1
|
Bell RJ, Hage DS, Dodds ED. Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry by Matrix-Assisted Laser Desorption Ionization. Anal Chem 2024; 96:6584-6587. [PMID: 38619932 DOI: 10.1021/acs.analchem.3c05601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Two-dimensional Fourier transform ion cyclotron resonance (2D FTICR) mass spectrometry is a developing form of data-independent acquisition that allows for the simultaneous fragmentation and correlation of fragment ions to their precursors across a range of m/z values. The modern usage of 2D FTICR is performed using electrospray ionization (ESI) as the dried droplet preparation for matrix-assisted laser desorption ionization (MALDI) does not produce a consistent packet of ions over a number of scans. This work uses pneumatic spray techniques from mass spectrometry imaging to create a homogeneous surface for use with MALDI as an ionization source for 2D FTICR. A mixture of peptides and matrix was deposited onto a glass slide using an HTX pneumatic sprayer. MALDI was then used to ionize the peptide mixture for use with a standard 2D FTICR pulse sequence. The generated 2D spectrum reveals comparable structural information to spectra collected in a 1D experiment. Artifacts observed in the collected 2D MALDI spectra do not significantly differ from those expected from 2D ESI spectra.
Collapse
Affiliation(s)
- Richard J Bell
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Eric D Dodds
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| |
Collapse
|
2
|
Prüfert C, Villatoro J, Zühlke M, Beitz T, Löhmannsröben HG. Liquid phase IR-MALDI and differential mobility analysis of nano- and sub-micron particles. Phys Chem Chem Phys 2022; 24:2275-2286. [PMID: 35014991 DOI: 10.1039/d1cp04196g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Infrared matrix-assisted desorption and ionization (IR-MALDI) enables the transfer of sub-micron particles (sMP) directly from suspensions into the gas phase and their characterization with differential mobility (DM) analysis. A nanosecond laser pulse at 2940 nm induces a phase explosion of the aqueous phase, dispersing the sample into nano- and microdroplets. The particles are ejected from the aqueous phase and become charged. Using IR-MALDI on sMP of up to 500 nm in diameter made it possible to surpass the 100 nm size barrier often encountered when using nano-electrospray for ionizing supramolecular structures. Thus, the charge distribution produced by IR-MALDI could be characterized systematically in the 50-500 nm size range. Well-resolved signals for up to octuply charged particles were obtained in both polarities for different particle sizes, materials, and surface modifications spanning over four orders of magnitude in concentrations. The physicochemical characterization of the IR-MALDI process was done via a detailed analysis of the charge distribution of the emerging particles, qualitatively as well as quantitatively. The Wiedensohler charge distribution, which describes the evolution of particle charging events in the gas phase, and a Poisson-derived charge distribution, which describes the evolution of charging events in the liquid phase, were compared with one another with respect to how well they describe the experimental data. Although deviations were found in both models, the IR-MALDI charging process seems to resemble a Poisson-like charge distribution mechanism, rather than a bipolar gas phase charging one.
Collapse
Affiliation(s)
- C Prüfert
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - J Villatoro
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - M Zühlke
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - T Beitz
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - H-G Löhmannsröben
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| |
Collapse
|
3
|
Murray KK. Lasers for matrix-assisted laser desorption ionization. J Mass Spectrom 2021; 56:e4664. [PMID: 33819368 DOI: 10.1002/jms.4664] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 09/19/2020] [Accepted: 09/24/2020] [Indexed: 06/12/2023]
Abstract
Matrix-assisted laser desorption ionization (MALDI) was introduced 35 years ago and has advanced from a general method for producing intact ions from large biomolecules to wide use in applications ranging from bacteria identification to tissue imaging. MALDI was enabled by the development of high energy pulsed lasers that create ions from solid samples for analysis by mass spectrometry. The original lasers used for MALDI were ultraviolet fixed-wavelength nitrogen and Nd:YAG lasers, and a number of additional laser sources have been subsequently introduced with wavelengths ranging from the infrared to the ultraviolet and pulse widths from nanosecond to femtosecond. Wavelength tunable sources have been employed both in the IR and UV, and repetition rates have increased from tens of Hz to tens of kHz as MALDI has moved into mass spectrometry imaging. Dual-pulse configurations have been implemented with two lasers directed at the target or with a second laser creating ions in the plume of desorbed material. This review provides a brief history of the use of lasers for ionization in mass spectrometry and describes the various types of lasers and configurations used for MALDI.
Collapse
Affiliation(s)
- Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, USA
| |
Collapse
|
4
|
Trimpin S. Novel ionization processes for use in mass spectrometry: 'Squeezing' nonvolatile analyte ions from crystals and droplets. Rapid Commun Mass Spectrom 2019; 33 Suppl 3:96-120. [PMID: 30138957 DOI: 10.1002/rcm.8269] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/29/2018] [Accepted: 08/15/2018] [Indexed: 05/25/2023]
Abstract
Together with my group and collaborators, I have been fortunate to have had a key role in the discovery of new ionization processes that we developed into new flexible, sensitive, rapid, reliable, and robust ionization technologies and methods for use in mass spectrometry (MS). Our current research is focused on how best to understand, improve, and use these novel ionization processes which convert volatile and nonvolatile compounds from solids or liquids into gas-phase ions for analysis by MS using e.g. mass-selected fragmentation and ion mobility spectrometry to provide reproducible, accurate, and improved mass and drift time resolution. In my view, the apex was the discovery of vacuum matrix-assisted ionization (vMAI) in 2012 on an intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source without the use of a laser, high voltages, or any other added energy. Only exposure of the matrix:analyte to the sub-atmospheric pressure of the mass spectrometer was necessary to initiate ionization. These findings were initially rejected by three different scientific journals, with comments related to 'how can this work?', 'where do the charges come from?', and 'it is not analytically useful'. Meanwhile, we and others have demonstrated analytical utility without a complete understanding of the mechanism. In reality, MALDI and electrospray ionization are widely used in science and their mechanisms are still controversially discussed despite use and optimization of now 30 years. This Perspective covers the applications and mechanistic aspects of the novel ionization processes for use in MS that guided us in instrument developments, and provides our perspective on how they relate to traditional ionization processes.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- Cardiovascular Research Institute, Wayne State University School of Medicine, Detroit, MI, 48201, USA
- MSTM, LLC, Newark, DE, 19711, USA
| |
Collapse
|
5
|
Lawal RO, Donnarumma F, Murray KK. Deep-ultraviolet laser ablation electrospray ionization mass spectrometry. J Mass Spectrom 2019; 54:281-287. [PMID: 30675964 PMCID: PMC6422691 DOI: 10.1002/jms.4338] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 01/12/2019] [Accepted: 01/18/2019] [Indexed: 06/02/2023]
Abstract
A 193-nm wavelength deep ultraviolet laser was used for ambient laser ablation electrospray ionization mass spectrometry of biological samples. A pulsed ArF excimer laser was used to ablate solid samples, and the resulting plume of the desorbed material merged with charged electrospray droplets to form ions that were detected with a quadrupole time-of-flight mass spectrometer. Solutions containing peptide and protein standards up to 66-kDa molecular weight were deposited on a metal target, dried, and analyzed. No fragmentation was observed from peptides and proteins as well as from the more easily fragmented vitamin B12 molecule. The mass spectra contained peaks from multiply charged ions that were identical to conventional electrospray. Deep UV laser ablation of tissue allowed detection of lipids from untreated tissue. The mechanism of ionization is postulated to involve absorption of laser energy by a fraction of the analyte molecules that act as a sacrificial matrix or by residual water in the sample.
Collapse
Affiliation(s)
- Remilekun O. Lawal
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana. 70803, USA
| | - Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana. 70803, USA
| | - Kermit K. Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana. 70803, USA
| |
Collapse
|
6
|
Trimpin S, Lee C, Weidner SM, El‐Baba TJ, Lutomski CA, Inutan ED, Foley CD, Ni C, McEwen CN. Unprecedented Ionization Processes in Mass Spectrometry Provide Missing Link between ESI and MALDI. Chemphyschem 2018; 19:581-589. [DOI: 10.1002/cphc.201701246] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 12/01/2017] [Indexed: 01/07/2023]
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry Wayne State University 5101 Cass Ave Detroit MI 48202 USA
| | - Chuping Lee
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Steffen M. Weidner
- Federal Institute for Materials Research and Testing (BAM) Richard-Willstätter-Strasse 11 12489 Berlin Germany
| | - Tarick J. El‐Baba
- Department of Chemistry Wayne State University 5101 Cass Ave Detroit MI 48202 USA
| | - Corinne A. Lutomski
- Department of Chemistry Wayne State University 5101 Cass Ave Detroit MI 48202 USA
| | - Ellen D. Inutan
- Department of Chemistry Wayne State University 5101 Cass Ave Detroit MI 48202 USA
| | - Casey D. Foley
- Department of Chemistry Wayne State University 5101 Cass Ave Detroit MI 48202 USA
| | - Chi‐Kung Ni
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Charles N. McEwen
- Department of Chemistry & Biochemistry University of the Sciences Philadelphia PA 19104 USA
| |
Collapse
|
7
|
Hollerbach A, Logsdon D, Iyer K, Li A, Schaber JA, Graham Cooks R. Sizing sub-diffraction limit electrosprayed droplets by structured illumination microscopy. Analyst 2018; 143:232-240. [PMID: 29138765 DOI: 10.1039/c7an01278k] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Electrosprayed droplets are widely studied for their role in the formation of ions at atmospheric pressure.
Collapse
Affiliation(s)
| | - David Logsdon
- Chemistry Department
- Purdue University
- West Lafayette
- USA
| | - Kiran Iyer
- Chemistry Department
- Purdue University
- West Lafayette
- USA
| | - Anyin Li
- Chemistry Department
- Purdue University
- West Lafayette
- USA
| | - J. Andy Schaber
- Bioscience Imaging Facility
- Bindley Bioscience Center
- Purdue University
- West Lafayette
- USA
| | | |
Collapse
|
8
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2011-2012. Mass Spectrom Rev 2017; 36:255-422. [PMID: 26270629 DOI: 10.1002/mas.21471] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Accepted: 01/15/2015] [Indexed: 06/04/2023]
Abstract
This review is the seventh update of the original article published in 1999 on the application of MALDI mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2012. General aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, and fragmentation are covered in the first part of the review and applications to various structural types constitute the remainder. The main groups of compound are oligo- and poly-saccharides, glycoproteins, glycolipids, glycosides, and biopharmaceuticals. Much of this material is presented in tabular form. Also discussed are medical and industrial applications of the technique, studies of enzyme reactions, and applications to chemical synthesis. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:255-422, 2017.
Collapse
Affiliation(s)
- David J Harvey
- Department of Biochemistry, Oxford Glycobiology Institute, University of Oxford, Oxford, OX1 3QU, UK
| |
Collapse
|
9
|
Xiong C, Zhou X, He Q, Huang X, Wang J, Peng WP, Chang HC, Nie Z. Development of Visible-Wavelength MALDI Cell Mass Spectrometry for High-Efficiency Single-Cell Analysis. Anal Chem 2016; 88:11913-11918. [DOI: 10.1021/acs.analchem.6b03789] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Caiqiao Xiong
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
| | - Xiaoyu Zhou
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
| | - Qing He
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
| | - Xi Huang
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
| | - Jiyun Wang
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
| | - Wen-Ping Peng
- Department
of Physics, National Dong Hwa University, Shoufeng, Hualien 97401, Taiwan
| | - Huan-Cheng Chang
- Institute
of Atomic and Molecular Sciences, Academia Sinica, Taipei 106, Taiwan
| | - Zongxiu Nie
- Key
Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences, Beijing 100190, China
- National Center for Mass Spectrometry in Beijing, Beijing 100190, China
| |
Collapse
|
10
|
Bufalo G, Ambrosone L. Method for Determining the Activation Energy Distribution Function of Complex Reactions by Sieving and Thermogravimetric Measurements. J Phys Chem B 2016; 120:244-9. [PMID: 26671287 DOI: 10.1021/acs.jpcb.5b10448] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A method for studying the kinetics of thermal degradation of complex compounds is suggested. Although the method is applicable to any matrix whose grain size can be measured, herein we focus our investigation on thermogravimetric analysis, under a nitrogen atmosphere, of ground soft wheat and ground maize. The thermogravimetric curves reveal that there are two well-distinct jumps of mass loss. They correspond to volatilization, which is in the temperature range 298-433 K, and decomposition regions go from 450 to 1073 K. Thermal degradation is schematized as a reaction in the solid state whose kinetics is analyzed separately in each of the two regions. By means of a sieving analysis different size fractions of the material are separated and studied. A quasi-Newton fitting algorithm is used to obtain the grain size distribution as best fit to experimental data. The individual fractions are thermogravimetrically analyzed for deriving the functional relationship between activation energy of the degradation reactions and the particle size. Such functional relationship turns out to be crucial to evaluate the moments of the activation energy distribution, which is unknown in terms of the distribution calculated by sieve analysis. From the knowledge of moments one can reconstruct the reaction conversion. The method is applied first to the volatilization region, then to the decomposition region. The comparison with the experimental data reveals that the method reproduces the experimental conversion with an accuracy of 5-10% in the volatilization region and of 3-5% in the decomposition region.
Collapse
|
11
|
Abstract
The systematic study of the temperature and pressure dependence of matrix-assisted ionization (MAI) led us to the discovery of the seemingly impossible, initially explained by some reviewers as either sleight of hand or the misinterpretation by an overzealous young scientist of results reported many years before and having little utility. The “magic” that we were attempting to report was that with matrix assistance, molecules, at least as large as bovine serum albumin (66 kDa), are lifted into the gas phase as multiply charged ions simply by exposure of the matrix:analyte sample to the vacuum of a mass spectrometer. Applied heat, a laser, or voltages are not necessary to achieve charge states and ion abundances only previously observed with electrospray ionization (ESI). The fundamentals of how solid phase volatile or nonvolatile compounds are converted to gas-phase ions without added energy currently involves speculation providing a great opportunity to rethink mechanistic understanding of ionization processes used in mass spectrometry. Improved understanding of the mechanism(s) of these processes and their connection to ESI and matrix-assisted laser desorption/ionization may provide opportunities to further develop new ionization strategies for traditional and yet unforeseen applications of mass spectrometry. This Critical Insights article covers developments leading to the discovery of a seemingly magic ionization process that is simple to use, fast, sensitive, robust, and can be directly applied to surface characterization using portable or high performance mass spectrometers.
Collapse
Affiliation(s)
- Sarah Trimpin
- />Department of Chemistry, Wayne State University, Detroit, MI 48202 USA
- />Cardiovascular Research Institute, Wayne State University School of Medicine, Detroit, MI 48201 USA
- />MSTM, LLC, Newark, DE 19711 USA
| |
Collapse
|
12
|
Abstract
The concentration and size distribution were measured for particles ablated from tissue sections using an infrared optical parametric oscillator laser system. A scanning mobility particle sizer and light scattering particle sizer were used in parallel to realize a particle sizing range from 10 nm to 20 μm. Tissue sections from rat brain and lung ranging in thickness between 10 and 50 μm were mounted on microscope slides and irradiated with nanosecond laser pulses at 3 μm wavelength and fluences between 7 and 21 kJ m(-2) in reflection geometry. The particle size distributions were characterized by a bimodal distribution with a large number of particles 100 nm in diameter and below and a large mass contribution from particles greater than 1 μm in diameter. The large particle contribution dominated the ablated particle mass at high laser fluence. The tissue type, thickness, and water content did not have a significant effect on the particle size distributions. The implications of these results for laser ablation sampling and mass spectrometry imaging under ambient conditions are discussed.
Collapse
Affiliation(s)
- Fan Cao
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana. 70803, USA.
| | | | | |
Collapse
|
13
|
Moskovets E. Ghost peaks observed after atmospheric pressure matrix-assisted laser desorption/ionization experiments may disclose new ionization mechanism of matrix-assisted hypersonic velocity impact ionization. Rapid Commun Mass Spectrom 2015; 29:1501-12. [PMID: 26212165 PMCID: PMC4518465 DOI: 10.1002/rcm.7248] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Revised: 05/28/2015] [Accepted: 06/09/2015] [Indexed: 05/12/2023]
Abstract
RATIONALE Understanding the mechanisms of matrix-assisted laser desorption/ionization (MALDI) promises improvements in the sensitivity and specificity of many established applications in the field of mass spectrometry. This paper reports a serendipitous observation of a significant ion yield in a post-ionization experiment conducted after the sample had been removed from a standard atmospheric pressure (AP)-MALDI source. This post-ionization is interpreted in terms of collisions of microparticles moving with a hypersonic velocity into a solid surface. Calculations show that the thermal energy released during such collisions is close to that absorbed by the top matrix layer in traditional MALDI. The microparticles, containing both the matrix and analytes, could be detached from a film produced inside the inlet capillary during the sample ablation and accelerated by the flow rushing through the capillary. These observations contribute some new perspective to ion formation in both laser and laser-less matrix-assisted ionization. METHODS An AP-MALDI ion source hyphenated with a three-stage high-pressure ion funnel system was utilized for peptide mass analysis. After the laser had been turned off and the MALDI sample removed, ions were detected during a gradual reduction of the background pressure in the first funnel. The constant-rate pressure reduction led to the reproducible appearance of different singly and doubly charged peptide peaks in mass spectra taken a few seconds after the end of the MALDI analysis of a dried-droplet spot. RESULTS The ion yield as well as the mass range of ions observed with a significant delay after a completion of the primary MALDI analysis depended primarily on the background pressure inside the first funnel. The production of ions in this post-ionization step was exclusively observed during the pressure drop. A lower matrix background and significant increase in relative yield of double-protonated ions are reported. CONCLUSIONS The observations were partially consistent with a model of the supersonic jet from the inlet capillary accelerating detached particles to kinetic energies suitable for matrix-assisted hypersonic-velocity impact ionization.
Collapse
Affiliation(s)
- Eugene Moskovets
- MassTech Inc., 6992 Columbia Gateway Dr., Columbia MD, USA, Phone: 443-539-0139
| |
Collapse
|
14
|
Musapelo T, Murray KK. Particle formation by infrared laser ablation of MALDI matrix compounds. J Mass Spectrom 2014; 49:543-549. [PMID: 25044838 DOI: 10.1002/jms.3378] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2013] [Revised: 04/15/2014] [Accepted: 04/15/2014] [Indexed: 06/03/2023]
Abstract
The concentration and size distribution of particles ablated from the infrared matrix-assisted laser desorption/ionization matrix compounds succinic acid (butanedioic acid), α-cyano-4-hydroxycinnamic acid, and glycerol were measured using an aerodynamic particle sizer combined with a scanning mobility particle sizer. The two sizing instruments together had a sizing range to from 10 nm to 20 µm. Thin layers of the matrix compounds were irradiated with fluences between 6.0 and 9.5 kJ/m(2) and wavelengths between 2.8 and 3.0 µm. The distribution of particles was characterized by a large concentration of clusters in the 20-nm-diameter range and large component of mass in the range of coarse particle with diameters greater than 1 µm. The wavelength dependence revealed a blue shift for the maximum particle production that is attributed to heating and disruption of the hydrogen bonds in the matrix that shifts the absorption to shorter wavelengths. This blue shift has been observed previously in infrared matrix-assisted laser desorption/ionization.
Collapse
Affiliation(s)
- Thabiso Musapelo
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | | |
Collapse
|
15
|
Abstract
Covering: 2013 The ability to transfer molecular species to the gas phase and ionize them is central to the study of natural products and other molecular species by mass spectrometry (MS). MS-based strategies in natural products have focused on a few established ion sources, such as electron impact and electrospray ionization. However, a variety of other ion sources are either currently in use to evaluate natural products or show significant future promise. This review discusses these various ion sources in the context of other articles in this special issue, but is also applicable to other fields of analysis, including materials science. Ion sources are grouped based on the current understanding of their predominant ion formation mechanisms. This broad overview groups ion sources into the following categories: electron ionization and single photon ionization; chemical ionization-like and plasma-based; electrospray ionization; and, laser desorption-based. Laser desorption-based methods are emphasized with specific examples given for laser desorption postionization sources and their use in the analysis of intact microbial biofilms. Brief consideration is given to the choice of ion source for various sample types and analyses, including MS imaging.
Collapse
Affiliation(s)
- Chhavi Bhardwaj
- Department of Chemistry, University of Illinois at Chicago, mc 111, Chicago, IL 60607-7061.
| | | |
Collapse
|
16
|
Flanigan P, Levis R. Ambient femtosecond laser vaporization and nanosecond laser desorption electrospray ionization mass spectrometry. Annu Rev Anal Chem (Palo Alto Calif) 2014; 7:229-256. [PMID: 25014343 DOI: 10.1146/annurev-anchem-071213-020343] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Recent investigations of ambient laser-based transfer of molecules into the gas phase for subsequent mass spectral analysis have undergone a renaissance resulting from the separation of vaporization and ionization events. Here, we seek to provide a snapshot of recent femtosecond (fs) duration laser vaporization and nanosecond (ns) duration laser desorption electrospray ionization mass spectrometry experiments. The former employs pulse durations of <100 fs to enable matrix-free laser vaporization with little or no fragmentation. When coupled to electrospray ionization, femtosecond laser vaporization provides a universal, rapid mass spectral analysis method requiring no sample workup. Remarkably, laser pulses with intensities exceeding 10(13) W cm(-2) desorb intact macromolecules, such as proteins, and even preserve the condensed phase of folded or unfolded protein structures according to the mass spectral charge state distribution, as demonstrated for cytochrome c and lysozyme. Because of the ability to vaporize and ionize multiple components from complex mixtures for subsequent analysis, near perfect classification of explosive formulations, plant tissue phenotypes, and even the identity of the manufacturer of smokeless powders can be determined by multivariate statistics. We also review the more mature field of nanosecond laser desorption for ambient mass spectrometry, covering the wide range of systems analyzed, the need for resonant absorption, and the spatial imaging of complex systems like tissue samples.
Collapse
Affiliation(s)
- Paul Flanigan
- Center for Advanced Photonics Research, Department of Chemistry, Temple University, Philadelphia, Pennsylvania 19122; ,
| | | |
Collapse
|
17
|
Bae YJ, Choe JC, Moon JH, Kim MS. Why do the abundances of ions generated by MALDI look thermally determined? J Am Soc Mass Spectrom 2013; 24:1807-1815. [PMID: 23990058 DOI: 10.1007/s13361-013-0717-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 07/23/2013] [Accepted: 07/23/2013] [Indexed: 06/02/2023]
Abstract
In a previous study (J. Mass Spectrom. 48, 299-305, 2013), we observed that the abundance of each ion in a matrix-assisted laser desorption ionization (MALDI) spectrum looked thermally determined. To find out the explanation for the phenomenon, we estimated the ionization efficiency and the reaction quotient (QA) for the autoprotolysis of matrix, M + M → [M + H](+) + [M - H](-), from the temperature-controlled laser desorption ionization spectra of α-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB). We also evaluated the equilibrium constants (KA) for the autoprotolysis at various temperatures by quantum chemical calculation. Primary ion formation via various thermal models followed by autoprotolysis-recombination was compatible with the observations. The upper limit of the effective temperature of the plume where autoprotolysis-recombination occurs was estimated by equating QA with the calculated equilibrium constant. Figure ᅟ
Collapse
Affiliation(s)
- Yong Jin Bae
- Department of Chemistry, Seoul National University, Seoul, 151-747, Korea
| | | | | | | |
Collapse
|
18
|
Kaufman E, Smith W, Kowalski M, Beech I, Sunner J. Electric-field-enhanced collection of laser-ablated materials onto a solvent bridge for electrospray ionization mass spectrometry. Rapid Commun Mass Spectrom 2013; 27:1567-1572. [PMID: 23722691 DOI: 10.1002/rcm.6600] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 04/07/2013] [Accepted: 04/15/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Ambient imaging mass spectrometry methods are critically dependent on the ability to efficiently collect all substances from a well-defined area of the sample. Improvements in this area are critical and enabling. METHODS Methods for the efficient collection of laser-ablated materials directly into a solvent, for immediate transport to an ion source, have been explored using the application of electric fields. RESULTS Electric-field-enhanced collection of laser-ablated materials has been demonstrated. Demonstrated increases in collection efficiency are as large as two orders of magnitude, in particular for hydrated biological materials, such as living bacterial colonies. This was achieved by applying approximately 1 kV between the sample and the receiving solvent surface. CONCLUSIONS Electric-field-enhanced collection of laser-ablated materials holds great promise for ambient sampling and imaging mass spectrometry with rapid and direct interfacing to ionization sources, such as electrospray.
Collapse
Affiliation(s)
- Eric Kaufman
- Department of Microbiology and Plant Biology, University of Oklahoma, Norman, OK 73019-5251, USA
| | | | | | | | | |
Collapse
|
19
|
Musapelo T, Murray KK. Particle production in reflection and transmission mode laser ablation: implications for laserspray ionization. J Am Soc Mass Spectrom 2013; 24:1108-15. [PMID: 23633017 DOI: 10.1007/s13361-013-0631-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 03/23/2013] [Accepted: 03/26/2013] [Indexed: 05/25/2023]
Abstract
Particles were ablated from laser desorption and inlet ionization matrix thin films with a UV laser in reflection and transmission geometries. Particle size distributions were measured with a combined scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) system that measured particles in the size range from 10 nm to 20 μm. The matrixes investigated were 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), sinapic acid (SA), 2,5-dihydroxy-acetophenone (DHAP), and 2-nitrophloroglucinol (NPG). Nanoparticles with average diameters between 20 and 120 nm were observed in both transmission and reflection geometry. The particle mass distribution was significantly different in reflection and transmission geometry. In reflection geometry, approximately equal mass was distributed between particles in the 20 to 450 nm range of diameters and particles in the 450 nm to 1.5 μm diameter range. In transmission mode, the particle mass distribution was dominated by large particles in the 2 to 20 μm diameter range. Ablation of inlet ionization matrices DHAP and NPG produced particles that were 3 to 4 times smaller compared with the other matrices. The results are consistent with ion formation by nanoparticle melting and breakup or melting and breakup of the large particles through contact with heated inlet surfaces. ᅟ
Collapse
Affiliation(s)
- Thabiso Musapelo
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, USA
| | | |
Collapse
|
20
|
Fan X, Wang SZ, Zheng AL, Wei XY, Zhao YP, Zong ZM, Zhao W. Investigation on infrared laser desorption of solid matrix using scanning electron microscope and fast photography. Microsc Res Tech 2013; 76:744-50. [DOI: 10.1002/jemt.22225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2013] [Revised: 03/18/2013] [Accepted: 04/06/2013] [Indexed: 12/14/2022]
Affiliation(s)
| | - Shou-Ze Wang
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| | - Ai-Li Zheng
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| | - Xian-Yong Wei
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| | - Yun-Peng Zhao
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| | - Zhi-Min Zong
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| | - Wei Zhao
- School of Chemical Engineering; China University of Mining and Technology; Xuzhou; 221116; Jiangsu; People's Republic of China
| |
Collapse
|
21
|
Musapelo T, Murray KK. Size distributions of ambient shock-generated particles: implications for inlet ionization. Rapid Commun Mass Spectrom 2013; 27:1283-6. [PMID: 23650042 DOI: 10.1002/rcm.6568] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 03/11/2013] [Accepted: 03/11/2013] [Indexed: 05/25/2023]
|
22
|
Monge ME, Harris GA, Dwivedi P, Fernández FM. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chem Rev 2013; 113:2269-308. [DOI: 10.1021/cr300309q] [Citation(s) in RCA: 404] [Impact Index Per Article: 36.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- María Eugenia Monge
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Glenn A. Harris
- Department
of Biochemistry and
the Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Prabha Dwivedi
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| |
Collapse
|
23
|
Trimpin S, Wang B, Inutan ED, Li J, Lietz CB, Harron A, Pagnotti VS, Sardelis D, McEwen CN. A mechanism for ionization of nonvolatile compounds in mass spectrometry: considerations from MALDI and inlet ionization. J Am Soc Mass Spectrom 2012; 23:1644-60. [PMID: 22791582 DOI: 10.1007/s13361-012-0414-y] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2011] [Revised: 05/09/2012] [Accepted: 05/11/2012] [Indexed: 05/12/2023]
Abstract
Mechanistic arguments relative to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) address observations that predominately singly charged ions are detected. However, recently a matrix assisted laser ablation method, laserspray ionization (LSI), was introduced that can use the same sample preparation and laser as MALDI, but produce highly charged ions from proteins. In MALDI, ions are generated from neutral molecules by the photon energy provided to a matrix, while in LSI ions are produced inside a heated inlet tube linking atmospheric pressure and the first vacuum region of the mass spectrometer. Some LSI matrices also produce highly charged ions with MALDI ion sources operated at intermediate pressure or high vacuum. The operational similarity of LSI to MALDI, and the large difference in charge states observed by these methods, provides information of fundamental importance to proposed ionization mechanisms for LSI and MALDI. Here, we present data suggesting that the prompt and delayed ionization reported for vacuum MALDI are both fast processes relative to producing highly charged ions by LSI. The energy supplied to produce these charged clusters/droplets as well as their size and time available for desolvation are determining factors in the charge states of the ions observed. Further, charged droplets/clusters may be a common link for ionization of nonvolatile compounds by a variety of MS ionization methods, including MALDI and LSI.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI 48202, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Bae YJ, Shin YS, Moon JH, Kim MS. Degree of ionization in MALDI of peptides: thermal explanation for the gas-phase ion formation. J Am Soc Mass Spectrom 2012; 23:1326-35. [PMID: 22653466 DOI: 10.1007/s13361-012-0406-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 04/24/2012] [Accepted: 04/27/2012] [Indexed: 05/20/2023]
Abstract
Degree of ionization (DI) in matrix-assisted laser desorption ionization (MALDI) was measured for five peptides using α-cyano-4-hydroxycinnanmic acid (CHCA) as the matrix. DIs were low 10(-4) for peptides and 10(-7) for CHCA. Total number of ions (i.e., peptide plus matrix) was the same regardless of peptides and their concentration, setting the number of gas-phase ions generated from a pure matrix as the upper limit to that of peptide ions. Positively charged cluster ions were too weak to support the ion formation via such ions. The total number of gas-phase ions generated by MALDI, and that from pure CHCA, was unaffected by the laser pulse energy, invalidating laser-induced ionization of matrix molecules as the mechanism for the primary ion formation. Instead, the excitation of matrix by laser is simply a way of supplying thermal energy to the sample. Accepting strong Coulomb attraction felt by cations in a solid sample, we propose three hypotheses for gas-phase peptide ion formation. In Hypothesis 1, they originate from the dielectrically screened peptide ions in the sample. In Hypothesis 2, the preformed peptide ions are released as part of neutral ion pairs, which generate gas-phase peptide ions via reaction with matrix-derived cations. In Hypothesis 3, neutral peptides released by ablation get protonated via reaction with matrix-derived cations.
Collapse
Affiliation(s)
- Yong Jin Bae
- Department of Chemistry, Seoul National University, Seoul 151-742, Korea
| | | | | | | |
Collapse
|