1
|
Magahis PT, Westerveld D, Simons M, Carr-Locke DL, Sampath K, Sharaiha RZ, Mahadev S. Outcomes of Endoscopic Ultrasound-guided Fine Needle Biopsy Using a Novel Hydrostatic Stylet Tissue Acquisition Technique. J Clin Gastroenterol 2024; 58:407-414. [PMID: 37983811 DOI: 10.1097/mcg.0000000000001934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 09/28/2023] [Indexed: 11/22/2023]
Abstract
BACKGROUND Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is frequently used to obtain core samples of solid lesions. Here, we describe and evaluate a novel hydrostatic stylet (HS) technique designed to optimize core sample acquisition, reporting diagnostic yield, efficacy, and safety relative to the conventional stylet slow-pull (SP) technique. METHODS A novel HS technique was developed and validated retrospectively. Consecutive patients who underwent EUS-FNB with core biopsy of solid lesions through either the HS or SP technique between January 2020 and April 2022 were included. Exclusion criteria included cystic lesions, nonlesional liver biopsies, and specimens sent for cytologic analysis only. Patient and lesion characteristics, number of passes, sample adequacy, and adverse events were compared between the two techniques. RESULTS A total of 272 patients were included with 138 in the HS group and 134 in the SP group. Lesion size and anatomic distribution were similar in both groups. Compared with the SP approach, the HS technique demonstrated significantly higher sample adequacy (97.8% vs 83.6%, P < 0.001), higher sensitivity (97.1% vs 89.7%, P = 0.03), and lower mean number of passes (1.2 vs 3.3, P < 0.001). Rates and severity of adverse events in the HS group were comparable to the SP group and existing literature. Similar associations were observed in pancreatic and nonpancreatic lesion subanalyses. CONCLUSIONS The novel HS technique demonstrated excellent biopsy sample adequacy and diagnostic yield while requiring fewer passes to obtain diagnostic specimens compared with a conventional EUS-FNB approach. Further prospective evaluation is needed to confirm these pilot findings and optimize EUS-FNB acquisition techniques.
Collapse
Affiliation(s)
| | - Donevan Westerveld
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| | - Malorie Simons
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| | - David L Carr-Locke
- MD Program, Weill Cornell Medical College
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| | - Kartik Sampath
- MD Program, Weill Cornell Medical College
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| | - Reem Z Sharaiha
- MD Program, Weill Cornell Medical College
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| | - SriHari Mahadev
- MD Program, Weill Cornell Medical College
- Division of Gastroenterology and Hepatology, New York-Presbyterian Hospital/Weill Cornell Medicine, New York, NY
| |
Collapse
|
2
|
Iwashita T, Uemura S, Ryuichi T, Senju A, Iwata S, Ohashi Y, Shimizu M. Advances and efficacy in specimen handling for endoscopic ultrasound-guided fine needle aspiration and biopsy: A comprehensive review. DEN Open 2024; 4:e350. [PMID: 38495467 PMCID: PMC10941515 DOI: 10.1002/deo2.350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 02/19/2024] [Accepted: 02/23/2024] [Indexed: 03/19/2024]
Abstract
Endoscopic ultrasound-guided fine needle aspiration and biopsy have significantly evolved since they offer a minimally invasive approach for obtaining pathological specimens from lesions adjacent to or within the intestine. This paper reviews advancements in endoscopic ultrasound-guided fine needle aspiration and biopsy techniques and devices, emphasizing the importance of handling specimens for diagnostic accuracy. Innovations of fine needle biopsy needles with features like side holes and Franseen shapes have enhanced histological sampling capabilities. Techniques for specimen handling, including rapid on-site evaluation and macroscopic on-site evaluation, play pivotal roles in assessing sample adequacy, thereby influencing diagnostic outcomes. The utility of artificial intelligence in augmenting rapid on-site evaluation and macroscopic on-site evaluation, although still in experimental stages, presents a promising avenue for improving procedural efficiency and diagnostic precision. The choice of specimen handling technique is dependent on various factors including endoscopist preference, procedure objectives, and available resources, underscoring the need for a comprehensive understanding of each method's characteristics to optimize diagnostic efficacy and procedural safety.
Collapse
Affiliation(s)
- Takuji Iwashita
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Shinya Uemura
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Tezuka Ryuichi
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Akihiko Senju
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Shota Iwata
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Yosuke Ohashi
- First Department of Internal MedicineGifu University HospitalGifuJapan
| | - Masahito Shimizu
- First Department of Internal MedicineGifu University HospitalGifuJapan
| |
Collapse
|
3
|
Mangiavillano B, Facciorusso A, Di Matteo FM, Barbera C, Larghi A, Rizzatti G, Carrara S, Lisotti A, Fusaroli P, De Luca L, Di Leo M, Conti Bellocchi MC, Spadaccini M, Dabizzi E, Auriemma F, Stigliano S, Ramai D, Calabrese F, Manfrin E, Paduano D, Hassan C, Repici A, Crinó SF. Establishing the optimal number of passes during EUS-FNB for diagnosis of pancreatic solid lesions: Prospective multicenter study. Endosc Int Open 2024; 12:E467-E473. [PMID: 38585018 PMCID: PMC10997423 DOI: 10.1055/a-2236-7654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 12/19/2023] [Indexed: 04/09/2024] Open
Abstract
Background and study aims The optimal number of needle passes during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is not yet established. We aimed to perform a per-pass analysis of the diagnostic accuracy of EUS-FNB of solid pancreatic lesions using a 22G Franseen needle. Patients and methods Consecutive patients with solid pancreatic lesions referred to 11 Italian centers were prospectively enrolled. Three needle passes were performed; specimens were collected after each pass and processed individually as standard histology following macroscopic on-site evaluation (MOSE) by the endoscopist. The primary endpoint was diagnostic accuracy of each sequential pass. Final diagnosis was established based on surgical pathology or a clinical course of at least 6 months. Secondary endpoints were specimen adequacy, MOSE reliability, factors impacting diagnostic accuracy, and procedure-related adverse events. Results A total of 504 samples from 168 patients were evaluated. Diagnostic accuracy was 90.5% (85.0%-94.1%) after one pass and 97.6% (94.1%-99.3%) after two passes ( P =0.01). Similarly, diagnostic sensitivity and sample adequacy were significantly higher adding the second needle pass (90.2%, 84.6%-94.3% vs 97.5%, 93.8%-99.3%, P =0.009 and 91.1%, 85.7%-94.9% vs 98.2%, 95.8%-99.3%, P =0.009, one pass vs two passes, respectively). Accuracy, sensitivity, and adequacy remained the same after the third pass. The concordance between MOSE and histological evaluation was 89.9%. The number of passes was the only factor associated with accuracy. One case of mild acute pancreatitis (0.6%) was managed conservatively. Conclusions At least two passes should be performed for the diagnosis of solid pancreatic lesions. MOSE is a reliable tool to predict the histological adequacy of specimens.
Collapse
Affiliation(s)
- Benedetto Mangiavillano
- Gastrointestinal Endoscopy, Istituto Clinico Mater Domini Casa di Cura Privata SpA, Castellanza, Italy
| | | | | | - Carmelo Barbera
- Gastroenterology and Digestive Endoscopy Unit, Nuovo Ospedale Civile S. Agostino-Estense, Baggiovara di Modena (Mo), Italy
- Gastroenterology and Digestive Endoscopy Unit, Azienda Unita Sanitaria Locale di Modena, Italy
| | - Alberto Larghi
- Digestive Endoscopy Unit, Universita' Cattolica del Sacro Cuore, Rome, Italy
| | - Gianenrico Rizzatti
- Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Silvia Carrara
- Digestive Endoscopy, Istituto Clinico Humanitas, Rozzano, Italy
| | - Andrea Lisotti
- Gastroenterology Unit, Hospital of Imola, University of Bologna, Imola, Italy
| | | | - Luca De Luca
- Gastroenterology and Digestive Endoscopy, Azienda Ospedaliera Ospedali Riuniti Marche Nord, Pesaro, Italy
| | - Milena Di Leo
- Division of Gastroenterology, Digestive Endoscopy Unit, Rozzano (Milan), Italy
- Department of Biomedical Science, Humanitas University, Milan, Italy
| | | | - Marco Spadaccini
- Digestive Endoscopy Unit, Division of Gastroenterology, Istituto Clinico Humanitas, Rozzano, Italy
| | - Emanuele Dabizzi
- Digestive Endoscopy, Nuovo Ospedale Civile S. Agostino Estense di Baggiovara, Modena, Modena, Italy
| | - Francesco Auriemma
- Digestive Endoscopy Unit, Division of Gastroenterology, Istituto Clinico Humanitas, Rozzano, Italy
- Gastroenterologia, Università Federico II, Napoli, Italy
| | - Serena Stigliano
- Operative Endoscopy Department, Campus Bio-Medico University, Roma, Italy
| | - Daryl Ramai
- Gastroenterology and Hepatology, The University of Utah School of Medicine, Salt Lake City, United States
| | - Federica Calabrese
- Gastrointestinal Endoscopy, Istituto Clinico Mater Domini Casa di Cura Privata SpA, Castellanza, Varese, Italy
| | - Erminia Manfrin
- Department of Diagnostics and Public Health, University of Verona Hospital Trust P.Le L.A. Scuro 10, Verona, Italy
| | - Danilo Paduano
- Gastrointestinal Endoscopy Unit, Humanitas Mater Domini, Castellanza, Italy
| | - Cesare Hassan
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
- Endoscopy Unit, IRCCS Humanitas Clinical and Research Center, Milan, Italy
| | - Alessandro Repici
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
- Digestive Endoscopy Unit, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Stefano Francesco Crinó
- Gastroenterology and Digestive Endoscopy Unit, Pancreas Institute, University of Verona, Verona, Italy
| |
Collapse
|
4
|
Facciorusso A, Crinò SF, Fugazza A, Carrara S, Spadaccini M, Colombo M, Ramai D, Mangiavillano B, Chandan S, Gkolfakis P, Mohan B, Hassan C, Repici A. Comparative diagnostic yield of different endoscopic techniques for tissue sampling of upper gastrointestinal subepithelial lesions: a network meta-analysis. Endoscopy 2024; 56:31-40. [PMID: 37591258 DOI: 10.1055/a-2156-0063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/19/2023]
Abstract
BACKGROUND There is limited evidence on the comparative diagnostic performance of endoscopic tissue sampling techniques for subepithelial lesions. We performed a systematic review with network meta-analysis to compare these techniques. METHODS A systematic literature review was conducted for randomized controlled trials (RCTs) comparing the sample adequacy and diagnostic accuracy of bite-on-bite biopsy, mucosal incision-assisted biopsy (MIAB), endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and EUS-guided fine-needle biopsy (FNB). Results were expressed as relative risk (RR) and 95%CI. RESULTS Eight RCTs were identified. EUS-FNB was significantly superior to EUS-FNA in terms of sample adequacy (RR 1.20 [95%CI 1.05-1.45]), whereas none of the other techniques significantly outperformed EUS-FNA. Additionally, bite-on-bite biopsy was significantly inferior to EUS-FNB (RR 0.55 [95%CI 0.33-0.98]). Overall, EUS-FNB appeared to be the best technique (surface under cumulative ranking [SUCRA] score 0.90) followed by MIAB (SUCRA 0.83), whereas bite-on-bite biopsy showed the poorest performance. When considering lesions <20 mm, MIAB, but not EUS-FNB, showed significantly higher accuracy rates compared with EUS-FNA (RR 1.68 [95%CI 1.02-2.88]). Overall, MIAB ranked as the best intervention for lesions <20 mm (SUCRA score 0.86 for adequacy and 0.91 for accuracy), with EUS-FNB only slightly superior to EUS-FNA. When rapid on-site cytological evaluation (ROSE) was available, no difference between EUS-FNB, EUS-FNA, and MIAB was observed. CONCLUSION EUS-FNB and MIAB appeared to provide better performance, whereas bite-on-bite sampling was significantly inferior to the other techniques. MIAB seemed to be the best option for smaller lesions, whereas EUS-FNA remained competitive when ROSE was available.
Collapse
Affiliation(s)
- Antonio Facciorusso
- Gastroenterology Unit, Department of Surgical and Medical Sciences, University of Foggia, Foggia, Italy
| | - Stefano Francesco Crinò
- Gastroenterology and Digestive Endoscopy Unit, Department of Medicine, The Pancreas Institute, University Hospital of Verona, Verona, Italy
| | - Alessandro Fugazza
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Silvia Carrara
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Marco Spadaccini
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Matteo Colombo
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Daryl Ramai
- Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, United States
| | | | - Saurabh Chandan
- Division of Gastroenterology and Hepatology, CHI Creighton University Medical Center, Omaha, United States
| | - Paraskevas Gkolfakis
- Department of Gastroenterology, "Konstantopouleion-Patision" General Hospital of Nea Ionia, Athens, Greece
| | - Babu Mohan
- Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, United States
| | - Cesare Hassan
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Alessandro Repici
- Endoscopic Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| |
Collapse
|
5
|
Ishikawa T, Yamao K, Mizutani Y, Iida T, Kawashima H. Cutting edge of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions. J Med Ultrason (2001) 2023:10.1007/s10396-023-01375-y. [PMID: 37914883 DOI: 10.1007/s10396-023-01375-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 08/31/2023] [Indexed: 11/03/2023]
Abstract
This article provides an extensive review of the advancements and future perspectives related to endoscopic ultrasound-guided tissue acquisition (EUS-TA) for the diagnosis of solid pancreatic lesions (SPLs). EUS-TA, including fine-needle aspiration (EUS-FNA) and fine-needle biopsy (EUS-FNB), has revolutionized the collection of specimens from intra-abdominal organs, including the pancreas. Improvements in the design of needles, collection methods, and specimen processing techniques have improved the diagnostic performance. This review highlights the latest findings regarding needle evolution, actuation number, sampling methods, specimen evaluation techniques, application of artificial intelligence (AI) for diagnostic purposes, and use of comprehensive genomic profiling (CGP). It acknowledges the rising use of Franseen and fork-tip needles for EUS-FNB and emphasizes that the optimal number of actuations requires further study. Methods such as the door-knocking and fanning techniques have shown promise for increasing diagnostic performance. Macroscopic on-site evaluation (MOSE) is presented as a practical rapid specimen evaluation method, and the integration of AI is identified as a potentially impactful development. The study also underscores the importance of optimal sampling for CGP, which can enhance the precision of cancer treatment. Ongoing research and technological innovations will further improve the accuracy and efficacy of EUS-TA.
Collapse
Affiliation(s)
- Takuya Ishikawa
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8560, Japan.
| | - Kentaro Yamao
- Department of Endoscopy, Nagoya University Hospital, Nagoya, Japan
| | - Yasuyuki Mizutani
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8560, Japan
| | - Tadashi Iida
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8560, Japan
| | - Hiroki Kawashima
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8560, Japan
| |
Collapse
|
6
|
Ishikawa K, Ishiwatari H, Sasaki K, Niiya F, Satoh T, Sato J, Matsubayashi H, Minamide T, Yamamoto Y, Yoshida M, Maeda Y, Kawata N, Takada K, Kishida Y, Imai K, Hotta K, Notsu A, Ono H. Optimization of endoscopic ultrasound-guided tissue sample acquisition for commercially available comprehensive genome profiling. J Gastroenterol Hepatol 2023; 38:1794-1801. [PMID: 37495215 DOI: 10.1111/jgh.16304] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 06/12/2023] [Accepted: 07/08/2023] [Indexed: 07/28/2023]
Abstract
BACKGROUND AND AIM Optimal tumor samples are crucial for successful analysis using commercially available comprehensive genomic profiling (CACGP). However, samples acquired by endoscopic ultrasound-guided tissue acquisition (EUS-TA) are occasionally insufficient, and no consensus on the optimal number of needle passes required for CACGP exists. This study aimed to explore the optimal number of needle passes required for EUS-TA to procure an ideal sample fulfilling the prerequisite criteria of CACGPs. METHODS Patients who underwent EUS-TA for solid masses between November 2019 and July 2021 were retrospectively studied. The correlation between the acquisition rate of an ideal sample and the number of needle passes mounted on a microscope slide was evaluated. Additionally, the factors predicting a successful analysis were investigated in patients scheduled for CACGP using EUS-TA-obtained samples during the same period. RESULTS EUS-TAs using 22- and 19-gauge (G) needles were performed in 336 and 57 patients, respectively. There was a positive correlation between the acquisition rate and the number of passes using a 22-G needle (38.9%, 45.0%, 83.7%, and 100% for 1, 2, 3, and 4 passes, respectively), while no correlation was found with a 19-G needle (84.2%, 83.3%, and 85.0% for 1, 2, and 3 passes, respectively). The analysis success rate in patients with scheduled CACGP was significantly higher with ideal samples than with suboptimal samples (94.1% vs 55.0%, P < 0.01). CONCLUSIONS The optimal estimated number of needle passes was 4 and 1-2 for 22- and 19-G needles, respectively.
Collapse
Affiliation(s)
- Kazuma Ishikawa
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | | | - Keiko Sasaki
- Division of Pathology, Shizuoka Cancer Center, Shizuoka, Japan
| | - Fumitaka Niiya
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Tatsunori Satoh
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
- Department of Gastroenterology, Shizuoka General Hospital, Shizuoka, Japan
| | - Junya Sato
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Hiroyuki Matsubayashi
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
- Division of Genetic Counseling, Genetic Medicine Promotion, Shizuoka Cancer Center, Shizuoka, Japan
| | | | - Yoichi Yamamoto
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Masao Yoshida
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Yuki Maeda
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Noboru Kawata
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kazunori Takada
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | | | - Kenichiro Imai
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kinichi Hotta
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Akifumi Notsu
- Clinical Research Center, Shizuoka Cancer Center, Shizuoka, Japan
| | - Hiroyuki Ono
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| |
Collapse
|
7
|
Kataoka K, Ishikawa T, Ohno E, Yamao K, Mizutani Y, Iida T, Kato K, Kinoshita F, Yamamura T, Furukawa K, Nakamura M, Kawashima H. Randomized trial comparing 15 vs 5 actuations per pass during endoscopic ultrasound-guided fine-needle biopsy for specimen acquisition of solid pancreatic lesions. J Gastroenterol Hepatol 2023; 38:1647-1655. [PMID: 37328944 DOI: 10.1111/jgh.16258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 05/22/2023] [Accepted: 05/29/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND AIM There is currently no established number of actuations (to-and-fro movements) per pass during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). This study aimed to compare 15 vs 5 actuations in terms of adequate specimen acquisition of solid pancreatic lesions. METHODS In this prospective, randomized, crossover, noninferiority, single-center study, eligible patients underwent EUS-FNB using a 22-G Franseen needle with both 15 and 5 actuations per pass, performed in a randomized order, from October 2020 to December 2021. The acquired specimens from each pass were separately evaluated. The primary outcome was the accuracy of the histological diagnosis per pass. The noninferiority margin was set as 15%. RESULTS Data from 85 patients were analyzed, revealing pancreatic cancer in 73 patients. The accuracy of the histological diagnosis in the 15 and 5 actuations groups was 83.5% (71/85) and 77.7% (66/85), respectively. The difference was -5.8% (95% confidence interval -15.6-3.4), which does not indicate noninferiority of the five actuations group. Among the secondary outcomes, the 15 actuations group was significantly superior to the five actuations group in terms of the obtained core tissues (1.88 [interquartile range 0.89-3.64] mm2 vs 1.66 [0.83-2.71] mm2 [P = 0.031]) and subjective evaluation of cytology specimens for pancreatic cancer (69.0% vs. 31.0%, P = 0.005). CONCLUSIONS The noninferiority of five actuations in the accuracy of the histological diagnosis was not confirmed, and 15 actuations are preferred during EUS-FNB for solid pancreatic lesions.
Collapse
Affiliation(s)
- Kunio Kataoka
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Takuya Ishikawa
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Eizaburo Ohno
- Department of Gastroenterology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Kentaro Yamao
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Yasuyuki Mizutani
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Tadashi Iida
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Katsuyuki Kato
- Department of Pathology and Clinical Laboratories, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Fumie Kinoshita
- Data Coordinating Center, Department of Advanced Medicine, Nagoya University Hospital, Nagoya, Japan
| | - Takeshi Yamamura
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Kazuhiro Furukawa
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Masanao Nakamura
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hiroki Kawashima
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
8
|
Guan C, Wu M, Ye J, Liu Z, Mao Z, Lu C, Zhang J. Macroscopic on‑site quality evaluation of biopsy specimens to improve the diagnostic accuracy of endoscopic ultrasound‑guided fine needle aspiration using a 22‑gauge needle for solid lesions: A single‑center retrospective study. Exp Ther Med 2023; 26:338. [PMID: 37383379 PMCID: PMC10294598 DOI: 10.3892/etm.2023.12037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 05/03/2023] [Indexed: 06/30/2023] Open
Abstract
The present study aimed to evaluate the clinical value of macroscopic on-site evaluation (MOSE) of solid masses by endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) using a standard 22-gauge needle and to explore the cut-off length of macroscopic visible core (MVC) required to obtain an accurate histopathological diagnosis. In total, 119 patients who satisfied the inclusion and exclusion criteria and underwent EUS-FNA were divided into conventional FNA and FNA combined with MOSE groups. In the MOSE group, the presence of MVC was examined and its total length measured, after which the pathological results of FNA were compared with the final diagnosis. The diagnostic sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of FNA in the two groups were calculated and the effect of MOSE on the FNA result was analyzed. The MOSE group had a higher diagnostic sensitivity (75.0% vs. 89.8%; P=0.038) and accuracy (74.5% vs. 90.6%; P=0.026). MVC was observed in 98.4% (63/64) of patients in the MOSE group. The median length of MVC was 15 mm. The optimal cut-off length of MVC for obtaining an accurate histological diagnosis was 13 mm, with a sensitivity of 90.2%. No statistically significant significance was observed in the specificity, PPV and NPV between the groups. Thus, MOSE helps to improve the diagnostic ability of FNA for solid masses and may be a useful alternative to assess the adequacy of puncture specimens in units where rapid on-site evaluation cannot be performed.
Collapse
Affiliation(s)
- Chengqi Guan
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| | - Mengyu Wu
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
- Department of Gastroenterology, Maanshan People's Hospital, Manashan, Anhui 243000, P.R. China
| | - Jingxin Ye
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| | - Zhaoxiu Liu
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| | - Zhenbiao Mao
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| | - Cuihua Lu
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| | - Jianfeng Zhang
- Department of Gastroenterology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, P.R. China
| |
Collapse
|
9
|
Ishiwatari H. The role of macroscopic on-site evaluation in the era of biopsy needles: is it still useful? Endoscopy 2023; 55:138-139. [PMID: 36216265 DOI: 10.1055/a-1942-6382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
10
|
Franchellucci G, Andreozzi M, Carrara S, De Luca L, Auriemma F, Paduano D, Calabrese F, Facciorusso A, Poletti V, Zerbi A, Lania AG, Bertuzzi AF, Spaggiari P, Pedicini V, Rodari M, Fusaroli P, Lisotti A, Ofosu A, Repici A, Mangiavillano B. Contrast Enhanced EUS for Predicting Solid Pancreatic Neuroendocrine Tumor Grade and Aggressiveness. Diagnostics (Basel) 2023; 13. [PMID: 36673049 DOI: 10.3390/diagnostics13020239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/29/2022] [Accepted: 12/29/2022] [Indexed: 01/11/2023] Open
Abstract
Pancreatic neuroendocrine tumor (PNET) behavior assessment is a daily challenge for physicians. Modern PNET management varies from a watch-and-wait strategy to surgery depending on tumor aggressiveness. Therefore, the aggressiveness definition plays a pivotal role in the PNET work-up. The aggressiveness of PNETs is mainly based on the dimensions and histological grading, with sometimes a lack of specificity and sensibility. In the last twenty years, EUS has become a cornerstone in the diagnostic phase of PNET management for its high diagnostic yield and the possibility of obtaining a histological specimen. The number of EUS applications in the PNET work-up has been rapidly increasing with new and powerful possibilities. The application of contrast has led to an important step in PNET detection; in recent years, it has been gaining interesting applications in aggressiveness assessment. In this review, we underline the latest experiences and opportunities in the behavior assessment of PNETs using contact-enhanced EUS and contested enhanced harmonic EUS with a particular focus on the future application and possibility that these techniques could provide.
Collapse
|