1
|
Chung CR, Ko RE, Jang GY, Lee K, Suh GY, Kim Y, Woo EJ. Comparison of noninvasive cardiac output and stroke volume measurements using electrical impedance tomography with invasive methods in a swine model. Sci Rep 2024; 14:2962. [PMID: 38316842 PMCID: PMC10844629 DOI: 10.1038/s41598-024-53488-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 02/01/2024] [Indexed: 02/07/2024] Open
Abstract
Pulmonary artery catheterization (PAC) has been used as a clinical standard for cardiac output (CO) measurements on humans. On animals, however, an ultrasonic flow sensor (UFS) placed around the ascending aorta or pulmonary artery can measure CO and stroke volume (SV) more accurately. The objective of this paper is to compare CO and SV measurements using a noninvasive electrical impedance tomography (EIT) device and three invasive devices using UFS, PAC-CCO (continuous CO) and arterial pressure-based CO (APCO). Thirty-two pigs were anesthetized and mechanically ventilated. A UFS was placed around the pulmonary artery through thoracotomy in 11 of them, while the EIT, PAC-CCO and APCO devices were used on all of them. Afterload and contractility were changed pharmacologically, while preload was changed through bleeding and injection of fluid or blood. Twenty-three pigs completed the experiment. Among 23, the UFS was used on 7 pigs around the pulmonary artery. The percentage error (PE) between COUFS and COEIT was 26.1%, and the 10-min concordance was 92.5%. Between SVUFS and SVEIT, the PE was 24.8%, and the 10-min concordance was 94.2%. On analyzing the data from all 23 pigs, the PE between time-delay-adjusted COPAC-CCO and COEIT was 34.6%, and the 10-min concordance was 81.1%. Our results suggest that the performance of the EIT device in measuring dynamic changes of CO and SV on mechanically-ventilated pigs under different cardiac preload, afterload and contractility conditions is at least comparable to that of the PAC-CCO device. Clinical studies are needed to evaluate the utility of the EIT device as a noninvasive hemodynamic monitoring tool.
Collapse
Affiliation(s)
- Chi Ryang Chung
- Department of Critical Care Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ryoung Eun Ko
- Department of Critical Care Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Geuk Young Jang
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Korea
| | - Kyounghun Lee
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Korea
| | - Gee Young Suh
- Department of Critical Care Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yongmin Kim
- Department of Convergence IT Engineering, POSTECH, Pohang, Korea
| | - Eung Je Woo
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Korea.
| |
Collapse
|
2
|
Zhang Y, Zhu Y, Wang D, Xu L, Jiang W, Wang J, Sun X, Kang L, Song L. Cardiac index: A superior parameter of cardiac function than left ventricular ejection fraction in risk stratification of hypertrophic cardiomyopathy. Heart Rhythm 2023:S1547-5271(23)00212-6. [PMID: 36870381 DOI: 10.1016/j.hrthm.2023.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 02/18/2023] [Accepted: 02/25/2023] [Indexed: 03/06/2023]
Abstract
BACKGROUND An appropriate indicator of cardiac function in the risk stratification of hypertrophic cardiomyopathy (HCM) patients is urgently needed. Cardiac index that reflects cardiac pumping function may be suitable. OBJECTIVE The purpose of this study was to investigate the clinical significance of reduced cardiac index in HCM patients. METHODS A total of 927 HCM patients were enrolled. The primary endpoint was cardiovascular death. The secondary endpoints were sudden cardiac death (SCD) and all-cause death. Combination models were constructed by adding reduced cardiac index and reduced left ventricular ejection fraction (LVEF) to the HCM risk-SCD model. Predictive accuracy was determined by C-statistics. RESULTS Reduced cardiac index was defined as cardiac index ≤2.42 L/min/m2. During median follow-up of 4.3 years, 51 patients reached the endpoint. Reduced cardiac index independently increased the risk of cardiovascular death (adjusted hazard ratio [aHR] 2.976; P = .007), SCD (aHR 6.385; P = .001), and all-cause death (aHR 2.428; P = .010). By adding reduced cardiac index to the HCM risk-SCD model, the model C-statistic increased from 0.691 to 0.762, with an integrated discrimination improvement of 0.021 (P = .018) and a net reclassification improvement of 0.560 (P = .007). The addition of reduced LVEF failed to improve the original model. Better predictive accuracy for all endpoints was also indicated in reduced cardiac index than in reduced LVEF. CONCLUSION Reduced cardiac index is an independent predictor of poor prognoses in HCM patients. Combining reduced cardiac index rather than reduced LVEF improved the HCM risk-SCD stratification strategy. The reduced cardiac index showed better predictive accuracy than reduced LVEF for all endpoints.
Collapse
Affiliation(s)
- Yu Zhang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuming Zhu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Dong Wang
- Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Lianjun Xu
- Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wen Jiang
- Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jizheng Wang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xiaolu Sun
- Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| | - Lianming Kang
- Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| | - Lei Song
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; Cardiomyopathy Ward, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; National Clinical Research Center of Cardiovascular Diseases, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
3
|
Jang GY, Chung CR, Ko RE, Lee JY, Oh TI, Suh GY, Kim Y, Woo EJ. Real-Time Measurements of Relative Tidal Volume and Stroke Volume Using Electrical Impedance Tomography with Spatial Filters: A Feasibility Study in a Swine Model Under Normal and Reduced Ventilation. Ann Biomed Eng 2023; 51:394-409. [PMID: 35960417 DOI: 10.1007/s10439-022-03040-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 07/28/2022] [Indexed: 01/25/2023]
Abstract
Continuous monitoring of both hemodynamic and respiratory parameters would be beneficial to patients, e.g., those in intensive care unit. The objective of this exploratory animal study was to test the feasibility of simultaneous measurements of relative tidal volume (rTV) and relative stroke volume (rSV) using an electrical impedance tomography (EIT) device equipped with a new real-time source separation algorithm implemented as two spatial filters. Five pigs were anesthetized and mechanically ventilated. The supplied tidal volume from a mechanical ventilator was reduced to 70, 50 and 30% from the 100% normal volume to simulate hypoventilation. The respiratory volume signal and cardiac volume signal were generated by applying the spatial filters to the acquired EIT data, from which values of rTV and rSV were extracted. The measured rTV values were compared with the TV values from the mechanical ventilator using the four-quadrant concordance analysis method. For changes in TV, the concordance rate in each animal ranged from 81.8% to 100%, while it was 92.5% when the data from all five animals were pooled together. When the measured rTV values for each animal were scaled to the absolute TVEIT values in mL using the TVVent data from the mechanical ventilator, the smallest 95% limits of agreement (LoA) were - 6.04 and 7.44 mL for the 70% ventilation level, and the largest 95% LoA were - 18.1 and 19.4 mL for the 50% ventilation level. The percentage error between TVEIT and TVVent was 10.3%. Although similar statistical analyses on rSV data could not be performed due to limited intra-animal variability, changes in rSV values measured by the EIT device were comparable to those measured by an invasive hemodynamic monitor. In this animal study, we were able to demonstrate the feasibility of an EIT device for noninvasive and simultaneous measurements of rTV and rSV in real time. However, the performance of the real-time source separation method needs to be further validated on animals and human subjects, particularly over a wide range of SV values. Future clinical studies are needed to assess the potential usefulness of the new method in dynamic cardiopulmonary monitoring and explore other clinical applications.
Collapse
|
4
|
Lai Y, Lai W, Huang P, Hsiao T. Time- and Frequency-Domain Analysis of Stroke Volume Variability Using Indoor Cycling to Evaluate Physical Load of Body. Information 2022; 13:148. [DOI: 10.3390/info13030148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
A potential myocardial injury can be induced by intensive sporting activities, which may be due to ventricular tachycardia or fibrillation when individuals continue to exercise during the maximum physical loading period (the aerobic capability plateau, ACP). Herein, we conducted an incremental exercise test with the RR-interval and SV-series measurements as the input and output of the circulatory system. Through time and frequency analyses, we aimed to identify the indicators for distinguishing the normal stage (S1), last stage before ACP (S2), and ACP stage (S3) during different incremental physical loads. The cross-correlation results of the RR interval and SV series showed that the maximum coefficient of S2 was significantly greater (p < 0.05) than that of S1 (median 0.91 to 0.87), and also significantly lower (p < 0.05) than that of S3 (median 0.87 to 0.60). The corresponding spectrum shows that the decreasing correlation coefficient of SVV and Heart rate variability can be used to assess whether the body has reached the ACP. These findings can be used as a guide for exercise healthcare. Pausing or reducing the exercise load before entering the ACP could effectively reduce the risk of myocardial injury.
Collapse
|
5
|
Lee K, Jang GY, Kim Y, Woo EJ. Multi-channel Trans-impedance Leadforming for Cardiopulmonary Monitoring: Algorithm Development and Feasibility Assessment using In Vivo Animal Data. IEEE Trans Biomed Eng 2021; 69:1964-1974. [PMID: 34855581 DOI: 10.1109/tbme.2021.3132012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE The objectives of this study were to (1) develop a multi-channel trans-impedance leadforming method for beat-to-beat stroke volume (SV) and breath-by-breath tidal volume (TV) measurements and (2) assess its feasibility on an existing in vivo animal dataset. METHODS A deterministic leadforming algorithm was developed to extract a cardiac volume signal (CVS) and a respiratory volume signal (RVS) from 208-channel trans-impedance data acquired every 20 ms by an electrical impedance tomography (EIT) device. SVEIT and TVEIT values were computed as a valley-to-peak value in the CVS and RVS, respectively. The method was applied to the existing dataset from five mechanically-ventilated pigs undergoing ten mini-fluid challenges. An invasive hemodynamic monitor was used in the arterial pressure-based cardiac output (APCO) mode to simultaneously measure SVAPCO values while a mechanical ventilator provided TVVent values. RESULTS The leadforming method could reliably extract the CVS and RVS from the 208-channel trans-impedance data measured with the EIT device, from which SV<sub>EIT</sub> and TV<sub>EIT</sub> were computed. The SV<sub>EIT</sub> and TV<sub>EIT</sub> values were comparable to those from the invasive hemodynamic monitor and mechanical ventilator. Using the data from 5 pigs and a simple calibration method to remove bias, the error in SV<sub>EIT<sub> and TV<sub>EIT<sub> was 9.5% and 5.4%, respectively. CONCLUSION We developed a new leadforming method for the EIT device to robustly extract both SV and TV values in a deterministic fashion. Future animal and clinical studies are needed to validate this leadforming method in various subject populations. SIGNIFICANCE The leadforming method could be an integral component for a new cardiopulmonary monitor in the future to simultaneously measure SV and TV noninvasively, which would be beneficial to patients.
Collapse
|
6
|
Weissbach A. Authors' Response to a Letter to the Editor. Pediatr Cardiol 2021; 42:983-4. [PMID: 33835231 DOI: 10.1007/s00246-021-02605-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 04/01/2021] [Indexed: 10/21/2022]
|
7
|
Abstract
PURPOSE OF REVIEW Bedside cardiac output (CO) measurement is an important part of routine hemodynamic monitoring in the differential diagnosis of circulatory shock and fluid management. Different choices of CO measurement devices are available. The purpose of this review is to review the importance of CO [or stroke volume (SV)] measurement and to discuss the various methods (devices) used in determination of CO. RECENT FINDINGS CO measurement devices can be classified into two types: those use simple physical principles with minimal assumptions, and those predicting CO via mathematical modelling with a number of assumptions. Both have pros and cons, with the former being more accurate but with limited continuous monitoring capability whereas the latter less accurate but usually equipped with continuous monitoring functionality. With frequent updates in mathematical models, research data constantly become outdated in this area. Recent data suggest devices based on mathematical modelling have limited accuracies and poor precisions. SUMMARY Measurement of CO or SV is important in critically ill patients. Most devices have accuracy and reliability issues. The choice of device should depend on the purpose of measurement. For diagnostic purposes, devices based on simple physical principles, especially thermodilution and transthoracic echocardiography are more reliable due to accuracy.
Collapse
|
8
|
Sanders M, Servaas S, Slagt C. Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis. J Clin Monit Comput 2019; 34:433-460. [PMID: 31175501 PMCID: PMC7205855 DOI: 10.1007/s10877-019-00330-y] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 05/29/2019] [Indexed: 12/14/2022]
Abstract
Cardiac output monitoring is used in critically ill and high-risk surgical patients. Intermittent pulmonary artery thermodilution and transpulmonary thermodilution, considered the gold standard, are invasive and linked to complications. Therefore, many non-invasive cardiac output devices have been developed and studied. One of those is electrical cardiometry. The results of validation studies are conflicting, which emphasize the need for definitive validation of accuracy and precision. We performed a database search of PubMed, Embase, Web of Science and the Cochrane Library of Clinical Trials to identify studies comparing cardiac output measurement by electrical cardiometry and a reference method. Pooled bias, limits of agreement (LoA) and mean percentage error (MPE) were calculated using a random-effects model. A pooled MPE of less than 30% was considered clinically acceptable. A total of 13 studies in adults (620 patients) and 11 studies in pediatrics (603 patients) were included. For adults, pooled bias was 0.03 L min-1 [95% CI - 0.23; 0.29], LoA - 2.78 to 2.84 L min-1 and MPE 48.0%. For pediatrics, pooled bias was - 0.02 L min-1 [95% CI - 0.09; 0.05], LoA - 1.22 to 1.18 L min-1 and MPE 42.0%. Inter-study heterogeneity was high for both adults (I2 = 93%, p < 0.0001) and pediatrics (I2 = 86%, p < 0.0001). Despite the low bias for both adults and pediatrics, the MPE was not clinically acceptable. Electrical cardiometry cannot replace thermodilution and transthoracic echocardiography for the measurement of absolute cardiac output values. Future research should explore it's clinical use and indications.
Collapse
Affiliation(s)
- M Sanders
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - S Servaas
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - C Slagt
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands.
| |
Collapse
|