1
|
Oliveira GR, Machry RV, Cadore-Rodrigues AC, Sarkis-Onofre R, Valandro LF, Bacchi A, Pereira G, Spazzin AO. Fatigue Properties of Weakened and Non-weakened Roots Restored with CAD-CAM Milled Fiber Post, Prefabricated Fiber Post, or Cast Metal Post. Oper Dent 2022; 47:658-669. [PMID: 36251571 DOI: 10.2341/21-032-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/27/2021] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Customized glass fiber posts using CAD-CAM technology have been suggested for restoring endodontically treated teeth. However, how weakened or non-weakened roots restored with anatomical CAD-CAM posts behave under cyclic fatigue is not clear. OBJECTIVE To evaluate the load-bearing capacity under fatigue (fatigue failure load [FFL], the number of cycles for failure [CFF], and survival probabilities) and fracture pattern of weakened and non-weakened roots restored with CAD-CAM fiber post and cores, metal cast-post-core, and prefabricated fiber post and resin core. METHODS AND MATERIALS A total of 60 crack-free bovine incisor roots (13 mm in length) with standard geometry were obtained and randomly allocated considering the factor "root condition" in two levels (weakened and non-weakened). Thus, half of the roots were weakened to obtain a wall thickness of 0.5 mm. After that, the endodontic treatment was executed, all roots embedded with acrylic resin and the specimens randomly allocated (n=10) considering the factor "post system" in three levels (CAD-CAM: CAD-CAM milled glass-fiber post and core; MBC: metallic-based post and core; and FRC: prefabricated glass-fiber post and composite resin core). The posts were luted with a dual-cure self-adhesive luting agent. Then, all teeth received a metallic crown. An initial load of 100 N at 20 Hz for 5000 cycles was applied for the step-stress fatigue test, followed by incremental steps of 50 N for 20,000 cycles each step, up to failure. A fracture pattern analysis was performed. RESULTS CAD-CAM fiber post (FFL: 865 N; CFF: 311,000 cycles) presented similar fatigue performance (p>0.05) to FRC (FFL: 925 N; CFF: 335,000 cycles), with 100% of repairable fractures for non-weakened roots; however, both groups presented worse performance than MBC (p<0.05; FFL: 1265 N; CFF: 471,000 cycles) which led to 100% of catastrophic failures. No statistical difference was found in fatigue performance among the three systems for weakened roots (p>0.05; FFL: 1035-1170 N; CFF: 379,000-433,000 cycles), with a high rate of catastrophic failures. CONCLUSIONS CAD-CAM fiber post presented similar fatigue performance to MBC and FRC approaches when restoring weakened roots. CAD-CAM was similar to FRC when restoring non-weakened roots, while MBC enhanced fatigue properties in this scenario.
Collapse
Affiliation(s)
- G R Oliveira
- Gabriel Rodrigues Oliveira, DDS, Graduate Program in Dentistry, Atitus Education, Passo Fundo, Rio Grande do Sul, Brazil
| | - R V Machry
- Renan Vaz Machry, PhD, Post-Graduate Program in Oral Science, Prosthodontics Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| | - A C Cadore-Rodrigues
- Ana Carolina Cadore-Rodrigues, PhD, Post-Graduate Program in Oral Science, Prosthodontics Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| | - R Sarkis-Onofre
- Rafael Sarkis-Onofre, PhD, Graduate Program in Dentistry, Atitus Education, Passo Fundo, Rio Grande do Sul, Brazil
| | - L F Valandro
- Luiz Felipe Valandro, PhD, Post-Graduate Program in Oral Science, Prosthodontics Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| | - A Bacchi
- Ataís Bacchi, PhD, Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Gkr Pereira
- *Gabriel Kalil Rocha Pereira, PhD, Post-Graduate Program in Oral Science, Prosthodontics Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| | - A O Spazzin
- Aloísio Oro Spazzin, PhD, Graduate Program in Dentistry, Atitus Education, Passo Fundo, Rio Grande do Sul, Brazil
| |
Collapse
|
2
|
Machry RV, Dapieve KS, Cadore-Rodrigues AC, Werner A, de Jager N, Pereira GKR, Valandro LF, Kleverlaan CJ. Mechanical characterization of a multi-layered zirconia: Flexural strength, hardness, and fracture toughness of the different layers. J Mech Behav Biomed Mater 2022; 135:105455. [PMID: 36148725 DOI: 10.1016/j.jmbbm.2022.105455] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/30/2022] [Accepted: 09/06/2022] [Indexed: 10/31/2022]
Abstract
This study compared the flexural strength under monotonic (static - sσ) and cyclic load application (fatigue - fσ), hardness (H) and fracture toughness (KIC) of different layers of a multi-layered zirconia (IPS e.max ZirCAD MT Multi, Ivoclar). Each layer was sectioned, classified into three groups according to yttria content (4-YSZ, 4/5-YSZ and 5-YSZ), and shaped on samples for flexural strength and fracture toughness tests (bars: 1.0 × 1.0 × 11 mm); and Vickers hardness test (plates: 1.5 × 4.0 × 5.0 mm). Flexural strength under monotonic load application (sσ; n = 10) was obtained through two different devices (three-point-bending and ball-in-hole device) and fatigue flexural strength (fσ; n = 15; initial load: 10 N; step-size: 5 N; 10,000 cycles/step) was assessed using a ball-in-hole device under cyclic load application. Vickers hardness test (n = 5), fracture toughness test (n = 10), and additional analyzes (Finite Element Analysis - FEA, Energy-dispersive X-ray spectroscopy - EDS and Scanning Electron Microscopy - SEM) were also performed. No differences were found between the different devices in the monotonic flexural strength test, and FEA showed similar tensile stress distribution for the two devices. 4-YSZ showed higher values of flexural strength under monotonic and cyclic load application modes (sσ = 1114.73 MPa; fσ = 798.84 MPa), and fracture toughness (KIC = 3.90 MPa√m). 4/5-YSZ had an intermediate sσ; however, fσ was similar to 5-YSZ (404.00-429.36 MPa) and KIC similar to 4-YSZ (KIC = 3.66 MPa√m). No statistical differences were found for hardness and Weibull modulus for fatigue flexural strength data. The amount of yttria in the layer compositions increased from 4-YSZ to 5-YSZ, and larger zirconia crystals were observed in the topographic images of 5-YSZ. Failures in the flexural strength and toughness tests started from the face subjected to tensile stress. Different layers of the multi-layered zirconia blank presented distinct mechanical properties. 4-YSZ (cervical layer) presented the highest flexural strength under monotonic and cyclic loads (fatigue), and higher fracture toughness even similar to the transition layer (4/5-YSZ). Hardness was similar between the layers. The ball-in-hole device performed similarly to the three-point bending device and can be used as an alternative to the traditional method.
Collapse
Affiliation(s)
- Renan Vaz Machry
- MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, 1000 Roraima Av., Santa Maria, Rio Grande do Sul, Brazil.
| | - Kiara Serafini Dapieve
- MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, 1000 Roraima Av., Santa Maria, Rio Grande do Sul, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, 1000 Roraima Av., Santa Maria, Rio Grande do Sul, Brazil.
| | - Arie Werner
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, Noord-Holland, Netherlands.
| | - Niek de Jager
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, Noord-Holland, Netherlands.
| | - Gabriel Kalil Rocha Pereira
- MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, 1000 Roraima Av., Santa Maria, Rio Grande do Sul, Brazil.
| | - Luiz Felipe Valandro
- MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, 1000 Roraima Av., Santa Maria, Rio Grande do Sul, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, Noord-Holland, Netherlands.
| |
Collapse
|
3
|
Soares PM, Cadore-Rodrigues AC, Packaeser MG, Bacchi A, Valandro LF, Pereira GKR, Rippe MP. Masking ability of implant abutment substrates by using different ceramic restorative systems. J Prosthet Dent 2022; 128:496.e1-496.e8. [PMID: 35985853 DOI: 10.1016/j.prosdent.2022.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 10/15/2022]
Abstract
STATEMENT OF PROBLEM Information regarding the masking ability of ceramic crowns over different implant abutment materials is scarce. PURPOSE The purpose of this in vitro study was to evaluate the masking ability of different monolithic or bilayer ceramic materials with different thicknesses over substrates indicated for implant restorations by using opaque and translucent evaluation pastes. MATERIAL AND METHODS Disk-shaped specimens, shade A1 (VITA Classic; Ø10×1.5 to 2.5 mm), of different ceramics (a bilayer system [yttria-stabilized zirconia infrastructure+porcelain veneer: Zir+Pc] and monolithic systems [lithium disilicate under low, medium, or high translucency: LtLD, MtLD, or HtLD, respectively, and a high-translucent yttria-stabilized zirconia: HtZir]) were made (n=4). The color difference (ΔE00) was assessed by using the CIEDE2000 formula and considering the different ceramic systems over 5 implant abutment materials (A1 shade Zir [Zir A1]; white Zir [White Zir]; A1 low-translucency lithium disilicate [LD]; polyetheretherketone [PEEK]; and titanium [Ti]) when using 2 different evaluation pastes (translucent or opaque). The control comparison was the restorative material positioned over the Zir A1 substrate with a translucent evaluation paste. Statistical analysis was made by using a 2-way ANOVA and Tukey post hoc tests (α=.05) for ΔE00 data considering the restorative material and luting agent factors as their association. Additionally, ΔE00 data were qualitatively analyzed considering the acceptability and perceptibility thresholds. The translucency parameter (TP00) of each restorative material was evaluated, and data were submitted to 1-way ANOVA and Tukey post hoc tests (α=.05). RESULTS The most predictable masking ability was seen with Zir+Pc regardless of the evaluation paste used. Nevertheless, under 1.5-mm thickness, Zir+Pc did not adequately mask Ti (ΔE00>1.77). Most monolithic ceramics did not mask discolored substrates (PEEK or Ti, ΔE00>1.77). The exception was HtZir, which presented acceptable masking ability over PEEK at 2.5-mm thickness with both evaluation pastes (ΔE00<1.77). Regardless of the restorative material thickness, Zir+Pc showed the lowest (P<.05) TP00 values (TP00=3.45 at 1.5-mm thickness; TP00=2.00 at 2.5-mm thickness), and HtLD presented the highest (P<.05, TP00=23.50 at 1.5-mm thickness; TP00=13.36 at 2.5-mm thickness). HtZir showed similar TP00 to MtLD at 1.5-mm thickness and similar TP00 to Zir+Pc when used at 2.5-mm thickness (P>.05). CONCLUSIONS Monolithic ceramics should be used with caution over discolored implant abutments. Bilayer systems (Zir+Pc) were the most predictable approach to adequately masking discolored substrates such as PEEK or Ti. An increased restoration thickness provided higher masking ability for all restorative materials tested.
Collapse
Affiliation(s)
- Pablo Machado Soares
- PhD student, Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Ana Carolina Cadore-Rodrigues
- PhD student, Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Maria Gabriela Packaeser
- Graduate student, Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Atais Bacchi
- Professor, MSciD Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Luiz Felipe Valandro
- Professor, Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- Associate Professor, Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| |
Collapse
|
4
|
Cadore-Rodrigues AC, Machry RV, Zucuni CP, Pereira GKR, Valandro LF. Grinding and polishing of the inner surface of monolithic simplified restorations made of zirconia polycrystals and lithium disilicate glass-ceramic: Effects on the load-bearing capacity under fatigue of the bonded restorations. J Mech Behav Biomed Mater 2021; 124:104833. [PMID: 34562764 DOI: 10.1016/j.jmbbm.2021.104833] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/01/2021] [Accepted: 09/07/2021] [Indexed: 10/20/2022]
Abstract
This study evaluated the effect of grinding and polishing the inner surface of monolithic discs made of zirconia polycrystals (ZR) and lithium disilicate glass-ceramic (LD) on the load-bearing capacity under fatigue of the restorations bonded onto a dentin analogue material (epoxy resin). ZR and LD ceramic discs (10 mm in diameter, 1 mm in thickness) were produced and randomly allocated into 10 groups considering the internal adjustment approach: Ctrl - No adjustment; F - Grinding with fine diamond bur (46 μm); F + Pol - Grinding with fine diamond bur followed by polishing with 2 tips (finisher and polisher); FF - Grinding with extrafine diamond bur (30 μm); FF + Pol - Grinding with extrafine diamond bur followed by polishing. In addition, discs (10 mm in diameter, 2.5 mm in thickness) of fiber reinforced epoxy resin were produced. Afterwards, the intaglio surface of the ZR discs were air-abraded with 45 μm alumina particles for 10 s, the LD and resin epoxy discs were etched with hydrofluoric acid (5%/20 s and 10%/60 s, respectively), and the treated discs were primed as recommended. Each ceramic disc was luted onto the epoxy resin disc with resin cement. Then, the samples were tested under a step-stress fatigue test (20 Hz, 10,000 cycles/step, step-size of 100 N starting at 200 N, and proceeding until failure detection). Fractographic, topographic and surface roughness analysis were also performed. The adjustments (grinding with or without polishing) (ZR: 733-880 N; LD: 1040-1106 N) triggered a detrimental effect on the fatigue behavior in both ceramics compared with the absence of treatment (control group; ZR: 973 N; LD: 1406 N). The polishing step had no effect on fatigue findings. Thus, grinding the inner surface of the tested ceramics should be avoided wherever possible to prevent introducing damage and its detrimental effects on the fatigue behavior.
Collapse
Affiliation(s)
- Ana Carolina Cadore-Rodrigues
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renan Vaz Machry
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Camila Pauleski Zucuni
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
5
|
Machry RV, Cadore-Rodrigues AC, Packaeser MG, Lorenzett E, Burgo TADL, Pereira GKR, Valandro LF. Influence of surface treatment of resin composite substrate on the load-bearing capacity under fatigue of lithium disilicate monolithic simplified restorations. J Mech Behav Biomed Mater 2021; 124:104792. [PMID: 34488172 DOI: 10.1016/j.jmbbm.2021.104792] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/20/2021] [Accepted: 08/22/2021] [Indexed: 10/20/2022]
Abstract
This study evaluated the influence of surface treatments of resin composite substrate on the fatigue behavior of adhesively cemented lithium disilicate glass-ceramic simplified restorations. CAD/CAM lithium disilicate ceramic blocks were shaped into discs (N = 60, Ø = 10 mm; thickness = 1.0 mm). Resin composite discs (N = 60, Ø = 10 mm, thickness = 2 mm) were allocated into four groups considering the "surface treatment" factor: Ctrl - no surface treatment; Bur - grinding with coarse diamond bur (#3101G, KG Sorensen); PA - etching with 37% phosphoric acid (15 s); AA - air abrasion with alumina particles (45 μm, 10 mm distance, 2.8 bars, 10 s). The surface topography, the roughness, the fractal dimension (estimated by the box-counting method) and the contact angle analyses were performed after the surface treatments. The lithium disilicate discs were etched (5% hydrofluoric acid, 20 s), silanized and adhesively cemented (Multilink N, Ivoclar Vivadent) on the resin composite discs. The samples (bonded restoration set) were subjected to a step-stress fatigue test at 20 Hz, 10,000 cycles/step with a step-size of 100 N applied on the ceramic surface, having ceramic up and resin composite down. Fractographic analysis was performed. The fatigue data (Fatigue Failure Load - FFL; and Cycles for Failure - CFF) were analyzed by Kaplan Meier with Mantel-Cox log-rank post-hoc tests (α = 0.05). No statistical difference for fatigue performance could be found among the groups (FFL means: 820-867 N; CFF means: 53,195-61,090 cycles). The bur group showed higher surface roughness and contact angle values. The PA group has the highest average fractal dimension. Therefore, the resin composite surface treatment induces topographical changes, however, it has no effect on the fatigue behavior of lithium disilicate restorations.
Collapse
Affiliation(s)
- Renan Vaz Machry
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ezequiel Lorenzett
- Post-Graduate Program in Physics, Physics Department, Federal University of Santa Maria, Brazil.
| | | | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| |
Collapse
|
6
|
Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP. Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 2021; 123:104760. [PMID: 34418777 DOI: 10.1016/j.jmbbm.2021.104760] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/03/2021] [Indexed: 11/17/2022]
Abstract
The fatigue behavior and FEA analysis of different ceramic materials cemented over distinct substrates for implant-supported crowns were evaluated in this study. Discs of 10 mm in diameter of both restorative and substrate materials were made and randomly allocated into pairs (n = 15) considering the two study factors: 'restorative ceramic material' (1 mm thickness) - polymer-infiltrated ceramic network (PICN), lithium disilicate (LD), zirconia-reinforced lithium silicate (ZLS), or translucent zirconia (TZ); and 'foundation substrate' (2 mm thickness) - polyetheretherketone (Peek) or yttrium-stabilized zirconia (YZ). Adhesive cementation was made with a dual cure resin cement. Fatigue testing was run using the step-stress methodology: initial load of 200 N for 5000 cycles, followed by steps of 10,000 cycles starting at 400 N up to 2800 N or until failure, step size of 200 N, frequency of 20 Hz. Data were analyzed by the Kaplan Meier and log-rank post-hoc tests. Fractography analysis (stereomicroscope and SEM) and FEA were also performed. Both factors under study and their interaction statistically influenced the fatigue failure load (FFL), cycles for failure (CFF) and survival rates (p < 0.001). The restorative materials bonded to YZ had higher FFL and CFF than when adhering to Peek, while restorative materials with more crystalline content (TZ and ZLS) showed higher FFL and CFF than LD and PICN. The fractography analysis showed that all materials bonded to YZ resulted in failures starting at the occlusal surface (Hertzian cone cracks), while materials bonded to Peek had radial cracks from the ceramic-cement intaglio surface. FEA analysis showed that tensile stress concentration decreased in the intaglio surface when testing the restorative material over a stiffer (YZ) foundation substrate. In addition, the higher the restorative material's crystalline content, the more the stress is concentrated within the material (TZ > ZLS ≥ LD > PICN) when bonded to the same foundation substrate. Thus, it concluded that a stiffer foundation substrate (YZ) enhances the load-bearing capacity under fatigue of the restorative set; that restorative materials with higher crystalline content results in higher fatigue performance of the set, regardless of the foundation used; and that the foundation material influences the failure pattern of the restorative set.
Collapse
Affiliation(s)
- Pablo Machado Soares
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
7
|
Cadore-Rodrigues AC, Machado PS, Oliveira JSD, Jahn SL, Dorneles LS, Rippe MP, Pereira GKR, Valandro LF. Surface treatments and its effects on the fatigue behavior of a 5% mol yttria partially stabilized zirconia material. J Mech Behav Biomed Mater 2021; 120:104543. [PMID: 33957570 DOI: 10.1016/j.jmbbm.2021.104543] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 04/14/2021] [Accepted: 04/16/2021] [Indexed: 10/21/2022]
Abstract
This study evaluated the effect of distinct surface treatments on the fatigue behavior (biaxial flexural fatigue testing) and surface characteristics (topography and roughness) of a 5% mol yttria partially stabilized zirconia ceramic (5Y-PSZ). Disc-shaped specimens of 5Y-PSZ (IPS e.max ZirCAD MT Multi) were manufactured (ISO 6872-2015) and allocated into six groups (n = 15) considering the following surface treatments: Ctrl - no-treatment; GLZ - low-fusing porcelain glaze application; SNF - 5 nm SiO2 nanofilm; AlOx - aluminum oxide particle air-abrasion; SiC - silica-coated aluminum oxide particles (silica-coating); and 7%Si - 7% silica-coated aluminum oxide particles (silica-coating). The biaxial flexural fatigue tests were performed by the step-stress method (20Hz for 10,000 cycles) with a step increment of 50N starting at 100N and proceeding until failure detection. The samples were tested with the treated surface facing down (tensile stress side). Topography, fractography, roughness, and phase content assessments of treated specimens were performed. GLZ group presented the highest fatigue behavior, while AlOx presented the lowest performance, and was only similar to SiC and 7%Si. Ctrl and SNF presented intermediary fatigue behavior, and were also similar to SiC and 7%Si. GLZ promoted a rougher surface, Ctrl and SNF had the lowest roughness, while the air-abrasion groups presented intermediary roughness. No m-phase content was detected (only t and c phases were detected). In conclusion, the application of a thin-layer of low-fusing porcelain glaze, the deposition of silica nanofilms and the air-abrasion with silica-coated alumina particles had no detrimental effect on the fatigue behavior of the 5Y-PSZ, while the air-abrasion with alumina particles damaged the fatigue outcomes.
Collapse
Affiliation(s)
- Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Pablo Soares Machado
- Post-Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Jivago Schumacher de Oliveira
- Post-Graduate Program in Chemical Engineering, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Sérgio Luiz Jahn
- Post-Graduate Program in Chemical Engineering, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucio Strazzabosco Dorneles
- Post-Graduate Program in Physics, Physics Department, Federal University of Santa Maria, Santa Maria, Brazil.
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
8
|
Machry RV, Cadore-Rodrigues AC, Borges ALS, Pereira GK, Kleverlaan CJ, Venturini AB, Valandro LF. Fatigue resistance of simplified CAD–CAM restorations: Foundation material and ceramic thickness effects on the fatigue behavior of partially- and fully-stabilized zirconia. Dent Mater 2021; 37:568-577. [DOI: 10.1016/j.dental.2021.01.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/15/2020] [Accepted: 01/09/2021] [Indexed: 10/22/2022]
|
9
|
Cadore-Rodrigues AC, Machado PS, Oliveira JSD, Jahn SL, Callegari GL, Dorneles LS, Burgo TADL, Rippe MP, Rocha Pereira GK, Valandro LF. Fatigue performance of fully-stabilized zirconia polycrystals monolithic restorations: The effects of surface treatments at the bonding surface. J Mech Behav Biomed Mater 2020; 110:103962. [PMID: 32957253 DOI: 10.1016/j.jmbbm.2020.103962] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 10/23/2022]
Abstract
This study evaluated the distinct conditioning effect of the intaglio surface of bonded fully-stabilized zirconia (FSZ) simplified restorations on the mechanical fatigue behavior of the set prior to and after aging. Ceramic disc shaped specimens (Ø= 10 mm and 1 mm thick) were randomly allocated into 14 groups considering: "surface treatments" (Ctrl: no-treatment; PM: universal primer; GLZ: low-fusing porcelain glaze; SNF: 5 nm SiO2 nanofilm deposition; AlOx: air-abrasion with aluminum oxide; SiC: air-abrasion with silica-coated aluminum oxide; 7%Si: air-abrasion with 7% silica-coated aluminum oxide); and "aging" (baseline: 24 h at 37 °C in water; or aged: 90 days at 37 °C in water + 12,000 thermal cycles). The discs were treated, luted with resin cement onto the dentin analog, subjected to aging or not, and then tested under a step-stress fatigue test at 20 Hz, 10,000 cycles/step, step-size of 100N starting at 200N, and proceeding until failure detection. Fractographic, topographic, surface roughness, contact angle, and atomic force microscopy analyzes were performed. The surface treatments at baseline led to statistically similar fatigue failure loads (953N-1313N), except for GLZ (1313N), which was significantly higher than 7%Si (953 N). Meanwhile, Ctrl had 40% pre-test failures (debonding) after aging, and therefore the worst fatigue performance (notable decrease in fatigue results), while all the other groups presented superior and statistically similar fatigue behavior (973-1271N). In fact, when considering baseline Vs aging conditions, stable fatigue results could only be noted when using surface treatments. In conclusion, internal surface treatments of FSZ ceramic restorations are mandatory for fatigue behavior stability after aging the restorative set, while non-treatment induced unstable results.
Collapse
Affiliation(s)
| | - Pablo Soares Machado
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Sérgio Luiz Jahn
- Chemical Engineering, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | | | | | - Marilia Pivetta Rippe
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Luiz Felipe Valandro
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
10
|
Alves DM, Cadore-Rodrigues AC, Prochnow C, Burgo TADL, Spazzin AO, Bacchi A, Valandro LF, Rocha Pereira GK. Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns. J Prosthet Dent 2020; 126:119-127. [PMID: 32636073 DOI: 10.1016/j.prosdent.2020.03.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 03/23/2020] [Accepted: 03/23/2020] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.
Collapse
Affiliation(s)
- Daniela Meira Alves
- Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ana Carolina Cadore-Rodrigues
- PhD student, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Catina Prochnow
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Thiago Augusto de Lima Burgo
- Adjunct Professor, Department of Physics, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Aloísio Oro Spazzin
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ataís Bacchi
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
11
|
Cadore-Rodrigues AC, Prochnow C, Burgo TAL, Oliveira JS, Jahn SL, Foletto EL, Rippe MP, Pereira GKR, Valandro LF. Stable Resin Bonding to Y-TZP Ceramic with Air Abrasion by Alumina Particles Containing 7% Silica. J Adhes Dent 2020; 22:149-159. [PMID: 32322836 DOI: 10.3290/j.jad.a44151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
PURPOSE To evaluate the influence of new air-abrasion powders with different silica concentrations (silica-coated aluminum oxide) and aging on the bond strength between composite cement and Y-TZP ceramic. MATERIALS AND METHODS Ceramic slices (7 x 6.3 x 2 mm3) were randomly allocated into 8 groups (n = 20) considering different surface treatments (SiC: silica-coated aluminum oxide particles; AlOx: aluminum oxide particles; 7% Si and 20% Si: experimental powders consisting of 7% and 20% silica-coated of AlOx respectively) and aging (baseline: 24 h at 37°C in water; aged: 90 days at 37°C in water + 12,000 thermal cycles). A blinded researcher performed the air-abrasion procedure for 10 s (identical parameters for all groups). Composite resin cylinders (Ø = 3 mm) were cemented onto the silanized ceramic surfaces, light cured, and subjected to shear bond-strength testing (wire loop Ø = 0.5 mm). The topography of the powders and air-abraded surfaces was analyzed using SEM and atomic force microscopy (AFM). The elemental composition of the powders and air-abraded surfaces was analyzed with energy dispersive spectroscopy (EDS), and surface wetting of the air-abraded surfaces was also determined by contact-angle measurements. RESULTS Under baseline conditions, all groups presented similar bond strengths, but only SiC and 7% Si yielded unaltered bond strength after aging. SiC and 7% Si presented lower contact angles. All groups presented similar surface topographies. The silica content was also similar among groups, except for AlOx. CONCLUSION 7% Si and SiC presented similar bond strength and better bonding performance after aging than AlOx and 20% Si. A higher silica concentration was not able to promote stable adhesion of composite cement after aging.
Collapse
|
12
|
Cadore-Rodrigues AC, Prochnow C, Rippe MP, Oliveira JSD, Jahn SL, Foletto EL, Pereira GKR, Valandro LF. Air-abrasion using new silica-alumina powders containing different silica concentrations: Effect on the microstructural characteristics and fatigue behavior of a Y-TZP ceramic. J Mech Behav Biomed Mater 2019; 98:11-19. [DOI: 10.1016/j.jmbbm.2019.05.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 05/20/2019] [Accepted: 05/21/2019] [Indexed: 12/20/2022]
|