1
|
Bao Q, Liu X, Xu J, Xia L, Otikovs M, Xie H, Liu K, Zhang Z, Zhou X, Liu C. Unsupervised deep learning model for correcting Nyquist ghosts of single-shot spatiotemporal encoding. Magn Reson Med 2024; 91:1368-1383. [PMID: 38073072 DOI: 10.1002/mrm.29925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 10/20/2023] [Accepted: 10/25/2023] [Indexed: 02/03/2024]
Abstract
PURPOSE To design an unsupervised deep learning (DL) model for correcting Nyquist ghosts of single-shot spatiotemporal encoding (SPEN) and evaluate the model for real MRI applications. METHODS The proposed method consists of three main components: (1) an unsupervised network that combines Residual Encoder and Restricted Subspace Mapping (RERSM-net) and is trained to generate a phase-difference map based on the even and odd SPEN images; (2) a spin physical forward model to obtain the corrected image with the learned phase difference map; and (3) cycle-consistency loss that is explored for training the RERSM-net. RESULTS The proposed RERSM-net could effectively generate smooth phase difference maps and correct Nyquist ghosts of single-shot SPEN. Both simulation and real in vivo MRI experiments demonstrated that our method outperforms the state-of-the-art SPEN Nyquist ghost correction method. Furthermore, the ablation experiments of generating phase-difference maps show the advantages of the proposed unsupervised model. CONCLUSION The proposed method can effectively correct Nyquist ghosts for the single-shot SPEN sequence.
Collapse
Affiliation(s)
- Qingjia Bao
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
| | - Xinjie Liu
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Jingyun Xu
- School of Information Engineering, Wuhan University of Technology, Wuhan, China
| | - Liyang Xia
- School of Information Engineering, Wuhan University of Technology, Wuhan, China
| | | | - Han Xie
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
| | - Kewen Liu
- School of Information Engineering, Wuhan University of Technology, Wuhan, China
| | - Zhi Zhang
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
- University of Chinese Academy of Sciences, Beijing, China
- Optics Valley Laboratory, Wuhan, China
| | - Chaoyang Liu
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, China
- University of Chinese Academy of Sciences, Beijing, China
- Optics Valley Laboratory, Wuhan, China
| |
Collapse
|
2
|
Tian Y, Nayak KS. Real-time water/fat imaging at 0.55T with spiral out-in-out-in sampling. Magn Reson Med 2024; 91:649-659. [PMID: 37815020 PMCID: PMC10841523 DOI: 10.1002/mrm.29885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 08/23/2023] [Accepted: 09/21/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE To develop an efficient and flexible water/fat separated real-time MRI (RT-MRI) method using spiral out-in-out-in (OIOI) sampling and balanced SSFP (bSSFP) at 0.55T. METHODS A bSSFP sequence with golden-angle spiral OIOI readout was developed, capturing three echoes to allow water/fat separation. A low-latency reconstruction that combines all echoes was available for online visualization. An offline reconstruction provided water and fat RT-MRI in two steps: (1) image reconstruction with spatiotemporally constrained reconstruction (STCR) and (2) water/fat separation with hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (HIDEAL). In healthy volunteers, spiral OIOI was acquired in the wrist during a radial-to-ulnar deviation maneuver, in the heart without breath-hold and cardiac gating, and in the lower abdomen during free-breathing for visualizing small bowel motility. RESULTS We demonstrate successful water/fat separated RT-MRI for all tested applications. In the wrist, resulting images provided clear depiction of ligament gaps and their interactions during the radial-to-ulnar deviation maneuver. In the heart, water/fat RT-MRI depicted epicardial fat, provided improved delineation of epicardial coronary arteries, and provided high blood-myocardial contrast for ventricular function assessment. In the abdomen, water-only RT-MRI captured small bowel mobility clearly with improved water-fat contrast. CONCLUSIONS We have demonstrated a novel and flexible bSSFP spiral OIOI sequence at 0.55T that can provide water/fat separated RT-MRI with a variety of application-specific temporal resolution and spatial resolution requirements.
Collapse
Affiliation(s)
- Ye Tian
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
| | - Krishna S. Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
3
|
Daudé P, Roussel T, Troalen T, Viout P, Hernando D, Guye M, Kober F, Confort Gouny S, Bernard M, Rapacchi S. Comparative review of algorithms and methods for chemical-shift-encoded quantitative fat-water imaging. Magn Reson Med 2024; 91:741-759. [PMID: 37814776 DOI: 10.1002/mrm.29860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 08/19/2023] [Accepted: 08/21/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE To propose a standardized comparison between state-of-the-art open-source fat-water separation algorithms for proton density fat fraction (PDFF) andR 2 * $$ {R}_2^{\ast } $$ quantification using an open-source multi-language toolbox. METHODS Eight recent open-source fat-water separation algorithms were compared in silico, in vitro, and in vivo. Multi-echo data were synthesized with varying fat-fractions, B0 off-resonance, SNR and TEs. Experimental evaluation was conducted using calibrated fat-water phantoms acquired at 3T and multi-site open-source phantoms data. Algorithms' performances were observed on challenging in vivo datasets at 3T. Finally, reconstruction algorithms were investigated with different fat spectra to evaluate the importance of the fat model. RESULTS In silico and in vitro results proved most algorithms to be not sensitive to fat-water swaps andB 0 $$ {\mathrm{B}}_0 $$ offsets with five or more echoes. However, two methods remained inaccurate even with seven echoes and SNR = 50, and two other algorithms' precision depended on the echo spacing scheme (p < 0.05). The remaining four algorithms provided reliable performances with limits of agreement under 2% for PDFF and 6 s-1 forR 2 * $$ {R}_2^{\ast } $$ . The choice of fat spectrum model influenced quantification of PDFF mildly (<2% bias) and ofR 2 * $$ {R}_2^{\ast } $$ more severely, with errors up to 20 s-1 . CONCLUSION In promoting standardized comparisons of MRI-based fat and iron quantification using chemical-shift encoded multi-echo methods, this benchmark work has revealed some discrepancies between recent approaches for PDFF andR 2 * $$ {R}_2^{\ast } $$ mapping. Explicit choices and parameterization of the fat-water algorithm appear necessary for reproducibility. This open-source toolbox further enables the user to optimize acquisition parameters by predicting algorithms' margins of errors.
Collapse
Affiliation(s)
- Pierre Daudé
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Tangi Roussel
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | | | - Patrick Viout
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Diego Hernando
- Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Maxime Guye
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Frank Kober
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Sylviane Confort Gouny
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Monique Bernard
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Stanislas Rapacchi
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| |
Collapse
|
4
|
Zhang J, Nguyen TD, Solomon E, Li C, Zhang Q, Li J, Zhang H, Spincemaille P, Wang Y. mcLARO: Multi-contrast learned acquisition and reconstruction optimization for simultaneous quantitative multi-parametric mapping. Magn Reson Med 2024; 91:344-356. [PMID: 37655444 DOI: 10.1002/mrm.29854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 08/14/2023] [Accepted: 08/15/2023] [Indexed: 09/02/2023]
Abstract
PURPOSE To develop a method for rapid sub-millimeter T1 , T2 ,T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and QSM mapping in a single scan using multi-contrast learned acquisition and reconstruction optimization (mcLARO). METHODS A pulse sequence was developed by interleaving inversion recovery and T2 magnetization preparations and single-echo and multi-echo gradient echo acquisitions, which sensitized k-space data to T1 , T2 ,T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and magnetic susceptibility. The proposed mcLARO optimized both the multi-contrast k-space under-sampling pattern and image reconstruction based on image feature fusion using a deep learning framework. The proposed mcLARO method withR = 8 $$ R=8 $$ under-sampling was validated in a retrospective ablation study and compared with other deep learning reconstruction methods, including MoDL and Wave-MoDL, using fully sampled data as reference. Various under-sampling ratios in mcLARO were investigated. mcLARO was also evaluated in a prospective study using separately acquired conventionally sampled quantitative maps as reference standard. RESULTS The retrospective ablation study showed improved image sharpness of mcLARO compared to the baseline network without the multi-contrast sampling pattern optimization or image feature fusion module. The under-sampling ratio experiment showed that higher under-sampling ratios resulted in blurrier images and lower precision of quantitative values. The prospective study showed that small or negligible bias and narrow 95% limits of agreement on regional T1 , T2 ,T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and QSM values by mcLARO (5:39 mins) compared to reference scans (40:03 mins in total). mcLARO outperformed MoDL and Wave-MoDL in terms of image sharpness, noise suppression, and artifact removal. CONCLUSION mcLARO enabled fast sub-millimeter T1 , T2 ,T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and QSM mapping in a single scan.
Collapse
Affiliation(s)
- Jinwei Zhang
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Thanh D Nguyen
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Eddy Solomon
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Chao Li
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
- Department of Applied Physics, Cornell University, Ithaca, New York, USA
| | - Qihao Zhang
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Jiahao Li
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Hang Zhang
- Department of Electrical and Computer Engineering, Cornell University, Ithaca, New York, USA
| | | | - Yi Wang
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| |
Collapse
|
5
|
Peng H, Cheng C, Wan Q, Liang D, Liu X, Zheng H, Zou C. Reducing the ambiguity of field inhomogeneity and chemical shift effect for fat-water separation by field factor. Magn Reson Med 2023; 90:1830-1843. [PMID: 37379480 DOI: 10.1002/mrm.29774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 05/16/2023] [Accepted: 06/03/2023] [Indexed: 06/30/2023]
Abstract
PURPOSE To reduce the ambiguity between chemical shift and field inhomogeneity with flexible TE combinations by introducing a variable (field factor). THEORY AND METHODS The ambiguity between chemical shift and field inhomogeneity can be eliminated directly from the multiple in-phase images acquired at different TEs; however, it is only applicable to few echo combinations. In this study, we accommodated such an implementation in flexible TE combinations by introducing a new variable (field factor). The effects of the chemical shift were removed from the field inhomogeneity in the candidate solutions, thus reducing the ambiguity problem. To validate this concept, multi-echo MRI data acquired from various anatomies with different imaging parameters were tested. The derived fat and water images were compared with those of the state-of-the-art fat-water separation algorithms. RESULTS Robust fat-water separation was achieved with the accurate solution of field inhomogeneity, and no apparent fat-water swap was observed. In addition to the good performance, the proposed method is applicable to various fat-water separation applications, including different sequence types and flexible TE choices. CONCLUSION We propose an algorithm to reduce the ambiguity of chemical shift and field inhomogeneity and achieved robust fat-water separation in various applications.
Collapse
Affiliation(s)
- Hao Peng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Chuanli Cheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qian Wan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Chao Zou
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
6
|
Meneses JP, Arrieta C, Della Maggiora G, Besa C, Urbina J, Arrese M, Gana JC, Galgani JE, Tejos C, Uribe S. Liver PDFF estimation using a multi-decoder water-fat separation neural network with a reduced number of echoes. Eur Radiol 2023; 33:6557-6568. [PMID: 37014405 PMCID: PMC10415440 DOI: 10.1007/s00330-023-09576-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 03/09/2023] [Accepted: 03/20/2023] [Indexed: 04/05/2023]
Abstract
OBJECTIVE To accurately estimate liver PDFF from chemical shift-encoded (CSE) MRI using a deep learning (DL)-based Multi-Decoder Water-Fat separation Network (MDWF-Net), that operates over complex-valued CSE-MR images with only 3 echoes. METHODS The proposed MDWF-Net and a U-Net model were independently trained using the first 3 echoes of MRI data from 134 subjects, acquired with conventional 6-echoes abdomen protocol at 1.5 T. Resulting models were then evaluated using unseen CSE-MR images obtained from 14 subjects that were acquired with a 3-echoes CSE-MR pulse sequence with a shorter duration compared to the standard protocol. Resulting PDFF maps were qualitatively assessed by two radiologists, and quantitatively assessed at two corresponding liver ROIs, using Bland Altman and regression analysis for mean values, and ANOVA testing for standard deviation (STD) (significance level: .05). A 6-echo graph cut was considered ground truth. RESULTS Assessment of radiologists demonstrated that, unlike U-Net, MDWF-Net had a similar quality to the ground truth, despite it considered half of the information. Regarding PDFF mean values at ROIs, MDWF-Net showed a better agreement with ground truth (regression slope = 0.94, R2 = 0.97) than U-Net (regression slope = 0.86, R2 = 0.93). Moreover, ANOVA post hoc analysis of STDs showed a statistical difference between graph cuts and U-Net (p < .05), unlike MDWF-Net (p = .53). CONCLUSION MDWF-Net showed a liver PDFF accuracy comparable to the reference graph cut method, using only 3 echoes and thus allowing a reduction in the acquisition times. CLINICAL RELEVANCE STATEMENT We have prospectively validated that the use of a multi-decoder convolutional neural network to estimate liver proton density fat fraction allows a significant reduction in MR scan time by reducing the number of echoes required by 50%. KEY POINTS • Novel water-fat separation neural network allows for liver PDFF estimation by using multi-echo MR images with a reduced number of echoes. • Prospective single-center validation demonstrated that echo reduction leads to a significant shortening of the scan time, compared to standard 6-echo acquisition. • Qualitative and quantitative performance of the proposed method showed no significant differences in PDFF estimation with respect to the reference technique.
Collapse
Affiliation(s)
- Juan Pablo Meneses
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
- Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Cristobal Arrieta
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
- Faculty of Engineering, Universidad Alberto Hurtado, Santiago, Chile
| | | | - Cecilia Besa
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
- Department of Radiology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile
| | - Jesús Urbina
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
- Complejo Asistencial Dr. Sótero del Río, Santiago, Chile
| | - Marco Arrese
- Department of Gastroenterology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Juan Cristóbal Gana
- Department of Pediatric Gastroenterology and Nutrition, Division of Pediatrics, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Jose E Galgani
- Department of Health Sciences, Nutrition and Dietetics Career, Faculty of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
- Department of Nutrition, Diabetes and Metabolism, Faculty of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Cristian Tejos
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile
- Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Sergio Uribe
- Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millennium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile.
- Department of Radiology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile.
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Australia.
| |
Collapse
|
7
|
Kufel J, Bargieł-Łączek K, Kocot S, Koźlik M, Bartnikowska W, Janik M, Czogalik Ł, Dudek P, Magiera M, Lis A, Paszkiewicz I, Nawrat Z, Cebula M, Gruszczyńska K. What Is Machine Learning, Artificial Neural Networks and Deep Learning?-Examples of Practical Applications in Medicine. Diagnostics (Basel) 2023; 13:2582. [PMID: 37568945 PMCID: PMC10417718 DOI: 10.3390/diagnostics13152582] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 07/19/2023] [Accepted: 08/01/2023] [Indexed: 08/13/2023] Open
Abstract
Machine learning (ML), artificial neural networks (ANNs), and deep learning (DL) are all topics that fall under the heading of artificial intelligence (AI) and have gained popularity in recent years. ML involves the application of algorithms to automate decision-making processes using models that have not been manually programmed but have been trained on data. ANNs that are a part of ML aim to simulate the structure and function of the human brain. DL, on the other hand, uses multiple layers of interconnected neurons. This enables the processing and analysis of large and complex databases. In medicine, these techniques are being introduced to improve the speed and efficiency of disease diagnosis and treatment. Each of the AI techniques presented in the paper is supported with an example of a possible medical application. Given the rapid development of technology, the use of AI in medicine shows promising results in the context of patient care. It is particularly important to keep a close eye on this issue and conduct further research in order to fully explore the potential of ML, ANNs, and DL, and bring further applications into clinical use in the future.
Collapse
Affiliation(s)
- Jakub Kufel
- Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-808 Zabrze, Poland;
| | - Katarzyna Bargieł-Łączek
- Paediatric Radiology Students’ Scientific Association at the Division of Diagnostic Imaging, Department of Radiology and Nuclear Medicine, Faculty of Medical Science in Katowice, Medical University of Silesia, 40-752 Katowice, Poland; (K.B.-Ł.); (W.B.)
| | - Szymon Kocot
- Bright Coders’ Factory, Technologiczna 2, 45-839 Opole, Poland
| | - Maciej Koźlik
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland;
| | - Wiktoria Bartnikowska
- Paediatric Radiology Students’ Scientific Association at the Division of Diagnostic Imaging, Department of Radiology and Nuclear Medicine, Faculty of Medical Science in Katowice, Medical University of Silesia, 40-752 Katowice, Poland; (K.B.-Ł.); (W.B.)
| | - Michał Janik
- Student Scientific Association Named after Professor Zbigniew Religa at the Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Jordana 19, 41-808 Zabrze, Poland; (M.J.); (Ł.C.); (P.D.); (M.M.); (I.P.)
| | - Łukasz Czogalik
- Student Scientific Association Named after Professor Zbigniew Religa at the Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Jordana 19, 41-808 Zabrze, Poland; (M.J.); (Ł.C.); (P.D.); (M.M.); (I.P.)
| | - Piotr Dudek
- Student Scientific Association Named after Professor Zbigniew Religa at the Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Jordana 19, 41-808 Zabrze, Poland; (M.J.); (Ł.C.); (P.D.); (M.M.); (I.P.)
| | - Mikołaj Magiera
- Student Scientific Association Named after Professor Zbigniew Religa at the Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Jordana 19, 41-808 Zabrze, Poland; (M.J.); (Ł.C.); (P.D.); (M.M.); (I.P.)
| | - Anna Lis
- Cardiology Students’ Scientific Association at the III Department of Cardiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland;
| | - Iga Paszkiewicz
- Student Scientific Association Named after Professor Zbigniew Religa at the Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Jordana 19, 41-808 Zabrze, Poland; (M.J.); (Ł.C.); (P.D.); (M.M.); (I.P.)
| | - Zbigniew Nawrat
- Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, 41-808 Zabrze, Poland;
| | - Maciej Cebula
- Individual Specialist Medical Practice Maciej Cebula, 40-754 Katowice, Poland;
| | - Katarzyna Gruszczyńska
- Department of Radiodiagnostics, Invasive Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, School of Medicine in Katowice, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland;
| |
Collapse
|
8
|
Velikina JV, Zhao R, Buelo CJ, Samsonov AA, Reeder SB, Hernando D. Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping. Magn Reson Med 2023; 90:385-399. [PMID: 36929781 PMCID: PMC11057046 DOI: 10.1002/mrm.29644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 02/24/2023] [Accepted: 03/05/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM. METHODS An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift-encoded imaging. The proposed data-adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi-echo spoiled gradient-recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA-approvedR 2 $$ {R}_2 $$ -based LIC measure andR 2 ∗ $$ {R}_2^{\ast } $$ measurements; repeatability/reproducibility were assessed by Bland-Altman analysis. RESULTS The data-adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with bothR 2 $$ {R}_2 $$ - andR 2 ∗ $$ {R}_2^{\ast } $$ -based measurements were observed for the data-adaptive method (r 2 = 0 . 74 / 0 . 69 $$ {r}^2=0.74/0.69 $$ forR 2 $$ {R}_2 $$ ,0 . 97 / 0 . 95 $$ 0.97/0.95 $$ forR 2 ∗ $$ {R}_2^{\ast } $$ ) than the standard method (r 2 = 0 . 60 / 0 . 66 $$ {r}^2=0.60/0.66 $$ and0 . 79 / 0 . 88 $$ 0.79/0.88 $$ ). For both protocols, the data-adaptive method enabled better test-retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data-adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method. CONCLUSIONS The proposed data-adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.
Collapse
Affiliation(s)
- Julia V Velikina
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Ruiyang Zhao
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Collin J Buelo
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Alexey A Samsonov
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medicine, University of Wisconsin, Madison, WI, USA
- Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA
| | - Diego Hernando
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
9
|
Hamilton JI, Truesdell W, Galizia M, Burris N, Agarwal P, Seiberlich N. A low-rank deep image prior reconstruction for free-breathing ungated spiral functional CMR at 0.55 T and 1.5 T. MAGMA 2023; 36:451-464. [PMID: 37043121 PMCID: PMC11017470 DOI: 10.1007/s10334-023-01088-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 03/02/2023] [Accepted: 04/01/2023] [Indexed: 04/13/2023]
Abstract
OBJECTIVE This study combines a deep image prior with low-rank subspace modeling to enable real-time (free-breathing and ungated) functional cardiac imaging on a commercial 0.55 T scanner. MATERIALS AND METHODS The proposed low-rank deep image prior (LR-DIP) uses two u-nets to generate spatial and temporal basis functions that are combined to yield dynamic images, with no need for additional training data. Simulations and scans in 13 healthy subjects were performed at 0.55 T and 1.5 T using a golden angle spiral bSSFP sequence with images reconstructed using [Formula: see text]-ESPIRiT, low-rank plus sparse (L + S) matrix completion, and LR-DIP. Cartesian breath-held ECG-gated cine images were acquired for reference at 1.5 T. Two cardiothoracic radiologists rated images on a 1-5 scale for various categories, and LV function measurements were compared. RESULTS LR-DIP yielded the lowest errors in simulations, especially at high acceleration factors (R [Formula: see text] 8). LR-DIP ejection fraction measurements agreed with 1.5 T reference values (mean bias - 0.3% at 0.55 T and - 0.2% at 1.5 T). Compared to reference images, LR-DIP images received similar ratings at 1.5 T (all categories above 3.9) and slightly lower at 0.55 T (above 3.4). CONCLUSION Feasibility of real-time functional cardiac imaging using a low-rank deep image prior reconstruction was demonstrated in healthy subjects on a commercial 0.55 T scanner.
Collapse
Affiliation(s)
- Jesse I Hamilton
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | - William Truesdell
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA
| | - Mauricio Galizia
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA
| | - Nicholas Burris
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA
| | - Prachi Agarwal
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, 48109-1590, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
10
|
Dimov AV, Li J, Nguyen TD, Roberts AG, Spincemaille P, Straub S, Zun Z, Prince MR, Wang Y. QSM Throughout the Body. J Magn Reson Imaging 2023; 57:1621-1640. [PMID: 36748806 PMCID: PMC10192074 DOI: 10.1002/jmri.28624] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/19/2023] [Accepted: 01/20/2023] [Indexed: 02/08/2023] Open
Abstract
Magnetic materials in tissue, such as iron, calcium, or collagen, can be studied using quantitative susceptibility mapping (QSM). To date, QSM has been overwhelmingly applied in the brain, but is increasingly utilized outside the brain. QSM relies on the effect of tissue magnetic susceptibility sources on the MR signal phase obtained with gradient echo sequence. However, in the body, the chemical shift of fat present within the region of interest contributes to the MR signal phase as well. Therefore, correcting for the chemical shift effect by means of water-fat separation is essential for body QSM. By employing techniques to compensate for cardiac and respiratory motion artifacts, body QSM has been applied to study liver iron and fibrosis, heart chamber blood and placenta oxygenation, myocardial hemorrhage, atherosclerotic plaque, cartilage, bone, prostate, breast calcification, and kidney stone.
Collapse
Affiliation(s)
- Alexey V. Dimov
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Jiahao Li
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Thanh D. Nguyen
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | | | - Pascal Spincemaille
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Sina Straub
- Department of Radiology, Mayo Clinic, Jacksonville, FL, United States
| | - Zungho Zun
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Martin R. Prince
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Yi Wang
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| |
Collapse
|
11
|
Shih SF, Kafali SG, Calkins KL, Wu HH. Uncertainty-aware physics-driven deep learning network for free-breathing liver fat and R 2 * quantification using self-gated stack-of-radial MRI. Magn Reson Med 2023; 89:1567-1585. [PMID: 36426730 PMCID: PMC9892263 DOI: 10.1002/mrm.29525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 10/02/2022] [Accepted: 10/25/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To develop a deep learning-based method for rapid liver proton-density fat fraction (PDFF) and R2 * quantification with built-in uncertainty estimation using self-gated free-breathing stack-of-radial MRI. METHODS This work developed an uncertainty-aware physics-driven deep learning network (UP-Net) to (1) suppress radial streaking artifacts because of undersampling after self-gating, (2) calculate accurate quantitative maps, and (3) provide pixel-wise uncertainty maps. UP-Net incorporated a phase augmentation strategy, generative adversarial network architecture, and an MRI physics loss term based on a fat-water and R2 * signal model. UP-Net was trained and tested using free-breathing multi-echo stack-of-radial MRI data from 105 subjects. UP-Net uncertainty scores were calibrated in a validation dataset and used to predict quantification errors for liver PDFF and R2 * in a testing dataset. RESULTS Compared with images reconstructed using compressed sensing (CS), UP-Net achieved structural similarity index >0.87 and normalized root mean squared error <0.18. Compared with reference quantitative maps generated using CS and graph-cut (GC) algorithms, UP-Net achieved low mean differences (MD) for liver PDFF (-0.36%) and R2 * (-0.37 s-1 ). Compared with breath-holding Cartesian MRI results, UP-Net achieved low MD for liver PDFF (0.53%) and R2 * (6.75 s-1 ). UP-Net uncertainty scores predicted absolute liver PDFF and R2 * errors with low MD of 0.27% and 0.12 s-1 compared to CS + GC results. The computational time for UP-Net was 79 ms/slice, whereas CS + GC required 3.2 min/slice. CONCLUSION UP-Net rapidly calculates accurate liver PDFF and R2 * maps from self-gated free-breathing stack-of-radial MRI. The pixel-wise uncertainty maps from UP-Net predict quantification errors in the liver.
Collapse
Affiliation(s)
- Shu-Fu Shih
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Sevgi Gokce Kafali
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Kara L. Calkins
- Department of Pediatrics, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H. Wu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| |
Collapse
|
12
|
Jafari R, Do RKG, LaGratta MD, Fung M, Bayram E, Cashen T, Otazo R. GRASPNET: Fast spatiotemporal deep learning reconstruction of golden-angle radial data for free-breathing dynamic contrast-enhanced magnetic resonance imaging. NMR Biomed 2023; 36:e4861. [PMID: 36305619 PMCID: PMC9898111 DOI: 10.1002/nbm.4861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 10/23/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
The purpose of the current study was to develop a deep learning technique called Golden-angle RAdial Sparse Parallel Network (GRASPnet) for fast reconstruction of dynamic contrast-enhanced 4D MRI acquired with golden-angle radial k-space trajectories. GRASPnet operates in the image-time space and does not use explicit data consistency to minimize the reconstruction time. Three different network architectures were developed: (1) GRASPnet-2D: 2D convolutional kernels (x,y) and coil and contrast dimensions collapsed into a single combined dimension; (2) GRASPnet-3D: 3D kernels (x,y,t); and (3) GRASPnet-2D + time: two 3D kernels to first exploit spatial correlations (x,y,1) followed by temporal correlations (1,1,t). The networks were trained using iterative GRASP reconstruction as the reference. Free-breathing 3D abdominal imaging with contrast injection was performed on 33 patients with liver lesions using a T1-weighted golden-angle stack-of-stars pulse sequence. Ten datasets were used for testing. The three GRASPnet architectures were compared with iterative GRASP results using quantitative and qualitative analysis, including impressions from two body radiologists. The three GRASPnet techniques reduced the reconstruction time to about 13 s with similar results with respect to iterative GRASP. Among the GRASPnet techniques, GRASPnet-2D + time compared favorably in the quantitative analysis. Spatiotemporal deep learning enables reconstruction of dynamic 4D contrast-enhanced images in a few seconds, which would facilitate translation to clinical practice of compressed sensing methods that are currently limited by long reconstruction times.
Collapse
Affiliation(s)
- Ramin Jafari
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | | | | | | | | | | | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
13
|
Zhang J, Spincemaille P, Zhang H, Nguyen TD, Li C, Li J, Kovanlikaya I, Sabuncu MR, Wang Y. LARO: Learned acquisition and reconstruction optimization to accelerate quantitative susceptibility mapping. Neuroimage 2023; 268:119886. [PMID: 36669747 PMCID: PMC10021353 DOI: 10.1016/j.neuroimage.2023.119886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/12/2022] [Accepted: 01/16/2023] [Indexed: 01/19/2023] Open
Abstract
Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE) pulse sequence for QSM. Our approach involves optimizing a Cartesian multi-echo k-space sampling pattern with a deep reconstruction network. Next, this optimized sampling pattern was implemented in an mGRE sequence using Cartesian fan-beam k-space segmenting and ordering for prospective scans. Furthermore, we propose to insert a recurrent temporal feature fusion module into the reconstruction network to capture signal redundancies along echo time. Our ablation studies show that both the optimized sampling pattern and proposed reconstruction strategy help improve the quality of the multi-echo image reconstructions. Generalization experiments show that LARO is robust on the test data with new pathologies and different sequence parameters. Our code is available at https://github.com/Jinwei1209/LARO-QSM.git.
Collapse
Affiliation(s)
- Jinwei Zhang
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Pascal Spincemaille
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Hang Zhang
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA
| | - Thanh D Nguyen
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Chao Li
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Applied Physics, Cornell University, Ithaca, NY, USA
| | - Jiahao Li
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Ilhami Kovanlikaya
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA
| | - Mert R Sabuncu
- Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA; Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA
| | - Yi Wang
- Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Department of Radiology, Weill Medical College of Cornell University, New York, NY, USA.
| |
Collapse
|
14
|
Basty N, Thanaj M, Cule M, Sorokin EP, Liu Y, Thomas EL, Bell JD, Whitcher B. Artifact-free fat-water separation in Dixon MRI using deep learning. J Big Data 2023; 10:4. [PMID: 36686622 PMCID: PMC9835035 DOI: 10.1186/s40537-022-00677-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 12/25/2022] [Indexed: 06/17/2023]
Abstract
Chemical-shift encoded MRI (CSE-MRI) is a widely used technique for the study of body composition and metabolic disorders, where derived fat and water signals enable the quantification of adipose tissue and muscle. The UK Biobank is acquiring whole-body Dixon MRI (a specific implementation of CSE-MRI) for over 100,000 participants. Current processing methods associated with large whole-body volumes are time intensive and prone to artifacts during fat-water separation performed by the scanner, making quantitative analysis challenging. The most common artifacts are fat-water swaps, where the labels are inverted at the voxel level. It is common for researchers to discard swapped data (generally around 10%), which is wasteful and may lead to unintended biases. Given the large number of whole-body Dixon MRI acquisitions in the UK Biobank, thousands of swaps are expected to be present in the fat and water volumes from image reconstruction performed on the scanner. If they go undetected, errors will propagate into processes such as organ segmentation, and dilute the results in population-based analyses. There is a clear need for a robust method to accurately separate fat and water volumes in big data collections like the UK Biobank. We formulate fat-water separation as a style transfer problem, where swap-free fat and water volumes are predicted from the acquired Dixon MRI data using a conditional generative adversarial network, and introduce a new loss function for the generator model. Our method is able to predict highly accurate fat and water volumes free from artifacts in the UK Biobank. We show that our model separates fat and water volumes using either single input (in-phase only) or dual input (in-phase and opposed-phase) data, with the latter producing superior results. Our proposed method enables faster and more accurate downstream analysis of body composition from Dixon MRI in population studies by eliminating the need for visual inspection or discarding data due to fat-water swaps. Supplementary Information The online version contains supplementary material available at 10.1186/s40537-022-00677-1.
Collapse
Affiliation(s)
- Nicolas Basty
- Research Centre for Optimal Health, University of Westminster, London, UK
| | - Marjola Thanaj
- Research Centre for Optimal Health, University of Westminster, London, UK
| | | | | | - Yi Liu
- Calico Life Sciences LLC, South San Francisco, USA
| | - E. Louise Thomas
- Research Centre for Optimal Health, University of Westminster, London, UK
| | - Jimmy D. Bell
- Research Centre for Optimal Health, University of Westminster, London, UK
| | - Brandon Whitcher
- Research Centre for Optimal Health, University of Westminster, London, UK
| |
Collapse
|
15
|
Hanspach J, Bollmann S, Grigo J, Karius A, Uder M, Laun FB. Deep learning-based quantitative susceptibility mapping (QSM) in the presence of fat using synthetically generated multi-echo phase training data. Magn Reson Med 2022; 88:1548-1560. [PMID: 35713187 DOI: 10.1002/mrm.29265] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 02/14/2022] [Accepted: 03/22/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE To enable a fast and automatic deep learning-based QSM reconstruction of tissues with diverse chemical shifts, relevant to most regions outside the brain. METHODS A UNET was trained to reconstruct susceptibility maps using synthetically generated, unwrapped, multi-echo phase data as input. The RMS error with respect to synthetic validation data was computed. The method was tested on two in vivo knee and two pelvis data sets. Comparisons were made to a conventional fat-water separation pipeline by applying a commonly used graph-cut algorithm, both without and with an extended mask for background field removal (FWS-CONV-QSM and FWS-MASK-CONV-QSM, respectively). Several regions of interest were segmented and compared. Furthermore, the approach was tested on a prostate cancer patient receiving low-dose-rate brachytherapy, to detect and localize the seeds by MRI. RESULTS The RMS error was 0.292 ppm with FWS-CONV-QSM and 0.123 ppm for the UNET approach. Susceptibility maps were reconstructed much faster (< 10 s) and completely automatically (no background masking needed) by the UNET compared with the other applied techniques (5 min 51 s and 22 min 44 s for CONV-QSM and FWS-MASK-CONV-QSM, respectively. Background artifacts, fat-water swaps, and hypointense artifacts between I-125 seeds of a patient receiving low-dose brachytherapy in the prostate were largely reduced in the UNET approach. CONCLUSIONS Deep learning-based QSM reconstruction, trained solely with synthetic data, is well-suited to rapidly reconstructing high-quality susceptibility maps in the presence of fat without needing masking for background field removal.
Collapse
Affiliation(s)
- Jannis Hanspach
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Steffen Bollmann
- School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, Australia
| | - Johanna Grigo
- Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Andre Karius
- Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Frederik B Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
16
|
Chen X, Wang W, Huang J, Wu J, Chen L, Cai C, Cai S, Chen Z. Ultrafast water–fat separation using deep learning–based single‐shot MRI. Magn Reson Med 2022; 87:2811-2825. [DOI: 10.1002/mrm.29172] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 12/13/2021] [Accepted: 01/07/2022] [Indexed: 12/16/2022]
Affiliation(s)
- Xinran Chen
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Wei Wang
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Jianpan Huang
- Department of Biomedical Engineering City University of Hong Kong Hong Kong People’s Republic of China
| | - Jian Wu
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Lin Chen
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Congbo Cai
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Shuhui Cai
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| | - Zhong Chen
- Department of Electronic Science Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance School of Electronic Science and Engineering National Model Microelectronics College Xiamen University Xiamen Fujian People’s Republic of China
| |
Collapse
|
17
|
Kim J, Nguyen TD, Zhang J, Gauthier SA, Marcille M, Zhang H, Cho J, Spincemaille P, Wang Y. Subsecond accurate myelin water fraction reconstruction from FAST-T 2 data with 3D UNET. Magn Reson Med 2022; 87:2979-2988. [PMID: 35092094 DOI: 10.1002/mrm.29176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 12/31/2021] [Accepted: 01/08/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE To develop a 3D UNET convolutional neural network for rapid extraction of myelin water fraction (MWF) maps from six-echo fast acquisition with spiral trajectory and T2 -prep data and to evaluate its accuracy in comparison with multilayer perceptron (MLP) network. METHODS The MWF maps were extracted from 138 patients with multiple sclerosis using an iterative three-pool nonlinear least-squares algorithm (NLLS) without and with spatial regularization (srNLLS), which were used as ground-truth labels to train, validate, and test UNET and MLP networks as a means to accelerate data fitting. Network testing was performed in 63 patients with multiple sclerosis and a numerically simulated brain phantom at SNR of 200, 100 and 50. RESULTS Simulations showed that UNET reduced the MWF mean absolute error by 30.1% to 56.4% and 16.8% to 53.6% over the whole brain and by 41.2% to 54.4% and 21.4% to 49.4% over the lesions for predicting srNLLS and NLLS MWF, respectively, compared to MLP, with better performance at lower SNRs. UNET also outperformed MLP for predicting srNLLS MWF in the in vivo multiple-sclerosis brain data, reducing mean absolute error over the whole brain by 61.9% and over the lesions by 67.5%. However, MLP yielded 41.1% and 51.7% lower mean absolute error for predicting in vivo NLLS MWF over the whole brain and the lesions, respectively, compared with UNET. The whole-brain MWF processing time using a GPU was 0.64 seconds for UNET and 0.74 seconds for MLP. CONCLUSION Subsecond whole-brain MWF extraction from fast acquisition with spiral trajectory and T2 -prep data using UNET is feasible and provides better accuracy than MLP for predicting MWF output of srNLLS algorithm.
Collapse
Affiliation(s)
- Jeremy Kim
- Department of Computer Science, Stanford University, Stanford, California, USA
| | - Thanh D Nguyen
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Jinwei Zhang
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.,Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Susan A Gauthier
- Department of Neurology, Weill Cornell Medicine, New York, New York, USA
| | - Melanie Marcille
- Department of Neurology, Weill Cornell Medicine, New York, New York, USA
| | - Hang Zhang
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Junghun Cho
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | | | - Yi Wang
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.,Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| |
Collapse
|
18
|
Xu Y, Lou J, Gao Z, Zhan M. Computed Tomography Image Features under Deep Learning Algorithm Applied in Staging Diagnosis of Bladder Cancer and Detection on Ceramide Glycosylation. Comput Math Methods Med 2022; 2022:7979523. [PMID: 35035524 PMCID: PMC8759889 DOI: 10.1155/2022/7979523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/01/2021] [Accepted: 11/10/2021] [Indexed: 11/18/2022]
Abstract
The research is aimed at investigating computed tomography (CT) image based on deep learning algorithm and the application value of ceramide glycosylation in diagnosing bladder cancer. The images of ordinary CT detection were improved. In this study, 60 bladder cancer patients were selected and performed with ordinary CT detection, and the detection results were processed by CT based on deep learning algorithms and compared with pathological diagnosis. In addition, Western Blot technology was used to detect the expression of glucose ceramide synthase (GCS) in the cell membrane of tumor tissues and normal tissues of bladder. The comparison results found that, in simple CT clinical staging, the coincidence rates of T1 stage, T2a stage, T2b stage, T3 stage, and T4 stage were 28.56%, 62.51%, 78.94%, 84.61%, and 74.99%, respectively; and the total coincidence rate of CT clinical staging was 63.32%, which was greatly different from the clinical staging of pathological diagnosis (P < 0.05). In the clinical staging of algorithm-based CT test results, the coincidence rates of T1 stage and T2a stage were 50.01% and 91.65%, respectively; and those of T2b stage, T3 stage, and T4 stage were 100.00%; and the total coincidence rate was 96.69%, which was not obviously different from the clinical staging of pathological diagnosis (P > 0.05). Therefore, it could be concluded that the algorithm-based CT detection results were more accurate, and the use of CT scans based on deep learning algorithms in the preoperative staging and clinical treatment of bladder cancer showed reliable guiding significance and clinical value. In addition, it was found that the expression level of GCS in normal bladder tissues was much lower than that in bladder cancer tissues. This indicated that the changes in GCS were closely related to the development and prognosis of bladder cancer. Therefore, it was believed that GCS may be an effective target for the treatment of bladder cancer in the future, and further research was needed for specific conditions.
Collapse
Affiliation(s)
- Yisheng Xu
- Department of Radiology, Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou 311201, China
| | - Jianghua Lou
- Department of Radiology, Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou 311201, China
| | - Zhiqin Gao
- Department of Radiology, Hangzhou Xiaoshan Hospital of Traditional Chinese Medicine, Hangzhou 311201, China
| | - Ming Zhan
- Department of Radiology, Affiliated Xiaoshan Hospital, Hangzhou Normal University, Hangzhou 311201, China
| |
Collapse
|
19
|
Liu Y, Niu H, Ren P, Ren J, Wei X, Liu W, Ding H, Li J, Xia J, Zhang T, Lv H, Yin H, Wang Z. Generation of quantification maps and weighted images from synthetic magnetic resonance imaging using deep learning network. Phys Med Biol 2021; 67. [PMID: 34965516 DOI: 10.1088/1361-6560/ac46dd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 12/29/2021] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The generation of quantification maps and weighted images in synthetic MRI techniques is based on complex fitting equations. This process requires longer image generation times. The objective of this study is to evaluate the feasibility of deep learning method for fast reconstruction of synthetic MRI. APPROACH A total of 44 healthy subjects were recruited and random divided into a training set (30 subjects) and a testing set (14 subjects). A multiple-dynamic, multiple-echo (MDME) sequence was used to acquire synthetic MRI images. Quantification maps (T1, T2, and proton density (PD) maps) and weighted (T1W, T2W, and T2W FLAIR) images were created with MAGiC software and then used as the ground truth images in the deep learning (DL) model. An improved multichannel U-Net structure network was trained to generate quantification maps and weighted images from raw synthetic MRI imaging data (8 module images). Quantitative evaluation was performed on quantification maps. Quantitative evaluation metrics, as well as qualitative evaluation were used in weighted image evaluation. Nonparametric Wilcoxon signed-rank tests were performed in this study. MAIN RESULTS The results of quantitative evaluation show that the error between the generated quantification images and the reference images is small. For weighted images, no significant difference in overall image quality or SNR was identified between DL images and synthetic images. Notably, the DL images achieved improved image contrast with T2W images, and fewer artifacts were present on DL images than synthetic images acquired by T2W FLAIR. SIGNIFICANCE The DL algorithm provides a promising method for image generation in synthetic MRI techniques, in which every step of the calculation can be optimized and faster, thereby simplifying the workflow of synthetic MRI techniques.
Collapse
Affiliation(s)
- Yawen Liu
- School of Biological Science and Medical Engineering, Beihang University, Xueyuan Road 100 hectares, Beijing, 100191, CHINA
| | - Haijun Niu
- School of Biological Science and Medical Engineering, Beihang University, Xueyuan Road 100 hectares, Beijing, 100191, CHINA
| | - Pengling Ren
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, 100050, CHINA
| | - Jialiang Ren
- GE Healthcare Beijing, ., Beijing, 100176, CHINA
| | - Xuan Wei
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Wenjuan Liu
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Heyu Ding
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Jing Li
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | | | - Tingting Zhang
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Han Lv
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Hongxia Yin
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| | - Zhenchang Wang
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, Yong'an Road 36, Beijing, Beijing, 100050, CHINA
| |
Collapse
|
20
|
Cho J, Zhang J, Spincemaille P, Zhang H, Hubertus S, Wen Y, Jafari R, Zhang S, Nguyen TD, Dimov AV, Gupta A, Wang Y. QQ-NET - using deep learning to solve quantitative susceptibility mapping and quantitative blood oxygen level dependent magnitude (QSM+qBOLD or QQ) based oxygen extraction fraction (OEF) mapping. Magn Reson Med 2021; 87:1583-1594. [PMID: 34719059 DOI: 10.1002/mrm.29057] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 09/01/2021] [Accepted: 10/07/2021] [Indexed: 01/17/2023]
Abstract
PURPOSE To improve accuracy and speed of quantitative susceptibility mapping plus quantitative blood oxygen level-dependent magnitude (QSM+qBOLD or QQ) -based oxygen extraction fraction (OEF) mapping using a deep neural network (QQ-NET). METHODS The 3D multi-echo gradient echo images were acquired in 34 ischemic stroke patients and 4 healthy subjects. Arterial spin labeling and diffusion weighted imaging (DWI) were also performed in the patients. NET was developed to solve the QQ model inversion problem based on Unet. QQ-based OEF maps were reconstructed with previously introduced temporal clustering, tissue composition, and total variation (CCTV) and NET. The results were compared in simulation, ischemic stroke patients, and healthy subjects using a two-sample Kolmogorov-Smirnov test. RESULTS In the simulation, QQ-NET provided more accurate and precise OEF maps than QQ-CCTV with 150 times faster reconstruction speed. In the subacute stroke patients, OEF from QQ-NET had greater contrast-to-noise ratio (CNR) between DWI-defined lesions and their unaffected contralateral normal tissue than with QQ-CCTV: 1.9 ± 1.3 vs 6.6 ± 10.7 (p = 0.03). In healthy subjects, both QQ-CCTV and QQ-NET provided uniform OEF maps. CONCLUSION QQ-NET improves the accuracy of QQ-based OEF with faster reconstruction.
Collapse
Affiliation(s)
- Junghun Cho
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Jinwei Zhang
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Pascal Spincemaille
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Hang Zhang
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Simon Hubertus
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Yan Wen
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Ramin Jafari
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Shun Zhang
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Thanh D Nguyen
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Alexey V Dimov
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Ajay Gupta
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Yi Wang
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA.,Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| |
Collapse
|
21
|
Weber KA, Abbott R, Bojilov V, Smith AC, Wasielewski M, Hastie TJ, Parrish TB, Mackey S, Elliott JM. Multi-muscle deep learning segmentation to automate the quantification of muscle fat infiltration in cervical spine conditions. Sci Rep 2021; 11:16567. [PMID: 34400672 PMCID: PMC8368246 DOI: 10.1038/s41598-021-95972-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 07/28/2021] [Indexed: 12/23/2022] Open
Abstract
Muscle fat infiltration (MFI) has been widely reported across cervical spine disorders. The quantification of MFI requires time-consuming and rater-dependent manual segmentation techniques. A convolutional neural network (CNN) model was trained to segment seven cervical spine muscle groups (left and right muscles segmented separately, 14 muscles total) from Dixon MRI scans (n = 17, 17 scans < 2 weeks post motor vehicle collision (MVC), and 17 scans 12 months post MVC). The CNN MFI measures demonstrated high test reliability and accuracy in an independent testing dataset (n = 18, 9 scans < 2 weeks post MVC, and 9 scans 12 months post MVC). Using the CNN in 84 participants with scans < 2 weeks post MVC (61 females, 23 males, age = 34.2 ± 10.7 years) differences in MFI between the muscle groups and relationships between MFI and sex, age, and body mass index (BMI) were explored. Averaging across all muscles, females had significantly higher MFI than males (p = 0.026). The deep cervical muscles demonstrated significantly greater MFI than the more superficial muscles (p < 0.001), and only MFI within the deep cervical muscles was moderately correlated to age (r > 0.300, p ≤ 0.001). CNN's allow for the accurate and rapid, quantitative assessment of the composition of the architecturally complex muscles traversing the cervical spine. Acknowledging the wider reports of MFI in cervical spine disorders and the time required to manually segment the individual muscles, this CNN may have diagnostic, prognostic, and predictive value in disorders of the cervical spine.
Collapse
Affiliation(s)
- Kenneth A Weber
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Palo Alto, CA, USA.
| | - Rebecca Abbott
- Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Vivie Bojilov
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Palo Alto, CA, USA
| | - Andrew C Smith
- Physical Therapy Program, Department of Physical Medicine and Rehabilitation, School of Medicine, University of Colorado, Aurora, CO, USA
| | - Marie Wasielewski
- Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Trevor J Hastie
- Statistics Department, Stanford University, Palo Alto, CA, USA
| | - Todd B Parrish
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Sean Mackey
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Palo Alto, CA, USA
| | - James M Elliott
- Northern Sydney Local Health District, The Kolling Institute, St. Leonards, NSW, Australia.,The Faculty of Medicine and Health, The University of Sydney, Camperdown, NSW, Australia.,Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| |
Collapse
|