1
|
Islam Anoy MM, Kim WJ, Gelston S, Fleming D, Patel R, Beyenal H. Evaluation of Treatment of Methicillin-Resistant Staphylococcus aureus Biofilms with Intermittent Electrochemically-Generated H 2O 2 or HOCl. bioRxiv 2024:2024.03.22.586337. [PMID: 38586004 PMCID: PMC10996509 DOI: 10.1101/2024.03.22.586337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
Chronic wound infections can be difficult to treat and may lead to impaired healing and worsened patient outcomes. Novel treatment strategies are needed. This study evaluated effects of intermittently produced H2O2 and HOCl, generated via an electrochemical bandage (e-bandage), against methicillin-resistant Staphylococcus aureus biofilms in an agar membrane biofilm model. By changing the working electrode potential, the e-bandage generated either HOCl (1.5 VAg/AgCl) or H2O2 (-0.6 VAg/AgCl). The degree of biocidal activity of intermittent treatment with HOCl and H2O2 correlated with HOCl treatment time; HOCl treatment durations of 0, 1.5, 3, 4.5, and 6 hours (with the rest of the 6 hour total treatment time devoted to H2O2 generation) resulted in mean biofilm reductions of 1.36±0.2, 2.22±0.16, 3.46±0.38, 4.63±0.74 and 7.66±0.5 log CFU/cm2, respectively vs. non-polarized controls, respectively. However, application of H2O2 immediately after HOCl treatment was detrimental to biofilm removal. For example, 3-hours HOCl treatment followed by 3-hours H2O2 resulted in a 1.90±0.84 log CFU/cm2 lower mean biofilm reduction than 3-hours HOCl treatment followed by 3-hours non-polarization. HOCl generated over 3-hours exhibited biocidal activity for at least 7.5-hours after e-bandage operation ceased; 3-hours of HOCl generation followed by 7.5-hours of non-polarization resulted in a biofilm cell reduction of 7.92±0.12 log CFU/cm2 vs. non polarized controls. Finally, intermittent treatment with HOCl (i.e., interspersed with periods of e-bandage non-polarization) for various intervals showed similar effects (approximately 6 log CFU/cm2 reduction vs. non-polarized control) to continuous treatment with HOCl for 3-hours, followed by 3-hours of non-polarization. These findings suggest that timing and sequencing of HOCl and H2O2 treatments are crucial for maximizing biofilm control.
Collapse
Affiliation(s)
- Md Monzurul Islam Anoy
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| | - Won-Jun Kim
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| | - Suzanne Gelston
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| | - Derek Fleming
- Division of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Robin Patel
- Division of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota 55905, USA
- Division of Public Health, Infectious Diseases, and Occupational Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| |
Collapse
|
2
|
Fleming D, Bozyel I, Koscianski CA, Ozdemir D, Karau MJ, Cuello L, Anoy MMI, Gelston S, Schuetz AN, Greenwood-Quaintance KE, Mandrekar JN, Beyenal H, Patel R. HOCl-producing Electrochemical Bandage is Active in Murine Polymicrobial Wound Infection. bioRxiv 2024:2024.03.19.585100. [PMID: 38562889 PMCID: PMC10983912 DOI: 10.1101/2024.03.19.585100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Wound infections, exacerbated by the prevalence of antibiotic-resistant bacterial pathogens, necessitate innovative antimicrobial approaches. Polymicrobial infections, often involving Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), present formidable challenges due to biofilm formation and antibiotic resistance. Hypochlorous acid (HOCl), a potent antimicrobial agent produced naturally by the immune system, holds promise as an alternative therapy. An electrochemical bandage (e-bandage) that generates HOCl in situ was evaluated for treatment of murine wound biofilm infections containing both MRSA and P. aeruginosa with "difficult-to-treat" resistance. Previously, the HOCl-producing e-bandage was shown to reduce wound biofilms containing P. aeruginosa alone. Compared to non-polarized e-bandage (no HOCl production) and Tegaderm only controls, the polarized e-bandages reduced bacterial loads in wounds infected with MRSA plus P. aeruginosa (MRSA: vs Tegaderm only - 1.4 log10 CFU/g, p = 0.0015, vs. non-polarized - 1.1 log10 CFU/g, p = 0.026. P. aeruginosa: vs Tegaderm only - 1.6 log10 CFU/g, p = 0.0015, vs non-polarized - 1.6 log10 CFU/g, p = 0.0032), and MRSA alone (vs Tegaderm only - 1.3 log10 CFU/g, p = 0.0048, vs. non-polarized - 1.1 log10 CFU/g, p = 0.0048), without compromising wound healing or causing tissue toxicity. Addition of systemic antibiotics did not enhance the antimicrobial efficacy of e-bandages, highlighting their potential as standalone therapies. This study provides additional evidence for the HOCl-producing e-bandage as a novel antimicrobial strategy for managing wound infections, including in the context of antibiotic resistance and polymicrobial infections.
Collapse
Affiliation(s)
- Derek Fleming
- Division of Clinical Microbiology, Mayo Clinic, Rochester, MN
| | - Ibrahim Bozyel
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA
| | | | - Dilara Ozdemir
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA
| | | | - Luz Cuello
- Division of Clinical Microbiology, Mayo Clinic, Rochester, MN
| | - Md Monzurul Islam Anoy
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA
| | - Suzanne Gelston
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA
| | | | | | | | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA
| | - Robin Patel
- Division of Clinical Microbiology, Mayo Clinic, Rochester, MN
- Division of Public Health, Infectious Diseases, and Occupational Medicine, Mayo Clinic, Rochester, MN
| |
Collapse
|
3
|
Fleming D, Bozyel I, Ozdemir D, Otero JA, Karau MJ, Anoy MMI, Koscianski C, Schuetz AN, Greenwood-Quaintance KE, Mandrekar JN, Beyenal H, Patel R. HOCl-producing electrochemical bandage for treating Pseudomonas aeruginosa-infected murine wounds. Antimicrob Agents Chemother 2024; 68:e0121623. [PMID: 38214514 PMCID: PMC10946410 DOI: 10.1128/aac.01216-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 11/25/2023] [Indexed: 01/13/2024] Open
Abstract
The growing threat of antibiotic-resistant bacterial pathogens necessitates the development of alternative antimicrobial approaches. This is particularly true for chronic wound infections, which commonly harbor biofilm-dwelling bacteria. A novel electrochemical bandage (e-bandage) delivering low-levels of hypochlorous acid (HOCl) was evaluated against Pseudomonas aeruginosa murine wound biofilms. 5 mm skin wounds were created on the dorsum of mice and infected with 106 colony-forming units (CFU) of P. aeruginosa. Biofilms were formed over 2 days, after which e-bandages were placed on the wound beds and covered with Tegaderm. Mice were administered Tegaderm-only (control), non-polarized e-bandage (no HOCl production), or polarized e-bandage (using an HOCl-producing potentiostat), with or without systemic amikacin. Purulence and wound areas were measured before and after treatment. After 48 hours, wounds were harvested for bacterial quantification. Forty-eight hours of polarized e-bandage treatment resulted in mean biofilm reductions of 1.4 log10 CFUs/g (P = 0.0107) vs non-polarized controls and 2.2 log10 CFU/g (P = 0.004) vs Tegaderm-only controls. Amikacin improved CFU reduction in Tegaderm-only (P = 0.0045) and non-polarized control groups (P = 0.0312) but not in the polarized group (P = 0.3876). Compared to the Tegaderm-only group, there was less purulence in the polarized group (P = 0.009). Wound closure was neither impeded nor improved by either polarized or non-polarized e-bandage treatment. Concurrent amikacin did not impact wound closure or purulence. In conclusion, an HOCl-producing e-bandage reduced P. aeruginosa in wound biofilms with no impairment in wound healing, representing a promising antibiotic-free approach for addressing wound infection.
Collapse
Affiliation(s)
- Derek Fleming
- Mayo Clinic, Division of Clinical Microbiology, Rochester, Minnesota, USA
| | - Ibrahim Bozyel
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | - Dilara Ozdemir
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | | | - Melissa J. Karau
- Mayo Clinic, Division of Clinical Microbiology, Rochester, Minnesota, USA
| | - Md Monzurul Islam Anoy
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | | | - Audrey N. Schuetz
- Mayo Clinic, Division of Clinical Microbiology, Rochester, Minnesota, USA
| | | | | | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | - Robin Patel
- Mayo Clinic, Division of Clinical Microbiology, Rochester, Minnesota, USA
- Division of Public Health, Infectious Diseases, and Occupational Medicine, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
4
|
Fleming D, Bozyel I, Ozdemir D, Otero JA, Karau MJ, Islam Anoy MM, Koscianski C, Schuetz AN, Greenwood-Quaintance KE, Mandrekar JN, Beyenal H, Patel R. HOCl-producing Electrochemical Bandages for Treating Pseudomonas aeruginosa -Infected Murine Wounds. bioRxiv 2023:2023.09.20.558698. [PMID: 37790575 PMCID: PMC10542532 DOI: 10.1101/2023.09.20.558698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/05/2023]
Abstract
A novel electrochemical bandage (e-bandage) delivering low-level hypochlorous acid (HOCl) was evaluated against Pseudomonas aeruginosa murine wound biofilms. 5 mm skin wounds were created on the dorsum of Swiss-Webster mice and infected with 10 6 colony forming units (CFU) of P. aeruginosa . Biofilms were formed over two days, after which e-bandages were placed on the wound beds and covered with Tegaderm™. Mice were administered Tegaderm-only (control), non-polarized e-bandage (no HOCl production), or polarized e-bandage (using an HOCl-producing potentiostat), with or without concurrently administered systemic amikacin. Purulence and wound areas were measured before and after treatment. After 48 hours, animals were sacrificed, and wounds were harvested for bacterial quantification. Forty-eight hours of polarized e-bandage treatment resulted in mean biofilm reductions of 1.4 log 10 CFUs/g (9.0 vs 7.6 log 10 ; p = 0.0107) vs non-polarized controls, and 2.2 log 10 CFU/g (9.8 vs 7.6 log 10 ; p = 0.004) vs Tegaderm only controls. Systemic amikacin improved CFU reduction in Tegaderm-only (p = 0.0045) and non-polarized control groups (p = 0.0312), but not in the polarized group (p = 0.3876). Compared to the Tegaderm only group, there was more purulence reduction in the polarized group (p = 0.009), but not in the non-polarized group (p = 0.064). Wound closure was not impeded or improved by either polarized or non-polarized e-bandage treatment. Concurrent amikacin did not impact wound closure or purulence. In conclusion, an HOCl-producing e-bandage reduced P. aeruginosa in wound biofilms with no impairment in wound healing, representing a promising antibiotic-free approach for addressing wound infections.
Collapse
|
5
|
Tibbits G, Mohamed A, Gelston S, Flurin L, Raval YS, Greenwood-Quaintance KE, Patel R, Beyenal H. Activity of a hypochlorous acid-producing electrochemical bandage as assessed with a porcine explant biofilm model. Biotechnol Bioeng 2023; 120:250-259. [PMID: 36168277 PMCID: PMC10091757 DOI: 10.1002/bit.28248] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/18/2022] [Accepted: 09/25/2022] [Indexed: 11/10/2022]
Abstract
The activity of a hypochlorous acid-producing electrochemical bandage (e-bandage) in preventing methicillin-resistant Staphylococcus aureus infection (MRSA) infection and removing biofilms formed by MRSA was assessed using a porcine explant biofilm model. e-Bandages inhibited S. aureus infection (p = 0.029) after 12 h (h) of exposure and reduced 3-day biofilm viable cell counts after 6, 12, and 24 h exposures (p = 0.029). Needle-type microelectrodes were used to assess HOCl concentrations in explant tissue as a result of e-bandage treatment; toxicity associated with e-bandage treatment was evaluated. HOCl concentrations in infected and uninfected explant tissue varied between 30 and 80 µM, decreasing with increasing distance from the e-bandage. Eukaryotic cell viability was reduced by an average of 71% and 65% in fresh and day 3-old explants, respectively, when compared to explants exposed to nonpolarized e-bandages. HOCl e-bandages are a promising technology that can be further developed as an antibiotic-free treatment for wound biofilm infections.
Collapse
Affiliation(s)
- Gretchen Tibbits
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | - Abdelrhman Mohamed
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | - Suzanne Gelston
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| | - Laure Flurin
- Divison of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Yash S Raval
- Divison of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Robin Patel
- Divison of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota, USA.,Division of Public Health, Infectious Diseases and Occupational Medicine, Mayo Clinic, Rochester, Minnesota, USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
| |
Collapse
|