1
|
Mularska W, Wróblewska-Zierhoffer M, Adamski W, Rospond-Kubiak I. Surgical outcomes of unwrapped acrylic orbital implants: A review of 192 patients. J Fr Ophtalmol 2023; 46:1149-1154. [PMID: 37679221 DOI: 10.1016/j.jfo.2023.03.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/28/2023] [Accepted: 03/14/2023] [Indexed: 09/09/2023]
Abstract
PURPOSE The purpose of this study is to report the results in a series of acrylic orbital implant placements without the use of wrapping material. METHODS We retrospectively reviewed the records of the patients who underwent enucleation with acrylic orbital implant insertion without scleral wrapping at the Department of Ophthalmology, Poznań University of Medical Sciences, Poland, between 2013 and 2020. RESULTS There were 192 patients: 102 women and 90 men, mean age: 60 years (range: 13-90 years). In the majority of cases, the reason for enucleation was uveal melanoma (148 patients-77.1%), followed by secondary glaucoma in 22 patients (11.5%) and painful, phthisical eye in 16 (8.3%). The median follow-up was 23 months (range: 1-96 months). The stability of the implants was satisfactory in the majority of cases, and there were no cases of implant migration identified during the study period. We noted a total of 4 (2%) implant exposures. Other postoperative complaints included eyelid malposition-21 patients (11%), Tenon's capsule thinning (15 patients-7.8%) and post-enucleation eye socket syndrome (PEES)-7 patients (3.6%). The rate of postoperative complications was associated only with a history of previous ocular surgery (P=0.006). CONCLUSIONS The stability and functional outcomes of unwrapped acrylic orbital implants in this group of patients were satisfactory during the follow-up period.
Collapse
Affiliation(s)
- W Mularska
- Department of Ophthalmology, Poznań University of Medical Sciences, 84/82, Szamarzewskiego Street, 61-848 Poznań, Poland
| | - M Wróblewska-Zierhoffer
- Department of Ophthalmology, Poznań University of Medical Sciences, 84/82, Szamarzewskiego Street, 61-848 Poznań, Poland
| | - W Adamski
- Department of Ophthalmology, Poznań District Hospital, 7/19 Juraszów Street, 60-479 Poznań, Poland
| | - I Rospond-Kubiak
- Department of Ophthalmology, Poznań University of Medical Sciences, 84/82, Szamarzewskiego Street, 61-848 Poznań, Poland.
| |
Collapse
|
2
|
Zhao H, Chen Y, Zheng Y, Xu J, Zhang C, Fu M, Xiong K. Conjunctival sac microbiome in anophthalmic patients: Flora diversity and the impact of ocular prosthesis materials. Front Cell Infect Microbiol 2023; 13:1117673. [PMID: 36960044 PMCID: PMC10027910 DOI: 10.3389/fcimb.2023.1117673] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 02/09/2023] [Indexed: 03/09/2023] Open
Abstract
Purpose To explore the changes of bacterial flora in anophthalmic patients wearing ocular prosthesis (OP) and the microbiome diversity in conditions of different OP materials. Methods A cross-sectional clinical study was conducted, involving 19 OP patients and 23 healthy subjects. Samples were collected from the upper, lower palpebral, caruncle, and fornix conjunctiva. 16S rRNA sequencing was applied to identify the bacterial flora in the samples. The eye comfort of each OP patient was determined by a questionnaire. In addition, demographics information of each participant was also collected. Results The diversity and richness of ocular flora in OP patients were significantly higher than that in healthy subjects. The results of flora species analysis also indicated that in OP patients, pathogenic microorganisms such as Escherichia Shigella and Fusobacterium increased significantly, while the resident flora of Lactobacillus and Lactococcus decreased significantly. Within the self-comparison of OP patients, compared with Polymethyl Methacrylate (PMMA), prosthetic material of glass will lead to the increased colonization of opportunistic pathogens such as Alcaligenes, Dermabacter and Spirochaetes, while gender and age have no significant impact on ocular flora. Conclusions The ocular flora of OP patients was significantly different from that of healthy people. Abundant colonization of pathogenic microorganisms may have an important potential relationship with eye discomfort and eye diseases of OP patients. PMMA, as an artificial eye material, demonstrated potential advantages in reducing the colonization of opportunistic pathogens.
Collapse
Affiliation(s)
- Hejia Zhao
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- School of Public Health, Southern Medical University, Guangzhou, Guangdong, China
| | - Yanjun Chen
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Yixu Zheng
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Jing Xu
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Chenyu Zhang
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- School of Public Health, Southern Medical University, Guangzhou, Guangdong, China
| | - Min Fu
- Department of Ophthalmology, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- *Correspondence: Ke Xiong, ; Min Fu,
| | - Ke Xiong
- Department of Ophthalmology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- *Correspondence: Ke Xiong, ; Min Fu,
| |
Collapse
|
3
|
Muacevic A, Adler JR. An Orbital Mystery: A Unique Case of an Obsolete Orbital Implant With a Review of Orbital Implant Materials. Cureus 2022; 14:e30215. [PMID: 36381938 PMCID: PMC9650925 DOI: 10.7759/cureus.30215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/12/2022] [Indexed: 11/29/2022] Open
Abstract
Orbital implant materials have evolved greatly over the past century and include but are not limited to metal, ceramic, polymer, silicone, and glass. Knowledge of historically used materials is clinically relevant to patient care as certain materials carry a greater risk of migration, extrusion, infection, and limitations for imaging modalities utilized to visualize adjacent structures. We report an unusual case of an 80-year-old male who presented to our community hospital with seizure-like activity. CT imaging of the brain revealed several white matter and cortex lesions with the largest lesion measuring 2.5 × 2 × 1.9 cm. The patient had a history of enucleation with placement of an orbital implant following a penetrating injury to the left eye at four years of age. Hounsfield scale analysis was read by radiology as being most consistent with a thin metallic shell surrounding the orbital implant. The potential for metallic material was consistent with the implant's age and time of placement. Few reviews on ocular implant materials from this period exist in the current medical literature. A single case report discussing a hollow metal orbital implant with similar-appearing imaging was identified. Due to concern for possible metal implant materials, the patient underwent implant exchange so MRI imaging could safely be performed. Intraoperatively, the implant was identified as a clear, hollow, non-metallic, non-porous polymer sphere. Following surgery, the patient was able to undergo appropriate neuroimaging with subsequent diagnostic biopsy. Current literature reviewing CT or photographic imaging of ocular implant devices prior to the 1940s is limited. This case highlights the importance of detailing materials historically used in orbital implants, their effects on clinical decision-making, and the utility of Hounsfield scale values to identify a material's radiodensity on CT imaging.
Collapse
|
4
|
The Anatomic Classification of the Anophthalmic Eye Socket (Type 0-V): A high level taxonomy classification system. J Plast Reconstr Aesthet Surg 2022; 75:3491-3498. [DOI: 10.1016/j.bjps.2022.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 04/18/2022] [Accepted: 06/06/2022] [Indexed: 11/17/2022]
|
5
|
AlSubaie MF, Al-Sharydah AM, Nassim HM, Alhawsawi A. Orbital Floor Blowout Fracture Reconstruction Using Moldable Polymethyl Methacrylate: A Report of Two Cases and Their Imaging Findings. OPEN ACCESS EMERGENCY MEDICINE 2022; 14:223-232. [PMID: 35656329 PMCID: PMC9153998 DOI: 10.2147/oaem.s359173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 05/13/2022] [Indexed: 11/23/2022] Open
Abstract
Background Blowout fracture is defined as an internal orbital fracture that does not involve the orbital rim. This type of fracture results in the loss of tissue and disruption of the structure of the orbital wall. The symptoms and signs include pain, enophthalmos, diplopia, orbital emphysema, and ecchymosis. The surgeon’s main goal is to reconstruct the orbit in the best possible manner to achieve optimal anatomy and functionality of the orbit wall postoperatively. There is no consensus regarding the best material for use in surgical orbital reconstruction, despite the commercial availability of several biological and manufactured materials. Moreover, material selection is often based on the practitioner’s preferences/experience and patient safety. This study reported two cases of orbital fracture reconstruction using moldable methyl polymethacrylate as a bone surrogate. This material has already been used in dentistry, neurosurgery, and orthopedic surgery and is potentially hazard-free for orbit surgery. Case Presentation Two victims of motor vehicle collisions presented with blowout orbital fractures. Cross-sectional imaging revealed inferior fractures involving the orbital wall. High-resolution tomographic modeling was used to plan surgical orbital floor reconstruction using moldable polymethyl methacrylate material. The short-term outcome of the implant appeared favorable at the one-year follow-up, based on regular patient monitoring and cross-sectional imaging assessment. Postoperative improvement with positive clinical outcomes was observed during both patients’ follow-up visits. Conclusion Moldable polymethyl methacrylate can be used safely and effectively for reconstructive surgeries for the management of blowout orbital fractures. This new technique ensured a satisfactory short-term postoperative orbital configuration and tolerance and good esthetic and functional results without adverse effects. This customizable product is affordable and easy to fabricate.
Collapse
Affiliation(s)
- Majed Fehaid AlSubaie
- Department of Ophthalmology, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Khobar City, Eastern Province, Saudi Arabia
- Department of Ophthalmology, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran City, Eastern Province, Saudi Arabia
- Correspondence: Majed Fehaid AlSubaie, Department of Ophthalmology, Dhahran-Eye-Specialist-Hospital, Al Jamiah, Dhahran City, Eastern Province, Saudi Arabia, P.O. Box: 31952, Email
| | - Abdulaziz Mohammad Al-Sharydah
- Department of Diagnostic and Interventional Radiology, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Khobar City, Eastern Province, Saudi Arabia
| | - Hala M Nassim
- Department of Ophthalmology, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Khobar City, Eastern Province, Saudi Arabia
| | - Abrar Alhawsawi
- Department of Ophthalmology, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Khobar City, Eastern Province, Saudi Arabia
- College of Medicine, Ophthalmology Department, Jeddah University, Jeddah, Saudi Arabia
| |
Collapse
|
6
|
Abstract
The ideal implant for anophthalmic socket reconstruction has yet to be developed. Biosilicate, a highly bioactive glass-ceramic, has been used in the composition of conical implants, which were initially tested in rabbit orbits with excellent results. However, the use of this material and the conical shape of the implants require further study in the human anophthalmic socket. Thus, we propose the use of a new conical implant composed of Biosilicate for orbital volume augmentation in anophthalmic sockets. This prospective, randomized study included 45 patients receiving conical implants composed of either Biosilicate or polymethylmethacrylate (control). Patients were evaluated clinically before and 7, 30, 60, 120, and 180 days after implantation. Systemic evaluations, laboratory tests, and computed tomography of the orbits were performed preoperatively and 180 days postoperatively. Both groups had good outcomes with no significant infectious or inflammatory processes. Only 1 patient, in the Biosilicate group, had early implant extrusion. Laboratory tests were normal in both groups. Computed tomography scans showed that the implants in both groups were well positioned. The new conical implant composed of Biosilicate was successfully used for anophthalmic socket reconstruction. This implant may provide a good alternative to the only conical implant currently available on the market, which is composed of porous polyethylene.
Collapse
|
7
|
Jeyabal P, Sundar G. Anophthalmic Sockets in Retinoblastoma: A Single Center Experience. Asia Pac J Ophthalmol (Phila) 2018; 7:307-311. [PMID: 30074308 DOI: 10.22608/apo.201892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To evaluate outcomes of anophthalmic sockets in retinoblastoma at a tertiary care center in Singapore. DESIGN A retrospective study. METHODS Patients who underwent enucleation as sole/part of treatment for retinoblastoma were reviewed at our center from 2005-2017. Details including demographics, grouping and staging, adjuvant therapy, surgery, implant, and complications were collected. RESULTS Of 42 patients with retinoblastoma managed over the period, the anophthalmic sockets of 31 patients who underwent enucleation were analyzed. Mean age at enucleation was 2 years. Twenty-three enucleations were performed at our institution and 8 enucleations had been performed elsewhere. Seventeen patients (52%) had porous polypropylene, 9 patients (27%) had polymethylmethacrylate, 1 patient (3%) had glass implant, and 3 (9%) had dermis fat graft. The sizes of implants varied from 10 to 20 mm. Twelve patients had attempts at globe salvation before enucleation. Out of 28 patients with primary orbital implants, 3 had implant exposure. The rates of repeat surgery among patients with and without primary implant were 66.67% (2 out of 3) and 10.7% (3 out of 28), respectively. One patient had postenucleation socket syndrome with stock eye. Five patients referred for enucleation were conservatively managed. CONCLUSIONS Anophthalmic sockets in retinoblastoma have long-term implications if the primary procedure is not performed well. While the majority had good outcomes (structural and esthetic), a minority had complications requiring intervention. Ophthalmologists managing retinoblastoma must be aware of these. Primary implant had favorable outcome with minimal complications.
Collapse
Affiliation(s)
- Preethi Jeyabal
- Department of Ophthalmology, National University of Singapore, Singapore
| | - Gangadhara Sundar
- Department of Ophthalmology, National University of Singapore, Singapore
| |
Collapse
|
8
|
Maskey B, Mathema SRB, Shrestha K, Bhochhibhoya A. A Simplified Approach to Fabricate a Hollow Ocular Prosthesis. J Prosthodont 2018; 28:849-852. [PMID: 29322593 DOI: 10.1111/jopr.12757] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/27/2017] [Indexed: 11/29/2022] Open
Abstract
The prosthetic rehabilitation of a large anophthalmic socket is always a challenge. It demands an equally sized ocular prosthesis to replace lost tissue volume. A conventional solid acrylic ocular prosthesis may be deterrent to retention and esthetics because of its weight, which can be reduced by eliminating the mass of material within it. This article attempts to present a simplified and accurate technique to fabricate a hollow ocular prosthesis using silicone putty cavity form. It is removed prior to final processing and serves to ensure appropriate uniform thickness of acrylic resin and optimal weight reduction of the definitive prosthesis without compromising mobility, esthetics, and structural integrity.
Collapse
Affiliation(s)
- Brijesh Maskey
- Department of Prosthodontics and Maxillofacial Prosthetics, People's Dental College and Hospital, Kathmandu, Nepal
| | - Suraj R B Mathema
- Department of Prosthodontics and Maxillofacial Prosthetics, People's Dental College and Hospital, Kathmandu, Nepal
| | - Kanchana Shrestha
- Department of Prosthodontics and Maxillofacial Prosthetics, People's Dental College and Hospital, Kathmandu, Nepal
| | - Amar Bhochhibhoya
- Department of Prosthodontics and Maxillofacial Prosthetics, People's Dental College and Hospital, Kathmandu, Nepal
| |
Collapse
|
9
|
Abstract
An orbital defect causes severe facial asymmetry and disfigurement that result in an immense emotional trauma to the patient and is also associated with economic, esthetic, and psychological problems. A prosthetic replacement is the treatment of choice in helping individual to return to his normal life by producing an acceptable and lifelike appearance. This case report describes the critical areas of fabrication of ocular prosthesis for a patient with missing right eye due to trauma to eye ball in an accident. Patient had given a history of surgical enucleation of the eye 15 days after ocular trauma. A polymethyl methacrylate ocular prosthesis was planned. The technique described in this case report presents the use of both custom-made and stock eye shell in an attempt to include the benefits of both. A novel attempt was made to simulate eye movements and exact color matching to that of contralateral eye to provide a better and functional ocular prosthesis to the patient.
Collapse
Affiliation(s)
- Srinivasa B Rao
- Department of Maxillofacial Prosthodontics and Implantology, Gitams Dental College, Visakhapatnam, Andhra Pradesh, India
| | - Savita Akki
- Department of Dentistry, Bidar Institute of Medical Sciences, Bidar, Karnataka, India
| | - Deepak Kumar
- Department of Oral and Maxillofacial Surgery, Purvanchal Institute of Dental Sciences, Gorakhpur, Uttar Pradesh, India
| | - Sunil Kumar Mishra
- Department of Maxillofacial Prosthodontics and Implantology, Peoples College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India
| |
Collapse
|
10
|
Schellini S, El Dib R, Silva LR, Farat JG, Zhang Y, Jorge EC. Integrated versus non-integrated orbital implants for treating anophthalmic sockets. Cochrane Database Syst Rev 2016; 11:CD010293. [PMID: 27820878 PMCID: PMC6465188 DOI: 10.1002/14651858.cd010293.pub2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Anophthalmia is the absence of one or both eyes, and it can be congenital (i.e. a birth defect) or acquired later in life. There are two main types of orbital implant: integrated, whereby the implant receives a blood supply from the body that allows for the integration of the prosthesis within the tissue; and non-integrated, where the implant remains separate. Despite the remarkable progress in anophthalmic socket reconstruction and in the development of various types of implants, there are still uncertainties about the real roles of integrated (hydroxyapatite (HA), porous polyethylene (PP), composites) and non-integrated (polymethylmethacrylate (PMMA)/acrylic and silicone) orbital implants in anophthalmic socket treatment. OBJECTIVES To assess the effects of integrated versus non-integrated orbital implants for treating anophthalmic sockets. SEARCH METHODS We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2016), Embase (January 1980 to August 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to August 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 8 August 2016. SELECTION CRITERIA Randomised controlled trials (RCTs) and quasi-RCTs of integrated and non-integrated orbital implants for treating anophthalmic sockets. DATA COLLECTION AND ANALYSIS Two authors independently selected relevant trials, assessed methodological quality and extracted data. MAIN RESULTS We included three studies with a total of 284 participants (250 included in analysis). The studies were conducted in India, Iran and the Netherlands. The three studies were clinically heterogenous, comparing different materials and using different surgical techniques. None of the included studies used a peg (i.e. a fixing pin used to connect the implant to the prosthesis). In general the trials were poorly reported, and we judged them to be at unclear risk of bias.One trial compared HA using traditional enucleation versus alloplastic implantation using evisceration (N = 100). This trial was probably not masked. The second trial compared PP with scleral cap enucleation versus PMMA with either myoconjunctival or traditional enucleation (N = 150). Although participants were not masked, outcome assessors were. The last trial compared HA and acrylic using the enucleation technique (N = 34) but did not report comparative effectiveness data.In the trial comparing HA versus alloplastic implantation, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.95 to 1.09, N = 100, low-certainty evidence). People receiving HA had slightly worse horizontal implant mobility compared to the alloplastic group (mean difference (MD) -3.35 mm, 95% CI -4.08 to -2.62, very low-certainty evidence) and slightly worse vertical implant motility (MD -2.76 mm, 95% CI -3.45 to -2.07, very low-certainty evidence). As different techniques were used - enucleation versus evisceration - it is not clear whether these differences in implant motility can be attributed solely to the type of material. Investigators did not report adverse events.In the trial comparing PP versus PMMA, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (RR 0.92, 95% CI 0.84 to 1.01, N = 150, low-certainty evidence). There was very low-certainty evidence of a difference in horizontal implant motility depending on whether PP was compared to PMMA with traditional enucleation (MD 1.96 mm, 95% CI 1.01 to 2.91) or PMMA with myoconjunctival enucleation (-0.57 mm, 95% CI -1.63 to 0.49). Similarly, for vertical implant motility, there was very low-certainty evidence of a difference in the comparison of PP to PMMA traditional (MD 3.12 mm 95% CI 2.36 to 3.88) but no evidence of a difference when comparing PP to PMMA myoconjunctival (MD -0.20 mm 95% CI -1.28 to 0.88). Four people in the PP group (total N = 50) experienced adverse events (i.e. exposures) compared to 6/100 in the PMMA groups (RR 17.82, 95% CI 0.98 to 324.67, N = 150, very low-certainty evidence).None of the studies reported socket sphere size, cosmetic effect or quality of life measures. AUTHORS' CONCLUSIONS Current very low-certainty evidence from three small published randomised controlled trials did not provide sufficient evidence to assess the effect of integrated and non-integrated material orbital implants for treating anophthalmic sockets. This review underlines the need to conduct further well-designed trials in this field.
Collapse
Affiliation(s)
- Silvana Schellini
- Botucatu Medical School, UNESP - Univ Estadual Paulista, Distrito de Rubião Júnior, s/n, Botucatu, São Paulo, Brazil, 18618-970
| | | | | | | | | | | |
Collapse
|