Moat SJ, Bonham JR, Cavanagh C, Birch M, Griffith C, Shakespeare L, Le Masurier C, Manfredonia C, Hird B, Goddard P, Smith S, Wainwright L, Carling RS, Cundick J, Jenkinson F, Collingwood C, Flynn N, Taj N, Mirzazadeh M, Ramgoolam T, Robinson L, Headley A, Morgan T, Elliman D, Tetlow L. Consistency in the Assessment of Dried Blood Spot Specimen Size and Quality in U.K. Newborn Screening Laboratories. Int J Neonatal Screen 2024; 10:60. [PMID: 39311362 PMCID: PMC11417764 DOI: 10.3390/ijns10030060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 08/30/2024] [Accepted: 08/30/2024] [Indexed: 09/26/2024] Open
Abstract
In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK 'acceptable' avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images (n = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1-16) and in the second EQA distribution was 7 (0-16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = -0.734, p = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.
Collapse
Affiliation(s)
- Stuart J. Moat
- Wales Newborn Screening Laboratory, Department of Medical Biochemistry, Immunology & Toxicology, University Hospital of Wales, Cardiff CF14 4XW, UK
- University Hospital Wales, School of Medicine, Cardiff University, Cardiff CF14 4XW, UK
| | - James R. Bonham
- Clinical Chemistry, Sheffield Children’s NHSFT, Sheffield S10 2TH, UK
| | | | - Margaret Birch
- Health Protection & Screening Services, Public Health Wales, Cardiff CF10 4BZ, UK
| | - Caroline Griffith
- Biochemical Genetics, Specialist Laboratory Medicine, St James University Hospital, Leeds LS9 7TF, UK
| | | | - Clare Le Masurier
- South West Newborn Screening and Metabolic Laboratory, Severn Pathology, Southmead Hospital, Bristol BS10 5NB, UK
| | - Claire Manfredonia
- Newborn Screening Laboratory, Manchester University NHSFT, Manchester M13 9WL, UK
| | - Beverly Hird
- Newborn Screening Laboratory, Manchester University NHSFT, Manchester M13 9WL, UK
| | - Philippa Goddard
- Newborn Screening and Biochemical Genetics, Paediatric Laboratory Medicine, Birmingham Children’s Hospital, Steelhouse Lane, Birmingham B4 6NH, UK
| | - Sarah Smith
- Scottish Newborn Screening Laboratory, Queen Elizabeth University Hospital, Glasgow G51 4TF, UK
| | - Laura Wainwright
- Blood Sciences, Portsmouth Hospitals Trust, Portsmouth PO6 3LY, UK
| | - Rachel S. Carling
- Biochemical Sciences, Synnovis, Guys & St Thomas’ NHSFT, London SE1 7EH, UK;
- GKT School of Medical Education, Kings College London, London WC2R 2LS, UK
| | - Jennifer Cundick
- Regional Newborn Screening Laboratory, Royal Victoria Hospital, Belfast BT12 6BA, UK
| | - Fiona Jenkinson
- Newborn Screening, Blood Sciences, Royal Victoria Infirmary, Newcastle upon Tyne NE1 4LP, UK
| | - Catherine Collingwood
- Biochemistry Department, Alder Hey Children’s NHS Foundation Trust, Liverpool L12 2AP, UK
| | - Nick Flynn
- Biochemical Genetics Unit, Cambridge University Hospitals NHSFT, Cambridge CB2 0QQ, UK
| | - Nazia Taj
- Oxford Screening Laboratory, Clinical Biochemistry, Oxford University Hospitals NHSFT, Oxford OX3 9DU, UK
| | - Mehdi Mirzazadeh
- South West Thames Newborn Screening, Epsom & St Helier Hospitals, Carshalton SM5 1AA, UK
| | - Tejswurree Ramgoolam
- Department of Chemical Pathology, Great Ormond Street Hospital for Children, London WC1N 3JH, UK
| | - Liz Robinson
- NHS England, Wellington House, London SE1 8UG, UK
| | - Amy Headley
- NHS England, Wellington House, London SE1 8UG, UK
| | - Tessa Morgan
- NHS England, Wellington House, London SE1 8UG, UK
| | | | - Lesley Tetlow
- Newborn Screening Laboratory, Manchester University NHSFT, Manchester M13 9WL, UK
| |
Collapse
|
2
|
Mandlekar S, Sutaria DS, Yang X, Johnson R, Zou Y, Dean B, Chen L, Sane R, Williams K, Cardenas A, Simon M, Fischer S. Evaluation of Patient-Centric Sample Collection Technologies for Pharmacokinetic Assessment of Large and Small Molecules. Clin Pharmacol Ther 2024; 116:782-794. [PMID: 38671563 DOI: 10.1002/cpt.3272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Accepted: 03/31/2024] [Indexed: 04/28/2024]
Abstract
Low-volume sampling devices offer the promise of lower discomfort and greater convenience for patients, potentially reducing patient burden and enabling decentralized clinical trials. In this study, we determined whether low-volume sampling devices produce pharmacokinetic (PK) data comparable to conventional venipuncture for a diverse set of monoclonal antibodies (mAbs) and small molecules. We adopted an open-label, non-randomized, parallel-group, single-site study design, with four cohorts of 10 healthy subjects per arm. The study drugs, doses, and routes of administration included: crenezumab (15 mg/kg, intravenous infusion), etrolizumab (210 mg, subcutaneous), GDC-X (oral), and hydroxychloroquine (HCQ, 200 mg, oral). Samples were collected after administration of a single dose of each drug using conventional venipuncture and three low-volume capillary devices: TassoOne Plus for liquid blood, Tasso-M20 for dry blood, both applied to the arm, and Neoteryx Mitra® for dry blood obtained from fingertips. Serum/plasma concentrations from venipuncture and TassoOne Plus samples overlapped and PK parameters were comparable for all drugs, except HCQ. After applying a baseline hematocrit value, the dry blood concentrations and PK parameters for the two monoclonal antibodies were comparable to those obtained from venipuncture. For the two small molecules, two bridging strategies were evaluated for converting dry blood concentrations to equivalent plasma concentrations. A baseline hematocrit correction and/or linear regression-based correction was effective for GDC-X, but not for HCQ. Additionally, the study evaluated the bioanalytical data quality and comparability from the various collection methods, as well as patient preference for the devices.
Collapse
Affiliation(s)
| | | | - Xiaoyun Yang
- Genentech, Inc., South San Francisco, California, USA
| | - Ryan Johnson
- Genentech, Inc., South San Francisco, California, USA
| | - Yixuan Zou
- Genentech, Inc., South San Francisco, California, USA
| | - Brian Dean
- Genentech, Inc., South San Francisco, California, USA
| | - Liuxi Chen
- Genentech, Inc., South San Francisco, California, USA
| | - Rucha Sane
- Genentech, Inc., South San Francisco, California, USA
| | | | | | - Mary Simon
- Genentech, Inc., South San Francisco, California, USA
| | | |
Collapse
|
3
|
Shyam R, Sekhar Panda H, Mishra J, Jyoti Panda J, Kour A. Emerging biosensors in Phenylketonuria. Clin Chim Acta 2024; 559:119725. [PMID: 38734223 DOI: 10.1016/j.cca.2024.119725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 05/07/2024] [Accepted: 05/08/2024] [Indexed: 05/13/2024]
Abstract
Phenylketonuria (PKU) is an autosomal recessive metabolic disorder resulting from deficient phenylalanine hydroxylase (PAH) enzyme activity, leading to impaired phenylalanine (Phe) metabolism. This condition can lead to intellectual disability, epilepsy, and behavioural issues. Treatment typically involves strict dietary restrictions on natural protein intake, supplemented with chemically manufactured protein substitutes containing amino acids other than Phe. Various approaches, including casein glycomacropeptide (GMP), tetrahydrobiopterin (BH4), phenylalanine ammonia-lyase (PAL) therapy, large neutral amino acid (LNAA) supplementation, enzyme therapy, gene therapy, and medical therapies, aim to prevent Phe transport in the brain to potentially treat PKU. Although newborn screening programs and early dietary interventions have enhanced outcomes of the potential treatment strategies, limitations still persist in this direction. These involve potent accuracy concerns in diagnosis due to the existence of antibiotics in blood of PKU patients, affecting growth of the bacteria in the bacterial inhibition assay. Monitoring involves complex methods for instance, mass spectrometry and high-pressure liquid chromatography, which involve shortcomings such as lengthy protocols and the need for specialized equipment. To address these limitations, adaptable testing formats like bio/nano sensors are emerging with their cost-effectiveness, biodegradability, and rapid, accurate, and sensitive detection capabilities, offering promising alternatives for PKU diagnosis. This review provides insights into current treatment and diagnostic approaches, emphasizing on the potential applications of the diverse sensors intended for PKU diagnosis.
Collapse
Affiliation(s)
- Ritika Shyam
- University Institute of Pharma Sciences, Chandigarh University, Gharuan, Mohali, Punjab 140413, India
| | | | - Jibanananda Mishra
- School of Biosciences, RIMT University, Mandi Gobindgarh, Punjab 147301, India
| | - Jiban Jyoti Panda
- Institute of Nanoscience and Technology, Mohali, Punjab 140306, India.
| | - Avneet Kour
- University Institute of Pharma Sciences, Chandigarh University, Gharuan, Mohali, Punjab 140413, India.
| |
Collapse
|
4
|
Greaves RF, Kumar M, Mawad N, Francescon A, Le C, O’Connell M, Chi J, Pitt J. Best Practice for Identification of Classical 21-Hydroxylase Deficiency Should Include 21 Deoxycortisol Analysis with Appropriate Isomeric Steroid Separation. Int J Neonatal Screen 2023; 9:58. [PMID: 37873849 PMCID: PMC10594498 DOI: 10.3390/ijns9040058] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 09/18/2023] [Accepted: 10/09/2023] [Indexed: 10/25/2023] Open
Abstract
There are mixed reports on the inclusion and use of 21 deoxycortisol (21DF) as the primary decision marker for classical 21-hydroxylase deficiency. We hypothesize that this may be due to insufficient recognition of the presence and chromatographic separation of isomeric steroids. The aim of this study was to determine the comparative utility of 21DF for screening and diagnosis of CAH due to classical 21-hydroxylase deficiency using a second-tier LC-MS/MS method that included the separation of isomeric steroids to 17OHP and 21DF. For each baby sample, one 3.2 mm dried blood spot was eluted in a methanolic solution containing isotopically matched internal standards. Data were interrogated by univariate and receiver operator characteristic analysis. Steroid profile results were generated for 924 non-CAH baby samples (median gestational age 37 weeks, range 22 to 43 weeks) and 17 babies with 21-hydroxylase deficiency. The ROC curves demonstrated 21DF to have the best sensitivity and specificity for the diagnosis of classical 21-hydroxylase deficiency with an AUC = 1.0. The heatmap showed the very strong correlation (r = 0.83) between 17OHP and 21DF. Our data support 21DF as a robust marker for CAH due to 21-hydroxylase deficiency. We recommend that 21DF be incorporated into routine newborn screening panels as part of the second-tier LC-MS/MS method, follow-up plasma steroid panels, and external quality assurance material.
Collapse
Affiliation(s)
- Ronda F. Greaves
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
- Department of Paediatrics, University of Melbourne, Parkville, VIC 3052, Australia;
| | - Monish Kumar
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
| | - Nazha Mawad
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
| | - Alberto Francescon
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
| | - Chris Le
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
| | - Michele O’Connell
- Department of Paediatrics, University of Melbourne, Parkville, VIC 3052, Australia;
- Department of Endocrinology, The Royal Children’s Hospital, Parkville, VIC 3052, Australia
| | - James Chi
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
| | - James Pitt
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute, Parkville, VIC 3052, Australia; (M.K.); (N.M.); (A.F.); (C.L.); (J.C.); (J.P.)
- Department of Paediatrics, University of Melbourne, Parkville, VIC 3052, Australia;
| |
Collapse
|
5
|
Zacharia A, Makene T, Kinabo C, Ogweno G, Lyamuya F, Ngasala B. Dried urine spot method for detection of Schistosoma mansoni circulating cathodic antigen in resource-limited settings: a proof of concept study. Front Immunol 2023; 14:1216710. [PMID: 37753086 PMCID: PMC10518387 DOI: 10.3389/fimmu.2023.1216710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 08/28/2023] [Indexed: 09/28/2023] Open
Abstract
Background Among the challenges in schistosomiasis surveillance and mapping surveys is the lack of a sensitive diagnostic method especially in low transmission setting. Currently, the WHO recommends the use point-of-care circulating cathodic antigen (Schisto POC-CCA) tests for surveillance and mapping of intestinal schistosomiasis. However, Schisto POC-CCA test has its drawbacks, one of which is the timely availability of test kits. One approach to overcoming this challenge is to develop a low-cost sampling method that allows for the collection and transport of urine specimens even in resource-limited settings. Objective To develop a simple and efficient method for the collection and detection of Schistosoma mansoni (S. mansoni) CCA using urine spotted onto filter paper. Methodology To develop a dried urine spot (DUS) method, various dried matrix extraction parameters were tested and optimized using predesigned steps. The parameters include the size of filter paper (determined by the number of punches), volume of solvents, and type of solvent. Moreover, we optimized the incubation conditions (time and temperature). Urine and stool specimens to conduct the experiments were collected from volunteer fishermen in Mwanza and this project staff. Data were entered into the Microsoft Excel spreadsheet and IBM Statistical Package for the Social Sciences, version 20 for analysis. Results The optimal results were obtained when the procedure was run under the following conditions: Five punches of filter paper containing DUS were dissolved in 150 µl of distilled water and incubated at room temperature for 24 hours in an Eppendorf tube. More than 93% of the assays performed under these conditions produced results that were either comparable to or significantly better than the standard method. Conclusion This study demonstrates the feasibility of collecting urine specimen (DUS) using filter paper and detecting Schistosoma CCA from DUS specimen using the Schisto POC-CCA cassette test.
Collapse
Affiliation(s)
- Abdallah Zacharia
- Department of Parasitology and Medical Entomology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Twilumba Makene
- Department of Parasitology and Medical Entomology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Clemence Kinabo
- Department of Parasitology and Medical Entomology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - George Ogweno
- National Institute for Medical Research, Mwanza, Tanzania
| | - Faraja Lyamuya
- Neglected Tropical Diseases Control Program, Ministry of Health, Dodoma, Tanzania
| | - Billy Ngasala
- Department of Parasitology and Medical Entomology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| |
Collapse
|
6
|
Carling RS, Emmett EC, Moat SJ. Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria. Clin Chim Acta 2022; 535:157-166. [PMID: 35995273 DOI: 10.1016/j.cca.2022.08.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 08/04/2022] [Accepted: 08/04/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Measurement of dried blood spot (DBS) phenylalanine (Phe) is central to the monitoring of patients with phenylketonuria. However, the volume and hematocrit (Hct) of the blood applied to conventional DBS cards significantly affects analytical results. Volumetric blood collection devices are reported to be more accurate, precise and less prone to Hct effects. METHODS Accuracy, imprecision, effect of blood volume and Hct were evaluated for measurement of Phe and tyrosine using three volumetric devices and compared with the conventional PerkinElmer-226 filter-paper collection devices. i.e. conventional DBS cards. Applicability for use in a clinical laboratory was assessed qualitatively. RESULTS Blood volume did not impact on the performance of the volumetric devices; however, significant biases were observed with the conventional DBS card. A higher Hct introduced unacceptable bias for Neoteryx-Mitra and conventional DBS card. All devices had a mean relative standard deviation (RSD) ≤ 4.1 %, except for the Neoteryx-Mitra (≤ 6.2 %). Relative to liquid blood, the mean biases of Phe for the various devices were -5.1 (HemaXis-DB10), -7.8 (Capitainer-qDBS), -12.0 (Neoteryx-Mitra) and -32.6 % (conventional DBS card). CONCLUSIONS Introducing volumetric collection devices will overcome the significant pre-analytical issues associated with conventional DBS collection and improve the biochemical monitoring of patients with PKU.
Collapse
Affiliation(s)
- Rachel S Carling
- GKT School Medical Education, Kings College London, UK; Biochemical Sciences, Viapath, Guys & St Thomas' NHSFT, London, UK.
| | - Erin C Emmett
- Biochemical Sciences, Viapath, Guys & St Thomas' NHSFT, London, UK
| | - Stuart J Moat
- Department of Medical Biochemistry, Immunology & Toxicology, University Hospital Wales, Cardiff, UK; School of Medicine, Cardiff University, University Hospital Wales, Cardiff, UK
| |
Collapse
|
7
|
Groh R, Weiss LM, Börsch-Supan M, Börsch-Supan A. Effects of spot size on biomarker levels of field-collected dried blood spots: A new algorithm for exact dried blood spot size measurement. Am J Hum Biol 2022; 34:e23777. [PMID: 36001479 PMCID: PMC9606603 DOI: 10.1002/ajhb.23777] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 05/24/2022] [Accepted: 06/03/2022] [Indexed: 01/25/2023] Open
Abstract
OBJECTIVES The quality of blood values analyzed from survey-collected dried blood spot (DBS) samples is affected by fieldwork conditions, particularly spot size. We offer an image-based algorithm that accurately measures the area of field-collected DBS and we investigate the impact of spot size on the analyzed blood marker values. METHODS SHARE, a pan-European study, collected 24 000 DBS samples in 12 countries in its sixth wave. Our new algorithm uses photographs of the DBS samples to calculate the number of pixels of the blood-covered area to measure the spot sizes accurately. We ran regression models to examine the association of spot size and seven DBS analytes. We then compared the application of our new spot-size measures to common spot-size estimation. RESULTS Using automated spot-size measurement, we found that spot size has a significant effect on all markers. Smaller spots are associated with lower measured levels, except for HbA1c, for which we observe a negative effect. Our precisely measured spot sizes explain substantially more variance of DBS analytes compared to commonly used spot-size estimation. CONCLUSION The new algorithm accurately measures the size of field-collected DBS in an automated way. This methodology can be applied to surveys even with very large numbers of observations. The measured spot sizes improve the accuracy of conversion formulae that translate blood marker values derived from DBS into venous blood values. The significance of the spot-size effects on biomarkers in DBS should also incentivize the improvement of fieldwork training and monitoring.
Collapse
Affiliation(s)
- Rebecca Groh
- Technical University of Munich, Munich, Germany
- Munich Center for the Economics of Aging at the Max Planck Institute for Social Law and Social Policy, Munich, Germany
| | - Luzia M. Weiss
- Munich Center for the Economics of Aging at the Max Planck Institute for Social Law and Social Policy, Munich, Germany
| | | | - Axel Börsch-Supan
- Technical University of Munich, Munich, Germany
- Munich Center for the Economics of Aging at the Max Planck Institute for Social Law and Social Policy, Munich, Germany
- Survey of Health, Ageing and Retirement in Europe, Munich, Germany
- National Bureau of Economic Research, Cambridge, Massachusetts
| |
Collapse
|
8
|
Role of Paper-Based Sensors in Fight against Cancer for the Developing World. BIOSENSORS 2022; 12:bios12090737. [PMID: 36140122 PMCID: PMC9496559 DOI: 10.3390/bios12090737] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/25/2022] [Accepted: 08/31/2022] [Indexed: 11/17/2022]
Abstract
Cancer is one of the major killers across the globe. According to the WHO, more than 10 million people succumbed to cancer in the year 2020 alone. The early detection of cancer is key to reducing the mortality rate. In low- and medium-income countries, the screening facilities are limited due to a scarcity of resources and equipment. Paper-based microfluidics provide a platform for a low-cost, biodegradable micro-total analysis system (µTAS) that can be used for the detection of critical biomarkers for cancer screening. This work aims to review and provide a perspective on various available paper-based methods for cancer screening. The work includes an overview of paper-based sensors, the analytes that can be detected and the detection, and readout methods used.
Collapse
|
9
|
Kulyk DS, Sahraeian T, Lee S, Badu-Tawiah AK. Microsampling with a Solid-Phase Extraction Cartridge: Storage and Online Mass Spectrometry Analysis. Anal Chem 2021; 93:13632-13640. [PMID: 34590821 DOI: 10.1021/acs.analchem.1c02960] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study aims to introduce the concept of utilizing a solid-phase extraction (SPE) cartridge for remote biofluid collection, followed by direct sample analysis at a later time. For this, a dried matrix spot was prepared in a syringe, in the form of SPE cartridge for the first time to enable small biofluid collection (microsampling), storage, shipment, and online electrospray ionization (ESI) mass spectrometry (MS) analysis of the stored dried samples. The SPE sorbents were packed into an ESI syringe and the resultant cartridge was used for sampling small volumes (<20 μL) of different complex biological fluids including blood, plasma, serum, and urine. The collected sample was stored in the dry state within the confinement of the SPE sorbent at room temperature, and analyte stability (e.g., diazepam) was maintained for more than a year. Direct coupling of the SPE cartridge to MS provides excellent accuracy, precision, and sensitivity for analyzing illicit drugs present in the biofluid. The corresponding mechanism of wrong-way positive ion generation from highly basic elution solvents was explored. Without chromatography, our direct SPE-ESI-MS analysis technique afforded detection limits as low as 26 and 140 pg/mL for raw urine and untreated plasma, respectively. These promising results proved that the new syringe-based SPE cartridge can serve as a good alternative to conventional microsampling techniques in terms of analyte stability, ease of operation and versatility, and analytical sensitivity and speed.
Collapse
Affiliation(s)
- Dmytro S Kulyk
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Taghi Sahraeian
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Suji Lee
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| |
Collapse
|
10
|
Börsch-Supan A, Weiss LM, Börsch-Supan M, Potter AJ, Cofferen J, Kerschner E. Dried blood spot collection, sample quality, and fieldwork conditions: Structural validations for conversion into standard values. Am J Hum Biol 2021; 33:e23517. [PMID: 33063418 PMCID: PMC10980534 DOI: 10.1002/ajhb.23517] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES SHARE, a pan-European panel study in 27 European countries and Israel, has collected dried blood spot (DBS) samples from approximately 27 000 respondents in 13 countries. We aim to obtain factors to convert analyte values between DBS and venous blood samples (VBS) taking account of adverse fieldwork conditions such as small spot size, high temperature and humidity, short drying time and long shipment times. METHODS We obtained VBS and DBS from a set of 20 donors in a laboratory setting, and treated the DBS in a systematic and controlled fashion simulating SHARE fieldwork conditions. We used the 3420 outcomes to estimate from DBS analyte values the values that we would have obtained had it been feasible to collect and analyze the donors' venous blood samples. RESULTS The influence of field conditions and sample quality on DBS analyte values is significant and differs among assays. Varying spot size is the main challenge and affects all markers except HbA1c. Smaller spots lead to overly high measured levels. A missing desiccant is detrimental for all markers except CRP and tHb. The temperature to which the samples are exposed plays a significant role for HDL and CysC, while too brief a drying time affects CRP and CysC. Lab-based adjustment formulae only accounting for the differences between re-liquefied DBS and venous blood do not address these fieldwork conditions. CONCLUSIONS By simulating adverse fieldwork conditions in the lab, we were able to validate DBS collected under such conditions and established conversion formulae with high prediction accuracy.
Collapse
Affiliation(s)
- Axel Börsch-Supan
- Munich Center for the Economics of Aging (MEA) at the Max Planck Institute for Social Law and Social Policy, Munich, Germany
- Department of Economics and Business, Technical University of Munich (TUM), Munich, Germany
- National Bureau of Economic Research (NBER), Cambridge, Massachusetts
| | - Luzia M. Weiss
- Munich Center for the Economics of Aging (MEA) at the Max Planck Institute for Social Law and Social Policy, Munich, Germany
| | - Martina Börsch-Supan
- Survey of Health, Aging and Retirement in Europe (SHARE Biomarker Project), Munich, Germany
| | - Alan J. Potter
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington
| | - Jake Cofferen
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington
| | - Elizabeth Kerschner
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington
| |
Collapse
|
11
|
Zakaria R, Allen KJ, Koplin JJ, Roche P, Greaves RF. Candidate reference method for determination of vitamin D from dried blood spot samples. Clin Chem Lab Med 2021; 58:817-827. [PMID: 31348755 DOI: 10.1515/cclm-2019-0397] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Accepted: 06/12/2019] [Indexed: 11/15/2022]
Abstract
Background The current millennium has seen an explosion in vitamin D testing with the overarching aim of requests to clinically stratify patients as replete or deficient in vitamin D. At a population level, dried blood spot (DBS) sampling offers a less invasive and more practical application for assessment of vitamin D status. We have therefore aimed to develop a sensitive and robust DBS vitamin D method that is traceable to serum for use in population-based studies. Methods Blood spots, calibrators and controls were prepared by punching a 3.2 mm DBS from filter paper and placed into a 96-well micro-plate. The DBS disk was eluted with a combination of water-methanol and internal standard (ISTD) solution followed by supported-liquid extraction and derivatisation. The extract was analysed by liquid-chromatography tandem-mass spectrometry in positive electrospray-ionisation mode with 732.5 > 673.4 and 738.4 > 679.4 m/z ion-transitions for derivatised vitamin D and the ISTD, respectively. Vitamin D results were made traceable to the National Institute of Standards and Technology reference material through the inclusion of Chromsystems vitamin D calibrators. Results 25-Hydroxy-vitamin D3 and its related ISTD were detected at a retention time of 7 min. The seven-point calibration-curve consistently demonstrated a coefficient of determination of 0.99 with an experimentally determined reportable range of 0.5-376 nmol/L. Method validation studies using DBS samples demonstrated 12.9% between-assay imprecision at 45 nmol/L, 84% average recovery and high correlation with plasma vitamin D (correlation coefficient = 0.86). Conclusions We have successfully developed an analytical method for vitamin D quantitation from DBSs which will be applied to our population-based vitamin D research study. This approach improves traceability of DBS results and potentially could be used broadly for other DBS measurands that require comparison to serum/plasma for their interpretation.
Collapse
Affiliation(s)
- Rosita Zakaria
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.,Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Katrina J Allen
- Murdoch Children's Research Institute, Parkville, Victoria, Australia
| | - Jennifer J Koplin
- Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Paediatrics, University of Melbourne, Parkville, Victoria, Australia.,Melbourne School of Population and Global Health, University of Melbourne, Parkville, Victoria, Australia
| | - Peter Roche
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia
| | - Ronda F Greaves
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.,Department of Paediatrics, University of Melbourne, Parkville, Victoria, Australia.,Victorian Clinical Genetics Services, Murdoch Children's Research Institute, Parkville, Victoria 3052, Australia
| |
Collapse
|
12
|
Detection of SARS-CoV-2 IgG antibodies in dried blood spots. Diagn Microbiol Infect Dis 2021; 101:115425. [PMID: 34116343 PMCID: PMC8116316 DOI: 10.1016/j.diagmicrobio.2021.115425] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/14/2021] [Accepted: 04/27/2021] [Indexed: 01/07/2023]
Abstract
The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37°C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.
Collapse
|
13
|
Nybo M, Fruekilde PN, Andersen-Ranberg K. Measurement of vitamin D in dried blood spots stored under different temperature conditions. Ann Clin Biochem 2021; 58:461-467. [PMID: 33874736 DOI: 10.1177/00045632211013870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND As part of the Survey of Health, Ageing and Retirement in Europe (SHARE) study, dried blood spot samples were obtained for measurement of potential biological biomarkers, among those vitamin D. Unfortunately, no studies describe the impact of high temperatures on dried blood spot samples and vitamin D measurements. MATERIALS AND METHODS Capillary samples were collected on dried blood spot cards from 40 outpatients (median age 78 years) along with venous blood samples. To mimic the different environmental and temporal challenges during collection and shipment until final storage in the SHARE study, dried blood spot cards were stored at different temperatures, at time span and with/without freeze-thaw. Vitamin D concentrations in venous plasma samples were measured by conventional immunoassay (on Architect i2000SR), while vitamin D concentrations in dried blood spot samples were measured using LC-MS/MS with a well-described extraction method and with relevant calibration and comparison with a reference method. RESULTS Vitamin D measured in dried blood spot samples did not differ significantly from venous plasma measurements under the different storage conditions tested. The optimal vitamin D correlation between the two matrices was by storage at either 21°C or 35°C for four days (r = 0.9060 and 0.9026, respectively). Freeze-thaw of the dried blood spot samples did not have any significant effect. CONCLUSION We find that vitamin D measured in dried blood spot samples do not differ significantly from venous plasma measurements despite storage at different temperatures and freeze-thaw, which enables the use of dried blood spot in multicentre studies taking place under alternating temperature conditions.
Collapse
Affiliation(s)
- Mads Nybo
- Department of Clinical Biochemistry and Pharmacology, Odense University Hospital, Odense, Denmark
| | - Palle N Fruekilde
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Karen Andersen-Ranberg
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.,Danish Ageing Research Center (DARC), University of Southern Denmark (SDU), Odense, Denmark
| |
Collapse
|
14
|
Barr DB, Kannan K, Cui Y, Merrill L, Petrick LM, Meeker JD, Fennell TR, Faustman EM. The use of dried blood spots for characterizing children's exposure to organic environmental chemicals. ENVIRONMENTAL RESEARCH 2021; 195:110796. [PMID: 33508256 PMCID: PMC7988293 DOI: 10.1016/j.envres.2021.110796] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 01/02/2021] [Accepted: 01/20/2021] [Indexed: 05/05/2023]
Abstract
Biomonitoring is a commonly used tool for exposure assessment of organic environmental chemicals with urine and blood samples being the most commonly used matrices. However, for children's studies, blood samples are often difficult to obtain. Dried blood spots (DBS) represent a potential matrix for blood collection in children that may be used for biomonitoring. DBS are typically collected at birth to screen for several congenital disorders and diseases; many of the states that are required to collect DBS archive these spots for years. If the archived DBS can be accessed by environmental health researchers, they potentially could be analyzed to retrospectively assess exposure in these children. Furthermore, DBS can be collected prospectively in the field from children ranging in age from newborn to school-aged with little concern from parents and minimal risk to the child. Here, we review studies that have evaluated the measurement of organic environmental toxicants in both archived and prospectively collected DBS, and where available, the validation procedures that have been performed to ensure these measurements are comparable to traditional biomonitoring measurements. Among studies thus far, the amount of validation has varied considerably with no studies systematically evaluating all parameters from field collection, shipping and storage contamination and stability to laboratory analysis feasibility. These validation studies are requisite to ensure reliability of the measurement and comparability to more traditional matrices. Thus, we offer some recommendations for validation studies and other considerations before DBS should be adopted as a routine matrix for biomonitoring.
Collapse
Affiliation(s)
- Dana Boyd Barr
- Emory University, Rollins School of Public Health, Gangarosa Department of Environmental Health, Atlanta, GA, USA.
| | - Kurunthachalam Kannan
- Department of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, New York, NY, USA
| | - Yuxia Cui
- National Institute of Environmental Health Sciences, Research Triangle Park, NC, USA
| | | | - Lauren M Petrick
- The Senator Frank R. Lautenberg Environmental Health Sciences Laboratory, Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - John D Meeker
- School of Public Health, University of Michigan, Ann Arbor, MI, USA
| | | | - Elaine M Faustman
- University of Washington, School of Public Health, Department of Environmental and Occupational Health, Seattle, WA, USA
| |
Collapse
|
15
|
Frey BS, Damon DE, Badu-Tawiah AK. Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications. MASS SPECTROMETRY REVIEWS 2020; 39:336-370. [PMID: 31491055 PMCID: PMC7875099 DOI: 10.1002/mas.21601] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/22/2019] [Indexed: 05/20/2023]
Abstract
Recent advancements in the sensitivity of chemical instrumentation have led to increased interest in the use of microsamples for translational and biomedical research. Paper substrates are by far the most widely used media for biofluid collection, and mass spectrometry is the preferred method of analysis of the resultant dried blood spot (DBS) samples. Although there have been a variety of review papers published on DBS, there has been no attempt to unify the century old DBS methodology with modern applications utilizing modified paper and paper-based microfluidics for sampling, storage, processing, and analysis. This critical review will discuss how mass spectrometry has expanded the utility of paper substrates from sample collection and storage, to direct complex mixture analysis to on-surface reaction monitoring.
Collapse
Affiliation(s)
- Benjamin S Frey
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| | - Deidre E Damon
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| |
Collapse
|
16
|
Moat SJ, George RS, Carling RS. Use of Dried Blood Spot Specimens to Monitor Patients with Inherited Metabolic Disorders. Int J Neonatal Screen 2020; 6:26. [PMID: 33073023 PMCID: PMC7422991 DOI: 10.3390/ijns6020026] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 03/08/2020] [Indexed: 12/26/2022] Open
Abstract
Monitoring of patients with inherited metabolic disorders (IMDs) using dried blood spot (DBS) specimens has been routinely used since the inception of newborn screening (NBS) for phenylketonuria in the 1960s. The introduction of flow injection analysis tandem mass spectrometry (FIA-MS/MS) in the 1990s facilitated the expansion of NBS for IMDs. This has led to increased identification of patients who require biochemical monitoring. Monitoring of IMD patients using DBS specimens is widely favoured due to the convenience of collecting blood from a finger prick onto filter paper devices in the patient's home, which can then be mailed directly to the laboratory. Ideally, analytical methodologies with a short analysis time and high sample throughput are required to enable results to be communicated to patients in a timely manner, allowing prompt therapy adjustment. The development of ultra-performance liquid chromatography (UPLC-MS/MS), means that metabolic laboratories now have the capability to routinely analyse DBS specimens with superior specificity and sensitivity. This advancement in analytical technology has led to the development of numerous assays to detect analytes at low concentrations (pmol/L) in DBS specimens that can be used to monitor IMD patients. In this review, we discuss the pre-analytical, analytical and post-analytical variables that may affect the final test result obtained using DBS specimens used for monitoring of patients with an IMD.
Collapse
Affiliation(s)
- Stuart J. Moat
- Department of Medical Biochemistry, Immunology & Toxicology, University Hospital of Wales, Cardiff CF14 4XW, UK
- School of Medicine, Cardiff University, University Hospital Wales, Cardiff CF14 4XW, UK
| | - Roanna S. George
- Derriford Combined Laboratory, University Hospitals Plymouth NHS Trust, Plymouth PL6 8DH, UK;
| | - Rachel S. Carling
- Biochemical Sciences, Viapath, Guys & St Thomas’ NHSFT, London SE1 7EH, UK;
- GKT School of Medical Education, King’s College, London SE1 1UH, UK
| |
Collapse
|
17
|
Abstract
PURPOSE OF REVIEW Exposomics studies can measure health-relevant chemical exposures during a lifetime and estimate the 'internal' environment. However, sampling limitations make these features difficult to capture directly during the critical neonatal time period. RECENT FINDINGS We review the use of newborn dried bloodspots (DBS) archived from newborn screening programs for exposomic analysis in epidemiological children's health studies. Emerging 'omics technologies such as adductomics and metabolomics have been adapted for DBS analysis, and these technologies can now provide valuable etiological information on the complex interplay between exposures, biological response, and population phenotypes. SUMMARY Adductomics and metabolomics of DBS can provide robust measurements for retrospective epidemiological investigations. With extensive bioarchiving programs in the United States and other countries, DBS are poised to substantially aid epidemiological studies, particularly for rare and low-frequency childhood diseases and disorders.
Collapse
|
18
|
Official International Association for Therapeutic Drug Monitoring and Clinical Toxicology Guideline: Development and Validation of Dried Blood Spot-Based Methods for Therapeutic Drug Monitoring. Ther Drug Monit 2020; 41:409-430. [PMID: 31268966 DOI: 10.1097/ftd.0000000000000643] [Citation(s) in RCA: 214] [Impact Index Per Article: 42.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Dried blood spot (DBS) analysis has been introduced more and more into clinical practice to facilitate Therapeutic Drug Monitoring (TDM). To assure the quality of bioanalytical methods, the design, development and validation needs to fit the intended use. Current validation requirements, described in guidelines for traditional matrices (blood, plasma, serum), do not cover all necessary aspects of method development, analytical- and clinical validation of DBS assays for TDM. Therefore, this guideline provides parameters required for the validation of quantitative determination of small molecule drugs in DBS using chromatographic methods, and to provide advice on how these can be assessed. In addition, guidance is given on the application of validated methods in a routine context. First, considerations for the method development stage are described covering sample collection procedure, type of filter paper and punch size, sample volume, drying and storage, internal standard incorporation, type of blood used, sample preparation and prevalidation. Second, common parameters regarding analytical validation are described in context of DBS analysis with the addition of DBS-specific parameters, such as volume-, volcano- and hematocrit effects. Third, clinical validation studies are described, including number of clinical samples and patients, comparison of DBS with venous blood, statistical methods and interpretation, spot quality, sampling procedure, duplicates, outliers, automated analysis methods and quality control programs. Lastly, cross-validation is discussed, covering changes made to existing sampling- and analysis methods. This guideline of the International Association of Therapeutic Drug Monitoring and Clinical Toxicology on the development, validation and evaluation of DBS-based methods for the purpose of TDM aims to contribute to high-quality micro sampling methods used in clinical practice.
Collapse
|
19
|
Moat SJ, Schulenburg-Brand D, Lemonde H, Bonham JR, Weykamp CW, Mei JV, Shortland GS, Carling RS. Performance of laboratory tests used to measure blood phenylalanine for the monitoring of patients with phenylketonuria. J Inherit Metab Dis 2020; 43:179-188. [PMID: 31433494 PMCID: PMC7957320 DOI: 10.1002/jimd.12163] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 08/16/2019] [Accepted: 08/19/2019] [Indexed: 01/16/2023]
Abstract
Analysis of blood phenylalanine is central to the monitoring of patients with phenylketonuria (PKU) and age-related phenylalanine target treatment-ranges (0-12 years; 120-360 μmol/L, and >12 years; 120-600 μmol/L) are recommended in order to prevent adverse neurological outcomes. These target treatment-ranges are based upon plasma phenylalanine concentrations. However, patients are routinely monitored using dried bloodspot (DBS) specimens due to the convenience of collection. Significant differences exist between phenylalanine concentrations in plasma and DBS, with phenylalanine concentrations in DBS specimens analyzed by flow-injection analysis tandem mass spectrometry reported to be 18% to 28% lower than paired plasma concentrations analyzed using ion-exchange chromatography. DBS specimens with phenylalanine concentrations of 360 and 600 μmol/L, at the critical upper-target treatment-range thresholds would be plasma equivalents of 461 and 768 μmol/L, respectively, when a reported difference of 28% is taken into account. Furthermore, analytical test imprecision and bias in conjunction with pre-analytical factors such as volume and quality of blood applied to filter paper collection devices to produce DBS specimens affect the final test results. Reporting of inaccurate patient results when comparing DBS results to target treatment-ranges based on plasma concentrations, together with inter-laboratory imprecision could have a significant impact on patient management resulting in inappropriate dietary change and potentially adverse patient outcomes. This review is intended to provide perspective on the issues related to the measurement of phenylalanine in blood specimens and to provide direction for the future needs of PKU patients to ensure reliable monitoring of metabolic control using the target treatment-ranges.
Collapse
Affiliation(s)
- Stuart J. Moat
- Department of Medical Biochemistry, Immunology & Toxicology, University Hospital Wales, Cardiff, UK
- School of Medicine, Cardiff University, University Hospital Wales, Cardiff, UK
| | - Danja Schulenburg-Brand
- Department of Medical Biochemistry, Immunology & Toxicology, University Hospital Wales, Cardiff, UK
| | - Hugh Lemonde
- Paediatric Metabolic Medicine, Evelina Children’s Hospital, Guys & St Thomas’ NHSFT, London, UK
| | - James R. Bonham
- Department of Clinical Chemistry, Sheffield Children’s (NHS) FT, Sheffield, UK
| | - Cas W. Weykamp
- MCA Laboratory, Queen Beatrix Hospital, Winterswijk, The Netherlands
| | - Joanne V. Mei
- Newborn Screening and Molecular Biology Branch, Centers for Disease Control and Prevention, Atlanta, Georgia
| | | | - Rachel S. Carling
- Biochemical Sciences, Viapath, Guys & St Thomas’ NHSFT, London, UK
- GKT School of Medical Education, King’s College, London, UK
| |
Collapse
|
20
|
Effect of blood volume on analytical bias in dried blood spots prepared for newborn screening external quality assurance. Bioanalysis 2020; 12:99-109. [DOI: 10.4155/bio-2019-0201] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: Dried blood spots (DBS) are used for the analysis of more than 2000 biomarkers. We assessed a range of analyte concentrations and diameters of DBS. Materials & methods: DBS samples were created by the application of increasing volumes of whole blood prepared by the UK NEQAS Quality Assurance Laboratory. Samples were analyzed in four separate laboratories. Results: Volumes less than 25 μl (8 mm) and more than 75 μl (14 mm) created unsatisfactory analytical biases. Results obtained from peripheral subpunches tended to be higher than those from a central subpunch. Conclusion: DBS diameters formed from nonvolumetric application of blood to filter paper can be used to assess whether measurement bias will be within acceptable limits according to the analyte being quantified. DBS received for newborn screening in the UK with diameters less than 8 mm and those more than 14 mm should be rejected.
Collapse
|
21
|
Moretti M, Freni F, Valentini B, Vignali C, Groppi A, Visonà SD, Osculati AMM, Morini L. Determination of Antidepressants and Antipsychotics in Dried Blood Spots (DBSs) Collected from Post-Mortem Samples and Evaluation of the Stability over a Three-Month Period. Molecules 2019; 24:molecules24203636. [PMID: 31600953 PMCID: PMC6832719 DOI: 10.3390/molecules24203636] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 10/04/2019] [Accepted: 10/06/2019] [Indexed: 01/17/2023] Open
Abstract
An LC-MS/MS method for the identification and quantification of antidepressants and antipsychotics was developed on dried blood spots (DBSs). Moreover, analyte stability on DBSs within a 3-month period was monitored. Aliquots of 85 µL of blood from autopsy cases were pipetted onto DBS cards, which were dried and stored at room temperature. DBSs were analyzed in triplicate immediately, within the following 3 weeks, and after 3 months. For each analysis, a whole blood stain was extracted in phosphate buffer and purified using Solid Phase Extraction (SPE) cartridges in order to avoid matrix effects and injected in the LC-MS/MS system. Thirty-nine molecules were screened. Limits of detection (LODs) ranged between 0.1 and 3.2 ng/mL (g) and 0.1 and 5.2 ng/mL (g) for antidepressants and antipsychotics, respectively. Limits of quantification (LOQs) varied from 5 to 10.0 ng/mL for both. Sixteen cases among the 60 analyzed resulted positive for 17 different analytes; for 14 of these the method was fully validated. A general good agreement between the concentrations on DBSs and those measured in conventional blood samples (collected concurrently and stored at -20 °C) was observed. The degradation/enhancement percentage for most of the substances was lower than 20% within the 3-month period. Our results, obtained from real post-mortem cases, suggest that DBSs can be used for routine sample storage.
Collapse
Affiliation(s)
- Matteo Moretti
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Francesca Freni
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Beatrice Valentini
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Claudia Vignali
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Angelo Groppi
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Silvia Damiana Visonà
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Antonio Marco Maria Osculati
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| | - Luca Morini
- Department of Public Health, Experimental and Forensic Medicine, University of Pavia, via Forlanini 12, 27100 Pavia, Italy.
| |
Collapse
|
22
|
Comparison between different methods of DNA isolation from dried blood spots for determination of malaria to determine specificity and cost effectiveness. J Parasit Dis 2019; 43:337-342. [PMID: 31406397 DOI: 10.1007/s12639-019-01136-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Accepted: 06/18/2019] [Indexed: 01/17/2023] Open
Abstract
DNA extraction from filter paper by using different methods was compiled through a thorough review of many research articles published in various journals. When performing malaria epidemiological surveys in remote area, it is difficult to collect blood samples and transport it. In field particularly in remote area where facilities for storing and processing of samples does not exist, there surveillance and diagnosis of malaria is very difficult. In this review we are focused upon four simple methods of DNA isolation from the field collected blood and mosquito abdomen blood meal spotted on Whatman No. 1 or No. 3 filter paper. The main DNA isolation methods are Chelex-100, Tris-EDTA (TE) buffer; Methanol based DNA extraction and Phosphate buffer saline (PBS) using Lysis buffer and Phenol-Chloroform method. Efforts have been taken to identify the methods which are cost-effective and take less time to extract DNA from dried blood spots (DBS) and whole mosquitoes. The purpose of this paper is to update the knowledge and find a method to extract DNA from DBS which will be specific, rapid, cost-effective, less time consuming and feasible for epidemiological survey in remote area.
Collapse
|
23
|
Therapeutic Drug Monitoring of Tacrolimus-Personalized Therapy: Second Consensus Report. Ther Drug Monit 2019; 41:261-307. [DOI: 10.1097/ftd.0000000000000640] [Citation(s) in RCA: 227] [Impact Index Per Article: 37.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
24
|
Brunet M, van Gelder T, Åsberg A, Haufroid V, Hesselink DA, Langman L, Lemaitre F, Marquet P, Seger C, Shipkova M, Vinks A, Wallemacq P, Wieland E, Woillard JB, Barten MJ, Budde K, Colom H, Dieterlen MT, Elens L, Johnson-Davis KL, Kunicki PK, MacPhee I, Masuda S, Mathew BS, Millán O, Mizuno T, Moes DJAR, Monchaud C, Noceti O, Pawinski T, Picard N, van Schaik R, Sommerer C, Vethe NT, de Winter B, Christians U, Bergan S. Therapeutic Drug Monitoring of Tacrolimus-Personalized Therapy: Second Consensus Report. Ther Drug Monit 2019. [DOI: 10.1097/ftd.0000000000000640
expr 845143713 + 809233716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
|
25
|
Zakaria R, Allen KJ, Koplin JJ, Crinis N, De Rosa L, Roche P, Greaves RF. Determination of haemoglobin derivatives in aged dried blood spot to estimate haematocrit. ACTA ACUST UNITED AC 2019; 57:1026-1034. [DOI: 10.1515/cclm-2018-0753] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Accepted: 12/04/2018] [Indexed: 12/18/2022]
Abstract
Abstract
Introduction
Dried blood spot (DBS) sample applications now encompass analytes related to clinical diagnosis, epidemiological studies, therapeutic drug monitoring, pharmacokinetic and toxicokinetic studies. Haematocrit (Hct) and haemoglobin (Hb) at very high or low concentrations may influence the accuracy of measurement quantification of the DBS sample. In this study, we aimed to predict the Hct of the punched DBS through primary spectrophotometric estimation of its haemoglobin-derivative (Hb-drv) content.
Methods
Formic acid solution was used to elute Hb-drv content of 3.2 mm spotted blood from its dry matrix. Direct spectrometry measurement was utilised to scan the extracted Hb-drv in the visible spectrum range of 520–600 nm. The linear relationship between an individual’s Hct percentage and Hb-drv concentration was applied to estimate the Hct level of the blood spot. De-identified whole blood samples were used for the method development and evaluation studies.
Results
The Hb-drv estimation is valid in samples >2 months old. Method validation experiments DBS demonstrate linearity between 82.5 and 207.5 g/L, average coefficient of variation of 3.6% (intra-assay) and 7.7% (inter-assay), analytical recovery of 84%, and a high positive correlation (r=0.88) between Hb-drv and the original whole blood Hct. The Bland-Altman difference plot demonstrates a mean difference of 2.4% between the calculated DBS Hct and the directly measured Hct from fresh whole bloods.
Conclusions
We have successfully developed a simple Hb-drv method to estimate Hct in aged DBS samples. This method can be incorporated into DBS analytical work-flow for the in-situ estimation of Hct and subsequent correction of the analyte of interest as required.
Collapse
Affiliation(s)
- Rosita Zakaria
- School of Health and Biomedical Sciences , RMIT University , Bundoora, Victoria , Australia
- Murdoch Children’s Research Institute , Parkville, Victoria , Australia
| | - Katrina J. Allen
- Murdoch Children’s Research Institute , Parkville, Victoria , Australia
- Department of Paediatrics , University of Melbourne , Parkville, Victoria , Australia
- Department of Allergy and Clinical Immunology , Royal Children’s Hospital , Parkville, Victoria , Australia
| | | | - Nick Crinis
- Clinical Biochemistry, Austin Pathology , Heidelberg, Victoria , Australia
| | - Lidia De Rosa
- Core Laboratory, Pathology , The Royal Children’s Hospital , Parkville, Victoria , Australia
| | - Peter Roche
- School of Health and Biomedical Sciences , RMIT University , Bundoora, Victoria , Australia
| | - Ronda F. Greaves
- School of Health and Biomedical Sciences , RMIT University , Bundoora, Victoria , Australia
- Victorian Clinical Genetics Services, Murdoch Children’s Research Institute , Flemington Rd , Parkville, Victoria 3052 , Australia
| |
Collapse
|
26
|
Damon DE, Yin M, Allen DM, Maher YS, Tanny CJ, Oyola-Reynoso S, Smith BL, Maher S, Thuo MM, Badu-Tawiah AK. Dried Blood Spheroids for Dry-State Room Temperature Stabilization of Microliter Blood Samples. Anal Chem 2018; 90:9353-9358. [DOI: 10.1021/acs.analchem.8b01962] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Deidre E. Damon
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Mengzhen Yin
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Danyelle M. Allen
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Yosef S. Maher
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Christian J. Tanny
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Stephanie Oyola-Reynoso
- Department of Materials Science and Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Barry L. Smith
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, U.K. L69 3GJ
| | - Simon Maher
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, U.K. L69 3GJ
| | - Martin M. Thuo
- Department of Materials Science and Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| |
Collapse
|
27
|
Dried matrix spots and clinical elemental analysis. Current status, difficulties, and opportunities. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.12.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
28
|
Use of Blood-soaked Cellulose Filter Paper for Measuring Carbon and Nitrogen Stable Isotopes. J Wildl Dis 2018; 54:375-379. [PMID: 29369725 DOI: 10.7589/2017-08-202] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We explored the use of filter paper soaked in whole blood for measuring carbon (C) and nitrogen (N) stable isotopes, often used in feeding ecology or diet studies, to better understand drivers of exposure to contaminants. Our results showed no statistically or biologically relevant differences in C and N stable isotope measures between our gold standard (whole blood with anticoagulant) and eluates from processed, blood-soaked filter paper. Our data supported the effectiveness of using filter paper for assessing C and N stable isotopes in blood to address feeding ecology and other uses. The ease of sampling and processing should allow blood-soaked filter paper to be used in sampling of live (e.g., captured, stranded) and lethally taken (e.g., hunter-killed) wild vertebrates.
Collapse
|
29
|
Barco S, Castagnola E, Moscatelli A, Rudge J, Tripodi G, Cangemi G. Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot. J Pharm Biomed Anal 2017; 145:704-710. [DOI: 10.1016/j.jpba.2017.07.033] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 07/26/2017] [Accepted: 07/27/2017] [Indexed: 12/01/2022]
|
30
|
Wagner M, Tonoli D, Varesio E, Hopfgartner G. The use of mass spectrometry to analyze dried blood spots. MASS SPECTROMETRY REVIEWS 2016; 35:361-438. [PMID: 25252132 DOI: 10.1002/mas.21441] [Citation(s) in RCA: 162] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided.
Collapse
Affiliation(s)
- Michel Wagner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - David Tonoli
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Emmanuel Varesio
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Gérard Hopfgartner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| |
Collapse
|
31
|
The performance of five different dried blood spot cards for the analysis of six immunosuppressants. Bioanalysis 2016; 7:1225-35. [PMID: 26045003 DOI: 10.4155/bio.15.63] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND The relation between hematocrit, substance concentration, extraction recovery and spot formation of tacrolimus, sirolimus, everolimus, ascomycin, temsirolimus and cyclosporin A was investigated for Whatman 31 ET CHR, Whatman FTA DMPK-C, Whatman 903, Perkin Elmer 226 and Agilent Bond Elut DMS DBS cards. RESULTS & DISCUSSION We found that all DBS cards showed the same hematocrit and concentration-dependent recovery patterns for sirolimus, everolimus and temsirolimus. At high concentrations, the total hematocrit effects were much more pronounced than at low concentrations for tacrolimus, sirolimus, everolimus, ascomycin and temsirolimus. CONCLUSION The tested card types showed differences in performance, especially at extreme concentrations and hematocrit values. It may be useful to investigate the performance of different types of DBS cards prior to analytical method validation.
Collapse
|
32
|
Chace DH, Hannon WH. Filter Paper as a Blood Sample Collection Device for Newborn Screening. Clin Chem 2016; 62:423-5. [PMID: 26797689 DOI: 10.1373/clinchem.2015.252007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 12/18/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Donald H Chace
- Pediatrix Analytical, Centers for Research, Education and Quality, Sunrise, FL;
| | - William H Hannon
- Independent consultant, CDC Foundation, and Retired from Newborn Screening Branch, CDC, Atlanta, GA
| |
Collapse
|
33
|
Caudron E, Prognon P, Germain DP. Enzymatic diagnosis of Fabry disease using a fluorometric assay on dried blood spots: An alternative methodology. Eur J Med Genet 2015; 58:681-4. [PMID: 26520229 DOI: 10.1016/j.ejmg.2015.10.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2013] [Revised: 10/17/2015] [Accepted: 10/24/2015] [Indexed: 11/27/2022]
Abstract
Fabry disease (FD, OMIM#301500) is an X-linked lysosomal storage disorder caused by the functional deficiency of α-galactosidase A, a lysosomal enzyme. A method to screen for FD in large populations has been developed using a fluorometric assay of α-galactosidase A activity in dried blood spots (DBS) on filter paper. However, results can be influenced by quenching of fluorescence by haemoglobin which, together with small sample size, may result in a low light emission signal. An alternative, simple and sensitive fluorometric assay was developed for the determination of α-galactosidase A activity in DBS. The assay uses 4-methylumbelliferyl-α-d-galactose as an artificial substrate. To minimize the risk of false-positives, zinc sulfate was used for protein precipitation to stop the enzymatic reaction and eliminate interfering species (hemoglobin). Samples from 209 individuals (60 hemizygotes, 68 heterozygotes, and 81 controls) were tested to establish reference values for the assay. The mean α-galactosidase A activity of the 81 controls was 9.1 ± 3.3 μmol h(-1) L(-1) (mean ± SD). All 60 hemizygotes affected with FD had AGAL activities below 1.7 μmol h(-1) L(-1) (0.2 ± 0.3 μmol h(-1) L(-1)). For the 68 heterozygous females, AGAL activity ranged from 0 to 12.6 μmol h(-1) L(-1) (3.5 ± 2.7 μmol h(-1) L(-1)). Two-thirds of the female patients could be identified using the enzymatic assay and a cut-off level of 40% of the median control value (<3.4 μmol h(-1) L(-1)). Our fluorometric assay using zinc sulfate protein precipitation was shown to have similar sensitivity and robustness while reducing the risk of false positive results due to quenching of 4-MU fluorescence by haemoglobin.
Collapse
Affiliation(s)
- Eric Caudron
- Department of Pharmacy, AP-HP, Hôpital Européen Georges Pompidou, Paris, France
| | - Patrice Prognon
- Department of Pharmacy, AP-HP, Hôpital Européen Georges Pompidou, Paris, France
| | - Dominique P Germain
- University of Versailles - St Quentin en Yvelines (UVSQ), Division of Medical Genetics, Montigny, France.
| |
Collapse
|
34
|
Grüner N, Stambouli O, Ross RS. Dried blood spots--preparing and processing for use in immunoassays and in molecular techniques. J Vis Exp 2015:52619. [PMID: 25867233 PMCID: PMC4397000 DOI: 10.3791/52619] [Citation(s) in RCA: 86] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
The idea of collecting blood on a paper card and subsequently using the dried blood spots (DBS) for diagnostic purposes originated a century ago. Since then, DBS testing for decades has remained predominantly focused on the diagnosis of infectious diseases especially in resource-limited settings or the systematic screening of newborns for inherited metabolic disorders and only recently have a variety of new and innovative DBS applications begun to emerge. For many years, pre-analytical variables were only inappropriately considered in the field of DBS testing and even today, with the exception of newborn screening, the entire pre-analytical phase, which comprises the preparation and processing of DBS for their final analysis has not been standardized. Given this background, a comprehensive step-by-step protocol, which covers al the essential phases, is proposed, i.e., collection of blood; preparation of blood spots; drying of blood spots; storage and transportation of DBS; elution of DBS, and finally analyses of DBS eluates. The effectiveness of this protocol was first evaluated with 1,762 coupled serum/DBS pairs for detecting markers of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus infections on an automated analytical platform. In a second step, the protocol was utilized during a pilot study, which was conducted on active drug users in the German cities of Berlin and Essen.
Collapse
Affiliation(s)
- Nico Grüner
- Institute of Virology, National Reference Centre for Hepatitis C, Essen University Hospital, University of Duisburg-Essen
| | - Oumaima Stambouli
- Institute of Virology, National Reference Centre for Hepatitis C, Essen University Hospital, University of Duisburg-Essen
| | - R Stefan Ross
- Institute of Virology, National Reference Centre for Hepatitis C, Essen University Hospital, University of Duisburg-Essen;
| |
Collapse
|
35
|
Assessment of the within- and between-lot variability of Whatman™ FTA(®) DMPK and 903(®) DBS papers and their suitability for the quantitative bioanalysis of small molecules. Bioanalysis 2014; 5:2613-30. [PMID: 24180503 DOI: 10.4155/bio.13.227] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
BACKGROUND To ensure that PK data generated from DBS samples are of the highest quality, it is important that the paper substrate is uniform and does not unduly contribute to variability. This study investigated any within and between lot variations for four cellulose paper types: Whatman™ FTA(®) DMPK-A, -B and -C, and 903(®) (GE Healthcare, Buckinghamshire, UK). The substrates were tested to demonstrate manufacturing reproducibility (thickness, weight, chemical coating concentration) and its effect on the size of the DBS produced, and the quantitative data derived from the bioanalysis of human DBS samples containing six compounds of varying physicochemical properties. RESULTS & DISCUSSION Within and between lot variations in paper thickness, mass and chemical coating concentration were within acceptable manufacturing limits. No variation in the spot size or bioanalytical data was observed. CONCLUSION Bioanalytical results obtained for DBS samples containing a number of analytes spanning a range of chemical space are not affected by the lot used or by the location within a lot.
Collapse
|
36
|
de Bruin E, Loeber JG, Meijer A, Castillo GM, Cepeda MLG, Torres-Sepúlveda MR, Borrajo GJC, Caggana M, Giguere Y, Meyer M, Fukushi M, Devi ARR, Khneisser I, Vilarinho L, von Döbeln U, Torresani T, Mackenzie J, Zutt I, Schipper M, Elvers LH, Koopmans MPG. Evolution of an influenza pandemic in 13 countries from 5 continents monitored by protein microarray from neonatal screening bloodspots. J Clin Virol 2014; 61:74-80. [PMID: 25017954 DOI: 10.1016/j.jcv.2014.06.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 06/17/2014] [Accepted: 06/20/2014] [Indexed: 01/15/2023]
Abstract
BACKGROUND Because of lack of worldwide standardization of influenza virus surveillance, comparison between countries of impact of a pandemic is challenging. For that, other approaches to allow internationally comparative serosurveys are welcome. OBJECTIVES Here we explore the use of neonatal screening dried blood spots to monitor the trends of the 2009 influenza A (H1N1) pdm virus by the use of a protein microarray. STUDY DESIGN We contacted colleagues from neonatal screening laboratories and asked for their willingness to participate in a study by testing anonymized neonatal screening bloodspots collected during the course of the pandemic. In total, 7749 dried blood spots from 13 countries in 5 continents where analyzed by using a protein microarray containing HA1 recombinant proteins derived from pandemic influenza A (H1N1) 2009 as well as seasonal influenza viruses. RESULTS Results confirm the early start of the pandemic with extensive circulation in the US and Canada, when circulation of the new virus was limited in other parts of the world. The data collected from sites in Mexico suggested limited circulation of the virus during the early pandemic phase in this country. In contrast and to our surprise, an increase in seroprevalence early in 2009 was noted in the dataset from Argentina, suggestive of much more widespread circulation of the novel virus in this country than in Mexico. CONCLUSIONS We conclude that this uniform serological testing of samples from a highly standardized screening system offers an interesting opportunity for monitoring population level attack rates of widespread diseases outbreaks and pandemics.
Collapse
Affiliation(s)
- E de Bruin
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands.
| | - J G Loeber
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands
| | - A Meijer
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands
| | - G Martinez Castillo
- Unidad de Genetica, Hospital Espanol, Centro de Estudios Neonatales y Geneticos, Mexico State, Mexico
| | | | | | - G J C Borrajo
- Fundación Bioquímica Argentina, Programa de Detección de Errores Congénitos, La Plata, Argentina
| | - M Caggana
- New York State Department of Health, Biggs Laboratory, Albany, USA
| | - Y Giguere
- Programme Québécois de Dépistage Néonatal Sanguin, CHU de Québec, Québec, Canada
| | - M Meyer
- North West University, Potchefstroom Campus, Potchefstroom, South Africa
| | - M Fukushi
- Sapporo City Institute of Public Health, Sapporo, Japan
| | | | - I Khneisser
- Neonatal Screening Laboratory, Medical Genetic Unit, Saint Joseph University, Beirut, Lebanon
| | - L Vilarinho
- Neonatal Screening Unit, Genetics Department, National Institute of Health Dr Ricardo Jorge, Porto, Portugal
| | - U von Döbeln
- Karolinska University Hospital Huddinge, Centre for Inherited Metabolic Disease, Stockholm, Sweden
| | - T Torresani
- Universitäts Kinderklinik, Zürich, Switzerland
| | - J Mackenzie
- Yorkhill Hospital, Scottish Newborn Screening Laboratory, Glasgow, United Kingdom
| | - I Zutt
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands
| | - M Schipper
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands
| | - L H Elvers
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands
| | - M P G Koopmans
- Laboratory for Infectious Diseases and Perinatal Screening, Center for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands; Department of Virology, Erasmus Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
37
|
Smit PW, Elliott I, Peeling RW, Mabey D, Newton PN. An overview of the clinical use of filter paper in the diagnosis of tropical diseases. Am J Trop Med Hyg 2014; 90:195-210. [PMID: 24366501 PMCID: PMC3919219 DOI: 10.4269/ajtmh.13-0463] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Accepted: 11/04/2013] [Indexed: 12/16/2022] Open
Abstract
Tropical infectious diseases diagnosis and surveillance are often hampered by difficulties of sample collection and transportation. Filter paper potentially provides a useful medium to help overcome such problems. We reviewed the literature on the use of filter paper, focusing on the evaluation of nucleic acid and serological assays for diagnosis of infectious diseases using dried blood spots (DBS) compared with recognized gold standards. We reviewed 296 eligible studies and included 101 studies evaluating DBS and 192 studies on other aspects of filter paper use. We also discuss the use of filter paper with other body fluids and for tropical veterinary medicine. In general, DBS perform with sensitivities and specificities similar or only slightly inferior to gold standard sample types. However, important problems were revealed with the uncritical use of DBS, inappropriate statistical analysis, and lack of standardized methodology. DBS have great potential to empower healthcare workers by making laboratory-based diagnostic tests more readily accessible, but additional and more rigorous research is needed.
Collapse
Affiliation(s)
- Pieter W. Smit
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| | - Ivo Elliott
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| | | | | | - Paul N. Newton
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands; London School of Hygiene and Tropical Medicine, London, United Kingdom; Lao-Oxford-Mahosot Hospital–Wellcome Trust Research Unit, Microbiology Laboratory, Mahosot Hospital, Vientiane, Lao People's Democratic Republic; Department of Infectious Diseases, Nottingham University Hospitals National Health Service Trust, Nottingham, United Kingdom; Centre for Tropical Medicine, Nuffield Department of Medicine, Churchill Hospital, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
38
|
State-of-the-art dried blood spot analysis: an overview of recent advances and future trends. Bioanalysis 2013; 5:2187-208. [DOI: 10.4155/bio.13.175] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Dried blood spots have become a popular method in a variety of micro blood-sampling techniques in the life sciences sector, consequently competing with the field of conventional, invasive blood sampling by venepuncture. Dried blood spots are widely applied in numerous bioanalytical assays and have gained a significant role in the screening of inherited metabolic diseases, in PK and PD modeling; in the treatment and diagnosis of infectious diseases; and in therapeutic drug monitoring. Recent technological developments such as automation, online extraction, mass spectrometric direct analysis and also conventional dried blood spot bioanalysis, as well as future developments in dried blood spot bioanalysis are highlighted and presented in this article.
Collapse
|
39
|
Affiliation(s)
- Plamen A. Demirev
- Johns Hopkins University Applied Physics Laboratory, Laurel,
Maryland 20723, United States
| |
Collapse
|
40
|
Aramendía M, Rello L, Vanhaecke F, Resano M. Direct Trace-Elemental Analysis of Urine Samples by Laser Ablation-Inductively Coupled Plasma Mass Spectrometry after Sample Deposition on Clinical Filter Papers. Anal Chem 2012; 84:8682-90. [DOI: 10.1021/ac3018839] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- Maite Aramendía
- Centro Universitario de la Defensa-Academia General Militar de Zaragoza,
Carretera de Huesca s/n, 50090, Zaragoza, Spain
| | - Luis Rello
- Department of Clinical Biochemistry, “Miguel Servet” Universitary Hospital, Paseo Isabel La Católica 1-3, 50009 Zaragoza, Spain
- Department of Analytical Chemistry, University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza,
Spain
| | - Frank Vanhaecke
- Department of Analytical Chemistry, Ghent University, Krijgslaan 281-S12, 9000 Ghent, Belgium
| | - Martín Resano
- Department of Analytical Chemistry, University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza,
Spain
| |
Collapse
|
41
|
Aabye MG, Eugen-Olsen J, Werlinrud AM, Holm LL, Tuuminen T, Ravn P, Ruhwald M. A simple method to quantitate IP-10 in dried blood and plasma spots. PLoS One 2012; 7:e39228. [PMID: 22761744 PMCID: PMC3384664 DOI: 10.1371/journal.pone.0039228] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2012] [Accepted: 05/17/2012] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. AIM To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. METHOD We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. RESULTS The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5-600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37 °C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r(2)>0.97). CONCLUSIONS This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection.
Collapse
Affiliation(s)
- Martine G. Aabye
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Denmark
| | - Jesper Eugen-Olsen
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Denmark
| | - Anne Marie Werlinrud
- Department of Internal Medicine, Infectious Diseases Unit, Herlev University Hospital, Copenhagen, Denmark
| | - Line Lindebo Holm
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Denmark
| | - Tamara Tuuminen
- Department of Bacteriology and Immunology, Haartman Institute, University of Helsinki, Helsinki, Finland
| | - Pernille Ravn
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Denmark
- Department of Infectious Diseases, Odense University Hospital, Odense, Denmark
| | - Morten Ruhwald
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Denmark
- * E-mail:
| |
Collapse
|
42
|
Ruhwald M, Aabye MG, Ravn P. IP-10 release assays in the diagnosis of tuberculosis infection: current status and future directions. Expert Rev Mol Diagn 2012; 12:175-87. [PMID: 22369377 DOI: 10.1586/erm.11.97] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The current state-of-the-art tests for infection with Mycobacterium tuberculosis - the IFN-γ release assays - rely on accurate measurement of the cytokine IFN-γ. Many other potential biomarkers are expressed in concert with IFN-γ, and IP-10 in particular has shown promising results. IP-10 is produced in large amounts, allowing for the development of new and simplified test platforms, such as lateral flow. In this review, we summarize the results of 22 clinical studies exploring the use of IP-10 as an alternative marker to IFN-γ. The studies report that diagnostic accuracy of IP-10 is on par with IFN-γ, but also that IP-10 may be more robust in young children and in HIV-infected individuals with low CD4 cell counts. We conclude the review by presenting limitations of the published works and outline recent developments and future directions.
Collapse
Affiliation(s)
- Morten Ruhwald
- Clinical Research Centre, Copenhagen University Hospital, Hvidovre, Copenhagen, Denmark.
| | | | | |
Collapse
|
43
|
De Jesús VR, Chace DH. Commentary on the history and quantitative nature of filter paper used in blood collection devices. Bioanalysis 2012; 4:645-7. [PMID: 22452254 PMCID: PMC4634636 DOI: 10.4155/bio.12.34] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|