1
|
Akai H, Yasaka K, Sugawara H, Furuta T, Tajima T, Kato S, Yamaguchi H, Ohtomo K, Abe O, Kiryu S. Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study. Clin Radiol 2024; 79:453-459. [PMID: 38614869 DOI: 10.1016/j.crad.2024.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 12/29/2023] [Accepted: 03/02/2024] [Indexed: 04/15/2024]
Abstract
AIM To evaluate whether deep learning reconstruction (DLR) can accelerate the acquisition of magnetic resonance imaging (MRI) sequences of the knee for clinical use. MATERIALS AND METHODS Using a 1.5-T MRI scanner, sagittal fat-suppressed T2-weighted imaging (fs-T2WI), coronal proton density-weighted imaging (PDWI), and coronal T1-weighted imaging (T1WI) were performed. DLR was applied to images with a number of signal averages (NSA) of 1 to obtain 1DLR images. Then 1NSA, 1DLR, and 4NSA images were compared subjectively, and by noise (standard deviation of intra-articular water or medial meniscus) and contrast-to-noise ratio between two anatomical structures or between an anatomical structure and intra-articular water. RESULTS Twenty-seven healthy volunteers (age: 40.6 ± 11.9 years) were enrolled. Three 1DLR image sequences were obtained within 200 s (approximately 12 minutes for 4NSA image). According to objective evaluations, PDWI 1DLR images showed the smallest noise and significantly higher contrast than 1NSA and 4NSA images. For fs-T2WI, smaller noise and higher contrast were observed in the order of 4NSA, 1DLR, and 1NSA images. According to the subjective analysis, structure visibility, image noise, and overall image quality were significantly better for PDWI 1DLR than 1NSA images; moreover, the visibility of the meniscus and bone, image noise, and overall image quality were significantly better for 1DLR than 4NSA images. Fs-T2WI and T1WI 1DLR images showed no difference between 1DLR and 4NSA images. CONCLUSION Compared to PDWI 4NSA images, PDWI 1DLR images were of higher quality, while the quality of fs-T2WI and T1WI 1DLR images was similar to that of 4NSA images.
Collapse
Affiliation(s)
- H Akai
- Department of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan; Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan
| | - K Yasaka
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan; Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - H Sugawara
- Department of Diagnostic Radiology, McGill University, 1650 Cedar Avenue, Montreal, Quebec, H3G 1A4, Canada
| | - T Furuta
- Department of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - T Tajima
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan; Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo, 108-8329, Japan
| | - S Kato
- Department of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - H Yamaguchi
- Department of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639, Japan
| | - K Ohtomo
- International University of Health and Welfare, 2600-1 Kiakanemaru, Ohtawara, Tochigi, 324-8501, Japan
| | - O Abe
- Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - S Kiryu
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba, 286-0124, Japan.
| |
Collapse
|
2
|
Zhang Y, Cao J, Qiao C, Gao B, Du W, Lin L, Liu N, Song Q, Miao Y. Fast imaging of lenticulostriate arteries by high-resolution black-blood T1-weighted imaging with variable flip angles and acceleration by compressed sensitivity encoding. Magn Reson Imaging 2024; 110:51-56. [PMID: 38458551 DOI: 10.1016/j.mri.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 02/24/2024] [Accepted: 03/04/2024] [Indexed: 03/10/2024]
Abstract
OBJECTIVE We investigated the feasibility of using compressed sensitivity encoding (CS-SENSE) to accelerate high-resolution black-blood T1-weighted imaging with variable flip angles (T1WI-VFA) for efficient visualization and characterization of lenticulostriate arteries (LSAs) on a 3.0 T MR scanner. MATERIALS AND METHODS Twenty-five healthy volunteers and 18 patients with the cerebrovascular disease were prospectively enrolled. Healthy volunteers underwent T1WI-VFA sequences with different acceleration factors (AFs), including conventional sensitivity encoding (SENSE) AF = 3 and CS-SENSE AF = 3, 4, 5, and 6 (SENSE3, CS3, CS4, CS5, CS6, respectively) at 3 Tesla MRI scanner. Objective evaluation (contrast ratio and number, length, and branches of LSAs) and subjective evaluation (overall image quality and LSA visualization scores) were used to assess image quality and LSA visualization. Comparisons were performed among the 5 sequences to select the best AF. All patients underwent both T1WI-VFA with the optimal AF and digital subtraction angiography (DSA) examination, and the number of LSAs observed by T1WI-VFA was compared with that by DSA. RESULTS Pair-wise comparisons among CS3, CS4, and SENSE3 revealed no significant differences in both objective measurements and subjective evaluation (all P > 0.05). In patients, there was no significant difference in LSA counts on the same side between T1WI-VFA with CS4 and DSA (3, 3-4 and 3, 3-3, P = 0.243). CONCLUSIONS CS3 provided better LSA visualization but a longer scan duration compared to CS4. And, CS4 strikes a good balance between LSA visualization and acquisition time, which is recommended for routine clinical use.
Collapse
Affiliation(s)
- Yukun Zhang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Jiajun Cao
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Chen Qiao
- Department of Intervention, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Bingbing Gao
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Wei Du
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Liangjie Lin
- Clinical and Technical Support, Philips Healthcare, Beijing 100000, China
| | - Na Liu
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Qingwei Song
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
| | - Yanwei Miao
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China.
| |
Collapse
|
3
|
Herrmann J, Gassenmaier S, Keller G, Koerzdoerfer G, Almansour H, Nickel D, Othman A, Afat S, Werner S. Deep Learning MRI Reconstruction for Accelerating Turbo Spin Echo Hand and Wrist Imaging: A Comparison of Image Quality, Visualization of Anatomy, and Detection of Common Pathologies with Standard Imaging. Acad Radiol 2023; 30:2606-2615. [PMID: 36797172 DOI: 10.1016/j.acra.2022.12.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/20/2022] [Accepted: 12/26/2022] [Indexed: 02/16/2023]
Abstract
RATIONALE AND OBJECTIVES Magnetic resonance imaging (MRI) of the hand and wrist is a routine MRI examination and takes about 15-20 minutes, which can lead to problems resulting from the relatively long scan time, such as decreased image quality due to motion artifacts and lower patient throughput. The objective of this study was to evaluate a deep learning (DL) reconstruction for turbo spin echo (TSE) sequences of the hand and wrist regarding image quality, visualization of anatomy, and diagnostic performance concerning common pathologies. MATERIALS AND METHODS Twenty-one patients (mean age: 43 ± 19 [19-85] years, 10 men, 11 female) were prospectively enrolled in this study between October 2020 and June 2021. Each participant underwent two MRI protocols: first, standard fully sampled TSE sequences reconstructed with a standard GRAPPA reconstruction (TSES) and second, prospectively undersampled TSE sequences using a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Both protocols were acquired consecutively in one examination. Two experienced MSK-imaging radiologists qualitatively evaluated the images concerning image quality, noise, edge sharpness, artifacts, and diagnostic confidence, as well as the delineation of anatomical structures (triangular fibrocartilage complex, tendon of the extensor carpi ulnaris muscle, extrinsic and intrinsic ligaments, median nerve, cartilage) using a five-point Likert scale and assessed common pathologies. Wilcoxon signed-rank test and kappa statistics were performed to compare the sequences. RESULTS Overall image quality, artifacts, delineation of anatomical structures, and diagnostic confidence of TSEDL were rated to be comparable to TSES (p > 0.05). Additionally, TSEDL showed decreased image noise (4.90, median 5, IQR 5-5) compared to TSES (4.52, median 5, IQR 4-5, p < 0.05) and improved edge sharpness (TSEDL: 4.10, median 4, IQR 3.5-5; TSES: 3.57, median 4, IQR 3-4; p < 0.05). Inter- and intrareader agreement was substantial to almost perfect (κ = 0.632-1.000) for the detection of common pathologies. Time of acquisition could be reduced by more than 60% with the protocol using TSEDL. CONCLUSION Compared to TSES, TSEDL provided decreased noise and increased edge sharpness, equal image quality, delineation of anatomical structures, detection of pathologies, and diagnostic confidence. Therefore, TSEDL may be clinically relevant for hand and wrist imaging, as it reduces examination time by more than 60%, thus increasing patient comfort and patient throughput.
Collapse
Affiliation(s)
- Judith Herrmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Gabriel Keller
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | | | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| | - Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Ahmed Othman
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany; Department of Neuroradiology, University Medical Center Mainz, Mainz, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany.
| | - Sebastian Werner
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Tuebingen, Germany
| |
Collapse
|
4
|
Dratsch T, Siedek F, Zäske C, Sonnabend K, Rauen P, Terzis R, Hahnfeldt R, Maintz D, Persigehl T, Bratke G, Iuga A. Reconstruction of shoulder MRI using deep learning and compressed sensing: a validation study on healthy volunteers. Eur Radiol Exp 2023; 7:66. [PMID: 37880546 PMCID: PMC10600091 DOI: 10.1186/s41747-023-00377-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 08/10/2023] [Indexed: 10/27/2023] Open
Abstract
BACKGROUND To investigate the potential of combining compressed sensing (CS) and deep learning (DL) for accelerated two-dimensional (2D) and three-dimensional (3D) magnetic resonance imaging (MRI) of the shoulder. METHODS Twenty healthy volunteers were examined using at 3-T scanner with a fat-saturated, coronal, 2D proton density-weighted sequence with four acceleration levels (2.3, 4, 6, and 8) and a 3D sequence with three acceleration levels (8, 10, and 13), all accelerated with CS and reconstructed using the conventional algorithm and a new DL-based algorithm (CS-AI). Subjective image quality was evaluated by two blinded readers using 6 criteria on a 5-point Likert scale (overall impression, artifacts, and delineation of the subscapularis tendon, bone, acromioclavicular joint, and glenoid labrum). Objective image quality was measured by calculating signal-to-noise-ratio, contrast-to-noise-ratio, and a structural similarity index measure. All reconstructions were compared to the clinical standard (CS 2D acceleration factor 2.3; CS 3D acceleration factor 8). Additionally, subjective and objective image quality were compared between CS and CS-AI with the same acceleration levels. RESULTS Both 2D and 3D sequences reconstructed with CS-AI achieved on average significantly better subjective and objective image quality compared to sequences reconstructed with CS with the same acceleration factor (p ≤ 0.011). Comparing CS-AI to the reference sequences showed that 4-fold acceleration for 2D sequences and 13-fold acceleration for 3D sequences without significant loss of quality (p ≥ 0.058). CONCLUSIONS For MRI of the shoulder at 3 T, a DL-based algorithm allowed additional acceleration of acquisition times compared to the conventional approach. RELEVANCE STATEMENT The combination of deep-learning and compressed sensing hold the potential for further scan time reduction in 2D and 3D imaging of the shoulder while providing overall better objective and subjective image quality compared to the conventional approach. TRIAL REGISTRATION DRKS00024156. KEY POINTS • Combination of compressed sensing and deep learning improved image quality and allows for significant acceleration of shoulder MRI. • Deep learning-based algorithm achieved better subjective and objective image quality than conventional compressed sensing. • For shoulder MRI at 3 T, 40% faster image acquisition for 2D sequences and 38% faster image acquisition for 3D sequences may be possible.
Collapse
Affiliation(s)
- Thomas Dratsch
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
| | - Florian Siedek
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Charlotte Zäske
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Kristina Sonnabend
- Philips GmbH Market DACH, Hamburg, Röntgenstrasse 22, 22335, Hamburg, Germany
| | - Philip Rauen
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Robert Terzis
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Robert Hahnfeldt
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - David Maintz
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Thorsten Persigehl
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Grischa Bratke
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Andra Iuga
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
5
|
Zhao Q, Xu J, Yang YX, Yu D, Zhao Y, Wang Q, Yuan H. AI-assisted accelerated MRI of the ankle: clinical practice assessment. Eur Radiol Exp 2023; 7:62. [PMID: 37857868 PMCID: PMC10587051 DOI: 10.1186/s41747-023-00374-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 08/04/2023] [Indexed: 10/21/2023] Open
Abstract
BACKGROUND High-spatial resolution magnetic resonance imaging (MRI) is essential for imaging ankle joints. However, the clinical application of fast spin-echo sequences remains limited by their lengthy acquisition time. Artificial intelligence-assisted compressed sensing (ACS) technology has been recently introduced as an integrative acceleration solution. We compared ACS-accelerated 3-T ankle MRI to conventional methods of compressed sensing (CS) and parallel imaging (PI) . METHODS We prospectively included 2 healthy volunteers and 105 patients with ankle pain. ACS acceleration factors for ankle protocol of T1-, T2-, and proton density (PD)-weighted sequences were optimized in a pilot study on healthy volunteers (acceleration factor 3.2-3.3×). Images of patients acquired using ACS and conventional acceleration methods were compared in terms of acquisition times, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and diagnostic agreement. Shapiro-Wilk test, Cohen κ, intraclass correlation coefficient, and one-way ANOVA with post hoc tests (Tukey or Dunn) were used. RESULTS ACS acceleration reduced the acquisition times of T1-, T2-, and PD-weighted sequences by 32-43%, compared with conventional CS and PI, while maintaining image quality (mostly higher SNR with p < 0.004 and higher CNR with p < 0.047). The diagnostic agreement between ACS and conventional sequences was rated excellent (κ = 1.00). CONCLUSIONS The optimum ACS acceleration factors for ankle MRI were found to be 3.2-3.3× protocol. The ACS allows faster imaging, yielding similar image quality and diagnostic performance. RELEVANCE STATEMENT AI-assisted compressed sensing significantly accelerates ankle MRI times while preserving image quality and diagnostic precision, potentially expediting patient diagnoses and improving clinical workflows. KEY POINTS • AI-assisted compressed sensing (ACS) significantly reduced scan duration for ankle MRI. • Similar image quality achieved by ACS compared to conventional acceleration methods. • A high agreement by three acceleration methods in the diagnosis of ankle lesions was observed.
Collapse
Affiliation(s)
- Qiang Zhao
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Jiajia Xu
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Yu Xin Yang
- United Imaging Research Institute of Intelligent Imaging, Beijing, People's Republic of China
| | - Dan Yu
- United Imaging Research Institute of Intelligent Imaging, Beijing, People's Republic of China
| | - Yuqing Zhao
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Qizheng Wang
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.
| |
Collapse
|
6
|
Herrmann J, Afat S, Gassenmaier S, Koerzdoerfer G, Lingg A, Almansour H, Nickel D, Werner S. Image Quality and Diagnostic Performance of Accelerated 2D Hip MRI with Deep Learning Reconstruction Based on a Deep Iterative Hierarchical Network. Diagnostics (Basel) 2023; 13:3241. [PMID: 37892062 PMCID: PMC10606422 DOI: 10.3390/diagnostics13203241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/10/2023] [Accepted: 10/14/2023] [Indexed: 10/29/2023] Open
Abstract
OBJECTIVES Hip MRI using standard multiplanar sequences requires long scan times. Accelerating MRI is accompanied by reduced image quality. This study aimed to compare standard two-dimensional (2D) turbo spin echo (TSE) sequences with accelerated 2D TSE sequences with deep learning (DL) reconstruction (TSEDL) for routine clinical hip MRI at 1.5 and 3 T in terms of feasibility, image quality, and diagnostic performance. MATERIAL AND METHODS In this prospective, monocentric study, TSEDL was implemented clinically and evaluated in 14 prospectively enrolled patients undergoing a clinically indicated hip MRI at 1.5 and 3T between October 2020 and May 2021. Each patient underwent two examinations: For the first exam, we used standard sequences with generalized autocalibrating partial parallel acquisition reconstruction (TSES). For the second exam, we implemented prospectively undersampled TSE sequences with DL reconstruction (TSEDL). Two radiologists assessed the TSEDL and TSES regarding image quality, artifacts, noise, edge sharpness, diagnostic confidence, and delineation of anatomical structures using an ordinal five-point Likert scale (1 = non-diagnostic; 2 = poor; 3 = moderate; 4 = good; 5 = excellent). Both sequences were compared regarding the detection of common pathologies of the hip. Comparative analyses were conducted to assess the differences between TSEDL and TSES. RESULTS Compared with TSES, TSEDL was rated to be significantly superior in terms of image quality (p ≤ 0.020) with significantly reduced noise (p ≤ 0.001) and significantly improved edge sharpness (p = 0.003). No difference was found between TSES and TSEDL concerning the extent of artifacts, diagnostic confidence, or the delineation of anatomical structures (p > 0.05). Example acquisition time reductions for the TSE sequences of 52% at 3 Tesla and 70% at 1.5 Tesla were achieved. CONCLUSION TSEDL of the hip is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared with TSES, reducing the acquisition time significantly.
Collapse
Affiliation(s)
- Judith Herrmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Gregor Koerzdoerfer
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| | - Andreas Lingg
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Dominik Nickel
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany
| | - Sebastian Werner
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| |
Collapse
|
7
|
Roemer FW, Hochberg MC, Carrino JA, Kompel AJ, Diaz L, Hayashi D, Crema MD, Guermazi A. Role of imaging for eligibility and safety of a-NGF clinical trials. Ther Adv Musculoskelet Dis 2023; 15:1759720X231171768. [PMID: 37284331 PMCID: PMC10240557 DOI: 10.1177/1759720x231171768] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 04/05/2023] [Indexed: 06/08/2023] Open
Abstract
Nerve growth factor (a-NGF) inhibitors have been developed for pain treatment including symptomatic osteoarthritis (OA) and have proven analgesic efficacy and improvement in functional outcomes in patients with OA. However, despite initial promising data, a-NGF clinical trials focusing on OA treatment had been suspended in 2010. Reasons were based on concerns regarding accelerated OA progression but were resumed in 2015 including detailed safety mitigation based on imaging. In 2021, an FDA advisory committee voted against approving tanezumab (one of the a-NGF compounds being evaluated) and declared that the risk evaluation and mitigation strategy was not sufficient to mitigate potential safety risks. Future clinical trials evaluating the efficacy of a-NGF or comparable molecules will need to define strict eligibility criteria and will have to include strategies to monitor safety closely. While disease-modifying effects are not the focus of a-NGF treatments, imaging plays an important role to evaluate eligibility of potential participants and to monitor safety during the course of these studies. Aim is to identify subjects with on-going safety findings at the time of inclusion, define those potential participants that are at increased risk for accelerated OA progression and to withdraw subjects from on-going studies in a timely fashion that exhibit imaging-confirmed structural safety events such as rapid progressive OA. OA efficacy- and a-NGF studies apply imaging for different purposes. In OA efficacy trials image acquisition and evaluation aims at maximizing sensitivity in order to capture structural effects between treated and non-treated participants in longitudinal fashion. In contrast, the aim of imaging in a-NGF trials is to enable detection of structural tissue alterations that either increase the risk of a negative outcome (eligibility) or may result in termination of treatment (safety).
Collapse
Affiliation(s)
- Frank W. Roemer
- Department of Radiology, Universitätsklinikum Erlangen & Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Maximiliansplatz 3, 91054 Erlangen, Germany
- Chobanian & Avedisian School of Medicine, Boston University, Boston, MA, USA
| | | | - John A. Carrino
- Department of Radiology & Imaging, Hospital for Special Surgery and Weill Cornell Medicine, New York, NY, USA
| | - Andrew J. Kompel
- Chobanian & Avedisian School of Medicine, Boston University, Boston MA, USA
| | - Luis Diaz
- Chobanian & Avedisian School of Medicine, Boston University, Boston MA, USA
| | - Daichi Hayashi
- Tufts Medical Center, Tufts Medicine, Boston, MA, USA
- Chobanian & Avedisian School of Medicine, Boston University, Boston MA, USA
| | - Michel D. Crema
- Institute of Sports Imaging, French National Institute of Sports (INSEP), Paris, France
- Chobanian & Avedisian School of Medicine, Boston University, Boston MA, USA
| | - Ali Guermazi
- Chobanian & Avedisian School of Medicine, Boston University, Boston MA, USA
- Boston VA Healthcare System, West Roxbury, MA, USA
| |
Collapse
|
8
|
Zhang Y, Zhang X, Jiang Y, Yang P, Hu X, Peng B, Yue X, Li Y, Ma P, Yuan Y, Yu Y, Liu B, Li X. 3D whole-heart noncontrast coronary MR angiography based on compressed SENSE technology: a comparative study of conventional SENSE sequence and coronary computed tomography angiography. Insights Imaging 2023; 14:35. [PMID: 36790611 PMCID: PMC9931966 DOI: 10.1186/s13244-023-01378-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 01/20/2023] [Indexed: 02/16/2023] Open
Abstract
OBJECTIVE The relatively long scan time has hampered the clinical use of whole-heart noncontrast coronary magnetic resonance angiography (NCMRA). The compressed sensitivity encoding (SENSE) technique, also known as the CS technique, has been found to improve scan times. This study aimed to identify the optimal CS acceleration factor for NCMRA. METHODS Thirty-six participants underwent four NCMRA sequences: three sequences using the CS technique with acceleration factors of 4, 5, and 6, and one sequence using the conventional SENSE technique with the acceleration factor of 2. Coronary computed tomography angiography (CCTA) was considered as a reference sequence. The acquisition times of the four NCMRA sequences were assessed. The correlation and agreement between the visible vessel lengths obtained via CCTA and NCMRA were also assessed. The image quality scores and contrast ratio (CR) of eight coronary artery segments from the four NCMRA sequences were quantitatively evaluated. RESULTS The mean acquisition time of the conventional SENSE was 343 s, while that of CS4, CS5, and CS6 was 269, 215, and 190 s, respectively. The visible vessel length from the CS4 sequence showed good correlation and agreement with CCTA. The image quality score and CR from the CS4 sequence were not statistically significantly different from those in the other groups (p > 0.05). Moreover, the image score and CR showed a decreasing trend with the increase in the CS factor. CONCLUSIONS The CS technique could significantly shorten the acquisition time of NCMRA. The CS sequence with an acceleration factor of 4 was generally acceptable for NCMRA in clinical settings to balance the image quality and acquisition time.
Collapse
Affiliation(s)
- Yang Zhang
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China ,Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Xinna Zhang
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China
| | - Yuqi Jiang
- grid.186775.a0000 0000 9490 772XDepartment of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000 Anhui China
| | - Panpan Yang
- grid.186775.a0000 0000 9490 772XDepartment of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000 Anhui China
| | - Xiankuo Hu
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Bin Peng
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | | | - Yuanyuan Li
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Peiqi Ma
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Yushan Yuan
- Department of Radiology, Fuyang People’s Hospital, Fuyang, 236015 Anhui Province China
| | - Yongqiang Yu
- grid.412679.f0000 0004 1771 3402Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032 Anhui Province China
| | - Bin Liu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China.
| | - Xiaohu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China. .,Department of Radiology, Fuyang Hospital of Anhui Medical University, Fuyang, 236000, Anhui, China.
| |
Collapse
|
9
|
Sui H, Gong Y, Liu L, Lv Z, Zhang Y, Dai Y, Mo Z. Comparison of Artificial Intelligence-Assisted Compressed Sensing (ACS) and Routine Two-Dimensional Sequences on Lumbar Spine Imaging. J Pain Res 2023; 16:257-267. [PMID: 36744117 PMCID: PMC9891076 DOI: 10.2147/jpr.s388219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 12/20/2022] [Indexed: 01/29/2023] Open
Abstract
Purpose To evaluate and compare the image quality and diagnostic accuracy of Artificial Intelligence-assisted Compressed Sensing (ACS) sequences for lumbar disease, as an acceleration method for MRI combining parallel imaging, half-Fourier, compressed sensing and neural network and routine 2D sequences for lumbar spine. Methods We collected data from 82 healthy subjects and 213 patients who used 2D ACS accelerated sequences to examine the lumbar spine while 95 healthy subjects and 234 patients used routine 2D sequences. Acquisitions included axial T2WI, sagittal T2WI, T1WI, and T2-fs sequences. All obtained images of these subjects were analyzed in the light of calculating image quality factors such as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for selected regions of interest. The lumbar image quality, artifacts and visibility of lesion structure were assessed by two radiologists independently. Differences between the evaluation values above were tested for statistical significance by the Wilcoxon signed-ranks test. Inter-observer agreements of image quality between two radiologists were measured using Cohen's kappa correlation coefficient. Results The ACS accelerated sequences not only reduced the scanning time by 18.9%, but also retained basically the same image quality as the routine 2D sequences in both healthy subjects and patients. Artifacts are less produced on ACS accelerated sequences compared with routine 2D sequences (p < 0.05). Apart from this, there were no significant differences in quantitative SNR, CNR measurements and qualitative scores within reviewing radiologists for each group (p > 0.05). Moreover, inter-observer agreement between two radiologists in scoring image quality was substantial consistently for ACS accelerated sequences and routine sequences (kappa = 0.622-0.986). Conclusion Compared with routine 2D sequences, ACS accelerated sequences allow for faster lumbar spine imaging with similar imaging quality and present reliable diagnostic accuracy, which can potentially improve workflow and patient comfort in musculoskeletal examinations.
Collapse
Affiliation(s)
- He Sui
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Yu Gong
- Medical Imaging Department, Linyi People’s Hospital, Linyi, People’s Republic of China
| | - Lin Liu
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Zhongwen Lv
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Yunfei Zhang
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, People’s Republic of China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, People’s Republic of China
| | - Zhanhao Mo
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China,Correspondence: Zhanhao Mo, Department of Radiology, China-Japan Union Hospital of Jilin University, No. 126 Xiantai St., Erdao Dist., Changchun, People’s Republic of China, Email
| |
Collapse
|
10
|
Fervers P, Zaeske C, Rauen P, Iuga AI, Kottlors J, Persigehl T, Sonnabend K, Weiss K, Bratke G. Conventional and Deep-Learning-Based Image Reconstructions of Undersampled K-Space Data of the Lumbar Spine Using Compressed Sensing in MRI: A Comparative Study on 20 Subjects. Diagnostics (Basel) 2023; 13:diagnostics13030418. [PMID: 36766523 PMCID: PMC9914543 DOI: 10.3390/diagnostics13030418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/20/2023] [Accepted: 01/21/2023] [Indexed: 01/25/2023] Open
Abstract
Compressed sensing accelerates magnetic resonance imaging (MRI) acquisition by undersampling of the k-space. Yet, excessive undersampling impairs image quality when using conventional reconstruction techniques. Deep-learning-based reconstruction methods might allow for stronger undersampling and thus faster MRI scans without loss of crucial image quality. We compared imaging approaches using parallel imaging (SENSE), a combination of parallel imaging and compressed sensing (COMPRESSED SENSE, CS), and a combination of CS and a deep-learning-based reconstruction (CS AI) on raw k-space data acquired at different undersampling factors. 3D T2-weighted images of the lumbar spine were obtained from 20 volunteers, including a 3D sequence (standard SENSE), as provided by the manufacturer, as well as accelerated 3D sequences (undersampling factors 4.5, 8, and 11) reconstructed with CS and CS AI. Subjective rating was performed using a 5-point Likert scale to evaluate anatomical structures and overall image impression. Objective rating was performed using apparent signal-to-noise and contrast-to-noise ratio (aSNR and aCNR) as well as root mean square error (RMSE) and structural-similarity index (SSIM). The CS AI 4.5 sequence was subjectively rated better than the standard in several categories and deep-learning-based reconstructions were subjectively rated better than conventional reconstructions in several categories for acceleration factors 8 and 11. In the objective rating, only aSNR of the bone showed a significant tendency towards better results of the deep-learning-based reconstructions. We conclude that CS in combination with deep-learning-based image reconstruction allows for stronger undersampling of k-space data without loss of image quality, and thus has potential for further scan time reduction.
Collapse
Affiliation(s)
- Philipp Fervers
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
- Correspondence:
| | - Charlotte Zaeske
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| | - Philip Rauen
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| | - Andra-Iza Iuga
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| | - Jonathan Kottlors
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| | - Thorsten Persigehl
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| | | | - Kilian Weiss
- Philips GmbH Market DACH, 22335 Hamburg, Germany
| | - Grischa Bratke
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, 50937 Cologne, Germany
| |
Collapse
|
11
|
Akai H, Yasaka K, Sugawara H, Tajima T, Kamitani M, Furuta T, Akahane M, Yoshioka N, Ohtomo K, Abe O, Kiryu S. Acceleration of knee magnetic resonance imaging using a combination of compressed sensing and commercially available deep learning reconstruction: a preliminary study. BMC Med Imaging 2023; 23:5. [PMID: 36624404 PMCID: PMC9827641 DOI: 10.1186/s12880-023-00962-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 01/04/2023] [Indexed: 01/10/2023] Open
Abstract
PURPOSE To evaluate whether deep learning reconstruction (DLR) accelerates the acquisition of 1.5-T magnetic resonance imaging (MRI) knee data without image deterioration. MATERIALS AND METHODS Twenty-one healthy volunteers underwent MRI of the right knee on a 1.5-T MRI scanner. Proton-density-weighted images with one or four numbers of signal averages (NSAs) were obtained via compressed sensing, and DLR was applied to the images with 1 NSA to obtain 1NSA-DLR images. The 1NSA-DLR and 4NSA images were compared objectively (by deriving the signal-to-noise ratios of the lateral and the medial menisci and the contrast-to-noise ratios of the lateral and the medial menisci and articular cartilages) and subjectively (in terms of the visibility of the anterior cruciate ligament, the medial collateral ligament, the medial and lateral menisci, and bone) and in terms of image noise, artifacts, and overall diagnostic acceptability. The paired t-test and Wilcoxon signed-rank test were used for statistical analyses. RESULTS The 1NSA-DLR images were obtained within 100 s. The signal-to-noise ratios (lateral: 3.27 ± 0.30 vs. 1.90 ± 0.13, medial: 2.71 ± 0.24 vs. 1.80 ± 0.15, both p < 0.001) and contrast-to-noise ratios (lateral: 2.61 ± 0.51 vs. 2.18 ± 0.58, medial 2.19 ± 0.32 vs. 1.97 ± 0.36, both p < 0.001) were significantly higher for 1NSA-DLR than 4NSA images. Subjectively, all anatomical structures (except bone) were significantly clearer on the 1NSA-DLR than on the 4NSA images. Also, in the former images, the noise was lower, and the overall diagnostic acceptability was higher. CONCLUSION Compared with the 4NSA images, the 1NSA-DLR images exhibited less noise, higher overall image quality, and allowed more precise visualization of the menisci and ligaments.
Collapse
Affiliation(s)
- Hiroyuki Akai
- grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639 Japan ,Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan
| | - Koichiro Yasaka
- Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan ,grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Haruto Sugawara
- grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639 Japan
| | - Taku Tajima
- Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan ,grid.415958.40000 0004 1771 6769Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo, 108-8329 Japan
| | - Masaru Kamitani
- grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639 Japan
| | - Toshihiro Furuta
- grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Institute of Medical Science, University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo, 108-8639 Japan
| | - Masaaki Akahane
- Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan
| | - Naoki Yoshioka
- Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan
| | - Kuni Ohtomo
- grid.411731.10000 0004 0531 3030International University of Health and Welfare, 2600-1 Kiakanemaru, Ohtawara, Tochigi 324-8501 Japan
| | - Osamu Abe
- grid.26999.3d0000 0001 2151 536XDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Shigeru Kiryu
- Present Address: Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda, Narita, Chiba 286-0124 Japan
| |
Collapse
|
12
|
Guermazi A, Roemer FW, Crema MD, Jarraya M, Mobasheri A, Hayashi D. Strategic application of imaging in DMOAD clinical trials: focus on eligibility, drug delivery, and semiquantitative assessment of structural progression. Ther Adv Musculoskelet Dis 2023; 15:1759720X231165558. [PMID: 37063459 PMCID: PMC10103249 DOI: 10.1177/1759720x231165558] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 03/02/2023] [Indexed: 04/18/2023] Open
Abstract
Despite decades of research efforts and multiple clinical trials aimed at discovering efficacious disease-modifying osteoarthritis (OA) drugs (DMOAD), we still do not have a drug that shows convincing scientific evidence to be approved as an effective DMOAD. It has been suggested these DMOAD clinical trials were in part unsuccessful since eligibility criteria and imaging-based outcome evaluation were solely based on conventional radiography. The OA research community has been aware of the limitations of conventional radiography being used as a primary imaging modality for eligibility and efficacy assessment in DMOAD trials. An imaging modality for DMOAD trials should be able to depict soft tissue and osseous pathologies that are relevant to OA disease progression and clinical manifestations of OA. Magnetic resonance imaging (MRI) fulfills these criteria and advances in technology and increasing knowledge regarding imaging outcomes likely should play a more prominent role in DMOAD clinical trials. In this perspective article, we will describe MRI-based tools and analytic methods that can be applied to DMOAD clinical trials with a particular emphasis on knee OA. MRI should be the modality of choice for eligibility screening and outcome assessment. Optimal MRI pulse sequences must be chosen to visualize specific features of OA.
Collapse
Affiliation(s)
| | - Frank W. Roemer
- Department of Radiology, Universitätsklinikum Erlangen & Friedrich-Alexander Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
- Department of Radiology, School of Medicine, Boston University, Boston, MA, USA
| | - Michel D. Crema
- Institute of Sports Imaging, Sports Medicine Department, French National Institute of Sports (INSEP), Paris, France
- Department of Radiology, School of Medicine, Boston University, Boston, MA, USA
| | - Mohamed Jarraya
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Ali Mobasheri
- Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland
- Department of Regenerative Medicine, State Research Institute Centre for Innovative Medicine, Vilnius, Lithuania
- Department of Joint Surgery, First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- World Health Organization Collaborating Centre for Public Health Aspects of Musculoskeletal Health and Aging, Liege, Belgium
| | - Daichi Hayashi
- Department of Radiology, Tufts Medical Center, Tufts Medicine, Boston, MA, USA
- Department of Radiology, School of Medicine, Boston University, Boston, MA, USA
| |
Collapse
|
13
|
Tolpadi AA, Han M, Calivà F, Pedoia V, Majumdar S. Region of interest-specific loss functions improve T 2 quantification with ultrafast T 2 mapping MRI sequences in knee, hip and lumbar spine. Sci Rep 2022; 12:22208. [PMID: 36564430 PMCID: PMC9789075 DOI: 10.1038/s41598-022-26266-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 12/13/2022] [Indexed: 12/24/2022] Open
Abstract
MRI T2 mapping sequences quantitatively assess tissue health and depict early degenerative changes in musculoskeletal (MSK) tissues like cartilage and intervertebral discs (IVDs) but require long acquisition times. In MSK imaging, small features in cartilage and IVDs are crucial for diagnoses and must be preserved when reconstructing accelerated data. To these ends, we propose region of interest-specific postprocessing of accelerated acquisitions: a recurrent UNet deep learning architecture that provides T2 maps in knee cartilage, hip cartilage, and lumbar spine IVDs from accelerated T2-prepared snapshot gradient-echo acquisitions, optimizing for cartilage and IVD performance with a multi-component loss function that most heavily penalizes errors in those regions. Quantification errors in knee and hip cartilage were under 10% and 9% from acceleration factors R = 2 through 10, respectively, with bias for both under 3 ms for most of R = 2 through 12. In IVDs, mean quantification errors were under 12% from R = 2 through 6. A Gray Level Co-Occurrence Matrix-based scheme showed knee and hip pipelines outperformed state-of-the-art models, retaining smooth textures for most R and sharper ones through moderate R. Our methodology yields robust T2 maps while offering new approaches for optimizing and evaluating reconstruction algorithms to facilitate better preservation of small, clinically relevant features.
Collapse
Affiliation(s)
- Aniket A Tolpadi
- Department of Radiology and Biomedical Imaging, University of California, 1700, 4th Street, San Francisco, CA, 94158, USA.
| | - Misung Han
- Department of Radiology and Biomedical Imaging, University of California, 1700, 4th Street, San Francisco, CA, 94158, USA
| | - Francesco Calivà
- Department of Radiology and Biomedical Imaging, University of California, 1700, 4th Street, San Francisco, CA, 94158, USA
| | - Valentina Pedoia
- Department of Radiology and Biomedical Imaging, University of California, 1700, 4th Street, San Francisco, CA, 94158, USA
| | - Sharmila Majumdar
- Department of Radiology and Biomedical Imaging, University of California, 1700, 4th Street, San Francisco, CA, 94158, USA
| |
Collapse
|
14
|
Kim M, Lee SM, Park C, Lee D, Kim KS, Jeong HS, Kim S, Choi MH, Nickel D. Deep Learning-Enhanced Parallel Imaging and Simultaneous Multislice Acceleration Reconstruction in Knee MRI. Invest Radiol 2022; 57:826-33. [PMID: 35776434 DOI: 10.1097/RLI.0000000000000900] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES This study aimed to examine various combinations of parallel imaging (PI) and simultaneous multislice (SMS) acceleration imaging using deep learning (DL)-enhanced and conventional reconstruction. The study also aimed at comparing the diagnostic performance of the various combinations in internal knee derangement and provided a quantitative evaluation of image sharpness and noise using edge rise distance (ERD) and noise power (NP), respectively. MATERIALS AND METHODS The data from adult patients who underwent knee magnetic resonance imaging using various DL-enhanced acquisitions between June 2021 and January 2022 were retrospectively analyzed. The participants underwent conventional 2-fold PI and DL protocols with 4- to 8-fold acceleration imaging (P2S2 [2-fold PI with 2-fold SMS], P3S2, and P4S2). Three readers evaluated the internal knee derangement and the overall image quality. The diagnostic performance was calculated using consensus reading as a standard reference, and we conducted comparative evaluations. We calculated the ERD and NP for quantitative evaluations of image sharpness and noise, respectively. Interreader and intermethod agreements were calculated using Fleiss κ. RESULTS A total of 33 patients (mean age, 49 ± 19 years; 20 women) were included in this study. The diagnostic performance for internal knee derangement and the overall image quality were similar among the evaluated protocols. The NP values were significantly lower using the DL protocols than with conventional imaging ( P < 0.001), whereas the ERD values were similar among these methods ( P > 0.12). Interreader and intermethod agreements were moderate-to-excellent (κ = 0.574-0.838) and good-to-excellent (κ = 0.755-1.000), respectively. In addition, the mean acquisition time was reduced by 47% when using DL with P2S2, by 62% with P3S2, and by 71% with P4S2, compared with conventional P2 imaging (2 minutes and 55 seconds). CONCLUSIONS The combined use of DL-enhanced 8-fold acceleration imaging (4-fold PI with 2-fold SMS) showed comparable performance with conventional 2-fold PI for the evaluation of internal knee derangement, with a 71% reduction in acquisition time.
Collapse
|
15
|
Yang F, Pan X, Zhu K, Xiao Y, Yue X, Peng P, Zhang X, Huang J, Chen J, Yuan Y, Sun J. Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T. Eur J Radiol 2022; 156:110562. [PMID: 36270194 DOI: 10.1016/j.ejrad.2022.110562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 09/18/2022] [Accepted: 10/11/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the feasibility of isotropic 3D high-resolution T2-weighted imaging (T2WI) MRI sequences and compare the images reconstructed by integrating artificial intelligence-compressed sensing (AI-CS), compressed sensing (CS), and conventional 2D T2WI sequences for quality. MATERIALS AND METHODS Fifty-two female patients (ages: 26-80 years) with suspected breast cancer were enrolled. They underwent breast MRI examinations using three sequences: conventional T2WI, CS 3D T2WI, and AI-CS 3D T2WI. Image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio, tumor volume, and maximal tumor diameter were compared using the Friedman test. Image quality was scored on a 5-point scale, with 1 indicating nonassessable quality and 5 indicating excellent quality. Tumor volume and maximal tumor diameter were compared based on AI-CS 3D T2WI (slightly high signal), conventional T2WI, and dynamic contrast-enhanced (DCE) sequences. RESULTS All three T2WI were successfully performed in all patients. 3D CS and AI-CS were significantly better than conventional T2WI in terms of lesion conspicuity and morphology, structural details, overall image quality, diagnostic information for breast lesions, and breast tissue delineation (P < 0.001). The SNR of conventional T2WI was significantly higher for 3D T2WI sequences. The contrast-to-noise ratio was significantly higher for AI-CS 3D T2WI than for conventional T2WI sequence. There was no significant difference in tumor volume between DCE (8.08 ± 16.51) and AI-CS 3D T2WI (8.25 ± 16.29) sequences and no significant differences in tumor diameter among DCE, AI-CS 3D T2WI, and conventional T2WI sequences. CONCLUSION Isotropic-resolution 3D T2WI sequences can be acquired using AI-CS while maintaining image quality and diagnostic value, which may pave the way for isotropic 3D high-resolution T2WI for clinical application.
Collapse
Affiliation(s)
- Fan Yang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Xuelin Pan
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Ke Zhu
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Yitian Xiao
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Xun Yue
- Department of Radiology, North Sichuan Medical College, Nanchong, China
| | - Pengfei Peng
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | | | - Juan Huang
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Jie Chen
- Department of Breast Surgery, West China Hospital of Sichuan University, Chengdu, China
| | - Yuan Yuan
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| | - Jiayu Sun
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| |
Collapse
|
16
|
Hou Y, Liu Q, Chen J, Wu B, Zeng F, Yang Z, Song H, Liu Y. Application value of T2 fluid-attenuated inversion recovery sequence based on deep learning in static lacunar infarction. Acta Radiol 2022; 64:1650-1658. [PMID: 36285480 DOI: 10.1177/02841851221134114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Regular monitoring of static lacunar infarction (SLI) lesions plays an important role in preventing disease development and managing prognosis. Magnetic resonance imaging is one method used to monitor SLI lesions. Purpose To evaluate the image quality of the T2 fluid-attenuated inversion recovery (T2-FLAIR) sequence using artificial intelligence-assisted compressed sensing (ACS) in detecting SLI lesions and assess its clinical applicability. Methods A total of 42 patients were prospectively enrolled and scanned by T2-FLAIR. Two independent readers reviewed the images acquired with accelerated modes 1D (acceleration factor 2) and ACS (acceleration factors 2, 3, and 4). The overall image quality and lesion image quality were analyzed, as were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and number of lesions between groups. Results The subjective assessment of overall brain image quality and lesion image quality was consistent between the two readers. The lesion display quality and the overall image quality were better with the traditional 1D acceleration method than with the ACS accelerated method. There was no significant difference in the SNR of the lacunar infarction in the images between the groups. The CNR of the images with the 1D acceleration mode was significantly lower than that of images with the ACS acceleration mode. Images with the 1D, ACS2, and ACS3 acceleration modes showed no significant differences in terms of detecting lesions but scan time can be reduced by 40% (1D vs. ACS3). Conclusion ACS acceleration mode can greatly reduce the scan time. In addition, the images have good SNR, high CNR, and strong SLI lesion detection ability.
Collapse
Affiliation(s)
- Yanzhen Hou
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Qian Liu
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Jialing Chen
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Bin Wu
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Feihong Zeng
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Zhongxian Yang
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| | - Haiyan Song
- Department of Radiology, 499778Shenzhen Second People's Hospital, Shenzhen, Guangdong Province, PR China
| | - Yubao Liu
- Medical Imaging Center, 559569Shenzhen Hospital of Southern Medical University, Shenzhen, Guangdong Province, PR China
| |
Collapse
|
17
|
Minssen L, Renoux J, Abar G, Moya L, Brasseur JL, Li L, Crema MD. Three-dimensional turbo spin-echo (TSE) MRI assessment of indirect acute muscle injuries in athletes: comparison with two-dimensional TSE MRI. Eur Radiol 2022; 33:587-594. [PMID: 35927467 DOI: 10.1007/s00330-022-09005-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 06/09/2022] [Accepted: 06/30/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVE To evaluate three-dimensional (3D) turbo spin-echo (TSE) magnetic resonance imaging (MRI) for the assessment of acute muscle injuries in elite athletes in comparison with two-dimensional (2D) MRI. METHODS Elite athletes with clinically suspected acute muscle injury of the thigh who underwent both 2D and 3D MRI protocols on the same day were retrospectively included. Two musculoskeletal radiologists independently assessed 2D and 3D MRIs, with both techniques evaluated separately 1-month apart. Muscle injuries were evaluated using the BAMIC and the INSEP classifications. A second assessment of injuries was performed by each reader 2 months after the initial readings. Agreement was determined using weighted kappa statistics. The level of diagnostic confidence in classifying injuries was also assessed for both MRI protocols. RESULTS A total of 40 athletes were included. Intra-reader agreement when comparing injury grades from 2D vs. 3D for both INSEP and BAMIC classifications was almost perfect for both readers and ranged between 0.84 and 0.98. Inter-reader agreement was substantial to almost perfect and ranged from 0.78 to 0.93 for the 2D protocol, and from 0.78 to 0.95 for the 3D protocol. Intra-reader agreement for each MRI protocol separately was almost perfect to perfect for both readers and ranged between 0.84 and 1.00. Diagnostic confidence for grading injuries improved for both readers when using the 3D protocol. CONCLUSIONS Compared to 2D MRI, 3D TSE MRI is a reliable technique for acute muscular injury assessment, providing faster acquisition times and improving the diagnostic confidence. KEY POINTS • Compared to 2D MRI, 3D TSE MRI is a reliable technique for the assessment of acute muscular injuries. • 3D TSE MRI has the advantage of faster total acquisition times, thinner sections, and multiplanar reconstruction, improving the confidence for structural assessment including connective tissue involvement.
Collapse
Affiliation(s)
- Lise Minssen
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France.,Department of Radiology, Saint-Antoine Hospital, APHP, UPMC Sorbonne University, Paris, France
| | - Jérôme Renoux
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France.,Department of Radiology, American Hospital of Paris, Paris, France
| | - Guillaume Abar
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France
| | - Loris Moya
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France.,Department of Radiology, American Hospital of Paris, Paris, France
| | - Jean-Louis Brasseur
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France.,Department of Radiology, Imagerie Médicale de la Plaine de France (IMPF), Montfermeil, France
| | - Ling Li
- Department of Statistics, Pfizer Inc., New York, NY, USA
| | - Michel D Crema
- Institute of Sports Imaging, French National Institute of Sports (INSEP), 11 Avenue du Tremblay, 75012, Paris, France. .,Department of Sports Medicine, French National Institute of Sports (INSEP), Paris, France. .,Department of Radiology, Quantitative Imaging Center, Boston University School of Medicine, Boston, MA, USA.
| |
Collapse
|
18
|
Thakur U, Gulati V, Shah J, Tietze D, Chhabra A. Anterior cruciate ligament reconstruction related complications: 2D and 3D high-resolution magnetic resonance imaging evaluation. Skeletal Radiol 2022; 51:1347-1364. [PMID: 34977965 DOI: 10.1007/s00256-021-03982-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/16/2021] [Accepted: 12/17/2021] [Indexed: 02/02/2023]
Abstract
Anterior cruciate ligament (ACL) injury is a common indication for sports-related major surgery and accounts for a large proportion of ligamentous injuries in athletes. The advancements in 2D and 3D MR imaging have provided considerable potential for a one-stop shop radiation-free assessment with an all-in-one modality examination of the knee, for both soft-tissue and bone evaluations. This article reviews ACL injuries and types of surgical managements with illustrative examples using high resolution 2D and 3D MR imaging. Various complications of ACL reconstruction procedures are highlighted with a focus on the use of advanced MR imaging and relevant arthroscopic correlations.
Collapse
Affiliation(s)
- Uma Thakur
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Vaibhav Gulati
- Department of Radiology, Imaging Associates at National Heart Institute, New Delhi, India
| | - Jay Shah
- Department of Orthopaedic Surgery, UT Southwestern Medical Center, Dallas, Texas, USA
| | - David Tietze
- Department of Orthopaedic Surgery, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Avneesh Chhabra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA. .,Department of Orthopaedic Surgery, UT Southwestern Medical Center, Dallas, Texas, USA.
| |
Collapse
|
19
|
de Castro Luna R, Kumar NM, Fritz J, Ahlawat S, Fayad LM. MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time. Eur Radiol 2022. [PMID: 35751699 DOI: 10.1007/s00330-022-08937-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/24/2022] [Accepted: 05/30/2022] [Indexed: 11/04/2022]
Abstract
OBJECTIVES To test whether a 4-fold accelerated 3D T2-weighted (T2) CAIPIRINHA SPACE TSE sequence with isotropic voxel size is equivalent to conventional 2DT2 TSE for the evaluation of intrinsic and perilesional soft tissue tumors (STT) characteristics. METHODS For 108 patients with histologically-proven STTs, MRI, including 3DT2 (CAIPIRINHA SPACE TSE) and 2DT2 (TSE) sequences, was performed. Two radiologists evaluated each sequence for quality (diagnostic, non-diagnostic), tumor characteristics (heterogeneity, signal intensity, margin), and the presence or absence of cortical involvement, marrow edema, and perilesional edema (PLE); tumor size and PLE extent were measured. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and acquisition times for 2DT2 in two planes and 3DT2 sequences were reported. Descriptive statistics and inter-method agreement were reported. RESULTS Image quality was diagnostic for all sequences (100% [108/108]). No difference was observed between 3DT2 and 2DT2 tumor characteristics (p < 0.05). There was no difference in mean tumor size (3DT2: 2.9 ± 2.5 cm, 2DT2: 2.8 ± 2.6 cm, p = 0.4) or PLE extent (3DT2:0.5 ± 1.2 cm, 2DT2:0.5 ± 1.0 cm, p = 0.9) between the sequences. There was no difference in the SNR of tumors, marrow, and fat between the sequences, whereas the SNR of muscle was higher (p < 0.05) on 3DT2 than 2DT2. CNR measures on 3DT2 were similar to 2DT2 (p > 0.1). The average acquisition time was shorter for 3DT2 compared with 2DT2 (343 ± 127 s vs 475 ± 162 s, respectively). CONCLUSION Isotropic 3DT2 MRI offers higher spatial resolution, faster acquisition times, and equivalent assessments of STT characteristics compared to conventional 2DT2 MRI in two planes. 3DT2 is interchangeable with a 2DT2 sequence in tumor protocols. KEY POINTS • Isotropic 3DT2 CAIPIRINHA SPACE TSE offers higher spatial resolution than 2DT2 TSE and is equivalent to 2DT2 TSE for assessments of soft tissue tumor intrinsic and perilesional characteristics. • Multiplanar reformats of 3DT2 CAIPIRINHA SPACE TSE can substitute for 2DT2 TSE acquired in multiple planes, thereby reducing the acquisition time of MRI tumor protocols. • 3DT2 CAIPIRINHA SPACE TSE and 2DT2 TSE had similar CNR of tissues.
Collapse
|
20
|
Kakigi T, Sakamoto R, Tagawa H, Kuriyama S, Goto Y, Nambu M, Sagawa H, Numamoto H, Miyake KK, Saga T, Matsuda S, Nakamoto Y. Diagnostic advantage of thin slice 2D MRI and multiplanar reconstruction of the knee joint using deep learning based denoising approach. Sci Rep 2022; 12:10362. [PMID: 35725760 PMCID: PMC9209466 DOI: 10.1038/s41598-022-14190-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 06/02/2022] [Indexed: 11/16/2022] Open
Abstract
The purpose of this study is to evaluate whether thin-slice high-resolution 2D fat-suppressed proton density-weighted image of the knee joint using denoising approach with deep learning-based reconstruction (dDLR) with MPR is more useful than 3D FS-PD multi planar voxel image. Twelve patients who underwent MRI of the knee at 3T and 13 knees were enrolled. Denoising effect was quantitatively evaluated by comparing the coefficient of variation (CV) before and after dDLR. For the qualitative assessment, two radiologists evaluated image quality, artifacts, anatomical structures, and abnormal findings using a 5-point Likert scale between 2D and 3D. All of them were statistically analyzed. Gwet’s agreement coefficients were also calculated. For the scores of abnormal findings, we calculated the percentages of the cases with agreement with high confidence. The CV after dDLR was significantly lower than the one before dDLR (p < 0.05). As for image quality, artifacts and anatomical structure, no significant differences were found except for flow artifact (p < 0.05). The agreement was significantly higher in 2D than in 3D in abnormal findings (p < 0.05). In abnormal findings, the percentage with high confidence was higher in 2D than in 3D (p < 0.05). By applying dDLR to 2D, almost equivalent image quality to 3D could be obtained. Furthermore, abnormal findings could be depicted with greater confidence and consistency, indicating that 2D with dDLR can be a promising imaging method for the knee joint disease evaluation.
Collapse
Affiliation(s)
- Takahide Kakigi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Ryo Sakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Preemptive Medicine and Lifestyle-Related Disease Research Center, Kyoto University Hospital, 53 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Hiroshi Tagawa
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shinichi Kuriyama
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yoshihito Goto
- Department of Health Informatics, Kyoto University Graduate School of Medicine/School of Public Health, Yoshida Konoe-cho, Sakyo-ku, Kyoto, 606-8501, Japan
| | - Masahito Nambu
- MRI Systems Division, Canon Medical Systems Corporation, 1385 Shimoishigami, Otawara, Tochigi, 324-8550, Japan
| | - Hajime Sagawa
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Hitomi Numamoto
- Department of Advanced Medical Imaging Research, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kanae Kawai Miyake
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Department of Advanced Medical Imaging Research, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Tsuneo Saga
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.,Department of Advanced Medical Imaging Research, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
21
|
Van Dyck P, Smekens C, Roelant E, Vande Vyvere T, Snoeckx A, De Smet E. 3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study. Eur Radiol 2022. [PMID: 35353196 DOI: 10.1007/s00330-022-08715-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 02/03/2022] [Accepted: 03/05/2022] [Indexed: 11/04/2022]
Abstract
OBJECTIVE To perform a large-scale interchangeability study comparing 3D controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) TSE with standard 2D TSE for knee MRI. METHODS In this prospective study, 250 patients underwent 3 T knee MRI, including a multicontrast 3D CAIPIRINHA SPACE TSE (9:26 min) and a standard 2D TSE protocol (12:14 min). Thirty-three (13%) patients had previous anterior cruciate ligament and/or meniscus surgery. Two radiologists assessed MRIs for image quality and identified pathologies of menisci, ligaments, and cartilage by using a 4-point Likert scale according to the level of diagnostic confidence. Interchangeability of the protocols was tested under the same-reader scenario using a bootstrap percentile confidence interval. Interreader reliability and intermethod concordance were also evaluated. RESULTS Despite higher image quality and diagnostic confidence for standard 2D TSE compared to 3D CAIPIRINHA SPACE TSE, the protocols were found interchangeable for diagnosing knee abnormalities, except for patellar (6.8% difference; 95% CI: 4.0, 9.6) and trochlear (3.6% difference; 95% CI: 0.8, 6.6) cartilage defects. The interreader reliability was substantial to almost perfect for 2D and 3D MRI (range κ, 0.785-1 and κ, 0.725-0.964, respectively). Intermethod concordance was almost perfect for all diagnoses (range κ, 0.817-0.986). CONCLUSION Multicontrast 3D CAIPIRINHA SPACE TSE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. Despite the radiologist's preference for 2D TSE imaging, a pursuit towards time-saving 3D TSE knee MRI is justified for routine practice. KEY POINTS • Multicontrast 3D CAIPIRINHA SPACE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. • Radiologists are more confident in diagnosing knee abnormalities on 2D TSE than on 3D CAIPIRINHA SPACE TSE MRI. • Despite the radiologist's preference for 2D TSE, a pursuit towards accelerated 3D TSE knee MRI is justified for routine practice.
Collapse
|
22
|
Ding J, Duan Y, Wang M, Yuan Y, Zhuo Z, Gan L, Song Q, Gao B, Yang L, Liu H, Hou Y, Zheng F, Chen R, Wang J, Lin L, Zhang B, Zhang G, Liu Y. Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study. AJNR Am J Neuroradiol 2022; 43:402-409. [PMID: 35241421 PMCID: PMC8910792 DOI: 10.3174/ajnr.a7441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 10/17/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra-red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra-red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra-red nucleus and internal cerebral vein.
Collapse
Affiliation(s)
- J. Ding
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Y. Duan
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - M. Wang
- Department of Radiology (M.W., B.Z.), The Affiliated Drum Tower Hospital of Nanjing UniversityMedical School, Jiangsu, China
| | - Y. Yuan
- Department of Radiology (Y.Y., G.Z.), Beijing Royal Integrative Medicine Hospital, Beijing, China
| | - Z. Zhuo
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - L. Gan
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Q. Song
- Department of Radiology (Q.S., B.G.), First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - B. Gao
- Department of Radiology (Q.S., B.G.), First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - L. Yang
- Department of Radiology (L.Y., H.L., Y.H.), Shengjing Hospital of ChinaMedical University, Shenyang, China
| | - H. Liu
- Department of Radiology (L.Y., H.L., Y.H.), Shengjing Hospital of ChinaMedical University, Shenyang, China
| | - Y. Hou
- Department of Radiology (L.Y., H.L., Y.H.), Shengjing Hospital of ChinaMedical University, Shenyang, China
| | - F. Zheng
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - R. Chen
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - J. Wang
- Philips Healthcare (J.W., L.L.), Beijing, China
| | - L. Lin
- Philips Healthcare (J.W., L.L.), Beijing, China
| | - B. Zhang
- Department of Radiology (M.W., B.Z.), The Affiliated Drum Tower Hospital of Nanjing UniversityMedical School, Jiangsu, China
| | - G. Zhang
- Department of Radiology (Y.Y., G.Z.), Beijing Royal Integrative Medicine Hospital, Beijing, China
| | - Y. Liu
- From the Department of Radiology (J.D., Y.D., Z.Z., L.G., F.Z., R.C., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
23
|
Sui H, Li J, Liu L, Lv Z, Zhang Y, Dai Y, Mo Z. Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing. J Pain Res 2022; 15:577-590. [PMID: 35241934 PMCID: PMC8887673 DOI: 10.2147/jpr.s345210] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 01/28/2022] [Indexed: 11/29/2022] Open
Abstract
Purpose The three-dimensional (3D) sequence of magnetic resonance imaging (MRI) plays a critical role in the imaging of musculoskeletal joints; however, its long acquisition time limits its clinical application. In such conditions, compressed sensing (CS) is introduced to accelerate MRI in clinical practice. We aimed to investigate the feasibility of an isotropic 3D variable-flip-angle fast spin echo (FSE) sequence with CS technique (CS-MATRIX) compared to conventional 2D sequences in knee imaging. Methods Images from different sequences of both the accelerated CS-MATRIX and the corresponding conventional acquisitions were prospectively analyzed and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the structures within the knees were measured for quantitative analysis. The subjective image quality and diagnostic agreement were compared between CS-MATRIX and conventional 2D sequences. Quantitative and subjective image quality scores were statistically analyzed with the paired t-test and Wilcoxon signed-rank test, respectively. Diagnostic agreements of knee substructure were assessed using Cohen’s weighted kappa statistic. Results For quantitative analysis, images from the CS-MATRIX sequence showed a significantly higher SNR than T2-fs 2D sequences for visualizing cartilage, menisci, and ligaments, as well as a higher SNR than proton density (pd) 2D sequences for visualizing menisci and ligaments. There was no significant difference between CS-MATRIX and 2D T2-fs sequences in subjective image quality assessment. The diagnostic agreement was rated as moderate to very good between CS-MATRIX and 2D sequences. Conclusion This study demonstrates the feasibility and clinical potential of the CS-MATRIX sequence technique for detecting knee lesions The CS-MATRIX sequence allows for faster knee imaging than conventional 2D sequences, yielding similar image quality to 2D sequences.
Collapse
Affiliation(s)
- He Sui
- China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Jin Li
- Jilin Province People’s Hospital, Changchun, People’s Republic of China
- The Department of Trauma Surgery, Shanghai Oriental Hospital, Shanghai, People's Republic of China
| | - Lin Liu
- China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Zhongwen Lv
- China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Yunfei Zhang
- Central Research Institute, United Imaging Healthcare, Shanghai, 201800, People’s Republic of China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, 201800, People’s Republic of China
| | - Zhanhao Mo
- China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
- Correspondence: Zhanhao Mo, China-Japan Union Hospital of Jilin University, No. 126 Xiantai Street, Erdao District, Changchun, People’s Republic of China, Email
| |
Collapse
|
24
|
Peng S, Guo Y, Zhang X, Tao J, Liu J, Zhu W, Chen L, Yang F. High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions. Diagnostics (Basel) 2021; 11:2273. [PMID: 34943509 DOI: 10.3390/diagnostics11122273] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 11/19/2022] Open
Abstract
To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10−3 vs. 1.43 × 10−3 mm2/s, p = 0.702; malignant 0.91 × 10−3 vs. 0.89 × 10−3 mm2/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast.
Collapse
|
25
|
Abstract
Three-dimensional (3D) magnetic resonance imaging (MRI) of the knee is widely used in musculoskeletal (MSK) imaging. Currently, 3D sequences are most commonly used for morphological imaging. Isotropic 3D MRI provides higher out-of-plane resolution than standard two-dimensional (2D) MRI, leading to reduced partial volume averaging artifacts and allowing for multiplanar reconstructions in any plane with any thickness from a single high-resolution isotropic acquisition. Specifically, isotropic 3D fast spin-echo imaging, with options for tissue weighting similar to those used in multiplanar 2D FSE imaging, is of particular interest to MSK radiologists. New applications for 3D spatially encoded sequences are also increasingly available for clinical use. These applications offer advantages over standard 2D techniques for metal artifact reduction, quantitative cartilage imaging, nerve imaging, and bone shape analysis. Emerging fast imaging techniques can be used to overcome the long acquisition times that have limited the adoption of 3D imaging in clinical protocols.
Collapse
Affiliation(s)
- Faysal Altahawi
- Section of Musculoskeletal Imaging, Imaging Institute, Cleveland Clinic, Cleveland, Ohio
| | - Jason Pierce
- Diagnostic Radiology Residency, Imaging Institute, Cleveland Clinic, Cleveland, Ohio
| | - Mercan Aslan
- Section of Musculoskeletal Imaging, Imaging Institute, Cleveland Clinic, Cleveland, Ohio
| | - Xiaojuan Li
- Section of Musculoskeletal Imaging, Imaging Institute, Cleveland Clinic, Cleveland, Ohio.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Carl S Winalski
- Section of Musculoskeletal Imaging, Imaging Institute, Cleveland Clinic, Cleveland, Ohio.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Naveen Subhas
- Section of Musculoskeletal Imaging, Imaging Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
26
|
Gao T, Lu Z, Wang F, Zhao H, Wang J, Pan S. Using the Compressed Sensing Technique for Lumbar Vertebrae Imaging: Comparison with Conventional Parallel Imaging. Curr Med Imaging 2021; 17:1010-1017. [PMID: 33573574 PMCID: PMC8653421 DOI: 10.2174/1573405617666210126155814] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 12/17/2020] [Accepted: 12/22/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To compare conventional sensitivity encoding turbo spin-echo (SENSE-TSE) with compressed sensing plus SENSE turbo spin-echo (CS-TSE) in lumbar vertebrae magnetic resonance imaging (MRI). METHODS This retrospective study of lumbar vertebrae MRI included 600 patients; 300 patients received SENSE-TSE and 300 patients received CS-TSE. The SENSE acceleration factor was 1.4 for T1WI, 1.7 for T2WI, and 1.7 for PDWI. The CS total acceleration factor was 2.4, 3.6, 4.0, and 4.0 for T1WI, T2WI, PDWI sagittal, and T2WI transverse, respectively. The image quality of each MRI sequence was evaluated objectively by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and subjectively on a five-point scale. Two radiologists independently reviewed the MRI sequences of the 300 patients receiving CS-TSE, and their diagnostic consistency was evaluated. The degree of intervertebral foraminal stenosis and nerve root compression was assessed using the T1WI sagittal and T2WI transverse images. RESULTS The scan time was reduced from 7 min 28 s to 4 min 26 s with CS-TSE. The median score of nerve root image quality was 5 (p > 0.05). The diagnostic consistency using CS-TSE images between the two radiologists was high for diagnosing lumbar diseases (κ > 0.75) and for evaluating the degree of lumbar foraminal stenosis and nerve root compression (κ = 0.882). No differences between SENSE-TSE and CS-TSE were observed for sensitivity, specificity, positive predictive value, or negative predictive value. CONCLUSION CS-TSE has the potential for diagnosing lumbar vertebrae and disc disorders.
Collapse
Affiliation(s)
- Tianyang Gao
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Zhao Lu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Fengzhe Wang
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Heng Zhao
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Jiazheng Wang
- Department of Clinical Science, Philips Healthcare, Beijing 100600, China
| | - Shinong Pan
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| |
Collapse
|
27
|
Jiang Y, Wang X, Zhu L, Liu J, Zhang X, Hu X, Lin Z, Wang K, Qin N. Compressed-sensing accelerated magnetic resonance imaging of inner ear. J Appl Clin Med Phys 2021; 22:332-338. [PMID: 34347931 PMCID: PMC8425888 DOI: 10.1002/acm2.13383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Revised: 07/09/2021] [Accepted: 07/21/2021] [Indexed: 12/01/2022] Open
Abstract
Objective To compare conventional method and compressed‐sensing (CS) accelerated 3D balanced fast field echo imaging (bFFE) of inner ear. Methods Twenty patients with suspected inner ear disease underwent CS accelerated 3D‐bFFE (CS‐bFFE) and conventional 3D‐bFFE (Con‐bFFE) by a 3T MRI. The overall image quality, motion artifacts, and image quality of specific structures of inner ear were assessed on ordinal scales by three radiologists who were blinded to the scan protocols. Kendall W test was used to evaluate interobserver agreement and Wilcoxon test was performed to compare the image quality and motion artifacts between CS‐bFFE and Con‐bFFE. Results The acquisition duration of CS‐bFFE (1 min 53 s) was 49% faster than Con‐bFFE. Three radiologists had good inter‐observer agreement of image quality (Kendall W value of 0.829 for CS‐bFFE and 0.815 for Con‐bFFE) and motion artifacts evaluation (Kendall W value of 0861 for CS‐bFFE and 0.707 for Con‐bFFE). The better overall image quality of CS‐bFFE was assessed (4.93 ± 0.23 for CS‐bFFE, 4.53 ± 0.70 for Con‐bFFE, Z = −2.254, p = 0.024). The image quality score of facial and cochlear nerve gained higher in CS‐bFFE (4.93 ± 0.23 for CS‐bFFE, 4.58 ± 0.64 for Con‐bFFE, Z = −2.094, p = 0.036). No significant difference of motion artifacts (p = 0.050) between CS‐bFFE and Con‐bFFE. Conclusions The CS‐bFFE improves image quality and reduces acquisition time significantly, and it is a feasible MRI protocol for inner ear imaging.
Collapse
Affiliation(s)
- Yuan Jiang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaoying Wang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Lina Zhu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Jing Liu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaodong Zhang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaoyu Hu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Zhiyong Lin
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Ke Wang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Naishan Qin
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| |
Collapse
|
28
|
Sartoretti T, Sartoretti E, van Smoorenburg L, Schwenk Á, Mannil M, Graf N, Binkert CA, Wyss M, Sartoretti-Schefer S. Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging. Invest Radiol 2020; 55:775-84. [PMID: 32816415 DOI: 10.1097/RLI.0000000000000705] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Spiral magnetic resonance imaging acquisition may enable improved image quality and higher scan speeds than Cartesian trajectories. We tested the performance of four 3D T1-weighted (T1w) TFE sequences (magnetization-prepared gradient echo magnetic resonance sequence) with isotropic spatial resolution for brain imaging at 1.5 T in a clinical patient cohort based on qualitative and quantitative image quality metrics. Two prototypical spiral TFE sequences (spiral 1.0 and spiral 0.85) and a Cartesian compressed sensing technology accelerated TFE sequence (CS 2.5; acceleration factor of 2.5) were compared with a conventional (reference standard) Cartesian parallel imaging accelerated TFE sequence (SENSE; acceleration factor of 1.8). MATERIALS AND METHODS The SENSE (5:52 minutes), CS 2.5 (3:17 minutes), and spiral 1.0 (2:16 minutes) sequences all had identical spatial resolutions (1.0 mm). The spiral 0.85 (3:47 minutes) had a higher spatial resolution (0.85 mm). The 4 TFE sequences were acquired in 41 patients (20 with and 21 without contrast media). Three readers rated qualitative image quality (12 categories) and selected their preferred sequence for each patient. Two readers performed quantitative analysis whereby 6 metrics were derived: contrast-to-noise ratio for white and gray matter (CNRWM/GM), contrast ratio for gray matter-CSF (CRGM/CSF), and white matter-CSF (CRWM/CSF); and coefficient of variations for gray matter (CVGM), white matter (CVWM), and CSF (CVCSF). Friedman tests with post hoc Nemenyi tests, exact binomial tests, analysis of variance with post hoc Dunnett tests, and Krippendorff alphas were computed. RESULTS Concerning qualitative analysis, the CS 2.5 sequence significantly outperformed the SENSE in 4/1 (with/without contrast) categories, whereas the spiral 1.0 and spiral 0.85 showed significantly improved scores in 10/9and 7/7 categories, respectively (P's < 0.001-0.039). The spiral 1.0 was most frequently selected as the preferred sequence (reader 1, 10/15 times; reader 2, 9/12 times; reader 3, 11/13times [with/without contrast]). Interreader agreement ranged from substantial to almost perfect (alpha = 0.615-0.997). Concerning quantitative analysis, compared with the SENSE, the CS 2.5 had significantly better scores in 2 categories (CVWM, CVCSF) and worse scores in 2 categories (CRGM/CSF, CRWM/CSF), the spiral 1.0 had significantly improved scores in 4 categories (CNRWM/GM, CRGM/CSF, CRWM/CSF, CVWM), and the spiral 0.85 had significantly better scores in 2 categories (CRGM/CSF, CRWM/CSF). CONCLUSIONS Spiral T1w TFE sequences may deliver high-quality clinical brain imaging, thus matching the performance of conventional parallel imaging accelerated T1w TFEs. Imaging can be performed at scan times as short as 2:16 minutes per sequence (61.4% scan time reduction compared with SENSE). Optionally, spiral imaging enables increased spatial resolution while maintaining the scan time of a Cartesian-based acquisition schema.
Collapse
|
29
|
Van Dyck P, Smekens C, Vanhevel F, De Smet E, Roelant E, Sijbers J, Jeurissen B. Super-Resolution Magnetic Resonance Imaging of the Knee Using 2-Dimensional Turbo Spin Echo Imaging. Invest Radiol 2021; 55:481-493. [PMID: 32404629 DOI: 10.1097/rli.0000000000000676] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVES The purpose of this study was to assess the technical feasibility of 3-dimensional (3D) super-resolution reconstruction (SRR) of 2D turbo spin echo (TSE) knee magnetic resonance imaging (MRI) and to compare its image quality with conventional 3D TSE sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) MRI. MATERIALS AND METHODS Super-resolution reconstruction 2D TSE MRI and 3D TSE SPACE images were acquired from a phantom and from the knee of 22 subjects (8 healthy volunteers and 14 patients) using a clinical 3-T scanner. For SRR, 7 anisotropic 2D TSE stacks (voxel size, 0.5 × 0.5 × 2.0 mm; scan time per stack, 1 minute 55 seconds; total scan time, 13 minutes 25 seconds) were acquired with the slice stack rotated around the phase-encoding axis. Super-resolution reconstruction was performed at an isotropic high-resolution grid with a voxel size of 0.5 × 0.5 × 0.5 mm. Direct isotropic 3D image acquisition was performed with the conventional SPACE sequence (voxel size, 0.5 × 0.5 × 0.5 mm; scan time, 12 minutes 42 seconds). For quantitative evaluation, perceptual blur metrics and edge response functions were obtained in the phantom image, and signal-to-noise and contrast-to-noise ratios were measured in the images from the healthy volunteers. Images were qualitatively evaluated by 2 independent radiologists in terms of overall image quality, edge blurring, anatomic visibility, and diagnostic confidence to assess normal and abnormal knee structures. Nonparametric statistical analysis was performed, and significance was defined for P values less than 0.05. RESULTS In the phantom, perceptual blur metrics and edge response functions demonstrated a clear improvement in spatial resolution for SRR compared with conventional 3D SPACE. In healthy subjects, signal-to-noise and contrast-to-noise ratios in clinically relevant structures were not significantly different between SRR and 3D SPACE. Super-resolution reconstruction provided better overall image quality and less edge blurring than conventional 3D SPACE, yet the perceived image contrast was better for 3D SPACE. Super-resolution reconstruction received significantly better visibility scores for the menisci, whereas the visibility of cartilage was significantly higher for 3D SPACE. Ligaments had high visibility on both SRR and 3D SPACE images. The diagnostic confidence for assessing menisci was significantly higher for SRR than for conventional 3D SPACE, whereas there were no significant differences between SRR and 3D SPACE for cartilage and ligaments. The interreader agreement for assessing menisci was substantial with 3D SPACE and almost perfect with SRR, and the agreement for assessing cartilage was almost perfect with 3D SPACE and moderate with SRR. CONCLUSIONS We demonstrate the technical feasibility of SRR for high-resolution isotropic knee MRI. Our SRR results show superior image quality in terms of edge blurring, but lower image contrast and fluid brightness when compared with conventional 3D SPACE acquisitions. Further contrast optimization and shortening of the acquisition time with state-of-the-art acceleration techniques are necessary for future clinical validation of SRR knee MRI.
Collapse
Affiliation(s)
- Pieter Van Dyck
- From the Department of Radiology, Antwerp University Hospital and University of Antwerp, Edegem
| | | | - Floris Vanhevel
- From the Department of Radiology, Antwerp University Hospital and University of Antwerp, Edegem
| | - Eline De Smet
- From the Department of Radiology, Antwerp University Hospital and University of Antwerp, Edegem
| | - Ella Roelant
- Clinical Trial Center (CTC), CRC Antwerp, Antwerp University Hospital and University of Antwerp, Edegem
| | - Jan Sijbers
- imec-Vision Lab, Department of Physics, University of Antwerp, Wilrijk, Belgium
| | - Ben Jeurissen
- imec-Vision Lab, Department of Physics, University of Antwerp, Wilrijk, Belgium
| |
Collapse
|
30
|
Bratke G, Rau R, Kabbasch C, Zäske C, Maintz D, Haneder S, Große Hokamp N, Persigehl T, Siedek F, Weiss K. Speeding up the clinical routine: Compressed sensing for 2D imaging of lumbar spine disc herniation. Eur J Radiol 2021; 140:109738. [PMID: 33945923 DOI: 10.1016/j.ejrad.2021.109738] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/20/2021] [Accepted: 04/23/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Increasing economic pressure and patient demands for comfort require an ever-increasing acceleration of scan times without compromising diagnostic certainty. This study tested the new acceleration technique Compressed SENSE (CS-SENSE) as well as different reconstruction methods for the lumbar spine. METHODS In this prospective study, 10 volunteers and 14 patients with lumbar disc herniation were scanned using a sagittal 2D T2 turbo spin echo (TSE) sequence applying different acceleration factors of SENSE and CS-SENSE. Gradient echo (GRE), autocalibration (CS-Auto) and TSE prescans were tested for reconstruction. Images were analysed by two readers regarding anatomical delineation, diagnostic certainty (for patients only) and image quality as well as objectively calculating the root mean square error (RMSE), structural similarity index (SSIM), SNR and CNR. The Friedman test and Chi-squared were used for ordinal, ANOVA for repeated measurements and Tukey Kramer test for continuous data. Cohen's kappawas calculated for interreader reliability. RESULTS CS-SENSE outperformed SENSE and CS-Auto regarding RMSE (e.g. CS-SENSE 1.5: 43.03 ± 11.64 versus SENSE 1.5: 80.41 ± 17.66; p = 0.0038) and SSIM as well as in the subjective rating for CS-SENSE 3 TSE. In the patient setting image quality was unchanged in all subjective criteria up to CS-SENSE 3 TSE (all p > 0.05) compared to standard T2 with 43 % less scan time while the GRE prescan only allowed a reduction of 32 %. CONCLUSION Combining a TSE prescan with CS-SENSE enables significant scan time reductions with unchanged ratings for lumbar spine disc herniation making this superior to the currently used SENSE acceleration or GRE reconstructions.
Collapse
Affiliation(s)
- Grischa Bratke
- Department of Radiology, University of Cologne, Cologne, Germany.
| | - Robert Rau
- Department of Radiology, Kantonsspital Graubünden, Chur, Switzerland
| | | | - Charlotte Zäske
- Department of Radiology, University of Cologne, Cologne, Germany
| | - David Maintz
- Department of Radiology, University of Cologne, Cologne, Germany
| | - Stefan Haneder
- Department of Radiology, University of Cologne, Cologne, Germany
| | | | | | - Florian Siedek
- Department of Radiology, University of Cologne, Cologne, Germany
| | | |
Collapse
|
31
|
Ding J, Duan Y, Zhuo Z, Yuan Y, Zhang G, Song Q, Gao B, Zhang B, Wang M, Yang L, Hou Y, Yuan J, Feng C, Wang J, Lin L, Liu Y. Acceleration of Brain TOF-MRA with Compressed Sensitivity Encoding: A Multicenter Clinical Study. AJNR Am J Neuroradiol 2021; 42:1208-1215. [PMID: 33858820 DOI: 10.3174/ajnr.a7091] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Accepted: 01/10/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND PURPOSE The clinical practice of three-dimensional TOF-MRA, despite its capability in brain artery assessment, has been hampered by the relatively long scan time, while recent developments in fast imaging techniques with random undersampling has shed light on an improved balance between image quality and imaging speed. Our aim was to evaluate the effectiveness of TOF-MRA accelerated by compressed sensitivity encoding and to identify the optimal acceleration factors for routine clinical use. MATERIALS AND METHODS One hundred subjects, enrolled at 5 centers, underwent 8 brain TOF-MRA sequences: 5 sequences using compressed sensitivity encoding with acceleration factors of 2, 4, 6, 8, and 10 (CS2, CS4, CS6, CS8, and CS10), 2 using sensitivity encoding with factors of 2 and 4 (SF2 and SF4), and 1 without acceleration as a reference sequence (RS). Five large arteries, 6 medium arteries, and 6 small arteries were evaluated quantitatively (reconstructed signal intensity, structural similarity, contrast ratio) and qualitatively (scores on arteries, artifacts, overall image quality, and diagnostic confidence for aneurysm and stenosis). Comparisons were performed among the 8 sequences. RESULTS The quantitative measurements showed that the reconstructed signal intensities of the assessed arteries and the structural similarity consistently decreased as the compressed sensitivity encoding acceleration factor increased, and no significant difference was found for the contrast ratios in pair-wise comparisons among SF2, CS2, and CS4. Qualitative evaluations showed no significant difference in pair-wise comparisons among RS, SF2, and CS2 (P > .05). The visualization of all the assessed arteries was acceptable for CS2 and CS4, while 2 small arteries in images of CS6 were not reliably displayed, and the visualization of large arteries was acceptable in images of CS8 and CS10. CONCLUSIONS CS4 is recommended for routine brain TOF-MRA with balanced image quality and acquisition time; CS6, for examinations when small arteries are not evaluated; and CS10, for fast visualization of large arteries.
Collapse
Affiliation(s)
- J Ding
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Y Duan
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Z Zhuo
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Y Yuan
- Department of Radiology (Y.Y., G.Z.), Beijing Royal Integrative Medicine Hospital, Beijing, China
| | - G Zhang
- Department of Radiology (Y.Y., G.Z.), Beijing Royal Integrative Medicine Hospital, Beijing, China
| | - Q Song
- Department of Radiology (Q.S., B.G.), the First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - B Gao
- Department of Radiology (Q.S., B.G.), the First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - B Zhang
- Department of Radiology (B.Z., M.W.), The Affiliated Drum Tower Hospital of Nanjing University Medical School, Jiangsu, China
| | - M Wang
- Department of Radiology (B.Z., M.W.), The Affiliated Drum Tower Hospital of Nanjing University Medical School, Jiangsu, China
| | - L Yang
- Department of Radiology (L.Y., Y.H.), Shengjing Hospital of China Medical University, Shenyang, China
| | - Y Hou
- Department of Radiology (L.Y., Y.H.), Shengjing Hospital of China Medical University, Shenyang, China
| | - J Yuan
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - C Feng
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - J Wang
- Philips Healthcare (J.W., L.L.), Beijing, P.R. China
| | - L Lin
- Philips Healthcare (J.W., L.L.), Beijing, P.R. China
| | - Y Liu
- From the Department of Radiology (J.D., Y.D., Z.Z., J.Y., C.F., Y.L.), Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
32
|
Fritz J, Guggenberger R, Grande FD. Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques. AJR Am J Roentgenol 2021; 216:718-33. [DOI: 10.2214/ajr.20.22902] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
33
|
Endler CHJ, Faron A, Isaak A, Katemann C, Mesropyan N, Kupczyk PA, Pieper CC, Kuetting D, Hadizadeh DR, Attenberger UI, Luetkens JA. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences. ROFO-FORTSCHR RONTG 2021; 193:813-821. [PMID: 33535259 DOI: 10.1055/a-1337-3351] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
PURPOSE Compressed sensing (CS) is a method to accelerate MRI acquisition by acquiring less data through undersampling of k-space. In this prospective study we aimed to evaluate whether a three-dimensional (3D) isotropic proton density-weighted fat saturated sequence (PDwFS) with CS can replace conventional multidirectional two-dimensional (2D) sequences at 1.5 Tesla. MATERIALS AND METHODS 20 patients (45.2 ± 20.2 years; 10 women) with suspected internal knee damage received a 3D PDwFS with CS acceleration factor 8 (acquisition time: 4:11 min) in addition to standard three-plane 2D PDwFS sequences (acquisition time: 4:05 min + 3:03 min + 4:46 min = 11:54 min) at 1.5 Tesla. Scores for homogeneity of fat saturation, image sharpness, and artifacts were rated by two board-certified radiologists on the basis of 5-point Likert scales. Based on these ratings, an overall image quality score was generated. Additionally, quantitative contrast ratios for the menisci (MEN), the anterior (ACL) and the posterior cruciate ligament (PCL) in comparison with the popliteus muscle were calculated. RESULTS The overall image quality was rated superior in 3D PDwFS compared to 2D PDwFS sequences (14.45 ± 0.83 vs. 12.85 ± 0.99; p < 0.01), particularly due to fewer artifacts (4.65 ± 0.67 vs. 3.65 ± 0.49; p < 0.01) and a more homogeneous fat saturation (4.95 ± 0.22 vs. 4.55 ± 0.51; p < 0.01). Scores for image sharpness were comparable (4.80 ± 0.41 vs. 4.65 ± 0.49; p = 0.30). Quantitative contrast ratios for all measured structures were superior in 3D PDwFS (MEN: p < 0.05; ACL: p = 0.06; PCL: p = 0.33). In one case a meniscal tear was only diagnosed using multiplanar reformation of 3D PDwFS, but it would have been missed on standard multiplanar 2D sequences. CONCLUSION An isotropic fat-saturated 3D PD sequence with CS enables fast and high-quality 3D imaging of the knee joint at 1.5 T and may replace conventional multiplanar 2D sequences. Besides faster image acquisition, the 3D sequence provides advantages in small structure imaging by multiplanar reformation. KEY POINTS · 3D PDwFS with compressed sensing enables knee imaging that is three times faster compared to multiplanar 2D sequences. · 3D PDwFS with compressed sensing provides high-quality knee imaging at 1.5 T. · Isotropic 3D sequences provide advantages in small structure imaging by using multiplanar reformations. CITATION FORMAT · Endler CH, Faron A, Isaak A et al. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences. Fortschr Röntgenstr 2021; 193: 813 - 821.
Collapse
Affiliation(s)
- Christoph H-J Endler
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Anton Faron
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | | | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Patrick A Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Dariusch R Hadizadeh
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| |
Collapse
|
34
|
Pfeifer C, Attenberger U, Schoenberg SO, Riffel P, Uder M, Hinterwimmer S, Strecker R, Adamietz B. [Diagnostic value of a 3D-SPACE-sequence with compressed sensing technology for the knee joint]. Radiologe 2021; 61:203-12. [PMID: 33346870 DOI: 10.1007/s00117-020-00788-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/02/2020] [Indexed: 12/22/2022]
Abstract
BACKROUND SPACE (3D fast spin echo acquisition) sequences require long scan times for three-dimensional assessment of acute injury of the knee joint and are flawed due to geometric blurring. Their implementation into routine diagnostic imaging was not feasible until recently. OBJECTIVES By comparing conventional MRI (magnetic resonance imaging) sequences to 3D (three-dimensional) sequences, it was investigated whether the compressed sensing (CS) technique is inferior to the established 2D sequences with shorter examination times. MATERIALS AND METHODS A total of 109 patients (age range 18-50 years) with knee injury were examined by MRI between April 2017 and May 2018. The inter- and intraobserver concordance of two blinded readers were assessed. Consensus was achieved in case of discrepancies. Descriptive analyses of absolute and relative frequency and distribution were tested by Fisher's exact test concerning differences between CS-SPACE and standard proton density fat suppressed imaging. RESULTS Interoberserver concordance (IC) of conventional sequences before/after consensus amounted to 58.8/68.1% (medial meniscus, MM), 68.8/88.7% (lateral meniscus, LM) 88.9/97.2% (anterior cruciate ligament, ACL), 99/100% (posterior cruciate ligament, PCL), 88.9/97.2% (collateral ligament, CL) and chondral injury (CI) 1-2: 64.2%, CI-3: 77% and CI-4: 76%. The IC of CS-SPACE amounted before/after consensus of MM to 50.4/77%, LM 68.8/88%, ACL 89.9/94.5%, PCL 97.2/99.0%, CL 92.6/96.3%. IC of CI was evaluated without consensus and amounted to 65.1% (CI 1-2), 66% (CI 3) and 81.6% (CI 4). CONCLUSIONS Injuries of ACL, PCL and CL have excellent IC between 3D and 2D sequences. Excellent IC could be found in CI grade 3 and 4 when using 2D sequences and CI grade 4 utilizing CS-SPACE. Our results indicate that CS-SPACE is useful in diagnosing acute knee injuries.
Collapse
|
35
|
Li G, Wu D, Xu Z, Zuo X, Li X, Chang S, Dai Y. Evaluation of an accelerated 3D modulated flip-angle technique in refocused imaging with an extended echo-train sequence with compressed sensing for imaging of the knee: comparison with routine 2D MRI sequences. Clin Radiol 2020; 76:158.e13-158.e18. [PMID: 33250173 DOI: 10.1016/j.crad.2020.10.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Accepted: 10/28/2020] [Indexed: 11/24/2022]
Abstract
AIM To accelerate the acquisition of high-resolution magnetic resonance imaging (MRI) by using the three-dimensional (3D) matrix sequence with compressed sensing and to compare it with conventional two-dimensional (2D) proton-density (PD) and fast spin-echo (FSE) sequences. MATERIALS AND METHODS 3D matrix, 2D FSE, and PD sequences were acquired from 68 participants using 3 T magnetic resonance imaging (MRI). Two radiologists scored image quality independently on a four-point scale. The structural similarity index (SSIM), and signal- (SNRs) and contrast-to-noise ratios (CNRs) of different anatomical structures of the knee were assessed and compared between sequences using Wilcoxon signed-rank tests and Cohen's kappa. RESULTS The median acquisition time reduction was 44.5%. There was a substantial to perfect agreement for the rating between the 3D matrix FSE and 2D FSE or PD sequences when evaluating cartilage, subchondral bone, and ligaments (κ=0.783-872, p>0.05). The mean SSIM values between the 3D matrix FSE and 2D FSE, and between the 3D matrix PD and 2D PD sequences was 0.994 and 0.971, respectively, which are acceptable. No significant differences were found in SNR between the 3D matrix FSE and 2D FSE, and between the 3D matrix PD and 2D PD sequences, even though the SNR appeared to be higher on routine 2D sequences. The CNR of subchondral bone-meniscus, subchondral bone-joint fluid, and meniscus-joint fluid did not differentiate significantly between the 3D matrix sequence and routine 2D sequences. CONCLUSIONS 3D matrix reduced the acquisition time in routine clinical knee MRI without the loss in image quality, SNR, and CNR.
Collapse
Affiliation(s)
- G Li
- Department of Radiology, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - D Wu
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronics Science, East China Normal University, Shanghai, China
| | - Z Xu
- Xinzhuang Community Health Center, Shanghai, China
| | - X Zuo
- Department of Radiology, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - X Li
- Department of Radiology, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - S Chang
- Department of Radiology, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China.
| | - Y Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| |
Collapse
|
36
|
Iuga AI, Abdullayev N, Weiss K, Haneder S, Brüggemann-Bratke L, Maintz D, Rau R, Bratke G. Accelerated MRI of the knee. Quality and efficiency of compressed sensing. Eur J Radiol 2020; 132:109273. [DOI: 10.1016/j.ejrad.2020.109273] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 08/26/2020] [Accepted: 09/06/2020] [Indexed: 10/23/2022]
|
37
|
Subhas N, Li H, Yang M, Winalski CS, Polster J, Obuchowski N, Mamoto K, Liu R, Zhang C, Huang P, Gaire SK, Liang D, Shen B, Li X, Ying L. Diagnostic interchangeability of deep convolutional neural networks reconstructed knee MR images: preliminary experience. Quant Imaging Med Surg 2020; 10:1748-1762. [PMID: 32879854 DOI: 10.21037/qims-20-664] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Background MRI acceleration using deep learning (DL) convolutional neural networks (CNNs) is a novel technique with great promise. Increasing the number of convolutional layers may allow for more accurate image reconstruction. Studies on evaluating the diagnostic interchangeability of DL reconstructed knee magnetic resonance (MR) images are scarce. The purpose of this study was to develop a deep CNN (DCNN) with an optimal number of layers for accelerating knee magnetic resonance imaging (MRI) acquisition by 6-fold and to test the diagnostic interchangeability and image quality of nonaccelerated images versus images reconstructed with a 15-layer DCNN or 3-layer CNN. Methods For the feasibility portion of this study, 10 patients were randomly selected from the Osteoarthritis Initiative (OAI) cohort. For the interchangeability portion of the study, 40 patients were randomly selected from the OAI cohort. Three readers assessed meniscal and anterior cruciate ligament (ACL) tears and cartilage defects using DCNN, CNN, and nonaccelerated images. Image quality was subjectively graded as nondiagnostic, poor, acceptable, or excellent. Interchangeability was tested by comparing the frequency of agreement when readers used both accelerated and nonaccelerated images to frequency of agreement when readers only used nonaccelerated images. A noninferiority margin of 0.10 was used to ensure type I error ≤5% and power ≥80%. A logistic regression model using generalized estimating equations was used to compare proportions; 95% confidence intervals (CIs) were constructed. Results DCNN and CNN images were interchangeable with nonaccelerated images for all structures, with excess disagreement values ranging from -2.5% [95% CI: (-6.1, 1.1)] to 3.0% [95% CI: (-0.1, 6.1)]. The quality of DCNN images was graded higher than that of CNN images but less than that of nonaccelerated images [excellent/acceptable quality: DCNN, 95% of cases (114/120); CNN, 60% (72/120); nonaccelerated, 97.5% (117/120)]. Conclusions Six-fold accelerated knee images reconstructed with a DL technique are diagnostically interchangeable with nonaccelerated images and have acceptable image quality when using a 15-layer CNN.
Collapse
Affiliation(s)
- Naveen Subhas
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Hongyu Li
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| | - Mingrui Yang
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Carl S Winalski
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Joshua Polster
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Nancy Obuchowski
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Quantitative Health Sciences, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kenji Mamoto
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Ruiying Liu
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| | - Chaoyi Zhang
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| | - Peizhou Huang
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| | - Sunil Kumar Gaire
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Medical AI Research Center, SIAT, CAS, Shenzhen, China
| | - Bowen Shen
- Department of Computer Science, Virginia Tech, Blacksburg, VA, USA
| | - Xiaojuan Li
- Program of Advanced Musculoskeletal Imaging (PAMI), Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, Cleveland, OH, USA.,Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Leslie Ying
- Department of Biomedical Engineering, Department of Electrical Engineering, University at Buffalo, the State University of New York, Buffalo, NY, USA
| |
Collapse
|
38
|
Takumi K, Nagano H, Nakanosono R, Kumagae Y, Fukukura Y, Yoshiura T. Combined signal averaging and compressed sensing: impact on quality of contrast-enhanced fat-suppressed 3D turbo field-echo imaging for pharyngolaryngeal squamous cell carcinoma. Neuroradiology 2020; 62:1293-1299. [PMID: 32577772 DOI: 10.1007/s00234-020-02480-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 06/11/2020] [Indexed: 01/13/2023]
Abstract
PURPOSE To determine whether combined signal averaging and compressed sensing (CS averaging) improves the image quality of contrast-enhanced fat-suppressed T1-weighted three-dimensional turbo field-echo (FS T1W 3D-TFE) for evaluation of pharyngolaryngeal squamous cell carcinoma (PLSCC). METHODS This retrospective study included 27 patients with PLSCC. In all patients, contrast-enhanced FS T1W 3D-TFE imaging with CS averaging (number of excitations, 7) and that without CS averaging (number of excitations, 1) were obtained during the same acquisition time. Overall image quality, mucosal enhancement, vessel clarity, motion artifact, lesion conspicuity, and lesion edge sharpness were qualitatively evaluated using a 5-point scale. Images with and without CS averaging were compared using the Wilcoxon signed-rank test. Signal-to-noise ratio (SNR) of the lesion and the muscle structure were compared between the two imaging methods using a paired t-test. RESULTS Compared with the images without CS averaging, those with CS averaging showed significantly better overall image quality (p = 0.002), mucosal enhancement (p = 0.009), vessel clarity (p = 0.003), muscle edge clarity (p = 0.002), lesion conspicuity (p = 0.002), and lesion edge sharpness (p = 0.001); and less motion artifact (p < 0.001). The SNRs of the lesion and of the muscle structure were significantly higher for images with CS averaging than those without CS averaging (p < 0.001). CONCLUSION CS averaging improves the image quality of contrast-enhanced FS T1W 3D-TFE MR images for evaluation of PLSCC without requiring additional acquisition time.
Collapse
Affiliation(s)
- Koji Takumi
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan.
| | - Hiroaki Nagano
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Ryota Nakanosono
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Yuichi Kumagae
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Yoshihiko Fukukura
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| | - Takashi Yoshiura
- Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City, 890-8544, Japan
| |
Collapse
|
39
|
Mann JR, Wieschhoff GG, Tai R, Wrobel WC, Shah N, Mandell JC. Tibial bone stress injury: diagnostic performance and inter-reader agreement of an abbreviated 5-min magnetic resonance protocol. Skeletal Radiol 2020; 49:425-34. [PMID: 31420694 DOI: 10.1007/s00256-019-03297-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 07/08/2019] [Accepted: 08/05/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To compare the diagnostic performance and inter-reader agreement of an abbreviated (5 min) MR protocol compared to a complete (25 min) protocol, for evaluation of suspected tibial bone stress injury. MATERIALS AND METHODS This IRB-approved retrospective study consisted of 95 consecutive MR examinations in 88 patients with suspected tibial bone stress injury. Three musculoskeletal radiologists independently classified all examinations utilizing both an abbreviated protocol consisting only of axial T2-weighted images with fat suppression, and after a washout period again classified the complete examinations. Accuracy was calculated as proportion of cases classified exactly, within 1 grade, within 2 grades, and also utilizing a simplified "clinically relevant" classification combining grades 2, 3, and 4A into a single group. Significance testing was performed with the chi-test, and a post-hoc power analysis was performed. Inter-reader agreement was calculated with Kendall's coefficient of concordance, with significance testing performed utilizing the z-test after bootstrapping to obtain the standard error. RESULTS AND CONCLUSIONS There was no significant difference in accuracy of grading tibial bone stress injuries between complete and abbreviated examinations. For complete exams, pooled exact accuracy was 47.8%; accuracy within 1 grade was 82.8%; and accuracy within 2 grades was 96.1%. For the abbreviated protocol, corresponding accuracies were 50.2, 82.0, and 93.9%. With the "clinically relevant" simplified classification, accuracy was 58.6% for complete exams and 64.2% for abbreviated exams. There was no significant difference in inter-reader agreement, with substantial agreement demonstrated for both complete (Kendall coefficient of concordance 0.805) and abbreviated examinations (coefficient of 0.767).
Collapse
|
40
|
Roemer FW, Collins J, Kwoh CK, Hannon MJ, Neogi T, Felson DT, Hunter DJ, Lynch JA, Guermazi A. MRI-based screening for structural definition of eligibility in clinical DMOAD trials: Rapid OsteoArthritis MRI Eligibility Score (ROAMES). Osteoarthritis Cartilage 2020; 28:71-81. [PMID: 31513920 PMCID: PMC7235947 DOI: 10.1016/j.joca.2019.08.005] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 08/06/2019] [Accepted: 08/28/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE Our aim was to introduce a simplified MRI instrument, Rapid OsteoArthritis MRI Eligibility Score (ROAMES), for defining structural eligibility of patients for inclusion in disease-modifying osteoarthritis drug trials using a tri-compartmental anatomic approach that enables stratification of knees into different structural phenotypes and includes diagnoses of exclusion. We also aimed to define overlap between phenotypes and determine reliability. METHODS 50 knees from the Foundation for National Institutes of Health Osteoarthritis Biomarkers study, a nested case-control study within the Osteoarthritis Initiative, were selected within pre-defined definitions of phenotypes as either inflammatory, subchondral bone, meniscus/cartilage, atrophic or hypertrophic. A focused scoring instrument was developed covering cartilage, meniscal damage, inflammation and osteophytes. Diagnoses of exclusion were meniscal root tears, osteonecrosis, subchondral insufficiency fracture, tumors, malignant marrow infiltration and acute traumatic changes. Reliability was determined using weighted kappa statistics. Descriptive statistics were used for determining concordance between the a priori phenotypic definition and ROAMES and overlap between phenotypes. RESULTS ROAMES identified 43 of 50 (86%) pre-defined phenotypes correctly. Of the 50 participants, 27 (54%) had no additional phenotypes other than the pre-defined phenotype. 18 (36%) had one and 5 (10%) had two additional phenotypes. None had three or four additional phenotypes. All features of ROAMES showed almost perfect agreement. One case with osteonecrosis and one with a tumor were detected. CONCLUSIONS ROAMES is able to screen and stratify potentially eligible knees into different structural phenotypes and record relevant diagnoses of exclusion. Reliability of the instrument showed almost perfect agreement.
Collapse
Affiliation(s)
- Frank W. Roemer
- Quantitative Imaging Center, Department of Radiology, Boston University School of Medicine, FGH Building, 4th floor, 820 Harrison Avenue, Boston, MA 02118, USA,Department of Radiology, Friedrich-Alexander University Erlangen-Nürnberg (FAU) and Universitätsklinikum Erlangen, Erlangen, Germany, Maximiliansplatz 3, 91054 Erlangen, Germany
| | - Jamie Collins
- Orthopaedics and Arthritis Center of Outcomes Research, Brigham and Women’s Hospital, Harvard Medical, School, 75 Francis Street, BTM Suite 5016 Boston, MA 02115 Boston, Massachusetts
| | - C. Kent Kwoh
- University of Arizona Arthritis Center & University of Arizona College of Medicine, 1501 N Campbell Ave, Tucson, AZ 85724, USA
| | - Michael J. Hannon
- Pinney Associates, 201 N Craig St # 320, Pittsburgh, PA 15213, USA & Division of Rheumatology and Clinical Immunology, University of Pittsburgh School of Medicine, S700 Biomedical Science Tower, 3500 Terrace Street, Pittsburgh, PA 15261, USA (former affiliation at time of study)
| | - Tuhina Neogi
- Boston University School of Medicine, Section of Rheumatology, 650 Albany Street, Suite X-20, Boston, MA, 02118, USA
| | - David T. Felson
- Boston University School of Medicine, Section of Rheumatology, 650 Albany Street, Suite X-20, Boston, MA, 02118, USA
| | - David J. Hunter
- Department of Rheumatology, Royal North Shore Hospital and Institute of Bone and Joint Research, Kolling Institute, University of Sydney, Pacific Hwy, St Leonards, NSW 2065, Australia
| | - John A. Lynch
- Department of Epidemiology and Biostatistics, University of California San Francisco, 550 16th St, San Francisco, CA 94158, USA
| | - Ali Guermazi
- Quantitative Imaging Center, Department of Radiology, Boston University School of Medicine, FGH Building, 4th floor, 820 Harrison Avenue, Boston, MA 02118, USA
| |
Collapse
|
41
|
Matcuk GR, Gross JS, Fields BKK, Cen S. Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time. Magn Reson Med Sci 2019; 19:254-258. [PMID: 31548480 PMCID: PMC7553806 DOI: 10.2463/mrms.tn.2019-0095] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
We compared 3 Tesla (3T) compressed sensing (CS)-MRI of different pulse sequences with various acceleration factors to standard fast spin-echo (FSE) sequences in terms of time, quality, and inter-reader agreement. Each sequence was qualitatively ranked and then qualitatively scored for blurring, artifact, low contrast detection, noise pattern, signal-to-noise ratio, and overall quality. The CS-MRI sequences demonstrated very good overall quality compared with routine FSE sequences with overall good inter-reader agreement.
Collapse
Affiliation(s)
| | - Jordan S Gross
- Department of Radiology, University of Southern California
| | | | - Steven Cen
- Department of Radiology, University of Southern California
| |
Collapse
|
42
|
Sartoretti T, Sartoretti E, Wyss M, Schwenk Á, van Smoorenburg L, Eichenberger B, Najafi A, Binkert C, Becker AS, Sartoretti-Schefer S. Compressed SENSE accelerated 3D T1w black blood turbo spin echo versus 2D T1w turbo spin echo sequence in pituitary magnetic resonance imaging. Eur J Radiol 2019; 120:108667. [PMID: 31550639 DOI: 10.1016/j.ejrad.2019.108667] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 08/23/2019] [Accepted: 09/08/2019] [Indexed: 12/21/2022]
Abstract
PURPOSE To compare image quality between a 2D T1w turbo spin echo (TSE) sequence and a Compressed SENSE accelerated 3D T1w black blood TSE sequence (equipped with a black blood prepulse for blood signal suppression) in pre- and postcontrast imaging of the pituitary and to assess scan time reductions. METHODS AND MATERIALS For this retrospective study, 56 patients underwent pituitary MR imaging at 3T. 28 patients were scanned with the 2D- and 28 patients with the accelerated 3D sequence. Two board certified neuroradiologists independently evaluated 13 qualitative image features (12 features on postcontrast- and 1 feature on precontrast images).SNR and CNR measurements were obtained. Interreader agreement was assessed with the intraclass correlation coefficient while differences in scores were assessed with exact Wilcoxon rank sum tests. RESULTS The interreader agreement ranged from fair (visibility of the ophthalmic nerve, ICC = 0.57) to excellent (presence and severity of pulsation artefacts, ICC = 0.97). The Compressed SENSE accelerated 3D sequence outperformed the 2D sequence in terms of "overall image quality" (median: 4 versus 3, p = 0.04) and "presence and severity of pulsation artefacts" (median: 0 versus 1, p < 0.001). There were no significant differences in any other qualitative and quantitative (SNR, CNR) image quality features. Scan time was reduced by 03:53 min (33.1%) by replacing the 2D with the 3D sequence. CONCLUSION The Compressed SENSE accelerated 3D T1w black blood TSE sequence is a reliable alternative for the standard 2D sequence in pituitary imaging. The black blood prepulse may aid in suppression of pulsation artefacts.
Collapse
Affiliation(s)
- Thomas Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Elisabeth Sartoretti
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Michael Wyss
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland; Philips Healthsystems, Zürich, Switzerland.
| | - Árpád Schwenk
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Luuk van Smoorenburg
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Barbara Eichenberger
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Arash Najafi
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Christoph Binkert
- Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401, Winterthur, Switzerland.
| | - Anton S Becker
- Institute of Diagnostic and Interventional Radiology, University Hospital Zürich, University of Zürich, Raemistrasse 100, CH-8091, Zürich, Switzerland; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
| | | |
Collapse
|
43
|
Roemer FW, Kwoh CK, Hayashi D, Felson DT, Guermazi A. The role of radiography and MRI for eligibility assessment in DMOAD trials of knee OA. Nat Rev Rheumatol 2018; 14:372-80. [PMID: 29752462 DOI: 10.1038/s41584-018-0010-z] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Currently, no disease-modifying osteoarthritis drugs (DMOADs) have been approved. Past clinical trials have failed for several reasons, including the commonly applied definition of eligibility based on radiographic assessment of joint structure. In the context of precision medicine, finding the appropriate patient for a specific treatment approach will be of increasing relevance. Phenotypic stratification by use of imaging at the time of determining eligibility for clinical trials will be paramount and cannot be achieved using radiography alone. Furthermore, identification of joints at high risk of rapid progression of osteoarthritis is needed in order to enable a more efficient DMOAD trial design. In addition, joints at high risk of collapse need to be excluded at screening. The use of MRI might offer advantages over radiography in this context. Technological advances and simplified image assessment address many of the commonly perceived barriers to the application of MRI to assessment of eligibility for DMOAD clinical trials.
Collapse
|
44
|
Glaser C, Heuck A, Horng A. Update: Klinische Knorpelbildgebung – Teil 1. Radiologe 2019; 59:692-699. [DOI: 10.1007/s00117-019-0561-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
45
|
Delattre BMA, Boudabbous S, Hansen C, Neroladaki A, Hachulla AL, Vargas MI. Compressed sensing MRI of different organs: ready for clinical daily practice? Eur Radiol 2019; 30:308-319. [PMID: 31264014 DOI: 10.1007/s00330-019-06319-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 05/28/2019] [Accepted: 06/11/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS • Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.
Collapse
Affiliation(s)
| | - Sana Boudabbous
- Division of Radiology, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1211, Geneva 14, Switzerland
| | - Catrina Hansen
- Division of Radiology, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1211, Geneva 14, Switzerland
| | - Angeliki Neroladaki
- Division of Radiology, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1211, Geneva 14, Switzerland
| | - Anne-Lise Hachulla
- Division of Radiology, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1211, Geneva 14, Switzerland
| | - Maria Isabel Vargas
- Division of Neuroradiology, Geneva University Hospitals , Geneva, Switzerland
| |
Collapse
|
46
|
Yi J, Lee YH, Hahn S, Albakheet SS, Song HT, Suh JS. Fast isotropic volumetric magnetic resonance imaging of the ankle: Acceleration of the three-dimensional fast spin echo sequence using compressed sensing combined with parallel imaging. Eur J Radiol 2019; 112:52-58. [DOI: 10.1016/j.ejrad.2019.01.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 01/05/2019] [Accepted: 01/08/2019] [Indexed: 11/26/2022]
|
47
|
Link TM, Patel R. The need for short MRI examinations: A musculoskeletal perspective. J Magn Reson Imaging 2019; 49:e49-e50. [DOI: 10.1002/jmri.26565] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Accepted: 10/16/2018] [Indexed: 12/26/2022] Open
Affiliation(s)
- Thomas M. Link
- Department of Radiology of Biomedical ImagingUniversity of California San Francisco California USA
| | - Rina Patel
- Department of Radiology of Biomedical ImagingUniversity of California San Francisco California USA
| |
Collapse
|
48
|
Okuchi S, Fushimi Y, Okada T, Yamamoto A, Okada T, Kikuchi T, Yoshida K, Miyamoto S, Togashi K. Visualization of carotid vessel wall and atherosclerotic plaque: T1-SPACE vs. compressed sensing T1-SPACE. Eur Radiol 2019; 29:4114-22. [PMID: 30523455 DOI: 10.1007/s00330-018-5862-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 09/27/2018] [Accepted: 10/25/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To compare visualization of carotid plaques and vessel walls between 3D T1-fast spin echo imaging with conventional SPACE (T1-SPACE) and with a prototype compressed sensing T1-SPACE (CS-T1-SPACE) METHODS: This retrospective study was approved by the institutional review board. Participants comprised 43 patients (36 males, 7 females; mean age, 71 years) who underwent carotid MRI including T1-SPACE and CS-T1-SPACE. The quality of visualization for carotid plaques and vessel walls was evaluated using a 5-point scale, and signal intensity ratios (SRs) of the carotid plaques were measured and normalized to the adjacent sternomastoid muscle. Scores for the quality of visualization were compared between T1-SPACE and CS-T1-SPACE using the Wilcoxon signed-rank test. Statistical differences between SRs of plaques with T1-SPACE and CS-T1-SPACE were also evaluated using the Wilcoxon signed-rank test, and Spearman's correlation coefficient was calculated to investigate correlations. RESULTS Visualization scores were significantly higher for CS-T1-SPACE than for T1-SPACE when evaluating carotid plaques (p = 0.0212) and vessel walls (p < 0.001). The SR of plaques did not differ significantly between T1-SPACE and CS-T1-SPACE (p = 0.5971). Spearman's correlation coefficient was significant (0.884; p < 0.0001). CONCLUSIONS CS-T1-SPACE allowed better visualization scores and sharpness compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. CS-T1-SPACE appears promising as a method for investigating carotid vessel walls, offering better image quality with a shorter acquisition time. KEY POINTS • CS-T1-SPACE allowed better visualization compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. • CS-T1-SPACE offers a promising method for investigating carotid vessel walls due to the better image quality with shorter acquisition time. • Physiological movements such as swallowing, arterial pulsations, and breathing induce motion artifacts in vessel wall imaging, and a shorter acquisition time can reduce artifacts from physiological movements.
Collapse
|
49
|
Bratke G, Rau R, Weiss K, Kabbasch C, Sircar K, Morelli JN, Persigehl T, Maintz D, Giese D, Haneder S. Accelerated MRI of the Lumbar Spine Using Compressed Sensing: Quality and Efficiency. J Magn Reson Imaging 2018; 49:e164-e175. [PMID: 30267462 DOI: 10.1002/jmri.26526] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Decreasing MRI scan time is a key factor to increase patient comfort and compliance as well as the productivity of MRI scanners. PURPOSE/HYPOTHESIS Compressed sensing (CS) should significantly accelerate 3D scans. This study evaluated the clinical application and cost effectiveness of accelerated 3D T2 sequences of the lumbar spine. STUDY TYPE Prospective, cross-sectional, observational. POPULATION Twenty healthy volunteers and 10 patients. FIELD STRENGTH/SEQUENCE A 3D T2 TSE sequence, identical 3D sequences with three different parallel imaging and CS accelerating factors, and 2D TSE sequences as a clinical reference were obtained on a 3T scanner. ASSESSMENT Three readers evaluated the sequences for delineation of anatomical structures and image quality. A quantitative analysis consisting of root mean square error, structural similarity index, signal-to-noise ratio, and contrast-to-noise ratio were performed. The scan times were used to calculate cost differences for each sequence. STATISTICAL TESTS An analysis of variance with repeated measurements and the Friedman test were used to test for potential differences between the sequences. Post-hoc analysis was made with the chi-squared and Tukey-Kramer test. RESULTS CS with factor 4.5 results in unchanged image quality compared to the T2 TSE for volunteers and patients (overall image impression: 4.75 vs. 4.20 [P = 0.73] and 4.90 vs. 4.47 [P = 0.44]). The CS 4.5 scan is 167 seconds (-39%) faster than the 3D and 216.5 seconds (-45%) faster than the 2D sequences. No significant differences was found for the diagnostic certainty in the volunteers and patients between 2D TSE and 3D CS 4.5 (P = 0.89 and P = 0.43). A reduction of scan time to 148 seconds (CS 8) was still rated acceptable for most diagnosis. DATA CONCLUSION CS accelerates the 3D T2 without compromising image quality. The 3D sequences offer comparable diagnostic quality to the clinical 2D standard with less scan time (-45%), potentially increasing the productivity of MRI scanners. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019;49:e164-e175.
Collapse
Affiliation(s)
- Grischa Bratke
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| | - Robert Rau
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| | | | | | - Krishnan Sircar
- Department of Orthopedics, University Hospital Cologne, Cologne, Germany
| | | | | | - David Maintz
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| | - Daniel Giese
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| | - Stefan Haneder
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
50
|
|