1
|
Martinez-Aviño A, Moliner-Martinez Y, Molins-Legua C, Campins-Falcó P. Colorimetric analysis platform based on thin layer chromatography for monitoring gluten cross-contamination in food industry. Food Chem 2024; 448:139025. [PMID: 38522293 DOI: 10.1016/j.foodchem.2024.139025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 03/08/2024] [Accepted: 03/10/2024] [Indexed: 03/26/2024]
Abstract
Monitoring of the accidental presence of gluten (Glu), resulting from cross-contamination, is imperative in different industries, in particular food industry. The objective of this study was the development of an analytical platform utilizing thin-layer chromatography (TLC) with colorimetric read-out for making binary (yes/no) decisions on surfaces and/or point of these industries. The composition of the extractive phase was optimized with commercial products used in cleaning processing lines. Subsequently, an exploration of TLC separation and detection was undertaken. CN-modified nanosilica plates and 30:70 acetonitrile:water were used to achieve a selective signal for Glu residues. The study of the detection performance showed that both spectroscopic measurement and image analysis were resulted in satisfactory results for quantitate analysis (RSD = 5 %, LOD = 0.12 mg). The practical application of the proposed methodology on surfaces of the food processing lines. This work demonstrated the operational feasibility in detecting gluten cross-contaminations within the food processing industry.
Collapse
Affiliation(s)
- A Martinez-Aviño
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, 46100 Burjassot, Spain
| | - Y Moliner-Martinez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, 46100 Burjassot, Spain.
| | - C Molins-Legua
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, 46100 Burjassot, Spain
| | - P Campins-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, 46100 Burjassot, Spain
| |
Collapse
|
2
|
Buj-Acosta C, García-Sanz V, Hakobyan L, Tarazona-Álvarez B, Molins-Legua C, Campins-Falcó P, Paredes-Gallardo V, Tortajada-Girbés M. Volatile sulfur compounds in asthmatic children and adolescents: A cross-sectional study in breath and saliva. Int J Paediatr Dent 2024. [PMID: 38514460 DOI: 10.1111/ipd.13178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 01/15/2024] [Accepted: 02/28/2024] [Indexed: 03/23/2024]
Abstract
BACKGROUND Halitosis in children implies psychosocial repercussions. Risk factors associated with this condition are unclear, and detection methods are inaccurate. AIM To quantify the levels of sulfur-like compounds in children with asthma and healthy children from a novel validated assay, and to establish the risk factors related to halitosis. DESIGN One hundred and twenty-eight individuals (63 healthy and 65 asthmatic) from 3 to 17 years of age were tested using a passive colorimetric sensor to measure the levels of sulfur-like compounds in breath and saliva. Information was collected on oral hygiene habits, gingival and dental health, breathing type, and dental malocclusion. RESULTS The mean values of hydrogen sulfide were 4.0 ± 6.8 and 19.7 ± 12.2 ppbv (parts per billion in volume) in the control and asthmatic groups, respectively (p < .001). The presence of higher concentrations of sulfur compounds was significantly associated (p < .05) with the presence of gingival inflammation, tongue coating, dental plaque, mouth breathing, hypomineralization, age, tongue brushing, and the use of dental floss. CONCLUSION The level of sulfur in breath and saliva was significantly higher in patients with asthma. These results can serve as a precedent to raise awareness among paediatricians and parents about oral hygiene care in children and adolescents.
Collapse
Affiliation(s)
- Cindy Buj-Acosta
- Department of Stomatology, University of Valencia, Valencia, Spain
| | | | - Lusine Hakobyan
- MINTOTA Research Group, Department of Analytical Chemistry, University of Valencia, Valencia, Spain
| | | | - Carmen Molins-Legua
- MINTOTA Research Group, Department of Analytical Chemistry, University of Valencia, Valencia, Spain
| | - Pilar Campins-Falcó
- MINTOTA Research Group, Department of Analytical Chemistry, University of Valencia, Valencia, Spain
| | | | | |
Collapse
|
3
|
Cortés-Bautista S, Robles-Jimárez HR, Carrero-Ferrer I, Molins-Legua C, Campíns-Falcó P. Portable determinations for legislated dissolved nitrogen forms in several environmental water samples as a study case. Sci Total Environ 2023; 864:161131. [PMID: 36566864 DOI: 10.1016/j.scitotenv.2022.161131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 11/28/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
In this work, we have studied the main species involved in determining total dissolved nitrogen (TDN) in water samples for accommodating a variety of quantitation methodologies to portable instruments and with the goal to achieve in situ analysis. The rise of water eutrophication is becoming an ecological problem in the world and TDN contributes markedly to this. Traditionally the several forms of DN are measured in the laboratory using conventional instrumentation from grab samples, but their analysis in place and in real time is a current demand. Inorganic nitrogen: NO3-, NO2- and NH4+, and organic nitrogen, such as amino nitrogen were tested here. For nitrate that presents native UV absorption suitable for direct water analysis, a portable optical fiber probe was compared with benchtop equipment and an in place analyzer. For nitrate, nitrite and ammonium, in situ solid devices that deliver reagents needed were tested and water color was measured by a smartphone coupled with a miniaturized optical fiber spectrometer and a miniaturized spectrometer or from images obtained and their RGB components. Amino nitrogen of some aromatic aminoacids with native fluorescence was followed by a portable optical fiber probe. Organic amino nitrogen and ammonium were determined by a portable luminometer and luminol supported in a measurement tube. Moreover, a portable miniaturized liquid chromatograph was shown suitable for monitoring priority nitrogen environmental pollutants. All options provided suitable results in comparison with lab estimations and were useful for evaluating if the legislation is fulfilled for the variety of tested waters. A discussion about the several portable options proposed for in place analysis, in function of the legislated determinations needed for each type of water was carried out.
Collapse
Affiliation(s)
- S Cortés-Bautista
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain
| | - H R Robles-Jimárez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain
| | - I Carrero-Ferrer
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain
| | - C Molins-Legua
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, València, Spain.
| |
Collapse
|
4
|
Hakobyan L, Monforte-Gómez B, Moliner-Martínez Y, Molins-Legua C, Campíns-Falcó P. Improving Sustainability of the Griess Reaction by Reagent Stabilization on PDMS Membranes and ZnNPs as Reductor of Nitrates: Application to Different Water Samples. Polymers (Basel) 2022; 14:polym14030464. [PMID: 35160454 PMCID: PMC8839667 DOI: 10.3390/polym14030464] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/17/2022] [Accepted: 01/20/2022] [Indexed: 01/25/2023] Open
Abstract
A new approach based on the use of polydimethylsiloxane (PDMS) membranes doped with Griess reagents for in situ determination of NO2− and NO3−- in real samples is proposed. The influence of some doping compounds, on the properties of the PDMS membranes, such as tetraethyl orthosilicate (TEOS), or/and ionic liquids (OMIM PF6) has been studied. Membrane characterization was performed. To apply the procedure to NO3− determination, dispersed Zn nanoparticles (ZnNPs) were employed. The analytical responses were the absorbance or the RGB components from digital images. Good precision (RSD < 8%) and detection limit of 0.01 and 0.5 mgL−1 for NO2− and NO3−, respectively, were achieved. The approach was satisfactory when applied to the determination of NO2− and NO3− in drinking waters, irrigation and river waters, and waters from canned and fresh vegetables. The results obtained were statistically comparable with those by using nitrate ISE or UV measurement. This approach was transferred satisfactory to 96 wells for multianalysis. This study enables the improvement in the on-site determination of NO2− and NO3− in several matrices. It is a sustainable alternative over the reagent derivatizations in solution and presents several advantages such as being versatile, simplicity, low analysis time, cost, and energy efficiency. The response can be detected visually or by portable instruments such as smartphone.
Collapse
|
5
|
Robles-Jimarez HR, Sanjuan-Navarro L, Jornet-Martínez N, Primaz CT, Teruel-Juanes R, Molins-Legua C, Ribes-Greus A, Campíns-Falcó P. New silica based adsorbent material from rice straw and its in-flow application to nitrate reduction in waters: Process sustainability and scale-up possibilities. Sci Total Environ 2022; 805:150317. [PMID: 34818774 DOI: 10.1016/j.scitotenv.2021.150317] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 09/08/2021] [Accepted: 09/09/2021] [Indexed: 06/13/2023]
Abstract
This paper shows a particular example to move to a sustainable circular economical process from valorization of rice straw ashes by developing a green synthesis for obtaining a useful sub-product. This strategy can palliate negative effects of the agriculture waste practices on the environment and also the obtained silica reduced nitrate content in waters. It is demonstrated that the silica synthesis developed at lab was scalable more than a hundred times with good results. Adsorption studies of nitrate in standards and real well waters at lab scale and scaling-up provided similar results. Adsorption values near to 15 mg/g for nitrate standards and 8.5 mg/g for well water were obtained until achieving the initial nitrate concentration. Experimental breakthrough curves fitted to Thomas model, which gave similar results for adsorption capacities. The adsorption capacity was checked with that obtained by a commercial resin, providing improved results. The method at large scale was compared with industrial traditional methods and green adsorbents.
Collapse
Affiliation(s)
- H R Robles-Jimarez
- MINTOTA Research Group, Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - L Sanjuan-Navarro
- MINTOTA Research Group, Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - N Jornet-Martínez
- MINTOTA Research Group, Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - C T Primaz
- Instituto de Tecnología de Materiales (ITM), Universitat Politècnica de València, 46022, Valencia, Spain
| | - R Teruel-Juanes
- Instituto de Tecnología de Materiales (ITM), Universitat Politècnica de València, 46022, Valencia, Spain
| | - C Molins-Legua
- MINTOTA Research Group, Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - A Ribes-Greus
- Instituto de Tecnología de Materiales (ITM), Universitat Politècnica de València, 46022, Valencia, Spain
| | - P Campíns-Falcó
- MINTOTA Research Group, Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| |
Collapse
|
6
|
Martínez-Aviñó A, Molins-Legua C, Campíns-Falcó P. Combining high performance thin layer chromatography with minispectrometer-fiber optic probe-coupled to smartphone for in place analysis: Lactose quantification in several matrices. J Chromatogr A 2021; 1661:462694. [PMID: 34879310 DOI: 10.1016/j.chroma.2021.462694] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 11/15/2021] [Accepted: 11/16/2021] [Indexed: 12/14/2022]
Abstract
An in place colorimetric method has been proposed for estimation of the quantity of lactose in several matrix (milk, water effluents and surfaces). Analyzing the amount of this carbohydrate it can be control the product, the cleanliness of the parts of the dairy companies and it can avoid contamination of milk products produced there. This method combines the use of HPTLC for sugars separation with novel analytical devices as minispectrophotometer with fiber optic coupled to a smartphone. In order to measure the lactose a colorimetric reaction has been used. Variable volumes of samples or stock solutions were deposited in nano-silica gel layer, a mobile phase of acetonitrile:water:acetic acid was used for carbohydrate separation and a solution of thymol (0.05 g Thymol in 95 mL of EtOH and 5 mL H2SO4) was used for revealed the carbohydrate spot. Finally, the reflectance of samples and stock solutions were measured. The achieved limits of detection were 0.03 mg mL-1 and 0.003 mg mL-1 for the working concentration range and the analysis at traces level respectively.
Collapse
Affiliation(s)
- Adria Martínez-Aviñó
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Valencia, Burjassot 46100, Spain
| | - Carmen Molins-Legua
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Valencia, Burjassot 46100, Spain.
| | - Pilar Campíns-Falcó
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Valencia, Burjassot 46100, Spain.
| |
Collapse
|
7
|
Martínez-Aviñó A, Hakobyan L, Ballester-Caudet A, Moliner-Martínez Y, Molins-Legua C, Campíns-Falcó P. NQS-Doped PDMS Solid Sensor: From Water Matrix to Urine Enzymatic Application. Biosensors (Basel) 2021; 11:bios11060186. [PMID: 34201174 PMCID: PMC8228043 DOI: 10.3390/bios11060186] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/03/2021] [Accepted: 06/04/2021] [Indexed: 11/16/2022]
Abstract
The development of in situ analytical devices has gained outstanding scientific interest. A solid sensing membrane composed of 1,2-naphthoquinone-4-sulfonate (NQS) derivatizing reagent embedded into a polymeric polydimethylsiloxane (PDMS) composite was proposed for in situ ammonium (NH4+) and urea (NH2CONH2) analysis in water and urine samples, respectively. Satisfactory strategies were also applied for urease-catalyzed hydrolysis of urea, either in solution or glass-supported urease immobilization. Using diffuse reflectance measurements combined with digital image processing of color intensity (RGB coordinates), qualitative and quantitative analyte detection was assessed after the colorimetric reaction took place inside the sensing membrane. A suitable linear relationship was found between the sensor response and analyte concentration, and the results were validated by a thymol-PDMS-based sensor based on the Berthelot reaction. The suggested sensing device offers advantages such as rapidity, versatility, portability, and employment of non-toxic reagents that facilitate in situ analysis in an energy-efficient manner.
Collapse
|
8
|
Bocanegra-Rodríguez S, Molins-Legua C, Campíns-Falcó P, Giroud F, Gross AJ, Cosnier S. Monofunctional pyrenes at carbon nanotube electrodes for direct electron transfer H 2O 2 reduction with HRP and HRP-bacterial nanocellulose. Biosens Bioelectron 2021; 187:113304. [PMID: 34020225 DOI: 10.1016/j.bios.2021.113304] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/29/2021] [Accepted: 05/02/2021] [Indexed: 12/16/2022]
Abstract
The non-covalent modification of carbon nanotube electrodes with pyrene derivatives is a versatile approach to enhance the electrical wiring of enzymes for biosensors and biofuel cells. We report here a comparative study of five pyrene derivatives adsorbed at multi-walled carbon nanotube electrodes to shed light on their ability to promote direct electron transfer with horseradish peroxidase (HRP) for H2O2 reduction. In all cases, pyrene-modified electrodes enhanced catalytic reduction compared to the unmodified electrodes. The pyrene N-hydroxysuccinimide (NHS) ester derivative provided access to the highest catalytic current of 1.4 mA cm-2 at 6 mmol L-1 H2O2, high onset potential of 0.61 V vs. Ag/AgCl, insensitivity to parasitic H2O2 oxidation, and a large linear dynamic range that benefits from insensitivity to HRP "suicide inactivation" at 4-6 mmol L-1 H2O2. Pyrene-aliphatic carboxylic acid groups offer better sensor sensitivity and higher catalytic currents at ≤ 1 mmol L-1 H2O2 concentrations. The butyric acid and NHS ester derivatives gave high analytical sensitivities of 5.63 A M-1 cm-2 and 2.96 A M-1 cm-2, respectively, over a wide range (0.25-4 mmol-1) compared to existing carbon-based HRP biosensor electrodes. A bacterial nanocellulose pyrene-NHS HRP bioelectrode was subsequently elaborated via "one-pot" and "layer-by-layer" strategies. The optimised bioelectrode exhibited slightly weaker voltage output, further enhanced catalytic currents, and a major enhancement in 1-week stability with 67% activity remaining compared to 39% at the equivalent electrode without nanocellulose, thus offering excellent prospects for biosensing and biofuel cell applications.
Collapse
Affiliation(s)
- Sara Bocanegra-Rodríguez
- Departamento de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Carmen Molins-Legua
- Departamento de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Pilar Campíns-Falcó
- Departamento de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Fabien Giroud
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS, 570 Rue de La Chimie, 38041, Grenoble, France
| | - Andrew J Gross
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS, 570 Rue de La Chimie, 38041, Grenoble, France.
| | - Serge Cosnier
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS, 570 Rue de La Chimie, 38041, Grenoble, France.
| |
Collapse
|
9
|
Martínez-Aviño A, Molins-Legua C, Pilar CF. Scaling the Analytical Information Given by Several Types of Colorimetric and Spectroscopic Instruments Including Smartphones: Rules for Their Use and Establishing Figures of Merit of Solid Chemosensors. Anal Chem 2021; 93:6043-6052. [PMID: 33819024 PMCID: PMC9177042 DOI: 10.1021/acs.analchem.0c03994] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
![]()
The
analytical information given by different types of instruments
was scaled in order to establish suitably the figures of merit of
a given methodology based on color measurements. Different lab and
portable instruments, including smartphones with and without a miniaturized
spectrophotometer accessory, have been tested. In order to obtain
broad information and using objective criteria, these instruments
have been compared from (1) the analytical point of view, considering
mainly the detection limit (limits of detection [LODs]), selectivity,
accuracy and intra- and interday precision, size, components, and
costs; and (2) the environmental point of view, based on their footprint
as kilograms of CO2. No significant differences in the
precision were obtained with RSD (%) values lower than 10% for all
of the instruments, but the achieved values of LOD, selectivity, accuracy,
and cost were different. Footprints of CO2 were better
for portable instrumentation, especially for smartphones. Three solid
chemosensors made of different materials (PDMS, paper, or nylon) have
been tested for the determination of ammonia and hydrogen sulfide
at different concentration levels (ppb levels). As a result of this
study,
some rules for selecting the instrument for obtaining the required
information have been established. Two apps have been developed for
quantitation by smartphones, one for working with RGB values and the
other for spectra obtained by the miniaturized spectrophotometer coupled
to a smartphone.
Collapse
Affiliation(s)
- Adria Martínez-Aviño
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Carmen Molins-Legua
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Campíns-Falcó Pilar
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| |
Collapse
|
10
|
Ballester-Caudet A, Hakobyan L, Moliner-Martinez Y, Molins-Legua C, Campíns-Falcó P. Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case. Talanta 2020; 223:121778. [PMID: 33298283 DOI: 10.1016/j.talanta.2020.121778] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 10/09/2020] [Accepted: 10/12/2020] [Indexed: 12/29/2022]
Abstract
A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registered and saved as images by a smartphone, which permit RGB measurements too. Flexible calibration was possible, adapting it to the sampling time, temperature and sampling volume needed for its application. Calibration linear slopes (mA vs ppmv) between 1.7 and 467 ppmv-1 were obtained for ammonia in function of the several studied conditions. Those slopes were between 48 and 91% higher than those achieved with sensors without ILs. The practical application of this sensing device was demonstrated for the analysis of meat packaging environments, being a potential cost-effective candidate for in situ meat freshness analysis. NQS provided selectivity in reference to other family compounds emitted from meat products, such as sulphides. After 10 days at 4 °C ammonia liberated by the assayed meat was 20 ± 4 μg/kg and 18 ± 3 μg/kg, quantified by using diffuse reflectance and %R measurements, respectively. Homogeneity of the ammonia atmosphere was tested by using two sensors placed in two different positions inside the packages.
Collapse
Affiliation(s)
- A Ballester-Caudet
- MINTOTA Research Group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100-Burjassot, Valencia, Spain
| | - L Hakobyan
- MINTOTA Research Group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100-Burjassot, Valencia, Spain
| | - Y Moliner-Martinez
- MINTOTA Research Group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100-Burjassot, Valencia, Spain.
| | - C Molins-Legua
- MINTOTA Research Group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100-Burjassot, Valencia, Spain
| | - P Campíns-Falcó
- MINTOTA Research Group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100-Burjassot, Valencia, Spain.
| |
Collapse
|
11
|
Bocanegra-Rodríguez S, Jornet-Martínez N, Molins-Legua C, Campíns-Falcó P. Portable solid sensor supported in nylon for silver ion determination: testing its liberation as biocide. Anal Bioanal Chem 2020; 412:4393-4402. [PMID: 32430541 DOI: 10.1007/s00216-020-02680-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 04/16/2020] [Accepted: 04/23/2020] [Indexed: 01/27/2023]
Abstract
This paper reports the fabrication and utility of a new solid sensor, which allows the quantitation of silver ions acting as catalyst at the low micromolar level. The optical sensor was prepared by incorporating both reagents, pyrogallol red (PGR) and 1,10-phenanthroline (Phen), in a nylon membrane. The effect of parameters in determining silver-catalyzed oxidation of PGR by persulfate in the presence of Phen as an activator was studied and optimized for achieving suitable sensitivity. Semiquantitative analysis can be performed by visual inspection of the color of the sensor by comparing it with standard responses and quantitative analysis can be carried out by its diffuse reflectance (DR) measurement or by a digital image-processing tool (GIMP) using a smartphone. The sensor exhibited a linear relationship toward Ag(I) concentrations ranging from 0.4 to 10 μM or 1-25 μM and limits of detection of 0.1 μM or 0.3 μM for incubation times of 50 and 30 min, respectively. The relative standard deviation achieved for several batches of sensors was around 2%. The analysis of water samples from tap and refrigerating circuits containing solid biocides, which leach silver ions, prove that this portable and sustainable sensor is successfully operational in real situations. Graphical abstract.
Collapse
Affiliation(s)
- Sara Bocanegra-Rodríguez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Neus Jornet-Martínez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain
| | - Carmen Molins-Legua
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| | - Pilar Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
12
|
Bocanegra-Rodríguez S, Jornet-Martínez N, Molins-Legua C, Campíns-Falcó P. New Reusable Solid Biosensor with Covalent Immobilization of the Horseradish Peroxidase Enzyme: In Situ Liberation Studies of Hydrogen Peroxide by Portable Chemiluminescent Determination. ACS Omega 2020; 5:2419-2427. [PMID: 32064402 PMCID: PMC7017489 DOI: 10.1021/acsomega.9b03958] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 01/08/2020] [Indexed: 05/27/2023]
Abstract
Herein, we reported a chemiluminescent biosensor based on the covalent immobilization of the horseradish peroxidase (HRP) enzyme on a polydimethylsiloxane (PDMS) support to quantify in situ hydrogen peroxide (H2O2). The chemiluminescent reaction based on the use of luminol as an oxidizable substrate, with HRP as the catalyst, has been used in order to quantify H2O2 as the oxidizing agent. The performance of the proposed biosensor has been demonstrated to determine H2O2 liberated by cells in a culture medium and for evaluating the delivery of H2O2 from denture cleaner tablets, as examples of application. For both analyses, the results indicated that the biosensor is cost-effective, sensitive, and selective with a detection limit of 0.02 μM and good linearity over the range 0.06-10 μM. Precision was also satisfactory (relative standard deviation, % RSD < 6). The strength of this biosensing system is the simplicity, portability, and reusability of the devices; it can be applied up to 60 times with 90% of its activity maintained.
Collapse
|
13
|
Jornet-Martínez N, Hakobyan L, Argente-García AI, Molins-Legua C, Campíns-Falcó P. Nylon-Supported Plasmonic Assay Based on the Aggregation of Silver Nanoparticles: In Situ Determination of Hydrogen Sulfide-like Compounds in Breath Samples as a Proof of Concept. ACS Sens 2019; 4:2164-2172. [PMID: 31364364 DOI: 10.1021/acssensors.9b01019] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
A procedure for supporting silver nanoparticles (AgNPs) on nylon is proposed. Besides, the membrane has been developed as a solid-phase colorimetric plasmonic sensor for volatile sulfide compounds (VSCs) like H2S, CH3SH, and (CH3)2S. AgNP behavior in the membrane has been studied by UV-vis diffuse reflectance spectrometry, Raman spectrometry, High-resolution transmission electron microscopy (HR-TEM), and Scanning electron microscopy (SEM). The sensor responded by changing its color from yellow in absence of VSCs to several orange/brown colors in the function of VSC concentration as occurs in solution; an increase in the hydrodynamic diameter, estimated by both asymmetrical flow field-flow fractionation (AF4) coupled on line to Dynamic light scattering (DLS) detector and batch DLS, is achieved when sulfide is added to the citrate-capped AgNPs. Diffuse reflectance spectrometry and processed digital images obtained with a smartphone have been used as measurements and several transformations for quantitation are proposed; a linear concentration range of hydrogen sulfide from 150 to 1000 ppbv and a detection limit (LOD) of 45 ppbv were achieved, measuring after 10 min of the sensor exposition to the hydrogen sulfide atmosphere (2 L) for humidity percentages between 50 and 96% and room temperature. Satisfactory results in terms of precision (<10%) and selectivity were obtained. The new sensor reported was stable, sensitive, inexpensive, disposable, safe, and user-friendly. Furthermore, it has successfully been applied to determine VSCs expressed as hydrogen sulfide in breath samples (2 L and 250 mL) as a proof of concept. The limit of detection can be improved by increasing the exposition time, if necessary.
Collapse
Affiliation(s)
- Neus Jornet-Martínez
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Lusine Hakobyan
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Ana Isabel Argente-García
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Carmen Molins-Legua
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Pilar Campíns-Falcó
- MINTOTA research group. Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| |
Collapse
|
14
|
Bocanegra-Rodríguez S, Jornet-Martínez N, Molins-Legua C, Campíns-Falcó P. Delivering Inorganic and Organic Reagents and Enzymes from Zein and Developing Optical Sensors. Anal Chem 2018; 90:8501-8508. [PMID: 29932323 DOI: 10.1021/acs.analchem.8b01338] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Nowadays, interest in using environmentally friendly materials is increasing in many fields. However, the rational design of sensors with biodegradable materials is a challenge. The main aim of this work is to show the possibility of using zein, a protein from corn, as a biodegradable and low-cost material for immobilizing, stabilizing, and delivering different kind of reagents for developing optical sensors. Enzymes, metallic salts, and aromatic and small organic compounds were tested. In addition, different techniques of immobilization, entrapment and adsorption, were used, and different formats, such as solid devices and also multiwell platforms, were proposed. The capacity of zein for immobilizing two reagents together, enzyme and substrate, into a multianalysis format was also shown. Two applications were developed as examples: a colorimetric assay based on a ferric hydroxamate reaction for ester drugs, which was applied in atropine determination in pills, and a fluorimetric enzymatic multiwell-plate biodevice applied in phosphate determination in human serum and urine. Zein demonstrated being not only a green alternative but also a versatile polymer for developing sensors from reagents with different natures in different formats and matrices, thereby resulting in different applications.
Collapse
Affiliation(s)
- Sara Bocanegra-Rodríguez
- MINTOTA research group, Departament de Química Analítica, Facultat de Química , Universitat de València , Dr. Moliner 50 , 46100 Burjassot , Valencia , Spain
| | - Neus Jornet-Martínez
- MINTOTA research group, Departament de Química Analítica, Facultat de Química , Universitat de València , Dr. Moliner 50 , 46100 Burjassot , Valencia , Spain
| | - Carmen Molins-Legua
- MINTOTA research group, Departament de Química Analítica, Facultat de Química , Universitat de València , Dr. Moliner 50 , 46100 Burjassot , Valencia , Spain
| | - Pilar Campíns-Falcó
- MINTOTA research group, Departament de Química Analítica, Facultat de Química , Universitat de València , Dr. Moliner 50 , 46100 Burjassot , Valencia , Spain
| |
Collapse
|
15
|
Serra-Mora P, Moliner-Martínez Y, Molins-Legua C, Herráez-Hernández R, Verdú-Andrés J, Campíns-Falcó P. Trends in Online Intube Solid Phase Microextraction. Comprehensive Analytical Chemistry 2017. [DOI: 10.1016/bs.coac.2017.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
16
|
Pla-Tolós J, Serra-Mora P, Hakobyan L, Molins-Legua C, Moliner-Martinez Y, Campins-Falcó P. A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footprint. Sci Total Environ 2016; 569-570:611-618. [PMID: 27376916 DOI: 10.1016/j.scitotenv.2016.06.181] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 06/21/2016] [Accepted: 06/22/2016] [Indexed: 06/06/2023]
Abstract
In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-10μg/L for irgarol-1051 and 0.7-10μg/L for diuron. The LODs were 0.015μg/L and 0.2μg/L for irgarol-1051 and diuron, respectively. Precision was also satisfactory (relative standard deviation, RSD<3.5%). The proposed methodology was applied to monitor water samples, taking into account the EQS standards for these compounds. The carbon footprint values for the proposed procedure consolidate the operational efficiency (analytical and environmental performance) of in-tube SPME-CapLC-DAD, in general, and in particular for determining irgarol-1051 and diuron in water samples.
Collapse
Affiliation(s)
- J Pla-Tolós
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain
| | - P Serra-Mora
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain
| | - L Hakobyan
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain
| | - C Molins-Legua
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain
| | - Y Moliner-Martinez
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain.
| | - P Campins-Falcó
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/ Doctor Moliner 50, E46100 Burjassot, Valencia, Spain.
| |
Collapse
|
17
|
Argente-García A, Muñoz-Ortuño M, Molins-Legua C, Moliner-Martínez Y, Campíns-Falcó P. A solid device based on doped hybrid composites for controlling the dosage of the biocide N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine in industrial formulations. Talanta 2016; 147:147-54. [DOI: 10.1016/j.talanta.2015.09.051] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 09/15/2015] [Accepted: 09/20/2015] [Indexed: 11/16/2022]
|
18
|
González-Fuenzalida RA, Moliner-Martínez Y, Molins-Legua C, Parada-Artigues V, Verdú-Andrés J, Campins-Falcó P. New Tools for Characterizing Metallic Nanoparticles: AgNPs, A Case Study. Anal Chem 2015; 88:1485-93. [DOI: 10.1021/acs.analchem.5b04751] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Rodrigo A. González-Fuenzalida
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - Yolanda Moliner-Martínez
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - Carmen Molins-Legua
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - Vanesa Parada-Artigues
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - Jorge Verdú-Andrés
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - Pilar Campins-Falcó
- MINTOTA Research Group. Departament
de Química Analítica, Facultat de Química, Universitat de Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| |
Collapse
|
19
|
Moliner-Martinez Y, Herráez-Hernández R, Verdú-Andrés J, Molins-Legua C, Campíns-Falcó P. Recent advances of in-tube solid-phase microextraction. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.020] [Citation(s) in RCA: 105] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
20
|
Muñoz-Ortuño M, Argente-García A, Moliner-Martínez Y, Molins-Legua C, Campíns-Falcó P. Polydimethylsiloxane composites containing 1,2-naphtoquinone 4-sulphonate as unique dispositive for estimation of casein in effluents from dairy industries. Anal Chim Acta 2015; 873:31-7. [DOI: 10.1016/j.aca.2015.02.057] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2014] [Revised: 02/13/2015] [Accepted: 02/21/2015] [Indexed: 10/23/2022]
|
21
|
Pla-Tolós J, Moliner-Martínez Y, Molins-Legua C, Herráez-Hernández R, Verdú-Andrés J, Campíns-Falcó P. Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine in water. J Chromatogr A 2015; 1388:17-23. [DOI: 10.1016/j.chroma.2015.02.024] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 02/06/2015] [Accepted: 02/10/2015] [Indexed: 11/26/2022]
|
22
|
Prieto-Blanco MC, Jornet-Martínez N, Moliner-Martínez Y, Molins-Legua C, Herráez-Hernández R, Verdú Andrés J, Campins-Falcó P. Development of a polydimethylsiloxane-thymol/nitroprusside composite based sensor involving thymol derivatization for ammonium monitoring in water samples. Sci Total Environ 2015; 503-504:105-112. [PMID: 25113949 DOI: 10.1016/j.scitotenv.2014.07.077] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 06/20/2014] [Accepted: 07/20/2014] [Indexed: 06/03/2023]
Abstract
This report describes a polydimethylsiloxane (PDMS)-thymol/nitroprusside delivery composite sensor for direct monitoring of ammonium in environmental water samples. The sensor is based on a PDMS support that contains the Berthelot's reaction reagents. To prepare the PDMS-thymol/nitroprusside composite discs, thymol and nitroprusside have been encapsulated in the PDMS matrix, forming a reagent release support which significantly simplifies the analytical measurements, since it avoids the need to prepare derivatizing reagents and sample handling is reduced to the sampling step. When, the PDMS-thymol/nitroprusside composite was introduced in water samples spontaneous release of the chromophore and catalyst was produced, and the derivatization reaction took place to form the indothymol blue. Thus, qualitative analysis of NH4(+) could be carried out by visual inspection, but also, it can be quantified by measuring the absorbance at 690 nm. These portable devices provided good sensitivity (LOD<0.4 mg L(-1)) and reproducibility (RSD <10%) for the rapid detection of ammonium. The PDMS-NH4(+) sensor has been successfully applied to determine ammonium in water samples and in the aqueous extracts of particulate matter PM10 samples. Moreover, the reliability of the method for qualitative analysis has been demonstrated. Finally, the advantages of the PDMS-NH4(+) sensor have been examined by comparing some analytical and complementary characteristics with the properties of well-established ammonium determination methods.
Collapse
Affiliation(s)
- M C Prieto-Blanco
- Grupo QANAP, Departamento de Química Analítica, Facultade de Ciencias, Universidade da Coruña, Campus de A Coruña, 15071 A Coruña, Spain
| | - N Jornet-Martínez
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Y Moliner-Martínez
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - C Molins-Legua
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - R Herráez-Hernández
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - J Verdú Andrés
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - P Campins-Falcó
- Departmento de Química Analítica Grupo MINTOTA, Facultad de Química, Universidad de Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| |
Collapse
|
23
|
Moliner-Martínez Y, Herraez-Hernandez R, Verdú-Andres J, Campíns-Falcó P, Garrido-Palanca C, Molins-Legua C, Seco A. Study of the influence of temperature and precipitations on the levels of BTEX in natural waters. J Hazard Mater 2013; 263 Pt 1:131-138. [PMID: 23978603 DOI: 10.1016/j.jhazmat.2013.07.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2013] [Revised: 07/02/2013] [Accepted: 07/17/2013] [Indexed: 06/02/2023]
Abstract
Assessment of seasonal changes in surface water quality is an important aspect for evaluating temporal variation of water due to natural or anthropogenic inputs of point and non-point sources. The objective of this paper was to investigate the influence of seasonal temperature fluctuations and precipitations on the levels of BTEX in natural waters. Principal component analysis (PCA) was used to evaluate the seasonal correlations of BTEX levels in water and to extract the parameters that are most important in assessing seasonal variations of water quality. This study was carried out as a part of VOCs monitoring program in natural water samples from Mediterranean coast. To carry out this project, a multiresidue analytical method was used. The method was based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography coupled to flame ionization detector (FID). The limits of detection LODs found for the tested analyte tested were in the 0.001-1 μg/L range. These values were adequate for the analysis of these compounds in water samples according to the regulated values. Water samples from different points of the Mediterranean coast were analyzed during a period of three years, and were taken four times per year. Most of the compounds were below the limit established by the legislation. The results obtained by a chemometric study indicated that temperature and precipitations can be related on the BTEX levels found in water. A regression model between temperature or precipitations and BTEX concentration was obtained, thus these models can be used as predictive model for detection any non-normal concentration level.
Collapse
Affiliation(s)
- Y Moliner-Martínez
- Departament de Química Analítica, Facultat de Química, Universitat de Valencia, C/ Dr. Moliner 50, E46100 Burjassot, Valencia, Spain
| | | | | | | | | | | | | |
Collapse
|
24
|
González-Fuenzalida RA, Moliner-Martínez Y, González-Béjar M, Molins-Legua C, Verdú-Andres J, Pérez-Prieto J, Campins-Falcó P. In situ colorimetric quantification of silver cations in the presence of silver nanoparticles. Anal Chem 2013; 85:10013-6. [PMID: 24131247 DOI: 10.1021/ac402822d] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Silver ions (Ag(+)) can be quantified in situ in the presence of AgNPs by using a colorimetric sensing probe (3,3',5,5'-tetramethylbenzidine). Interestingly, it also enables detection of the Ag(+) adsorbed on the AgNP surface. This is relevant to design new methods to make AgNPs while ensuring the total reduction of Ag(+).
Collapse
Affiliation(s)
- R A González-Fuenzalida
- Department of Analytical Chemistry, University of Valencia Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | | | | | | | | | | | | |
Collapse
|
25
|
Moliner-Martínez Y, Herráez-Hernández R, Molins-Legua C, Verdú-Andrés J, Avella-Oliver M, Campíns-Falcó P. More about sampling and estimation of mercaptans in air samples. Talanta 2013; 106:127-32. [PMID: 23598104 DOI: 10.1016/j.talanta.2012.12.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2012] [Revised: 11/29/2012] [Accepted: 12/03/2012] [Indexed: 11/19/2022]
Abstract
Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound on different support; a solution (Impinger) or sorbent (C₁₈ cartridges or glass fiber filter). The analytical properties of the different strategies have been obtained and compared. Procedures are recommended upon specific situations.
Collapse
Affiliation(s)
- Y Moliner-Martínez
- Departamento de Química Analítica, Facultad de Química, Universidad de Valencia, C/Dr. Moliner 50, - Burjassot, Valencia E46100, Spain
| | | | | | | | | | | |
Collapse
|
26
|
Moliner-Martínez Y, Molins-Legua C, Verdú-Andrés J, Herráez-Hernández R, Campíns-Falcó P. Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to capillary liquid chromatography. J Chromatogr A 2011; 1218:6256-62. [DOI: 10.1016/j.chroma.2011.07.026] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Accepted: 07/02/2011] [Indexed: 10/17/2022]
|
27
|
Moliner-Martinez Y, Herráez-Hernández R, Molins-Legua C, Campins-Falcó P. Improving analysis of apolar organic compounds by the use of a capillary titania-based column: Application to the direct determination of faecal sterols cholesterol and coprostanol in wastewater samples. J Chromatogr A 2010; 1217:4682-7. [DOI: 10.1016/j.chroma.2010.05.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2010] [Revised: 04/23/2010] [Accepted: 05/03/2010] [Indexed: 12/01/2022]
|
28
|
Campíns-Falcó P, Verdú-Andrés J, Sevillano-Cabeza A, Molins-Legua C, Herráez-Hernández R. New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aromatic hydrocarbons in bivalves. J Chromatogr A 2008; 1211:13-21. [DOI: 10.1016/j.chroma.2008.09.074] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2008] [Revised: 09/22/2008] [Accepted: 09/23/2008] [Indexed: 11/26/2022]
|
29
|
Campins-Falco P, Meseguer-Lloret S, Climent-Santamaria T, Molins-Legua C. A microscale Kjeldahl nitrogen determination for environmental waters. Talanta 2008; 75:1123-6. [DOI: 10.1016/j.talanta.2008.01.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2007] [Revised: 12/26/2007] [Accepted: 01/07/2008] [Indexed: 11/30/2022]
|
30
|
Meseguer-Lloret S, Molins-Legua C, Verdú-Andrés J, Campíns-Falcó P. Chemiluminescent Method for Detection of Eutrophication Sources by Estimation of Organic Amino Nitrogen and Ammonium in Water. Anal Chem 2006; 78:7504-10. [PMID: 17073419 DOI: 10.1021/ac0604437] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An automatic method has been developed for the estimation of organic amino nitrogen (CH2-NH) and ammonium in water samples. We propose a continuous flow system in which nitrogen compounds react with hypochlorite reagent to produce chloramines. Subsequently, the mixture is mixed with luminol, generating a chemiluminescence signal. The signal emission at 425 nm, registered as a function of time, decreases as nitrogen concentration increases, due to the decrease on hypochlorite concentration. A large number of nitrogen compounds have been assayed and their sensitivities compared, in milligrams per liter nitrogen. The ammonium calibration graph, expressed as N, can be used for most of the assayed compounds. The linear interval was 0.24-4 mg L(-1) N, with the detection limit 0.07 mg L(-1) N. The chemiluminescence method was applied to the analysis of several kinds of real water samples, natural, lake, irrigation ditch, fountain, residual, and seawater in order to detect possible sources of eutrophication. The accuracy (% relative error) and precision were satisfactory, with mean values of 5 +/- 4 and 3 +/- 2, respectively. This procedure has been used to estimate nitrogen content in samples before and after Kjeldahl treatment. In the same samples, the N found for the untreated samples provided a good estimation of the N Kjeldahl. Sixty samples per hour can be analyzed, and the procedure can also be used for in situ monitoring.
Collapse
Affiliation(s)
- S Meseguer-Lloret
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, C/Dr. Moliner 50, E46100- Burjassot, Valencia, Spain
| | | | | | | |
Collapse
|
31
|
Meseguer-Lloret S, Molins-Legua C, Campíns-Falcó P. Selective determination of ammonium in water based on HPLC and chemiluminescence detection. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2004.12.073] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
32
|
Campíns-Falcó P, Molins-Legua C, Sevillano-Cabeza A, Tortajada Genaro LA. o-Phthalaldelhyde-N-acetylcysteine polyamine derivatives: formation and stability in solution and in C18 supports. J Chromatogr B Biomed Sci Appl 2001; 759:285-97. [PMID: 11499482 DOI: 10.1016/s0378-4347(01)00236-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde-N-acetylcysteine (OPA-NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8 +/- 2 x 10(-2) min(-1) in solution versus 7.7 +/- 1.1 x 10(-4) min(-1) on the (C18) solid support. The results obtained showed that forming the derivative on the packing support (C18) gave the best results following this procedure: conditioning the cartridges with borate buffer (1 ml, 0.5 M, pH 8), retention of the analyte, addition of 0.8 ml of OPA-NAC reagent, 0.2 ml borate buffer 0.8 M (pH 8) and elution of the isoindol with 3 ml of MeOH-borate buffer (9:1). The different derivatization procedures have been used to study the stability of the reaction products OPA-NAC polyamines formed in urine matrix using spermine as model compound. Similar results were obtained for standard solutions and urine samples.
Collapse
Affiliation(s)
- P Campíns-Falcó
- Departamento de Química Analítica, Facultad de Química Universidad de València, Valencia, Spain.
| | | | | | | |
Collapse
|
33
|
Blasco-Gómez F, Bosch-Reig F, Campíns-Falcó P, Molins-Legua C, Herráez-Hernández R. H-point curve isolation method for coupled liquid chromatography and UV-visible spectrophotometry. Anal Chem 2000; 72:2559-65. [PMID: 10857635 DOI: 10.1021/ac990649q] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The H-point curve isolation method (HPCIM) for the detection of unknown interferences in chromatography is proposed. The method allows one to estimate the UV-vis spectra of interfering species in a sample as well as to test the purity of the chromatographic peaks. Besides the detection of the unknown interferences in a sample, this method allows one to calculate the concentration of an analyte in the presence of unknown compounds. To illustrate the reliability of the proposed method, samples of diuretics and amphetamines have been analyzed by normal- and reversed-phase high-performance chromatography.
Collapse
Affiliation(s)
- F Blasco-Gómez
- Departament de Química Analítica, Facultad de Química, Universidad de Valencia, Spain
| | | | | | | | | |
Collapse
|
34
|
Molins-Legua C, Campíns-Falcó P, Sevillano-Cabeza A, Pedrón-Pons M. Urine polyamines determination using dansyl chloride derivatization in solid-phase extraction cartridges and HPLC. Analyst 1999; 124:477-82. [PMID: 10605877 DOI: 10.1039/a808736i] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The derivatization of biogenic amines such as putrescine, cadaverine, spermidine and spermine with dansyl chloride in solid phase extraction cartridges is described. Different types of filling materials were tested in order to have the highest retention of the different analytes. The best results were obtained by using C18 cartridges. The optimal conditions were: amine solution buffered at pH 12, 2 mM dansyl chloride (acetone-bicarbonate solution 20 mM (pH 9-9.5), 2 + 3 v/v) as reagent concentration, room temperature and 30 min reaction time. The developed procedure was applied to the determination of these polyamines in urine samples from healthy controls and cancer patients using HPLC with 1,7-diaminoheptane as internal standard. The concentrations ranged from 0.5 to 5 micrograms mL-1 and the detection limits were 10 ng mL-1 for all polyamines. By concentrating the urine extracts, the detection limits were improved down to 2 ng mL-1. The accuracy and the precision of the method were tested. The proposed dansylation method is advantageous with respect to solution dansylation. It improves the total analysis time, avoids high temperatures that can affect the thermal stability of the derivatives and could make possible the automation of the procedure.
Collapse
Affiliation(s)
- C Molins-Legua
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, Spain
| | | | | | | |
Collapse
|
35
|
Molins-Legua C, Campíns-Falcó P, Sevillano-Cabeza A. Automated pre-column derivatization of amines in biological samples with dansyl chloride and with or without post-column chemiluminescence formation by using TCPO-H2O2. Analyst 1998; 123:2871-6. [PMID: 10435349 DOI: 10.1039/a805266b] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
On-line automation of two different liquid chromatographic procedures, a pre-column derivatization system and a pre- and post-column system, in order to generate chemiluminescence is reported. Dansyl chloride (Dns-Cl) was used as a pre-column reagent to form fluorophores and bis(2,4,6-trichlorophenyl) oxalate (TCPO) and hydrogen peroxide (H2O2) as a post-column reagent to generate chemiluminescence. This procedure is based on the employment of a primary column packed with C18 material inserted in a multi-dimensional assembly for sample clean-up and derivatization with Dns-Cl. The dansyl derivatives formed are transferred and separated in a LiChrospher 100 RP18 analytical column (125 x 4 mm id, 5 microns film thickness) using acetonitrile-imidazole buffer (pH 6.8) (70 + 30) as eluent. The separated derivatives were transferred to the detector for fluorescence detection or to the post-column system where the chemiluminescence response was generated by using TCPO-H2O2 and the products were detected by chemiluminescence. The procedure was optimised for amphetamine and related compounds. A comparison between the on-line pre-column and pre- and post-column systems was performed. The results show that the sensitivity of chemiluminescence detection can be higher than that of fluorescence detection. The recoveries obtained ranged from 98 +/- 8 up to 108 +/- 8% for amphetamine and methamphetamine, respectively. The accuracy and precision of these methods were evaluated.
Collapse
Affiliation(s)
- C Molins-Legua
- Departament de Química Analítica, Facultad de Química, Universitat de Valencia, Burjassot, Spain
| | | | | |
Collapse
|
36
|
Campíns-Falcó P, Sevillano-Cabeza A, Molins-Legua C. Amphetamine and Methamphetamine Determinations in Biological Samples by High Performance Liquid Chromatography. A Review. ACTA ACUST UNITED AC 1994. [DOI: 10.1080/10826079408013365] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|