1
|
Mathur VP, Duggal I, Atif M, Tewari N, Rahul M, Duggal R, Chawla A. Development and validation of risk of bias tool for the use of finite element analysis in dentistry (ROBFEAD). Comput Methods Biomech Biomed Engin 2023; 26:1822-1833. [PMID: 36475384 DOI: 10.1080/10255842.2022.2148465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 11/13/2022] [Indexed: 12/12/2022]
Abstract
There has been a systematic review of studies that used FEA in dental sciences, but no adequate risk of bias (RoB) analysis technique has been developed. Therefore, the development and validation process of RoB in studies using the finite element analysis in dentistry (ROBFEAD) tool is described. In the first phase of development, the scope of the tool and possible modifications were covered, and validation was done in the second phase. The developed tool comprised 6 domains and a total of 22 guiding questions in these domains. This article proposes the development and validation of ROBFEAD, a tool for measuring RoB in finite element research in dentistry.
Collapse
Affiliation(s)
- Vijay Prakash Mathur
- Pediatrics & Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Isha Duggal
- Orthodontics and Dentofacial Deformities, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Mohammad Atif
- Pediatrics & Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Nitesh Tewari
- Pediatrics & Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Morankar Rahul
- Pediatrics & Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Ritu Duggal
- Orthodontics and Dentofacial Deformities, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India
| | - Anoop Chawla
- Department of Mechanical Engineering, Indian Institute of Technology, New Delhi
| |
Collapse
|
2
|
Guo J, Chen J, Wang J, Ren G, Tian Q, Guo C. EMG-assisted forward dynamics simulation of subject-specific mandible musculoskeletal system. J Biomech 2022; 139:111143. [DOI: 10.1016/j.jbiomech.2022.111143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/17/2022] [Accepted: 05/09/2022] [Indexed: 01/17/2023]
|
3
|
Hawthan M, Chrcanovic BR, Larsson C, Leles CR. Retrospective Study Comparing Clinical Outcomes of Fixed Dental Prostheses in Matched Groups of Bruxer and Nonbruxer Patients. Int J Dent 2022; 2022:1-7. [PMID: 35386548 PMCID: PMC8977310 DOI: 10.1155/2022/6818170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/12/2022] [Indexed: 02/03/2023] Open
Abstract
Background Tooth-supported fixed dental prosthesis (FDP) is one of the most reliable treatment options to replace missing teeth. The longevity of the treatment could, however, be affected by several general and local factors, especially bruxism. Objective To investigate the influence of bruxism on the long-term survival of tooth-supported FDPs in bruxers compared to a matched group of nonbruxers, taking several clinical variables into account. Materials and Methods The present retrospective cohort study was based on records of patients treated with 3–7-unit tooth-supported FDPs with a minimum follow-up time of 6 months after prosthesis delivery. The criteria for the diagnosis of “possible” and “probable” sleep or awake bruxism were used. A matched group of nonbruxers was selected on the basis of similarities in four factors, patients' gender and age, number of prosthetic units of the FDPs, and follow-up time. The paired-samples t-test or Wilcoxon signed rank test were used to compared mean values between the two groups. Contingency tables of categorical data were analyzed by McNemar's test. Results The cohort group consisted of 62 noncantilevered FDPs in each group, followed up for a mean of 110.1 and 106.5 months (bruxers and nonbruxers, respectively). Tooth-supported FDPs in bruxers presented significantly higher failure rate than in nonbruxers (32.3% vs. 25.8%, respectively; p = 0.001). Loss of retention and tooth loss were the main reasons for failures in both groups. For nonsmokers, the FDP failure rate was higher in nonbruxers. Technical and biological complications were significantly more prevalent in bruxers compared to nonbruxers. Conclusions Bruxism is suggested to increase technical and biological complications and FDP failure.
Collapse
|
4
|
Xu S, Zhang G, Guo JF, Tan YH. Helmet chinstrap protective role in maxillofacial blast injury. Technol Health Care 2021; 29:735-747. [PMID: 33522988 DOI: 10.3233/thc-202406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The protective role of helmet accessories in moderating stress load generated by explosion shock waves of explosive devices is usually neglected. OBJECTIVE In the presented study, the protective role of the helmet chinstrap against the impulse and overpressure experienced by the maxillofacial region were examined. METHODS The explosion shock wave and skull interaction were investigated under three different configurations: (1) unprotected skull, (2) skull with helmet (3) skull with helmet and chinstrap. For this purpose, a 3D finite element model (FEM) was constructed to mimic the investigated biomechanics module. Three working conditions were set according to different explosive charges and distances to represent different load conditions. Case 1: 500 mg explosive trinitrotoluene (TNT), 3 cm, case 2: 1000 mg TNT, 3 cm, and case 3: 1000 mg TNT and 6 cm distance to the studied object. The explosion effect was discussed by examining the shock wave stress flow pattern. Three points were selected on the skull and the stress curve of each point position were illustrated for each case study. RESULTS The results showed that the helmet chinstrap can reduce the explosive injuries and plays a protective role in the maxillofacial region, especially for the mandible.
Collapse
|
5
|
Woodford SC, Robinson DL, Edelmann C, Mehl A, Röhrle O, Vee Sin Lee P, Ackland DC. Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading. Ann Biomed Eng 2021; 49:1561-1571. [PMID: 33409850 DOI: 10.1007/s10439-020-02688-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 11/04/2020] [Indexed: 11/30/2022]
Abstract
Dynamic occlusal loading during mastication is clinically relevant in the design and functional assessment of dental restorations and removable dentures, and in evaluating temporomandibular joint dysfunction. The aim of this study was to develop a modelling framework to evaluate subject-specific dynamic occlusal loading during chewing and biting over the entire dental arch. Measurements of jaw motion were performed on one healthy male adult using low-profile electromagnetic field sensors attached to the teeth, and occlusal anatomy quantified using an intra-oral scanner. During testing, the subject chewed and maximally compressed a piece of rubber between both second molars, first molars, premolars and their central incisors. The occlusal anatomy, rubber geometry and experimentally measured rubber material properties were combined in a finite element model. The measured mandibular motion was used to kinematically drive model simulations of chewing and biting of the rubber sample. Three-dimensional dynamic bite forces and contact pressures across the occlusal surfaces were then calculated. Both chewing and biting on the first molars produced the highest bite forces across the dental arch, and a large amount of anterior shear force was produced at the incisors and the second molars. During chewing, the initial tooth-rubber contact evolved from the buccal sides of the molars to the lingual sides at full mouth closure. Low-profile electromagnetic field sensors were shown to provide a clinically relevant measure of jaw kinematics with sufficient accuracy to drive finite element models of occlusal loading during chewing and biting. The modelling framework presented provides a basis for calculation of physiological, dynamic occlusal loading across the dental arch.
Collapse
Affiliation(s)
- Sarah C Woodford
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Dale L Robinson
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - Cornelia Edelmann
- Centre of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Albert Mehl
- Centre of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Oliver Röhrle
- Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany
| | - Peter Vee Sin Lee
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, 3010, Australia.
| |
Collapse
|
6
|
Kang X, Li Y, Wang Y, Zhang Y, Yu D, Peng Y. Relationships of Stresses on Alveolar Bone and Abutment of Dental Implant from Various Bite Forces by Three-Dimensional Finite Element Analysis. Biomed Res Int 2020; 2020:7539628. [PMID: 32149132 DOI: 10.1155/2020/7539628] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2019] [Revised: 12/02/2019] [Accepted: 01/23/2020] [Indexed: 11/24/2022]
Abstract
Occlusal trauma caused by improper bite forces owing to the lack of periodontal membrane may lead to bone resorption, which is still a problem for the success of dental implant. In our study, to avoid occlusal trauma, we put forward a hypothesis that a microelectromechanical system (MEMS) pressure sensor is settled on an implant abutment to track stress on the abutment and predict the stress on alveolar bone for controlling bite forces in real time. Loading forces of different magnitudes (0 N–100 N) and angles (0–90°) were applied to the crown of the dental implant of the left central incisor in a maxillary model. The stress distribution on the abutment and alveolar bone were analyzed using a three-dimensional finite element analysis (3D FEA). Then, the quantitative relation between them was derived using Origin 2017 software. The results show that the relation between the loading forces and the stresses on the alveolar bone and abutment could be described as 3D surface equations associated with the sine function. The appropriate range of stress on the implant abutment is 1.5 MPa–8.66 MPa, and the acceptable loading force range on the dental implant of the left maxillary central incisor is approximately 6 N–86 N. These results could be used as a reference for the layout of MEMS pressure sensors to maintain alveolar bone dynamic remodeling balance.
Collapse
|
7
|
Woodford SC, Robinson DL, Mehl A, Lee PVS, Ackland DC. Measurement of normal and pathological mandibular and temporomandibular joint kinematics: A systematic review. J Biomech 2020; 111:109994. [PMID: 32971491 DOI: 10.1016/j.jbiomech.2020.109994] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 07/27/2020] [Accepted: 08/08/2020] [Indexed: 01/08/2023]
Abstract
Motion of the mandible and temporomandibular joint (TMJ) plays a pivotal role in the function of the dentition and associated hard and soft tissue structures, and facilitates mastication, oral communication and access to respiratory and digestive systems. Quantification of TMJ kinematics is clinically relevant in cases of prosthetic rehabilitations, TMJ disorders, osteoarthritis, trauma, tumour resection and congenital abnormalities, which are known to directly influence mandibular motion and loading. The objective of this systematic review was to critically investigate published literature on historic and contemporary measurement modalities used to quantify in vivo mandibular and TMJ kinematics in six degrees of freedom. The electronic databases of Scopus, Web of Science, Medline, Embase and Central were searched and 109 relevant articles identified. Publication quality was documented using a modified Downs and Black checklist. Axiography and ultrasonic tracking are commonly employed in the clinical setting due to their simplicity and capacity to rapidly acquire low-fidelity mandibular motion data. Magnetic and optoelectronic tracking have been used in combination with dental splints to produce higher accuracy measurements while minimising skin motion artefact, but at the expense of setup time and cost. Four-dimensional computed tomography provides direct 3D measurement of mandibular and TMJ motion while circumventing skin motion artefact entirely, but employs ionising radiation, is restricted to low sampling frequencies, and requires time-consuming image processing. Recent advances in magnetic tracking using miniature sensors adhered to the teeth in combination with intraoral scanning may facilitate rapid and high precision mandibular kinematics measurement in the clinical setting. The findings of this review will guide selection and application of mandibular and TMJ kinematic measurement for both clinical and research applications.
Collapse
Affiliation(s)
- Sarah C Woodford
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Dale L Robinson
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - Albert Mehl
- Centre of Dental Medicine, University of Zürich, Zürich, Switzerland
| | - Peter V S Lee
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia.
| |
Collapse
|
8
|
Saini H, Ackland DC, Gong L, Cheng, Röhrle O. Occlusal load modelling significantly impacts the predicted tooth stress response during biting: a simulation study. Comput Methods Biomech Biomed Engin 2020; 23:261-270. [PMID: 31965827 DOI: 10.1080/10255842.2020.1711886] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Computational models of the masticatory system can provide estimates of occlusal loading during (static) biting or (dynamic) chewing and therefore can be used to evaluate and optimize functional performance of prosthodontic devices and guide dental surgery planning. The modelling assumptions, however, need to be chosen carefully in order to obtain meaningful predictions. The objectives of this study were two-fold: (i) develop a computational model to calculate the stress response of the first molar during biting of a rubber sample and (ii) evaluate the influence of different occlusal load models on the stress response of dental structures. A three-dimensional finite element model was developed comprising the mandible, first molar, associated dental structures, and the articular fossa and discs. Simulations of a maximum force bite on a rubber sample were performed by applying muscle forces as boundary conditions on the mandible and computing the contact between the rubber and molars (GS case). The molar occlusal force was then modelled as a single point force (CF1 case), four point forces (CF2 case), and as a sphere compressing against the occlusal surface (SL case). The peak enamel stress for the GS case was 110 MPa and 677 MPa, 270 MPa and 305 MPa for the CF1, CF2 and SL cases, respectively. Peak dentin stress for the GS case was 44 MPa and 46 MPa, 50 MPa and 63 MPa for the CF1, CF2 and SL cases, respectively. Furthermore, the enamel stress distribution was also strongly correlated to the occlusal load model. The way in which occlusal load is modelled has a substantial influence on the stress response of enamel during biting, but has relatively little impact on the behavior of dentin. The use of point forces or sphere contact to model occlusal loading during mastication overestimates enamel stress magnitude and also influences enamel stress distribution.
Collapse
Affiliation(s)
- Harnoor Saini
- Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - Lulu Gong
- School of Life Sciences and Technology, Tongji University, Shanghai, P.R. China
| | - Cheng
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.,Riddet Institute, Palmerston North, New Zealand
| | - Oliver Röhrle
- Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany.,Stuttgart Center of Simulation Science (SC SimTech), University of Stuttgart, Stuttgart, Germany.,Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA, Stuttgart, Germany
| |
Collapse
|
9
|
Robinson D, Aguilar L, Gatti A, Abduo J, Lee PVS, Ackland D. Load response of the natural tooth and dental implant: A comparative biomechanics study. J Adv Prosthodont 2019; 11:169-178. [PMID: 31297176 PMCID: PMC6609758 DOI: 10.4047/jap.2019.11.3.169] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 05/11/2019] [Accepted: 06/11/2019] [Indexed: 11/23/2022] Open
Abstract
PURPOSE While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible (1.8 mε, −1.7 mε) were lower than those observed at the prosthetic tooth (12.5 MPa, 3.2 mε, and −4.4 mε, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.
Collapse
Affiliation(s)
- Dale Robinson
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - Luis Aguilar
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - Andrea Gatti
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - Jaafar Abduo
- Melbourne Dental Shool, University of Melbourne, Victoria, Australia
| | - Peter Vee Sin Lee
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| | - David Ackland
- Department of Biomedical Engineering, University of Melbourne, Victoria, Australia
| |
Collapse
|