1
|
Ari A, Raghavan N, Diaz M, Rubin BK, Fink JB. Individualized aerosol medicine: Integrating device into the patient. Paediatr Respir Rev 2024; 49:14-23. [PMID: 37739833 DOI: 10.1016/j.prrv.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 07/12/2023] [Indexed: 09/24/2023]
Abstract
Pulmonary drug delivery is complex due to several challenges including disease-, patient-, and clinicians-related factors. Although many inhaled medications are available in aerosol medicine, delivering aerosolized medications to patients requires effective disease management. There is a large gap in the knowledge of clinicians who select and provide instructions for the correct use of aerosol devices. Since improper device selection, incorrect inhaler technique, and poor patient adherence to prescribed medications may result in inadequate disease control, individualized aerosol medicine is essential for effective disease management and control. The components of individualized aerosol medicine include: (1) Selecting the right device, (2) Selecting the right interface, (3) Educating the patient effectively, and (4) Increasing patient adherence to therapy. This paper reviews each of these components and provides recommendations to integrate the device and interface into the patient for better clinical outcomes.
Collapse
Affiliation(s)
- Arzu Ari
- Texas State University, Department of Respiratory Care, USA.
| | | | - Martha Diaz
- Latin American Board of Certification in Respiratory Therapy, Colombia
| | - Bruce K Rubin
- Virginia Commonwealth University School of Medicine, USA.
| | - James B Fink
- Texas State University, Department of Respiratory Care, USA; Aerogen Pharma, USA.
| |
Collapse
|
2
|
Nolasco S, Manti S, Leonardi S, Vancheri C, Spicuzza L. High-Flow Nasal Cannula Oxygen Therapy: Physiological Mechanisms and Clinical Applications in Children. Front Med (Lausanne) 2022; 9:920549. [PMID: 35721052 PMCID: PMC9203852 DOI: 10.3389/fmed.2022.920549] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 05/09/2022] [Indexed: 11/13/2022] Open
Abstract
High-flow nasal cannula (HFNC) oxygen therapy has rapidly become a popular modality of respiratory support in pediatric care. This is undoubtedly due to its ease of use and safety, which allows it to be used in a wide variety of settings, ranging from pediatric intensive care to patients' homes. HFNC devices make it possible to regulate gas flow and temperature, as well as allowing some nebulized drugs to be administered, features very useful in children, in which the balance between therapeutic effectiveness and adherence to treatment is pivotal. Although the physiological effects of HFNC are still under investigation, their mechanisms of action include delivery of fixed concentration of oxygen, generation of positive end-expiratory pressure, reduction of the work of breathing and clearance of the nasopharyngeal dead space, while providing optimal gas conditioning. Nevertheless, current evidence supports the use of HFNC mainly in moderate-to-severe bronchiolitis, whereas for asthma exacerbations and breath sleeping disorders there is a lack of randomized controlled trials comparing HFNC to continuous positive airway pressure (CPAP) and non-invasive ventilation (NIV), which are essentials for the identification of response and non-response predictors. In this regard, the development of clinical guidelines for HFNC, including flow settings, indications, and contraindications is urgently needed.
Collapse
Affiliation(s)
- Santi Nolasco
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
- *Correspondence: Santi Nolasco
| | - Sara Manti
- Pediatric Pulmonology Unit, Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Salvatore Leonardi
- Pediatric Pulmonology Unit, Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Carlo Vancheri
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Lucia Spicuzza
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| |
Collapse
|
3
|
Li J, Fink JB. Narrative review of practical aspects of aerosol delivery via high-flow nasal cannula. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:590. [PMID: 33987288 DOI: 10.21037/atm-20-7383] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Using high-flow nasal cannula (HFNC) as a "vehicle" to administer aerosolized medication has attracted clinicians' interest in recent years. In this paper, we summarize the current evidence to answer the common questions raised by clinicians about this new aerosol delivery route and best practices of administration. Benefits of trans-nasal aerosol delivery include increased comfort, ability to speak, eat, and drink for patients while meeting a range of oxygen requirements, particularly for those who need to inhale aerosolized medication for long periods. Aerosol administration via HFNC has been shown to be well tolerated by children and adults, with comparable or better delivery efficacy than other interfaces, ranging from 2-20%. In vitro and in vivo scintigraphy studies among pediatric and adult populations reported that the inhaled dose delivered via a vibrating mesh nebulizer is 2 to 3 fold greater than that via a jet nebulizer. For adults, placement of nebulizer at the inlet of humidifier increases inhaled dose while reducing rainout obstructing nasal prongs. When HFNC gas flow is set below patient inspiratory flow, aerosol deposition is higher than when the gas flow exceeds patient inspiratory flow; thus, if tolerated, titrating down HFNC gas flow during trans-nasal aerosol delivery, with close monitoring and the use of unit dose with high concentration are recommended. Trans-nasal pulmonary aerosol delivery has not been shown to increase bioaerosols generated by patients, but gas flow may disperse aerosols. Placement of a surgical or procedure mask over HFNC might reduce aerosol dispersion.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
4
|
Li J, Fink JB, MacLoughlin R, Dhand R. A narrative review on trans-nasal pulmonary aerosol delivery. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2020; 24:506. [PMID: 32807226 PMCID: PMC7430014 DOI: 10.1186/s13054-020-03206-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 07/27/2020] [Indexed: 01/21/2023]
Abstract
The use of trans-nasal pulmonary aerosol delivery via high-flow nasal cannula (HFNC) has expanded in recent years. However, various factors influencing aerosol delivery in this setting have not been precisely defined, and no consensus has emerged regarding the optimal techniques for aerosol delivery with HFNC. Based on a comprehensive literature search, we reviewed studies that assessed trans-nasal pulmonary aerosol delivery with HFNC by in vitro experiments, and in vivo, by radiolabeled, pharmacokinetic and pharmacodynamic studies. In these investigations, the type of nebulizer employed and its placement, carrier gas, the relationship between gas flow and patient’s inspiratory flow, aerosol delivery strategies (intermittent unit dose vs continuous administration by infusion pump), and open vs closed mouth breathing influenced aerosol delivery. The objective of this review was to provide rational recommendations for optimizing aerosol delivery with HFNC in various clinical settings.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| | | | - Rajiv Dhand
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| |
Collapse
|
5
|
Variation in Practice Related to the Use of High Flow Nasal Cannula in Critically Ill Children. Pediatr Crit Care Med 2020; 21:e228-e235. [PMID: 32106187 DOI: 10.1097/pcc.0000000000002258] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To determine current management of critically ill children and gather views regarding high flow nasal cannula therapy and to evaluate research priorities for a large prospective randomized controlled trial of noninvasive respiratory support in children. DESIGN Multinational cross-sectional questionnaire survey conducted in 2018. SETTING The sample included pediatric intensive care physicians in North and South America, Asia, Europe, and Australia/New Zealand. MEASUREMENT Questions consisted of: 1) characteristics of intensivists and hospital, 2) practice of high flow nasal cannula, 3) supportive treatment, and 4) research of high flow nasal cannula. INTERVENTIONS None. MAIN RESULTS We collected data from 1,031 respondents; 919 (North America, 215; Australia/New Zealand, 34; Asia, 203; South America, 186; Europe, 281) were analyzed. Sixty-nine percent of the respondents used high flow nasal cannula in non-PICU settings in their institutions. For a case of bronchiolitis/pneumonia infant, 2 L/kg/min of initial flow rate was the most commonly used. For a scenario of pneumonia with 30 kg weight, more than 60% of the respondents initiated flow based on patient body weight; while, 18% applied a fixed flow rate. Noninvasive ventilation was considered as a next step in more than 85% of respondents when the patient is failing with high flow nasal cannula. Significant practice variations were observed in clinical practice markers used, flow weaning strategy, and supportive practices. Views comparing high flow nasal cannula to continuous positive airway pressure also noticeably varied across the respondents. CONCLUSIONS Significant practice variations including views of high flow nasal cannula compared to continuous positive airway pressure was found among pediatric intensive care physicians. To expedite establishment and standardization of high flow nasal cannula practice, research aimed at understanding the heterogeneity found in this study should be undertaken.
Collapse
|
6
|
Li J, Wei W, Fink JB. In vitro comparison of unit dose vs infusion pump administration of albuterol via high-flow nasal cannula in toddlers. Pediatr Pulmonol 2020; 55:322-329. [PMID: 31782914 DOI: 10.1002/ppul.24589] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 11/10/2019] [Indexed: 01/18/2023]
Abstract
OBJECTIVES Transnasal pulmonary aerosol delivery using high-flow nasal cannula (HFNC) devices has become a popular route of aerosol administration in toddlers. Clinically, albuterol is administered using an infusion pump or unit doses. However, little evidence is available to compare the two administration strategies. METHODS A toddler manikin (15 kg) with appropriate anatomic airway was connected with collecting filter to a simulator of distressed breathing. HFNC device with mesh nebulizer placed at the inlet of a humidifier at 37°C, with the gas flow set at 25 and 3.75 L/min. Five milligrams of albuterol was delivered in all experiments. With infusion pump administration, albuterol concentrations of 5 and 1 mg/mL were delivered at 4 and 20 mL/hr for 15 minutes. With unit dose administration, 1 mL (5 mg/mL) and 2 mL (2.5 mg/mL) of albuterol were nebulized. Additional tests with mouth open and nebulizers via mask were using 5 mg/1 mL for mesh nebulizer and 5 mg/3 mL for jet nebulizer (n = 3). The drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). RESULTS The inhaled dose was higher with unit dose than infusion pump administration with gas flows of 25 L/min (2.66 ± 0.38 vs 1.16 ± 0.28%; P = .004) and 3.75 L/min (10.51 ± 1.29 vs 8.58 ± 0.68%; P = .025). During unit dose administration, compared with closed-mouth breathing, open-mouth breathing generated a higher inhaled dose at 3.75 L/min and lower inhaled dose at 25 L/min. Compared to the nebulizers via mask with both open and closed-mouth breathing, nebulization via HFNC at 3.75 L/min generated greater inhaled dose, while HFNC at 25 L/min generated lower inhaled dose. CONCLUSIONS During transnasal aerosol delivery, the inhaled dose was higher with medication administrated using unit dose than using an infusion pump.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois
| | - Wu Wei
- Department of Critical Care Medicine, Shanghai Zhongshan Hospital, Fu Dan University, Shanghai, China
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois.,Aerogen Pharma Corp, San Mateo, California
| |
Collapse
|
7
|
Li J, Wu W, Fink JB. In vitro comparison between inspiration synchronized and continuous vibrating mesh nebulizer during trans-nasal aerosol delivery. Intensive Care Med Exp 2020; 8:6. [PMID: 32006290 PMCID: PMC6994578 DOI: 10.1186/s40635-020-0293-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 01/14/2020] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Compared to continuous vibrating mesh nebulizer (VMN), inspiration synchronized VMN has shown increased inhaled dose during noninvasive ventilation; however, its use during aerosol delivery via high-flow nasal cannula (HFNC) is still unknown. METHODS An adult manikin was connected to a dual-chamber model lung, which was driven by a critical care ventilator to simulate spontaneous breathing. A HFNC system was utilized with temperature at 37 ° C while gas flow at 5, 10, 20, 40, and 60 L/min. Inspiration synchronized and continuous aerosol generation were compared at different positions (at the inlet of humidifier vs close to patient). One milliliter of albuterol (2.5 mg/mL) was used in each run (n = 3). Collection filter was placed at the trachea and was removed after each run. Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). RESULTS When nebulizer was placed close to patient, inhaled dose was higher with inspiration synchronized than continuous aerosol generation at all gas flows (p = 0.05) except at 5 L/min. When placed at the inlet of humidifier, compared to continuous, inspiration synchronized aerosol generated higher inhaled dose with gas flow set below 50% of patient inspiratory flow [23.9 (20.6, 28.3)% vs 18.1 (16.7, 19.6)%, p < 0.001], but lower inhaled dose with gas flow set above 50% of patient inspiratory flow [3.5 (2.2, 9.3)% vs 9.9 (8.2, 16.4)%, p = 0.001]. Regardless of breathing pattern, continuous aerosol delivered greater inhaled dose with nebulizer placed at humidifier than close to patient at all gas flows except at 5 L/min. CONCLUSION When the HFNC gas flow was set higher than 50% of patient inspiratory flow, no significant advantage was found in inspiration synchronized over continuous aerosol. However, inspiration synchronized aerosol generated 30% more inhaled dose than continuous with gas flow set below 50% of patient inspiratory flow, regardless of nebulizer placement. Continuous nebulizer needs to be placed at the inlet of humidifier.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - Wei Wu
- Department of Critical Care Medicine, Shanghai Zhongshan Hospital, Fu Dan University, Shanghai, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA
- Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
8
|
Dugernier J, Reychler G, Vecellio L, Ehrmann S. Nasal High-Flow Nebulization for Lung Drug Delivery: Theoretical, Experimental, and Clinical Application. J Aerosol Med Pulm Drug Deliv 2019; 32:341-351. [DOI: 10.1089/jamp.2019.1524] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Jonathan Dugernier
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Soins Intensifs, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Médecine Physique, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Grégory Reychler
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Service de pneumologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Laurent Vecellio
- Centre d'études des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Stephan Ehrmann
- Centre d'études des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
- Médecine intensive réanimation, Centre d'investigation clinique CIC INSERM 1415, CHRU de Tours, Tours, France
- CRICS-TriggerSep Research Network
| |
Collapse
|
9
|
Abstract
The 2014 American Academy of Pediatrics bronchiolitis guidelines do not adequately serve the needs and clinical realities of front-line clinicians caring for undifferentiated wheezing infants and children. This article describes the clinical challenges of evaluating and managing a heterogeneous disease syndrome presenting as undifferentiated patients to the emergency department. Although the 2014 American Academy of Pediatrics bronchiolitis guidelines and the multiple international guidelines that they closely mirror have made a good faith attempt to provide clinicians with the best evidence-based recommendations possible, they have all failed to address practical, front-line clinical challenges. The therapeutic nihilism of the guidelines and the dissonance between many of the recommendations and frontline realities have had wide-ranging consequences. Nevertheless, newer evidence of therapeutic options is emerging and forecasts hope for more therapeutically optimistic recommendations with the next revision of the guidelines.
Collapse
|
10
|
Li J, Zhao M, Hadeer M, Luo J, Fink JB. Dose Response to Transnasal Pulmonary Administration of Bronchodilator Aerosols via Nasal High-Flow Therapy in Adults with Stable Chronic Obstructive Pulmonary Disease and Asthma. Respiration 2019; 98:401-409. [PMID: 31473748 DOI: 10.1159/000501564] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 06/17/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND There has been increasing interest in transnasal pulmonary aerosol administration, but the dose-response relationship has not been reported. OBJECTIVES To determine the accumulative bronchodilator dose at which patients with stable mild-to-moderate asthma and chronic obstructive pulmonary disease (COPD) achieve similar spirometry responses before and after bronchodilator tests using albuterol via a metered dose inhaler with a valved holding chamber (MDI + VHC). METHOD Adult patients who met ATS/ERS criteria for bronchodilator responses in pulmonary function laboratory were recruited and consented to participate. After a washout period, patients received escalating doubling dosages (0.5, 1, 2, and 4 mg) of albuterol in a total volume of 2 mL delivered by vibrating mesh nebulizer via a nasal cannula at 37°C with a flow rate of 15-20 L/min using a Venturi air entrainment device. Spirometry was measured at baseline and after each dose. Titration was stopped when an additional forced expiratory volume in 1 second (FEV1) improvement was <5%. RESULTS 42 patients (16 males) with stable mild-to-moderate asthma (n = 29) and COPD (n = 13) were enrolled. FEV1 increment after a cumulative dose of 1.5 mg of albuterol via nasal cannula at 15-20 L/min was similar to 4 actuations of MDI + VHC (0.34 ± 0.18 vs. 0.34 ± 0.12 L, p = 0.878). Using ATS/ERS criteria of the bronchodilator test, 33.3% (14/42) and 69% (29/42) of patients responded to 0.5 and 1.5 mg of albuterol, respectively. CONCLUSIONS With a nasal cannula at 15-20 L/min, transnasal pulmonary delivery of 1.5 mg albuterol resulted in similar bronchodilator response as 4 actuations of MDI + VHC.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois, USA,
| | - Minghua Zhao
- Division of Pulmonary Function Test Laboratory, Department of Respiratory Care, People's Hospital of the Xinjiang Autonomous Region, Urumqi, China
| | - Maierbati Hadeer
- Division of Pulmonary Function Test Laboratory, Department of Respiratory Care, People's Hospital of the Xinjiang Autonomous Region, Urumqi, China
| | - Jian Luo
- Department of Respiratory and Critical Care Medicine, West China School of Medicine and West China Hospital, Sichuan University, Chengdu, China
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois, USA.,Aerogen Pharma Corporation, San Mateo, California, USA
| |
Collapse
|
11
|
Li J, Luo J, Chen Y, Xie L, Fink JB. Effects of flow rate on transnasal pulmonary aerosol delivery of bronchodilators via high-flow nasal cannula for patients with COPD and asthma: protocol for a randomised controlled trial. BMJ Open 2019; 9:e028584. [PMID: 31239304 PMCID: PMC6597746 DOI: 10.1136/bmjopen-2018-028584] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
INTRODUCTION Both in vitro and in vivo radiolabelled studies on nebulisation via high-flow nasal cannula showed that inhaled dose decreases as the administered gas flow increases. In our previous in vitro study, we investigated the effects of the ratio of gas flow to subject's peak inspiratory flow (GF:IF) on the aerosol deposition, which increased as the GF:IF decreased, with an optimal GF:IF between 0.1 and 0.5 producing a stable 'lung' deposition in both quiet and distressed breathing. Thus, we aim to validate our in vitro findings in subjects with reversible airflow limitations by assessing their response to inhaled bronchodilator. METHODS AND ANALYSIS This is a single-centre, randomised controlled trial. Subjects with chronic obstructive pulmonary disease or asthma with positive response to 400μg albuterol via metered dose inhaler and valved holding chamber will be enrolled and consented. After a washout period (1-3 days), subjects will be randomly assigned to inhale albuterol with one of three gas flows: 50 L/min, GF:IF=1.0 and GF:IF=0.5. In each arm, subjects will inhale 2 mL saline, followed by escalating doubling doses (0.5, 1, 2 and 4 mg) of albuterol in a fill volume of 2 mL, delivered by a vibrating mesh nebuliser via heated nasal cannula set up at 37°C. An interval of 30 min between each dose of albuterol, with spirometry measured at baseline and after each inhalation. Titration will be terminated if forced expiratory volume in 1 s improvement is <5%, or adverse event is observed. ETHICS AND DISSEMINATION This trial has been approved by the Ethic Committee of People's Liberation Army General Hospital, Beijing, China (no. S2018-200-01). The results will be disseminated through peer-reviewed journals, national and international conferences. TRIAL REGISTRATION NUMBER NCT03739359; Pre-results.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois, USA
| | - Jian Luo
- Department of Pulmonary and Critical Care Medicine, Sichuan University West China Hospital, Chengdu, China
| | - Yibing Chen
- Department of Respiratory and Critical Care Medicine, Pulmonary Function Test Lab, General Hospital of People’s Liberation Army, Beijing, China
| | - Lixing Xie
- Department of Respiratory and Critical Care Medicine, Pulmonary Function Test Lab, General Hospital of People’s Liberation Army, Beijing, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois, USA
- Aerogen Pharma Corp, San Mateo, California, USA
| |
Collapse
|
12
|
Li J, Harnois LJ, Markos B, Roberts KM, Homoud SA, Liu J, Mirza S, Vines D. Epoprostenol Delivered via High Flow Nasal Cannula for ICU Subjects with Severe Hypoxemia Comorbid with Pulmonary Hypertension or Right Heart Dysfunction. Pharmaceutics 2019; 11:pharmaceutics11060281. [PMID: 31207936 PMCID: PMC6631264 DOI: 10.3390/pharmaceutics11060281] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/06/2019] [Accepted: 06/10/2019] [Indexed: 12/20/2022] Open
Abstract
Inhaled epoprostenol (iEPO) has been utilized to improve oxygenation in mechanically ventilated subjects with severe hypoxemia, but the evidence for iEPO via high-flow nasal cannula (HFNC) is rare. Following approval by the institutional review board, this retrospective cohort study evaluated subjects who received iEPO via HFNC for more than 30 min to treat severe hypoxemia comorbid with pulmonary hypertension or right heart dysfunction between July 2015 and April 2018. A total of 11 subjects were enrolled in the study of whom 4 were male (36.4%), age 57.5 ± 22.1 years, and APACHE II score at ICU admission was 18.5 ± 5.7. Ten subjects had more than three chronic heart or lung comorbidities; seven of them used home oxygen. After inhaling epoprostenol, subjects' SpO2/FIO2 ratio improved from 107.5 ± 26.3 to 125.5 ± 31.6 (p = 0.026) within 30-60 min. Five subjects (45.5%) had SpO2/FIO2 improvement >20%, which was considered as a positive response. Heart rate, blood pressure, and respiratory rate were not significantly different. Seven subjects did not require intubation, and seven subjects were discharged home. This retrospective study demonstrated the feasibility of iEPO via HFNC in improving oxygenation. Careful titration of flow while evaluating subjects' response may help identify responders and avoid delaying other interventions. This study supports the need for a larger prospective randomized control trial to further evaluate the efficacy of iEPO via HFNC in improving outcomes.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Lauren J Harnois
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Bethelhem Markos
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Keith M Roberts
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Salma Al Homoud
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Jing Liu
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Sara Mirza
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - David Vines
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| |
Collapse
|
13
|
Li J, Gong L, Ari A, Fink JB. Decrease the flow setting to improve trans-nasal pulmonary aerosol delivery via "high-flow nasal cannula" to infants and toddlers. Pediatr Pulmonol 2019; 54:914-921. [PMID: 30920155 DOI: 10.1002/ppul.24274] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Accepted: 01/16/2019] [Indexed: 11/07/2022]
Abstract
OBJECTIVES Trans-nasal pulmonary aerosol delivery for infants and toddlers has recently gained popularity, however, the reported lung deposition is low. We aimed to investigate the influential factors to improve the delivery. METHODS Anatomic airway manikins simulating infant (5 kg) and toddler (15 kg) with collecting filter connected the trachea and breath simulator, were set to represent quiet and distressed breathing. Nasal cannula flow was set at 0.125, 0.25, 0.5, 1, and 2 L/kg/min. A mesh nebulizer (Aerogen) was placed at the inlet of humidifier (Fisher & Paykel) and proximal to patient. Albuterol (5 mg in 1 mL) was nebulized for each condition (n = 3). Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). RESULTS Inhaled dose was higher with nebulizer placed at the inlet of humidifier than proximal to patient in all settings, except the infant model at low gas flow settings (0.125 and 0.25 L/kg/min). When nebulizer was placed at the inlet of humidifier, inhaled dose was higher when gas flow was below patient's inspiratory flow than when gas flow exceeded patient's inspiratory flow (8.77 ± 3.84 vs 2.16 ± 1.29%, P < 0.001); aerosol deposition increased as gas flow decreased, with greatest deposition at gas flow of 0.25 L/kg/min (11.29 ± 2.15%). A multiple linear regression identified gas flow as the primary predictor of aerosol delivery. CONCLUSIONS Trans-nasal pulmonary aerosol delivery was significantly improved when gas flow was below patient's inspiratory flow, aerosol deposition increased with decreased nasal cannula flow, with greatest deposition at 0.25 L/kg/min.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, Illinois
| | - Lingyue Gong
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, Illinois
| | - Arzu Ari
- Department of Respiratory Care, College of Health Professions, Texas State University, Round Rock, Texas
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, Illinois
- Aerogen Pharma Corp, San Mateo, California
| |
Collapse
|
14
|
The Ratio of Nasal Cannula Gas Flow to Patient Inspiratory Flow on Trans-nasal Pulmonary Aerosol Delivery for Adults: An in Vitro Study. Pharmaceutics 2019; 11:pharmaceutics11050225. [PMID: 31083346 PMCID: PMC6571744 DOI: 10.3390/pharmaceutics11050225] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 11/17/2022] Open
Abstract
Trans-nasal aerosol deposition during distressed breathing is higher than quiet breathing, and decreases as administered gas flow increases. We hypothesize that inhaled dose is related to the ratio of gas flow to patient inspiratory flow (GF:IF). An adult manikin (Laerdal) with a collecting filter placed at trachea was connected to a dual-chamber model lung, which was driven by a ventilator to simulate quiet and distressed breathing with different inspiratory flows. Gas flow was set at 5, 10, 20, 40 and 60 L/min. Albuterol (2.5mg in 1 mL) was nebulized by vibrating mesh nebulizer at the inlet of humidifier at 37 °C for each condition (n = 3). Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). GF:IF was the primary predictor of inhaled dose (p < 0.001). When the ratio was < 1.0, the inhaled dose was higher than ratio > 1.0 (21.8 ± 3.8% vs. 9.0 ± 3.7%, p < 0.001), and the inhaled dose was similar between quiet and distressed breathing (22.3 ± 5.0% vs. 21.3 ± 2.7%, p = 0.379). During trans-nasal aerosol delivery, GF:IF primarily affected the inhaled dose. Compared to the ratio above 1.0, the ratio below 1.0 produced a higher and more-consistent inhaled dose.
Collapse
|
15
|
Bennett G, Joyce M, Fernández EF, MacLoughlin R. Comparison of aerosol delivery across combinations of drug delivery interfaces with and without concurrent high-flow nasal therapy. Intensive Care Med Exp 2019; 7:20. [PMID: 30945044 PMCID: PMC6447636 DOI: 10.1186/s40635-019-0245-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 03/25/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Current clinical practice during high-flow nasal therapy (HFNT) involves utilization of a nasal cannula to provide humidification, with a facemask placed over the cannula to deliver aerosol. Few studies have compared aerosol delivery across various delivery interfaces during HFNT. The objective of this study was to address this gap in the literature and evaluate aerosol delivery using two nebulizer types across different drug delivery interfaces, nasal cannula, facemask, and mouthpiece, during simulated adult HFNT. METHODS A facemask or mouthpiece and/or a nasal cannula were positioned on an anatomically correct adult head model. The head model was connected to a breathing simulator via a collection filter. Both healthy breathing pattern and distressed breathing patterns were utilized. Aerosol dose was determined by quantifying the mass of drug captured on a filter positioned distal to the trachea. RESULTS During simulated healthy breathing, a significantly greater aerosol dose was observed when the vibrating mesh nebulizer (VMN) was integrated with HFNT alone, supplying aerosol and humidified air simultaneously (2.88 ± 0.15%), as opposed to using with a facemask (0.33 ± 0.07%, 1.62 ± 0.46%, and 1.07 ± 0.25% at 0 L/min (LPM), 2LPM, and 6LPM, respectively) or mouthpiece (0.56 ± 0.13%, 2.16 ± 0.06%, and 1.82 ± 0.41% at 0LPM, 2LPM, and 6LPM). In addition, aerosol delivery was also significantly greater when the VMN was integrated into simulated HFNT (2.88 ± 0.15%), in comparison with using the jet nebulizer (JN) with a facemask (0.82 ± 0.16%) or a mouthpiece (0.86 ± 0.11%). During simulated distressed breathing, a significantly greater aerosol dose was observed when the VMN was integrated with HFNT, supplying aerosol and humidified air simultaneously (6.81 ± 0.45%), compared with using a facemask (0.86 ± 0.04%, 2.96 ± 0.26%, and 4.23 ± 0.93% at 0LPM, 2LPM, and 6LPM) or mouthpiece (0.73 ± 0.37%, 0.97 ± 0.20%, and 3.11 ± 0.53% at 0LPM, 2LPM, and 6LPM, respectively). Aerosol delivery was also greater when the VMN was integrated into HFNT (6.81 ± 0.45%), in comparison with using the JN with a facemask (5.72 ± 0.71%) or a mouthpiece (0.69 ± 0.53%). Furthermore, across all drug delivery interfaces, and in line with previous reports, aerosol delivery was greater during simulated distressed breathing, in comparison with simulated healthy adult breathing. CONCLUSIONS This article will be of considerable benefit in enhancing the understanding of aerosol delivery during HFNT, an increasingly adopted therapeutic intervention by healthcare professionals.
Collapse
Affiliation(s)
- Gavin Bennett
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | - Mary Joyce
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | | | | |
Collapse
|
16
|
In Vitro Study of the Effect of Breathing Pattern on Aerosol Delivery During High-Flow Nasal Therapy. Pulm Ther 2019; 5:43-54. [PMID: 32026423 PMCID: PMC6967176 DOI: 10.1007/s41030-019-0086-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Indexed: 12/02/2022] Open
Abstract
Introduction The use of concurrent aerosol delivery during high-flow nasal therapy (HFNT) may be exploited to facilitate delivery of a variety of prescribed medications for inhalation. The study assessed the effect of tidal volume, breath rate, and inspiratory:expiratory (I:E) ratio on the quantity of aerosol captured at the level of the trachea during simulated HFNT. Methods Testing was completed according to a factorial statistical design of experiments (DOE) approach. Tracheal dose was characterized with a vibrating mesh nebulizer (Aerogen Solo, Aerogen Ltd) using simulated adult, small child, and infant HFNT models. Furthermore, aerosol delivery was evaluated across a range of adult patient profiles with clinically representative test setups. Results Aerosol delivery increased with a large tidal volume, a rapid breath rate, and a long inspiratory time. Tidal volume, breath rate, and I:E ratio each had a significant effect on tracheal dose across simulated adult, small child, and infant breathing. Conclusion The main trends that were identified in the statistical DOE predicted aerosol delivery across adult patient breathing profiles, in terms of tidal volume, breath rate, and I:E ratio. Therefore, patients with distressed breathing profiles may be expected to receive a larger aerosol dose than those with normal breathing rates. Funding Aerogen Limited.
Collapse
|
17
|
Reminiac F, Vecellio L, Bodet-Contentin L, Gissot V, Le Pennec D, Salmon Gandonnière C, Cabrera M, Dequin PF, Plantier L, Ehrmann S. Nasal high-flow bronchodilator nebulization: a randomized cross-over study. Ann Intensive Care 2018; 8:128. [PMID: 30570679 PMCID: PMC6301902 DOI: 10.1186/s13613-018-0473-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 12/11/2018] [Indexed: 01/14/2023] Open
Abstract
Background There is an absence of controlled clinical data showing bronchodilation effectiveness after nebulization via nasal high-flow therapy circuits. Results Twenty-five patients with reversible airflow obstruction received, in a randomized order: (1) 2.5 mg albuterol delivered via a jet nebulizer with a facial mask; (2) 2.5 mg albuterol delivered via a vibrating mesh nebulizer placed downstream of a nasal high-flow humidification chamber (30 L/min and 37 °C); and (3) nasal high-flow therapy without nebulization. All three conditions induced significant individual increases in forced expiratory volume in one second (FEV1) compared to baseline. The median change was similar after facial mask nebulization [+ 350 mL (+ 180; + 550); + 18% (+ 8; + 30)] and nasal high flow with nebulization [+ 330 mL (+ 140; + 390); + 16% (+ 5; + 24)], p = 0.11. However, it was significantly lower after nasal high-flow therapy without nebulization [+ 50 mL (− 10; + 220); + 3% (− 1; + 8)], p = 0.0009. FEV1 increases after facial mask and nasal high-flow nebulization as well as residual volume decreases were well correlated (p < 0.0001 and p = 0.01). Both techniques showed good agreement in terms of airflow obstruction reversibility (kappa 0.60). Conclusion Albuterol vibrating mesh nebulization within a nasal high-flow circuit induces similar bronchodilation to standard facial mask jet nebulization. Beyond pharmacological bronchodilation, nasal high flow by itself may induce small but significant bronchodilation. Electronic supplementary material The online version of this article (10.1186/s13613-018-0473-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- François Reminiac
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Clinique du Mail, La Rochelle, France
| | - Laurent Vecellio
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Laetitia Bodet-Contentin
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Valérie Gissot
- Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France
| | - Deborah Le Pennec
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Charlotte Salmon Gandonnière
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Maria Cabrera
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Pierre-François Dequin
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Laurent Plantier
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Service de pneumologie et d'explorations fonctionnelles respiratoires, CHRU de Tours, Tours, France
| | - Stephan Ehrmann
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France. .,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France. .,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France. .,CRICS-TRIGGERSEP Network, Tours, France.
| |
Collapse
|
18
|
Bennett G, Joyce M, Sweeney L, MacLoughlin R. In Vitro Determination of the Main Effects in the Design of High-Flow Nasal Therapy Systems with Respect to Aerosol Performance. Pulm Ther 2018; 4:73-86. [PMID: 32026245 PMCID: PMC6967237 DOI: 10.1007/s41030-018-0054-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Indexed: 12/31/2022] Open
Abstract
INTRODUCTION The use of concurrent aerosol delivery during high-flow nasal therapy (HFNT) may be exploited to facilitate the delivery of a variety of prescribed medications for inhalation. Until now, a systematic approach to determine the conditions required to yield an optimal emitted dose has not been reported. The aim of this study was to establish the effects of gas flow rate, input droplet size, and nebulizer position on the amount of aerosol exiting the nasal cannula during HFNT and thus becoming available for inhalation. METHODS Testing was completed according to a factorial statistical design of experiments (DOE) approach. Emitted dose was characterized with a vibrating mesh nebulizer (Aerogen Solo, Aerogen Ltd) for an adult model of HFNT at three clinically relevant gas flow rates, using three nebulizers producing varying input droplet sizes and placed at two different nebulizer positions. RESULTS Increasing the gas flow rate significantly lowered the emitted dose, with a dose of 7.10% obtained at 10 LPM, 2.67% at 25 LPM, and 1.30% at 40 LPM (p < 0.0001). There was a significant difference in emitted dose between nebulizers with different input droplet sizes, with increasing input droplet size associated with a reduced emitted dose (6.11% with an input droplet size of 3.22 µm, 2.76% with 4.05 µm, and 2.38% with 4.88 µm, p = 0.0002, Pearson's r = - 0.2871). In addition, the droplet size exiting the nasal cannula interface was lower than that produced by the aerosol generator for all devices under test. Positioning the nebulizer immediately after the humidification chamber yielded a marginally greater emitted dose (3.79%) than when the nebulizer was placed immediately upstream of the nasal cannula (3.39%). Flow rate, input droplet size, and nebulizer position were at the 0.10 level of significance, indicating that all three factors had significant effects on emitted dose. According to the DOE model, flow rate had the greatest influence on emitted dose, followed by input droplet size and then nebulizer position. CONCLUSION Our findings indicate that in order to optimize the amount of aerosol exiting the nasal cannula interface during HFNT, it is necessary for gas flow rate to be low and the input droplet size to be small, while the nebulizer should be positioned immediately after the humidification chamber. FUNDING Aerogen Limited.
Collapse
Affiliation(s)
- Gavin Bennett
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland.
| | - Mary Joyce
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | - Louise Sweeney
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | | |
Collapse
|
19
|
|
20
|
Ehrmann S. Vibrating Mesh Nebulisers – Can Greater Drug Delivery to the Airways and Lungs Improve Respiratory Outcomes? ACTA ACUST UNITED AC 2018. [DOI: 10.17925/erpd.2018.4.1.33] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Aerosols are an increasingly important mode of delivery of drugs, particularly bronchodilators, for the treatment of respiratory diseases, notably asthma and chronic obstructive pulmonary disease. The most common type of nebuliser is the jet nebuliser (JN); they have been in use for more than a century but these devices can be cumbersome to use and may sometimes deliver insufficient amounts of drug. A more recent development in aerosol therapy is the vibrating mesh nebuliser (VMN) which is very user friendly and is more efficient than the JNs due to an extremely low residual volume. Scintigraphy images from studies of volunteer subjects using radio-labelled aerosol treatment show that VMN-generated aerosols deliver more drug to patients in a shorter period of time than JN-generated aerosols. Various bench, animal model and small clinical studies have shown that VMNs are more efficient than JNs in drug delivery, potentially improving clinical outcomes. These studies have included various breathing circuits used in mechanical ventilation (MV), non-invasive ventilation, high-flow nasal cannula systems and devices for spontaneously breathing patients. The efficiency of drug delivery was affected by factors including the position of the nebuliser in the circuit and humidity. Some studies have shown potential substantial savings by hospitals in the cost of MV treatments after switching from metered dose inhalers to VMNs. VMNs have also been shown to be effective for the administration of inhaled antibiotics, corticosteroids and other drugs. Larger studies of the effects of VMNs on patient outcomes are needed but they are likely to be an increasingly important means of administering therapies to a burgeoning population with respiratory disease.
Collapse
|
21
|
Al-Subu AM, Hagen S, Eldridge M, Boriosi J. Aerosol therapy through high flow nasal cannula in pediatric patients. Expert Rev Respir Med 2017; 11:945-953. [PMID: 28994337 DOI: 10.1080/17476348.2017.1391095] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
INTRODUCTION High flow nasal cannula (HFNC) is increasingly used in pediatric patients suffering from respiratory failure. In some disease processes, patients may also benefit from aerosol therapy. Therefore, the use of HFNC to deliver aerosolized medications is a convenient and attractive option. Areas covered: This review aims to appraise available evidence concerning the efficiency of aerosol nebulized therapy delivery using HFNC in pediatric patients. Expert commentary: Delivery of aerosol particles is a very complex process and depends on the use of oxygen vs. heliox, nebulizer type and position within the HFNC circuit, patient's breathing effort and pattern, and more importantly cannula size and flow rates. Current in vitro evidence suggests the amount of aerosol delivery is likely to be very low at high flows. Clinical studies are limited in pediatric patients and given the limited clinical data, it is not possible to make recommendations for or against aerosol delivery through HFNC for pediatric patients.
Collapse
Affiliation(s)
- Awni M Al-Subu
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Scott Hagen
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Marlowe Eldridge
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Juan Boriosi
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| |
Collapse
|
22
|
Dugernier J, Hesse M, Jumetz T, Bialais E, Roeseler J, Depoortere V, Michotte JB, Wittebole X, Ehrmann S, Laterre PF, Jamar F, Reychler G. Aerosol Delivery with Two Nebulizers Through High-Flow Nasal Cannula: A Randomized Cross-Over Single-Photon Emission Computed Tomography-Computed Tomography Study. J Aerosol Med Pulm Drug Deliv 2017; 30:349-358. [PMID: 28463044 DOI: 10.1089/jamp.2017.1366] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). METHODS Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo®; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer®; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow®; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. RESULTS Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. CONCLUSIONS In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.
Collapse
Affiliation(s)
- Jonathan Dugernier
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Michel Hesse
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | | | - Emilie Bialais
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Jean Roeseler
- 2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Virginie Depoortere
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Jean-Bernard Michotte
- 5 Haute Ecole de Santé Vaud, Filière Physiothérapie, University of Applied Sciences and Arts Western Switzerland , Lausanne, Switzerland
| | - Xavier Wittebole
- 2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Stephan Ehrmann
- 6 Université François Rabelais , Tours, France .,7 INSERM, Centre d'étude des Pathologies Respiratoires , Tours, France .,8 CHRU de Tours, Réanimation Polyvalente , Tours, France
| | | | - François Jamar
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Gregory Reychler
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,9 Pneumologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| |
Collapse
|
23
|
Réminiac F, Vecellio L, Loughlin RM, Le Pennec D, Cabrera M, Vourc'h NH, Fink JB, Ehrmann S. Nasal high flow nebulization in infants and toddlers: An in vitro and in vivo scintigraphic study. Pediatr Pulmonol 2017; 52:337-344. [PMID: 27392199 DOI: 10.1002/ppul.23509] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/20/2016] [Accepted: 06/08/2016] [Indexed: 12/15/2022]
Abstract
Aerosol therapy in infants and toddlers is challenging. Nebulization within a nasal high flow (NHF) circuit is attractive. The aim of this study was to quantify aerosol lung deposition when combined with NHF as compared with standard practice. Lung doses were measured scintigraphically after nebulization with jet and mesh nebulizer placed within a NHF circuit in a spontaneously breathing non-human primate model (macaque) and in the anatomical bench SAINT model, respectively representing a full-term newborn and a 9-month-old toddler. In the SAINT model, lung depositions observed with the mesh nebulizer placed in the NHF circuit set at 2 and 4 L/min were 3.3% and 4.2% of the nebulizer charge, respectively, and similar to the 1.70% observed with the control standard facemask jet nebulization (6 L/min flow). In the macaque model, the depositions observed with the mesh nebulizer in the NHF circuit set at 2 and 4 L/min were 0.49% and 0.85%, respectively, also similar to the control measurement (0.71%). Mesh nebulization within a NHF circuit set at 8 L/min and jet nebulization either within a NHF circuit or placed on top of the cannula (NHF set at 2 L/min; total flow of 8 L/min), resulted in a significantly lower lung depositions. Mesh nebulization within a NHF circuit delivering up to 4 L/min gas is likely to be at least as effective than jet nebulization with a facemask in infants and toddlers. Aerosol facemask placement on top of cannulas or jet nebulization within the NHF circuit may be less effective. Pediatr Pulmonol. 2017;52:337-344. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- François Réminiac
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France.,CHRU de Tours, Anesthésie-réanimation, Tours, France.,CHRU de Tours, Réanimation polyvalente, Tours, France
| | - Laurent Vecellio
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France.,Faculté de médecine, Aerodrug, DTF Medical, Tours, France
| | | | - Deborah Le Pennec
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France
| | - Maria Cabrera
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France
| | - Nathalie Heuzé Vourc'h
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France
| | | | - Stephan Ehrmann
- Université François Rabelais, Tours, France.,INSERM, Centre d'Étude des Pathologies Respiratoires, Tours, France.,CHRU de Tours, Réanimation polyvalente, Tours, France
| |
Collapse
|
24
|
Vandini S, Faldella G, Lanari M. Latest options for treatment of bronchiolitis in infants. Expert Rev Respir Med 2016; 10:453-461. [PMID: 26901672 DOI: 10.1586/17476348.2016.1157473] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Bronchiolitis is the most frequent pathology associated with lower respiratory tract infection in newborns and young infants. The treatment of bronchiolitis is essentially supportive therapy for respiratory distress, hypoxia and dehydration. To date, no specific antiviral drug is used on a routine basis for the treatment of RSV infections. Currently, the only antiviral drug approved for the infection is ribavirin; however, its use is limited due to adverse side effects and the risks it poses to healthcare providers. Moreover, several drugs have been routinely administered for years in infants with acute RSV bronchiolitis, even if their efficacy is often not confirmed by clinical evidence, and studies on emerging antiviral drugs are still ongoing. In the present paper we review the recent literature about the drugs used during acute bronchiolitis and we summarize the main recommendations of national and international guidelines and the latest options for the treatment of bronchiolitis.
Collapse
Affiliation(s)
- Silvia Vandini
- a Neonatology and Neonatal Intensive Care Unit, S.Orsola-Malpighi Hospital, University of Bologna , Bologna , Italy
| | - Giacomo Faldella
- a Neonatology and Neonatal Intensive Care Unit, S.Orsola-Malpighi Hospital, University of Bologna , Bologna , Italy
| | - Marcello Lanari
- b Pediatrics and Neonatology Unit , Imola Hospital , Imola , Italy
| |
Collapse
|
25
|
Kikidis D, Konstantinos V, Tzovaras D, Usmani OS. The Digital Asthma Patient: The History and Future of Inhaler Based Health Monitoring Devices. J Aerosol Med Pulm Drug Deliv 2016; 29:219-32. [PMID: 26919553 DOI: 10.1089/jamp.2015.1267] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The wave of digital health is continuously growing and promises to transform healthcare and optimize the patients' experience. Asthma is in the center of these digital developments, as it is a chronic disease that requires the continuous attention of both health care professionals and patients themselves. The accurate and timely assessment of the state of asthma is the fundamental basis of digital health approaches and is also the most significant factor toward the preventive and efficient management of the disease. Furthermore, the necessity of inhaled medication offers a basic platform upon which modern technologies can be integrated, namely the inhaler device itself. Inhaler-based monitoring devices were introduced in the beginning of the 1980s and have been evolving but mainly for the assessment of medication adherence. As technology progresses and novel sensing components are becoming available, the enhancement of inhalers with a wider range of monitoring capabilities holds the promise to further support and optimize asthma self-management. The current article aims to take a step for the mapping of this territory and start the discussion among healthcare professionals and engineers for the identification and the development of technologies that can offer personalized asthma self-management with clinical significance. In this direction, a technical review of inhaler based monitoring devices is presented, together with an overview of their use in clinical research. The aggregated results are then summarized and discussed for the identification of key drivers that can lead the future of inhalers.
Collapse
Affiliation(s)
- Dimitrios Kikidis
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Votis Konstantinos
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Dimitrios Tzovaras
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Omar S Usmani
- 2 Imperial College London and Royal Brompton Hospital, National Heart and Lung Institute , London, United Kingdom
| |
Collapse
|
26
|
Réminiac F, Bodet-Contentin L, Vecellio L, Dequin PF, Ehrmann S. Aérosolthérapie au cours de l’assistance respiratoire non invasive. MEDECINE INTENSIVE REANIMATION 2016. [DOI: 10.1007/s13546-015-1158-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|