López-Larraz E, Escolano C, Robledo-Menéndez A, Morlas L, Alda A, Minguez J. A garment that measures brain activity: proof of concept of an EEG sensor layer fully implemented with smart textiles. Front Hum Neurosci 2023; 17:1135153. [PMID: 37305362 PMCID: PMC10250743 DOI: 10.3389/fnhum.2023.1135153] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 04/20/2023] [Indexed: 06/13/2023] Open
Abstract
This paper presents the first garment capable of measuring brain activity with accuracy comparable to that of state-of-the art dry electroencephalogram (EEG) systems. The main innovation is an EEG sensor layer (i.e., the electrodes, the signal transmission, and the cap support) made entirely of threads, fabrics, and smart textiles, eliminating the need for metal or plastic materials. The garment is connected to a mobile EEG amplifier to complete the measurement system. As a first proof of concept, the new EEG system (Garment-EEG) was characterized with respect to a state-of-the-art Ag/AgCl dry-EEG system (Dry-EEG) over the forehead area of healthy participants in terms of: (1) skin-electrode impedance; (2) EEG activity; (3) artifacts; and (4) user ergonomics and comfort. The results show that the Garment-EEG system provides comparable recordings to Dry-EEG, but it is more susceptible to artifacts under adverse recording conditions due to poorer contact impedances. The textile-based sensor layer offers superior ergonomics and comfort compared to its metal-based counterpart. We provide the datasets recorded with Garment-EEG and Dry-EEG systems, making available the first open-access dataset of an EEG sensor layer built exclusively with textile materials. Achieving user acceptance is an obstacle in the field of neurotechnology. The introduction of EEG systems encapsulated in wearables has the potential to democratize neurotechnology and non-invasive brain-computer interfaces, as they are naturally accepted by people in their daily lives. Furthermore, supporting the EEG implementation in the textile industry may result in lower cost and less-polluting manufacturing processes compared to metal and plastic industries.
Collapse
|
2
|
Shivaraja TR, Remli R, Kamal N, Wan Zaidi WA, Chellappan K. Assessment of a 16-Channel Ambulatory Dry Electrode EEG for Remote Monitoring. Sensors (Basel) 2023; 23:3654. [PMID: 37050713 PMCID: PMC10098757 DOI: 10.3390/s23073654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
Ambulatory EEGs began emerging in the healthcare industry over the years, setting a new norm for long-term monitoring services. The present devices in the market are neither meant for remote monitoring due to their technical complexity nor for meeting clinical setting needs in epilepsy patient monitoring. In this paper, we propose an ambulatory EEG device, OptiEEG, that has low setup complexity, for the remote EEG monitoring of epilepsy patients. OptiEEG's signal quality was compared with a gold standard clinical device, Natus. The experiment between OptiEEG and Natus included three different tests: eye open/close (EOC); hyperventilation (HV); and photic stimulation (PS). Statistical and wavelet analysis of retrieved data were presented when evaluating the performance of OptiEEG. The SNR and PSNR of OptiEEG were slightly lower than Natus, but within an acceptable bound. The standard deviations of MSE for both devices were almost in a similar range for the three tests. The frequency band energy analysis is consistent between the two devices. A rhythmic slowdown of theta and delta was observed in HV, whereas photic driving was observed during PS in both devices. The results validated the performance of OptiEEG as an acceptable EEG device for remote monitoring away from clinical environments.
Collapse
Affiliation(s)
- Theeban Raj Shivaraja
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| | - Rabani Remli
- Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
- Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
| | - Noorfazila Kamal
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| | - Wan Asyraf Wan Zaidi
- Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
- Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
| | - Kalaivani Chellappan
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| |
Collapse
|
3
|
Torkamani-Azar M, Lee A, Bednarik R. Methods and Measures for Mental Stress Assessment in Surgery: A Systematic Review of 20 Years of Literature. IEEE J Biomed Health Inform 2022; 26:4436-4449. [PMID: 35696473 DOI: 10.1109/jbhi.2022.3182869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Real-time mental stress monitoring from surgeons and surgical staff in operating rooms may reduce surgical injuries, improve performance and quality of medical care, and accelerate implementation of stress-management strategies. Motivated by the increase in usage of objective and subjective metrics for cognitive monitoring and by the gap in reviews of experimental design setups and data analytics, a systematic review of 71 studies on mental stress and workload measurement in surgical settings, published in 2001-2020, is presented. Almost 61% of selected papers used both objective and subjective measures, followed by 25% that only administered subjective tools - mostly consisting of validated instruments and customized surveys. An overall increase in the total number of publications on intraoperative stress assessment was observed from mid-2010 s along with a momentum in the use of both subjective and real-time objective measures. Cardiac activity, including heart-rate variability metrics, stress hormones, and eye-tracking metrics were the most frequently and electroencephalography (EEG) was the least frequently used objective measures. Around 40% of selected papers collected at least two objective measures, 41% used wearable devices, 23% performed synchronization and annotation, and 76% conducted baseline or multi-point data acquisition. Furthermore, 93% used a variety of statistical techniques, 14% applied regression models, and only one study released a public, anonymized dataset. This review of data modalities, experimental setups, and analysis techniques for intraoperative stress monitoring highlights the initiatives of surgical data science and motivates research on computational techniques for mental and surgical skills assessment and cognition-guided surgery.
Collapse
|
4
|
Branco LRF, Ehteshami A, Azgomi HF, Faghih RT. Closed-Loop Tracking and Regulation of Emotional Valence State From Facial Electromyogram Measurements. Front Comput Neurosci 2022; 16:747735. [PMID: 35399915 PMCID: PMC8990324 DOI: 10.3389/fncom.2022.747735] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 02/21/2022] [Indexed: 11/25/2022] Open
Abstract
Affective studies provide essential insights to address emotion recognition and tracking. In traditional open-loop structures, a lack of knowledge about the internal emotional state makes the system incapable of adjusting stimuli parameters and automatically responding to changes in the brain. To address this issue, we propose to use facial electromyogram measurements as biomarkers to infer the internal hidden brain state as feedback to close the loop. In this research, we develop a systematic way to track and control emotional valence, which codes emotions as being pleasant or obstructive. Hence, we conduct a simulation study by modeling and tracking the subject's emotional valence dynamics using state-space approaches. We employ Bayesian filtering to estimate the person-specific model parameters along with the hidden valence state, using continuous and binary features extracted from experimental electromyogram measurements. Moreover, we utilize a mixed-filter estimator to infer the secluded brain state in a real-time simulation environment. We close the loop with a fuzzy logic controller in two categories of regulation: inhibition and excitation. By designing a control action, we aim to automatically reflect any required adjustments within the simulation and reach the desired emotional state levels. Final results demonstrate that, by making use of physiological data, the proposed controller could effectively regulate the estimated valence state. Ultimately, we envision future outcomes of this research to support alternative forms of self-therapy by using wearable machine interface architectures capable of mitigating periods of pervasive emotions and maintaining daily well-being and welfare.
Collapse
Affiliation(s)
- Luciano R. F. Branco
- Department of Electrical and Computer Engineering, University of Houston, Houston, TX, United States
| | - Arian Ehteshami
- Department of Electrical and Computer Engineering, University of Houston, Houston, TX, United States
| | - Hamid Fekri Azgomi
- Department of Electrical and Computer Engineering, University of Houston, Houston, TX, United States
- Department of Neurological Surgery, University of California, San Francisco, San Francisco, CA, United States
| | - Rose T. Faghih
- Department of Electrical and Computer Engineering, University of Houston, Houston, TX, United States
- Department of Biomedical Engineering, New York University, New York, NY, United States
| |
Collapse
|
5
|
Cannard C, Wahbeh H, Delorme A. Electroencephalography Correlates of Well-Being Using a Low-Cost Wearable System. Front Hum Neurosci 2021; 15:745135. [PMID: 35002651 PMCID: PMC8740323 DOI: 10.3389/fnhum.2021.745135] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 11/15/2021] [Indexed: 12/02/2022] Open
Abstract
Electroencephalography (EEG) alpha asymmetry is thought to reflect crucial brain processes underlying executive control, motivation, and affect. It has been widely used in psychopathology and, more recently, in novel neuromodulation studies. However, inconsistencies remain in the field due to the lack of consensus in methodological approaches employed and the recurrent use of small samples. Wearable technologies ease the collection of large and diversified EEG datasets that better reflect the general population, allow longitudinal monitoring of individuals, and facilitate real-world experience sampling. We tested the feasibility of using a low-cost wearable headset to collect a relatively large EEG database (N = 230, 22-80 years old, 64.3% female), and an open-source automatic method to preprocess it. We then examined associations between well-being levels and the alpha center of gravity (CoG) as well as trait EEG asymmetries, in the frontal and temporoparietal (TP) areas. Robust linear regression models did not reveal an association between well-being and alpha (8-13 Hz) asymmetry in the frontal regions, nor with the CoG. However, well-being was associated with alpha asymmetry in the TP areas (i.e., corresponding to relatively less left than right TP cortical activity as well-being levels increased). This effect was driven by oscillatory activity in lower alpha frequencies (8-10.5 Hz), reinforcing the importance of dissociating sub-components of the alpha band when investigating alpha asymmetries. Age was correlated with both well-being and alpha asymmetry scores, but gender was not. Finally, EEG asymmetries in the other frequency bands were not associated with well-being, supporting the specific role of alpha asymmetries with the brain mechanisms underlying well-being levels. Interpretations, limitations, and recommendations for future studies are discussed. This paper presents novel methodological, experimental, and theoretical findings that help advance human neurophysiological monitoring techniques using wearable neurotechnologies and increase the feasibility of their implementation into real-world applications.
Collapse
Affiliation(s)
- Cédric Cannard
- Centre de Recherche Cerveau et Cognition (CerCo), Centre National de la Recherche Scientifique (CNRS), Paul Sabatier University, Toulouse, France
- Institute of Noetic Sciences (IONS), Petaluma, CA, United States
| | - Helané Wahbeh
- Institute of Noetic Sciences (IONS), Petaluma, CA, United States
| | - Arnaud Delorme
- Centre de Recherche Cerveau et Cognition (CerCo), Centre National de la Recherche Scientifique (CNRS), Paul Sabatier University, Toulouse, France
- Institute of Noetic Sciences (IONS), Petaluma, CA, United States
- Swartz Center for Computational Neuroscience (SCCN), Institute of Neural Computation (INC), University of California, San Diego, San Diego, CA, United States
| |
Collapse
|
6
|
Collazos-Huertas DF, Álvarez-Meza AM, Acosta-Medina CD, Castaño-Duque GA, Castellanos-Dominguez G. CNN-based framework using spatial dropping for enhanced interpretation of neural activity in motor imagery classification. Brain Inform 2020; 7:8. [PMID: 32880784 PMCID: PMC7471227 DOI: 10.1186/s40708-020-00110-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 08/18/2020] [Indexed: 11/10/2022] Open
Abstract
Interpretation of brain activity responses using motor imagery (MI) paradigms is vital for medical diagnosis and monitoring. Assessed by machine learning techniques, identification of imagined actions is hindered by substantial intra- and inter-subject variability. Here, we develop an architecture of Convolutional Neural Networks (CNN) with an enhanced interpretation of the spatial brain neural patterns that mainly contribute to the classification of MI tasks. Two methods of 2D-feature extraction from EEG data are contrasted: Power Spectral Density and Continuous Wavelet Transform. For preserving the spatial interpretation of extracting EEG patterns, we project the multi-channel data using a topographic interpolation. Besides, we include a spatial dropping algorithm to remove the learned weights that reflect the localities not engaged with the elicited brain response. We evaluate two labeled scenarios of MI tasks: bi-class and three-class. Obtained results in an MI database show that the thresholding strategy combined with Continuous Wavelet Transform improves the accuracy and enhances the interpretability of CNN architecture, showing that the highest contribution clusters over the sensorimotor cortex with a differentiated behavior of rhythms [Formula: see text] and [Formula: see text].
Collapse
Affiliation(s)
- D. F. Collazos-Huertas
- Signal Processing and Recognition Group, Universidad Nacional de Colombia, Manizales, Colombia
| | - A. M. Álvarez-Meza
- Signal Processing and Recognition Group, Universidad Nacional de Colombia, Manizales, Colombia
| | - C. D. Acosta-Medina
- Signal Processing and Recognition Group, Universidad Nacional de Colombia, Manizales, Colombia
| | - G. A. Castaño-Duque
- Cultura de la Calidad en la Educación Research Group, Universidad Nacional de Colombia, Manizales, Colombia
| | | |
Collapse
|