1
|
Apple DJ, Borkenstein AF, Kleinmann G, Zuagg B, Auffarth G. The Role of the Soemmerring's Ring in the Pathogenesis of Post-Capsule Opacification and other Post-Surgical Opacifications. Klin Monbl Augenheilkd 2010. [DOI: 10.1055/s-0030-1249490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
2
|
Apple DJ, Borkenstein AFM, Kleinmann G, Zaugg B, Auffarth GU. The role of the Soemmerring's Ring in the pathogenesis of post-capsule opacification and other post-surgical opacifications. Klin Monbl Augenheilkd 2009. [DOI: 10.1055/s-0029-1213627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
3
|
Borkenstein AFM, Apple DJ, Kleinmann G, Zaugg B, Auffarth GU. New concepts on “no space – no cells“. New information derived from almost 57 years of observation of implanted Ridley lens. Klin Monbl Augenheilkd 2009. [DOI: 10.1055/s-0029-1213626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
4
|
Apple DJ. Kalzifizierung von Intraokularlinsen – Stand und neue Klassifikation. Klin Monbl Augenheilkd 2008. [DOI: 10.1055/s-2008-1057952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
5
|
Apple DJ. The final Farewell to Sir Harold Ridley. Klin Monbl Augenheilkd 2007. [DOI: 10.1055/s-2007-976191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
6
|
Apple DJ. A Comparison of IOL Biomaterials. Klin Monbl Augenheilkd 2007. [DOI: 10.1055/s-2007-976190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Syam P, Byrne P, Lewis G, Husain T, Kleinmann G, Mamalis N, Apple DJ, Rimmer T. Hydroview lens implant calcification: 186 exchanges at a district general hospital. Eye (Lond) 2006; 22:325-31. [PMID: 17057650 DOI: 10.1038/sj.eye.6702530] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
AIM This paper describes the experience at a district general hospital of coping with an abrupt onset of calcification of Hydroview intraocular lens (IOL) implants requiring exchange surgery mostly for symptoms of glare, even though the visual acuities were relatively good. METHODS In this retrospective study, the operative details of 174 consecutive lens exchanges by one surgeon were retrieved from the surgeon's notes. Of these, pre and post-operative details of 106 consecutive patients were obtained from the hospital notes. RESULTS Of the 174 lens exchanges, all were sutureless except one and 31 eyes (18%) had had previous capsulotomies. Of 143 eyes with intact posterior capsules, eight (5.6%) needed anterior vitrectomy. Lens replacements were in the bag in 136 (95%), in the sulcus in five (3.5%), and in the anterior chamber in two (1.5%). Of the 31 eyes with previous capsulotomies, 10 (32%) needed anterior vitrectomy. Lens replacements were in the bag in 22 (71%) and in the sulcus in the remaining nine cases (29%). Postoperatively the best-corrected visual acuity was improved in 53%, remained the same in 35%, and deteriorated in 12%. CONCLUSION The lens exchange procedure was mostly predictable with satisfactory visual results allowing preoperative counselling of risks to be similar to that for cataract surgery. The onset and resolution of the period of implantation of lenses requiring exchange has not been explained.
Collapse
Affiliation(s)
- P Syam
- Eye Department, Peterborough District Hospital, Peterborough, Cambs, UK
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Abstract
AIM To describe a new technique of suturing a tear in the anterior capsulorhexis. METHODS Continuous curvilinear capsulorhexis (CCC) with lens removal was done in five fresh cadaver eyes. The diameter of the CCC was measured with a calliper. Using the same calliper a tear of the CCC was created while opening the calliper's arms. The distance between the calliper's arms needed to tear the CCC was documented. Using 9-0 Ethilon 9011, CS 160-6 sutures in two eyes, 9-0 Prolene, D-8229, CTC-6L sutures in two eyes, and 10-0 Prolene, 9090, CTC-6 suture in one eye, the tears were sutured. A tear in the CCC was created again in the same way as the first tear. The distance between the calliper's arms needed to tear the CCC was documented again. RESULTS Suturing of the tear restored some of the strength/elasticity of the CCC. Better results were found while using the 9-0 Prolene, D-8229, CTC-6L sutures than with the two others sutures. CONCLUSIONS Suturing of a broken CCC can restore at least some of the strength/elasticity of the CCC. This can be important before intraocular lens (IOL) implantation for the safety of the implantation or after the implantation to ensure proper fixation of the IOL.
Collapse
Affiliation(s)
- G Kleinmann
- John A Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, 50 N. Medical Drive, Salt Lake City, UT 84132, USA.
| | | | | | | | | |
Collapse
|
9
|
Abstract
PURPOSE To report histologic findings in 14 AlphaCor artificial corneas implanted during clinical trials and subsequently explanted from human subjects following complications, so as to evaluate biointegration within the device skirt. METHODS Explants were fixed and sectioned in paraffin. Histologic findings related to the device skirt were compared with earlier histologic results from animal studies and correlated with clinical histories. RESULTS Two devices had been removed due to complications related to the optic alone, 11 following stromal melting overlying the biointegratable sponge skirt and 1 due to a retroprosthetic membrane. All devices demonstrated normal skirt porosity. Biointegration was similar to that found in animal studies but qualitatively appeared reduced in the affected areas in patients with overlying stromal melting prior to explantation. Patients with a longer history of melting prior to explantation demonstrated presence of inflammatory cells around the device. CONCLUSIONS Histologic findings of the AlphaCor skirt in humans are consistent with earlier animal studies. This study confirms that biointegration by host fibroblastic cells, with collagen deposition occurs after AlphaCor implantation in humans. In cases in which stromal melting had occurred, biointegration is seen to be reduced. On correlating preoperative clinical factors with biointegration observed histologically, preoperative vascularization appears not to be required for AlphaCor biointegration.
Collapse
Affiliation(s)
- C R Hicks
- Biomaterials Research Centre, Lions Eye Institute, University of Western Australia, Nedlands.
| | | | | | | | | |
Collapse
|
10
|
Kleinmann G, Marcovich AL, Apple DJ, Mamalis N. Linear deposits on the surfaces of intraocular lenses implanted through a hexagonal cartridge which mimic scratches/cracks on the lenses. Br J Ophthalmol 2005; 89:1474-7. [PMID: 16234456 PMCID: PMC1772926 DOI: 10.1136/bjo.2005.071738] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To describe unique linear deposits on the surface of posterior chamber intraocular lenses (IOLs) occurring after implantation through a hexagonal cartridge. METHODS Five ACR6D SE IOLs (Corneal Laboratories, Pringy, France) were injected/implanted through hexagonal cartridges. Two of these were injected into a petri dish and the remaining three were inserted into the evacuated capsular bag of cadaver eyes. In addition, three other ACR6D SE IOLs were injected into a petri dish through round cartridges. The latter served as controls. RESULTS All lenses that were injected/implanted through the hexagonal cartridges demonstrated linear deposits on the posterior surface of the IOL optic component. The IOLs that were injected through the round cartridges had no deposits. All the hexagonal cartridges showed signs of internal cracking. None of the round cartridges were cracked. CONCLUSION Implantation of at least one IOL model, the ACR6D SE IOL, through a hexagonal cartridge can result in linear deposits on the posterior optical surface of the IOL. The shape of the cartridge appears to be a significant factor in causing the depositions.
Collapse
Affiliation(s)
- G Kleinmann
- John A Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, 50 N Medical Drive, Salt Lake City, UT 84132, USA.
| | | | | | | |
Collapse
|
11
|
Apple DJ. Möglichkeiten der Nachstarprävention. Klin Monbl Augenheilkd 2005. [DOI: 10.1055/s-2005-863959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
12
|
Apple DJ. IOL 2004. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
13
|
Abstract
PURPOSE To report and compare clinical and pathological features of hydrophilic acrylic intraocular lenses (IOLs) of three major designs, explanted from patients who had visual disturbances caused by opacification of the lens optic. METHODS Eighty-seven hydrophilic acrylic IOLs (25 Hydroview, 54 SC60B-OUV, and 8 Aqua-Sense lenses) were explanted and sent to our center. Most patients became symptomatic during the second year after cataract surgery. A fine granularity was observed on the surface of the lens optic in the case of Hydroview. With the SC60B-OUV and Aqua-Sense lenses, the opacity resembled a nuclear cataract. Gross examination, light microscopy and staining with alizarin red and the von Kossa method (for calcium) were performed. Some lenses were submitted for scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). RESULTS Light microscopic and SEM analyses revealed the presence of irregular granular deposits on the external optical surfaces of Hydroview lenses. With the SC60B-OUV lenses, the opacity was caused by the presence of multiple fine, granular deposits within the lens optic, distributed in a line parallel to the anterior and posterior curvatures of the optic, with a clear zone just beneath its external surfaces. The Aqua-Sense lenses exhibited both patterns simultaneously. The deposits in all cases stained positive with alizarin red and von Kossa method. EDS also demonstrated the presence of calcium and phosphates within the deposits. CONCLUSION Differences in the water content of the hydrophilic acrylic materials used in the manufacture of these three lens designs may be responsible for the different patterns of calcium precipitation. Careful clinical follow up of patients implanted with these lenses is necessary to determine if this phenomenon is rare and sporadic or may be more widespread.
Collapse
Affiliation(s)
- A M Izak
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, 167 Ashley Avenue, Charleston, SC 29425-5536, USA
| | | | | | | |
Collapse
|
14
|
Vargas LG, Werner L, Pandey SK, Werner LP, Schmidbauer JM, Zuleta V, Escobar-Gómez M, Apple DJ. [Techniques for preparing postmortem human eyes to perform anterior segment intraocular surgery]. Arch Soc Esp Oftalmol 2003; 78:73-89. [PMID: 12647248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Abstract
We describe different methods to prepare postmortem human or animal eyes used at the Center for Research in Ocular Therapeutics and Biodevices at the Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USA. These techniques have been utilized for performing different surgical procedures (phacoemulsification, extracapsular cataract extraction, etc.), and for training of surgeons in-transition. Performing these techniques in the wet-laboratory contributed to improve surgical skills to perform the critical steps of the phacoemulsification surgery. Pathological evaluation of pseudophakic postmortem human eyes using the Miyake-Apple posterior view and histology was helpful to analyze postoperative complications of cataract surgery (anterior capsule opacification and posterior capsule opacification) secondary to postoperative proliferation of lens epithelial cells into the capsular bag. Modifications in the surgical techniques and/or lens design may be helpful to reduce these postoperative complications. Implantation of various aphakic and phakic intraocular lenses in postmortem human eyes as well as animal eyes was helpful to analyze the sizing and fitting of new lens designs within the eye.
Collapse
Affiliation(s)
- L G Vargas
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, USA.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Sandoval HP, Vargas LG, Holzer MP, Kasper TJ, Vroman DT, Apple DJ, Solomon KD. [Diffuse lamellar keratitis: prophylactic treatment with ketorolac tromethamine 0.5% in an animal model]. Arch Soc Esp Oftalmol 2002; 77:589-95. [PMID: 12410404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/19/2023]
Abstract
PURPOSE The objective of this study is to evaluate the use of a topical non-steroidal anti-inflammatory drug in the treatment of induced diffuse lamellar keratitis (DLK) in an animal model. MATERIALS AND METHODS A corneal flap was created in 40 eyes of 20 Dutch-belted rabbits using the ASC microkeratome. The interface was inoculated with either Pseudomonas Aeruginosa Lipopolysaccharide (LPS) endotoxin or Ultra Palmolive liquid dish washer. The rabbits were divided in two groups: Group I (n=20) treated with ketorolac tromethamine ophthalmic solution 0.5% 4 times a day and the group II (n=20) used as control. The rabbits were examined at the slit lamp at day 1, 3, 5 and 7 postoperatively. DLK was graded from I-IV. RESULTS At the end of the study 31 eyes were available for evaluation. 28 eyes (90%) developed DLK: 86% of the treated group and 94% of the control group during the follow-up. The treated group showed a lower rate of DLK as well as a lower severity. However, no statistically significant difference was found when comparing both groups (P>0.05). CONCLUSION Pseudomonas aeruginosa LPS endotoxin and Palmolive Ultra can induce DLK in rabbit eyes. The postoperative prophylactic treatment with a topical non-steroidal anti-inflammatory drug showed a tendency towards a lower DLK rate as well as the severity of the disease.
Collapse
Affiliation(s)
- H P Sandoval
- Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, SC 29425, USA.
| | | | | | | | | | | | | |
Collapse
|
16
|
Holzer MP, Solomon KD, Vargas LG, Sandoval HP, Kasper TJ, Vroman DT, Apple DJ. [Diffuse lamellar keratitis. Postoperative prophylactic treatment with corticosteroids in an experimental animal study]. Ophthalmologe 2002; 99:849-53. [PMID: 12430037 DOI: 10.1007/s00347-002-0638-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE The aim of this experimental ani-mal study was to induce diffuse lamellar keratitis (DLK), and investigate a prophylactic treatment with corticosteroids. MATERIALS AND METHODS A corneal flap was cut in 40 eyes from 20 Dutch-belted rabbits and the interface inoculated with either Pseudomonas aeruginosa lipopolysaccharide (LPS) endotoxin ( n=21) or Palmolive Ultra soap ( n=19). Half of the eyes were treated with topical corticosteroids and the other half remained untreated. Slitlamp examinations were performed 1, 3, 5 and 7 days postoperatively and DLK was graded from I-IV. RESULTS At the end of the study 33 eyes were available for evaluation and 94% of the non-treated eyes developed DLK. Out of those eyes treated with steroids 19% developed DLK during the 1 week follow-up period. This was statistically significantly lower ( P=0.018) when compared to the untreated group. CONCLUSION Pseudomonas aeruginosa LPS endotoxin as well as Palmolive((R)) Ultra caused a very high rate of DLK in rabbit eyes. The postoperative prophylactic treatment with corticosteroids showed a statistically significant lower DLK rate in this rabbit eye model.
Collapse
Affiliation(s)
- M P Holzer
- Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USA.
| | | | | | | | | | | | | |
Collapse
|
17
|
Auffarth GU, Schmidbauer J, Becker KA, Rabsilber TM, Apple DJ. [Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant]. Ophthalmologe 2002; 99:811-4. [PMID: 12430031 DOI: 10.1007/s00347-002-0717-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND The potentially accommodative intraocular lens (IOL) is a new development in IOL design METHODS We evaluated the new Humanoptics 1CU accommodative IOL in a laboratory study with human post mortem autopsy eyes. Using the Miyake-Apple posterior view video technique, the movement pattern of the IOL was tested and observed from the posterior perspective. RESULTS. A circular bend at the level of the ciliary body applied slight circular force onto the sclera allowing the relaxation of the zonules. The shift of focus was demonstrated by using a reading target. In addition, viscoelastic was injected into the vitreous resulting in the same anterior movement of the IOL optic. CONCLUSIONS The 1CU Humanoptics accommodative IOL showed potential accommodative behaviour in the laboratory. The accommodative (respectively pseudoaccommodative) effect was based on the anterior shift principle with anterior movement of the IOL-optic in the state of relaxing zonules. Whether this reflects the clinical situation, especially to this extent, must be further evaluated.
Collapse
Affiliation(s)
- G U Auffarth
- Universitäts-Augenklinik mit Poliklinik, Heidelberg, Germany.
| | | | | | | | | |
Collapse
|
18
|
Schmidbauer JM, Golescu A, Vargas LG, Escobar-Gomez M, Apple DJ. [Peripapillary tumor in autopsy eyes. Myelin artefact]. Ophthalmologe 2002; 99:732-3. [PMID: 12463203 DOI: 10.1007/s00347-002-0609-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
19
|
Abstract
Intraocular lens (IOL) implantation has no doubt been one of the most satisfying advances of medicine. Millions of individuals with visual disability or frank blindness from cataracts had and continue to have benefit from this procedure. It has been reported by ophthalmologists that the modern cataract-intraocular lens (IOL) surgery is safe and complication-free most of the time. This makes the watchword for any cataract surgeon to be 'implantation,' 'implantation,' 'implantation.' In the mid-1980s, as IOLs were evolving rapidly, the watchword of the implant surgeon was 'fixation,' 'fixation,' 'fixation.' Most techniques, lenses and surgical adjuncts now allow us to achieve the basic requirement for successful IOL implantation, namely long-term stable IOL fixation in the capsular bag. However despite this advancement some items 'slipped through cracks.' In this article, we would like to alert the reader to a new watchword, namely 'opacification,' 'opacification,' 'opacification.' Here we will be talking about the good, the bad, and the ugly. Examples of the 'good' include the recent successes now being achieved in reducing the incidence of posterior capsule opacification. Examples of the 'bad' include various proliferations of anterior capsule cells, problems caused by silicone oil adherence to IOLs and problems with piggyback IOLs. The 'ugly' include the sometimes striking and often visually disabling opacifications occurring on and within IOL optics, both on some modern foldable IOLs as well as a poly(methyl methacrylate) (PMMA) optic degradation occurring with some models a decade or more after implantation.
Collapse
Affiliation(s)
- R H Trivedi
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, SC 29425-5536, USA
| | | | | | | | | |
Collapse
|
20
|
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices, Medical University of South Carolina, USA
| | | | | | | | | |
Collapse
|
21
|
|
22
|
Arthur S, Steed LL, Apple DJ, Peng Q, Howard G, Escobar-Gomez M. Scedosporium prolificans keratouveitis in association with a contact lens retained intraocularly over a long term. J Clin Microbiol 2001; 39:4579-82. [PMID: 11724890 PMCID: PMC88594 DOI: 10.1128/jcm.39.12.4579-4582.2001] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Scedosporium prolificans is a soil saprophyte that is associated with a large variety of infectious processes and with respiratory colonization in immunocompetent and immunocompromised patients. We report the first described case of S. prolificans keratouveitis associated with the intraocular long-term retention of a contact lens in a 76-year-old female patient.
Collapse
Affiliation(s)
- S Arthur
- Center for Research on Ocular Therapeutics and Biodevices, Medical University of South Carolina, Charleston 29425, USA
| | | | | | | | | | | |
Collapse
|
23
|
Schmidbauer JM, Pandey SK, Apple DJ, Auffarth GU, Ma L, Werner L, Escobar-Gomez M, Vargas LG. [Morphological autopsy findings in human eyes implanted with Ridley intraocular lenses]. Ophthalmologe 2001; 98:1036-43. [PMID: 11729734 DOI: 10.1007/s003470170022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Sir Harold Ridley's first cataract extraction with implantation of an intraocular lens (IOL) marked the beginning of a major change in the practice of ophthalmology. MATERIAL AND METHODS Two human autopsy globes implanted with original Ridley IOLs were grossly examined from behind with the Miyake-Apple photographic technique. The anterior segments were evaluated histologically. One Ridley IOL was examined by scanning electron microscopy. RESULTS Both IOLs maintained a clear visual axis and had been placed in the capsular sac. The right lens was decentered inferiorly, the left IOL was well centered. The posterior capsule showed only minimal capsular opacification. Scanning electron microscopy (SEM) of the explanted IOL showed a smooth, well polished surface. CONCLUSIONS In this patient Ridley IOLs maintained an ideal visual rehabilitation of 20/20 in both eyes, 22 and 18 years postoperatively. One surprising finding was the presence of a square, truncated optic edge geometry, very similar to that seen in some modern foldable IOLs. In our opinion the absence of posterior capsule opacification of the Ridley IOL may have partially been a result of this nearly sharp optic edge, that we confirmed by SEM. Even 22 years after implantation the Ridley IOL showed a high finish quality. Many of Sir Harold Ridley's early concepts like the IOL placement in the posterior chamber and endocapsular implantation are now the standard of modern cataract surgery.
Collapse
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices, Storm Eye Institute, Medical University of South Carolina, USA
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Abstract
On may 25th 2001 Sir Harold Ridley died at age 94. With him Ophthalmology lost one of the greatest and most influential Ophthalmologist of the post-war time. He is the founder of modern cataract surgery implanting the first intraocular lens after extracapsular cataract extraction 50 years ago. He pioneered in what became one of the most important success stories in Ophthalmology. His vision and concepts managed to succeed against strong opposition worldwide. Modern cataract surgery and modern refractive IOL surgery would not been possible without his contribution. Sir Harold Ridley reached a high age and was therefore able to see his visions become reality and finally receive all honours and awards he deserved over the past 15 years, including the knighthood by Queen Elisabeth II in the year 2000. The following article gives a summary of his biography and contributions to Ophthalmology.
Collapse
Affiliation(s)
- G U Auffarth
- Universitäts-Augenklinik, Ruprecht Karls Universität Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg.
| | | | | |
Collapse
|
25
|
Escobar-Gómez M, Apple DJ, Vargas LG. [Tribute to Sir Nicholas Harold Ridley: inventor of intraocular lenses]. Arch Soc Esp Oftalmol 2001; 76:687-8. [PMID: 11715110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Affiliation(s)
- M Escobar-Gómez
- Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, USA
| | | | | |
Collapse
|
26
|
Abstract
Even though cataract surgery has been practiced for over 2000 years, modern cataract surgery started just some 50 years ago. with the first IOL implantation by Sir Harold Ridley. The development of intraocular lenses was accompanied by great successes and disasters. With the fast development of cataract surgical techniques over the past 15 years (ECCE, Phacoemulsification, Capsulorhexis) a successful marriage between IOL-developments and surgery was established. Indication profiles for cataract surgery and IOL implantation extended to more and more patient groups. At this time classical cataract surgery is further developing into refractive intraocular lens surgery to correct higher ametropia in clear lens or phakic eyes. This development was only possible because of the improvements of surgical techniques and implants in classical cataract surgery.
Collapse
Affiliation(s)
- G U Auffarth
- Universitäts-Augenklinik, Ruprecht Karls Universität Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg.
| | | |
Collapse
|
27
|
Schmidbauer JM, Apple DJ, Auffarth GU, Peng Q, Pandey SK, Werner L, Escobar-Gomez M, Vargas LG. [Complication profiles of posterior chamber intraocular lenses IOL). An analysis of 586 foldable and 2077 rigid explanted intraocular lenses]. Ophthalmologe 2001; 98:1029-35. [PMID: 11729733 DOI: 10.1007/s003470170021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Foldable intraocular lenses (IOL) have become increasingly preferred choice for IOL implantation after cataract removal. However, both foldable as well as rigid IOLs are not yet complication-free and may need explanation. MATERIAL AND METHODS A total of 2663 explanted posterior chamber IOLs (PCIOLs) were accessioned at the Center for Research on Ocular Therapeutics and Biodevices between January 1988 and September 2000. The lenses were examined grossly using a Leitz/Wild M-8-Zoom stereomicroscope. The clinical reasons for explanation were documented for foldable as well as for rigid lenses. RESULTS Of a total of 2663 explanted PCIOLs, 586 were foldable lenses and 2077 were rigid PMMA lenses The most frequent reason for explantation of all 2663 IOLs studied was decentration/dislocation. Optic and haptic damage and posterior capsule rupture were significantly more often a reason for explantation in several foldable designs compared to rigid PCIOLs. Whereas rigid designs lead more often to corneal decompensation. The percentage of explanted IOLs because of inflammatory reactions decreased significantly from 1994 to 2000. CONCLUSIONS The complication profiles of rigid and foldable IOLs revealed some apparent differences due to the nature of the IOL biomaterials and designs. IOL optic/haptic damage was a common complication for foldable IOLs, whereas it was only discovered in single digits for rigid PMMA IOLs. The possible explanation for this is, that the soft and flexible biomaterials, from which all the foldable IOLs were manufactured, are easier to be damaged during folding, unfolding and insertion procedure. In our opinion this relative disadvantage of foldable IOLs is by far outweighed by the numerous advantages of the small incision cataract surgery. The decreasing inflammatory reactions can be explained by advances in surgical techniques, especially the secure in-the-bag fixation of IOLs.
Collapse
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices, Medical University of South Carolina, USA
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Vargas LG, Peng Q, Escobar-Gomez M, Schmidbauer JM, Apple DJ. Overview of modern foldable intraocular lenses and clinically relevant anatomy and histology of the crystalline lens. Int Ophthalmol Clin 2001; 41:1-15. [PMID: 11481534 DOI: 10.1097/00004397-200107000-00003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- L G Vargas
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | |
Collapse
|
29
|
Affiliation(s)
- T A Macky
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
30
|
Affiliation(s)
- S N Arthur
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | |
Collapse
|
31
|
Affiliation(s)
- L Werner
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
32
|
Escobar-Gomez M, Arthur SN, Apple DJ, Vargas LG, Pandey SK, Schmidbauer J. Evolution of surgical techniques and intraocular lens designs for the developing world. Int Ophthalmol Clin 2001; 41:197-210. [PMID: 11481547 DOI: 10.1097/00004397-200107000-00014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- M Escobar-Gomez
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
33
|
Peng Q, Apple DJ, Arthur SN, Merritt JH, Escobar-Gomez M, Hoddinott DS. Snowflake opacification of poly(methyl methacrylate) intraocular lens optic biomaterial: a newly described syndrome. Int Ophthalmol Clin 2001; 41:91-107. [PMID: 11481542 DOI: 10.1097/00004397-200107000-00009] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Q Peng
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
34
|
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | | | |
Collapse
|
35
|
Pandey SK, Wilson ME, Trivedi RH, Izak AM, Macky TA, Werner L, Apple DJ. Pediatric cataract surgery and intraocular lens implantation: current techniques, complications, and management. Int Ophthalmol Clin 2001; 41:175-96. [PMID: 11481546 DOI: 10.1097/00004397-200107000-00013] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- S K Pandey
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | | | |
Collapse
|
36
|
Affiliation(s)
- R H Trivedi
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
37
|
Arthur SN, Peng Q, Apple DJ, Escobar-Gomez M, Bianchi R, Pandey SK, Werner L. Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses. J Cataract Refract Surg 2001; 27:1662-9. [PMID: 11687368 DOI: 10.1016/s0886-3350(01)00891-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. RESULTS The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. CONCLUSIONS Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.
Collapse
Affiliation(s)
- S N Arthur
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA
| | | | | | | | | | | | | |
Collapse
|
38
|
Pandey SK, Werner L, Apple DJ, Agarwal A, Agarwal A, Agarwal S. No-anesthesia clear corneal phacoemulsification versus topical and topical plus intracameral anesthesia. Randomized clinical trial. J Cataract Refract Surg 2001; 27:1643-50. [PMID: 11687365 DOI: 10.1016/s0886-3350(01)00793-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE To compare the intraoperative pain scores during clear corneal phacoemulsification under no anesthesia, topical anesthesia, and topical plus intracameral anesthesia. SETTING Dr. Agarwal's Eye Hospital and Eye Research Center, Chennai, India. METHODS Seventy-five patients were randomized to have phacoemulsification under no anesthesia, topical anesthesia, or topical plus intracameral anesthesia. Uncooperative or illiterate patients and those with hard cataract, a shallow anterior chamber, or small pupils were excluded. A protocol was established for supplemental anesthesia in case of breakthrough pain during the surgery. Each patient was asked to grade the overall severity of intraoperative pain immediately after surgery on a 10-point visual analog scale. Also evaluated were the general discomfort during surgery, discomfort from the microscope lights, surgeon stress during surgery, and total surgical time. Comparison among the 3 groups was performed using an analysis of variance. RESULTS No supplemental anesthesia was required in any group. No significant difference was noted in the mean scores of the subjective sensation of pain with or without topical anesthesia (P =.610). The mean scores of patient discomfort from the microscope lights and surgical time were also statistically insignificant. Patient discomfort and surgeon stress during surgery were significantly greater in the no-anesthesia group than in the topical and topical plus intracameral groups (P =.0235 and P = 0.0206, respectively). CONCLUSION No-anesthesia clear corneal phacoemulsification was performed by a highly experienced, skilled surgeon without causing an unacceptable level of pain. However, this technique is not suitable for every cataract surgeon or patient.
Collapse
Affiliation(s)
- S K Pandey
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.
| | | | | | | | | | | |
Collapse
|
39
|
Schmidbauer JM, Vargas LG, Apple DJ, Auffarth GU, Peng Q, Arthur SN, Escobar-Gomez M. [Millenniums update on posterior capsule opacification (PCO) scores, centration, biocompatibility and fixation of foldable intraocular lenses (IOL) - an analysis of 1,221 pseudophakic post mortem globes]. Klin Monbl Augenheilkd 2001; 218:649-57. [PMID: 11706380 DOI: 10.1055/s-2001-18386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States. MATERIAL AND METHODS We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique. RESULTS The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySoftrade mark IOL displays the the lowest (best) biocompatibility score. CONCLUSIONS Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing.
Collapse
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425, South Carolina, USA
| | | | | | | | | | | | | |
Collapse
|
40
|
Apple DJ, Schmidbauer JM. [Sir Nicholas Harold Lloyd Ridley: pioneer of intraocular lens]. Klin Monbl Augenheilkd 2001; 218:583-5. [PMID: 11590464 DOI: 10.1055/s-2001-17634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
41
|
Schmidbauer JM, Werner L, Apple DJ, Pandey SK, Izak AM, Trivedi RH, Macky TA, Auffarth GU, Peng Q, Arthur SN, Escobar-Gomez M, Ma L, Vargas LG. [Postoperative opacification of posterior chamber intraocular lenses - a review]. Klin Monbl Augenheilkd 2001; 218:586-94. [PMID: 11590465 DOI: 10.1055/s-2001-17635] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Postoperative opacification of intraocular lenses (IOLs) is a very unpleasant complication for the ophthalmic surgeon and the patient. We report on our experiences with opacification of different foldable IOL designs and rigid poly (methyl methacrylate) (PMMA) posterior chamber lenses.1. Snowflake degeneration of PMMA IOLs: This condition is an unanticipated and surprising late postoperative finding 8 to 15 years after implantation. In our opinion, this complication is probably not related to the PMMA biomaterial itself, but rather it appears to represent a manufacturing problem that has affected a selected, albeit large number of lenses manufactured in the 1980s-mid 1990s.2. Degeneration of UV absorber material and calcium deposits within the optic of hydrophilic IOLs: Two years postoperatively degenerations of UV absorber material and calcium deposits within the optic of single piece hydrophilic acrylic lenses SC60B-OUV manufactured by MDR (Medical developmental research Inc. Clearwater FL, USA) can occur. Although the precise mechanism is not fully known, it was assumed that these opacifications are due to premature aging of the UV blocking agent incorporated in the lens biomaterial and calcification.3. Calcification on the surface of the Bausch & Lomb Hydroviewtrade mark IOLs: Twelve to 15 months postoperatively granular surface calcifications in Hydroviewtrade mark IOLs occured. The mechanism is not fully understood. According to Bausch and Lomb studies, part of the components of the packaging contained silicone, which may have come off the packaging onto the lens optic, where it then appears to be a catalyst for calcium precipitation. The manufacturer has correlated a change in packaging with the appearance of the opacification. The manufacturer now believes that this problem has been solved. However, final verification will require a careful 1 - 2 years clinical study.4. Glistenings in the hydrophobic acrylic AcrySoftrade mark IOLs: The time frame of glistenings in the AcrySoftrade mark IOLs is highly variable. It has been suggested that the occurrence of glistenings may be related to variations in the temperature of the lens just prior to and or during insertion into the eye. Formation of vacuoles may occur within the submersed acrylic polymer when there is a transient increase and then decrease in temperature during the surgical procedure. "Glistenings" may then subsequently form by ingress of anterior chamber fluid. Contrast sensitivity can been decreased in some patients, but clinically significant decrease of visual acuity has been rare.
Collapse
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices; Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, 167 Ashley Avenue, Charleston SC 29425-2236, South Carolina, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Werner L, Apple DJ, Kaskaloglu M, Pandey SK. Dense opacification of the optical component of a hydrophilic acrylic intraocular lens: a clinicopathological analysis of 9 explanted lenses. J Cataract Refract Surg 2001; 27:1485-92. [PMID: 11566535 DOI: 10.1016/s0886-3350(01)00841-0] [Citation(s) in RCA: 133] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To report clinical, pathological, histochemical, ultrastructural, and spectrographic analyses of explanted hydrophilic acrylic intraocular lenses (IOLs) obtained from patients who had visual disturbances caused by postoperative opacification of the lens optic. SETTING Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA, and Ege University, Alsancak Izmir, Turkey. METHODS Nine hydrophilic IOLs (SC60B-OUV, MDR Inc.) were explanted from 9 patients with decreased visual acuity. Most patients became symptomatic approximately 24 months after uneventful phacoemulsification and IOL implantation. Opacification was noted and appeared clinically to be associated with a fine granularity within the substance of the IOL optic. The IOLs were forwarded to the center and examined by gross and light microscopy. Full-thickness cut sections of the optics were stained with 1% alizarin red and the von Kossa method (special stains for calcium). Some were submitted for scanning electron microscopy and energy dispersive x-ray spectroscopy. RESULTS Microscopic analyses revealed multiple fine, granular deposits of variable sizes within the lens optics, usually distributed in a line parallel to the anterior and posterior curvatures of the optic, with a clear zone just beneath the optic surface. The deposits stained positive with alizarin red and the von Kossa method. Energy dispersive x-ray spectroscopy of the internal substance of sectioned IOLs demonstrated the presence of calcium within the deposits. CONCLUSION This is the first clinicopathological report of optic opacification occurring with this hydrophilic acrylic IOL model. Studies of similar cases with this lens should be done to determine the incidence and possible mechanisms of the phenomenon.
Collapse
Affiliation(s)
- L Werner
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.
| | | | | | | |
Collapse
|
43
|
Werner L, Pandey SK, Apple DJ, Escobar-Gomez M, McLendon L, Macky TA. Anterior capsule opacification: correlation of pathologic findings with clinical sequelae. Ophthalmology 2001; 108:1675-81. [PMID: 11535472 DOI: 10.1016/s0161-6420(01)00674-1] [Citation(s) in RCA: 112] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To evaluate the degree of anterior capsule opacification (ACO) in human eyes obtained postmortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs and compare the findings with clinical sequelae of capsular shrinkage. DESIGN Comparative autopsy tissue study with clinicopathologic correlations. MATERIALS Three hundred formalin-fixed human eyes containing the following PC-IOL styles were analyzed: (1) one-piece polymethyl methacrylate (PMMA) optic-PMMA haptic (n = 50), one-piece silicone-plate IOL, with large (2) or small (3) fixation holes (n = 35), (4) three-piece PMMA optic-Prolene haptic (n = 50), (5) three-piece acrylic optic-PMMA haptic (n = 55), three-piece silicone optic with PMMA (6) or polyimide (7) haptics (n = 30), and (8) three-piece silicone optic-Prolene haptic (n = 80) lenses. TESTING The eyes were sectioned in the equatorial plane for gross examination of the capsular bag from a posterior view. The cornea and iris were then excised for evaluation from an anterior view. MAIN OUTCOME MEASURES ACO was scored in each eye from 0 to IV, according to the degree/area of capsule opacification. Capsulorrhexis size and IOL decentration were measured with calipers. RESULTS The overall differences among the IOL groups regarding the three parameters were significant (ACO score: P < 0.001; capsulorrhexis diameter: P = 0.036; IOL decentration: P = 0.012). Mean ACO scores were highest with the large- and small-hole one-piece silicone-plate lenses (2.543 +/- 0.950) and lowest with the three-piece acrylic optic-PMMA haptic lenses (0.600 +/- 0.710). Of 10 cases of capsulorrhexis phimosis observed in the study, 7 cases were associated with three-piece silicone optic-Prolene haptic lenses, which also presented the highest mean decentration (0.375 +/- 0.601 mm). CONCLUSIONS Our results confirm previous histopathologic observations that the rate of ACO is the lowest with acrylic lenses and higher with plate-haptic silicone IOLs. Nevertheless, clinical sequelae of capsular shrinkage are also very important with three-piece silicone optic-Prolene haptic designs. Thus, IOL material and design are significant factors in the development of ACO, but they ultimately also influence the clinical presentation of capsular shrinkage.
Collapse
Affiliation(s)
- L Werner
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA
| | | | | | | | | | | |
Collapse
|
44
|
Schmidbauer JM, Vargas LG, Apple DJ, Peng Q, Arthur SN, Escobar-Gomez M, Izak A. [Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem]. Klin Monbl Augenheilkd 2001; 218:523-7. [PMID: 11573152 DOI: 10.1055/s-2001-17133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
BACKGROUND The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape. MATERIALS AND METHODS Human eyes obtained post-mortem implanted with 3-piece silicone optic - PMMA haptic (SI 40 NB) and 3-piece silicone optic - Prolene haptic (SI 30 NB) designs IOLs, accessioned between January 1993 and December 2000 were evaluated by gross examination from behind under an operating microscope using the Miyake-Apple posterior photographic technique. The area and intensity of Soemmerring's ring and type of fixation was studied in 457 eyes. The mean diameter of the CCC and relation of the CCC edge to the optic rim were analyzed in 221 eyes. RESULTS 1) The amount of Soemmerring's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy in both the SI 40 NB and SI 30 NB design than in the IOLs without capsulotomies. 2) The percentage of not in-the-bag fixated IOLs in both the SI 40 NB and SI 30 NB design was larger in the "Nd:YAG groups", without being statistically significant. 3) The "Nd:YAG groups" showed a significant higher amount of non overlapping clock hours of the CCC edge in relation to the optic rim. CONCLUSION 1) The data confirm the clinical assumption that the incidence of PCO is correlated with the cortical clean up. 2) Our findings also support the clinical assumption, that poor IOL fixation increases the risk of PCO. 3) This study also verifies the relation of the CCC to PCO, namely a relatively small CCC covering the entire optic rim is best to reduce the Nd:YAG laser rate.
Collapse
Affiliation(s)
- J M Schmidbauer
- Center for Research on Ocular Therapeutic and Biodevices; Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425, South Carolina, USA.
| | | | | | | | | | | | | |
Collapse
|
45
|
Ram J, Pandey SK, Apple DJ, Werner L, Brar GS, Singh R, Chaudhary KP, Gupta A. Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification. J Cataract Refract Surg 2001; 27:1039-46. [PMID: 11489573 DOI: 10.1016/s0886-3350(00)00841-5] [Citation(s) in RCA: 67] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE To compare the incidence of posterior capsule opacification (PCO) after extracapsular cataract extraction (ECCE) and phacoemulsification and to evaluate the role of posterior chamber intraocular lens (PC IOL) haptic fixation and biomaterial/design in reducing the incidence. SETTING Postgraduate Institute of Medical Education and Research, Chandigarh, India; Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS This study comprised 278 eyes of 263 patients having ECCE and 318 eyes of 297 patients having phacoemulsification with PC IOL implantation. Posterior capsule opacification leading to a decrease in Snellen visual acuity of 2 or more lines was considered visually significant. The presence of PCO and IOL haptic fixation were evaluated postoperatively using slitlamp biomicroscopy. Haptic position was noted as in-the-bag (B-B), 1 haptic in the bag and 1 in the sulcus (bag-sulcus [B-S]), or both haptics out of the bag (sulcus-sulcus [S-S]). In addition, the rate of visually significant PCO was compared among 3 IOL biomaterials: poly(methyl methacrylate), silicone, and hydrophobic acrylic. RESULTS Visually significant PCO occurred in 42.45% of eyes having ECCE and 19.18% of eyes having phacoemulsification (P <.001, chi-square test) after a mean follow-up of 2.4 years +/- 0.7 (SD). In both groups, visually significant PCO was significantly less in eyes with B-B fixation than in those with B-S or S-S fixation (P <.001). The rate of visually significant PCO in all eyes in the phacoemulsification group with B-B fixation was low (11.90%) and was significantly lower in eyes with a hydrophobic acrylic IOL (2.22%; P <.05, chi-square test). CONCLUSIONS In-the-bag PC IOL fixation is required to consistently reduce the incidence of PCO. Thorough removal of lens substance, including hydrodissection-assisted cortical cleanup, and in-the-bag PC IOL fixation seem to be the most important factors in reducing PCO, regardless of surgical procedure or IOL type used. Intraocular lens biomaterial and design also help prevent PCO.
Collapse
Affiliation(s)
- J Ram
- Department of Ophthalmology, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India.
| | | | | | | | | | | | | | | |
Collapse
|
46
|
|
47
|
|
48
|
Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M, Ram J, Auffarth GU. Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 2001; 108:505-18. [PMID: 11237905 DOI: 10.1016/s0161-6420(00)00589-3] [Citation(s) in RCA: 209] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVE (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. DESIGN Comparative autopsy tissue analysis. PARTICIPANTS A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. METHODS Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. MAIN OUTCOME MEASURES The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. RESULTS Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable IOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). CONCLUSIONS By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.
Collapse
Affiliation(s)
- D J Apple
- Center for Research on Ocular Therapeutic and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina 29425-2236, USA
| | | | | | | | | | | | | | | |
Collapse
|
49
|
Macky TA, Trivedi RH, Werner L, Pandey SK, Izak AM, Apple DJ. Degeneration of ultraviolet absorber material and calcium deposits within the optic of a hydrophilic intraocular lens. Int Ophthalmol Clin 2001; 41:79-90. [PMID: 11481541 DOI: 10.1097/00004397-200107000-00008] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Affiliation(s)
- T A Macky
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
50
|
Affiliation(s)
- A M Izak
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|