Borrillo F, Panteghini M. Current performance of C-reactive protein determination and derivation of quality specifications for its measurement uncertainty. Clin Chem Lab Med 2023; 61:1552-1557. [PMID: 36773318 DOI: 10.1515/cclm-2023-0069] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 01/31/2023] [Indexed: 02/13/2023]
Abstract
From External Quality Assessment data, current harmonization of CRP measuring systems appears to be satisfactory, the inter-assay CV being well below 10%. The inter-method variability is even better (close to 3%) when the widely used measuring systems are compared at CRP concentrations employed as cut-off for detecting sub-clinical infection (i.e., 10.0 mg/L) and measurement variability estimated, according to ISO 20914:2019 Technical Specification, from the intermediate within-lab reproducibility of 6-month consecutive measurement data. According to the state-of-the-art model (which is better suited for CRP), the maximum allowable measurement uncertainty (MAU) for CRP measurement on clinical samples with 10.0 mg/L concentrations is 3.76% (desirable quality). As measurement uncertainty (MU) of the only available reference material (ERM-DA474/IFCC) is ∼3%, to fulfil desirable MAU on clinical samples, IVD manufacturers should work to keep the contribution of remaining MU sources (commercial calibrator and intermediate within-lab reproducibility) lower than 2.3%.
Collapse
Affiliation(s)
- Francesca Borrillo
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
- Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
2
|
Performance evaluation of 14 specific proteins measurement checked by an External Quality Assessment Scheme. Clin Chim Acta 2019; 502:73-83. [PMID: 31836500 DOI: 10.1016/j.cca.2019.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 11/18/2019] [Accepted: 11/18/2019] [Indexed: 11/23/2022]
Abstract
AIMS OF THE STUDY To evaluate the state-of-the-art of 14 specific proteins measurement; to evaluate the laboratories' performance and the degree of harmonization in reporting results of participants in the External Quality Assessment Program of the Centre of Biomedical Research (CRB). METHODS Overall and system-related inter-laboratory analytical variability (mean CVs%) and between-system differences (mean bias%) were evaluated from data of six EQA cycles 2013-2018. Moreover, we evaluated the analytical performance of participants as well as the units used to express proteins results. RESULTS Overall inter-laboratory variability ranged from 3.8% for haptoglobin (HPT) to 12.5% for α1-antitrypsin (AAT) and decreased for IgA, α2-macroglobulin (A2M) and transferrin (TRF). Mean CVs% were generally higher for Siemens BN and Beckman Immage immunonephelometric systems, but <7.0% for all proteins. Mean bias > 7.0% was observed for BN (IgA, C4, AAT, transthyretin TTR), Siemens Vista (IgA, C4) and Immage (C4), whereas mean bias < -7.0% was found for Immage (AAT), Beckman AU (IgM) and Roche Cobas (C4, TTR, C-reactive protein). The laboratories' performance within the limits ranged from 85.1% of albumin (ALB) to 97.2% of HPT. The census of units employed in 2018, demonstrated that ~ 70% of laboratories still express the results in mg/dL. CONCLUSIONS Despite a reduction in inter-laboratory variability for some proteins, different analytical systems showed both proportional and constant bias between methods. Units used by participants have not been substantially changed and dL is still largely used. The CRB EQA Program, with its performance data sets, is a valuable resource for laboratories and IVD manufacturers and support the goals of harmonization.
Collapse
|
3
|
Secchiero S, Sciacovelli L, Plebani M. Harmonization of units and reference intervals of plasma proteins: state of the art from an External Quality Assessment Scheme. ACTA ACUST UNITED AC 2018; 57:95-105. [DOI: 10.1515/cclm-2017-1172] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 04/03/2018] [Indexed: 01/29/2023]
Abstract
Abstract
Background:
The need to harmonize laboratory information is particularly intense in the field of plasma proteins, considering their clinical impact and relevance in monitoring diseases.
Methods:
We evaluated units and reference intervals (RIs) utilized by participants of the External Quality Assessment Scheme (EQAS) for plasma proteins of the Centre of Biomedical Research. Moreover, we evaluated inter-laboratory analytical variability from 2001 to 2017.
Results:
The census of participants’ units employed in 2017 showed that for albumin (ALB), ~66% of laboratories still used dL instead of L, and for most other proteins, ~70% still expressed the results in mg/dL. Laboratories primarily used the RIs reported in the packaging inserts of their analytical systems, but for each protein, there was a wide variability of RIs, also among laboratories using the same analytical method. Mean CVs% of the 13 certified proteins in the last five EQA cycles ranged from 3.8% of haptoglobin (HPT) to 12.4% of α1-antitrypsin (AAT) and decreased from 2001 to 2017 for most of them, in particular for C3, ALB, α2-macroglobulin (A2M), HPT and transferrin (TRF).
Conclusions:
In the face of a reduction in inter-laboratory variability for a lot of proteins, there has not been a substantial change in the units and in the RIs used by the participants. To change old habits is difficult and requires coordination and collaboration. The EQAS plays an important role in the assessment and monitoring of all elements that contribute to the formulation of laboratory information and may be useful to contribute to their harmonization.
Collapse
Affiliation(s)
- Sandra Secchiero
- Centre of Biomedical Research – Department of Laboratory Medicine , University-Hospital of Padova , Via Giustiniani, 2 , 35128 Padova , Italy , Phone: +39-049-821-4490, Fax: +39-049-821-7916
| | - Laura Sciacovelli
- Centre of Biomedical Research , University-Hospital of Padova , Padova , Italy
| | - Mario Plebani
- Centre of Biomedical Research , University-Hospital of Padova , Padova , Italy
- Department of Laboratory Medicine , University-Hospital of Padova , Padova , Italy
| |
Collapse
|
4
|
Scholl PF, Cole RN, Ruczinski I, Gucek M, Diez R, Rennie A, Nathasingh C, Schulze K, Christian P, Yager JD, Groopman JD, West KP. Maternal serum proteome changes between the first and third trimester of pregnancy in rural southern Nepal. Placenta 2012; 33:424-32. [PMID: 22385826 DOI: 10.1016/j.placenta.2012.02.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 01/19/2012] [Accepted: 02/08/2012] [Indexed: 10/28/2022]
Abstract
Characterization of normal changes in the serum proteome during pregnancy may enhance understanding of maternal physiology and lead to the development of new gestational biomarkers. In 23 Nepalese pregnant women who delivered at term, two-dimensional difference in-gel electrophoresis (DIGE) was used to assess changes in relative protein abundance between paired serum samples collected in the first and third trimesters. One-hundred and forty-five of over 700 protein spots in DIGE gels (pI 4.2-6.8) exhibited nominally significant (p < 0.05) differences in abundance across trimesters. Additional filtering using a Bonferroni correction reduced the number of significant (p < 0.00019) spots to 61. Mass spectrometric analysis detected 38 proteins associated with gestational age, cytoskeletal remodeling, blood pressure regulation, lipid and nutrient transport, and inflammation. One new protein, pregnancy-specific β-glycoprotein 4 was detected. A follow-up isotope tagging for relative and absolute quantitation (iTRAQ) experiment of six mothers from the DIGE study revealed 111 proteins, of which 11 exhibited significant (p < 0.05) differences between trimesters. Four of these proteins: gelsolin, complement C1r subcomponent, α-1-acid glycoprotein, and α-1B-glycoprotein also changed in the DIGE analysis. Although not previously associated with normal pregnancy, gelsolin decreased in abundance by the third trimester (p < 0.01) in DIGE, iTRAQ and Western analyses. Changes in abundance of proteins in serum that are associated with syncytiotrophoblasts (gelsolin, pregnancy-specific β-1 glycoprotein 1 and β-2-glycoprotein I) probably reflect dynamics of a placental proteome shed into maternal circulation during pregnancy. Measurement of changes in the maternal serum proteome, when linked with birth outcomes, may yield biomarkers for tracking reproductive health in resource poor settings in future studies.
Collapse
Affiliation(s)
- P F Scholl
- Johns Hopkins University, Bloomberg School of Public Health, Department of Environmental Health Sciences, 615 N. Wolfe St., Baltimore, MD 21205-2200, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Ledue TB, Collins MF. Development and validation of 14 human serum protein assays on the Roche cobas® c 501. J Clin Lab Anal 2011; 25:52-60. [PMID: 21254244 DOI: 10.1002/jcla.20430] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Many laboratories rely on dedicated nephelometers and turbidimeters for the measurement of serum proteins. There are, however, a number of chemistry analyzers that offer open channel configurations for end-user applications. We developed and validated 14 human serum protein assays (α(1)-antitrypsin, α(2)-macroglobulin, albumin, apolipoproteins AI and B, complement components 3 and 4, haptoglobin, immunoglobulins A, G, and M, orosomucoid, transferrin, and transthyretin) on the Roche cobas(®) c 501. We obtained excellent precision at low, normal, and high physiologic concentrations of each protein (within-run imprecision CVs ≤2.5%, total imprecision CVs ≤3.6%). Linearity for each method was within 5% of the expected value throughout the calibration range, and method comparison studies to commercial assays from Roche or Siemens were in good agreement (r>0.975). We observed no significant interference from bilirubin (up to 414 mg/l), hemoglobin (up to 8.9 g/l), triglyceride (up to 28 g/l), or rheumatoid factor (up to 3,930 IU/ml). Calibration was stable for at least 14 days. The instrument's small reaction cell allowed us to conserve nearly 60% of our specimen and reagent volume compared with our previous system. These newly developed assays provide precise and accurate results with high throughput, but without the associated cost of a dedicated instrument.
Collapse
Affiliation(s)
- Thomas B Ledue
- Foundation for Blood Research, Scarborough, Maine 04074, USA.
| | | |
Collapse
|
6
|
Infusino I, Braga F, Valente C, Panteghini M. Commutability of the ERM-DA470k Reference Material for two assays measuring serum albumin using immunochemical principles. Clin Chem Lab Med 2011; 49:1383-1384. [DOI: 10.1515/cclm.2011.619] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
7
|
Standardizing plasma protein measurements worldwide: a challenging enterprise. Clin Chem Lab Med 2010; 48:1567-75. [DOI: 10.1515/cclm.2010.314] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
8
|
Standardization of ceruloplasmin measurements is still an issue despite the availability of a common reference material. Anal Bioanal Chem 2009; 397:521-5. [PMID: 19921156 DOI: 10.1007/s00216-009-3248-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2009] [Revised: 10/15/2009] [Accepted: 10/16/2009] [Indexed: 10/20/2022]
Abstract
The purpose of measurement standardization is to achieve closer comparability of results obtained using different commercial systems. Regarding serum protein immunoassays, a reference preparation (BCR-470) was released in 1993 and adopted by manufacturers across the world to value-assign their assay calibrators for routine methods to reduce method-dependent variation. Moving from nephelometric (Beckman Immage 800) to turbidimetric determination (Roche Cobas c 501) of seven serum proteins, we preliminarily checked the comparability of results between the two systems. The study was performed according to the CLSI EP9-A protocol on 30 fresh sera, tested on each system in duplicate, and subdivided on two different days, without recalibration and using manufacturers' control materials to validate the runs. Both manufacturers' package inserts provide statements that kit calibrators are traceable to BCR-470. Suggested reference intervals are also the same. Although a fairly good correlation was observed (r = 0.955), the comparison of ceruloplasmin methods produced evidence of highly significant proportional (regression slope, 0.572) and constant bias (intercept, 0.05 g/L). Absolute and percentage mean differences were -0.11 g/L (95% confidence interval (CI) -0.13 to -0.10 g/L) and -39.1% (CI -43.1 to -35.2%), respectively. No other evaluated proteins showed similar problems. Lacking a ceruloplasmin reference method, it is impossible to demonstrate that one of the two assays produces true ceruloplasmin values. The problem is, however, that results coming from the two assays are clearly not comparable. This may be either due to a lack of commutability of the reference material with biological samples in the evaluated assays or to calibration problems by manufacturers in one of the stages of the calibration hierarchy.
Collapse
|
9
|
Mak CM, Lam CW. Diagnosis of Wilson's disease: a comprehensive review. Crit Rev Clin Lab Sci 2008; 45:263-90. [PMID: 18568852 DOI: 10.1080/10408360801991055] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Wilson's disease is an autosomal recessive disorder of copper metabolism. The culprit gene is ATP7B. The worldwide prevalence is about 1 in 30,000, which may vary by population. Higher prevalence rates were reported using more sensitive screening techniques and pilot population screening. Typical presentations include neuropsychiatric and hepatic dysfunction, whereas atypical presentations are protean. Diagnosis relies on a high clinical suspicion, typical neurological symptoms, presence of Kayser-Fleischer rings, and reduced serum ceruloplasmin concentration. The conventional value of < 0.20 g/l is not a universal diagnostic value. Age of the subjects and analytical variations should be considered when interpreting these levels. Patients with inconclusive findings require further investigations such as 24 h urinary free-copper excretion, penicillamine challenge test, liver copper measurement, and detection of gene mutations. Direct molecular diagnosis remains the most decisive tool. Other tests such as non-ceruloplasmin-bound copper are unreliable. Potential pitfalls and limitations of these diagnostic markers are critically reviewed in this paper. The mainstays of therapy are trientine, penicillamine, and/or zinc. Liver transplantation is lifesaving for those with advanced disease. Ceruloplasmin oxidase activity and serum free-copper concentration should be monitored in patients on long-term de-coppering therapy to prevent iatrogenic copper deficiency.
Collapse
Affiliation(s)
- Chloe M Mak
- Department of Chemical Pathology, The Chinese University of Hong Kong, Hong Kong SAR, China.
| | | |
Collapse
|
10
|
Mak CM, Lam CW, Tam S. Diagnostic accuracy of serum ceruloplasmin in Wilson disease: determination of sensitivity and specificity by ROC curve analysis among ATP7B-genotyped subjects. Clin Chem 2008; 54:1356-62. [PMID: 18556333 DOI: 10.1373/clinchem.2008.103432] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND A serum ceruloplasmin concentration below 0.20 g/L is conventionally considered as one of the major diagnostic criteria for Wilson disease. This decision threshold has not been fully validated for its diagnostic characteristics, however. In this study, we evaluated various decision thresholds of serum ceruloplasmin concentration in the diagnosis of Wilson disease based on genotype-verified Wilson disease patients, carriers, and normal individuals. METHODS Serum ceruloplasmin concentration was measured by a nephelometric method in 57 Wilson disease patients and 71 family members (49 heterozygotes and 22 wild-type homozygotes), a validation group of 25 subjects clinically suspected of Wilson disease, and 690 normal individuals. We performed ROC analysis using Analyze-it software and confirmed the genotypes by direct DNA sequencing of ATP7B. RESULTS Serum ceruloplasmin concentrations <0.20, 0.14, and 0.10 g/L showed positive predictive values of 48.3%, 100%, and 100%, respectively, and negative predictive values of 98.7%, 97.1%, and 91.9%. In the validation group, a serum ceruloplasmin threshold of 0.14 g/L rendered 100% sensitivity and specificity. Forty of 690 healthy subjects had serum ceruloplasmin concentrations <0.20 g/L; however, these 40 individuals had normal genotypes by DNA sequencing, and none of the 40 had ceruloplasmin concentrations <0.14 g/L. CONCLUSIONS The diagnostic accuracy for Wilson disease using a serum ceruloplasmin concentration of 0.14 g/L as the local decision threshold was better than that using a threshold of 0.20 g/L. We suggest that laboratories providing ceruloplasmin assays determine decision thresholds based on local populations.
Collapse
Affiliation(s)
- Chloe M Mak
- Department of Chemical Pathology, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
| | | | | |
Collapse
|
11
|
Blirup-Jensen S, Johnson AM, Larsen M. Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material. Clin Chem Lab Med 2008; 46:1470-9. [DOI: 10.1515/cclm.2008.289] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
12
|
Semenova VA, Steward-Clark E, Stamey KL, Taylor TH, Schmidt DS, Martin SK, Marano N, Quinn CP. Mass value assignment of total and subclass immunoglobulin G in a human standard anthrax reference serum. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2005; 11:919-23. [PMID: 15358653 PMCID: PMC515271 DOI: 10.1128/cdli.11.5.919-923.2004] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
An anti-Anthrax Vaccine Adsorbed (anti-AVA) standard human reference serum pool, AVR414, has been prepared, and the total and protective antigen (PA)-specific immunoglobulin G (IgG) were quantified. AVR414 was prepared by plasmapheresis of healthy adults who had received a minimum of four subcutaneous injections of AVA. Mass values (in milligrams per milliliter) for total IgG and IgG subclasses 1 to 4 were determined by radial immunodiffusion. Anti-PA-specific IgG assignment (in micrograms per milliliter) was done by consensus of two complementary approaches: homologous enzyme-linked immunosorbent assay (ELISA) with affinity-purified anti-PA IgG as a calibrator and summation of mean PA-specific IgG subclass concentrations determined by IgG subclass-specific ELISA using the United States National Reference Preparation for Human Serum Proteins as a standard. The total IgG concentration assigned to AVR414 reference serum was 8.33 mg/ml. IgG subclass concentrations were the following: for IgG1, 4.48 mg/ml; for IgG2, 3.35 mg/ml; for IgG3, 0.37 mg/ml; and for IgG4, 0.30 mg/ml. The assigned mass value for total anti-PA-specific IgG was 141.2 microg/ml. Anti-PA-specific IgG subclass concentrations were the following: for IgG1, 79.6 microg/ml; for IgG2, 35.3 microg/ml; for IgG3, 3.2 microg/ml; and for IgG4, 25.3 microg/ml. Human reference serum pool AVR414 will have direct application in the standardization of anthrax serological assays, in reagent qualification, and as a standard for quantification of PA-specific IgG in humans who have been vaccinated with or otherwise exposed to Bacillus anthracis PA.
Collapse
Affiliation(s)
- V A Semenova
- Meningitis and Special Pathogens Branch, Division of Bacterial and Mycotic Diseases, Centers for Disease Control and Prevention, Atlanta, GA 30333, USA.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Macintyre G, Gutfreund KS, Martin WRW, Camicioli R, Cox DW. Value of an enzymatic assay for the determination of serum ceruloplasmin. ACTA ACUST UNITED AC 2005; 144:294-301. [PMID: 15614251 DOI: 10.1016/j.lab.2004.08.005] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The serum concentration of the copper protein ceruloplasmin has been an important diagnostic indicator of Wilson's disease (WD). It is widely quoted that 95% of people with WD have low serum ceruloplasmin concentrations. Current evidence suggests that a normal serum ceruloplasmin concentration is more common in patients with WD, particularly those with liver disease, perhaps in part because of the routine use of an immunologic assay. This assay might indicate a normal level of ceruloplasmin when the enzymatic activity is lower. Enzymatic activity is the biologically relevant parameter. We compared the immunologic measurement with the enzymatic assessment of oxidase activity in patients with liver or neurologic symptoms of unknown origin in whom WD was considered in the differential diagnosis. Although a strong correlation of ceruloplasmin protein concentration with oxidase activity was observed in controls, this was not the case for these patients. Twelve patients, presenting with various types of hepatic disease, demonstrated a weak correlation between ceruloplasmin protein concentration and oxidase activity. Ten percent of patients with neurologic symptoms ( n = 41) had low ceruloplasmin concentrations and oxidase activity, and another 8% had normal ceruloplasmin concentrations associated with low oxidase activity. Although the enzymatic method is preferred for its biologic relevance, ceruloplasmin analysis is not a reliable diagnostic parameter for the diagnosis of WD in patients with liver disease. An important use of the ceruloplasmin oxidase assay is in the follow-up of patients with WD. Ceruloplasmin oxidase activity was undetectable in sera from patients with WD who were undergoing long-term chelation therapy, suggesting an early sign of copper depletion and a need for subsequent monitoring for symptoms of copper deficiency.
Collapse
|
14
|
Johnson AM, Hyltoft Petersen P, Whicher JT, Carlström A, MacLennan S. Reference intervals for plasma proteins: similarities and differences between adult Caucasian and Asian Indian males in Yorkshire, UK. ACTA ACUST UNITED AC 2004; 42:792-9. [PMID: 15327015 DOI: 10.1515/cclm.2004.132] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractThe aim of this study was to investigate similarities and differences in the distribution of serum concentrations of nine proteins in two racial groups (Caucasian and Asian Indian) of adult males living in the same geographical area (Leeds, Bradford, UK) for at least two generations. This is part of a larger study to determine the need for separating reference intervals for racial and ethnic groups worldwide. The distributions of concentrations for all proteins evaluated in the Indians fit ln-Gaussian distributions, indicating probable homogeneity. However, for the Caucasians, the distributions for α
Collapse
Affiliation(s)
- A Myron Johnson
- Departments of Pediatrics (emeritus) and Obstetrics & Gynecology, University of North Carolina School of Medicine, Chapel Hill, NC, USA.
| | | | | | | | | |
Collapse
|
15
|
Ledue TB, Rifai N. Preanalytic and analytic sources of variations in C-reactive protein measurement: implications for cardiovascular disease risk assessment. Clin Chem 2003; 49:1258-71. [PMID: 12881440 DOI: 10.1373/49.8.1258] [Citation(s) in RCA: 165] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND C-reactive protein (CRP) is a widely recognized indicator of inflammation and is known to play an important role in atherogenesis. Recent prospective studies have demonstrated that increased CRP concentrations within the reference interval are a strong predictor of myocardial infarction, stroke, sudden cardiac death, and peripheral vascular disease in apparently healthy adults. On the basis of available evidence, the American Heart Association and the CDC have issued guidelines for the utility of CRP in the primary prevention of coronary heart disease and in patients with stable coronary disease or acute coronary syndromes. Nevertheless, there remains considerable work to optimize the utility of this marker for risk assessment. ISSUES Most traditional CRP tests designed to monitor acute and chronic inflammation have inadequate sensitivity for risk stratification of coronary disease. Thus, manufacturers have had to develop tests with higher sensitivity. Because an individual's CRP concentration will be interpreted according to fixed cut-points, issues related to the preanalytic and analytic components of CRP measurement must be considered and standardized where possible to avoid potential misclassification of cardiovascular risk. CONCLUSIONS Efforts to define performance criteria for high-sensitivity CRP applications coupled with growing awareness of the physiologic aspects of CRP most likely will lead to refinements in standardization, improved performance in quality-assessment schemes, and enhanced risk prediction.
Collapse
Affiliation(s)
- Thomas B Ledue
- Foundation for Blood Research, 69 U.S. Route One, Scarborough, ME 04070-0190, USA.
| | | |
Collapse
|
16
|
Johnson AM, Ledue TB, Collins MF. Commutability of the CRM 470 C-reactive protein value in the Dade Behring N High Sensitivity CRP assay. Clin Chem Lab Med 2003; 41:177-82. [PMID: 12667004 DOI: 10.1515/cclm.2003.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Certified Reference Material 470 (CRM 470) demonstrates commutability with both the manufacturer's calibrator and with dilutions of serum pools in the Dade Behring N High Sensitivity assay for C-reactive protein (CRP). Both regression and back calibration show similar nonlinearity for all materials, largely due to the method of calibration curve fitting used in this assay. Significant differences in values among the currently available commercial assays can be largely overcome by using appropriate calibration curve fitting and the recommended value transfer protocol, which includes a minimum of two assay runs on each of at least 3 separate days, with weight correction of all reconstitutions and dilutions. An initial weight-corrected dilution should be made each day because of the relatively high level of CRP in CRM 470. In our opinion, the degree of nonlinearity, imprecision, and differences in values in currently available assays renders the use of fixed clinical decision cut-points questionable for high-sensitivity CRP. An alternative approach is suggested.
Collapse
Affiliation(s)
- A Myron Johnson
- University of North Carolina School of Medicine, Chapel Hill, NC, USA.
| | | | | |
Collapse
|
17
|
Johnson AM, Whicher JT. Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe. Clin Chem Lab Med 2001; 39:1123-8. [PMID: 11831627 DOI: 10.1515/cclm.2001.177] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The introduction of the international reference material for serum proteins, CRM 470, has resulted in significant reduction of the among-laboratory variance for most proteins assayed in European national quality assurance programs. In general, the CVs have decreased by 5 to 65%. However, both among- and within-manufacturer variances in many cases remain unacceptably high. In addition, concentration-dependent differences in variance and bias are present for some proteins. Although some variance will persist, reducing variance and bias to levels required for the institution of universal reference ranges will necessitate more accurate transfer of values to calibrants and controls and improved calibration curve fitting by manufacturers, as well as better quality control within laboratories.
Collapse
Affiliation(s)
- A M Johnson
- Department of Pediatrics, University of North Carolina, Chapel Hill, USA.
| | | |
Collapse
|
18
|
Petersen PH, Whicher JT, Johnson AM, Itoh Y, Carlström AB. Strategy for determining racial and environmental similarities and differences for plasma proteins. Clin Chem Lab Med 2001; 39:1146-53. [PMID: 11831631 DOI: 10.1515/cclm.2001.181] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The aim of this protocol is to establish a common basis for the production of reference values and well-defined and documented reference intervals for plasma proteins, based on common standardization, using the IFCC/BCR/CAP Certified Reference Material CRM 470. The strategy is to search for racial and environmental/geographical similarities and sources of differences in order to describe the main causes for variability among smaller or larger groups in selected societies and to estimate the sizes of differences for the different proteins according to the investigated sources. For this purpose, groups of reference individuals are selected according to race and geographical/environmental location, e.g. African Americans and Caucasians from the US. The reference individuals are groups of approximately 160 healthy male blood donors, 20 to 60 years of age. Rule-out criteria are positivity for HIV, hepatitis B and C antibodies and blood hemoglobin below the lower reference limit. Exclusion in relation to different C-reactive protein (CRP) levels will be investigated. Coagulation, storage conditions, transport, and the procedure for thawing are specified. The laboratories undertaking the measurements must have adequate analytical performance, and calibration and quality of performance are defined and documented, together with recommended control materials and procedures. Statistical models for describing distributions and for comparing groups are described. It is recommended that the data be presented as reference limits with 90% confidence intervals of those limits.
Collapse
Affiliation(s)
- P H Petersen
- Department of Clinical Biochemistry, Odense University Hospital, Denmark.
| | | | | | | | | |
Collapse
|
19
|
Ledue TB, Johnson AM. Commutability of serum protein values: persisting bias among manufacturers using values assigned from the certified reference material 470 (CRM 470) in the United States. Clin Chem Lab Med 2001; 39:1129-33. [PMID: 11831628 DOI: 10.1515/cclm.2001.178] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Significant among-manufacturer differences in values for serum proteins persist 7 years after the introduction of the international reference material (Certified Reference Material 470; Reference Preparation for Proteins in Human Serum). In some cases, such as transthyretin and C4, the biases actually continue to increase. Further efforts at standardization are needed in order to improve commutability of results among laboratories and are essential if universal reference intervals are to be developed.
Collapse
Affiliation(s)
- T B Ledue
- Foundation for Blood Research, Scarborough, ME 04070-0190, USA.
| | | |
Collapse
|
20
|
Ledue TB, Rifai N. High sensitivity immunoassays for C-reactive protein: promises and pitfalls. Clin Chem Lab Med 2001; 39:1171-6. [PMID: 11831635 DOI: 10.1515/cclm.2001.185] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
C-reactive protein (CRP) has historically been measured in the clinical laboratory for the detection and monitoring of occult infection and inflammation, using immunoturbidimetric or immunonephelometric techniques. The recent commercial availability of automated high-sensitivity assays has enabled investigators to measure CRP at levels previously unattainable on a routine basis and to explore its clinical utility in apparently healthy individuals. CRP concentrations increased above the individuals' baselines but still within the normal reference intervals have been observed in association with increasing age, obesity, and smoking and in individuals with chronic infections such as Chlamydia pneumoniae and Helicobacter pylori. More importantly, however, data from prospective studies have shown CRP to be a strong and independent predictor of future coronary events in subjects with and without coronary heart disease. An algorithm for risk assessment of coronary risk employing both CRP and lipid concentrations has recently been proposed. However, in order for this approach to be incorporated into clinical practice, agreement among the various CRP methods must be achieved. Of critical importance to this process is a basic understanding of issues affecting assay performance. Factors such as assay precision, sensitivity, matrix effects, calibration, and standardization need to be addressed adequately by the in vitro diagnostic industry and the clinical laboratory.
Collapse
Affiliation(s)
- T B Ledue
- Foundation for Blood Research, Scarborough, ME 04070-0190, USA.
| | | |
Collapse
|
21
|
Palomaki GE, Neveux LM. Using multiples of the median to normalize serum protein measurements. Clin Chem Lab Med 2001; 39:1137-45. [PMID: 11831630 DOI: 10.1515/cclm.2001.180] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Quantification of serum proteins is useful in the diagnosis and clinical management of many disorders. With the introduction of automated analyzers and standardized reference materials, one of the last barriers to more widespread utilization of these measurements is the lack of availability of reliable and transferable age- and gender-specific reference ranges. One normalization method that deserves consideration is converting values to multiples of the median (MoM) for age and gender. When two analytic methods agree, or differ only by a proportional amount, conversion to MoM can be used to simplify the clinical interpretation of serum protein results. As a test of this method, assay results for IgG, transferrin, and albumin from three Swedish hospitals were normalized using published reference ranges from the United States. All assays were standardized to CRM 470. IgG results were in agreement in mass units, and transferrin measurements were proportionally different. However, there were important, non-proportional differences in albumin measurements. After converting IgG and transferrin measurements to MoM, published reference ranges were appropriate for the Swedish Hospitals.
Collapse
Affiliation(s)
- G E Palomaki
- Foundation for Blood Research, Scarborough, Maine 04038, USA.
| | | |
Collapse
|
22
|
Blirup-Jensen S, Johnson AM, Larsen M. Protein standardization IV: Value transfer procedure for the assignment of serum protein values from a reference preparation to a target material. Clin Chem Lab Med 2001; 39:1110-22. [PMID: 11831626 DOI: 10.1515/cclm.2001.176] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A new approach for the assignment of values to serum proteins in a target material using a reference preparation has been developed. The procedure describes the general as well as the practical principles involved in the value assignment (with examples). Two models have been developed: 1) The direct value transfer between serum matrices and 2) the indirect value transfer from a pure protein preparation to a serum protein material. The necessary mathematical equations are developed and explained. The data reduction and statistical evaluation are discussed. The practical procedure (the transfer protocol) is based on six dilutions of the reference preparation assayed together with six dilutions of the target material. In this way imprecision is reduced and the proportionality of the two materials (i.e. the presence or absence of matrix effects) can be assessed directly by evaluating a single regression plot. If no matrix effects are found, the regression line will pass through zero with a slope equal to the ratio of the concentrations of the two materials. The transfer protocol is based on a multiple point value assignment obtained by several measurements a day repeated on several days, an important prerequisite being that all reconstitutions and dilutions are controlled by weighing.
Collapse
Affiliation(s)
- S Blirup-Jensen
- Clinical Immunochemistry and Microbiology, DAKO A/S, Copenhagen, Denmark.
| | | | | |
Collapse
|