Lai K, Wang X, Cao C. A Continuous Non-Invasive Blood Pressure Prediction Method Based on Deep Sparse Residual U-Net Combined with Improved Squeeze and Excitation Skip Connections. Sensors (Basel) 2024; 24:2721. [PMID: 38732827 PMCID: PMC11086107 DOI: 10.3390/s24092721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 04/09/2024] [Accepted: 04/19/2024] [Indexed: 05/13/2024]
Abstract
Arterial blood pressure (ABP) serves as a pivotal clinical metric in cardiovascular health assessments, with the precise forecasting of continuous blood pressure assuming a critical role in both preventing and treating cardiovascular diseases. This study proposes a novel continuous non-invasive blood pressure prediction model, DSRUnet, based on deep sparse residual U-net combined with improved SE skip connections, which aim to enhance the accuracy of using photoplethysmography (PPG) signals for continuous blood pressure prediction. The model first introduces a sparse residual connection approach for path contraction and expansion, facilitating richer information fusion and feature expansion to better capture subtle variations in the original PPG signals, thereby enhancing the network's representational capacity and predictive performance and mitigating potential degradation in the network performance. Furthermore, an enhanced SE-GRU module was embedded in the skip connections to model and weight global information using an attention mechanism, capturing the temporal features of the PPG pulse signals through GRU layers to improve the quality of the transferred feature information and reduce redundant feature learning. Finally, a deep supervision mechanism was incorporated into the decoder module to guide the lower-level network to learn effective feature representations, alleviating the problem of gradient vanishing and facilitating effective training of the network. The proposed DSRUnet model was trained and tested on the publicly available UCI-BP dataset, with the average absolute errors for predicting systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) being 3.36 ± 6.61 mmHg, 2.35 ± 4.54 mmHg, and 2.21 ± 4.36 mmHg, respectively, meeting the standards set by the Association for the Advancement of Medical Instrumentation (AAMI), and achieving Grade A according to the British Hypertension Society (BHS) Standard for SBP and DBP predictions. Through ablation experiments and comparisons with other state-of-the-art methods, the effectiveness of DSRUnet in blood pressure prediction tasks, particularly for SBP, which generally yields poor prediction results, was significantly higher. The experimental results demonstrate that the DSRUnet model can accurately utilize PPG signals for real-time continuous blood pressure prediction and obtain high-quality and high-precision blood pressure prediction waveforms. Due to its non-invasiveness, continuity, and clinical relevance, the model may have significant implications for clinical applications in hospitals and research on wearable devices in daily life.
Collapse
Affiliation(s)
- Kaixuan Lai
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Xusheng Wang
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Congjun Cao
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| |
Collapse
|
2
|
Fang H, Xiong J, He L. Fair non-contact blood pressure estimation using imaging photoplethysmography. Biomed Opt Express 2024; 15:2133-2151. [PMID: 38633076 PMCID: PMC11019696 DOI: 10.1364/boe.514241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 02/15/2024] [Accepted: 02/28/2024] [Indexed: 04/19/2024]
Abstract
Hypertension is typically manifested as a latent symptom that requires detection through specialized equipment. This poses an inconvenience for individuals who need to undergo long-term blood pressure monitoring in their daily lives. Therefore, there is a need for a portable, non-contact method for estimating blood pressure. However, current non-contact blood pressure estimation methods often rely on relatively narrow datasets, lacking a broad range of blood pressure distributions. Additionally, their applicability is confined to controlled experimental environments. This study proposes a non-contact blood pressure estimation method suitable for various life scenarios, encompassing multiple age groups, diverse ethnicities, and individuals with different skin tones. The aim is to enhance the practicality and accuracy of existing non-contact blood pressure estimation methods. The research extracts the imaging photoplethysmogram (IPPG) signal from facial videos and processes the signal through four layers of filtering operations to obtain an IPPG signal reflecting pulse wave variations. A CNN+BiLSTM+GRU network structure is constructed to improve the accuracy of current non-contact blood pressure estimation methods. In comparison to existing approaches, the mean absolute error (MAE) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) is reduced by 13.6% and 16.4%, respectively.
Collapse
Affiliation(s)
- Hongli Fang
- College of Physics and Electronic Information Engineering, Zhejiang Normal University, Jinhua 321000, China
| | - Jiping Xiong
- College of Physics and Electronic Information Engineering, Zhejiang Normal University, Jinhua 321000, China
| | - Linying He
- College of Physics and Electronic Information Engineering, Zhejiang Normal University, Jinhua 321000, China
| |
Collapse
|
3
|
Fácila Rubio L, Lozano-Granero C, Vidal-Pérez R, Barrios V, Freixa-Pamias R. New technologies for the diagnosis, treatment, and monitoring of cardiovascular diseases. Rev Esp Cardiol (Engl Ed) 2024; 77:88-96. [PMID: 37838182 DOI: 10.1016/j.rec.2023.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 07/20/2023] [Indexed: 10/16/2023]
Abstract
Telemedicine enables the remote provision of medical care through information and communication technologies, facilitating data transmission, patient participation, promotion of heart-healthy habits, diagnosis, early detection of acute decompensation, and monitoring and follow-up of cardiovascular diseases. Wearable devices have multiple clinical applications, ranging from arrhythmia detection to remote monitoring of chronic diseases and risk factors. Integrating these technologies safely and effectively into routine clinical practice will require a multidisciplinary approach. Technological advances and data management will increase telemonitoring strategies, which will allow greater accessibility and equity, as well as more efficient and accurate patient care. However, there are still unresolved issues, such as identifying the most appropriate technological infrastructure, integrating these data into medical records, and addressing the digital divide, which can hamper patients' adoption of remote care. This article provides an updated overview of digital tools for a more comprehensive approach to atrial fibrillation, heart failure, risk factors, and treatment adherence.
Collapse
Affiliation(s)
- Lorenzo Fácila Rubio
- Servicio de Cardiología, Consorcio Hospital General Universitario de Valencia, Universitat de València, Valencia, Spain.
| | - Cristina Lozano-Granero
- Servicio de Cardiología, Hospital Universitario Ramón y Cajal y Centro de Investigación en Red de Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain
| | - Rafael Vidal-Pérez
- Servicio de Cardiología, Complejo Hospitalario Universitario de A Coruña, A Coruña, Spain
| | - Vivencio Barrios
- Servicio de Cardiología, Hospital Universitario Ramón y Cajal, Universidad de Alcalá (UAH), Madrid, Spain
| | - Román Freixa-Pamias
- Servicio de Cardiología, Complex Hospitalari Moisès Broggi, Sant Joan Despí, Barcelona, Spain
| |
Collapse
|
4
|
Alam J, Khan MF, Khan MA, Singh R, Mundazeer M, Kumar P. A Systematic Approach Focused on Machine Learning Models for Exploring the Landscape of Physiological Measurement and Estimation Using Photoplethysmography (PPG). J Cardiovasc Transl Res 2023:10.1007/s12265-023-10462-x. [PMID: 38010481 DOI: 10.1007/s12265-023-10462-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/08/2023] [Indexed: 11/29/2023]
Abstract
A non-invasive optical technique known as photoplethysmography (PPG) can be used to provide various physiological measurements and estimations. PPG can be used to assess cardiovascular disease (CVD). Hypertension is a primary risk factor for CVD and a major health problem worldwide. PPG is popular because of its important applications in the evaluation of cardiac activity, variations in venous blood volume, blood oxygen saturation, blood pressure and heart rate variability, etc. In this study, we provide a comprehensive analysis of the extraction of various physiological parameters using PPG waveforms. In addition, we focused on the role of machine learning (ML) models used for the estimation of blood pressure and hypertension classification based on PPG waveforms to make future research and innovation recommendations. This study will be helpful for researchers, scientists, and medical practitioners working on PPG waveforms for monitoring, screening, and diagnosis, as a comparative study or reference.
Collapse
Affiliation(s)
- Javed Alam
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates.
| | | | - Meraj Alam Khan
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
- DigiBiomics Inc, Mississauga, Ontario, Canada
| | - Rinky Singh
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
| | | | - Pramod Kumar
- Quantlase Lab LLC, Masdar City, Abu Dhabi, United Arab Emirates
| |
Collapse
|
5
|
Mahardika T NQ, Fuadah YN, Jeong DU, Lim KM. PPG Signals-Based Blood-Pressure Estimation Using Grid Search in Hyperparameter Optimization of CNN-LSTM. Diagnostics (Basel) 2023; 13:2566. [PMID: 37568929 PMCID: PMC10417316 DOI: 10.3390/diagnostics13152566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/13/2023] Open
Abstract
Researchers commonly use continuous noninvasive blood-pressure measurement (cNIBP) based on photoplethysmography (PPG) signals to monitor blood pressure conveniently. However, the performance of the system still needs to be improved. Accuracy and precision in blood-pressure measurements are critical factors in diagnosing and managing patients' health conditions. Therefore, we propose a convolutional long short-term memory neural network (CNN-LSTM) with grid search ability, which provides a robust blood-pressure estimation system by extracting meaningful information from PPG signals and reducing the complexity of hyperparameter optimization in the proposed model. The multiparameter intelligent monitoring for intensive care III (MIMIC III) dataset obtained PPG and arterial-blood-pressure (ABP) signals. We obtained 75,226 signal segments, with 60,180 signals allocated for training data, 12,030 signals allocated for the validation set, and 15,045 signals allocated for the test data. During training, we applied five-fold cross-validation with a grid-search method to select the best model and determine the optimal hyperparameter settings. The optimized configuration of the CNN-LSTM layers consisted of five convolutional layers, one long short-term memory (LSTM) layer, and two fully connected layers for blood-pressure estimation. This study successfully achieved good accuracy in assessing both systolic blood pressure (SBP) and diastolic blood pressure (DBP) by calculating the standard deviation (SD) and the mean absolute error (MAE), resulting in values of 7.89 ± 3.79 and 5.34 ± 2.89 mmHg, respectively. The optimal configuration of the CNN-LSTM provided satisfactory performance according to the standards set by the British Hypertension Society (BHS), the Association for the Advancement of Medical Instrumentation (AAMI), and the Institute of Electrical and Electronics Engineers (IEEE) for blood-pressure monitoring devices.
Collapse
Affiliation(s)
- Nurul Qashri Mahardika T
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
| | - Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Da Un Jeong
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea
- Meta Heart Co., Ltd., Gumi 39177, Gyeongbuk, Republic of Korea
| |
Collapse
|
6
|
Samimi H, Dajani HR. A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics. Sensors (Basel) 2023; 23:4145. [PMID: 37112490 PMCID: PMC10146008 DOI: 10.3390/s23084145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 06/19/2023]
Abstract
Traditional cuff-based sphygmomanometers for measuring blood pressure can be uncomfortable and particularly unsuitable to use during sleep. A proposed alternative method uses dynamic changes in the pulse waveform over short intervals and replaces calibration with information from photoplethysmogram (PPG) morphology to provide a calibration-free approach using a single sensor. Results from 30 patients show a high correlation of 73.64% for systolic blood pressure (SBP) and 77.72% for diastolic blood pressure (DBP) between blood pressure estimated with the PPG morphology features and the calibration method. This suggests that the PPG morphology features could replace the calibration stage for a calibration-free method with similar accuracy. Applying the proposed methodology on 200 patients and testing on 25 new patients resulted in a mean error (ME) of -0.31 mmHg, a standard deviation of error (SDE) of 4.89 mmHg, a mean absolute error (MAE) of 3.32 mmHg for DBP and an ME of -4.02 mmHg, an SDE of 10.40 mmHg, and an MAE of 7.41 mmHg for SBP. These results support the potential for using a PPG signal for calibration-free cuffless blood pressure estimation and improving accuracy by adding information from cardiovascular dynamics to different methods in the cuffless blood pressure monitoring field.
Collapse
|
7
|
Nour M, Polat K, Şentürk Ü, Arıcan M. A Novel Cuffless Blood Pressure Prediction: Uncovering New Features and New Hybrid ML Models. Diagnostics (Basel) 2023; 13:diagnostics13071278. [PMID: 37046499 PMCID: PMC10093721 DOI: 10.3390/diagnostics13071278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/15/2023] [Accepted: 03/23/2023] [Indexed: 03/31/2023] Open
Abstract
This paper investigates new feature extraction and regression methods for predicting cuffless blood pressure from PPG signals. Cuffless blood pressure is a technology that measures blood pressure without needing a cuff. This technology can be used in various medical applications, including home health monitoring, clinical uses, and portable devices. The new feature extraction method involves extracting meaningful features (time and chaotic features) from the PPG signals in the prediction of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. These extracted features are then used as inputs to regression models, which are used to predict cuffless blood pressure. The regression model performances were evaluated using root mean squared error (RMSE), R2, mean square error (MSE), and the mean absolute error (MAE). The obtained RMSE was 4.277 for systolic blood pressure (SBP) values using the Matérn 5/2 Gaussian process regression model. The obtained RMSE was 2.303 for diastolic blood pressure (DBP) values using the rational quadratic Gaussian process regression model. The results of this study have shown that the proposed feature extraction and regression models can predict cuffless blood pressure with reasonable accuracy. This study provides a novel approach for predicting cuffless blood pressure and can be used to develop more accurate models in the future.
Collapse
Affiliation(s)
- Majid Nour
- Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Kemal Polat
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
- Correspondence:
| | - Ümit Şentürk
- Department of Computer Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
| | - Murat Arıcan
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
| |
Collapse
|
8
|
González S, Hsieh WT, Chen TPC. A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogram. Sci Data 2023; 10:149. [PMID: 36944668 PMCID: PMC10030661 DOI: 10.1038/s41597-023-02020-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 02/14/2023] [Indexed: 03/23/2023] Open
Abstract
Blood Pressure (BP) is an important cardiovascular health indicator. BP is usually monitored non-invasively with a cuff-based device, which can be bulky and inconvenient. Thus, continuous and portable BP monitoring devices, such as those based on a photoplethysmography (PPG) waveform, are desirable. In particular, Machine Learning (ML) based BP estimation approaches have gained considerable attention as they have the potential to estimate intermittent or continuous BP with only a single PPG measurement. Over the last few years, many ML-based BP estimation approaches have been proposed with no agreement on their modeling methodology. To ease the model comparison, we designed a benchmark with four open datasets with shared preprocessing, the right validation strategy avoiding information shift and leak, and standard evaluation metrics. We also adapted Mean Absolute Scaled Error (MASE) to improve the interpretability of model evaluation, especially across different BP datasets. The proposed benchmark comes with open datasets and codes. We showcase its effectiveness by comparing 11 ML-based approaches of three different categories.
Collapse
|
9
|
Ibtehaz N, Mahmud S, Chowdhury MEH, Khandakar A, Salman Khan M, Ayari MA, Tahir AM, Rahman MS. PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms. Bioengineering (Basel) 2022; 9:692. [PMID: 36421093 PMCID: PMC9687508 DOI: 10.3390/bioengineering9110692] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/08/2022] [Accepted: 11/11/2022] [Indexed: 08/13/2023] Open
Abstract
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.
Collapse
Affiliation(s)
- Nabil Ibtehaz
- Department of Computer Science, Purdue University, West Lafayette, IN 47907, USA
| | - Sakib Mahmud
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | | | - Amith Khandakar
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | | | - Mohamed Arselene Ayari
- Department of Civil and Architectural Engineering, Qatar University, Doha 2713, Qatar
- Technology Innovation and Engineering Education Unit (TIEE), Qatar University, Doha 2713, Qatar
| | - Anas M. Tahir
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
| | - M. Sohel Rahman
- Department of CSE, BUET, ECE Building, West Palashi, Dhaka 1205, Bangladesh
| |
Collapse
|