1
|
Abstract
Abstract
Creatine kinase (CK; EC 2.7.3.2) catalytic activity in serum is widely measured in clinical chemistry practice and provides information for diagnosis and follow-up in many pathological conditions affecting heart, muscle, and brain. Depending on the organ involved, the predominant CK isoenzyme in serum varies. However, routine methods measure total CK catalytic activity, and standardized methods for doing so have been recommended by the International Federation of Clinical Chemistry and by several national scientific societies. Many commercial kits for those methods are now available. With use of a reference material for CK, commercial reagents can be compared with standardized methods, improving confidence in the results. Here we present a reference preparation of CK consisting of the BB isoenzyme purified from human placentae. We describe the procedure of purification and the properties of the lyophilized preparation of CK-BB, which has been certified by the Community Bureau of Reference of the Commission of the European Communities under the designation CRM 299. The preparation can be used to calibrate assays of the catalytic activity of CK-MM and CK-MB, as well as CK-BB.
Collapse
Affiliation(s)
- M Mathieu
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | - J P Steghens
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | - M Hørder
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | - D W Moss
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | - E Colinet
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | - C Profilis
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| |
Collapse
|
2
|
Sánchez M, Gella FJ, Profilis C, Ceriotti F, Cusó E, Fuentes-Arderiu X, Hallermayer K, Hørder M, Panteghini M, Schumann G, Canalias F. Certification of the mass concentration of creatine kinase isoenzyme 2 (CK-MB) in the reference material BCR 608. Clin Chem Lab Med 2001; 39:858-65. [PMID: 11601686 DOI: 10.1515/cclm.2001.142] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
We describe the certification of a mass concentration value in the already prepared creatine kinase-2 reference material (BCR 608). Creatine kinase-2 was purified from human heart. The purified enzyme was diluted in order to measure its protein concentration by the Doetsch method. A protein concentration value of 124.30+/-13.17 mg/l was assigned to the stock solution of purified creatine kinase-2. This stock solution was diluted in 25 mmol/l piperazine-N,N'-bis[2-ethanesulfonic acid] (PIPES) pH 7.2, containing 2 mmol/l ADP, 5 mmol/l 2-mercaptoethanol, 154 mmol/l sodium chloride and 50 g/l human albumin to obtain a stable liquid standard of known creatine kinase-2 mass concentration (80.36 microg/l). This standard was then used to recalculate the creatine kinase-2 mass concentration measured in the BCR 608 material by immunoassay. The mass concentration of creatine kinase-2 in samples of reconstituted BCR 608 was certified to be 93.30+/-9.65 microg/l.
Collapse
Affiliation(s)
- M Sánchez
- Departament de Bioquimica i de Biologia Molecular, Unitat de Bioquímica de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Bota A, Gella FJ, Profilis C, Férard G, Hadjivassiliou AG, Hørder M, Schiele F, Segura R, Canalias F. Production and certification of an enzyme reference material for adenosine deaminase 1 (BCR 647). Clin Chim Acta 2001; 306:79-89. [PMID: 11282097 DOI: 10.1016/s0009-8981(01)00399-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND We describe the preparation of a lyophilised reference material containing purified human adenosine deaminase 1 and the certification of its catalytic concentration. METHODS The enzyme was purified from human erythrocytes. RESULTS The enzyme was >99% pure on polyacrylamide gel electrophoresis. Only trace amounts (<0.4%) of alanine aminotransferase, aspartate aminotransferase and L-lactate dehydrogenase were detected in the purified fraction. The purified adenosine deaminase had a molar mass of 41600 g/mol and an isoelectric pH at 4.7, 4.85 and 5.0. The material was prepared by diluting the purified adenosine deaminase in a matrix containing 50 mmol/l Tris-HCl buffer pH 7.4 and 30 g/l human serum albumin; dispensing in vials and freeze-drying. The batch was homogeneous and the predicted loss of adenosine deaminase activity per year on the basis of accelerated degradation studies was 0.006% at -20 degrees C and 0.04% at 4 degrees C. The certified value for adenosine deaminase catalytic concentration in the reconstituted reference material is (2.55+/-0.09) microkat/l when measured by the method that uses adenosine as substrate and glutamate dehydrogenase as auxiliary enzyme at 37 degrees C. CONCLUSIONS The material can be used to verify the comparability of results from different laboratories, for intra-laboratory quality control, or for calibration of the adenosine deaminase catalytic concentration measurements.
Collapse
Affiliation(s)
- A Bota
- Departament de Bioquímica i de Biologia Molecular, Unitat de Bioquímica de Medicina, Universitat Autònoma de Barcelona, Edifici M, 08193 Bellaterra, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Gubern G, Canalias F, Gella FJ, Colinet E, Profilis C, Calam DH, Ceriotti F, Dufaux J, Hadjivassiliou AG, Lessinger JM, Lorentz K, Vassault A. Production and certification of an enzyme reference material for pancreatic alpha-amylase (CRM 476). Clin Chim Acta 1996; 251:145-62. [PMID: 8862470 DOI: 10.1016/0009-8981(96)06302-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We describe the preparation of a lyophilized material containing purified human pancreatic alpha-amylase and the certification of its catalytic concentration. The enzyme was purified from human pancreas by ammonium sulphate precipitation and chromatography successively on DEAE-Sephacel, CM-Sepharose and Sephadex G-75. The purified enzyme had a specific activity of 52.9 kU/g protein and was > 99% pure on polyacrylamide gel electrophoresis. Only trace amounts of lipase and lactate dehydrogenase were detected in the purified fraction. The purified pancreatic alpha-amylase had a molar mass of 57,500 g/mol and an isoelectric point at 7.1. The material was prepared by diluting the purified alpha-amylase in a matrix containing PIPES buffer 25 mmol/l, pH 7.0, sodium chloride 50 mmol/l, calcium chloride 1.5 mmol/l, EDTA 0.5 mmol/l and human serum albumin 30 g/l, dispensing in ampoules and freeze-drying. The ampoules were homogeneous and the yearly loss of activity on the basis of accelerated degradation studies was less than 0.01% at -20 degrees C. The certified value for alpha-amylase catalytic concentration in the reconstituted reference material is 555 U/l +/- 11 U/l when measured by the specified method at 37 degrees C. The material can be used to verify the comparability of results from laboratories, for intra-laboratory quality control or for calibration of alpha-amylase catalytic concentration measurements.
Collapse
Affiliation(s)
- G Gubern
- Department de Bioquímica i Biologia Molecular, Universitat Autonòma de Barcelona, Spain
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Feldt-Rasmussen U, Profilis C, Colinet E, Black E, Bornet H, Bourdoux P, Carayon P, Ericsson UB, Koutras DA, Lamas de Leon L, DeNayer P, Pacini F, Palumbo G, Santos A, Schlumberger M, Seidel C, Van Herle AJ, DeVijlder JJ. Human thyroglobulin reference material (CRM 457). 2nd Part: Physicochemical characterization and certification. Ann Biol Clin (Paris) 1996; 54:343-8. [PMID: 9092301 DOI: pmid/9092301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This report describes the characterization of a purified human thyroglobulin (Tg) reference material, and details the procedures used in its certification. The purified Tg is intended to be used as a primary reference material to establish calibration of working serum based reference material for immunoassay procedures. The programme involved the participation of 15 European laboratories and one laboratory from the United States. The physicochemical characterization showed by polyacrylamide gel electrophoresis and immunoblotting that the purified Tg had for the major part the expected molecular size of 660 kDa with traces of lower molecular forms. The amino acid composition was close to that demonstrated for the cDNA and the content of iodine was in keeping with a moderately to highly iodinated Tg. The mass concentration in reference material RM 457 is certified to be (0.324 +/- 0.018) g/L on the basis of protein determined by the Lowry method and supported by nitrogen determination, absorbance measurement, and amino acid analysis. This reference material is considered the first step towards decreasing the interlaboratory variability between Tg methods of measurement.
Collapse
Affiliation(s)
- U Feldt-Rasmussen
- Department of Medicine, National University Hospital, Copenhagen, Denmark
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Feldt-Rasmussen U, Profilis C, Colinet E, Black E, Bornet H, Bourdoux P, Carayon P, Ericsson UB, Koutras DA, Lamas de Leon L, DeNayer P, Pacini F, Palumbo G, Santos A, Schlumberger M, Seidel C, Van Herle AJ, De Vijlder JJ. Human thyroglobulin reference material (CRM 457). 1st Part: Assessment of homogeneity, stability and immunoreactivity. Ann Biol Clin (Paris) 1996; 54:337-42. [PMID: 9092300 DOI: pmid/9092300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This paper describes the assessment of the homogeneity and stability of a purified and lyophilized human thyroglobulin (Tg), and characterizes its immunoreactivity. The purified and lyophilized Tg is intended to be used as a primary reference material to establish calibration of working serum based reference material. The programme involved the participation of 15 European laboratories and one laboratory from the United States. The homogeneity of the content of the ampoules was considered acceptable (< 9%). The stability was tested by accelerated temperature degradation showing predicted annual relative losses of 0.01% at -70 degrees C and 1.04% at -20 degrees C. The immunoreactivity of the Tg material as measured in different laboratories varied mostly according to the method used rather than the laboratory. The interlaboratory variability showed that the two commercial methods used in several laboratories (kit 1 and 2) had an interlaboratory variation (CV) of 15.9% (N = 5) and 7.1% (N = 3), respectively, whereas the total interlaboratory CV was 64.3% (N = 18). The immunoreactive Tg had dilution curves parallel with other Tg calibrators (those of the methods). Dilution curves of the Tg material after storage at various temperatures and time were parallel in both RIA and IRMA. In conclusion, we have prepared a Tg reference material which in extensive studies in several participating laboratories has demonstrated a sufficient homogeneity and stability as well as dilution curves parallel to the calibrators of all the immunoassays tested in the study. This reference material is considered the first step towards decreasing the interlaboratory variability between Tg immunoassays.
Collapse
Affiliation(s)
- U Feldt-Rasmussen
- Department of Medicine, National University Hospital, Copenhagen, Denmark
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Mathieu M, Steghens JP, Hørder M, Moss DW, Colinet E, Profilis C. A reference preparation of creatine kinase BB isoenzyme. Clin Chem 1993; 39:1894-8. [PMID: 8375067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Creatine kinase (CK; EC 2.7.3.2) catalytic activity in serum is widely measured in clinical chemistry practice and provides information for diagnosis and follow-up in many pathological conditions affecting heart, muscle, and brain. Depending on the organ involved, the predominant CK isoenzyme in serum varies. However, routine methods measure total CK catalytic activity, and standardized methods for doing so have been recommended by the International Federation of Clinical Chemistry and by several national scientific societies. Many commercial kits for those methods are now available. With use of a reference material for CK, commercial reagents can be compared with standardized methods, improving confidence in the results. Here we present a reference preparation of CK consisting of the BB isoenzyme purified from human placentae. We describe the procedure of purification and the properties of the lyophilized preparation of CK-BB, which has been certified by the Community Bureau of Reference of the Commission of the European Communities under the designation CRM 299. The preparation can be used to calibrate assays of the catalytic activity of CK-MM and CK-MB, as well as CK-BB.
Collapse
Affiliation(s)
- M Mathieu
- Hospices Civils de Lyon, Hôpital Debrousse, Service de Biochimie, France
| | | | | | | | | | | |
Collapse
|