62, 95% CI: 0.36-1.09, p=0.1). In those included studies, there was no significant difference between IMRT and 3D-CRT in grade 2-4 late GU adverse event (RR =1.08, 95% CI: 0.77-1.51, p=0.65). There was a significant difference in biochemical control favoring IMRT (RR =1.13, 95% CI: 1.05-1.22, p=0.002). IMRT showed modest increase in biochemical control in comparison with 3D-CRT. Conclusion: In general, based on the above results, IMRT should be considered as a better choice for the treatment of PCa. More randomized controlled trials are needed to determine the subset of patients diagnosed with PCa.
Collapse
Affiliation(s)
- Wei Guo
- Department of Radiation Oncology, Hebei Province Cangzhou Hospital of Integrated Traditional and Western Medicine, Cangzhou, Hebei, 061000, China
| | - Yun-Chuan Sun
- Department of Radiation Oncology, Hebei Province Cangzhou Hospital of Integrated Traditional and Western Medicine, Cangzhou, Hebei, 061000, China
| | - Li-Yuan Zhang
- Key Laboratory of Endocrinology of National Health Commission, Department of Endocrinology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, 100730, China
| | - Xiao-Ming Yin
- Department of Radiation Oncology, Hebei Province Cangzhou Hospital of Integrated Traditional and Western Medicine, Cangzhou, Hebei, 061000, China
| |
Collapse
|
2
|
Lee JW, Chung MJ. Prostate only radiotherapy using external beam radiotherapy: A clinician's perspective. World J Clin Cases 2022; 10:10428-10434. [PMID: 36312490 PMCID: PMC9602254 DOI: 10.12998/wjcc.v10.i29.10428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 08/12/2022] [Accepted: 08/30/2022] [Indexed: 02/05/2023] Open
Abstract
Prostate-only radiotherapy (PORT) is widely used as the definitive treatment for localized prostate cancer. Prostate cancer has an α/β ratio; therefore, radiotherapy (RT) with a large fraction size is biologically effective for tumor control. The current external beam RT technique for PORT has been improved from three-dimensional conformal RT to intensity-modulated, stereotactic body, and image-guided RTs. These methods are associated with reduced radiation exposure to normal tissues, decreasing urinary and bowel toxicity. Several trials have shown improved local control with dose escalation through the aforementioned methods, and the efficacy and safety of intensity-modulated and stereotactic body RTs have been proven. However, the management of RT in patients with prostate cancer has not been fully elucidated. As a clinician, there are several concerns regarding the RT volume and dose considering the patient's age and comorbidities. Therefore, this review aimed to discuss the radiobiological basis and external beam technical advancements in PORT for localized prostate cancer from a clinician's perspective.
Collapse
Affiliation(s)
- Jeong Won Lee
- Department of Radiation Oncology, Daegu Catholic University School of Medicine, Daegu 42472, South Korea
| | - Mi Joo Chung
- Department of Radiation Oncology, Hanyang University Hanmaeum Changwon Hospital, Changwon 51139, South Korea
| |
Collapse
|
3
|
Kim TH, Lee JJB, Cho J. Prostate-Specific Antigen Bounce after 125I Brachytherapy Using Stranded Seeds with Intraoperative Optimization for Prostate Cancer. Cancers (Basel) 2022; 14:4907. [PMID: 36230829 PMCID: PMC9563276 DOI: 10.3390/cancers14194907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/17/2022] [Accepted: 10/06/2022] [Indexed: 11/16/2022] Open
Abstract
Prostate-specific antigen (PSA) bounce is common in patients undergoing 125I brachytherapy (BT), and our study investigated its clinical features. A total of 100 patients who underwent BT were analyzed. PSA bounce and large bounce were defined as an increase of ≥0.2 and ≥2.0 ng/mL above the initial PSA nadir, respectively, with a subsequent decline without treatment. Biochemical failure was defined using the Phoenix definition (nadir +2 ng/mL), except for a large bounce. With a median follow-up of 49 months, 45% and 7% of the patients experienced bounce and large bounce, respectively. The median time to bounce was 24 months, and the median PSA value at the bounce spike was 1.62 ng/mL, a median raise of 0.44 ng/mL compared to the pre-bounce nadir. The median time to bounce recovery was 4 months. The post-bounce nadir was obtained at a median of 36 months after low-dose-rate BT. On univariate analysis, age, the PSA nadir value at 2 years, and prostate volume were significant factors for PSA bounce. The PSA nadir value at 2 years remained significant in multivariate analysis. We should carefully monitor young patients with high prostate volume having a >0.5 PSA nadir value at 2 years for PSA bounce.
Collapse
Affiliation(s)
- Tae Hyung Kim
- Yonsei Cancer Center, Department of Radiation Oncology, Yonsei University College of Medicine, Seoul 03722, Korea
- Department of Radiation Oncology, Nowon Eulji Medical Center, Eulji University School of Medicine, Seoul 01830, Korea
| | - Jason Joon Bock Lee
- Yonsei Cancer Center, Department of Radiation Oncology, Yonsei University College of Medicine, Seoul 03722, Korea
- Department of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181, Korea
| | - Jaeho Cho
- Yonsei Cancer Center, Department of Radiation Oncology, Yonsei University College of Medicine, Seoul 03722, Korea
| |
Collapse
|
4
|
Cross-modality applicability of rectal normal tissue complication probability models from photon- to proton-based radiotherapy. Radiother Oncol 2020; 142:253-260. [DOI: 10.1016/j.radonc.2019.09.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 09/20/2019] [Accepted: 09/21/2019] [Indexed: 11/21/2022]
|
5
|
Choi HS, Kang KM, Jeong BK, Song JH, Lee YH, Ha IB, Kam SC, Hwa JS, Hyun JS, Do J, Jeong DH, Jeong H. Analysis of Motion-dependent Clinical Outcome of Tumor Tracking Stereotactic Body Radiotherapy for Prostate Cancer. J Korean Med Sci 2018; 33:e107. [PMID: 29607633 PMCID: PMC5879038 DOI: 10.3346/jkms.2018.33.e107] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 01/26/2018] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND To analyze clinical outcome of CyberKnife (CK) tumor-tracking stereotactic body radiotherapy (SBRT) for prostate cancer (Pca) according to the magnitude of intra-fractional prostate motion. METHODS Medical records and daily treatment logs for 71 patients who received CK tumor-tracking SBRT were retrospectively analyzed. Statistical relationships between prostate motion and various outcome results, including local recurrence (LR), biochemical failure (BF), and treatment-related toxicity, were investigated in order to evaluate motion-dependent efficacy of tumor-tracking SBRT for Pca. RESULTS In a total 71 patients, 3 (4.2%) patients with LR, 12 (16.9%) patients with BF, and 22 (31%) patients with grade-II or worse toxicities to rectal or bladder (22 to rectal, 22 to bladder and 8 patients to both) were observed in a median follow-up of 47 months. Magnitudes of intra-fractional tumor motion along superior-inferior, right-left, and anterior-posterior (AP) axes were 0.15 ± 0.31, 0.12 ± 0.19, and 0.73 ± 0.32 mm, respectively. Radial magnitude was estimated to be 1.0 ± 0.35 mm. Intra-fractional movement was not significantly correlated with tumor control. However, it was significant correlated with the incidence of grade-II or worse toxicity to rectum or bladder particularly when tumor motion was in the AP axis. CONCLUSION Our quantitative results revealed that toxicity related to SBRT treatment was highly sensitive to intra-fractional prostate movements, although local-tumor control was not affected by such movements. Our results demonstrate that precise motion correction is essential in prostate SBRT, even if it seems to be small.
Collapse
Affiliation(s)
- Hoon Sik Choi
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Ki Mun Kang
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
| | - Bae Kwon Jeong
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - Jin Ho Song
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
| | - Yun Hee Lee
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - In Bong Ha
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - Sung Chul Kam
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Urology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Jeong Seok Hwa
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Urology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - Jae Seog Hyun
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Urology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - Jungmo Do
- Department of Urology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea
| | - Dong Hyeok Jeong
- Research Center, Dongnam Institute of Radiological and Medical Science, Busan, Korea
| | - Hojin Jeong
- Institute of Health Science, Gyeongsang National University, Jinju, Korea
- Department of Radiation Oncology, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Korea.
| |
Collapse
|
6
|
Wu CC, Wuu YR, Yanagihara T, Jani A, Xanthopoulos EP, Tiwari A, Wright JD, Burke WM, Hou JY, Tergas AI, Deutsch I. Rectal balloon use limits vaginal displacement, rectal dose, and rectal toxicity in patients receiving IMRT for postoperative gynecological malignancies. Med Dosim 2017; 43:23-29. [PMID: 28870525 DOI: 10.1016/j.meddos.2017.07.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 06/20/2017] [Accepted: 07/25/2017] [Indexed: 10/18/2022]
Abstract
Pelvic radiotherapy for gynecologic malignancies traditionally used a 4-field box technique. Later trials have shown the feasibility of using intensity-modulated radiotherapy (IMRT) instead. But vaginal movement between fractions is concerning when using IMRT due to greater conformality of the isodose curves to the target and the resulting possibility of missing the target while the vagina is displaced. In this study, we showed that the use of a rectal balloon during treatment can decrease vaginal displacement, limit rectal dose, and limit acute and late toxicities. Little is known regarding the use of a rectal balloon (RB) in treating patients with IMRT in the posthysterectomy setting. We hypothesize that the use of an RB during treatment can limit rectal dose and acute and long-term toxicities, as well as decrease vaginal cuff displacement between fractions. We performed a retrospective review of patients with gynecological malignancies who received postoperative IMRT with the use of an RB from January 1, 2012 to January 1, 2015. Rectal dose constraint was examined as per Radiation Therapy Oncology Group (RTOG) 1203 and 0418. Daily cone beam computed tomography (CT) was performed, and the average (avg) displacement, avg magnitude, and avg magnitude of vector were calculated. Toxicity was reported according to RTOG acute radiation morbidity scoring criteria. Acute toxicity was defined as less than 90 days from the end of radiation treatment. Late toxicity was defined as at least 90 days after completing radiation. Twenty-eight patients with postoperative IMRT with the use of an RB were examined and 23 treatment plans were reviewed. The avg rectal V40 was 39.3% ± 9.0%. V30 was65.1% ± 10.0%. V50 was 0%. Separate cone beam computed tomography (CBCT) images (n = 663) were reviewed. The avg displacement was as follows: superior 0.4 + 2.99 mm, left 0.23 ± 4.97 mm, and anterior 0.16 ± 5.18 mm. The avg magnitude of displacement was superior/inferior 2.22 ± 2.04 mm, laterally 3.41 ± 3.62 mm, and anterior/posterior 3.86 ± 3.45 mm. The avg vector magnitude was 6.60 ± 4.14 mm. For acute gastrointestinal (GI) toxicities, 50% experienced grade 1 toxicities and 18% grade 2 GI toxicities. For acute genitourinary (GU) toxicities, 21% had grade 1 and 18% had grade 2 toxicities. For late GU toxicities, 7% had grade 1 and 4% had grade 2 toxicities. RB for gynecological patients receiving IMRT in the postoperative setting can limit V40 rectal dose and vaginal displacement. Although V30 constraints were not met, patients had limited acute and late toxicities. Further studies are needed to validate these findings.
Collapse
Affiliation(s)
- Cheng-Chia Wu
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Yen-Ruh Wuu
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Theodore Yanagihara
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Ashish Jani
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Eric P Xanthopoulos
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Akhil Tiwari
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY
| | - Jason D Wright
- Department of Gynecologic Oncology, Columbia University Medical Center, New York, NY
| | - William M Burke
- Department of Gynecologic Oncology, Columbia University Medical Center, New York, NY
| | - June Y Hou
- Department of Gynecologic Oncology, Columbia University Medical Center, New York, NY
| | - Ana I Tergas
- Department of Gynecologic Oncology, Columbia University Medical Center, New York, NY
| | - Israel Deutsch
- Department of Radiation Oncology, Columbia University Medical Center, New York, NY; Herbert Irving Comprehensive Cancer Center, Columbia University Medical Center, New York, NY.
| |
Collapse
|
7
|
Sung W, Park JI, Kim JI, Carlson J, Ye SJ, Park JM. Monte Carlo simulation for scanning technique with scattering foil free electron beam: A proof of concept study. PLoS One 2017; 12:e0177380. [PMID: 28493940 PMCID: PMC5426680 DOI: 10.1371/journal.pone.0177380] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 04/26/2017] [Indexed: 11/18/2022] Open
Abstract
This study investigated the potential of a newly proposed scattering foil free (SFF) electron beam scanning technique for the treatment of skin cancer on the irregular patient surfaces using Monte Carlo (MC) simulation. After benchmarking of the MC simulations, we removed the scattering foil to generate SFF electron beams. Cylindrical and spherical phantoms with 1 cm boluses were generated and the target volume was defined from the surface to 5 mm depth. The SFF scanning technique with 6 MeV electrons was simulated using those phantoms. For comparison, volumetric modulated arc therapy (VMAT) plans were also generated with two full arcs and 6 MV photon beams. When the scanning resolution resulted in a larger separation between beams than the field size, the plan qualities were worsened. In the cylindrical phantom with a radius of 10 cm, the conformity indices, homogeneity indices and body mean doses of the SFF plans (scanning resolution = 1°) vs. VMAT plans were 1.04 vs. 1.54, 1.10 vs. 1.12 and 5 Gy vs. 14 Gy, respectively. Those of the spherical phantom were 1.04 vs. 1.83, 1.08 vs. 1.09 and 7 Gy vs. 26 Gy, respectively. The proposed SFF plans showed superior dose distributions compared to the VMAT plans.
Collapse
Affiliation(s)
- Wonmo Sung
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea
| | - Jong In Park
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea
| | - Jung-in Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Joel Carlson
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea
| | - Sung-Joon Ye
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
- Institute for Smart System, Robotics Research Laboratory for Extreme Environments, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
- * E-mail:
| |
Collapse
|
8
|
Ahn BS, Park SY, Park JM, Choi CH, Chun M, Kim JI. Dosimetric effects of sectional adjustments of collimator angles on volumetric modulated arc therapy for irregularly-shaped targets. PLoS One 2017; 12:e0174924. [PMID: 28384262 PMCID: PMC5383152 DOI: 10.1371/journal.pone.0174924] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Accepted: 03/18/2017] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To calculate an optimal collimator angle at each of sectional arcs in a full-arc volumetric modulated arc therapy (VMAT) plan and evaluate dosimetric quality of these VMAT plans comparing full-arc VMAT plans with a fixed collimator angle. METHODS Seventeen patients who had irregularly-shaped target in abdominal, head and neck, and chest cases were selected retrospectively. To calculate an optimal collimator angle at each of sectional arcs in VMAT, integrated MLC apertures which could cover all shapes of target determined by beam's-eye view (BEV) within angular sections were obtained for each VMAT plan. The angular sections were 40°, 60°, 90° and 120°. When the collimator settings were rotated at intervals of 2°, we obtained the optimal collimator angle to minimize area size difference between the integrated MLC aperture and collimator settings with 5 mm-margins to the integrated MLC aperture. The VMAT plans with the optimal collimator angles (Colli-VMAT) were generated in the EclipseTM. For comparison purposes, one full-arc VMAT plans with a fixed collimator angles (Std-VMAT) were generated. The dose-volumetric parameters and total MUs were evaluated. RESULTS The mean dose-volumetric parameters for target volume of Colli-VMAT were comparable to Std-VMAT. Colli-VMAT improved sparing of most normal organs but for brain stem, compared to Std-VMAT for all cases. There were decreasing tendencies in mean total MUs with decreasing angular section. The mean total MUs for Colli-VMAT with the angular section of 40° (434 ± 95 MU, 317 ± 81 MU, and 371 ± 43 MU for abdominal, head and neck, and chest cases, respectively) were lower than those for Std-VMAT (654 ± 182 MU, 517 ± 116 MU, and 533 ± 25 MU, respectively). CONCLUSIONS For an irregularly-shaped target, Colli-VMAT with the angular section of 40° reduced total MUs and improved sparing of normal organs, compared to Std-VMAT.
Collapse
Affiliation(s)
- Beom Seok Ahn
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
| | - So-Yeon Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Chang Heon Choi
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Minsoo Chun
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jung-in Kim
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
- Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- * E-mail:
| |
Collapse
|
9
|
Moon DH, Efstathiou JA, Chen RC. What is the best way to radiate the prostate in 2016? Urol Oncol 2016; 35:59-68. [PMID: 27395453 DOI: 10.1016/j.urolonc.2016.06.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 05/20/2016] [Accepted: 06/04/2016] [Indexed: 12/25/2022]
Abstract
Prostate cancer treatment with definitive radiation therapy (RT) has evolved dramatically in the past 2 decades. From the initial 2-dimensional planning using X-rays, advances in technology led to 3-dimensional conformal RT, which used computerized tomography-based planning. This has allowed delivery of higher doses of radiation to the prostate while reducing dose to the surrounding organs, resulting in improved cancer control. Today, intensity-modulated RT (IMRT) is considered standard, where radiation beams of different shapes and intensities can be delivered from a wide range of angles, thus further decreasing doses to normal organs and likely reducing treatment-related toxicity. In addition, image guidance ascertains the location of the prostate before daily treatment delivery. Brachytherapy is the placement of radioactive seeds directly in the prostate, and has a long track record as a monotherapy for low-risk prostate cancer patients with excellent long-term cancer control and quality of life outcomes. Recent studies including several randomized trials support the use of brachytherapy in combination with external beam RT for higher-risk patients. RT for prostate cancer continues to evolve. Proton therapy has a theoretical advantage over photons as it deposits most of the dose at a prescribed depth with a rapid dose fall-off thereafter; therefore it reduces some doses delivered to the bladder and rectum. Prospective studies have shown the safety and efficacy of proton therapy for prostate cancer, but whether it leads to improved patient outcomes compared to IMRT is unknown. Hypofractionated RT delivers a larger dose of daily radiation compared to conventional IMRT, and thus reduces the overall treatment time and possibly cost. An extreme form of hypofractionation is stereotactic body radiation therapy where highly precise radiation is used and treatment is completed in a total of 4 to 5 sessions. These techniques take advantage of the biological characteristic of prostate cancer, which is more sensitive to larger radiation doses per fraction, and therefore could be more effective than conventional IMRT. Multiple randomized trials have demonstrated noninferiority of moderately hypofractionated RT compared to conventional fractionation. There is also a growing body of data demonstrating the safety and efficacy of stereotactic body radiation therapy for low- and intermediate-risk prostate cancer.
Collapse
Affiliation(s)
- Dominic H Moon
- Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC
| | - Jason A Efstathiou
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Ronald C Chen
- Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC; Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC.
| |
Collapse
|
10
|
Timely tumor response analysis after preoperative chemoradiotherapy and curative surgery in locally advanced rectal cancer: A multi-institutional study for optimal surgical timing in rectal cancer. Radiother Oncol 2016; 119:512-8. [DOI: 10.1016/j.radonc.2016.03.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Revised: 03/02/2016] [Accepted: 03/27/2016] [Indexed: 11/24/2022]
|
11
|
Hegazy MW, Mahmood RI, Al Otaibi MF, Khalil EM. Hypofractionated Volumetric Modulated Arc Radiotherapy with simultaneous Elective Nodal Irradiation is feasible in prostate cancer patients: A single institution experience. J Egypt Natl Canc Inst 2016; 28:101-10. [DOI: 10.1016/j.jnci.2016.04.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Revised: 04/03/2016] [Accepted: 04/04/2016] [Indexed: 11/16/2022] Open
|
12
|
Yu T, Zhang Q, Zheng T, Shi H, Liu Y, Feng S, Hao M, Ye L, Wu X, Yang C. The Effectiveness of Intensity Modulated Radiation Therapy versus Three-Dimensional Radiation Therapy in Prostate Cancer: A Meta-Analysis of the Literatures. PLoS One 2016; 11:e0154499. [PMID: 27171271 PMCID: PMC4865138 DOI: 10.1371/journal.pone.0154499] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 04/14/2016] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND AND PURPOSE Intensity modulated radiation therapy (IMRT) can deliver higher doses with less damage of healthy tissues compared with three-dimensional radiation therapy (3DCRT). However, for the scenarios with better clinical outcomes for IMRT than 3DCRT in prostate cancer, the results remain ambiguous. We performed a meta-analysis to assess whether IMRT can provide better clinical outcomes in comparison with 3DCRT in patients diagnosed with prostate cancer. MATERIALS AND METHODS We conducted a meta-analysis of 23 studies (n = 9556) comparing the clinical outcomes, including gastrointestinal (GI) toxicity, genitourinary (GU) toxicity, biochemical controland overall survival (OS). RESULTS IMRT was significantly associated with decreased 2-4 grade acute GI toxicity [risk ratio (RR) = 0.59 (95% confidence interval (CI), 0.44, 0.78)], late GI toxicity [RR = 0.54, 95%CI (0.38, 0.78)], late rectal bleeding [RR = 0.48, 95%CI (0.27, 0.85)], and achieved better biochemical control[RR = 1.17, 95%CI (1.08, 1.27)] in comparison with 3DCRT. IMRT and 3DCRT remain the same in regard of grade 2-4 acute rectal toxicity [RR = 1.03, 95%CI (0.45, 2.36)], late GU toxicity [RR = 1.03, 95%CI (0.82, 1.30)] and overall survival [RR = 1.07, 95%CI (0.96, 1.19)], while IMRT slightly increased the morbidity of grade 2-4 acute GU toxicity [RR = 1.08, 95%CI (1.00, 1.17)]. CONCLUSIONS Although some bias cannot be ignored, IMRT appears to be a better choice for the treatment of prostate cancer when compared with 3DCRT.
Collapse
Affiliation(s)
- Ting Yu
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Qiongwen Zhang
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
- State Key Laboratory of Biotherapy and Department of Head and Neck Oncology, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Tianying Zheng
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Huashan Shi
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
- State Key Laboratory of Biotherapy and Department of Head and Neck Oncology, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Yang Liu
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Shijian Feng
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Meiqin Hao
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Lei Ye
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Xueqian Wu
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| | - Cheng Yang
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, PRC
| |
Collapse
|
13
|
Fields EC, Weiss E. A practical review of magnetic resonance imaging for the evaluation and management of cervical cancer. Radiat Oncol 2016; 11:15. [PMID: 26830954 PMCID: PMC4736634 DOI: 10.1186/s13014-016-0591-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Accepted: 01/20/2016] [Indexed: 02/06/2023] Open
Abstract
Cervical cancer is a leading cause of mortality in women worldwide. Staging and management of cervical cancer has for many years been based on clinical exam and basic imaging such as intravenous pyelogram and x-ray. Unfortunately, despite advances in radiotherapy and the inclusion of chemotherapy in the standard plan for locally advanced disease, local control has been unsatisfactory. This situation has changed only recently with the increasing implementation of magnetic resonance image (MRI)-guided brachytherapy. The purpose of this article is therefore to provide an overview of the benefits of MRI in the evaluation and management of cervical cancer for both external beam radiotherapy and brachytherapy and to provide a practical approach if access to MRI is limited.
Collapse
Affiliation(s)
- Emma C Fields
- Virginia Commonwealth University, Richmond, VA, USA.
| | | |
Collapse
|
14
|
Jeong S, Lee JH, Chung MJ, Lee SW, Lee JW, Kang DG, Kim SH. Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization. Medicine (Baltimore) 2016; 95:e2387. [PMID: 26765418 PMCID: PMC4718244 DOI: 10.1097/md.0000000000002387] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients.We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediate to high-risk prostate cancer. They received whole pelvic intensity-modulated radiotherapy (IMRT). They underwent daily endorectal ballooning and enema to limit intrapelvic organ movement. The mean and standard deviation (SD) of daily translational shifts in right-to-left (X), anterior-to-posterior (Y), and superior-to-inferior (Z) were evaluated for systemic and random error.The mean ± SD of systemic error (Σ) in X, Y, Z, and roll was 2.21 ± 3.42 mm, -0.67 ± 2.27 mm, 1.05 ± 2.87 mm, and -0.43 ± 0.89°, respectively. The mean ± SD of random error (δ) was 1.95 ± 1.60 mm in X, 1.02 ± 0.50 mm in Y, 1.01 ± 0.48 mm in Z, and 0.37 ± 0.15° in roll. The calculated proper PTV margins that cover >95% of the target on average were 8.20 (X), 5.25 (Y), and 6.45 (Z) mm. Mean systemic geometrical shifts of IMRT were not statistically different in all transitional and three-dimensional shifts from early to late weeks. There was no grade 3 or higher gastrointestinal or genitourianry toxicity.The whole pelvic IMRT technique is a feasible and effective modality that limits intrapelvic organ motion and reduces setup uncertainties. Proper margins for the PTV can be determined by using geometric shifts data.
Collapse
Affiliation(s)
- Songmi Jeong
- From the Department of Radiation Oncology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (SJ, JHL, MJC, SWL, DGK, SHK); and Department of Radiation Oncology, Kyungpook National University Hospital, Daegu, Korea (JWL)
| | | | | | | | | | | | | |
Collapse
|
15
|
Park SY, Park JM, Kim JI, Kim H, Kim IH, Ye SJ. Textural feature calculated from segmental fluences as a modulation index for VMAT. Phys Med 2015; 31:981-990. [DOI: 10.1016/j.ejmp.2015.07.143] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 07/07/2015] [Accepted: 07/13/2015] [Indexed: 10/23/2022] Open
|
16
|
Detti B, Bonomo P, Masi L, Doro R, Cipressi S, Iermano C, Bonucci I, Franceschini D, Di Cataldo V, Di Brina L, Baki M, Simontacchi G, Meattini I, Carini M, Serni S, Nicita G, Livi L. Cyberknife Treatment for Low and Intermediate Risk Prostate Cancer. Cancer Invest 2015; 33:188-92. [DOI: 10.3109/07357907.2015.1019679] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
17
|
Park SY, Park JM, Sung W, Kim IH, Ye SJ. Texture analysis on the edge-enhanced fluence of VMAT. Radiat Oncol 2015; 10:74. [PMID: 25890104 PMCID: PMC4386104 DOI: 10.1186/s13014-015-0382-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Accepted: 03/16/2015] [Indexed: 11/25/2022] Open
Abstract
Background Textural features of edge-enhanced fluence were analysed to quantify modulation degree of volumetric modulated arc therapy (VMAT) plans. Methods Twenty prostate and twenty head and neck VMAT plans were retrospectively selected. Fluences of VMAT plans were generated by integration of monitor units shaped by multi-leaf collimators (MLCs) at each control point. When generating fluences, the values of pixels representing MLC tips were doubled to prevent smearing out of small or irregular fields (edge-enhancement). Six kinds of textural features, including angular second moment, inverse difference moment, contrast, variance, correlation and entropy, were calculated with particular displacement distances (d) of 1, 5 and 10. Plan delivery accuracy was evaluated by gamma-index method, mechanical parameter differences between plan and delivery and differences in dose-volumetric parameters between plan and delivery. Spearman’s correlation coefficients (rs) were calculated between the values of textural features and VMAT delivery accuracy. Results The rs values of contrast (d = 1) with edge-enhancement to global gamma passing rates with 2%/2 mm, 1%/2 mm and 2%/1 mm were 0.546 (p < 0.001), 0.744 (p < 0.001) and 0.487 (p = 0.001), respectively. Those with local 2%/2 mm, 1%/2 mm and 2%/1 mm were 0.588, 0.640 and 0.644, respectively (all with p < 0.001). The rs values of contrast (d = 1) to MLC and gantry angle errors were -0.853 and 0.655, respectively (all with p < 0.001). The contrast (d = 1) showed statistically significant rs values in 11 dose-volumetric parameter differences from a total of 35 cases, and generally showed better correlations to plan delivery accuracy than did previously suggested textural features with non-edge-enhanced fluences, as well as conventional modulation indices. Conclusions Contrast (d = 1) with edge-enhanced fluences could be used as modulation index for VMAT.
Collapse
Affiliation(s)
- So-Yeon Park
- Interdiciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. .,Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
| | - Jong Min Park
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. .,Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea. .,Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea.
| | - Wonmo Sung
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea.
| | - Il Han Kim
- Interdiciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. .,Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea. .,Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.
| | - Sung-Joon Ye
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. .,Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea. .,Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Seoul National University Graduate School of Convergence Science and Technology, Seoul, Republic of Korea.
| |
Collapse
|