1
|
Murazaki H, Wada T, Togao O, Obara M, Helle M, Kobayashi K, Ishigami K, Kato T. Improved temporal resolution and acceleration on 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) using an interpolation algorithm on the temporal axis and compressed sensing-sensitivity encoding (CS-SENSE). Magn Reson Imaging 2024; 109:1-9. [PMID: 38417470 DOI: 10.1016/j.mri.2024.02.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 02/19/2024] [Accepted: 02/20/2024] [Indexed: 03/01/2024]
Abstract
PURPOSE Two major drawbacks of 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) are the low temporal resolution and long scanning time. We investigated the feasibility of increasing the temporal resolution and accelerating the scanning time on 4D-S-PACK by using CS-SENSE and PhyZiodynamics, a novel image-processing program that interpolates images between phases to generate new phases and reduces image noise. METHODS Seven healthy volunteers were scanned with a 3.0 T MR scanner to visualize the internal carotid artery (ICA) system. PhyZiodynamics is a novel image-processing that interpolates images between phases to generate new phases and reduces image noise, and by increasing temporal resolution using PhyZiodynamics, inflow dynamic data (reference) were acquired by changing the labeling durations (100-2000 msec, 31 phases) in 4D-S-PACK. From this set of data, we selected seven time intervals to calculate interpolated time points with up to 61 intervals using ×10 for the generation of interpolated phases with PhyZiodynamics. In the denoising process of PhyZiodynamics, we processed the none, low, medium, high noise reduction dataset images. The time intensity curve (TIC), the contrast-to-noise ratio (CNR) were evaluated. In accelerating with CS-SENSE for 4D-S-PACK, 4D-S-PACK were scanned different SENSE or CS-SENSE acceleration factors: SENSE3, CS3-6. Signal intensity (SI), CNR, were evaluated for accelerating the 4D-S-PACK. With regard to arterial vascular visualization, we evaluated the middle cerebral artery (MCA: M1-4 segments). RESULTS In increasing temporal resolution, the TIC showed a similar trend between the reference dataset and the interpolated dataset. As the noise reduction weight increased, the CNR of the interpolated dataset were increased compared to that of the reference dataset. In accelerating 4D-S-PACK, the SI values of the SENSE3 dataset and CS dataset with CS3-6 were no significant differences. The image noise increased with the increase of acceleration factor, and the CNR decreased with the increase of acceleration factor. Significant differences in CNR were observed between acceleration factor of SENSE3 and CS6 for the M1-4 (P < 0.05). Visualization of small arteries (M4) became less reliable in CS5 or CS6 images. Significant differences were found for the scores of M2, M3 and M4 segments between SENSE3 and CS6. CONCLUSION With PhyZiodynamics and CS-SENSE in 4D-S-PACK, we were able to shorten the scan time while improving the temporal resolution.
Collapse
Affiliation(s)
- Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Osamu Togao
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | | | - Kouji Kobayashi
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Kousei Ishigami
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Toyoyuki Kato
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| |
Collapse
|
2
|
Togao O, Obara M, Yamashita K, Kikuchi K, Wada T, Murazaki H, Arimura K, Nishimura A, Horie N, van de Ven K, Van Cauteren M, Ishigami K. Arterial Spin Labeling-Based MR Angiography for Cerebrovascular Diseases: Principles and Clinical Applications. J Magn Reson Imaging 2023. [PMID: 37937684 DOI: 10.1002/jmri.29119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/23/2023] [Accepted: 10/23/2023] [Indexed: 11/09/2023] Open
Abstract
Arterial spin labeling (ASL) is a noninvasive imaging technique that labels the proton spins in arterial blood and uses them as endogenous tracers. Brain perfusion imaging with ASL is becoming increasingly common in clinical practice, and clinical applications of ASL for intracranial magnetic resonance angiography (MRA) have also been demonstrated. Unlike computed tomography (CT) angiography and cerebral angiography, ASL-based MRA does not require contrast agents. ASL-based MRA overcomes most of the disadvantages of time-of-flight (TOF) MRA. Several schemes have been developed for ASL-based MRA; the most common method has been pulsed ASL, but more recently pseudo-continuous ASL, which provides a higher signal-to-noise ratio (SNR), has been used more frequently. New methods that have been developed include direct intracranial labeling methods such as velocity-selective ASL and acceleration-selective ASL. MRA using an extremely short echo time (eg, silent MRA) or ultrashort echo-time (TE) MRA can suppress metal susceptibility artifacts and is ideal for patients with a metallic device implanted in a cerebral vessel. Vessel-selective 4D ASL MRA can provide digital subtraction angiography (DSA)-like images. This review highlights the principles, clinical applications, and characteristics of various ASL-based MRA techniques. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Osamu Togao
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | - Koji Yamashita
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Kazufumi Kikuchi
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koichi Arimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Ataru Nishimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Nobutaka Horie
- Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | | | | | - Kousei Ishigami
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
3
|
Tanaka F, Umino M, Maeda M, Nakayama R, Inoue K, Kogue R, Obara M, Sakuma H. Pseudocontinuous Arterial Spin Labeling: Clinical Applications and Usefulness in Head and Neck Entities. Cancers (Basel) 2022; 14:3872. [PMID: 36010866 PMCID: PMC9405982 DOI: 10.3390/cancers14163872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/01/2022] [Accepted: 08/09/2022] [Indexed: 12/02/2022] Open
Abstract
Simple Summary Conventional imaging methods, such as ultrasonography, computed tomography, and magnetic resonance imaging may be inadequate to accurately diagnose lesions of the head and neck because they vary widely. Recently, the arterial spin labeling technique, especially pseudocontinuous arterial spin labeling (pCASL) with the three-dimensional (3D) readout method, has been dramatically developed to improve diagnostic performance for lesion differentiation, which can show prominent blood flow characteristics. Here, we demonstrate the clinical usefulness of 3D pCASL for diagnosing various entities, including inflammatory lesions, hypervascular lesions, and neoplasms in the head and neck, for evaluating squamous cell carcinoma (SCC) treatment responses, and for predicting SCC prognosis. Abstract As functional magnetic resonance imaging, arterial spin labeling (ASL) techniques have been developed to provide quantitative tissue blood flow measurements, which can improve the performance of lesion diagnosis. ASL does not require contrast agents, thus, it can be applied to a variety of patients regardless of renal impairments and contrast agent allergic reactions. The clinical implementation of head and neck lesions is limited, although, in recent years, ASL has been increasingly utilized in brain lesions. Here, we review the development of the ASL techniques, including pseudocontinuous ASL (pCASL). We compare readout methods between three-dimensional (3D) turbo spin-echo and 2D echo planar pCASL for the clinical applications of pCASL to head and neck lesions. We demonstrate the clinical usefulness of 3D pCASL for diagnosing various entities, including inflammatory lesions, hypervascular lesions, and neoplasms; for evaluating squamous cell carcinoma (SCC) treatment responses, and for predicting SCC prognosis.
Collapse
|
4
|
Togao O, Obara M, Kikuchi K, Helle M, Arimura K, Nishimura A, Wada T, Murazaki H, Van Cauteren M, Hiwatashi A, Ishigami K. Vessel-Selective 4D-MRA Using Superselective Pseudocontinuous Arterial Spin-Labeling with Keyhole and View-Sharing for Visualizing Intracranial Dural AVFs. AJNR Am J Neuroradiol 2022; 43:368-375. [PMID: 35241425 PMCID: PMC8910818 DOI: 10.3174/ajnr.a7426] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 12/11/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE An accurate assessment of the hemodynamics of an intracranial dural AVF is necessary for treatment planning. We aimed to investigate the utility of 4D-MRA based on superselective pseudocontinuous arterial spin-labeling with CENTRA-keyhole and view-sharing (4D-S-PACK) for the vessel-selective visualization of intracranial dural AVFs. MATERIALS AND METHODS We retrospectively analyzed the images of 21 patients (12 men and 9 women; mean age, 62.2 [SD,19.2] years) with intracranial dural AVFs, each of whom was imaged with DSA, 4D-S-PACK, and nonselective 4D-MRA based on pseudocontinuous arterial spin-labeling combined with CENTRA-keyhole and view-sharing (4D-PACK). The shunt location, venous drainage patterns, feeding artery identification, and Borden classification were evaluated by 2 observers using both MRA methods on separate occasions. Vessel selectivity was evaluated on 4D-S-PACK. RESULTS Shunt locations were correctly evaluated in all 21 patients by both observers on both MRA methods. With 4D-S-PACK, observers 1 and 2 detected 76 (80.0%, P < .001) and 73 (76.8%, P < .001) feeding arteries of the 95 feeding arteries identified on DSA but only 39 (41.1%) and 46 (48.4%) feeding arteries with nonselective 4D-PACK, respectively. Both observers correctly identified 10 of the 11 patients with cortical venous reflux confirmed by DSA with both 4D-S-PACK and 4D-PACK (sensitivity = 90.9%, specificity = 90.9% for each method), and they made accurate Borden classifications in 20 of the 21 patients (95.2%) on both MRA methods. Of the 84 vessel territories examined, vessel selectivity was graded 3 or 4 in 73 (91.2%) and 66 (88.0%) territories by observers 1 and 2, respectively. CONCLUSIONS 4D-S-PACK is useful for the identification of feeding arteries and accurate classifications of intracranial dural AVFs and can be a useful noninvasive clinical tool.
Collapse
Affiliation(s)
- O. Togao
- From the Departments of Molecular Imaging & Diagnosis (O.T.)
| | - M. Obara
- Philips Japan (M.O., M.V.C.), Tokyo, Japan
| | | | - M. Helle
- Philips Research (M.H.), Hamburg, Germany
| | - K. Arimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - A. Nishimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - T. Wada
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - H. Murazaki
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | | | | | | |
Collapse
|
5
|
Murazaki H, Wada T, Togao O, Obara M, Helle M, Yamashita Y, Kobayashi K, Nishie A, Ishigami K, Kato T. Optimization of 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization of the internal carotid artery and vertebrobasilar artery systems. Magn Reson Imaging 2022; 85:287-96. [PMID: 34740801 DOI: 10.1016/j.mri.2021.10.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 10/29/2021] [Accepted: 10/30/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE This study investigated the optimal labeling position and gradient moment for 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective flow visualization of the internal carotid artery (ICA) and vertebrobasilar artery (VBA) systems. METHODS Seven healthy volunteers were scanned with a 3.0 T MR scanner. To visualize the ICA system, the labeling focus was placed in the right ICA at 55, 75 and 95 mm below the imaging slab. To visualize the VBA system, the labeling focus was placed in the basilar artery (BA), upper vertebral artery (VA upper), and lower vertebral artery (VA lower). Two sizes of labeling focus were created using gradient moments of 0.5 and 0.75 mT/m ms. The contrast-to-noise ratio (CNR) was measured in the middle cerebral artery (MCA) and posterior cerebral artery (PCA) branches. RESULTS CNRs increased as the distance between the center of the imaging slab and the labeling position decreased in all MCA segments. CNRs obtained with VA lower tended to be higher than those obtained with BA and VA upper in all PCA segments. Selective vessel visualization was achieved with the gradient moment of 0.75 mT/m ms for the ICA and VBA system. CONCLUSION The optimal 4D-S-PACK gradient moment was found to be 0.75 mT/m ms for the ICA and VBA systems. When visualizing the ICA system, the labeling position should be placed as close as possible to the imaging slab. When visualizing the VBA system, the labeling position should be placed at VA lower .
Collapse
|