1
|
Hojo E, Glaser KJ, Harada-Hayashi A, Le Y, Chen J, Hulshizer TC, Rossman PJ, Noyori S, Roberts N. Feasibility study of the application of magnetic resonance elastography (MRE) to measure oral posture related changes in stiffness of zygomaticus major muscle. Magn Reson Imaging 2024; 111:196-201. [PMID: 38723783 DOI: 10.1016/j.mri.2024.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/20/2024] [Accepted: 05/06/2024] [Indexed: 05/24/2024]
Abstract
PURPOSE Development of a technique for measuring the mechanical properties of zygomaticus major (ZM) may aid advances in clinical treatments for correcting abnormal oral posture. The objective of this work was to demonstrate the feasibility of measuring the stiffness of ZM using an MR elastography technique that incorporates a custom local driver and a phase-gradient (PG) inversion. METHODS 2D MRE investigations were performed for 3 healthy subjects using a vibration frequency of 90 Hz to test the prediction that the stiffness of ZM would be greater in the mouth-open compared to the mouth-closed position. MRE wave images were acquired along the long axis of ZM and processed using a 2D spatial-temporal directional filter applied in the direction of wave propagation along the long axis of the muscle. Stiffness measurements were obtained by applying the PG technique to a 1D-profile drawn in the phase image of the first harmonic of the wave images and a one-tailed paired t-test was used to compare the ZM stiffness between the two mouth postures (p < 0.05). RESULTS The mean stiffness and standard deviation (SD) of ZM across the three participants in the mouth-closed and mouth-open postures was 6.75 kPa (SD 3.36 kPa) and 15.5 kPa (SD 5.15 kPa), respectively. Changes of ZM stiffness were significantly greater in the mouth-open than the mouth-closed posture (p = 0.038). CONCLUSION The feasibility of using the PG MRE technique to measure stiffness changes in a small muscle such as ZM for different mouth postures has been demonstrated. Further investigations are required in a larger cohort of participants to investigate the sensitivity and reproducibility of the technique for potential clinical application as well as in health and beauty related studies.
Collapse
Affiliation(s)
- Emi Hojo
- Centre for Reproductive Health (CRH), Institute for Regeneration and Repair (IRR), 4-5 Little France Drive, Edinburgh EH16 4UU, UK; Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA
| | - Kevin J Glaser
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA
| | - Ayako Harada-Hayashi
- Rohto Pharmaceutical Company, 1-8-1, Tatsumi-nishi, Ikunoku, Osaka 544-8666, Japan
| | - Yuan Le
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA
| | - Jun Chen
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA; Department of Radiology, Nanjing Drum Tower Hospital, 321 Zhongshan Rd, Gulou, Nanjing, Jiangsu 210008, China; Resoundant, Inc., 421 1st Ave SW, Rochester, MN, USA
| | - Thomas C Hulshizer
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA
| | - Phillip J Rossman
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA
| | - Sachiko Noyori
- Rohto Pharmaceutical Company, 1-8-1, Tatsumi-nishi, Ikunoku, Osaka 544-8666, Japan
| | - Neil Roberts
- Centre for Reproductive Health (CRH), Institute for Regeneration and Repair (IRR), 4-5 Little France Drive, Edinburgh EH16 4UU, UK.
| |
Collapse
|
2
|
Yang Y, Shahryari M, Meyer T, Marticorena Garcia SR, Görner S, Salimi Majd M, Guo J, Braun J, Sack I, Tzschätzsch H. Explorative study using ultrasound time-harmonic elastography for stiffness-based quantification of skeletal muscle function. Z Med Phys 2024:S0939-3889(24)00027-8. [PMID: 38508947 DOI: 10.1016/j.zemedi.2024.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/29/2024] [Accepted: 03/01/2024] [Indexed: 03/22/2024]
Abstract
Time-harmonic elastography (THE) is an emerging ultrasound imaging technique that allows full-field mapping of the stiffness of deep biological tissues. THE's unique ability to rapidly capture stiffness in multiple tissues has never been applied for imaging skeletal muscle. Therefore, we addressed the lack of data on temporal changes in skeletal muscle stiffness while simultaneously covering stiffness of different muscles. Acquiring repeated THE scans every five seconds we quantified shear-wave speed (SWS) as a marker of stiffness of the long head (LHB) and short head (SHB) of biceps brachii and of the brachialis muscle (B) in ten healthy volunteers. SWS was continuously acquired during a 3-min isometric preloading phase, a 3-min loading phase with different weights (4, 8, and 12 kg), and a 9-min postloading phase. In addition, we analyzed temporal SWS standard deviation (SD) as a marker of muscle contraction regulation. Our results (median [min, max]) showed both SWS at preloading (LHB: 1.04 [0.94, 1.12] m/s, SHB: 0.86 [0.78, 0.94] m/s, B: 0.96 [0.87, 1.09] m/s, p < 0.001) and the increase in SWS with loading weight to be muscle-specific (LHB: 0.010 [0.002, 0.019] m/s/kg, SHB: 0.022 [0.017, 0.042] m/s/kg, B: 0.039 [0.019, 0.062] m/s/kg, p < 0.001). Additionally, SWS during loading increased continuously over time by 0.022 [0.004, 0.051] m/s/min (p < 0.01). Using an exponential decay model, we found an average relaxation time of 27 seconds during postloading. Analogously, SWS SD at preloading was also muscle-specific (LHB: 0.018 [0.011, 0.029] m/s, SHB: 0.021 [0.015, 0.027] m/s, B: 0.024 [0.018, 0.037] m/s, p < 0.05) and increased by 0.005 [0.003, 0.008] m/s/kg (p < 0.01) with loading. SWS SD did not change over loading time and decreased immediately in the postloading phase. Taken together, THE of skeletal muscle is a promising imaging technique for in vivo quantification of stiffness and stiffness changes in multiple muscle groups within seconds. Both the magnitude of stiffness changes and their temporal variation during isometric exercise may reflect the functional status of skeletal muscle and provide additional information to the morphological measures obtained by conventional imaging modalities.
Collapse
Affiliation(s)
- Yang Yang
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Mehrgan Shahryari
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Tom Meyer
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Stephan Rodrigo Marticorena Garcia
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Steffen Görner
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Mahsa Salimi Majd
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Jing Guo
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Heiko Tzschätzsch
- Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany.
| |
Collapse
|
3
|
Melo AS, Montóia B, Cruz EB, Vilas-Boas JP, Sousa AS. Scapular muscle dynamic stiffness of asymptomatic subjects and subjects with chronic shoulder pain, at rest and isometric contraction conditions. Proc Inst Mech Eng H 2024; 238:288-300. [PMID: 38403635 DOI: 10.1177/09544119241228082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
Muscle stiffness had a crucial role in joint stability, particularly, at the shoulder complex. Although changes in upper trapezius muscle stiffness have been described for shoulder pain, contradictory findings have been obtained. Also, existing data regarding scapular muscles are, majorly, about trapezius. Myotonometry is a method used to assess stiffness; however, the reliability values of scapular muscle stiffness through this method have not been assessed in shoulder pain conditions. The present study aims to compare scapular muscles' stiffness (trapezius, serratus anterior, and levator scapulae) between subjects with and without chronic shoulder pain and to evaluate the related test-retest reliability. Twenty-two symptomatic and twenty-two asymptomatic subjects participated in a cross-sectional study. The dynamic muscular stiffness of scapular muscles, at rest and during an isometric contraction, was measured bilaterally with myotonometry, in two moments. The differences in bilateral averaged values between symptomatic and asymptomatic subjects and the effect of the group (group presenting pain in the dominant or non-dominant side, and asymptomatic group) and of the limb (unilateral painful or asymptomatic limb, and bilateral asymptomatic limbs) were investigated. Test-retest intra-rater reliability was determined. An effect of the group was observed at rest, for middle trapezius stiffness, and during contraction, for middle and lower trapezius stiffness. For middle trapezius, increased values were observed in the group presenting pain in non-dominant side comparing to both groups or to group presenting pain in dominant side. The intraclass correlation coefficient, majorly, ranged between 0.775 and 0.989. Participants with pain in the non-dominant side presented an increased middle trapezius' stiffness. Globally, high reliability was observed for scapular muscles dynamic stiffness.
Collapse
Affiliation(s)
- Ana Sc Melo
- Centro de Investigação em Reabilitação (CIR), Escola Superior de Saúde, Instituto Politécnico do Porto, Porto, Portugal
- Centro de Investigação em Actividade Física, Saúde e Lazer (CIAFEL), Faculdade de Desporto, Universidade do Porto, Porto, Portugal
- Laboratório de Biomecânica do Porto (LABIOMEP), Universidade do Porto, Porto, Portugal
- Centro Interdisciplinar de Investigação Aplicada em Saúde (CIIAS), Escola Superior de Saúde, Instituto Politécnico de Setúbal, Setúbal, Portugal
| | - Bárbara Montóia
- Escola Superior de Saúde, Politécnico do Porto, Porto, Portugal
| | - Eduardo B Cruz
- Departamento de Fisioterapia, Escola Superior de Saúde, Instituto Politécnico de Setúbal, Setúbal, Portugal
- Centro de Investigação Integrada em Saúde (CHRC), Universidade Nova de Lisboa, Lisboa, Portugal
| | - J Paulo Vilas-Boas
- Laboratório de Biomecânica do Porto (LABIOMEP), Universidade do Porto, Porto, Portugal
- Centro de Investigação, Formação, Inovação e Intervenção em Desporto (CIFI2D), Faculdade de Desporto, Universidade do Porto, Porto, Portugal
| | - Andreia Sp Sousa
- Centro de Investigação em Reabilitação (CIR), Escola Superior de Saúde, Instituto Politécnico do Porto, Porto, Portugal
| |
Collapse
|
4
|
Feng Y, Murphy MC, Hojo E, Li F, Roberts N. Magnetic Resonance Elastography in the Study of Neurodegenerative Diseases. J Magn Reson Imaging 2024; 59:82-96. [PMID: 37084171 DOI: 10.1002/jmri.28747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/03/2023] [Accepted: 04/04/2023] [Indexed: 04/22/2023] Open
Abstract
Neurodegenerative diseases such as Alzheimer's disease (AD) and Parkinson's disease (PD) present a major health burden to society. Changes in brain structure and cognition are generally only observed at the late stage of the disease. Although advanced magnetic resonance imaging (MRI) techniques such as diffusion imaging may allow identification of biomarkers at earlier stages of neurodegeneration, early diagnosis is still challenging. Magnetic resonance elastography (MRE) is a noninvasive MRI technique for studying the mechanical properties of tissues by measuring the wave propagation induced in the tissues using a purpose-built actuator. Here, we present a systematic review of preclinical and clinical studies in which MRE has been applied to study neurodegenerative diseases. Actuator systems for data acquisition, inversion algorithms for data analysis, and sample demographics are described and tissue stiffness measures obtained for the whole brain and internal structures are summarized. A total of six animal studies and eight human studies have been published. The animal studies refer to 123 experimental animals (68 AD and 55 PD) and 121 wild-type animals, while the human studies refer to 142 patients with neurodegenerative disease (including 56 AD and 17 PD) and 166 controls. The animal studies are consistent in the reporting of decreased stiffness of the hippocampal region in AD mice. However, in terms of disease progression, although consistent decreases in either storage modulus or shear modulus magnitude are reported for whole brain, there is variation in the results reported for the hippocampal region. The clinical studies are consistent in reports of a significant decrease in either whole brain storage modulus or shear modulus magnitude, in both AD and PD and with different brain structures affected in different neurodegenerative diseases. MRE studies of neurodegenerative diseases are still in their infancy, and in future it will be interesting to investigate potential relationships between brain mechanical properties and clinical measures, which may help elucidate the mechanisms underlying onset and progression of neurodegenerative diseases. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Yuan Feng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, China
| | - Matthew C Murphy
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, USA
| | - Emi Hojo
- Centre for Reproductive Health (CRH), School of Clinical Sciences, University of Edinburgh, Edinburgh, UK
| | - Fei Li
- Department of Radiology and Huaxi MR Research Center (HMRRC), Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Neil Roberts
- Centre for Reproductive Health (CRH), School of Clinical Sciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
5
|
Suwankanit K, Shimizu M, Suzuki K, Kaneda M. Usefulness of Ultrasound Shear Wave Elastography for Detection of Quadriceps Contracture in Immobilized Rats. Animals (Basel) 2023; 14:76. [PMID: 38200807 PMCID: PMC10778017 DOI: 10.3390/ani14010076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
Quadriceps contracture is an abnormal pathological shortening of the muscle-tendon unit. To improve the prognosis of quadriceps contracture, improvement of its diagnostic method is needed. In this study, we evaluated the diagnostic utility of ultrasound shear wave elastography in a rat model of quadriceps contracture induced by immobilization. Fifty Wistar rats were randomly divided into control and immobilization groups. During up to 4 weeks of joint immobilization, the quadriceps elastic modulus, muscle hardness, creatinine phosphokinase levels, joint range of motion, histopathologic parameters, and levels of fibrosis-associated mRNA expression were measured every week in the immobilization and control groups and compared. In the immobilization group, the elastic modulus gradually but significantly increased (p < 0.05) throughout the immobilization period. However, muscle hardness and serum creatinine phosphokinase levels only increased at 1 and 2 weeks after the start of immobilization, respectively. Muscle atrophy and shortening progressed throughout the immobilization group. Collagen type I and III, α-SMA protein, and mRNA expression of IL-1β and TGF-β1 significantly increased (p < 0.05) throughout in the immobilization group. Ultrasound shear wave elastography is the most useful method for clinical assessment of muscle contracture.
Collapse
Affiliation(s)
- Kanokwan Suwankanit
- Department of Veterinary Diagnostic Imaging, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Tokyo 183-0054, Japan;
- Department of Clinical Sciences and Public Health, Faculty of Veterinary Science, Mahidol University, Nakhon Pathom 73170, Thailand
| | - Miki Shimizu
- Department of Veterinary Diagnostic Imaging, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Tokyo 183-0054, Japan;
| | - Kazuhiko Suzuki
- Laboratory of Veterinary Toxicology, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Tokyo 183-0054, Japan;
| | - Masahiro Kaneda
- Laboratory of Veterinary Anatomy, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Tokyo 183-8509, Japan;
| |
Collapse
|
6
|
Chevalier B, Bedretdinova D, Pellot-Barakat C, Maître X, Creze M. Evaluation of the Reproducibility of MR Elastography Measurements of the Lumbar Back Muscles. J Magn Reson Imaging 2023. [PMID: 38100302 DOI: 10.1002/jmri.29178] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND MR elastography (MRE) may provide quantitative imaging biomarkers of lumbar back muscles (LBMs), complementing MRI in spinal diseases by assessing muscle mechanical properties. However, reproducibility analyses for MRE of LBM are lacking. PURPOSE To assess technical failure, within-day and inter-day reproducibility, robustness with the excitation source positioning, and inter-observer agreement of MRE of muscles. STUDY TYPE Prospective. SUBJECTS Seventeen healthy subjects (mean age 28 ± 4 years; 11 females). FIELD STRENGTH/SEQUENCE 1.5 T, gradient-echo MRE, T1-weighted turbo spin echo. ASSESSMENT The pneumatic driver was centered at L3 level. Four MRE were performed during two visits, 2-4 weeks apart, each consisting of two MRE with less than 10 minutes inter-scan interval. At Visit 1, after the first MRE, the coil and driver were removed, then reinstalled. The MRE was repeated. At Visit 2, following the first MRE, only the driver was moved down 5 cm. The MRE was repeated. Two radiologists segmented the multifidus and erector spinae muscles. STATISTICAL TESTS Paired t-test, analysis of variance, intraclass correlation coefficients (ICCs). P-values <0.05 were considered statistically significant. RESULTS Mean stiffness of LBM ranged from 1.44 to 1.60 kPa. Mean technical failure rate was 2.5%. Inter-observer agreement was excellent (ICC ranging from 0.82 [0.64-0.96] to 0.99 [0.98-0.99] in the multifidus, and from 0.85 [0.69-0.92] to 0.99 [0.97-0.99] in the erector spinae muscles). Within-day reproducibility was fair in the multifidus (ICC: 0.53 [0.47-0.77]) and good in the erector spinae muscles (ICC: 0.74 [0.48-0.88]). Reproducibility after moving the driver was excellent in both multifidus (ICC: 0.85 [0.69-0.93]) and erector spinae muscles (ICC: 0.84 [0.67-0.92]). Inter-day reproducibility was excellent in the multifidus (ICC: 0.76 [0.48-0.89]) and poor in the erector spinae muscles (ICC: 0.23 [-0.61 to 0.63]). DATA CONCLUSION MRE of LBM provides measurements of stiffness with fair to excellent reproducibility and excellent inter-observer agreement. However, inter-day reproducibility in the multifidus muscles indicated that the herein used MRE protocol may not be optimal for this muscle. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Benjamin Chevalier
- Department of Radiology, Cochin Hospital, Université Paris Cité, APHP, Paris, France
| | - Dina Bedretdinova
- Center for Research in Epidemiology and StatisticS (CRESS), Université Paris Cité and Université Sorbonne Paris Nord, Inserm, INRAE, Paris, France
| | - Claire Pellot-Barakat
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
| | - Xavier Maître
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
| | - Maud Creze
- Laboratoire d'Imagerie Biomédicale Multimodale, BIOMAPS, Université Paris-Saclay, Service Hospitalier Frederic Joliot, Orsay, France
- Department of Radiology, Bicêtre Hospital, Université Paris-Saclay, APHP, Le Kremlin Bicêtre, France
- Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, Paris, France
| |
Collapse
|
7
|
de Visser M, Carlier P, Vencovský J, Kubínová K, Preusse C. 255th ENMC workshop: Muscle imaging in idiopathic inflammatory myopathies. 15th January, 16th January and 22nd January 2021 - virtual meeting and hybrid meeting on 9th and 19th September 2022 in Hoofddorp, The Netherlands. Neuromuscul Disord 2023; 33:800-816. [PMID: 37770338 DOI: 10.1016/j.nmd.2023.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 08/20/2023] [Accepted: 08/25/2023] [Indexed: 09/30/2023]
Abstract
The 255th ENMC workshop on Muscle Imaging in Idiopathic Inflammatory myopathies (IIM) aimed at defining recommendations concerning the applicability of muscle imaging in IIM. The workshop comprised of clinicians, researchers and people living with myositis. We aimed to achieve consensus on the following topics: a standardized protocol for the evaluation of muscle images in various types of IIMs; the exact parameters, anatomical localizations and magnetic resonance imaging (MRI) techniques; ultrasound as assessment tool in IIM; assessment methods; the pattern of muscle involvement in IIM subtypes; the application of MRI as biomarker in follow-up studies and clinical trials, and the place of MRI in the evaluation of swallowing difficulty and cardiac manifestations. The following recommendations were formulated: In patients with suspected IIM, muscle imaging is highly recommended to be part of the initial diagnostic workup and baseline assessment. MRI is the preferred imaging modality due to its sensitivity to both oedema and fat accumulation. Ultrasound may be used for suspected IBM. Repeat imaging should be considered if patients do not respond to treatment, if there is ongoing diagnostic uncertainty or there is clinical or laboratory evidence of disease relapse. Quantitative MRI is established as a sensitive biomarker in IBM and could be included as a primary or secondary outcome measure in early phase clinical trials, or as a secondary outcome measure in late phase clinical trials. Finally, a research agenda was drawn up.
Collapse
Affiliation(s)
- Marianne de Visser
- Department of Neurology, Amsterdam Neuroscience, Amsterdam University Medical Centre, Location Academic Medical Centre, University of Amsterdam, Amsterdam, The Netherlands.
| | | | - Jiří Vencovský
- Institute of Rheumatology, Department of Rheumatology, Charles University, Prague, Czech Republic
| | - Kateřina Kubínová
- Institute of Rheumatology, Department of Rheumatology, Charles University, Prague, Czech Republic
| | - Corinna Preusse
- Charité-Universitätsmedizin Berlin, Corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin Institute of Health Department of Neuropathology, Berlin, Germany
| |
Collapse
|
8
|
Blemker SS. In vivo imaging of skeletal muscle form and function: 50 years of insight. J Biomech 2023; 158:111745. [PMID: 37579605 DOI: 10.1016/j.jbiomech.2023.111745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 07/22/2023] [Accepted: 07/27/2023] [Indexed: 08/16/2023]
Abstract
Skeletal muscle form and function has fascinated scientists for centuries. Our understanding of muscle function has long been driven by advancements in imaging techniques. For example, the sliding filament theory of muscle, which is now widely leveraged in biomechanics research, stemmed from observations made possible by scanning electron microscopy. Over the last 50 years, advancing in medical imaging, combined with ingenuity and creativity of biomechanists, have provide a wealth of new and important insights into in vivo human muscle function. Incorporation of in vivo imaging has also advanced computational modeling and allowed our research to have an impact in many clinical populations. While this review does not provide a comprehensive or meta-analysis of the all the in vivo muscle imaging work over the last five decades, it provides a narrative about the past, present, and future of in vivo muscle imaging.
Collapse
Affiliation(s)
- Silvia S Blemker
- Departments of Biomedical Engineering, Mechanical & Aerospace Engineering, Ophthalmology, and Orthopedic Surgery, University of Virginia, Charlottesville, VA, United States; Springbok Analytics, Charlottesville, VA, United States
| |
Collapse
|
9
|
Dick TJM, Hug F. Advances in imaging for assessing the design and mechanics of skeletal muscle in vivo. J Biomech 2023; 155:111640. [PMID: 37244210 DOI: 10.1016/j.jbiomech.2023.111640] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 05/10/2023] [Indexed: 05/29/2023]
Abstract
Skeletal muscle is the engine that powers what is arguably the most essential and defining feature of human and animal life-locomotion. Muscles function to change length and produce force to enable movement, posture, and balance. Despite this seemingly simple role, skeletal muscle displays a variety of phenomena that still remain poorly understood. These phenomena are complex-the result of interactions between active and passive machinery, as well as mechanical, chemical and electrical processes. The emergence of imaging technologies over the past several decades has led to considerable discoveries regarding how skeletal muscles function in vivo where activation levels are submaximal, and the length and velocity of contracting muscle fibres are transient. However, our knowledge of the mechanisms of muscle behaviour during everyday human movements remains far from complete. In this review, we discuss the principal advancements in imaging technology that have led to discoveries to improve our understanding of in vivo muscle function over the past 50 years. We highlight the knowledge that has emerged from the development and application of various techniques, including ultrasound imaging, magnetic resonance imaging, and elastography to characterise muscle design and mechanical properties. We emphasize that our inability to measure the forces produced by skeletal muscles still poses a significant challenge, and that future developments to accurately and reliably measure individual muscle forces will promote newfrontiers in biomechanics, physiology, motor control, and robotics. Finally, we identify critical gaps in our knowledge and future challenges that we hope can be solved as a biomechanics community in the next 50 years.
Collapse
Affiliation(s)
- Taylor J M Dick
- The University of Queensland, School of Biomedical Sciences, Brisbane, QLD, Australia.
| | - François Hug
- The University of Queensland, School of Biomedical Sciences, Brisbane, QLD, Australia; Université Côte d'Azur, LAMHESS, Nice, France
| |
Collapse
|
10
|
Smith DR, Caban-Rivera DA, Williams LT, Van Houten EE, Bayly PV, Paulsen KD, McGarry MD, Johnson CL. In vivoestimation of anisotropic mechanical properties of the gastrocnemius during functional loading with MR elastography. Phys Med Biol 2023; 68:10.1088/1361-6560/acb482. [PMID: 36652716 PMCID: PMC9943592 DOI: 10.1088/1361-6560/acb482] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 01/18/2023] [Indexed: 01/20/2023]
Abstract
Objective.In vivoimaging assessments of skeletal muscle structure and function allow for longitudinal quantification of tissue health. Magnetic resonance elastography (MRE) non-invasively quantifies tissue mechanical properties, allowing for evaluation of skeletal muscle biomechanics in response to loading, creating a better understanding of muscle functional health.Approach. In this study, we analyze the anisotropic mechanical response of calf muscles using MRE with a transversely isotropic, nonlinear inversion algorithm (TI-NLI) to investigate the role of muscle fiber stiffening under load. We estimate anisotropic material parameters including fiber shear stiffness (μ1), substrate shear stiffness (μ2), shear anisotropy (ϕ), and tensile anisotropy (ζ) of the gastrocnemius muscle in response to both passive and active tension.Main results. In passive tension, we found a significant increase inμ1,ϕ,andζwith increasing muscle length. While in active tension, we observed increasingμ2and decreasingϕandζduring active dorsiflexion and plantarflexion-indicating less anisotropy-with greater effects when the muscles act as agonist.Significance. The study demonstrates the ability of this anisotropic MRE method to capture the multifaceted mechanical response of skeletal muscle to tissue loading from muscle lengthening and contraction.
Collapse
Affiliation(s)
- Daniel R. Smith
- Department of Biomedical Engineering, University of Delaware, Newark DE, 19711
- Department of Orthopaedics, Emory University School of Medicine, Atlanta GA, 30307
- Emory Sports Performance and Research Center, Flowery Branch GA, 30542
| | | | - L. Tyler Williams
- Department of Biomedical Engineering, University of Delaware, Newark DE, 19711
| | | | - Phil V. Bayly
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis MO
| | - Keith D. Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover NH, 03755
- Dartmouth-Hitchcock Medical Center, Lebanon NH, 03756
| | | | - Curtis L. Johnson
- Department of Biomedical Engineering, University of Delaware, Newark DE, 19711
| |
Collapse
|
11
|
Melo ASC, Cruz EB, Vilas-Boas JP, Sousa ASP. Scapular Dynamic Muscular Stiffness Assessed through Myotonometry: A Narrative Review. SENSORS 2022; 22:s22072565. [PMID: 35408180 PMCID: PMC9002787 DOI: 10.3390/s22072565] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 03/21/2022] [Accepted: 03/23/2022] [Indexed: 02/04/2023]
Abstract
Several tools have been used to assess muscular stiffness. Myotonometry stands out as an accessible, handheld, and easy to use tool. The purpose of this review was to summarize the psychometric properties and methodological considerations of myotonometry and its applicability in assessing scapular muscles. Myotonometry seems to be a reliable method to assess several muscles stiffness, as trapezius. This method has been demonstrated fair to moderate correlation with passive stiffness measured by shear wave elastography for several muscles, as well as with level of muscle contraction, pinch and muscle strength, Action Research Arm Test score and muscle or subcutaneous thickness. Myotonometry can detect scapular muscles stiffness differences between pre- and post-intervention in painful conditions and, sometimes, between symptomatic and asymptomatic subjects.
Collapse
Affiliation(s)
- Ana S. C. Melo
- Center for Rehabilitation Research—Human Movement System (Re)habilitation Area, Department of Physiotherapy, School of Health, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida, 400, 4200-072 Porto, Portugal;
- Research Centre in Physical Activity, Health and Leisure, Faculty of Sport, University of Porto, Rua Dr. Plácido Costa, 91, 4200-450 Porto, Portugal
- Porto Biomechanics Laboratory (LABIOMEP-UP), University of Porto, Rua Dr. Plácido Costa, 91, 4200-450 Porto, Portugal;
- Center for Interdisciplinary Applied Research in Health, School of Health, Setubal Polytechnic Institute, Campus do IPS Estefanilha, 2914-503 Setubal, Portugal
| | - Eduardo B. Cruz
- Department of Physiotherapy, School of Health, Setubal Polytechnic Institute, Campus do IPS Estefanilha, 2914-503 Setubal, Portugal;
- Comprehensive Health Research Center (CHRC), Universidade Nova de Lisboa, 1169-056 Lisboa, Portugal
| | - João Paulo Vilas-Boas
- Porto Biomechanics Laboratory (LABIOMEP-UP), University of Porto, Rua Dr. Plácido Costa, 91, 4200-450 Porto, Portugal;
- Centre of Research, Education, Innovation and Intervention in Sport (CIFI2D), Faculty of Sport, University of Porto, Rua Dr. Plácido Costa, 91, 4200-450 Porto, Portugal
| | - Andreia S. P. Sousa
- Center for Rehabilitation Research—Human Movement System (Re)habilitation Area, Department of Physiotherapy, School of Health, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida, 400, 4200-072 Porto, Portugal;
- Correspondence: or
| |
Collapse
|
12
|
Cao J, Xiao Y, Qiu W, Zhang Y, Dou Z, Ren J, Zheng R, Zheng H, Chen Z. Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients. J Neuroeng Rehabil 2022; 19:15. [PMID: 35120556 PMCID: PMC8817514 DOI: 10.1186/s12984-022-00995-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 01/25/2022] [Indexed: 12/21/2022] Open
Abstract
Background To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. Methods Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis. Results The intra- (0.791 95% CI 0.432–0.932) and interobserver (0.751 95% CI 0.382–0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = − 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%. Conclusion 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity. Supplementary Information The online version contains supplementary material available at 10.1186/s12984-022-00995-8.
Collapse
Affiliation(s)
- Junyan Cao
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Yang Xiao
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen, 518055, China
| | - Weihong Qiu
- Department of Rehabilitation Medicine, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Yanling Zhang
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Zulin Dou
- Department of Rehabilitation Medicine, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Jie Ren
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Rongqin Zheng
- Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen, 518055, China
| | - Zhaocong Chen
- Department of Rehabilitation Medicine, The Third Affiliated Hospital of Sun Yat-Sen University, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China.
| |
Collapse
|
13
|
Aphinives C, Kiatsayompoo W, Eurboonyanun K, Twinprai P, Jaruchainiwat S. Tissue stiffness in BPH patients from magnetic resonance elastography. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [PMCID: PMC8667017 DOI: 10.1186/s43055-021-00679-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Background BPH is commonly found in older men which can lead to lower urinary tract symptoms. Magnetic resonance elastography (MRE) is an innovative, noninvasive imaging technique used to evaluate tissue stiffness. There has not been any study, however, that assessed the tissue stiffness in patients with BPH. A prospective descriptive study was performed to demonstrated MRI and MRE techniques of the prostate gland in ten patients with BPH to assess tissue stiffness, features of BPH on MRI and components of BPH in the area of increased stiffness. Results MRI and MRE examinations in all patients were successful without any complications. The mean tissue stiffness of the whole prostate gland was 4.40 ± 0.71 kPa with good reproducibility (ICC 0.82). Stromal components and mixed glandular-stromal components tended to be associated with the areas of increased stiffness on stiffness images, 50.6% for stromal components and 37.9% for mixed glandular-stromal components. Some MRI findings were seen on the patients with high mean stiffness values such as prostatic calcification, type-5 BPH pattern and large prostate volumes. Conclusions Prostate MRE is a useful noninvasive reproducible diagnostic tool for evaluating prostate tissue stiffness by both qualitative and quantitative assessments. The mean prostate tissue stiffness from MRE in patients with BPH in this study was 4.40 ± 0.71 kPa. Some MRI features might be associated with increased tissue stiffness. Trial registration: PID 229. Registered 4 October 2019. http://md.redcap.kku.ac.th
Collapse
|
14
|
Tavakoli J, Geargeflia S, Tipper JL, Diwan AD. Magnetic resonance elastography: A non-invasive biomarker for low back pain studies. BIOMEDICAL ENGINEERING ADVANCES 2021. [DOI: 10.1016/j.bea.2021.100014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
15
|
Gili T, Di Carlo G, Capuani S, Auconi P, Caldarelli G, Polimeni A. Complexity and data mining in dental research: A network medicine perspective on interceptive orthodontics. Orthod Craniofac Res 2021; 24 Suppl 2:16-25. [PMID: 34519158 PMCID: PMC9292769 DOI: 10.1111/ocr.12520] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 06/23/2021] [Indexed: 12/19/2022]
Abstract
Procedures and models of computerized data analysis are becoming researchers' and practitioners' thinking partners by transforming the reasoning underlying biomedicine. Complexity theory, Network analysis and Artificial Intelligence are already approaching this discipline, intending to provide support for patient's diagnosis, prognosis and treatments. At the same time, due to the sparsity, noisiness and time-dependency of medical data, such procedures are raising many unprecedented problems related to the mismatch between the human mind's reasoning and the outputs of computational models. Thanks to these computational, non-anthropocentric models, a patient's clinical situation can be elucidated in the orthodontic discipline, and the growth outcome can be approximated. However, to have confidence in these procedures, orthodontists should be warned of the related benefits and risks. Here we want to present how these innovative approaches can derive better patients' characterization, also offering a different point of view about patient's classification, prognosis and treatment.
Collapse
Affiliation(s)
- Tommaso Gili
- Networks UnitIMT School for Advanced Studies LuccaLuccaItaly
- CNR‐ISC Unità SapienzaRomeItaly
| | - Gabriele Di Carlo
- Department of Oral and Maxillo‐Facial SciencesSapienza University of RomeRomeItaly
| | | | | | - Guido Caldarelli
- CNR‐ISC Unità SapienzaRomeItaly
- Department of Molecular Sciences and NanosystemsCa’Foscari University of VeniceVenezia MestreItaly
| | - Antonella Polimeni
- Department of Oral and Maxillo‐Facial SciencesSapienza University of RomeRomeItaly
| |
Collapse
|
16
|
Guidetti M, Zampini MA, Jiang Y, Gambacorta C, Smejkal JP, Crutison J, Pan Y, Klatt D, Royston TJ. Axially- and torsionally-polarized radially converging shear wave MRE in an anisotropic phantom made via Embedded Direct Ink Writing. J Mech Behav Biomed Mater 2021; 119:104483. [PMID: 33838445 PMCID: PMC8137604 DOI: 10.1016/j.jmbbm.2021.104483] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/09/2021] [Accepted: 03/15/2021] [Indexed: 11/28/2022]
Abstract
Magnetic Resonance Elastography (MRE) is a non-invasive imaging method to quantitatively map the shear viscoelastic properties of soft tissues. In this study, Embedded Direct Ink Writing is used to fabricate a muscle mimicking anisotropic phantom that may serve as a standard for imaging studies of anisotropic materials. The technique allowed us to obtain a long shelf life silicone-based phantom expressing transverse isotropic mechanical properties. Another goal of the present investigation is to introduce a torsionally-polarized, radially-converging shear wave actuation method for MRE. The implemented design for this novel setup was first validated via its application to isotropic and homogeneous gelatin phantoms. Then, a comparison of the resulting complex wave images from axially- and torsionally-polarized MRE on the developed anisotropic phantom and on a skeletal muscle murine sample is presented, highlighting the value of using multiple actuation and motion encoding polarization directions when studying anisotropic materials.
Collapse
Affiliation(s)
- Martina Guidetti
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
| | | | - Yizhou Jiang
- University of Illinois at Chicago, Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Chiara Gambacorta
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Joshua P Smejkal
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Joseph Crutison
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Yayue Pan
- University of Illinois at Chicago, Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Dieter Klatt
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Thomas J Royston
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
17
|
Gimber LH, Daniel Latt L, Caruso C, Nuncio Zuniga AA, Krupinski EA, Klauser AS, Taljanovic MS. Ultrasound shear wave elastography of the anterior talofibular and calcaneofibular ligaments in healthy subjects. J Ultrason 2021; 21:e86-e94. [PMID: 34258033 PMCID: PMC8264467 DOI: 10.15557/jou.2021.0017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 04/26/2021] [Indexed: 12/26/2022] Open
Abstract
Aim of study Most sprained lateral ankle ligaments heal uneventfully, but in some cases the ligament’s elastic function is not restored, leading to chronic ankle instability. Ultrasound shear wave elastography can be used to quantify the elasticity of musculoskeletal soft tissues; it may serve as a test of ankle ligament function during healing to potentially help differentiate normal from ineffective healing. The purpose of this study was to determine baseline shear wave velocity values for the lateral ankle ligaments in healthy male subjects, and to assess inter-observer reliability. Material and methods Forty-six ankles in 23 healthy male subjects aged 20–40 years underwent shear wave elastography of the lateral ankle ligaments performed by two musculoskeletal radiologists. Each ligament was evaluated three times with the ankle relaxed by both examiners, and under stress by a single examiner. Mean shear wave velocity values were compared for each ligament by each examiner. Inter-observer agreement was evaluated. Results The mean shear wave velocity at rest for the anterior talofibular ligament was 2.09 ± 0.3 (range 1.41–3.17); and for the calcaneofibular ligament 1.99 ± 0.36 (range 1.29–2.88). Good inter-observer agreement was found for the anterior talofibular ligament and calcaneofibular ligament shear wave velocity measurements with the ankle in resting position. There was a significant difference in mean shear wave velocities between rest and stressed conditions for both anterior talofibular ligament (2.09 m/s vs 3.21 m/s; p <0.001) and calcaneofibular ligament (1.99 m/s vs 3.42 m/s; p <0.0001). Conclusion Shear wave elastography shows promise as a reproducible method to quantify ankle ligament stiffness. This study reveals that shear waves velocities of the normal lateral ankle ligaments increased with applied stress compared to the resting state.
Collapse
Affiliation(s)
- Lana H Gimber
- Department of VA - Menlo Park Campus, Uniformed Services University, National Teleradiology Program, United States
| | - L Daniel Latt
- Department of Orthopaedic Surgery, The University of Arizona College of Medicine Banner-University Medical Center, United States
| | - Chelsea Caruso
- Department of Medical Imaging, The University of Arizona College of Medicine Banner-University Medical Center, United States
| | | | | | | | - Mihra S Taljanovic
- Department of Medical Imaging, The University of Arizona College of Medicine Banner-University Medical Center, United States
| |
Collapse
|
18
|
Trube N, Riedel W, Boljen M. How muscle stiffness affects human body model behavior. Biomed Eng Online 2021; 20:53. [PMID: 34078371 PMCID: PMC8170985 DOI: 10.1186/s12938-021-00876-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 04/04/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Active human body models (AHBM) consider musculoskeletal movement and joint stiffness via active muscle truss elements in the finite element (FE) codes in dynamic application. In the latest models, such as THUMS™ Version 5, nearly all human muscle groups are modeled in form of one-dimensional truss elements connecting each joint. While a lot of work has been done to improve the active and passive behavior of this 1D muscle system in the past, the volumetric muscle system of THUMS was modeled in a much more simplified way based on Post Mortem Human Subject (PMHS) test data. The stiffness changing effect of isometric contraction was hardly considered for the volumetric muscle system of whole human body models so far. While previous works considered this aspect for single muscles, the effect of a change in stiffness due to isometric contraction of volumetric muscles on the AHBM behavior and computation time is yet unknown. METHODS In this study, a simplified frontal impact using the THUMS Version 5 AM50 occupant model was simulated. Key parameters to regulate muscle tissue stiffness of solid elements in THUMS were identified for the material model MAT_SIMPLIFIED_FOAM and different stiffness states were predefined for the buttock and thigh. RESULTS During frontal crash, changes in muscle stiffness had an effect on the overall AHBM behavior including expected injury outcome. Changes in muscle stiffness for the thigh and pelvis, as well as for the entire human body model and for strain-rate-dependent stiffness definitions based on literature data had no significant effect on the computation time. DISCUSSION Kinematics, peak impact force and stiffness changes were in general compliance with the literature data. However, different experimental setups had to be considered for comparison, as this topic has not been fully investigated experimentally in automotive applications in the past. Therefore, this study has limitations regarding validation of the frontal impact results. CONCLUSION Variations of default THUMS material model parameters allow an efficient change in stiffness of volumetric muscles for whole AHBM applications. The computation time is unaffected by altering muscle stiffness using the method suggested in this work. Due to a lack of validation data, the results of this work can only be validated with certain limitations. In future works, the default material models of THUMS could be replaced with recently published models to achieve a possibly more biofidelic muscle behavior, which would even allow a functional dependency of the 1D and 3D muscle systems. However, the effect on calculation time and model stability of these models is yet unknown and should be considered in future studies for efficient AHBM applications.
Collapse
Affiliation(s)
- Niclas Trube
- Fraunhofer-Institute for High-Speed Dynamics, Ernst-Mach-Institut, EMI, Ernst-Zermelo-Straße 4, 79104, Freiburg, Germany.
| | - Werner Riedel
- Fraunhofer-Institute for High-Speed Dynamics, Ernst-Mach-Institut, EMI, Ernst-Zermelo-Straße 4, 79104, Freiburg, Germany
| | - Matthias Boljen
- Fraunhofer-Institute for High-Speed Dynamics, Ernst-Mach-Institut, EMI, Ernst-Zermelo-Straße 4, 79104, Freiburg, Germany
| |
Collapse
|
19
|
Tran A, Gao J. Quantitative Ultrasound to Assess Skeletal Muscles in Post Stroke Spasticity. J Cent Nerv Syst Dis 2021; 13:1179573521996141. [PMID: 33746524 PMCID: PMC7940737 DOI: 10.1177/1179573521996141] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 01/25/2021] [Indexed: 12/11/2022] Open
Abstract
Quantitative ultrasound (QUS) techniques such as pixel intensity, ultrasound strain, and shear wave elastography have made it possible to identify the echogenicity (brightness) and mechanical properties (stiffness) of normal and pathological tissues. These techniques can be utilized as an alternative diagnosis tool to assess post stroke spasticity. Current clinical assessment methods include the Modified Ashworth Scale (MAS) and the Modified Tardieu Scale (MTS), which can result in inconsistencies due to their subjective nature. QUS provides robust approaches to assessing muscle stiffness associated with post stroke spasticity. Computer-aided pixel count quantifies tissue echogenicity in grayscale image. A strain ratio in ultrasound strain imaging compares the stiffness and movement (lengthening or shortening) of a spastic muscle with nonspecific muscle. In addition, shear wave elastography provides the shear wave velocity of an affected muscle that directly associated with the muscle stiffness before and after treatment for spasticity. This article reviews the theory behind these aforementioned concepts and discuss the relations between QUS and skeletal muscles in post stroke spasticity.
Collapse
Affiliation(s)
| | - Jing Gao
- Rocky Vista University, Ivins, UT, USA
| |
Collapse
|
20
|
Sowinski DR, McGarry MDJ, Van Houten EEW, Gordon-Wylie S, Weaver JB, Paulsen KD. Poroelasticity as a Model of Soft Tissue Structure: Hydraulic Permeability Reconstruction for Magnetic Resonance Elastography in Silico. FRONTIERS IN PHYSICS 2021; 8:617582. [PMID: 36340954 PMCID: PMC9635531 DOI: 10.3389/fphy.2020.617582] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Magnetic Resonance Elastography allows noninvasive visualization of tissue mechanical properties by measuring the displacements resulting from applied stresses, and fitting a mechanical model. Poroelasticity naturally lends itself to describing tissue - a biphasic medium, consisting of both solid and fluid components. This article reviews the theory of poroelasticity, and shows that the spatial distribution of hydraulic permeability, the ease with which the solid matrix permits the flow of fluid under a pressure gradient, can be faithfully reconstructed without spatial priors in simulated environments. The paper describes an in-house MRE computational platform - a multi-mesh, finite element poroelastic solver coupled to an artificial epistemic agent capable of running Bayesian inference to reconstruct inhomogenous model mechanical property images from measured displacement fields. Building on prior work, the domain of convergence for inference is explored, showing that hydraulic permeabilities over several orders of magnitude can be reconstructed given very little prior knowledge of the true spatial distribution.
Collapse
Affiliation(s)
- Damian R. Sowinski
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States
| | | | | | - Scott Gordon-Wylie
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States
| | - John B Weaver
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States
- Geisel School of Medicine, Dartmouth College, Hanover, NH, United States
- Dartmouth-Hitchcock Medical Center, Department of Radiology, Lebanon, NH, United States
| | - Keith D. Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, NH, United States
- Geisel School of Medicine, Dartmouth College, Hanover, NH, United States
- Dartmouth-Hitchcock Medical Center, Center for Surgical Innovation, Lebanon, NH, United States
| |
Collapse
|
21
|
Shimoyama D, Shitara H, Hamano N, Ichinose T, Sasaki T, Yamamoto A, Kobayashi T, Tajika T, Takagishi K, Chikuda H. Reliability of shoulder muscle stiffness measurement using strain ultrasound elastography and an acoustic coupler. J Med Ultrason (2001) 2020; 48:91-96. [PMID: 33052492 DOI: 10.1007/s10396-020-01056-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 09/15/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE Abnormal increases in muscle tone can be caused by various musculoskeletal disorders. The objective of this study was to evaluate intratester and intertester reliabilities in measuring the stiffness of the shoulder muscles using strain ultrasound elastography (USE) and an acoustic coupler. METHOD Tissue stiffness was measured in the trapezius muscle and in the supraspinatus muscle of healthy young volunteers. RESULTS The mean strain ratios measured by two experienced shoulder surgeons were significantly higher in the trapezius muscle than in the supraspinatus muscle (P < 0.001). Intratester reliability was rated as moderate to substantial for the trapezius muscle and substantial for the supraspinatus muscle. Intertester reliability was substantial for both muscles, with an intraclass correlation coefficient (2,1) of 0.62 [95% confidence interval (CI) 0.28-0.82] for the trapezius muscle and 0.69 (95% CI 0.40-0.86) for the supraspinatus muscle. CONCLUSIONS We found substantial intratester and intertester reliabilities for the trapezius and supraspinatus muscles, suggesting that USE represents a promising modality for measuring the stiffness of shoulder muscles. However, the clinical application of this method will require the development of a device that can standardize the scanning technique to further increase the reliability.
Collapse
Affiliation(s)
- Daisuke Shimoyama
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Hitoshi Shitara
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan.
| | - Noritaka Hamano
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Ichinose
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Sasaki
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Atsushi Yamamoto
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsutomu Kobayashi
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Tsuyoshi Tajika
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Kenji Takagishi
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| | - Hirotaka Chikuda
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma, 371-8511, Japan
| |
Collapse
|
22
|
Bell EA, Hibbert JE, Domire ZJ. Measurement of intrinsic foot stiffness in minimally and traditionally shod runners using ultrasound elastography: A pilot study. J Sports Sci 2020; 38:1516-1523. [PMID: 32228117 DOI: 10.1080/02640414.2020.1746595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Running is an activity with a consistently high injury rate. Running footwear design that mimics barefoot running has been proposed to reduce injury rate by increasing the strength of foot structures. However, there is little evidence to support this. The purpose of the current study is to use shear wave ultrasound elastography to examine material properties (shear modulus) of intrinsic foot structures in experienced minimally and traditionally shod runners. It is hypothesized that minimalist runners will exhibit increased stiffness compared to controls demonstrating the strengthening of these structures. Eighteen healthy runners (8 minimalist and 10 traditionalist), running a minimum of 10 mi · wk-1, participated. Elastography scans were performed on the left foot of each participant. There is no apparent stiffening of foot structures associated with wearing minimalist shoes. Only the FHB tendon is different between shoe types and, contrary to the hypothesis, was stiffer in traditionalist compared to minimalist runners (257.26 ± 51.64 kPa vs 160.88 ± 27.79 kPa, respectively). A moderate positive (r = 0.7) relationship between training load and tendon stiffness suggests strengthening of tendon when running in traditional shoes. If running in minimalist shoes increases loading on these structures without resulting in stronger tissues, it is possible that minimalist footwear may increase injury risk.
Collapse
Affiliation(s)
- Erica A Bell
- Department of Kinesiology, East Carolina University , Greenville, NC, USA
| | - Jamie E Hibbert
- Department of Kinesiology, East Carolina University , Greenville, NC, USA
| | - Zachary J Domire
- Department of Kinesiology, East Carolina University , Greenville, NC, USA
| |
Collapse
|
23
|
Strijkers GJ, Araujo EC, Azzabou N, Bendahan D, Blamire A, Burakiewicz J, Carlier PG, Damon B, Deligianni X, Froeling M, Heerschap A, Hollingsworth KG, Hooijmans MT, Karampinos DC, Loudos G, Madelin G, Marty B, Nagel AM, Nederveen AJ, Nelissen JL, Santini F, Scheidegger O, Schick F, Sinclair C, Sinkus R, de Sousa PL, Straub V, Walter G, Kan HE. Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI. J Neuromuscul Dis 2020; 6:1-30. [PMID: 30714967 PMCID: PMC6398566 DOI: 10.3233/jnd-180333] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Neuromuscular diseases are characterized by progressive muscle degeneration and muscle weakness resulting in functional disabilities. While each of these diseases is individually rare, they are common as a group, and a large majority lacks effective treatment with fully market approved drugs. Magnetic resonance imaging and spectroscopy techniques (MRI and MRS) are showing increasing promise as an outcome measure in clinical trials for these diseases. In 2013, the European Union funded the COST (co-operation in science and technology) action BM1304 called MYO-MRI (www.myo-mri.eu), with the overall aim to advance novel MRI and MRS techniques for both diagnosis and quantitative monitoring of neuromuscular diseases through sharing of expertise and data, joint development of protocols, opportunities for young researchers and creation of an online atlas of muscle MRI and MRS. In this report, the topics that were discussed in the framework of working group 3, which had the objective to: Explore new contrasts, new targets and new imaging techniques for NMD are described. The report is written by the scientists who attended the meetings and presented their data. An overview is given on the different contrasts that MRI can generate and their application, clinical needs and desired readouts, and emerging methods.
Collapse
Affiliation(s)
| | - Ericky C.A. Araujo
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Noura Azzabou
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | | | - Andrew Blamire
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | - Jedrek Burakiewicz
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Pierre G. Carlier
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Bruce Damon
- Vanderbilt University Medical Center, Nashville, USA
| | - Xeni Deligianni
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | | | - Arend Heerschap
- Radboud University Medical Center, Nijmegen, the Netherlands
| | | | | | | | | | | | - Benjamin Marty
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Armin M. Nagel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany & Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | | | - Francesco Santini
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Olivier Scheidegger
- Department of Neurology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Fritz Schick
- University of Tübingen, Section on Experimental Radiology, Tübingen, Germany
| | | | | | | | - Volker Straub
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | | | - Hermien E. Kan
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
24
|
Schrank F, Warmuth C, Görner S, Meyer T, Tzschätzsch H, Guo J, Uca YO, Elgeti T, Braun J, Sack I. Real‐time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises. Magn Reson Med 2019; 84:103-114. [DOI: 10.1002/mrm.28095] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/29/2019] [Accepted: 11/03/2019] [Indexed: 12/17/2022]
Affiliation(s)
- Felix Schrank
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Carsten Warmuth
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Steffen Görner
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Tom Meyer
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Heiko Tzschätzsch
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Jing Guo
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Yavuz Oguz Uca
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Thomas Elgeti
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| | - Jürgen Braun
- Institute of Medical Informatics Charité–Universitätsmedizin Berlin Berlin Germany
| | - Ingolf Sack
- Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
| |
Collapse
|
25
|
|
26
|
Bilston LE, Bolsterlee B, Nordez A, Sinha S. Contemporary image-based methods for measuring passive mechanical properties of skeletal muscles in vivo. J Appl Physiol (1985) 2019; 126:1454-1464. [PMID: 30236053 DOI: 10.1152/japplphysiol.00672.2018] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Skeletal muscles' primary function in the body is mechanical: to move and stabilize the skeleton. As such, their mechanical behavior is a key aspect of their physiology. Recent developments in medical imaging technology have enabled quantitative studies of passive muscle mechanics, ranging from measurements of intrinsic muscle mechanical properties, such as elasticity and viscosity, to three-dimensional muscle architecture and dynamic muscle deformation and kinematics. In this review we summarize the principles and applications of contemporary imaging methods that have been used to study the passive mechanical behavior of skeletal muscles. Elastography measurements can provide in vivo maps of passive muscle mechanical parameters, and both MRI and ultrasound methods are available (magnetic resonance elastography and ultrasound shear wave elastography, respectively). Both have been shown to differentiate between healthy muscle and muscles affected by a broad range of clinical conditions. Detailed muscle architecture can now be depicted using diffusion tensor imaging, which not only is particularly useful for computational modeling of muscle but also has potential in assessing architectural changes in muscle disorders. More dynamic information about muscle mechanics can be obtained using a range of dynamic MRI methods, which characterize the detailed internal muscle deformations during motion. There are several MRI techniques available (e.g., phase-contrast MRI, displacement-encoded MRI, and "tagged" MRI), each of which can be collected in synchrony with muscle motion and postprocessed to quantify muscle deformation. Together, these modern imaging techniques can characterize muscle motion, deformation, mechanical properties, and architecture, providing complementary insights into skeletal muscle function.
Collapse
Affiliation(s)
- Lynne E Bilston
- Neuroscience Research Australia, Randwick, New South Wales , Australia.,Prince of Wales Clinical School, University of New South Wales, Randwick, New South Wales , Australia
| | - Bart Bolsterlee
- Neuroscience Research Australia, Randwick, New South Wales , Australia.,Graduate School of Biomedical Engineering, University of New South Wales , Kensington, New South Wales , Australia
| | - Antoine Nordez
- Health and Rehabilitation Research Institute, Auckland University of Technology , Auckland , New Zealand.,Movement, Interactions, Performance Laboratory (EA 4334), Faculty of Sport Sciences, University of Nantes , Nantes , France
| | - Shantanu Sinha
- Muscle Imaging and Modeling Laboratory, Department of Radiology, University of California , San Diego, California
| |
Collapse
|
27
|
Gonzalez EA, Romero SE, Castaneda B. Real-Time Crawling Wave Sonoelastography for Human Muscle Characterization: Initial Results. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:563-571. [PMID: 30040637 DOI: 10.1109/tuffc.2018.2858658] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Imaging of musculoskeletal tissue dynamics is currently an exploratory field with the goal of aiding rehabilitation and performance evaluation of pathological or asymptomatic patients. In this pilot study, initial elasticity assessments of the biceps brachii were conducted in a novel crawling wave sonoelastography (CWS) system implemented on a research ultrasound instrument with graphical processing unit capabilities, displaying quantitative elasticity values at 4 frames per second. The CWS system computes the tissue stiffness with the generation of an interference pattern from external vibrators, which can overcome depth limitations of imaging systems with internal excitation sources. Validation on gelatin-based phantoms reported low bias of elasticity values (4.7%) at low excitation frequencies. Preliminary results on in vivo muscle characterization are in accordance with average elasticity values for relaxed and contracted tissues found in the literature, as well as for a range of weight loads.
Collapse
|
28
|
Paoletti M, Pichiecchio A, Cotti Piccinelli S, Tasca G, Berardinelli AL, Padovani A, Filosto M. Advances in Quantitative Imaging of Genetic and Acquired Myopathies: Clinical Applications and Perspectives. Front Neurol 2019; 10:78. [PMID: 30804884 PMCID: PMC6378279 DOI: 10.3389/fneur.2019.00078] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 01/21/2019] [Indexed: 12/11/2022] Open
Abstract
In the last years, magnetic resonance imaging (MRI) has become fundamental for the diagnosis and monitoring of myopathies given its ability to show the severity and distribution of pathology, to identify specific patterns of damage distribution and to properly interpret a number of genetic variants. The advances in MR techniques and post-processing software solutions have greatly expanded the potential to assess pathological changes in muscle diseases, and more specifically of myopathies; a number of features can be studied and quantified, ranging from composition, architecture, mechanical properties, perfusion, and function, leading to what is known as quantitative MRI (qMRI). Such techniques can effectively provide a variety of information beyond what can be seen and assessed by conventional MR imaging; their development and application in clinical practice can play an important role in the diagnostic process and in assessing disease course and treatment response. In this review, we briefly discuss the current role of muscle MRI in diagnosing muscle diseases and describe in detail the potential and perspectives of the application of advanced qMRI techniques in this field.
Collapse
Affiliation(s)
- Matteo Paoletti
- Neuroradiology Department, IRCCS Mondino Foundation, Pavia, Italy.,Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy
| | - Anna Pichiecchio
- Neuroradiology Department, IRCCS Mondino Foundation, Pavia, Italy.,Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy
| | - Stefano Cotti Piccinelli
- Unit of Neurology, Center for Neuromuscular Diseases, ASST Spedali Civili and University of Brescia, Brescia, Italy
| | - Giorgio Tasca
- Neurology Department, Dipartimento di Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | | | - Alessandro Padovani
- Unit of Neurology, Center for Neuromuscular Diseases, ASST Spedali Civili and University of Brescia, Brescia, Italy
| | - Massimiliano Filosto
- Unit of Neurology, Center for Neuromuscular Diseases, ASST Spedali Civili and University of Brescia, Brescia, Italy
| |
Collapse
|
29
|
Fovargue D, Nordsletten D, Sinkus R. Stiffness reconstruction methods for MR elastography. NMR IN BIOMEDICINE 2018; 31:e3935. [PMID: 29774974 PMCID: PMC6175248 DOI: 10.1002/nbm.3935] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 03/27/2018] [Accepted: 03/27/2018] [Indexed: 05/19/2023]
Abstract
Assessment of tissue stiffness is desirable for clinicians and researchers, as it is well established that pathophysiological mechanisms often alter the structural properties of tissue. Magnetic resonance elastography (MRE) provides an avenue for measuring tissue stiffness and has a long history of clinical application, including staging liver fibrosis and stratifying breast cancer malignancy. A vital component of MRE consists of the reconstruction algorithms used to derive stiffness from wave-motion images by solving inverse problems. A large range of reconstruction methods have been presented in the literature, with differing computational expense, required user input, underlying physical assumptions, and techniques for numerical evaluation. These differences, in turn, have led to varying accuracy, robustness, and ease of use. While most reconstruction techniques have been validated against in silico or in vitro phantoms, performance with real data is often more challenging, stressing the robustness and assumptions of these algorithms. This article reviews many current MRE reconstruction methods and discusses the aforementioned differences. The material assumptions underlying the methods are developed and various approaches for noise reduction, regularization, and numerical discretization are discussed. Reconstruction methods are categorized by inversion type, underlying assumptions, and their use in human and animal studies. Future directions, such as alternative material assumptions, are also discussed.
Collapse
Affiliation(s)
- Daniel Fovargue
- Imaging Sciences & Biomedical EngineeringKing's College LondonLondonUK
| | - David Nordsletten
- Imaging Sciences & Biomedical EngineeringKing's College LondonLondonUK
| | - Ralph Sinkus
- Imaging Sciences & Biomedical EngineeringKing's College LondonLondonUK
- Inserm U1148, LVTSUniversity Paris Diderot, University Paris 13Paris75018France
| |
Collapse
|
30
|
Guidetti M, Lorgna G, Hammersly M, Lewis P, Klatt D, Vena P, Shah R, Royston TJ. Anisotropic composite material phantom to improve skeletal muscle characterization using magnetic resonance elastography. J Mech Behav Biomed Mater 2018; 89:199-208. [PMID: 30292169 DOI: 10.1016/j.jmbbm.2018.09.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 09/23/2018] [Accepted: 09/24/2018] [Indexed: 12/12/2022]
Abstract
The presence and progression of neuromuscular pathology, including spasticity, Duchenne's muscular dystrophy and hyperthyroidism, has been correlated with changes in the intrinsic mechanical properties of skeletal muscle tissue. Tools for noninvasively measuring and monitoring these properties, such as Magnetic Resonance Elastography (MRE), could benefit basic research into understanding neuromuscular pathologies, as well as translational research to develop therapies, by providing a means of assessing and tracking their efficacy. Dynamic elastography methods for noninvasive measurement of tissue mechanical properties have been under development for nearly three decades. Much of the technological development to date, for both Ultrasound (US)-based and Magnetic Resonance Imaging (MRI)-based strategies, has been grounded in assumptions of local homogeneity and isotropy. Striated skeletal and cardiac muscle, as well as brain white matter and soft tissue in some other organ regions, exhibit a fibrous microstructure which entails heterogeneity and anisotropic response; as one seeks to improve the accuracy and resolution in mechanical property assessment, heterogeneity and anisotropy need to be accounted for in order to optimize both the dynamic elastography experimental protocol and the interpretation of the measurements. Advances in elastography methodology at every step have been aided by the use of tissue-mimicking phantoms. The aim of the present study was to develop and characterize a heterogeneous composite phantom design with uniform controllable anisotropic properties meant to be comparable to the frequency-dependent anisotropic properties of skeletal muscle. MRE experiments and computational finite element (FE) studies were conducted on a novel 3D-printed composite phantom design. The displacement maps obtained from simulation and experiment show the same elliptical shaped wavefronts elongated in the plane where the structure presents higher shear modulus. The model exhibits a degree of anisotropy in line with literature data from skeletal muscle tissue MRE experiments. FE simulations of the MRE experiments provide insight into proper interpretation of experimental measurements, and help to quantify the importance of heterogeneity in the anisotropic material at different scales.
Collapse
Affiliation(s)
- Martina Guidetti
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, 851 South Mogan Street, 212 SEO, Chicago, IL 60607-7052, USA.
| | - Gloria Lorgna
- Department of Chemistry, Materials and Chemical Engineering Giulio Natta, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milan, Italy.
| | - Margaret Hammersly
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA; Simpson Querrey Institute, Northwestern University, Chicago, IL, USA
| | - Phillip Lewis
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA; Simpson Querrey Institute, Northwestern University, Chicago, IL, USA
| | - Dieter Klatt
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, 851 South Mogan Street, 212 SEO, Chicago, IL 60607-7052, USA.
| | - Pasquale Vena
- Department of Chemistry, Materials and Chemical Engineering Giulio Natta, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milan, Italy.
| | - Ramille Shah
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, 851 South Mogan Street, 212 SEO, Chicago, IL 60607-7052, USA; Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA; Simpson Querrey Institute, Northwestern University, Chicago, IL, USA
| | - Thomas J Royston
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, 851 South Mogan Street, 212 SEO, Chicago, IL 60607-7052, USA.
| |
Collapse
|
31
|
Kolipaka A, Wassenaar PA, Cha S, Marashdeh WM, Mo X, Kalra P, Gans B, Raterman B, Bourekas E. Magnetic resonance elastography to estimate brain stiffness: Measurement reproducibility and its estimate in pseudotumor cerebri patients. Clin Imaging 2018; 51:114-122. [PMID: 29459315 PMCID: PMC6087505 DOI: 10.1016/j.clinimag.2018.02.005] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 01/08/2018] [Accepted: 02/02/2018] [Indexed: 01/01/2023]
Abstract
This study determines the reproducibility of magnetic resonance elastography (MRE) derived brain stiffness in normal volunteers and compares it against pseudotumor patients before and after lumbar puncture (LP). MRE was performed on 10 normal volunteers for reproducibility and 14 pseudotumor patients before and after LP. During LP, opening and closing cerebrospinal fluid (CSF) pressures were recorded before and after removal of CSF and correlated to brain stiffness. Stiffness reproducibility was observed (r > 0.78; p < 0.008). Whole brain opening LP stiffness was significantly (p = 0.04) higher than normals, but no significant difference (p = 0.11) in closing LP measurements. No significant correlation was observed between opening and closing pressure and brain stiffness.
Collapse
Affiliation(s)
- Arunark Kolipaka
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
| | - Peter A Wassenaar
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Sangmin Cha
- Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA
| | - Wael M Marashdeh
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Xiaokui Mo
- Center for Biostatistics, The Ohio State University, Columbus, OH, USA
| | - Prateek Kalra
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Bradley Gans
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Brian Raterman
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Eric Bourekas
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| |
Collapse
|
32
|
Pamboris GM, Noorkoiv M, Baltzopoulos V, Gokalp H, Marzilger R, Mohagheghi AA. Effects of an acute bout of dynamic stretching on biomechanical properties of the gastrocnemius muscle determined by shear wave elastography. PLoS One 2018; 13:e0196724. [PMID: 29723229 PMCID: PMC5933711 DOI: 10.1371/journal.pone.0196724] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 04/18/2018] [Indexed: 01/01/2023] Open
Abstract
AIMS The aim of this study was to examine the acute effects of dynamic stretching (DS) exercise on passive ankle range of motion (RoM), resting localized muscle stiffness, as measured by shear wave speed (SWS) of medial gastrocnemius muscle, fascicle strain, and thickness. METHODS/RESULTS Twenty-three participants performed a DS protocol. Before and after stretching, SWS was measured in the belly of the resting medial gastrocnemius muscle (MGM) using shear wave elastography. DS produced small improvements in maximum dorsiflexion (+1.5° ±1.5; mean difference ±90% confidence limits) and maximum plantarflexion (+2.3° ±1.8), a small decrease in fascicle strain (-2.6% ±4.4) and a small increase in SWS at neutral resting angle (+11.4% ±1.5). There was also a small increase in muscle thickness (+4.1mm ±2.0). CONCLUSIONS Through the use of elastography, this is the first study to suggest that DS increases muscle stiffness, decreases fascicle strain and increases muscle thickness as a result of improved RoM. These results can be beneficial to coaches, exercise and clinical scientists when choosing DS as a muscle conditioning or rehabilitation intervention.
Collapse
Affiliation(s)
- George M. Pamboris
- Centre for Human Performance, Exercise and Rehabilitation, Brunel University London, Uxbridge, United Kingdom
| | - Marika Noorkoiv
- Centre for Human Performance, Exercise and Rehabilitation, Brunel University London, Uxbridge, United Kingdom
- Institute of Environment, Health and Societies, Brunel University London, Uxbridge, United Kingdom
| | - Vasilios Baltzopoulos
- Liverpool John Moores University, Research Institute for Sport and Exercise Sciences (RISES), Liverpool, United Kingdom
| | - Hulya Gokalp
- Centre for Human Performance, Exercise and Rehabilitation, Brunel University London, Uxbridge, United Kingdom
| | - Robert Marzilger
- Department of Training and Movement Sciences, Humboldt-Universität zu Berlin, Berlin, Germany
- Berlin School of Movement Sciences, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Amir A. Mohagheghi
- Centre for Human Performance, Exercise and Rehabilitation, Brunel University London, Uxbridge, United Kingdom
- Institute of Environment, Health and Societies, Brunel University London, Uxbridge, United Kingdom
- University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| |
Collapse
|
33
|
Creze M, Soubeyrand M, Yue JL, Gagey O, Maître X, Bellin MF. Magnetic resonance elastography of the lumbar back muscles: A preliminary study. Clin Anat 2018; 31:514-520. [DOI: 10.1002/ca.23065] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 02/07/2018] [Accepted: 02/13/2018] [Indexed: 12/26/2022]
Affiliation(s)
- Maud Creze
- Radiology Department; Bicêtre Hospital; APHP France
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités, IR4M, CNRS, Univ Paris-Sud, Université Paris-Saclay; Orsay France
| | | | - Jin Long Yue
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités, IR4M, CNRS, Univ Paris-Sud, Université Paris-Saclay; Orsay France
- Imagerie Moléculaire In Vivo, IMIV, Inserm, CEA, CNRS, Univ Paris-Sud, Université Paris-Saclay; Orsay France
| | - Olivier Gagey
- Orthopedic Department; Bicêtre Hospital; APHP France
| | - Xavier Maître
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités, IR4M, CNRS, Univ Paris-Sud, Université Paris-Saclay; Orsay France
| | - Marie-France Bellin
- Radiology Department; Bicêtre Hospital; APHP France
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités, IR4M, CNRS, Univ Paris-Sud, Université Paris-Saclay; Orsay France
| |
Collapse
|
34
|
Carlier PG, Marty B, Scheidegger O, Loureiro de Sousa P, Baudin PY, Snezhko E, Vlodavets D. Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials. J Neuromuscul Dis 2018; 3:1-28. [PMID: 27854210 PMCID: PMC5271435 DOI: 10.3233/jnd-160145] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Recent years have seen tremendous progress towards therapy of many previously incurable neuromuscular diseases. This new context has acted as a driving force for the development of novel non-invasive outcome measures. These can be organized in three main categories: functional tools, fluid biomarkers and imagery. In the latest category, nuclear magnetic resonance imaging (NMRI) offers a considerable range of possibilities for the characterization of skeletal muscle composition, function and metabolism. Nowadays, three NMR outcome measures are frequently integrated in clinical research protocols. They are: 1/ the muscle cross sectional area or volume, 2/ the percentage of intramuscular fat and 3/ the muscle water T2, which quantity muscle trophicity, chronic fatty degenerative changes and oedema (or more broadly, “disease activity”), respectively. A fourth biomarker, the contractile tissue volume is easily derived from the first two ones. The fat fraction maps most often acquired with Dixon sequences have proven their capability to detect small changes in muscle composition and have repeatedly shown superior sensitivity over standard functional evaluation. This outcome measure will more than likely be the first of the series to be validated as an endpoint by regulatory agencies. The versatility of contrast generated by NMR has opened many additional possibilities for characterization of the skeletal muscle and will result in the proposal of more NMR biomarkers. Ultra-short TE (UTE) sequences, late gadolinium enhancement and NMR elastography are being investigated as candidates to evaluate skeletal muscle interstitial fibrosis. Many options exist to measure muscle perfusion and oxygenation by NMR. Diffusion NMR as well as texture analysis algorithms could generate complementary information on muscle organization at microscopic and mesoscopic scales, respectively. 31P NMR spectroscopy is the reference technique to assess muscle energetics non-invasively during and after exercise. In dystrophic muscle, 31P NMR spectrum at rest is profoundly perturbed, and several resonances inform on cell membrane integrity. Considerable efforts are being directed towards acceleration of image acquisitions using a variety of approaches, from the extraction of fat content and water T2 maps from one single acquisition to partial matrices acquisition schemes. Spectacular decreases in examination time are expected in the near future. They will reinforce the attractiveness of NMR outcome measures and will further facilitate their integration in clinical research trials.
Collapse
Affiliation(s)
- Pierre G Carlier
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,CEA, DSV, I2BM, MIRCen, NMR Laboratory, Paris, France.,National Academy of Sciences, United Institute for Informatics Problems, Minsk, Belarus
| | - Benjamin Marty
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,CEA, DSV, I2BM, MIRCen, NMR Laboratory, Paris, France
| | - Olivier Scheidegger
- Institute of Myology, Pitie-Salpetriere University Hospital, Paris, France.,Support Center for Advanced Neuroimaging (SCAN), Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, and University of Bern, Switzerland
| | | | | | - Eduard Snezhko
- National Academy of Sciences, United Institute for Informatics Problems, Minsk, Belarus
| | - Dmitry Vlodavets
- N.I. Prirogov Russian National Medical Research University, Clinical Research Institute of Pediatrics, Moscow, Russian Federation
| |
Collapse
|
35
|
Tan L, McGarry MDJ, Van Houten EEW, Ji M, Solamen L, Zeng W, Weaver JB, Paulsen KD. A numerical framework for interstitial fluid pressure imaging in poroelastic MRE. PLoS One 2017; 12:e0178521. [PMID: 28586393 PMCID: PMC5460821 DOI: 10.1371/journal.pone.0178521] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Accepted: 05/15/2017] [Indexed: 11/18/2022] Open
Abstract
A numerical framework for interstitial fluid pressure imaging (IFPI) in biphasic materials is investigated based on three-dimensional nonlinear finite element poroelastic inversion. The objective is to reconstruct the time-harmonic pore-pressure field from tissue excitation in addition to the elastic parameters commonly associated with magnetic resonance elastography (MRE). The unknown pressure boundary conditions (PBCs) are estimated using the available full-volume displacement data from MRE. A subzone-based nonlinear inversion (NLI) technique is then used to update mechanical and hydrodynamical properties, given the appropriate subzone PBCs, by solving a pressure forward problem (PFP). The algorithm was evaluated on a single-inclusion phantom in which the elastic property and hydraulic conductivity images were recovered. Pressure field and material property estimates had spatial distributions reflecting their true counterparts in the phantom geometry with RMS errors around 20% for cases with 5% noise, but degraded significantly in both spatial distribution and property values for noise levels > 10%. When both shear moduli and hydraulic conductivity were estimated along with the pressure field, property value error rates were as high as 58%, 85% and 32% for the three quantities, respectively, and their spatial distributions were more distorted. Opportunities for improving the algorithm are discussed.
Collapse
Affiliation(s)
- Likun Tan
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
| | - Matthew D. J. McGarry
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, United States of America
| | - Elijah E. W. Van Houten
- Department of Mechanical Engineering, University de Sherbrooke, Sherbrooke, Quebec J1K 2R1, Canada
| | - Ming Ji
- Department of Molecular Biology and Genetics, Johns Hopkins University School of Medicine, Baltimore, MD 21205, United States of America
| | - Ligin Solamen
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
| | - Wei Zeng
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
| | - John B. Weaver
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
- Department of Radiology, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 United States of America
| | - Keith D. Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States of America
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756 United States of America
| |
Collapse
|
36
|
Nelissen JL, de Graaf L, Traa WA, Schreurs TJL, Moerman KM, Nederveen AJ, Sinkus R, Oomens CWJ, Nicolay K, Strijkers GJ. A MRI-Compatible Combined Mechanical Loading and MR Elastography Setup to Study Deformation-Induced Skeletal Muscle Damage in Rats. PLoS One 2017; 12:e0169864. [PMID: 28076414 PMCID: PMC5226723 DOI: 10.1371/journal.pone.0169864] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 12/23/2016] [Indexed: 02/01/2023] Open
Abstract
Deformation of skeletal muscle in the proximity of bony structures may lead to deep tissue injury category of pressure ulcers. Changes in mechanical properties have been proposed as a risk factor in the development of deep tissue injury and may be useful as a diagnostic tool for early detection. MRE allows for the estimation of mechanical properties of soft tissue through analysis of shear wave data. The shear waves originate from vibrations induced by an external actuator placed on the tissue surface. In this study a combined Magnetic Resonance (MR) compatible indentation and MR Elastography (MRE) setup is presented to study mechanical properties associated with deep tissue injury in rats. The proposed setup allows for MRE investigations combined with damage-inducing large strain indentation of the Tibialis Anterior muscle in the rat hind leg inside a small animal MR scanner. An alginate cast allowed proper fixation of the animal leg with anatomical perfect fit, provided boundary condition information for FEA and provided good susceptibility matching. MR Elastography data could be recorded for the Tibialis Anterior muscle prior to, during, and after indentation. A decaying shear wave with an average amplitude of approximately 2 μm propagated in the whole muscle. MRE elastograms representing local tissue shear storage modulus Gd showed significant increased mean values due to damage-inducing indentation (from 4.2 ± 0.1 kPa before to 5.1 ± 0.6 kPa after, p<0.05). The proposed setup enables controlled deformation under MRI-guidance, monitoring of the wound development by MRI, and quantification of tissue mechanical properties by MRE. We expect that improved knowledge of changes in soft tissue mechanical properties due to deep tissue injury, will provide new insights in the etiology of deep tissue injuries, skeletal muscle damage and other related muscle pathologies.
Collapse
Affiliation(s)
- Jules L. Nelissen
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
- * E-mail:
| | - Larry de Graaf
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Willeke A. Traa
- Soft Tissue Biomechanics and Engineering, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Tom J. L. Schreurs
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
| | - Kevin M. Moerman
- Center for Extreme Bionics, Media lab, MIT, Cambridge, MA, United States of America
| | - Aart J. Nederveen
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Ralph Sinkus
- Image Sciences & Biomedical Engineering, King’s College London, London, United Kingdom
| | - Cees W. J. Oomens
- Soft Tissue Biomechanics and Engineering, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Klaas Nicolay
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Gustav J. Strijkers
- Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
37
|
Hong SH, Hong SJ, Yoon JS, Oh CH, Cha JG, Kim HK, Bolster B. Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3 T MRI system. Acta Radiol 2016; 57:1099-106. [PMID: 25711231 DOI: 10.1177/0284185115571987] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Accepted: 01/17/2015] [Indexed: 12/24/2022]
Abstract
BACKGROUND Magnetic resonance elastography (MRE) at 3 T MR has the potential to improve the objective detection of skeletal muscle stiffness. PURPOSE To determine the feasibility of MRE using 3 T MR for measurement of the stiffness of shoulder muscles in subjects. MATERIAL AND METHODS This study prospectively evaluated 16 healthy subjects (mean age, 29.8 years; range, 25-51 years). MRE was acquired with 3 T MR through the use of a 2D-gradient-echo-based MRE sequence at two different excitation frequencies (90 and 120 Hz). The mean stiffness values (MSV) of the trapezius and infraspinatus muscles were measured by two radiologists. Differences between the MSV in the x, y, and z motion-sensitization directions were assessed. Inter-observer agreement was also measured. RESULTS The MSV of the trapezius muscle were 2.72 kPa ± 0.6 (SD) at 90 Hz and 4.66 kPa ± 1.2 at 120 Hz, while the MSV for the infraspinatus muscle were 3.2 kPa ± 0.52 at 90 Hz and 4.38 kPa ± 0.92 at 120 Hz. The MSV for both muscles were significantly higher at 120 Hz than at 90 Hz (P < 0.05). The MSV in the three different directions were significantly different from each other in the infraspinatus muscle (P < 0.05). Levels of inter-observer agreement regarding MSV were good to excellent for both the trapezius (intraclass correlation coefficient [ICC] = 0.979-0.996) and infraspinatus muscles (ICC = 0.614-0.943). CONCLUSION MRE at 3 T is a feasible technique for the evaluation of shoulder muscle stiffness. Extended application of skeletal muscle MRE at 3 T will contribute to the evaluation and treatment of skeletal muscle disorders.
Collapse
Affiliation(s)
- Sun Hwa Hong
- Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Suk-Joo Hong
- Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Joon-Shik Yoon
- Department of Rehabilitation Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea
| | - Chang-Hyun Oh
- Department of Electronics & Information Engineering and Korea Artificial Organ Center, Korea University, Seoul, Republic of Korea
| | - Jang Gyu Cha
- Department of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon-Si, Republic of Korea
| | - Hee Kyung Kim
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | | |
Collapse
|
38
|
Lefebvre PM, Koon KTV, Brusseau E, Nicolle S, Palieme JF, Lambert SA, Grenier D. Comparison of viscoelastic property characterization of plastisol phantoms with magnetic resonance elastography and high-frequency rheometry. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:1216-1219. [PMID: 28268544 DOI: 10.1109/embc.2016.7590924] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This study aims at evaluating Magnetic Resonance Elastography (MRE) as a reliable technique for the characterization of viscoelastic properties of soft tissues. Three phantoms with different concentrations of plastisol and softener were prepared in order to mechanically mimic a broad panel of healthy and pathological soft tissues. Once placed in a MRI device, each sample was excited by a homemade external driver, inducing shear waves within the medium. The storage (G') and loss (G") moduli of each phantom were then reconstructed from MRE acquisitions over a frequency range from 300 to 1,000 Hz, by applying a 2D Helmholtz inversion algorithm. At the same time, mechanical tests were performed on four samples of each phantom with a High-Frequency piezo-Rheometer (HFR) over an overlapping frequency range (from 160 to 630 Hz) with the same test conditions (temperature, ageing). The comparison between both techniques shows a good agreement in the measurement of the storage and loss moduli, underlying the capability of MRE to noninvasively assess the complex shear modulus G* of a medium and its interest for investigating the viscoelastic properties of living tissues. Moreover, the phantoms with varying concentrations of plastisol used in this study show interesting rheological properties, which make them good candidates to simulate the broad variety of viscoelastic behaviors of healthy and pathological soft tissues.
Collapse
|
39
|
Chatelin S, Charpentier I, Corbin N, Meylheuc L, Vappou J. An automatic differentiation-based gradient method for inversion of the shear wave equation in magnetic resonance elastography: specific application in fibrous soft tissues. Phys Med Biol 2016; 61:5000-19. [PMID: 27300107 DOI: 10.1088/0031-9155/61/13/5000] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Quantitative and accurate measurement of in vivo mechanical properties using dynamic elastography has been the scope of many research efforts over the past two decades. Most of the shear-wave-based inverse approaches for magnetic resonance elastography (MRE) make the assumption of isotropic viscoelasticity. In this paper, we propose a quantitative gradient method for inversion of the shear wave equation in anisotropic media derived from a full waveform description using analytical viscoelastic Green formalism and automatic differentiation. The abilities and performances of the proposed identification method are first evaluated on numerical phantoms calculated in a transversely isotropic medium, and subsequently on experimental MRE data measured on an isotropic hydrogel phantom, on an anisotropic cryogel phantom and on an ex vivo fibrous muscle. The experiments are carried out by coupling circular shear wave profiles generated by acoustic radiation force and MRE acquisition of the wave front. Shear modulus values obtained by our MRE method are compared to those obtained by rheometry in the isotropic hydrogel phantom, and are found to be in good agreement despite non-overlapping frequency ranges. Both the cryogel and the ex vivo muscle are found to be anisotropic. Stiffness values in the longitudinal direction are found to be 1.8 times and 1.9 times higher than those in the transverse direction for the cryogel and the muscle, respectively. The proposed method shows great perspectives and substantial benefits for the in vivo quantitative investigation of complex mechanical properties in fibrous soft tissues.
Collapse
Affiliation(s)
- Simon Chatelin
- ICube, University of Strasbourg, CNRS, IHU Strasbourg, France
| | | | | | | | | |
Collapse
|
40
|
Barsotti S, Zampa V, Talarico R, Minichilli F, Ortori S, Iacopetti V, D'ascanio A, Tavoni AG, Bombardieri S, Mosca M, Neri R. Thigh magnetic resonance imaging for the evaluation of disease activity in patients with idiopathic inflammatory myopathies followed in a single center. Muscle Nerve 2016; 54:666-72. [PMID: 27279002 DOI: 10.1002/mus.25099] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 02/26/2016] [Accepted: 03/07/2016] [Indexed: 11/06/2022]
Abstract
INTRODUCTION In patients with idiopathic inflammatory myopathies (IIM), magnetic resonance imaging (MRI) has been proposed as a useful tool for diagnosis and follow-up. It may identify muscle inflammation (edema) and fatty infiltration for evaluation of disease activity and damage. Little information is available on the role of MRI in assessment of large cohorts of adult patients with IIM. METHODS Fifty-one patients underwent MRI of the thigh muscles, laboratory tests, and clinical evaluation, including Physician Global Assessment (PGA) of myositis activity and the Manual Muscle Test 8 (MMT8). RESULTS Muscle edema correlated significantly with creatine kinase values (P = 0.017) and PGA (P < 0.001). A significant correlation between edema and MMT8 values (P = 0.025) was observed when patients with muscle fatty infiltration were excluded. With respect to clinical diagnosis, the sensitivity of MRI was 92.3%, and specificity was 83.3%. CONCLUSIONS MRI appears to provide additional information that complements clinical and biochemical examinations. Muscle Nerve 54: 666-672, 2016.
Collapse
Affiliation(s)
- Simone Barsotti
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy. .,Genetic, Oncology and Clinical Medicine doctorate, University of Siena, Siena, Italy.
| | - Virna Zampa
- Department of Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, 56126, Pisa, Italy
| | - Rosaria Talarico
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Fabrizio Minichilli
- Unit of Environmental Epidemiology, Institute of Clinical Physiology, National Council of Research, Pisa, Italy
| | - Simona Ortori
- Department of Diagnostic and Interventional Radiology, University of Pisa, Via Roma 67, 56126, Pisa, Italy
| | - Valentina Iacopetti
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Anna D'ascanio
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | | | - Stefano Bombardieri
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Marta Mosca
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Rossella Neri
- Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| |
Collapse
|
41
|
Silva MET, Brandão S, Parente MPL, Mascarenhas T, Natal Jorge RM. Establishing the biomechanical properties of the pelvic soft tissues through an inverse finite element analysis using magnetic resonance imaging. Proc Inst Mech Eng H 2016; 230:298-309. [DOI: 10.1177/0954411916630571] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Accepted: 01/12/2016] [Indexed: 12/16/2022]
Abstract
The mechanical characteristics of the female pelvic floor are relevant when explaining pelvic dysfunction. The decreased elasticity of the tissue often causes inability to maintain urethral position, also leading to vaginal and rectal descend when coughing or defecating as a response to an increase in the internal abdominal pressure. These conditions can be associated with changes in the mechanical properties of the supportive structures—namely, the pelvic floor muscles—including impairment. In this work, we used an inverse finite element analysis to calculate the material constants for the passive mechanical behavior of the pelvic floor muscles. The numerical model of the pelvic floor muscles and bones was built from magnetic resonance axial images acquired at rest. Muscle deformation, simulating the Valsalva maneuver with a pressure of 4 KPa, was compared with the muscle displacement obtained through additional dynamic magnetic resonance imaging. The difference in displacement was of 0.15 mm in the antero-posterior direction and 3.69 mm in the supero-inferior direction, equating to a percentage error of 7.0% and 16.9%, respectively. We obtained the shortest difference in the displacements using an iterative process that reached the material constants for the Mooney–Rivlin constitutive model ( c10=11.8 KPa and c20=5.53 E−02 KPa). For each iteration, the orthogonal distance between each node from the group of nodes which defined the puborectal muscle in the numerical model versus dynamic magnetic resonance imaging was computed. With the methodology used in this work, it was possible to obtain in vivo biomechanical properties of the pelvic floor muscles for a specific subject using input information acquired non-invasively.
Collapse
Affiliation(s)
- MET Silva
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| | - S Brandão
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
- Department of Radiology, Centro Hospitalar de São João—EPE, Faculty of Medicine, University of Porto, Porto, Portugal
| | - MPL Parente
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| | - T Mascarenhas
- Department of Gynecology and Obstetrics, Centro Hospitalar de São João—EPE, Faculty of Medicine, University of Porto, Porto, Portugal
| | - RM Natal Jorge
- LAETA-INEGI, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
42
|
Low G, Kruse SA, Lomas DJ. General review of magnetic resonance elastography. World J Radiol 2016; 8:59-72. [PMID: 26834944 PMCID: PMC4731349 DOI: 10.4329/wjr.v8.i1.59] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/14/2015] [Accepted: 12/04/2015] [Indexed: 02/06/2023] Open
Abstract
Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing “virtual palpation”, MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration.
Collapse
|
43
|
Dao TT, Pouletaut P, Charleux F, Tho MCHB, Bensamoun S. Analysis of shear wave propagation derived from MR elastography in 3D thigh skeletal muscle using subject specific finite element model. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:4026-9. [PMID: 25570875 DOI: 10.1109/embc.2014.6944507] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this study was to develop a subject specific finite element model derived from MRI images to numerically analyze the MRE (magnetic resonance elastography) shear wave propagation within skeletal thigh muscles. A sagittal T2 CUBE MRI sequence was performed on the 20-cm thigh segment of a healthy male subject. Skin, adipose tissue, femoral bone and 11 muscles were manually segmented in order to have 3D smoothed solid and meshed models. These tissues were modeled with different constitutive laws. A transient modal dynamics analysis was applied to simulate the shear wave propagation within the thigh tissues. The effects of MRE experimental parameters (frequency, force) and the muscle material properties (shear modulus: C10) were analyzed through the simulated shear wave displacement within the vastus medialis muscle. The results showed a plausible range of frequencies (from 90Hz to 120 Hz), which could be used for MRE muscle protocol. The wave amplitude increased with the level of the force, revealing the importance of the boundary condition. Moreover, different shear displacement patterns were obtained as a function of the muscle mechanical properties. The present study is the first to analyze the shear wave propagation in skeletal muscles using a 3D subject specific finite element model. This study could be of great value to assist the experimenters in the set-up of MRE protocols.
Collapse
|
44
|
Chakouch MK, Charleux F, Bensamoun SF. Quantifying the Elastic Property of Nine Thigh Muscles Using Magnetic Resonance Elastography. PLoS One 2015; 10:e0138873. [PMID: 26397730 PMCID: PMC4580449 DOI: 10.1371/journal.pone.0138873] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Accepted: 09/05/2015] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Pathologies of the muscles can manifest different physiological and functional changes. To adapt treatment, it is necessary to characterize the elastic property (shear modulus) of single muscles. Previous studies have used magnetic resonance elastography (MRE), a technique based on MRI technology, to analyze the mechanical behavior of healthy and pathological muscles. The purpose of this study was to develop protocols using MRE to determine the shear modulus of nine thigh muscles at rest. METHODS Twenty-nine healthy volunteers (mean age = 26 ± 3.41 years) with no muscle abnormalities underwent MRE tests (1.5 T MRI). Five MRE protocols were developed to quantify the shear moduli of the nine following thigh muscles at rest: rectus femoris (RF), vastus medialis (VM), vastus intermedius (VI), vastus lateralis (VL), sartorius (Sr), gracilis (Gr), semimembranosus (SM), semitendinosus (ST), and biceps (BC). In addition, the shear modulus of the subcutaneous adipose tissue was analyzed. RESULTS The gracilis, sartorius, and semitendinosus muscles revealed a significantly higher shear modulus (μ_Gr = 6.15 ± 0.45 kPa, μ_ Sr = 5.15 ± 0.19 kPa, and μ_ ST = 5.32 ± 0.10 kPa, respectively) compared to other tissues (from μ_ RF = 3.91 ± 0.16 kPa to μ_VI = 4.23 ± 0.25 kPa). Subcutaneous adipose tissue had the lowest value (μ_adipose tissue = 3.04 ± 0.12 kPa) of all the tissues tested. CONCLUSION The different elasticities measured between the tissues may be due to variations in the muscles' physiological and architectural compositions. Thus, the present protocol could be applied to injured muscles to identify their behavior of elastic property. Previous studies on muscle pathology found that quantification of the shear modulus could be used as a clinical protocol to identify pathological muscles and to follow-up effects of treatments and therapies. These data could also be used for modelling purposes.
Collapse
Affiliation(s)
- Mashhour K. Chakouch
- Biomechanics and Bioengineering Laboratory, UMR CNRS 7338, Sorbonne University, Université de Technologie de Compiègne, Compiègne, France
| | | | - Sabine F. Bensamoun
- Biomechanics and Bioengineering Laboratory, UMR CNRS 7338, Sorbonne University, Université de Technologie de Compiègne, Compiègne, France
- * E-mail:
| |
Collapse
|
45
|
Dubois G, Kheireddine W, Vergari C, Bonneau D, Thoreux P, Rouch P, Tanter M, Gennisson JL, Skalli W. Reliable protocol for shear wave elastography of lower limb muscles at rest and during passive stretching. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2284-2291. [PMID: 26129731 DOI: 10.1016/j.ultrasmedbio.2015.04.020] [Citation(s) in RCA: 86] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 01/26/2015] [Accepted: 04/27/2015] [Indexed: 06/04/2023]
Abstract
Development of shear wave elastography gave access to non-invasive muscle stiffness assessment in vivo. The aim of the present study was to define a measurement protocol to be used in clinical routine for quantifying the shear modulus of lower limb muscles. Four positions were defined to evaluate shear modulus in 10 healthy subjects: parallel to the fibers, in the anterior and posterior aspects of the lower limb, at rest and during passive stretching. Reliability was first evaluated on two muscles by three operators; these measurements were repeated six times. Then, measurement reliability was compared in 11 muscles by two operators; these measurements were repeated three times. Reproducibility of shear modulus was 0.48 kPa and repeatability was 0.41 kPa, with all muscles pooled. Position did not significantly influence reliability. Shear wave elastography appeared to be an appropriate and reliable tool to evaluate the shear modulus of lower limb muscles with the proposed protocol.
Collapse
Affiliation(s)
- Guillaume Dubois
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France.
| | - Walid Kheireddine
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France
| | - Claudio Vergari
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France
| | - Dominique Bonneau
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France
| | - Patricia Thoreux
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France; Universite Paris XIII, Paris, France
| | - Philippe Rouch
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France
| | - Mickael Tanter
- Institut Langevin, Laboratoire Ondes et Acoustique, CNRS UMR 7587, ESPCI ParisTech, PSL, INSERM ERL U979, Paris, France
| | - Jean-Luc Gennisson
- Institut Langevin, Laboratoire Ondes et Acoustique, CNRS UMR 7587, ESPCI ParisTech, PSL, INSERM ERL U979, Paris, France
| | - Wafa Skalli
- LBM/Institut de Biomécanique Humaine Georges Charpark, Arts et Métiers ParisTech, 151 Boulevard de l'Hôpital, Paris 75013, France
| |
Collapse
|
46
|
Guo J, Hirsch S, Scheel M, Braun J, Sack I. Three-parameter shear wave inversion in MR elastography of incompressible transverse isotropic media: Application to in vivo lower leg muscles. Magn Reson Med 2015; 75:1537-45. [PMID: 25988407 DOI: 10.1002/mrm.25740] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 03/12/2015] [Accepted: 03/24/2015] [Indexed: 12/25/2022]
Abstract
PURPOSE To develop and demonstrate MR elastography (MRE) for the measurement of three independent viscoelastic constants of skeletal muscle according to the theory of linear elasticity of incompressible materials with transverse isotropy (TI). METHODS Three-dimensional multifrequency MRE was applied to soleus, gastrocnemius, and tibialis anterior muscles in 10 healthy volunteers. The rotational wave fields were solved for complex-valued viscoelastic parameters μ12, μ13, and E3 corresponding to two shear moduli (within the planes of isotropy and symmetry of TI materials) and Young's modulus (along the principal fiber axis). RESULTS Anisotropy was represented by the inequality μ12 < μ13 < 1/3E3 considering storage and loss properties of the soleus and gastrocnemius muscles, whereas storage shear moduli of tibialis were indistinguishable. Storage moduli were: 1.06 ± 0.12, 1.33 ± 0.10, 6.92 ± 0.95 kPa (soleus); 0.90 ± 0.11, 1.30 ± 0.15, 8.22 ± 1.37 kPa (gastrocnemius); 1.26 ± 0.16, 1.27 ± 0.11, 9.29 ± 1.42 kPa (tibialis), for μ12, μ13, and E3, respectively. The muscles were different in their μ12 and E3 values, whereas μ13 was less sensitive to the muscle type. Leg differences were observed in the soleus and gastrocnemius muscles. CONCLUSION Recovery of the full elasticity tensor in incompressible TI materials is feasible by three-dimensional inversion of the time-harmonic shear wave equation. The method is potentially useful for the clinical evaluation of skeletal muscle anisotropy.
Collapse
Affiliation(s)
- Jing Guo
- Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Sebastian Hirsch
- Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Michael Scheel
- Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| |
Collapse
|
47
|
Bulte JWM. Science to Practice: can MR relaxation and diffusion measurements be used to detect in vivo differentiation of transplanted muscle precursor cells? Radiology 2015; 274:629-31. [PMID: 25710336 DOI: 10.1148/radiol.14142753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Tissue magnetic resonance (MR) relaxometry and diffusion measurements were successfully used to detect the differentiation of implanted human muscle precursor cells (MPCs) into mature skeletal muscle. As no contrast agents are required, this label-free imaging approach may be immediately used in patients to evaluate the outcome of stem cell- and progenitor cell-based therapies aimed to restore defunct muscle.
Collapse
Affiliation(s)
- Jeff W M Bulte
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Cellular Imaging Section, Institute for Cell Engineering, The Johns Hopkins University School of Medicine 720 Rutland Ave, 217 Traylor Baltimore, MD 21205
| |
Collapse
|
48
|
Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury. Adv Skin Wound Care 2015; 28:59-68. [DOI: 10.1097/01.asw.0000460127.47415.6e] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
49
|
Bensamoun S, Charleux F, Debernard L, Themar-Noel C, Voit T. Elastic properties of skeletal muscle and subcutaneous tissues in Duchenne muscular dystrophy by magnetic resonance elastography (MRE): A feasibility study. Ing Rech Biomed 2015. [DOI: 10.1016/j.irbm.2014.11.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
50
|
Chakouch MK, Charleux F, Bensamoun SF. New magnetic resonance elastography protocols to characterise deep back and thigh muscles. Comput Methods Biomech Biomed Engin 2014; 17 Suppl 1:32-3. [PMID: 25074150 DOI: 10.1080/10255842.2014.931086] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- M K Chakouch
- a Laboratoire de Biomécanique et Bioingénierie , UMR CNRS 7338, Université de Technologie de Compiègne, Compiègne, France
| | | | | |
Collapse
|