Objective neuromodulation basis for intrafascicular artificial somatosensation through carbon nanotube yarn electrodes.
J Neurosci Methods 2022;
369:109481. [PMID:
35032498 DOI:
10.1016/j.jneumeth.2022.109481]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 12/13/2021] [Accepted: 01/10/2022] [Indexed: 11/20/2022]
Abstract
BACKGROUND
Intrafascicular electrical stimulation has been extensively adopted to achieve sensory feedback for limb amputees. Axon-like carbon nanotube yarn (CNTy) electrodes with both promising flexibility and spatial selectivity index (SSI) can be fascinating alternatives to generate artificial somatosensation.
NEW METHOD
Here we systematically disclose objective neuromodulation basis for artificial somatosensation through intrafascicular CNTy electrodes. CNTy electrodes with different exposed lengths were utilized for electrically stimulating tibial nerves in twelve rats. Somatosensory evoked potentials (SEPs) were recorded synchronously using an epidural thirty-channel electrode array. Spatiotemporal characteristics of SEPs were analyzed as current pulse amplitude (PA), pulse width (PW) and pulse frequency (PF) varied.
RESULTS
The current thresholds at 1Hz exhibit the lowest means when compared with those at 4 and 8Hz for most CNTy electrodes (20/28). For all the electrodes, amplitudes of SEPs and activated areas of perceptive fields increase with PWs and PAs rising, and decrease remarkably with PFs from 1 to 8Hz. Latencies of P1 and N1 of SEP peaks gradually reduced with PWs and PAs advancing. Considering high SSIs, relatively stable current thresholds, wider variation ranges of sensory magnitudes and optimal stability of perceptive fields, the L-200 μm electrodes are preferable for neuromodulation with PFs of 1 - 8Hz, PWs of 100 - 800 μs and PAs of 2 - 64 μA.
COMPARISON WITH EXISTING METHODS
New-type CNTy electrodes possess both promising flexibility and SSI when compared with other neural interfaces. We systematically explore objective neuromodulation basis for artificial somatosensation through CNTy electrodes for the first time.
CONCLUSIONS
Significantly higher SSIs, lower current and charge thresholds exist for CNTy electrodes in comparison with other peripheral-nerve interfaces. This study can, for the first time, lay a solid neuromodulation foundation for CNTy electrodes to achieve fine sensory feedback.
Collapse