Van der Heiden K, Barrett HE, Meester EJ, van Gaalen K, Krenning BJ, Beekman FJ, de Blois E, de Swart J, Verhagen HJM, van der Lugt A, Norenberg JP, de Jong M, Bernsen MR, Gijsen FJH. SPECT/CT imaging of inflammation and calcification in human carotid atherosclerosis to identify the plaque at risk of rupture. J Nucl Cardiol 2022; 29:2487-2496. [PMID: 34318395 PMCID: PMC9553768 DOI: 10.1007/s12350-021-02745-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 06/28/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Calcification and inflammation are atherosclerotic plaque compositional biomarkers that have both been linked to stroke risk. The aim of this study was to evaluate their co-existing prevalence in human carotid plaques with respect to plaque phenotype to determine the value of hybrid imaging for the detection of these biomarkers. METHODS Human carotid plaque segments, obtained from endarterectomy, were incubated in [111In]In-DOTA-butylamino-NorBIRT ([111In]In-Danbirt), targeting Leukocyte Function-associated Antigen-1 (LFA-1) on leukocytes. By performing SPECT/CT, both inflammation from DANBIRT uptake and calcification from CT imaging were assessed. Plaque phenotype was classified using histology. RESULTS On a total plaque level, comparable levels of calcification volume existed with different degrees of inflammation and vice versa. On a segment level, an inverse relationship between calcification volume and inflammation was evident in highly calcified segments, which classify as fibrocalcific, stable plaque segments. In contrast, segments with little or no calcification presented with a moderate to high degree of inflammation, often coinciding with the more dangerous fibrous cap atheroma phenotype. CONCLUSION Calcification imaging alone can only accurately identify highly calcified, stable, fibrocalcific plaques. To identify high-risk plaques, with little or no calcification, hybrid imaging of calcification and inflammation could provide diagnostic benefit.
Collapse
Affiliation(s)
- K Van der Heiden
- Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands.
| | - H E Barrett
- Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - E J Meester
- Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - K van Gaalen
- Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
| | - B J Krenning
- Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| | - F J Beekman
- MiLabs, B.V, Utrecht, The Netherlands
- Section Biomedical Imaging, Department Radiation Science & Technology, Delft University of Technology, Delft, The Netherlands
- Department of Translational Neuroscience, Brain Centre Rudolf Magnus, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - E de Blois
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - J de Swart
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - H J M Verhagen
- Department of Vascular Surgery, Erasmus MC, Rotterdam, The Netherlands
| | - A van der Lugt
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - J P Norenberg
- Radiopharmaceutical Sciences, University of New Mexico, Albuquerque, NM, USA
| | - M de Jong
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - M R Bernsen
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Applied Molecular Imaging Erasmus Core Facility, Erasmus MC Rotterdam, Rotterdam, The Netherlands
| | - F J H Gijsen
- Department of Biomedical Engineering, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Meester EJ, Krenning BJ, de Blois E, de Jong M, van der Steen AFW, Bernsen MR, van der Heiden K. Imaging inflammation in atherosclerotic plaques, targeting SST 2 with [ 111In]In-DOTA-JR11. J Nucl Cardiol 2021; 28:2506-2513. [PMID: 32026330 PMCID: PMC8709817 DOI: 10.1007/s12350-020-02046-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 12/24/2019] [Indexed: 12/26/2022]
Abstract
BACKGROUND Imaging Somatostatin Subtype Receptor 2 (SST2) expressing macrophages by [DOTA,Tyr3]-octreotate (DOTATATE) has proven successful for plaque detection. DOTA-JR11 is a SST2 targeting ligand with a five times higher tumor uptake than DOTATATE, and holds promise to improve plaque imaging. The aim of this study was to evaluate the potential of DOTA-JR11 for plaque detection. METHODS AND RESULTS Atherosclerotic ApoE-/- mice (n = 22) fed an atherogenic diet were imaged by SPECT/CT two hours post injection of [111In]In-DOTA-JR11 (~ 200 pmol, ~ 50 MBq). In vivo plaque uptake of [111In]In-DOTA-JR11 was visible in all mice, with a target-to-background-ratio (TBR) of 2.23 ± 0.35. Post-mortem scans after thymectomy and ex vivo scans of the arteries after excision of the arteries confirmed plaque uptake of the radioligand with TBRs of 2.46 ± 0.52 and 3.43 ± 1.45 respectively. Oil red O lipid-staining and ex vivo autoradiography of excised arteries showed [111In]In-DOTA-JR11 uptake at plaque locations. Histological processing showed CD68 (macrophages) and SST2 expressing cells in plaques. SPECT/CT, in vitro autoradiography and immunohistochemistry performed on slices of a human carotid endarterectomy sample showed [111In]In-DOTA-JR11 uptake at plaque locations containing CD68 and SST2 expressing cells. CONCLUSIONS The results of this study indicate DOTA-JR11 as a promising ligand for visualization of atherosclerotic plaque inflammation.
Collapse
Affiliation(s)
- Eric J Meester
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | | | - Erik de Blois
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Marion de Jong
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Antonius F W van der Steen
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
| | - Monique R Bernsen
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Kim van der Heiden
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
| |
Collapse
|
3
|
Meester EJ, de Blois E, Krenning BJ, van der Steen AFW, Norenberg JP, van Gaalen K, Bernsen MR, de Jong M, van der Heiden K. Autoradiographical assessment of inflammation-targeting radioligands for atherosclerosis imaging: potential for plaque phenotype identification. EJNMMI Res 2021; 11:27. [PMID: 33730311 PMCID: PMC7969682 DOI: 10.1186/s13550-021-00772-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 03/05/2021] [Indexed: 12/26/2022] Open
Abstract
PURPOSE Many radioligands have been developed for the visualization of atherosclerosis by targeting inflammation. However, interpretation of in vivo signals is often limited to plaque identification. We evaluated binding of some promising radioligands in an in vitro approach in atherosclerotic plaques with different phenotypes. METHODS Tissue sections of carotid endarterectomy tissue were characterized as early plaque, fibro-calcific plaque, or phenotypically vulnerable plaque. In vitro binding assays for the radioligands [111In]In-DOTATATE; [111In]In-DOTA-JR11; [67Ga]Ga-Pentixafor; [111In]In-DANBIRT; and [111In]In-EC0800 were conducted, the expression of the radioligand targets was assessed via immunohistochemistry. Radioligand binding and expression of radioligand targets was investigated and compared. RESULTS In sections characterized as vulnerable plaque, binding was highest for [111In]In-EC0800; followed by [111In]In-DANBIRT; [67Ga]Ga-Pentixafor; [111In]In-DOTA-JR11; and [111In]In-DOTATATE (0.064 ± 0.036; 0.052 ± 0.029; 0.011 ± 0.003; 0.0066 ± 0.0021; 0.00064 ± 0.00014 %Added activity/mm2, respectively). Binding of [111In]In-DANBIRT and [111In]In-EC0800 was highest across plaque phenotypes, binding of [111In]In-DOTA-JR11 and [67Ga]Ga-Pentixafor differed most between plaque phenotypes. Binding of [111In]In-DOTATATE was the lowest across plaque phenotypes. The areas positive for cells expressing the radioligand's target differed between plaque phenotypes for all targets, with lowest percentage area of expression in early plaque sections and highest in phenotypically vulnerable plaque sections. CONCLUSIONS Radioligands targeting inflammatory cell markers showed different levels of binding in atherosclerotic plaques and among plaque phenotypes. Different radioligands might be used for plaque detection and discerning early from vulnerable plaque. [111In]In-EC0800 and [111In]In-DANBIRT appear most suitable for plaque detection, while [67Ga]Ga-Pentixafor and [111In]In-DOTA-JR11 might be best suited for differentiation between plaque phenotypes.
Collapse
Affiliation(s)
- Eric J Meester
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Erik de Blois
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | | | - Antonius F W van der Steen
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
| | - Jeff P Norenberg
- Radiopharmaceutical Sciences, University of New Mexico, Albuquerque, NM, USA
| | - Kim van Gaalen
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
| | - Monique R Bernsen
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Marion de Jong
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Kim van der Heiden
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
| |
Collapse
|
4
|
Krenning BJ, der Heiden KV, Duncker DJ, de Jong M, Bernsen MR. Nuclear Imaging of Post-infarction Inflammation in Ischemic Cardiac Diseases - New Radiotracers for Potential Clinical Applications. Curr Radiopharm 2020; 14:184-208. [PMID: 33045975 DOI: 10.2174/1874471013666201012165305] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 08/03/2020] [Accepted: 08/13/2020] [Indexed: 11/22/2022]
Abstract
Acute myocardial infarction is one of the leading causes of death in the western world. Despite major improvements in myocardial reperfusion with sophisticated percutaneous coronary intervention technologies and new antithrombotic agents, there is still no effective therapy for preventing post- infarction myocardial injury and remodeling. Death of cardiomyocytes following ischemia results in "danger signals" that elicit an inflammatory reaction to remove cell debris and form scar tissue. Optimal healing of the damaged myocardial tissue requires a coordinated cellular response for sufficient wound healing and scar formation. However, if this inflammatory reaction is overactive or incompletely resolved, adverse left ventricular remodeling and heart failure may occur. Treatment aimed at the modulation of the post-MI inflammatory response has been widely pursued and investigated. Although improved infarct healing was shown in many experimental preclinical studies, to date, clinical trials using anti-inflammatory treatment strategies have been far less successful. Clearly, a need exists for predicting and selecting patients at risk and selecting the most appropriate therapy for individual patients. To this end, imaging of the post-MI response has been a topic of significant interest. In this review, we first discuss the clinical complications resulting from myocardial inflammation following AMI and the need for non-invasive imaging techniques using radiolabeled tracers. We then discuss the inflammatory reaction cascade following acute myocardial infarction, the inflammatory reaction cascade following acute myocardial infarction focusing on inflammatory cell types involved herein, and potential imaging targets for identifying these cells during the inflammatory process. In addition, we discuss specific characteristics and limitations of various preclinical animal models for ischemic heart disease since they are crucial in the development and evaluation of the imaging techniques. Finally, we discuss the need for non-invasive imaging approaches using radiolabeled tracers.
Collapse
Affiliation(s)
| | - Kim van der Heiden
- Division of Biomedical Engineering, Department of Cardiology, Thorax Center, Erasmus MC, Rotterdam, Netherlands
| | - Dirk J Duncker
- Division of Experimental Cardiology, Department of Cardiology, Thorax Center, Erasmus MC, Rotterdam, Netherlands
| | - Marion de Jong
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| | - Monique R Bernsen
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| |
Collapse
|
5
|
Meester EJ, Krenning BJ, de Swart J, Segbers M, Barrett HE, Bernsen MR, Van der Heiden K, de Jong M. Perspectives on Small Animal Radionuclide Imaging; Considerations and Advances in Atherosclerosis. Front Med (Lausanne) 2019; 6:39. [PMID: 30915335 PMCID: PMC6421263 DOI: 10.3389/fmed.2019.00039] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 02/11/2019] [Indexed: 12/20/2022] Open
Abstract
This review addresses nuclear SPECT and PET imaging in small animals in relation to the atherosclerotic disease process, one of our research topics of interest. Imaging of atherosclerosis in small animal models is challenging, as it operates at the limits of current imaging possibilities regarding sensitivity, and spatial resolution. Several topics are discussed, including technical considerations that apply to image acquisition, reconstruction, and analysis. Moreover, molecules developed for or applied in these small animal nuclear imaging studies are listed, including target-directed molecules, useful for imaging organs or tissues that have elevated expression of the target compared to other tissues, and molecules that serve as substrates for metabolic processes. Differences between animal models and human pathophysiology that should be taken into account during translation from animal to patient as well as differences in tracer behavior in animal vs. man are also described. Finally, we give a future outlook on small animal radionuclide imaging in atherosclerosis, followed by recommendations. The challenges and solutions described might be applicable to other research fields of health and disease as well.
Collapse
Affiliation(s)
- Eric J Meester
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands.,Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - B J Krenning
- Department of Cardiology, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - J de Swart
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - M Segbers
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - H E Barrett
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands.,Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - M R Bernsen
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| | - K Van der Heiden
- Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands
| | - Marion de Jong
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Netherlands
| |
Collapse
|
6
|
Affiliation(s)
- B J Krenning
- Department of Cardiology, Thorax Centre Rotterdam, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, the Netherlands
| | | |
Collapse
|
7
|
ten Kate GJR, Caliskan K, Dedic A, Meijboom WB, Neefjes LA, Manintveld OC, Krenning BJ, Ouhlous M, Nieman K, Krestin GP, de Feyter PJ. Computed tomography coronary imaging as a gatekeeper for invasive coronary angiography in patients with newly diagnosed heart failure of unknown aetiology. Eur J Heart Fail 2014; 15:1028-34. [DOI: 10.1093/eurjhf/hft090] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Gert-Jan R. ten Kate
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | - Kadir Caliskan
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
| | - Admir Dedic
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | - W. Bob Meijboom
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
| | - Lisan A. Neefjes
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | | | | | - Mohammed Ouhlous
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | - Koen Nieman
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | - Gabriel P. Krestin
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| | - Pim J. de Feyter
- Department of Cardiology; Thorax Centre Rotterdam; The Netherlands
- Department of Radiology; Erasmus Medical Centre; Rotterdam The Netherlands
| |
Collapse
|
8
|
Abstract
BACKGROUND Dobutamine stress echocardiography (DSE) is an accepted test for the diagnosis of coronary artery disease (CAD), despite its wide diagnostic accuracy. AIM Which factors cause test variability of DSE for the diagnosis of CAD. METHODS In a retrospective analysis of 46 studies in 5,353 patients, the potential causes of diagnostic variability were systematically analyzed, including patient selection, definition of CAD, chest pain characteristics, confounding factors for DSE (left ventricular hypertrophy, left bundle branch block, female gender), work-up bias (present when patient's chance to undergo coronary angiography is influenced by the result of DSE), review bias (present when DSE is interpreted in relation to CAG), DSE protocol and definition of a positive DSE. RESULTS Diagnostic variability was related to definition of a positive test, but not related to the definition of CAD or DSE protocol. However, only three of eight methodological standards for research design found general compliance. Differences in the selection of the study population (quality of echocardiographic window, angina pectoris), handling of confounding factors and analysis of disease in individual coronary arteries were observed. Lack of data on analysis of relevant chest pain syndromes and handling of nondiagnostic test results hampered further evaluation of these standards. CONCLUSION Methodological problems may explain the wide range in diagnostic variability of DSE. An improvement of clinical relevance of DSE testing is possible by stronger adherence to common and new methodological standards.
Collapse
|
9
|
Geleijnse ML, Krenning BJ, van Dalen BM, Nemes A, Soliman OII, Bosch JG, Galema TW, ten Cate FJ, Boersma E. Factors affecting sensitivity and specificity of diagnostic testing: dobutamine stress echocardiography. J Am Soc Echocardiogr 2009; 22:1199-208. [PMID: 19766453 DOI: 10.1016/j.echo.2009.07.006] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2008] [Indexed: 12/15/2022]
Abstract
BACKGROUND Clinical characteristics of patients, angiographic referral bias, and several technical factors may all affect the reported diagnostic accuracy of tests. The aim of this study was to assess their influence on the diagnostic accuracy of dobutamine stress echocardiography (DSE). METHODS The medical literature from 1991 to 2006 was searched for diagnostic studies using DSE and meta-analysis was applied to the 62 studies thus retrieved, including 6881 patients. These studies were analyzed for patient characteristics, angiographic referral bias, and several technical factors. RESULTS The sensitivity of DSE was significantly related to the inclusion of patients with prior myocardial infarctions (0.834 vs 0.740, P < .01) and defining the results of DSE as already positive in case of resting wall motion abnormalities rather than obligatory myocardial ischemia (0.786 vs 0.864, P < .01). Specificity tended to be lower when patients with resting wall motion abnormalities were included in a study (0.812 vs 0.877, P < .10). The presence of referral bias adversely affected the specificity of DSE (0.771 vs 0.842, P < .01). CONCLUSION This analysis suggests that the reported sensitivity of DSE is likely higher and the specificity lower than expected in routine clinical practice because of the inappropriate inclusion of patients with prior myocardial infarctions, the definition of positive results on DSE, and the negative influence of referral bias. However, in the patient subset that will be sent to coronary angiography, the opposite results can be expected.
Collapse
|
10
|
Nemes A, Leung KYE, van Burken G, van Stralen M, Bosch JG, Soliman OI, Krenning BJ, Vletter WB, Cate FJT, Geleijnse ML. Side-by-Side Viewing of Anatomically Aligned Left Ventricular Segments in Three-Dimensional Stress Echocardiography. Echocardiography 2009; 26:189-95. [DOI: 10.1111/j.1540-8175.2008.00796.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
11
|
Nemes A, Timmermans RGM, Wilson JHP, Soliman OII, Krenning BJ, ten Cate FJ, Geleijnse ML. The mild form of mucopolysaccharidosis type I (Scheie syndrome) is associated with increased ascending aortic stiffness. Heart Vessels 2008; 23:108-11. [PMID: 18389335 DOI: 10.1007/s00380-007-1013-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2007] [Accepted: 08/31/2007] [Indexed: 11/28/2022]
Abstract
Mucopolysaccharidosis type I (MPS IS) is a rare autosomal recessive disease caused by a deficiency of the lysosomal enzyme alpha-L-iduronidase, which is involved in the degradation of sulfated glycosaminoglycans (GAGs). The deficiency results in the intra-and pericellular accumulation of the GAGs heparan sulfate and dermatan sulfate. Eight adult patients with typical features of MPS IS aged 31.5 +/- 6.8 years (five men) were included and compared to age-and gender-matched controls. With transthoracic echocardiography, cyclic ascending aortic diameter changes were measured and ascending aortic elastic properties were calculated to characterize aortic elasticity. In MPS IS patients, aortic stiffness index was significantly increased (23.1 +/- 10.4 vs 3.9 +/- 1.5, P < 0.001), while aortic distensibility was significantly decreased (1.6 +/- 0.8 vs 4.6 [corrected] +/- 1.9 cm(2)/dynes [corrected] 10(-6), P < 0.001) compared to age-and sex-matched controls. The results of the present study demonstrate that in addition to the known cardiac complications, MPS IS patients have an impairment of ascending aortic elasticity. Further follow-up studies are needed to examine arterial elasticity using other methods in this patient population, and to detect possible effects of enzyme replacement therapy.
Collapse
Affiliation(s)
- Attila Nemes
- Department of Cardiology, Thoraxcenter, Erasmus Medical Center Rotterdam, Dr Molewaterplein 40 Room Ba304, 3015 GD, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
12
|
Soliman OII, Krenning BJ, Geleijnse ML, Nemes A, van Geuns RJ, Baks T, Anwar AM, Galema TW, Vletter WB, ten Cate FJ. A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes. Echocardiography 2008; 24:967-74. [PMID: 17894576 DOI: 10.1111/j.1540-8175.2007.00502.x] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVES To compare the interobserver variability and accuracy of two different real time three-dimensional echocardiography (RT3DE) analyzing programs. METHODS Forty-one patients (mean age 56 +/- 11 years, 28 men) in sinus rhythm with a cardiomyopathy and adequate 2D image quality underwent RT3DE and magnetic resonance imaging (MRI) within one day. Off-line left ventricular (LV) volume analysis was performed with QLAB V4.2 (semiautomated border detection with biplane projections) and TomTec 4D LV analysis V2.0 (primarily manual tracking with triplane projections and semiautomated border detection). RESULTS Excellent correlations (R(2) > 0.98) were found between MRI and RT3DE. Bland-Altman analysis revealed an underestimated LV end-diastolic volume (LV-EDV) for both TomTec (-9.4 +/- 8.7 mL) and QLAB (-16.4 +/- 13.1 ml). Also, an underestimated LV end-systolic volume (LV-ESV) for both TomTec (-4.8 +/- 9.9 mL) and QLAB (-8.5 +/- 14.2 mL) was found. LV-EDV and LV-ESV were significantly more underestimated with QLAB software. Both programs accurately calculated LV ejection fraction (LV-EF) without a bias. Interobserver variability was 6.4 +/- 7.8% vs. 12.2 +/- 10.1% for LV-EDV, 7.8 +/- 9.7% vs. 13.6 +/- 11.2% for LV-ESV, and 7.1 +/- 6.9% vs. 9.7 +/- 8.8% for LV-EF for TomTec vs. QLAB, respectively. The analysis time was shorter with QLAB (4 +/- 2 minutes vs. 6 +/- 2 minutes, P < 0.05). CONCLUSIONS RT3DE with TomTec or QLAB software analysis provides accurate LV-EF assessment in cardiomyopathic patients with distorted LV geometry and adequate 2D image quality. However, LV volumes may be somewhat more underestimated with the current QLAB software version.
Collapse
Affiliation(s)
- Osama I I Soliman
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Nemes A, Geleijnse ML, Soliman OI, Anwar AM, Bosch JG, Krenning BJ, Yap SC, Vletter WB, McGhie JS, Forster T, Csanády M, ten Cate FJ. Real-time 3-dimensional echocardiography – can there be one more dimension? Orv Hetil 2007; 148:2451-60. [DOI: 10.1556/oh.2007.28230] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
A kardiológiai betegek ellátásában a noninvazív vizsgáló módszereknek alapvető jelentőségük van. Elméletileg a szív akkor vizsgálható tökéletesen, ha természetének megfelelően három dimenzióban rögzítjük a szívciklus szerint. A második generációs, immár real-time (vagyis valós idejű) háromdimenziós echokardiográfok elméletileg optimális lehetőséget nyújtanak a cardialis struktúrák háromdimenziós elemzésére. Real-time 3-dimenziós echokardiográfia során pontosan mérhetők a kamrai és pitvari térfogatok, valamint a kamrai izomtömeg. A billentyűk és a congenitalis abnormalitások ‘en-face’ vizsgálhatók. Használhatóságát terheléses protokollok alkalmazása mellett igazolták. A jelen összefoglaló közlemény célja a módszer bemutatása, lehetséges előnyeinek tisztázása a jelenleg még fennálló technológiai korlátok bemutatásával együtt.
Collapse
Affiliation(s)
| | | | | | | | - Johan G. Bosch
- 1 Erasmus MC, Thoraxcentrum Kardiológiai Klinika Rotterdam Hollandia
| | | | - Sing-Chien Yap
- 1 Erasmus MC, Thoraxcentrum Kardiológiai Klinika Rotterdam Hollandia
| | - Wim B. Vletter
- 1 Erasmus MC, Thoraxcentrum Kardiológiai Klinika Rotterdam Hollandia
| | - Jackie S. McGhie
- 1 Erasmus MC, Thoraxcentrum Kardiológiai Klinika Rotterdam Hollandia
| | - Tamás Forster
- 2 Szegedi Tudományegyetem, Általános Orvostudományi Kar II. Belgyógyászati Klinika és Kardiológiai Központ Szeged Korányi fasor 6. 6720
| | - Miklós Csanády
- 2 Szegedi Tudományegyetem, Általános Orvostudományi Kar II. Belgyógyászati Klinika és Kardiológiai Központ Szeged Korányi fasor 6. 6720
| | | |
Collapse
|
14
|
Nemes A, Geleijnse ML, Vletter WB, Krenning BJ, Soliman OI, Cate FJT. Role of Parasternal Data Acquisition During Contrast Enhanced Real-Time Three-Dimensional Echocardiography. Echocardiography 2007; 24:1081-5. [DOI: 10.1111/j.1540-8175.2007.00524.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
15
|
Krenning BJ, Kirschbaum SW, Soliman OI, Nemes A, van Geuns RJ, Vletter WB, Veltman CE, ten Cate FJ, Roelandt JR, Geleijnse ML. Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function. Am J Cardiol 2007; 100:1485-9. [PMID: 17950813 DOI: 10.1016/j.amjcard.2007.06.042] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2007] [Revised: 05/22/2007] [Accepted: 06/03/2007] [Indexed: 11/26/2022]
Abstract
Ultrasound contrast has shown to improve endocardial border definition. The purpose of this study was to evaluate the value of contrast agent-enhanced versus non-contrast agent-enhanced real-time 3-dimensional echocardiography (RT3DE) for the assessment of left ventricular (LV) volumes and ejection fraction. Thirty-nine unselected patients underwent RT3DE with and without SonoVue contrast agent enhancement and magnetic resonance imaging (MRI) on the same day. An image quality index was calculated by grading all 16 individual LV segments on a scale of 0 to 4: 0, not visible; 1, poor; 2, moderate; 3, good; and 4, excellent. The 3-dimensional data sets were analyzed offline using dedicated TomTec analysis software. By manual tracing, LV end-systolic volume, LV end-diastolic volume, and LV ejection fraction were calculated. After contrast agent enhancement, mean image quality index improved from 2.4 +/- 1.0 to 3.0 +/- 0.9 (p <0.001). Contrast agent-enhanced RT3DE measurements showed better correlation with MRI (LV end-diastolic volume, r = 0.97 vs 0.86; LV end-systolic volume, r = 0.96 vs 0.94; LV ejection fraction, r = 0.94 vs 0.81). The limits of agreement (Bland-Altman analysis) showed a similar bias for RT3DE images with and without contrast agent but with smaller limits of agreement for contrast agent-enhanced RT3DE. Also, inter- and intraobserver variabilities decreased. In a subgroup, patients with poor to moderate image quality showed an improvement in agreement after administration of contrast agent (+/-24.4% to +/-12.7%) to the same level as patients with moderate to good image quality without contrast agent (+/-10.4%). In conclusion, contrast agent-enhanced RT3DE is more accurate in assessment of LV function as evidenced by better correlation and narrower limits of agreement compared with MRI, as well as lower intra- and interobserver variabilities.
Collapse
|
16
|
Krenning BJ, Vletter WB, Nemes A, Geleijnse ML, Roelandt JRTC. Real-time 3-Dimensional Contrast Stress Echocardiography: A Bridge Too Far? J Am Soc Echocardiogr 2007; 20:1224-5. [PMID: 17686612 DOI: 10.1016/j.echo.2007.07.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2007] [Indexed: 11/22/2022]
|
17
|
Geleijnse ML, Krenning BJ, Nemes A, Soliman OII, Galema TW, ten Cate FJ. Diagnostic value of dobutamine stress echocardiography in patients with normal wall motion at rest. Echocardiography 2007; 24:553-7. [PMID: 17456075 DOI: 10.1111/j.1540-8175.2007.00427.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
18
|
Krenning BJ, Voormolen MM, Geleijnse ML, van der Steen AFW, ten Cate FJ, Ie EHY, Roelandt JRTC. Three-dimensional echocardiographic analysis of left ventricular function during hemodialysis. Nephron Clin Pract 2007; 107:c43-9. [PMID: 17713350 DOI: 10.1159/000107553] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2006] [Accepted: 04/17/2007] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The effects of hemodialysis (HD) on left ventricular (LV) function have been studied by various echocardiographic techniques (M-mode, 2D echocardiography). These studies are hampered by a low accuracy of measurements because of geometric assumptions regarding LV shape. Three-dimensional echocardiography (3DE) overcomes this limitation. METHODS We tested the feasibility of 3DE assessment of LV function during HD. Conventional biplane Simpson rule (BSR) and single plane area length method (SPM) for LV function analysis were used as a reference. RESULTS 12 HD patients were studied and in 10 (83%) a total of 80 3D datasets were acquired. In 3 patients, one dataset (4%) was of insufficient quality and excluded from analysis. Correlation between SPM, BSR and 3DE for calculation of end-diastolic (EDV, r = 0.89 and r = 0.92, respectively), end-systolic volume (ESV, r = 0.92 and r = 0.93, respectively) and for ejection fraction (EF, r = 0.90 and r = 0.88, respectively) was moderate. Limits-of-agreement results for EDV and ESV were poor with confidence intervals larger than 30 ml. Both 2DE methods underestimated end-diastolic and end-systolic volume, while overestimating ejection fraction. CONCLUSION 3DE is feasible for image acquisition during HD, which opens the possibility for accurate and reproducible measurement of LV function during HD. This may improve the assessment of the acute effect of HD on LV performance, and guide therapeutic strategies aimed at preventing intradialytic hypotension.
Collapse
|
19
|
Anwar AM, Soliman OII, Nemes A, Germans T, Krenning BJ, Geleijnse ML, Van Rossum AC, ten Cate FJ. Assessment of Mitral Annulus Size and Function by Real-time 3-Dimensional Echocardiography in Cardiomyopathy: Comparison with Magnetic Resonance Imaging. J Am Soc Echocardiogr 2007; 20:941-8. [PMID: 17555937 DOI: 10.1016/j.echo.2007.01.026] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2006] [Indexed: 11/21/2022]
Abstract
OBJECTIVE We sought to assess mitral annular (MA) size and function in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM) using real-time 3-dimensional (3D) echocardiography (RT3DE). METHODS The study included 30 patients with HCM, 20 patients with DCM, and 30 control subjects. RT3DE measurements included end-systolic and end-diastolic MA area (MAA) (MAA(3D)), MA diameter(3D), MA fractional area change (MAFAC), and MA fractional shortening. In subgroup of 50 patients, magnetic resonance imaging (MRI) was used for MAA(MRI) and MA diameter(MRI) measurement. RESULTS End-diastolic MAA(3D) was larger in HCM than in control group (P < .0001). Higher MAFAC and MA fractional shortening were present in HCM than in control group (P = .001 and P = .006, respectively). End-systolic and end-diastolic MAA(3D) in DCM were higher than in HCM and control groups (P < .0001). Lower MAFAC and MA fractional shortening were present in DCM than in HCM and control groups (P < .0001). MAFAC correlated well with left ventricular function in control subjects (r = 0.94, P < .0001), whereas correlation was less in DCM (r = 0.53, P = .02) and HCM (r = 0.42, P < .01). RT3DE and MRI measurements were comparable. CONCLUSION RT3DE assessment of MA size and function in control subjects and patients with cardiomyopathy is accurate and well correlated with MRI.
Collapse
Affiliation(s)
- Ashraf M Anwar
- Cardiology Department, Al-Husein University Hospital, Al-Azhar University, Cairo, Egypt
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Soliman OII, Krenning BJ, Geleijnse ML, Nemes A, Bosch JG, van Geuns RJ, Kirschbaum SW, Anwar AM, Galema TW, Vletter WB, ten Cate FJ. Quantification of left ventricular volumes and function in patients with cardiomyopathies by real-time three-dimensional echocardiography: a head-to-head comparison between two different semiautomated endocardial border detection algorithms. J Am Soc Echocardiogr 2007; 20:1042-9. [PMID: 17566696 DOI: 10.1016/j.echo.2007.02.011] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVE We evaluated two different commercially available real-time 3-dimensional echocardiographic semiautomated border detection algorithms for left ventricular (LV) volume analysis in patients with cardiomyopathy and distorted LV geometry. METHODS A total of 53 patients in sinus rhythm with various types of cardiomyopathy (mean age 56 +/- 11 years, 28 men) and adequate 2-dimensional image quality were included. The real-time 3-dimensional echocardiographic multiplane interpolation (MI) and full volume reconstruction (FVR) methods were used for LV volume analysis. Magnetic resonance imaging was used as the reference method. RESULTS A strong correlation (R(2) > 0.95) was found for all LV volume and ejection fraction measurements by either real-time 3-dimensional echocardiographic method. Analysis time was shorter with the FVR method (6 +/- 2 vs 15 +/- 4 minutes, P < .01) as compared with the MI method. Bland-Altman analysis showed greater underestimation of end-diastolic and end-systolic volumes by MI compared with FVR. For the MI method a bias of -24.0 mL (-15.0% of the mean) for end-diastolic volume and -11.3 mL (-18.0% of the mean) for end-systolic volume was found. For FVR analysis these values were -9.9 mL (-6.0% of the mean) and -5.0 mL (-9.0% of the mean), respectively. Ejection fraction was similar for the MI and FVR method with a mean difference compared with magnetic resonance imaging of 0.6 (1.0%) and 0.8 (1.3%), respectively. CONCLUSION In patients with cardiomyopathy, distorted LV geometry, and good 2-dimensional image quality, the FVR method is faster and more accurate than the MI method in assessment of LV volumes.
Collapse
Affiliation(s)
- Osama I I Soliman
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Voormolen MM, Krenning BJ, van Geuns RJ, Borsboom J, Lancée CT, ten Cate FJ, Roelandt JR, van der Steen AF, de Jong N. Efficient Quantification of the Left Ventricular Volume Using 3-Dimensional Echocardiography: The Minimal Number of Equiangular Long-axis Images for Accurate Quantification of the Left Ventricular Volume. J Am Soc Echocardiogr 2007; 20:373-80. [DOI: 10.1016/j.echo.2006.09.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2006] [Indexed: 11/25/2022]
|
22
|
Geleijnse ML, Krenning BJ, Soliman OII, Nemes A, Galema TW, ten Cate FJ. Dobutamine stress echocardiography for the detection of coronary artery disease in women. Am J Cardiol 2007; 99:714-7. [PMID: 17317379 DOI: 10.1016/j.amjcard.2006.09.124] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2006] [Revised: 09/25/2006] [Accepted: 09/25/2006] [Indexed: 11/23/2022]
Abstract
Dobutamine stress echocardiography (DSE) has good diagnostic accuracy for the diagnosis of coronary artery disease (CAD). However, in most published diagnostic studies, patients are predominantly men. In women, diagnostic accuracy may be lower because of a lower prevalence and extent of CAD, a higher incidence of dobutamine stress-induced hypotension (resulting in less stress or even nondiagnostic test results), smaller left ventricular chamber size, and the beneficial effects of estrogens on the induction of myocardial ischemia. To determine the diagnostic accuracy of DSE in women, 14 diagnostic studies published through 2006 were identified through a Medline search. For a total of 901 patients, the weighted mean sensitivity and specificity were 72% and 88%, respectively. In 7 studies directly comparing results in women and men, conflicting results were reported. However, pooled data showed nearly identical values for sensitivity and specificity in women and men. Additionally, in 6 studies directly comparing DSE results in women with those of stress nuclear scintigraphy, DSE was as sensitive and more specific to detect CAD (90% vs 70%, p <0.0001). The excellent specificity of DSE in women was also confirmed by excellent normalcy rates, ranging from 92% to 100% in women, with a <5% pretest probability of CAD. In conclusion, despite some theoretical limitations, DSE has reasonable sensitivity and excellent specificity for the detection of CAD in women. Considering the diagnostic problems of exercise electrocardiography and nuclear scintigraphy in women, stress echocardiography may be the stress modality of choice in women because of its superior diagnostic specificity.
Collapse
|
23
|
Nemes A, Geleijnse ML, Krenning BJ, Soliman OII, Anwar AM, Vletter WB, Ten Cate FJ. Usefulness of ultrasound contrast agent to improve image quality during real-time three-dimensional stress echocardiography. Am J Cardiol 2007; 99:275-8. [PMID: 17223433 DOI: 10.1016/j.amjcard.2006.08.023] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2006] [Revised: 08/01/2006] [Accepted: 08/01/2006] [Indexed: 12/13/2022]
Abstract
Dobutamine stress echocardiography is an accepted tool for the diagnosis of coronary artery disease. Some investigators have claimed that 3-dimensional imaging improves the diagnostic accuracy of dobutamine stress echocardiography. The purpose of the present investigation was to examine the role of contrast echocardiography in the improvement of segmental quality and interobserver agreement during stress real-time 3-dimensional echocardiography (RT3DE). The study comprised 36 consecutive patients with stable chest pain referred for routine stress testing. Three-dimensional images were acquired with an RT3DE system with an X4 matrix-array transducer. All available reconstructed 2-dimensional segments were graded as optimal, good, moderate, or poor. Wall motion was scored as normal, mild hypokinesia, severe hypokinesia, akinesia, or dyskinesia. At peak stress, 466 of the 612 segments (76%) could be analyzed during conventional RT3DE. With contrast-enhanced RT3DE, the number of available segments increased to 553 (90%). The image quality index during conventional RT3DE was 2.2, whereas with contrast-enhanced RT3DE, it was 3.1. With conventional RT3DE, 2 independent observers agreed on the diagnosis of myocardial ischemia in 85 of 108 coronary territories (79%, kappa = 0.26). With contrast-enhanced RT3DE, agreement increased to 95 of 108 coronary territories (88%, kappa = 0.59). Study agreement on myocardial ischemia was present in 26 of 36 studies (72%, kappa = 0.43) with conventional RT3DE and in 32 of 36 studies (89%, kappa = 0.77) with contrast-enhanced RT3DE. In conclusion, during stress RT3DE, contrast-enhanced imaging significantly decreases the number of poorly visualized myocardial segments and improves interobserver agreement for the diagnosis of myocardial ischemia.
Collapse
Affiliation(s)
- Attila Nemes
- Department of Cardiology, Thoraxcentre, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
24
|
Anwar AM, Soliman OII, ten Cate FJ, Nemes A, McGhie JS, Krenning BJ, van Geuns RJ, Galema TW, Geleijnse ML. True mitral annulus diameter is underestimated by two-dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging. Int J Cardiovasc Imaging 2006; 23:541-7. [PMID: 17164985 DOI: 10.1007/s10554-006-9181-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2006] [Accepted: 10/09/2006] [Indexed: 10/23/2022]
Abstract
BACKGROUND Mitral annulus assessment is of great importance for the diagnosis and treatment of mitral valve disease. The present study sought to assess the value of real-time three-dimensional echocardiography for the assessment of true mitral annulus diameter (MAD). METHODS One hundred and fifty patients (mean age 38 +/- 18 years) with adequate two-dimensional (2D) echocardiographic image quality underwent assessment of MAD(2D) and MAD(3D) (with real-time three-dimensional echocardiography). In a subgroup of 30 patients true MAD was validated with magnetic resonance imaging (MRI). RESULTS There was a good interobserver agreement for MAD(2D) (mean difference = -0.25 +/- 2.90 mm, agreement: -3.16, 2.66) and MAD(3D) (mean difference = 0.29 +/- 2.03, agreement = -1.74, 2.32). Measurements of MAD(2D) and MAD(3D) were well correlated (R = 0.81, P < 0.0001). However, MAD(3D) was significantly larger than MAD(2D) (3.7 +/- 0.9 vs. 3.3 +/- 0.8 cm, P < 0.0001). In the subgroup of 30 patients with MRI validation, MAD(3D) and MAD(MRI) were significantly larger than MAD(2D) (3.3 +/- 0.5 and 3.4 +/- 0.5 cm vs. 2.9 +/- 0.4 cm, both P < 0.001). There was no significant difference between MAD(MRI) and MAD(3D). CONCLUSION MAD(3D) can be reliably measured and is superior to MAD(2D) in the assessment of true mitral annular size.
Collapse
Affiliation(s)
- Ashraf M Anwar
- Thoraxcenter, Room Ba 302, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Voormolen MM, Krenning BJ, Lancée CT, ten Cate FJ, Roelandt JRTC, van der Steen AFW, de Jong N. Harmonic 3-D echocardiography with a fast-rotating ultrasound transducer. IEEE Trans Ultrason Ferroelectr Freq Control 2006; 53:1739-48. [PMID: 17036783 DOI: 10.1109/tuffc.2006.107] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Although the advantages of three-dimensional (3-D) echocardiography have been acknowledged, its application for routine diagnosis is still very limited. This is mainly due to the relatively long acquisition time. Only recently has this problem been addressed with the introduction of new real-time 3-D echo systems. This paper describes the design, characteristics, and capabilities of an alternative concept for rapid 3-D echocardiographic recordings. The presented fast-rotating ultrasound (FRU)-transducer is based on a 64-element phased array that rotates with a maximum speed of 8 Hz (480 rpm). The large bandwidth of the FRU-transducer makes it highly suitable for tissue and contrast harmonic imaging. The transducer presents itself as a conventional phased-array transducer; therefore, it is easily implemented on existing 2-D echo systems, without additional interfacing. The capabilities of the FRU-transducer are illustrated with in-vitro volume measurements, harmonic imaging in combination with a contrast agent, and a preliminary clinical study.
Collapse
|
26
|
Krenning BJ, Voormolen MM, van Geuns RJ, Vletter WB, Lancée CT, de Jong N, Ten Cate FJ, van der Steen AFW, Roelandt JRTC. Rapid and Accurate Measurement of Left Ventricular Function with a New Second-Harmonic Fast-Rotating Transducer and Semi-Automated Border Detection. Echocardiography 2006; 23:447-54. [PMID: 16839381 DOI: 10.1111/j.1540-8175.2006.00241.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Measurement of left ventricular (LV) volume and function are the most common clinical referral questions to the echocardiography laboratory. A fast, practical, and accurate method would offer important advantages to obtain this important information. To validate a new practical method for rapid measurement of LV volume and function. We developed a continuous fast-rotating transducer, with second-harmonic capabilities, for three-dimensional echocardiography (3DE). Fifteen cardiac patients underwent both 3DE and magnetic resonance imaging (reference method) on the same day. 3DE image acquisition was performed during a 10-second breath-hold with a frame rate of 100 frames/sec and a rotational speed of 6 rotations/sec. The individual images were postprocessed with Matlab software using multibeat data fusion. Subsequently, with these images, 12 datasets per cardiac cycle were reconstructed, each comprising seven equidistant cross-sectional images for analysis in the new TomTec 4DLV analysis software, which uses a semi-automated border detection (ABD) algorithm. The ABD requires an average analysis time of 15 minutes per patient. A strong correlation was found between LV end-diastolic volume (r = 0.99; y = 0.95x - 1.14 ml; SEE = 6.5 ml), LV end-systolic volume (r = 0.96; y = 0.89x + 7.91 ml; SEE = 7.0 ml), and LV ejection fraction (r = 0.93; y = 0.69x + 13.36; SEE = 2.4%). Inter- and intraobserver agreement for all measurements was good. The fast-rotating transducer with new ABD software is a dedicated tool for rapid and accurate analysis of LV volume and function.
Collapse
Affiliation(s)
- Boudewijn J Krenning
- Department of Cardiology, Thoraxcenter and Department of Radiology, Erasmus Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Norenberg JP, Krenning BJ, Konings IRHM, Kusewitt DF, Nayak TK, Anderson TL, de Jong M, Garmestani K, Brechbiel MW, Kvols LK. 213Bi-[DOTA0, Tyr3]Octreotide Peptide Receptor Radionuclide Therapy of Pancreatic Tumors in a Preclinical Animal Model. Clin Cancer Res 2006; 12:897-903. [PMID: 16467104 DOI: 10.1158/1078-0432.ccr-05-1264] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE The somatostatin analogue [DOTA0, Tyr3]octreotide (DOTATOC) has previously been labeled with low linear energy transfer (LET) beta-emitters, such as 177Lu or 90Y, for tumor therapy. In this study, DOTATOC labeled with the high-LET alpha-emitter, 213Bi, was evaluated. EXPERIMENTAL DESIGN The radiolabeling, stability, biodistribution, toxicity, safety, and therapeutic efficacy of 213Bi-DOTATOC (specific activity 7.4 MBq/microg) were investigated. Biodistribution studies to determine somatostatin receptor specificity were done in Lewis rats at 1 and 3 hours postinjection. Histopathology of various organs was used to evaluated toxicity and safety. Therapeutic efficacy of 4 to 22 MBq 213Bi-DOTATOC was determined in a rat pancreatic carcinoma model. RESULTS Radiolabeling of the 213Bi-DOTATOC was achieved with radiochemical purity >95% and an incorporation yield > or = 99.9%. Biodistribution data showed specific binding to somatostatin receptor-expressing tissues. Administration of free 213Bi, compared with 213Bi-DOTATOC, resulted in higher radioactivity accumulation at 3 hours postinjection in the kidneys [34.47 +/- 1.40% injected dose/g (ID/g) tissue versus 11.15 +/- 0.46%, P < 0.0001] and bone marrow (0.31 +/- 0.01% ID/g versus 0.06 +/- 0.02%, P < 0.0324). A significant decrease in tumor growth rate was observed in rats treated with >11 MBq of 213Bi-DOTATOC 10 days postinjection compared with controls (P < 0.025). Treatment with >20 MBq of 213Bi-DOTATOC showed significantly greater tumor reduction when compared with animals receiving <11 MBq (P < 0.02). CONCLUSIONS 213Bi-DOTATOC showed dose-related antitumor effects with minimal treatment-related organ toxicity. No acute or chronic hematologic toxicities were observed. Mild, acute nephrotoxicity was observed without evidence of chronic toxicity. 213Bi-DOTATOC is a promising therapeutic radiopharmaceutical for further evaluation.
Collapse
Affiliation(s)
- Jeffrey P Norenberg
- College of Pharmacy, University of New Mexico, Albuquerque, New Mexico 87131-0001, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
van den Bosch AE, Robbers-Visser D, Krenning BJ, McGhie JS, Helbing WA, Meijboom FJ, Roos-Hesselink JW. Comparison of real-time three-dimensional echocardiography to magnetic resonance imaging for assessment of left ventricular mass. Am J Cardiol 2006; 97:113-7. [PMID: 16377294 DOI: 10.1016/j.amjcard.2005.07.114] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2005] [Revised: 07/25/2005] [Accepted: 07/25/2005] [Indexed: 11/28/2022]
Abstract
This is the first study to assess the feasibility and accuracy of real-time 3-dimensional echocardiography (RT-3DE) for the measurements of left ventricular (LV) mass in patients with congenital heart disease (CHD) compared with magnetic resonance imaging (MRI). Twenty patients (60% men) with CHD were evaluated by MRI and RT-3DE on the same day. Their mean age was 29 +/- 8 years (range 19 to 49). RT-3DE was performed with a Philips Sonos 7500 echocardiographic system and LV mass analyses with the assistance of TomTec software. The results for LV mass obtained by manual tracing were compared with Signa 1.5-T MRI data. The acquisition of RT-3DE data sets was feasible in all 20 patients. Nine patients (45%) had good, 5 patients (25%) moderate, and 6 patients (30%) poor image quality of the 3-dimensional data set. The time of 3-dimensional data acquisition was 4 +/- 2 minutes. Off-line image processing and tracing required approximately 11 +/- 3 minutes. A very good correlation was observed between RT-3DE data with sufficient image quality and MRI (r = 0.98, y = 0.96x + 4.1, SEE 9.8 g), with a mean difference of 2.0 +/- 20 g. Interobserver agreement was excellent (r = 0.99, y = 0.97x + 3.81), with a mean difference of -1 +/- 11 g. In conclusion, the assessment of LV mass from RT-3DE data is feasible in patients with CHD. The mass of an abnormally shaped left ventricle can be determined with high accuracy and low interobserver variability in patients with good or moderate echocardiographic image quality.
Collapse
Affiliation(s)
- Annemien E van den Bosch
- Department of Cardiology, Thoraxcenter, Erasmus Medical Centre, University Hospital, Rotterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
29
|
van den Bosch AE, Robbers-Visser D, Krenning BJ, Voormolen MM, McGhie JS, Helbing WA, Roos-Hesselink JW, Simoons ML, Meijboom FJ. Real-Time Transthoracic Three-Dimensional Echocardiographic Assessment of Left Ventricular Volume and Ejection Fraction in Congenital Heart Disease. J Am Soc Echocardiogr 2006; 19:1-6. [PMID: 16423662 DOI: 10.1016/j.echo.2005.06.009] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2005] [Indexed: 10/25/2022]
Abstract
OBJECTIVE The purpose of this study was to assess the (1) feasibility of real-time three-dimensional echocardiography (RT-3DE) data acquisition and (2) volumes and function of the abnormal left ventricle (LV) in adult patients with congenital heart disease (CHD), compared with magnetic resonance imaging (MRI) data. METHODS Thirty-two patients (59% were male) with CHD were evaluated on the same day by MRI and RT-3DE. Acquisition of RT-3DE data sets was feasible in 29 of the 32 patients (91%). The time of 3D data acquisition was 4 +/- 2 minutes, and LV analysis was 17 +/- 5 minutes per patient for manual border tracing. RESULTS A good correlation was observed between RT-3DE with manual border detection and MRI for LV end-diastolic volume (r = 0.97), LV end-systolic volume (r = 0.98), and LV ejection fraction (r = 0.94). CONCLUSION RT-3DE is feasible for volumetric analysis of the abnormal LV allowing accurate determination of LV volume and ejection fraction compared with MRI in adult patients with CHD.
Collapse
|
30
|
Biagini E, Schinkel AFL, Elhendy A, Bax JJ, Rizzello V, van Domburg RT, Krenning BJ, Schouten O, Branzi A, Rocchi G, Simoons ML, Poldermans D. Pacemaker stress echocardiography predicts cardiac events in patients with permanent pacemaker. Am J Med 2005; 118:1381-6. [PMID: 16378782 DOI: 10.1016/j.amjmed.2005.04.040] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2004] [Revised: 04/28/2005] [Accepted: 04/28/2005] [Indexed: 11/30/2022]
Abstract
PURPOSE Noninvasive pacemaker stress echocardiography is a newly introduced method for the diagnosis of coronary artery disease in patients with a permanent pacemaker. The prognostic value of pacemaker stress echocardiography has not been studied. SUBJECTS AND METHODS We studied 136 patients (mean age 64+/-12 years) with a permanent pacemaker who underwent pacemaker stress echocardiography for evaluation of coronary artery disease. All patients underwent pacemaker stress echocardiography by external programming (pacing heart rate up to ischemia or target heart rate). RESULTS Thirty-one patients (23%) had normal study results. Ischemia was detected in 75 patients (55%). During a mean follow-up of 3.5+/-2.4 years, 35 deaths (26%) (20 the result of cardiac causes) and 2 nonfatal myocardial infarctions (1%) occurred. The annual cardiac death rate was 1.3% in patients without ischemia and 4.6% in patients with ischemia (P=.01). The annual all-cause mortality rate was 3.1% in patients without ischemia and 7% in patients with ischemia (P=.004). The presence of ischemia during pacemaker stress echocardiography was the strongest independent predictor of cardiac death (hazard ratio 4.1, confidence interval 1.2-14.5) and all-cause mortality (hazard ratio 2.7, confidence interval 1.2-6.0) in a multivariable model. CONCLUSION Myocardial ischemia during pacemaker stress echocardiography is an independent predictor of cardiac death and all-cause mortality in patients with a permanent pacemaker.
Collapse
Affiliation(s)
- Elena Biagini
- Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
van Stralen M, Bosch JG, Voormolen MM, van Burken G, Krenning BJ, van Geuns RJM, Lancée CT, de Jong N, Reiber JHC. Left ventricular volume estimation in cardiac three-dimensional ultrasound: a semiautomatic border detection approach. Acad Radiol 2005; 12:1241-9. [PMID: 16179201 DOI: 10.1016/j.acra.2005.06.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2004] [Revised: 06/03/2005] [Accepted: 06/27/2005] [Indexed: 01/20/2023]
Abstract
RATIONALE AND OBJECTIVES We propose a semiautomatic endocardial border detection method for three-dimensional (3D) time series of cardiac ultrasound (US) data based on pattern matching and dynamic programming, operating on two-dimensional (2D) slices of the 3D plus time data, for the estimation of full cycle left ventricular volume, with minimal user interaction. MATERIALS AND METHODS The presented method is generally applicable to 3D US data and evaluated on data acquired with the Fast Rotating Ultrasound (FRU-) Transducer, developed by Erasmus Medical Center (Rotterdam, the Netherlands), a conventional phased-array transducer, rotating at very high speed around its image axis. The detection is based on endocardial edge pattern matching using dynamic programming, which is constrained by a 3D plus time shape model. It is applied to an automatically selected subset of 2D images of the original data set, for typically 10 equidistant rotation angles and 16 cardiac phases (160 images). Initialization requires the drawing of four contours per patient manually. We evaluated this method on 14 patients against MRI end-diastole and end-systole volumes. Initialization requires the drawing of four contours per patient manually. We evaluated this method on 14 patients against MRI end-diastolic (ED) and end-systolic (ES) volumes. RESULTS The semiautomatic border detection approach shows good correlations with MRI ED/ES volumes (r = 0.938) and low interobserver variability (y = 1.005x - 16.7, r = 0.943) over full-cycle volume estimations. It shows a high consistency in tracking the user-defined initial borders over space and time. CONCLUSIONS We show that the ease of the acquisition using the FRU-transducer and the semiautomatic endocardial border detection method together can provide a way to quickly estimate the left ventricular volume over the full cardiac cycle using little user interaction.
Collapse
Affiliation(s)
- Marijn van Stralen
- Division of Image Processing, Department of Radiology, C2S, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands.
| | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Biagini E, Elhendy A, Schinkel AFL, Rizzello V, Bax JJ, Sozzi FB, Kertai MD, van Domburg RT, Krenning BJ, Branzi A, Rapezzi C, Simoons ML, Poldermans D. Long-Term Prediction of Mortality in Elderly Persons by Dobutamine Stress Echocardiography. J Gerontol A Biol Sci Med Sci 2005; 60:1333-8. [PMID: 16282570 DOI: 10.1093/gerona/60.10.1333] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Dobutamine stress echocardiography (DSE) was shown to provide incremental prognostic information. However, its role in the prediction of mortality in elderly persons is not well defined. We assessed the value of DSE in the prediction of mortality and hard cardiac events during long-term follow-up in patients older than 65 years. METHODS We studied 1434 patients >65 years old (mean age 72 +/- 3 years) who underwent DSE for evaluation of coronary artery disease. Ischemia was defined as new or worsening wall motion abnormalities. Follow-up events were total mortality and hard cardiac events (cardiac mortality and nonfatal myocardial infarction). Multivariable Cox regression analysis was used to identify the independent predictors of follow-up events. RESULTS Ischemia was detected in 675 patients (47%). Five hundred six patients (35%) had a normal study, and 253 (18%) had fixed wall motion abnormalities. During a mean follow-up of 6.5 years, 532 (37%) deaths occurred, of which 249 (17%) were due to cardiac causes. A nonfatal myocardial infarction occurred in 45 patients (3%). Independent predictors of all-cause mortality in a multivariate analysis model were age (hazard ratio [HR] 1.06; 95% confidence interval [CI], 1.05-1.08), male sex (HR 1.5; 95% CI, 1.2-1.8), hypertension (HR 1.2; 95% CI, 1.1-1.4), smoking (HR 1.3; 95% CI, 1.1-1.6), diabetes (HR 1.4; 95% CI, 1.1-1.8), rest wall motion abnormalities (HR 1.07; 95% CI, 1.06-1.09), and ischemia (HR 1.3; 95% CI, 1.1-1.6). Independent predictors of hard cardiac events were age (HR 1.07; 95% CI, 1.05-1.09), male sex (HR 1.3; 95% CI, 1.1-1.7), smoking (HR 1.3; 95% CI, 1.1-1.6), diabetes (HR 1.6; 95% CI, 1.2-2.2), rest wall motion abnormalities (HR 1.13; 95% CI, 1.12-1.16), and ischemia (HR 2.1; 95% CI, 1.5-2.8). CONCLUSION DSE provides independent prognostic information to predict all-cause mortality and hard cardiac events in elderly patients.
Collapse
Affiliation(s)
- Elena Biagini
- Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Biagini E, Schinkel AFL, Bax JJ, Rizzello V, van Domburg RT, Krenning BJ, Bountioukos M, Pedone C, Vourvouri EC, Rapezzi C, Branzi A, Roelandt JRTC, Poldermans D. Long term outcome in patients with silent versus symptomatic ischaemia during dobutamine stress echocardiography. Heart 2005; 91:737-42. [PMID: 15894765 PMCID: PMC1768946 DOI: 10.1136/hrt.2004.041087] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVES To compare the long term prognosis of patients having silent versus symptomatic ischaemia during dobutamine stress echocardiography (DSE). DESIGN Observational study. SETTING Tertiary referral centre. PATIENTS 931 patients who experienced stress induced myocardial ischaemia during DSE. RESULTS Silent ischaemia was present in 643 of 931 patients (69%). The number of dysfunctional segments at rest (mean (SD) 9.6 (5.1) v 8.8 (5.0), p = 0.1) and of ischaemic segments (3.5 (2.2) v 3.8 (2.1), p = 0.2) was comparable in both groups. During a mean (SD) follow up of 5.5 (3.3) years, there were 169 (18%) cardiac deaths and 86 (9%) non-fatal infarctions. Multivariable Cox regression analysis showed age (hazard ratio (HR) 1.1, 95% confidence interval (CI) 1.02 to 1.05), previous myocardial infarction (HR 1.4, 95% CI 1.1 to 2.0), and number of ischaemic segments during the test (HR 2.0, 95% CI 1.0 to 3.7) as independent predictors of cardiac death and myocardial infarction. For every additional ischaemic segment there was a twofold increment in risk of late cardiac events. The annual cardiac death or myocardial infarction rate was 3.0% in patients with symptomatic ischaemia and 4.6% in patients with silent ischaemia (p < 0.01). Silent induced ischaemia was an independent predictor of cardiac death and myocardial infarction (HR 1.7, 95% CI 1.1 to 2.0). During follow up symptomatic patients were treated more often with cardioprotective therapy (p < 0.01) and coronary revascularisation (145 of 288 (50%) v 174 of 643 (27%), p < 0.001). CONCLUSIONS Patients with silent ischaemia had a similar extent of myocardial ischaemia during DSE compared to patients with symptomatic ischaemia but received less cardioprotective treatment and coronary revascularisation and experienced a higher cardiac event rate.
Collapse
Affiliation(s)
- E Biagini
- Department of Cardiology, Thoraxcentre, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
van den Bosch AE, Krenning BJ, Roelandt JRTC. Three-dimensional echocardiography. Minerva Cardioangiol 2005; 53:177-84. [PMID: 16003252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Three-dimensional (3-D) echocardiography has been an important research goal ever since the introduction of two-dimensional (2-D) echocardiography. Most approaches towards 3-D echocardiography were off-line and based on the sequential rotational scanning and acquisition of multiple cross-sectional images together with external or internal reference systems. These approaches were limited by long acquisition and analysis time in combination with poor image quality. Recently, improvements in the matrix array technology have significantly increased spatial and temporal resolution of second-generation real-time 3-D transducers. Clinical use of modern 3-D echocardiography is boosted by the marked reduction in acquisition time and the unique possibility of on-line rendering on the ultrasound system. The integration and future quantification of new parameters together with on-line review allows new insights into cardiac function, morphology and synchrony that offer great potentials in the evaluation of right and left global and regional function, diagnosis of small areas of ischemia, congenital and valvular heart disease and effects of biventricular pacing in dilated heart asynchrony. This report will review current and future applications of 3-D data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array transducer.
Collapse
Affiliation(s)
- A E van den Bosch
- Department of Cardiology, Thoraxcenter, Erasmus Medical Centre, Rotterdam, The Netherlands
| | | | | |
Collapse
|
35
|
de Groot-de Laat LE, Krenning BJ, ten Cate FJ, Roelandt JRTC. Usefulness of contrast echocardiography for diagnosis of left ventricular noncompaction. Am J Cardiol 2005; 95:1131-4. [PMID: 15842992 DOI: 10.1016/j.amjcard.2004.12.025] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2004] [Revised: 12/09/2004] [Accepted: 12/09/2004] [Indexed: 11/21/2022]
Abstract
Many imaging modalities have been evaluated for the diagnosis of left ventricular noncompaction (LVNC). Echocardiography with color Doppler flow imaging is currently the diagnostic modality of choice. In this study, the usefulness of contrast echocardiography to diagnose LVNC was examined, and the diagnostic criteria were evaluated.
Collapse
|
36
|
Biagini E, Elhendy A, Schinkel AFL, Rizzello V, van Domburg RT, Krenning BJ, Schouten O, Sozzi FB, Branzi A, Rocchi G, Simoons ML, Bax JJ, Poldermans D. Comparison of all-cause mortality in women with known or suspected coronary artery disease referred for dobutamine stress echocardiography with normal versus abnormal test results. Am J Cardiol 2005; 95:1072-5. [PMID: 15842974 DOI: 10.1016/j.amjcard.2004.12.061] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2004] [Revised: 12/16/2004] [Accepted: 12/16/2004] [Indexed: 11/19/2022]
Abstract
The presence of myocardial ischemia during dobutamine stress echocardiography is independently associated with an increased risk of all-cause mortality in women after adjustment for clinical data. This association is observed in patients who have proved coronary artery disease and in patients who have no history of coronary artery disease.
Collapse
Affiliation(s)
- Elena Biagini
- Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Krenning BJ, Szili-Torok T, Voormolen MM, Theuns DAMJ, Jordaens LJ, Lancée CT, De Jong N, Van Der Steen AFW, Ten Cate FJ, Roelandt JRTC. Guiding and optimization of resynchronization therapy with dynamic three-dimensional echocardiography and segmental volume-time curves: a feasibility study. Eur J Heart Fail 2005; 6:619-25. [PMID: 15302011 DOI: 10.1016/j.ejheart.2004.05.005] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2003] [Revised: 05/03/2004] [Accepted: 05/12/2004] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE To assess a new approach for guiding and hemodynamic optimization of resynchronization therapy, using three-dimensional (3D) transthoracic echocardiography. BACKGROUND Resynchronization therapy for heart failure provides the greatest hemodynamic benefit when applied to the most delayed left ventricular (LV) site. Currently, the ideal LV pacing site is selected according to acute invasive hemodynamic assessment and/or tissue Doppler imaging. METHODS A total of 16 patients with advanced heart failure and an implanted biventricular pacemaker were included in this study. Transthoracic apical LV images at equidistant intervals were obtained using a prototype, fast-rotating second harmonic transducer to reconstruct 3D LV datasets during sinus rhythm (SR), right ventricular (RV) apical and biventricular pacing mode. A semi-automated contour analysis system (4D LV analysis, TomTec, Germany) was used for segmental wall motion analysis and identification of the most delayed contracting segment and calculation of global LV function. RESULTS Data acquisition duration was 10 s and analyzable 3D images were obtained in 12 patients. Of these patients, data during SR were available in 9 and during biventricular pacing in 11. The greatest contraction delay during SR was found in the anterior and antero-septal segments in five of nine patients. Biventricular pacing resulted in reduction of the contraction delay in seven of eight patients. The global LV function did not change significantly. CONCLUSION 3D echocardiography with appropriate analytic software allows detection of the most delayed LV contracting segment and can be used to select the optimal pacing site during resynchronization therapy.
Collapse
Affiliation(s)
- Boudewijn J Krenning
- Erasmus Medical Center, Thoraxcenter, Room H536, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
van den Bosch AE, Krenning BJ, Roelandt DJRTC. Realtime Three-dimensional Echocardiography – A Perspective. Eur Cardiol 2005. [DOI: 10.15420/ecr.2005.1l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
39
|
van den Bosch AE, Krenning BJ, Roelandt DJRTC. Realtime Three-dimensional Echocardiography – A Perspective. Eur Cardiol 2005. [DOI: 10.15420/ecr.2005.30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
40
|
Biagini E, Elhendy A, Bax JJ, Rizzello V, Schinkel AFL, van Domburg RT, Kertai MD, Krenning BJ, Bountioukos M, Rapezzi C, Branzi A, Simoons ML, Poldermans D. Seven-year follow-up after dobutamine stress echocardiography. J Am Coll Cardiol 2005; 45:93-7. [PMID: 15629381 DOI: 10.1016/j.jacc.2004.09.048] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2004] [Revised: 09/14/2004] [Accepted: 09/16/2004] [Indexed: 10/26/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the effects of gender on long-term prognosis of patients undergoing dobutamine stress echocardiography (DSE). BACKGROUND Gender differences in the predictors of outcome among patients with known or suspected coronary artery disease undergoing DSE have not been adequately studied. METHODS We studied 2,276 men and 1,105 women with known or suspected coronary artery disease who underwent DSE. Follow-up events were cardiac death and nonfatal myocardial infarction (MI). RESULTS Dobutamine stress echocardiography was normal in 687 men (30%) and 483 women (44%) (p <0.0001). Ischemia on DSE was present in 1,194 men (52%) and 416 women (38%) (p <0.001). During a mean follow-up of 7 +/- 3.4 years, there were 894 (26%) deaths (442 attributed to cardiac causes) and 145 (4%) nonfatal MIs. The annual cardiac event rate was 2.5% in men and 1.2% in women with normal DSE. Independent predictors of cardiac events in patients with normal DSE using a Cox proportional hazards regression analysis were male gender (hazard ratio [HR]: 1.7 [range 1.1 to 2.8]), age (HR: 1.02 [range 1.01 to 1.04]), history of heart failure (HR: 3.4 [range 1.5 to 7.9]), previous MI (HR: 1.7 [range 1.1 to 2.8]), and diabetes (HR: 2.4 [range 1.3 to 4.5]). Independent predictors of cardiac events in patients with an abnormal DSE were age (HR: 1.03 [range 1.02 to 1.04]), history of heart failure (HR: 1.7 [range 1.3 to 2.1]), diabetes (HR: 1.4 [range 1.1 to 1.8]), heart rate at rest (HR: 2.8 [range 1.4 to 5.8]), wall motion abnormalities at rest (HR: 1.06 [range 1.04 to 1.09]), and ischemia on DSE (HR: 1.04 [range 1.02 to 1.07]). Myocardial ischemia was an independent predictor of cardiac events in both men and women. CONCLUSIONS Dobutamine stress echocardiography provides independent prognostic information in both men and women. In patients with normal DSE, gender is independently associated with cardiac events. The outcome of patients with abnormal DSE is not related to gender, after adjusting for stress echocardiographic abnormalities.
Collapse
Affiliation(s)
- Elena Biagini
- Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Bountioukos M, Schinkel AFL, Bax JJ, Biagini E, Rizzello V, Krenning BJ, Vourvouri EC, Roelandt JRTC, Poldermans D. Pulsed-wave tissue Doppler quantification of systolic and diastolic function of viable and nonviable myocardium in patients with ischemic cardiomyopathy. Am Heart J 2004; 148:1079-84. [PMID: 15632896 DOI: 10.1016/j.ahj.2004.05.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Detection of myocardial viability is crucial for clinical treatment of patients with ischemic cardiomyopathy. Currently, quantitative information for the evaluation of systolic and diastolic function of viable tissue is limited. Our aim was to compare quantitatively systolic and diastolic function in viable and nonviable dysfunctional myocardium in patients with ischemic cardiomyopathy. METHODS A total of 93 patients (mean age, 62 +/- 10 years) underwent dobutamine stress echocardiography to assess myocardial viability. Pulsed-wave tissue Doppler imaging (TDI) was used to assess systolic ejection velocity (V(S)) and early (V(E)) and late (V(A)) diastolic velocities at rest and at low-dose dobutamine infusion (10 microg/kg per minute) in viable and nonviable dysfunctional regions. Analysis was repeated after dividing study population in patients >or=65 years old (n = 40) and <65 years old (n = 53). RESULTS Pulsed-wave TDI demonstrated that V(S) was comparable in dysfunctional viable and nonviable regions at rest (V(S), 6.3 +/- 1.9 cm/s vs 6.3 +/- 2.0 cm/s, respectively, P = .93). However, at low-dose dobutamine challenge, V(S) was significantly higher in viable regions (8.5 +/- 2.7 cm/s vs 7.8 +/- 2.4 cm/s, P = .002). Viable regions had higher V(E) at rest compared with nonviable regions (8.4 +/- 2.5 cm/s vs 7.5 +/- 2.8 cm/s, P = .003). Myocardial velocities were significantly higher in patients >or=65 years old, both in viable and nonviable regions. CONCLUSIONS Quantification of myocardial motion by pulsed-wave TDI demonstrates that at low-dose dobutamine stress, systolic velocity is markedly improved in viable myocardium, indicating the presence of contractile reserve in viable regions. A superior early diastolic filling at rest can also differentiate viable from nonviable myocardium.
Collapse
Affiliation(s)
- Manolis Bountioukos
- Thoraxcenter, Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Biagini E, Schinkel AFL, Rizzello V, van Domburg RT, Pedone C, Elhendy A, Krenning BJ, Bountioukos M, Vourvouri EC, Branzi A, Rapezzi C, Simoons ML, Bax JJ, Poldermans D. Prognostic stratification of patients with right bundle branch block using dobutamine stress echocardiography. Am J Cardiol 2004; 94:954-7. [PMID: 15464688 DOI: 10.1016/j.amjcard.2004.06.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2004] [Revised: 06/25/2004] [Accepted: 06/25/2004] [Indexed: 11/23/2022]
Abstract
The presence of a right bundle branch block (RBBB) is associated with increased mortality. We studied the role of dobutamine stress echocardiography for the prognostic stratification of patients with RBBB. The presence of an abnormal dobutamine stress echocardiography was the strongest predictor of cardiac events and provided incremental prognostic information to clinical and stress test data.
Collapse
Affiliation(s)
- Elena Biagini
- Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Bountioukos M, Elhendy A, van Domburg RT, Schinkel AFL, Bax JJ, Krenning BJ, Biagini E, Rizzello V, Simoons ML, Poldermans D. Prognostic value of dobutamine stress echocardiography in patients with previous coronary revascularisation. Heart 2004; 90:1031-5. [PMID: 15310692 PMCID: PMC1768408 DOI: 10.1136/hrt.2003.029025] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE To assess the prognostic value of dobutamine stress echocardiography (DSE) in patients with previous myocardial revascularisation. DESIGN Prospective study. SETTING Tertiary referral centre in Rotterdam, the Netherlands. PATIENTS 332 consecutive patients with previous percutaneous or surgical coronary revascularisation underwent DSE. Follow up was successful for 331 (99.7%) patients. Thirty eight patients who underwent early revascularisation (<or= 3 months) after the test were excluded from analysis. MAIN OUTCOME MEASURES Cox proportional hazards regression models were used to identify independent predictors of the composite of cardiac events (cardiac death, non-fatal myocardial infarction, and late revascularisation). RESULTS During a mean (SD) of 24 (20) months, 37 (13%) patients died and 89 (30%) had at least one cardiac event (21 (7%) cardiac deaths, 11 (4%) non-fatal myocardial infarctions, and 68 (23%) late revascularisations). In multivariate analysis of clinical data, independent predictors of late cardiac events were hypertension (hazard ratio (HR) 1.7, 95% confidence interval (CI) 1.1 to 2.6) and congestive heart failure (HR 2.1, 95% CI 1.3 to 3.2). Reversible wall motion abnormalities (ischaemia) on DSE were incrementally predictive of cardiac events (HR 2.1, 95% CI 1.3 to 3.2). CONCLUSIONS Myocardial ischaemia during DSE is independently predictive of cardiac events among patients with previous myocardial revascularisation, after controlling for clinical data.
Collapse
Affiliation(s)
- M Bountioukos
- Thoraxcentre, Department of Cardiology, Erasmus Medical Centre, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
de Laat LE, Galema TW, Krenning BJ, Roelandt JR. Diagnosis of non-compaction cardiomyopathy with contrast echocardiography. Int J Cardiol 2004; 94:127-8. [PMID: 14996488 DOI: 10.1016/j.ijcard.2003.04.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2002] [Accepted: 04/02/2003] [Indexed: 11/30/2022]
|
45
|
Krenning BJ, Van Den Bosch AE, Poldermans D. [Clinical reasoning and decision-making in practice. A 76 year old woman with gastric carcinoma and cardiac valve disease]. Ned Tijdschr Geneeskd 2004; 148:1468-9; author reply 1469. [PMID: 15310036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
|
46
|
Bountioukos M, Schinkel AFL, Poldermans D, Rizzello V, Vourvouri EC, Krenning BJ, Biagini E, Roelandt JRTC, Bax JJ. QT dispersion correlates to myocardial viability assessed by dobutamine stress echocardiography in patients with severely depressed left ventricular function due to coronary artery disease. Eur J Heart Fail 2004; 6:187-93. [PMID: 14984726 DOI: 10.1016/j.ejheart.2003.09.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2003] [Revised: 05/29/2003] [Accepted: 09/15/2003] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND QT dispersion is prolonged in numerous cardiac diseases, representing a general repolarization abnormality. AIM To evaluate the influence of viable myocardium on QT dispersion in patients with severely depressed left ventricular (LV) function due to coronary artery disease. METHODS AND RESULTS 103 patients with ischemic cardiomyopathy (LV ejection fraction [EF]: 25+/-6%) were studied. Patients underwent 12-lead electrocardiography to assess QT dispersion, and two-dimensional echocardiography to identify segmental dysfunction. Dobutamine stress echocardiography (DSE) was then performed to detect residual viability. Resting echo demonstrated 1260 dysfunctional segments; of these, 476 (38%) were viable. Substantial viability (> or =4 viable segments on DSE) was found in 62 (60%) patients. QT dispersion was lower in these patients, than in patients without viability (55+/-17 ms vs. 65+/-22 ms, P=0.012). Viable segments negatively correlated to QT dispersion (r=-0.333, P=0.001). In contrast, there was no correlation between LVEF and QT dispersion (r=-0.001, P=NS). CONCLUSIONS There is a negative correlation between QT dispersion and the number of viable segments assessed by DSE. Patients with severely depressed LV function and a low QT dispersion probably have a substantial amount of viable tissue. Conversely, when QT dispersion is high, the likelihood of substantial viability is reduced.
Collapse
Affiliation(s)
- Manolis Bountioukos
- Thoraxcenter, Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Bountioukos M, Schinkel AFL, Bax JJ, Rizzello V, Valkema R, Krenning BJ, Biagini E, Vourvouri EC, Roelandt JRTC, Poldermans D. Pulsed wave tissue Doppler imaging for the quantification of contractile reserve in stunned, hibernating, and scarred myocardium. Heart 2004; 90:506-10. [PMID: 15084544 PMCID: PMC1768236 DOI: 10.1136/hrt.2003.018531] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
OBJECTIVES To assess whether quantification of myocardial systolic velocities by pulsed wave tissue Doppler imaging can differentiate between stunned, hibernating, and scarred myocardium. DESIGN Observational study. SETTING Tertiary referral centre. PATIENTS 70 patients with reduced left ventricular function caused by chronic coronary artery disease. METHODS Pulsed wave tissue Doppler imaging was done close to the mitral annulus at rest and during low dose dobutamine; systolic ejection velocity (Vs) and the difference in Vs between low dose dobutamine and the resting value (DeltaVs) were assessed using a six segment model. Assessment of perfusion (with Tc-99m-tetrofosmin SPECT) and glucose utilisation (by 18F-fluorodeoxyglucose SPECT) was used to classify dysfunctional regions (by resting cross sectional echocardiography) as stunned, hibernating, or scarred. RESULTS 253 of 420 regions (60%) were dysfunctional. Of these, 132 (52%) were classified as stunned, 25 (10%) as hibernating, and 96 (38%) as scarred. At rest, Vs in stunned, hibernating, and scar tissue was, respectively, 6.3 (1.8), 6.6 (2.2), and 5.5 (1.5) cm/s (p = 0.001 by ANOVA). There was a gradual decline in Vs during low dose dobutamine infusion between stunned, hibernating, and scar tissue (8.3 (2.6) v 7.8 (1.5) v 6.8 (1.9) cm/s, p < 0.001 by ANOVA). DeltaVs was higher in stunned (2.1 (1.9) cm/s) than in hibernating (1.2 (1.4) cm/s, p < 0.05) or scarred regions (1.3 (1.2) cm/s, p = 0.001). CONCLUSIONS Quantitative tissue Doppler imaging showed a gradual reduction in regional velocities between stunned, hibernating, and scarred myocardium. Dobutamine induced contractile reserve was higher in stunned regions than in hibernating and scarred myocardium, reflecting different severities of myocardial damage.
Collapse
Affiliation(s)
- M Bountioukos
- Thoraxcenter, Department of Cardiology, Erasmus MC, Rotterdam, Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
Improved endocardial border delineation with the application of contrast agents should allow for less complex and faster tracing algorithms for left ventricular volume analysis. We developed a fast rotating phased array transducer for 3D imaging of the heart with harmonic capabilities making it suitable for contrast imaging. In this study the feasibility of 3D harmonic contrast imaging is evaluated in vitro. A commercially available tissue mimicking flow phantom was used in combination with Sonovue. Backscatter power spectra from a tissue and contrast region of interest were calculated from recorded radio frequency data. The spectra and the extracted contrast to tissue ratio from these spectra were used to optimize the excitation frequency, the pulse length and the receive filter settings of the transducer. Frequencies ranging from 1.66 to 2.35 MHz and pulse lengths of 1.5, 2 and 2.5 cycles were explored. An increase of more than 15 dB in the contrast to tissue ratio was found around the second harmonic compared with the fundamental level at an optimal excitation frequency of 1.74 MHz and a pulse length of 2.5 cycles. Using the optimal settings for 3D harmonic contrast recordings volume measurements of a left ventricular shaped agar phantom were performed. Without contrast the extracted volume data resulted in a volume error of 1.5%, with contrast an accuracy of 3.8% was achieved. The results show the feasibility of accurate volume measurements from 3D harmonic contrast images. Further investigations will include the clinical evaluation of the presented technique for improved assessment of the heart.
Collapse
Affiliation(s)
- M M Voormolen
- ICIN, Interuniversity Cardiology Institute of the Netherlands, Utrecht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
49
|
Szili-Torok T, Krenning BJ, Voormolen MM, Roelandt JRTC. Dynamic three-dimensional echocardiography combined with semi-automated border detection offers advantages for assessment of resynchronization therapy. Cardiovasc Ultrasound 2003; 1:14. [PMID: 14613577 PMCID: PMC270011 DOI: 10.1186/1476-7120-1-14] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2003] [Accepted: 10/21/2003] [Indexed: 11/25/2022] Open
Abstract
Simultaneous electrical stimulation of both ventricles in patients with interventricular conduction disturbance and advanced heart failure improves hemodynamics and results in increased exercise tolerance, quality of life. We have developed a novel technique for the assessment and optimization of resynchronization therapy. Our approach is based on transthoracic dynamic three-dimensional (3D) echocardiography and allows determination of the most delayed contraction site of the left ventricle (LV) together with global LV function data. Our initial results suggest that fast reconstruction of the LV is feasible for the selection of the optimal pacing site and allows identifying LV segments with dyssynchrony.
Collapse
MESH Headings
- Arrhythmias, Cardiac/complications
- Arrhythmias, Cardiac/diagnostic imaging
- Arrhythmias, Cardiac/therapy
- Artificial Intelligence
- Cardiac Pacing, Artificial/methods
- Echocardiography, Three-Dimensional/methods
- Feasibility Studies
- Humans
- Image Enhancement/methods
- Image Interpretation, Computer-Assisted/methods
- Online Systems
- Pattern Recognition, Automated/methods
- Prognosis
- Therapy, Computer-Assisted/methods
- Treatment Outcome
- Ventricular Dysfunction, Left/diagnostic imaging
- Ventricular Dysfunction, Left/etiology
- Ventricular Dysfunction, Left/prevention & control
Collapse
Affiliation(s)
- Tamas Szili-Torok
- Thoraxcentre, Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| | | | - Marco M Voormolen
- Thoraxcentre, Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| | - Jos RTC Roelandt
- Thoraxcentre, Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
50
|
Abstract
Accurate determination of LV volume, ejection fraction and segmental wall motion abnormalities is important for clinical decision-making and follow-up assessment. Currently, echocardiography is the most common used method to obtain this information. Three-dimensional echocardiography has shown to be an accurate and reproducible method for LV quantitation, mainly by avoiding the use of geometric assumptions. In this review, we describe various methods to acquire a 3D-dataset for LV volume and wall motion analysis, including their advantages and limitations. We provide an overview of studies comparing LV volume and function measurement by various gated and real-time methods of acquisition compared to magnetic resonance imaging. New technical improvements, such as automated endocardial border detection and contrast enhancement, will make accurate on-line assessment with little operator interaction possible in the near future.
Collapse
Affiliation(s)
| | - Marco M Voormolen
- Department of Cardiology, Thoraxcentre, Erasmus MC, Rotterdam, The Netherlands
| | - Jos RTC Roelandt
- Department of Cardiology, Thoraxcentre, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|