1
|
Katafuchi A, Kamegawa M, Goto S, Kuwahara D, Osawa Y, Shimamoto S, Ishihara S, Ohtsuka A, Ijiri D. Effects of Cyclic High Ambient Temperature on Muscle Imidazole Dipeptide Content in Broiler Chickens. J Poult Sci 2024; 61:2024004. [PMID: 38304875 PMCID: PMC10824857 DOI: 10.2141/jpsa.2024004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 12/20/2023] [Indexed: 02/03/2024] Open
Abstract
Imidazole dipeptides possess important bioregulatory properties in animals. This study aimed to evaluate the effect of high ambient temperature on muscle imidazole dipeptides (carnosine, anserine, and balenine) in broiler chickens. Sixteen 14-day-old male broiler chickens were divided into two groups, which were reared under thermoneutral (25 ± 1 °C) or cyclic high ambient temperature (35 ± 1 °C for 8 h/day) for 4 weeks. Chickens exposed to cyclic high ambient temperatures displayed lower skeletal muscle anserine and carnosine content than control chickens. Balenine could not be detected in the pectoral muscle of either group. The pectoral muscles of broiler chickens kept under cyclic high-temperature exhibited significantly lower mRNA expression of carnosine synthase 1, which synthesizes carnosine and anserine; but a significantly higher mRNA expression of carnosinase 2, which degrades carnosine and anserine. Our results suggest that heat exposure decreases pectoral imidazole dipeptide content in broiler chickens. This may be attributed to a lower expression of imidazole dipeptide-synthesizing genes, but higher levels of genes involved in their degradation.
Collapse
Affiliation(s)
- Ayumi Katafuchi
- Graduate School of Agriculture, Forestry and Fisheries, Kagoshima University, 1-21-24 Korimoto, Kagoshima 890-0065, Japan
| | - Mizuki Kamegawa
- Graduate School of Agriculture, Forestry and Fisheries, Kagoshima University, 1-21-24 Korimoto, Kagoshima 890-0065, Japan
| | - Serina Goto
- Department of Agricultural Sciences and Natural Resources, Kagoshima University, Korimoto, Kagoshima 890-0065, Japan
| | - Daichi Kuwahara
- Biotechnology Group, Innovation Technology Center, Central Technical Research Laboratory, ENEOS Corporation, Chidori-Cho 8, Naka-ku, Yokohama 231-0815, Japan
| | - Yukiko Osawa
- Biotechnology Group, Innovation Technology Center, Central Technical Research Laboratory, ENEOS Corporation, Chidori-Cho 8, Naka-ku, Yokohama 231-0815, Japan
| | - Saki Shimamoto
- Graduate School of Science and Technology, Niigata University, 8050 Ikarashi 2-no-cho, Nishi-ku, Niigata 950-2181, Japan
| | - Shinya Ishihara
- Graduate School of Applied Life Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino, Tokyo 180-8602, Japan
| | - Akira Ohtsuka
- Graduate School of Agriculture, Forestry and Fisheries, Kagoshima University, 1-21-24 Korimoto, Kagoshima 890-0065, Japan
- Department of Agricultural Sciences and Natural Resources, Kagoshima University, Korimoto, Kagoshima 890-0065, Japan
| | - Daichi Ijiri
- Graduate School of Agriculture, Forestry and Fisheries, Kagoshima University, 1-21-24 Korimoto, Kagoshima 890-0065, Japan
- Department of Agricultural Sciences and Natural Resources, Kagoshima University, Korimoto, Kagoshima 890-0065, Japan
| |
Collapse
|
2
|
Osawa Y, Kuwahara D, Honda M. Enhanced Z-Isomerization of Astaxanthin in Paracoccus carotinifaciens via Microwave Drying. J Oleo Sci 2024; 73:163-168. [PMID: 38311406 DOI: 10.5650/jos.ess23093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024] Open
Abstract
The effects of microwave drying conditions of a Paracoccus carotinifaciens culture solution on astaxanthin Z-isomerization and degradation were investigated. The microwave drying significantly increase the ratio of astaxanthin Z-isomers, and the higher the microwave power and the longer the drying time, the higher the total Z-isomer ratio of astaxanthin, but such conditions also accelerated astaxanthin degradation. We found that the addition of powdered oils enhanced the Z-isomerization reaction. For example, when the P. carotinifaciens culture solution was dried at 1000 W power for 5 min without and with powdered rapeseed oil, total Z-isomer ratios of astaxanthin in resulting dried powder were 14.9 and 47.4%, respectively. Furthermore, the storage test of the dried P. carotinifaciens powder showed that astaxanthin Z- isomers were stable at 4℃ in a low-oxygen atmosphere. As astaxanthin Z-isomers have greater bioavailability and potentially exhibit superior biological activities than the all-E-isomer, the dried P. carotinifaciens powder obtained by the method of this study is expected to be used as a value-added astaxanthin source.
Collapse
Affiliation(s)
| | | | - Masaki Honda
- Faculty of Science & Technology, Meijo University
| |
Collapse
|
3
|
Osawa Y, Nishi R, Kuwahara D, Haga Y, Honda M. Improved Flesh Pigmentation of Rainbow Trout (Oncorhynchus mykiss) by Feeding Z-Isomer-Rich Astaxanthin Derived from Natural Origin. J Oleo Sci 2024; 73:35-43. [PMID: 38171729 DOI: 10.5650/jos.ess23064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024] Open
Abstract
The use of Paracoccus carotinifaciens-derived natural astaxanthin as an alternative to synthetic astaxanthin has attracted considerable attention from the aquaculture industry. Furthermore, to enhance the bioavailability of astaxanthin, its "Z-isomerization" has been actively studied in recent years. This study investigated the effects of feeding a diet containing astaxanthin rich in the all-E- or Z-isomers derived from P. carotinifaciens on the pigmentation and astaxanthin concentration in rainbow trout (Oncorhynchus mykiss) flesh. Z-Isomer-rich astaxanthin was prepared from the P. carotinifaciens-derived all-E-isomer by thermal treatment in fish oil, and the prepared all-E-isomer-rich astaxanthin diet (E-AST-D; total Z-isomerratio = 9.1%) and Z-isomer-rich astaxanthin diet (Z-AST-D; total Z-isomer ratio of astaxanthin = 56.6%) were fed to rainbow trout for 8 weeks. The feeding of Z-AST-D resulted in greater pigmentation and astaxanthin accumulation efficiency in the flesh than those fed E-AST-D. Specifically, when E-AST-D was fed to rainbow trout, the SalmoFan score and astaxanthin concentration of the flesh were 22.1±1.4 and 1.36±0.71 μg/g wet weight, respectively, whereas when Z-AST-D was fed, their values were 26.0±2.5 and 5.33±1.82 μg/g wet weight, respectively. These results suggest that P. carotinifaciens-derived astaxanthin Z- isomers prepared by thermal isomerization are more bioavailable to rainbow trout than the all-E-isomer.
Collapse
Affiliation(s)
| | - Ryuta Nishi
- Department of Marine Biosciences, Tokyo University of Marine Science and Technology
| | | | - Yutaka Haga
- Department of Marine Biosciences, Tokyo University of Marine Science and Technology
| | - Masaki Honda
- Faculty of Science & Technology, Meijo University
| |
Collapse
|
4
|
Osawa Y, Kuwahara D, Hayashi Y, Honda M. Effects of Astaxanthin Preparation Form on the Efficiency of Egg Yolk Pigmentation in Laying Hens. J Oleo Sci 2024; 73:25-34. [PMID: 38171728 DOI: 10.5650/jos.ess23048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024] Open
Abstract
This study investigated the effects of the preparation form of astaxanthin on egg yolk pigmentation and egg quality in laying hens. The following four astaxanthin sources were prepared in this study: (1) dried cell powder of Paracoccus carotinifaciens (Panaferd-AX), (2) fine cell powder of P. carotinifaciens (Panaferd-P), (3) astaxanthin oil suspension, and (4) water-soluble astaxanthin powder. These astaxanthin preparations were added to the basal diet at a final concentration of 2 mg/kg and fed to White Leghorn laying hens for 14 days. Although the administration of these astaxanthin preparations did not largely affect egg quality (i.e., egg weight, yolk weight, albumen height, and Haugh unit), feeding significantly improved astaxanthin concentration and yolk color fan score. When water-soluble astaxanthin powder was fed, the yolk astaxanthin concentration and color fan score were most improved, followed by Panaferd-P. These results indicated that astaxanthin pulverization and water solubilization significantly improved its bioavailability in laying hens. Furthermore, although diets rich in (all-E)-astaxanthin were fed to the hens, approximately 30% of astaxanthin was present as the Z-isomers in the egg yolk. These findings may contribute to improving not only the egg quality but the nutritional value of hen eggs.
Collapse
Affiliation(s)
| | | | | | - Masaki Honda
- Faculty of Science & Technology, Meijo University
| |
Collapse
|
5
|
Zhang Y, Takahama K, Osawa Y, Kuwahara D, Yamada R, Oyama KI, Honda M. Characteristics of LED light-induced geometrical isomerization and degradation of astaxanthin and improvement of the color value and crystallinity of astaxanthin utilizing the photoisomerization. Food Res Int 2023; 174:113553. [PMID: 37986432 DOI: 10.1016/j.foodres.2023.113553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 09/26/2023] [Accepted: 10/01/2023] [Indexed: 11/22/2023]
Abstract
The effects of light-emitting diode (LED) irradiation characterized by different emission wavelengths on the E/Z-isomerization and degradation of astaxanthin were investigated. LED irradiation slightly promoted Z-isomerization of astaxanthin, whereas the all-E-isomerization was highly efficiently promoted at specific wavelengths, especially at 365 nm. Astaxanthin isomers did not degrade significantly when dissolved in ethanol and subjected to LED irradiation conditions for 300 min. However, significant degradation was achieved when ethyl acetate was used for dissolution, and the samples were irradiated at the wavelength of 405 nm. The addition of α-tocopherol suppressed the photodegradation of astaxanthin. LED irradiation significantly affected the physical properties of astaxanthin Z-isomers. Irradiation with 365, 405, and 470 nm LEDs enhanced the color value (redness) and crystallinity of the Z-isomers via an all-E-isomerization reaction. These findings can contribute to the development of technologies that can arbitrarily control the E/Z-isomer ratio and physical properties of astaxanthin.
Collapse
Affiliation(s)
- Yelin Zhang
- Department of Chemistry, Faculty of Science & Technology, Meijo University, 1-501 Shiogamaguchi, Tempaku-ku, Nagoya, Aichi 468-8502, Japan; Department of Materials Process Engineering, Nagoya University, Furo-cho, Nagoya, Aichi 464-8601, Japan
| | - Kentaro Takahama
- Technical Center, Nagoya University, Furo-cho, Nagoya, Aichi 464-8601, Japan
| | - Yukiko Osawa
- Biotechnology R&D Group, ENEOS Corporation, 8 Chidoricho, Naka-ku, Yokohama, Kanagawa 231-0815, Japan
| | - Daichi Kuwahara
- Biotechnology R&D Group, ENEOS Corporation, 8 Chidoricho, Naka-ku, Yokohama, Kanagawa 231-0815, Japan
| | - Rio Yamada
- Chemical Instrumentation Facility, Research Center for Materials Science, Nagoya University, Furo-cho, Nagoya, Aichi 464-8602, Japan
| | - Kin-Ichi Oyama
- Chemical Instrumentation Facility, Research Center for Materials Science, Nagoya University, Furo-cho, Nagoya, Aichi 464-8602, Japan
| | - Masaki Honda
- Department of Chemistry, Faculty of Science & Technology, Meijo University, 1-501 Shiogamaguchi, Tempaku-ku, Nagoya, Aichi 468-8502, Japan.
| |
Collapse
|
6
|
Kawasaki Y, Kozaneyori A, Suda T, Yamamoto K, Kuwahara D, Yoshio T, Shintaku H, Matsumoto H. Pneumocystis pneumonia diagnosed by repeated measurements of β-D-glucan levels. Respir Med Case Rep 2023; 45:101905. [PMID: 37577120 PMCID: PMC10415786 DOI: 10.1016/j.rmcr.2023.101905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 07/19/2023] [Accepted: 07/30/2023] [Indexed: 08/15/2023] Open
Abstract
β-D-glucan is extensively employed as a supplementary diagnostic tool for Pneumocystis pneumonia (PCP) and typically yields positive results in most cases. We present a case of a 73-year-old woman with a history of rheumatoid arthritis, who was receiving biological agents and was admitted due to pneumonia. Initially, the β-D-glucan test was negative. However, as the disease progressed, it eventually turned positive, leading to the diagnosis of PCP. The patient was treated with corticosteroids and trimethoprim-sulfamethoxazole, resulting in pneumonia resolution. Our findings suggest that repeated assessment of β-D-glucan levels holds diagnostic value in patients without human immunodeficiency virus infection.
Collapse
Affiliation(s)
- Yasutaka Kawasaki
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Akito Kozaneyori
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Takuya Suda
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Kohei Yamamoto
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Daichi Kuwahara
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Takatoshi Yoshio
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Hiroaki Shintaku
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| | - Hiroshi Matsumoto
- Department of Internal Medicine, Wajima Municipal Hospital, Wajima-shi, Japan
| |
Collapse
|
7
|
Kuwahara D, Okazaki A. “Burgundy wine” pleural effusion: An unusual manifestation of acute bacterial empyema. Clin Case Rep 2022; 10:e05486. [PMID: 35228884 PMCID: PMC8864636 DOI: 10.1002/ccr3.5486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/29/2022] [Accepted: 02/08/2022] [Indexed: 11/13/2022] Open
Abstract
Although empyema diagnosis by thoracentesis is relatively straightforward, the pleural effusion can sometimes be bloody rather than purulent. We report a case of acute empyema with a dark‐red bloody effusion, wherein multiple anaerobic bacteria were detected. Chest imaging findings improved with pleural drainage, intrapleural fibrinolytic therapy, and intravenous antibiotic treatment.
Collapse
Affiliation(s)
- Daichi Kuwahara
- Department of Respiratory Medicine Kaga Medical Center Kaga, Ishikawa Japan
| | - Akihito Okazaki
- Department of Respiratory Medicine Kaga Medical Center Kaga, Ishikawa Japan
| |
Collapse
|
8
|
Shinohara S, Kuwahara D, Ishigami Y, Horita H, Nakanishi S. Extremely small-diameter, high-density, radio frequency, plasma sources and central gas feeding for next-generation electrodeless plasma thrusters. Rev Sci Instrum 2020; 91:073507. [PMID: 32752823 DOI: 10.1063/5.0003387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Accepted: 07/03/2020] [Indexed: 06/11/2023]
Abstract
Radio frequency (RF) waves including helicon waves can readily produce high-electron-density (ne up to 1013 cm-3) plasmas with a broad range of external operating parameters. Various featured RF and helicon sources in a wide range of scales are suitable for plasma propulsion schemes. Electrodeless RF plasmas have no direct contact between electrodes and antennas, which enables long-life operation. However, one of the crucial problems is to reduce the plasma size for future applications in nano- and pico-satellites. Diagnostics of the plasma parameters in a small area should also be improved. Furthermore, to increase plasma performance, it is important to consider the radial electron density (ne) profile with an increasing upper limit, observed in high-density helicon sources due to the depletion of neutrals. This problem may be controlled by the location of neutral gas feeding and knowledge of the gas pressure distribution. Here, production of RF plasmas, with extremely small diameters from 3-mm down to 0.5-mm including 1-mm, was demonstrated, and characterization of ne and the electron temperature was performed with a collisional radiative model. Finally, to improve plasma performance such as ne and the thrust force, internal gas feeding was demonstrated using a developed Pirani gauge to measure neutral density.
Collapse
Affiliation(s)
- S Shinohara
- Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - D Kuwahara
- Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - Y Ishigami
- Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - H Horita
- Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - S Nakanishi
- Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| |
Collapse
|
9
|
Fujiwara M, Kuwahara D, Hayashi M, Zendo T, Sato M, Nakayama J, Sonomoto K. Lowering effect of viable Pediococcus pentosaceus QU 19 on the rise in postprandial glucose. Biosci Microbiota Food Health 2020; 39:57-64. [PMID: 32328401 PMCID: PMC7162691 DOI: 10.12938/bmfh.19-041] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Accepted: 12/31/2019] [Indexed: 01/31/2023]
Abstract
In the present study, we investigated the glucose-decreasing action of lactic acid bacteria (LAB). The finding of this study could be helpful for people in controlling their blood sugar
levels. The LAB candidate was isolated from a Japanese fermented food and identified as Pediococcus pentosaceus by an analysis of its genome sequence. Postprandial blood
glucose elevation was investigated using oral starch tolerance tests in mice. Normal mice were fed starch and lyophilized cells of P. pentosaceus QU 19 at the same time.
Even without pre-administration of P. pentosaceus QU 19, elevation of the blood glucose level was significantly suppressed by the intake of P. pentosaceus
QU 19 at the same time as oral administration of starch. According to the results for its survival in simulated digestive juice and the reduction of blood glucose level in mice, P.
pentosaceus QU 19 has potential hypoglycemic activity. In vitro measurements revealed that the glucose-decreasing action of P. pentosaceus QU 19
is probably caused by the glucose assimilation of the strain, not the inhibition of carbohydrate-splitting enzymes which has been reported for other LABs previously. These findings indicate
that specific strains of LAB, especially P. pentosaceus QU 19, and foods fermented by LAB may be beneficial for people who must manage glucose ingestion.
Collapse
Affiliation(s)
- Miki Fujiwara
- Biotechnology R&D Group, HPM Research & Development Department, High Performance Materials Company, JXTG Nippon Oil & Energy Corporation, 8 Chidoricho, Naka-ku, Yokohama 231-0815, Japan.,Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Daichi Kuwahara
- Biotechnology R&D Group, HPM Research & Development Department, High Performance Materials Company, JXTG Nippon Oil & Energy Corporation, 8 Chidoricho, Naka-ku, Yokohama 231-0815, Japan
| | - Masahiro Hayashi
- Biotechnology R&D Group, HPM Research & Development Department, High Performance Materials Company, JXTG Nippon Oil & Energy Corporation, 8 Chidoricho, Naka-ku, Yokohama 231-0815, Japan
| | - Takeshi Zendo
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Masao Sato
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Jiro Nakayama
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Kenji Sonomoto
- Department of Bioscience and Biotechnology, Faculty of Agriculture, Graduate School, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| |
Collapse
|
10
|
Furukawa T, Takizawa K, Yano K, Kuwahara D, Shinohara S. Spatial measurement in rotating magnetic field plasma acceleration method by using two-dimensional scanning instrument and thrust stand. Rev Sci Instrum 2018; 89:043505. [PMID: 29716344 DOI: 10.1063/1.5013214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A two-dimensional scanning probe instrument has been developed to survey spatial plasma characteristics in our electrodeless plasma acceleration schemes. In particular, diagnostics of plasma parameters, e.g., plasma density, temperature, velocity, and excited magnetic field, are essential for elucidating physical phenomena since we have been concentrating on next generation plasma propulsion methods, e.g., Rotating Magnetic Field plasma acceleration method, by characterizing the plasma performance. Moreover, in order to estimate the thrust performance in our experimental scheme, we have also mounted a thrust stand, which has a target type, on this movable instrument, and scanned the axial profile of the thrust performance in the presence of the external magnetic field generated by using permanent magnets, so as to investigate the plasma captured in a stand area, considering the divergent field lines in the downstream region of a generation antenna. In this paper, we will introduce the novel measurement instrument and describe how to measure these parameters.
Collapse
Affiliation(s)
- T Furukawa
- The Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - K Takizawa
- The Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - K Yano
- The Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - D Kuwahara
- Institute of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - S Shinohara
- Institute of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| |
Collapse
|
11
|
Tokuzawa T, Kawahata K, Nagayama Y, Inagaki S, De Vries PC, Mase A, Kogi Y, Yokota Y, Hojo H, Tanaka K, Ejiri A, Pavlichenko RO, Yamaguchi S, Yoshinaga T, Kuwahara D, Shi Z, Tsuchiya H, Ito Y, Hirokura S, Sudo S, Komori A. Developments of Electron Cyclotron Emission Spectroscopy and Microwave Reflectometry on LHD. Fusion Science and Technology 2017. [DOI: 10.13182/fst10-a10822] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- T. Tokuzawa
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - K. Kawahata
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - Y. Nagayama
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - S. Inagaki
- Research Institute for Applied Mechanics, Kyushu University, Fukuoka 816-8580, Japan
| | - P. C. De Vries
- Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon OX14 3EA, United Kingdom
| | - A. Mase
- Art Science and Technology Center for Cooperative Research, Kyushu University, Kasuga 816-8560, Japan
| | - Y. Kogi
- Art Science and Technology Center for Cooperative Research, Kyushu University, Kasuga 816-8560, Japan
| | - Y. Yokota
- Art Science and Technology Center for Cooperative Research, Kyushu University, Kasuga 816-8560, Japan
| | - H. Hojo
- Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan
| | - K. Tanaka
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - A. Ejiri
- Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa 277-8561, Japan
| | - R. O. Pavlichenko
- Institute of Plasma Physics, National Science Center, Kharkov Institute of Physics and Technology 1, Akademicheskaya St., Kharkov, 61108, Ukraine
| | - S. Yamaguchi
- Faculty of Engineering Science, Kansai University, Osaka 564-8680, Japan
| | - T. Yoshinaga
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - D. Kuwahara
- Tokyo Institute of Technology, Tokyo 152-8550, Japan
| | - Z. Shi
- Graduate University for Advanced Studies, Toki 509-5292, Japan
| | - H. Tsuchiya
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - Y. Ito
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - S. Hirokura
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - S. Sudo
- National Institute for Fusion Science, Toki 509-5292, Japan
| | - A. Komori
- National Institute for Fusion Science, Toki 509-5292, Japan
| | | |
Collapse
|
12
|
Nagayama Y, Ito N, Kuwahara D, Tsuchiya H, Yamaguchi S. Development of 2-D horn-antenna millimeter-wave imaging device (HMID) for the plasma diagnostics. Rev Sci Instrum 2017; 88:044703. [PMID: 28456234 DOI: 10.1063/1.4980150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The two-dimensional (2-D) Horn-antenna Millimeter-wave Imaging Device (HMID) has been developed for the O-mode Microwave Imaging Reflectometry (O-MIR) in the Large Helical Device (LHD). The detectable frequency range of the HMID is 23-33 GHz, which corresponds to the cutoff electron density of 0.8-1.5 × 1019 m-3 in the O-MIR. The HMID is a 2-D imaging device that improves on the horn-antenna mixer array, which had been developed for the X-mode MIR in the LHD. In the HMID, the signal (RF) wave from the horn antenna is transmitted to the microstrip line by the finline transmitter, and this is mixed by the double-balanced-mixer with the local oscillation wave that is fed by a coaxial cable. By using the HMID, the MIR optical system can be significantly simplified.
Collapse
Affiliation(s)
- Y Nagayama
- National Institute for Fusion Science, National Institute for Natural Sciences, Toki 509-5292, Japan
| | - N Ito
- National Institute of Technology, Ube College, Ube 755-8555, Japan
| | - D Kuwahara
- Tokyo University of Agriculture and Technology, Koganei 184-8588, Japan
| | - H Tsuchiya
- National Institute for Fusion Science, National Institute for Natural Sciences, Toki 509-5292, Japan
| | | |
Collapse
|
13
|
Wang X, Kanno S, Kohagura J, Yoshikawa M, Shima Y, Nakashima Y, Sakamoto M, Oki K, Imai T, Ichimura M, Nagayama Y, Kuwahara D, Mase A. A Novel Frequency-Multiplied Interferometer System with 1-D Horn-Antenna Mixer Array in the GAMMA 10/PDX End Divertor Module. Fusion Science and Technology 2017. [DOI: 10.13182/fst14-877] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- X. Wang
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - S. Kanno
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - J. Kohagura
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - M. Yoshikawa
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - Y. Shima
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - Y. Nakashima
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - M. Sakamoto
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - K. Oki
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - T. Imai
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - M. Ichimura
- University of Tsukuba, Plasma Research Center, Tsukuba, Ibaraki, Japan
| | - Y. Nagayama
- National Institute for Fusion Science, Toki, Gifu, Japan
| | - D. Kuwahara
- Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | - A. Mase
- Kyushu University, KASTEC, Kasuga, Fukuoka, Japan
| |
Collapse
|
14
|
Kohagura J, Yoshikawa M, Wang X, Kuwahara D, Ito N, Nagayama Y, Shima Y, Nojiri K, Sakamoto M, Nakashima Y, Mase A. A 60-GHz interferometer with a local oscillator integrated antenna array for divertor simulation experiments on GAMMA 10/PDX. Rev Sci Instrum 2016; 87:11E127. [PMID: 27910479 DOI: 10.1063/1.4961292] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In conventional multichannel/imaging microwave diagnostics of interferometry, reflectometry, and electron cyclotron emission measurements, a local oscillator (LO) signal is commonly supplied to a receiver array via irradiation using LO optics. In this work, we present a 60-GHz interferometer with a new eight-channel receiver array, called a local oscillator integrated antenna array (LIA). An outstanding feature of LIA is that it incorporates a frequency quadrupler integrated circuit for LO supply to each channel. This enables simple and uniform LO supply to the receiver array using only a 15-GHz LO source and a coaxial cable transmission line instead of using an expensive 60-GHz source, LO optics, and a waveguide transmission line. The new interferometer system is first applied to measure electron line-averaged density inside the divertor simulation experimental module (D-module) on GAMMA 10/PDX tandem mirror device.
Collapse
Affiliation(s)
- J Kohagura
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - M Yoshikawa
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - X Wang
- Saitama University, Saitama 338-8570, Japan
| | - D Kuwahara
- Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan
| | - N Ito
- National Institute of Technology, Ube College, Ube, Yamaguchi 755-8555, Japan
| | - Y Nagayama
- National Institute of Fusion Science, Toki, Gifu 509-5292, Japan
| | - Y Shima
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - K Nojiri
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - M Sakamoto
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - Y Nakashima
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - A Mase
- Kyushu University, Kasuga, Fukuoka 816-8580, Japan
| |
Collapse
|
15
|
Kogi Y, Higashi T, Matsukawa S, Mase A, Kohagura J, Nagayama Y, Kawahata K, Kuwahara D, Yoshikawa M. Validation experiment of a numerically processed millimeter-wave interferometer in a laboratory. Rev Sci Instrum 2014; 85:11D411. [PMID: 25430174 DOI: 10.1063/1.4893430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We propose a new interferometer system for density profile measurements. This system produces multiple measurement chords by a leaky-wave antenna driven by multiple frequency inputs. The proposed system was validated in laboratory evaluation experiments. We confirmed that the interferometer generates a clear image of a Teflon plate as well as the phase shift corresponding to the plate thickness. In another experiment, we confirmed that quasi-optical mirrors can produce multiple measurement chords; however, the finite spot size of the probe beam degrades the sharpness of the resulting image.
Collapse
Affiliation(s)
- Y Kogi
- Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka 811-0295, Japan
| | - T Higashi
- Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka 811-0295, Japan
| | - S Matsukawa
- Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka 811-0295, Japan
| | - A Mase
- Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga, Fukuoka 816-0811, Japan
| | - J Kohagura
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - Y Nagayama
- National Institute for Fusion Science, Toki, Gifu 509-5202, Japan
| | - K Kawahata
- National Institute for Fusion Science, Toki, Gifu 509-5202, Japan
| | - D Kuwahara
- Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan
| | - M Yoshikawa
- Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| |
Collapse
|
16
|
Kuwahara D, Ito N, Nagayama Y, Yoshinaga T, Yamaguchi S, Yoshikawa M, Kohagura J, Sugito S, Kogi Y, Mase A. Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics. Rev Sci Instrum 2014; 85:11D805. [PMID: 25430218 DOI: 10.1063/1.4885471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.
Collapse
Affiliation(s)
- D Kuwahara
- Department of Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan
| | - N Ito
- Department of Intelligent System Engineering, Ube National College of Technology, Ube, Yamaguchi 755-8555, Japan
| | - Y Nagayama
- Department of Helical Plasma Research, National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
| | - T Yoshinaga
- Department of Applied Physics, National Defense Academy, Yokosuka, Kanagawa 239-0811, Japan
| | - S Yamaguchi
- Department of Pure and Applied Physics, Kansai University, Suita, Osaka 564-8680, Japan
| | - M Yoshikawa
- Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - J Kohagura
- Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
| | - S Sugito
- Equipment Development Center, Institute for Molecular Science, Okazaki, Aichi 444-8585, Japan
| | - Y Kogi
- Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka, Fukuoka 811-0295, Japan
| | - A Mase
- Art, Science and Technology Center for Cooperative Research, Kyusyu University, Kasuga, Fukuoka 816-8580, Japan
| |
Collapse
|
17
|
Kuwahara D, Hasumi T, Kaneko H, Unno M, Takahashi D, Toshima K. A solid-phase affinity labeling method for target-selective isolation and modification of proteins. Chem Commun (Camb) 2014; 50:15601-4. [PMID: 25360454 DOI: 10.1039/c4cc06783e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Solid-phase affinity labeling of a target protein, peanut agglutinin (PNA), with the specifically designed chemical tool 1 selectively and effectively furnished the labeled PNA. Furthermore, this method was applicable to native human carbonic anhydrase II in red blood cell lysate using the chemical tool 2 without the need for tedious manipulations.
Collapse
Affiliation(s)
- Daichi Kuwahara
- Department of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
| | | | | | | | | | | |
Collapse
|
18
|
Kuwahara D, Mishio A, Nakagawa T, Shinohara S. Development of very small-diameter, inductively coupled magnetized plasma device. Rev Sci Instrum 2013; 84:103502. [PMID: 24182105 DOI: 10.1063/1.4823524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (~10(19) m(-3)) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ~1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG.
Collapse
Affiliation(s)
- D Kuwahara
- Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588, Japan
| | | | | | | |
Collapse
|
19
|
Nagayama Y, Kuwahara D, Yoshinaga T, Hamada Y, Kogi Y, Mase A, Tsuchiya H, Tsuji-Iio S, Yamaguchi S. Development of 3D microwave imaging reflectometry in LHD (invited). Rev Sci Instrum 2012; 83:10E305. [PMID: 23126965 DOI: 10.1063/1.4729259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Three-dimensional (3D) microwave imaging reflectometry has been developed in the large helical device to visualize fluctuating reflection surface which is caused by the density fluctuations. The plasma is illuminated by the probe wave with four frequencies, which correspond to four radial positions. The imaging optics makes the image of cut-off surface onto the 2D (7 × 7 channels) horn antenna mixer arrays. Multi-channel receivers have been also developed using micro-strip-line technology to handle many channels at reasonable cost. This system is first applied to observe the edge harmonic oscillation (EHO), which is an MHD mode with many harmonics that appears in the edge plasma. A narrow structure along field lines is observed during EHO.
Collapse
Affiliation(s)
- Y Nagayama
- National Institute for Fusion Science, Toki, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Yoshinaga T, Nagayama Y, Kuwahara D, Tsuchiya H, Yamaguchi S, Kogi Y, Tsuji-Iio S, Mase A. Simultaneous projection and detection system of four different frequencies for microwave imaging reflectometry in Large Helical Device. Rev Sci Instrum 2010; 81:10D915. [PMID: 21033947 DOI: 10.1063/1.3491197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.
Collapse
Affiliation(s)
- T Yoshinaga
- National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Kuwahara D, Tsuji-Iio S, Nagayama Y, Yoshinaga T, Tsuchiya H, Sugito S, Yamaguchi S, Kogi Y, Akaki K, Mase A. Development of electron cyclotron emission imaging system on Large Helical Device. Rev Sci Instrum 2010; 81:10D919. [PMID: 21033951 DOI: 10.1063/1.3491223] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.
Collapse
Affiliation(s)
- D Kuwahara
- Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro, Tokyo 152-8550, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Kogi Y, Jeong SH, Lee KD, Akaki K, Mase A, Kuwahara D, Yoshinaga T, Nagayama Y, Kwon M, Kawahata K. Calibration of electron cyclotron emission radiometer for KSTAR. Rev Sci Instrum 2010; 81:10D916. [PMID: 21033948 DOI: 10.1063/1.3491304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.
Collapse
Affiliation(s)
- Y Kogi
- Fukuoka Institute of Technology, Fukuoka 811-0295, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Yamaguchi S, Nagayama Y, Kuwahara D, Yoshinaga T, Shi ZB, Kogi Y, Mase A. Development of microwave imaging reflectometry in large helical device. Rev Sci Instrum 2008; 79:10F111. [PMID: 19044595 DOI: 10.1063/1.2993741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Three key devices of the microwave imaging reflectometry (MIR) are under development in large helical device (LHD). The 2-D mixer array is developed by stacking the one-dimensional array of the planar Yagi-Uda antenna. The new type of the bandpass filter bank is modified to match the requirement of the MIR. The low-cost quadrature demodulator is also developed for the phase detection system. By using the low-price commercial wireless devices, the development cost becomes much lower than the expensive waveguide system. These devices enable the development of 2-D/3-D microwave imaging system for the plasma diagnostics and industrial applications.
Collapse
Affiliation(s)
- S Yamaguchi
- Faculty of Engineering Science, Kansai University, Osaka 564-8680, Japan
| | | | | | | | | | | | | |
Collapse
|
24
|
Kobayashi T, Tsutsumi K, Kuwahara D, Iwatake H, Takakuwa T. [Resistance to Fas-mediated apoptosis in human papillomavirus type 16-immortalized human laryngeal epithelial cells after tumorigenesis]. Nihon Jibiinkoka Gakkai Kaiho 2001; 104:139-46. [PMID: 11257778 DOI: 10.3950/jibiinkoka.104.139] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Apoptosis plays an important role in such biological processes as multistep carcinogenesis. Human papillomavirus type 16(HPV16)-immortalized human epithelial cell lines are, for the most part, nontumorigenic in nude mice and useful for studying mechanisms involved in multistep carcinogenesis. We previously reported that HPV16-immortalized human laryngeal epithelial cell line HLEC16 formed tumors after treatment with 4-(methyl-nitrosamine)-1-(3-pyridyl)-1-butanone, and derived one tumorigenic cell line, HLEC16T. We compared sensitivity to Fas receptor-mediated apoptosis of nontumorigenic HLEC16 and tumorigenic HLEC16T. HLEC16 and HLEC16T expressed Fas protein (Fas) but not Fas-ligand (FasL) mRNA. We applied an anti-Fas monoclonal, antibody, CH11, to HLEC16 and HLEC16T, and monitored cell death. HLEC16T was found to be significantly less sensitive to CH11-mediated cell death that HLEC16. Western blot analysis showed no significant difference in levels of apoptosis-inducing protein, Bax, between HLEC16 and HLEC16T. Levels of apoptosis-inhibiting proteins Bcl-2 and Bcl-XL increased in HLEC16T. These results suggest that the inhibition of Fas-mediated apoptosis through apoptosis-inhibiting protein overexpression may promote tumorigenicity in HLEC16T.
Collapse
Affiliation(s)
- T Kobayashi
- Department of Otolaryngology, St. Marianna University School of Medicine, Kawasaki
| | | | | | | | | |
Collapse
|
25
|
Otani Y, Kuwahara D, Tsutsumi K. [Resistance to Fas-mediated apoptosis in head and neck squamous cell carcinoma cells]. Nihon Jibiinkoka Gakkai Kaiho 2000; 103:1169-76. [PMID: 11109827 DOI: 10.3950/jibiinkoka.103.1169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Various types of carcinoma cells have been shown to escape immune recognition by constitutive resistance to Fas receptor (Fas)-mediated apoptosis. The purpose of this study was to examine the sensitivity to Fas-mediated apoptosis of human head and neck squamous cell carcinoma (HNSCC) cells. We applied an anti-Fas monoclonal antibody (CH11) to HNSCC cell lines and monitored their cell death. All three HNSCC cell lines examined expressed Fas protein but not Fas-ligand mRNA. CH11 did not induce cell death (CH11-resistant) in any of the three HNSCC cell lines examined. Treatment with actinomycin D (ActD) converted the phenotypes of the CH11-resistant HNSCC cell lines from CH11-resistant to CH11-sensitive, suggesting that the resistance to CH11-induced apoptosis was dependent on RNA synthesis. Western blot analysis did not show any differences in expression of Bcl-2 between the non-treated and ActD-treated HNSCC cell lines. Expression of Bcl-XL, on the other hand, was greatly reduced in the ActD-treated HNSCC cell lines, implying that Fas signaling in the CH11-resistant HNSCC cell lines might be regulated by an Bcl-XL-inhibitable step.
Collapse
Affiliation(s)
- Y Otani
- Department of Otolaryngology, St. Marianna University School of Medicine, Kanagawa
| | | | | |
Collapse
|
26
|
Kuwahara D, Tsutsumi K, Kobayashi T, Hasunuma T, Nishioka K. Caspase-9 regulates cisplatin-induced apoptosis in human head and neck squamous cell carcinoma cells. Cancer Lett 2000; 148:65-71. [PMID: 10680594 DOI: 10.1016/s0304-3835(99)00315-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The aim of this study was to understand the molecular requirements for cisplatin-induced apoptosis in human head and neck squamous cell carcinoma (HNSCC) cell death. Cisplatin induced apoptosis in HNSCC cell lines, HSC-2, HSC-3 and HSC-4 in a dose-dependent manner. However, cisplatin did not induce the expression of Fas-ligand mRNA or upregulation of Fas protein. By caspase activation assays, cisplatin induced Caspase-3 (Casp-3), -8 and -9 activation. In all three lines tested, the use of a specific inhibitor of Casp-9 almost completely blocked cisplatin-induced apoptosis, while the use of Casp-3 and -8 inhibitors resulted in a partial blockade of cisplatin-induced apoptosis. Our results strongly suggest that Casp-9-dependent apoptosis plays an important role in cisplatin-induced HNSCC apoptosis.
Collapse
Affiliation(s)
- D Kuwahara
- Department of Otorhinolaryngology, St. Marianna University School of Medicine, Kawasaki, Kanagawa, Japan
| | | | | | | | | |
Collapse
|
27
|
Hirashima T, Kuwahara D, Nishi M. Morphology of lymphatics in the canine large intestine. Lymphology 1984; 17:69-72. [PMID: 6471918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The finer distribution of lymphatics in the large intestine of adult dogs was morphologically examined by puncture injection of colored dyes, intra-arterial injection of silver nitrate mixed with India ink, and electron microscopy. In the lamina propria there was a double-layer of lymphatic channels - a shallow network (near the mucosal surface) and a deep compartment (just above the muscularis mucosae). Sparse lymph capillaries also extended vertically paralleling intestinal glands. Some lymphatics penetrated into the submucosa where they demonstrated prominent valves and formed collecting lymphatic trunks alongside blood vessels.
Collapse
|
28
|
Nishi M, Uehara H, Ishizawa T, Kuwahara D, Yoshii H, Yotsumoto K, Aiko T. [Chemotherapy and immunochemotherapy in colorectal neoplasms]. Nihon Rinsho 1981; 39:2180-7. [PMID: 7026835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
29
|
Kuwahara D. [Microangiographic study on cancer of the large intestine - especially, the basic type of the vascular structure and the vascular change with growth of cancer (author's transl)]. Igaku Kenkyu 1980; 50:269-96. [PMID: 7304102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|