1
|
Murtada K, Pawliszyn J. Evaluation of thin film microextraction based on graphene oxide/ polymer composite: Experimental and theoretical insights. Talanta 2024; 274:126032. [PMID: 38581851 DOI: 10.1016/j.talanta.2024.126032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 03/28/2024] [Accepted: 04/01/2024] [Indexed: 04/08/2024]
Abstract
Experimental and theoretical assessments of a graphene oxide-based polymer as adsorbent for thin film microextraction (TFME) were conducted as part of this research. Graphene oxide (GO) was embedded in the organic polymer poly(styrene-co-divinylbenzene) (PS-DVB) to prepare a sorbent suitable for direct-immersion TFME. A TFME membrane coating prepared with the GO/PS-DVB sorbent and polydimethylsiloxane (PDMS) as binder was then applied for extraction of organic pollutants from aqueous and gaseous samples. The surface morphology of the TFME coating was examined by scanning electron microscopy (SEM). Various TFME parameters influencing extraction efficiency, such as extraction time and temperature, desorption temperature, and ionic strength, were investigated and optimized. In a comparison of TFME membranes, the GO/PS-DVB/PDMS TFME membrane was shown to yield higher extraction efficiencies for the targeted analytes than the pure PDMS and DVB/PDMS TFME membranes. The calibration graphs of the organic pollutants displayed linearity for most of the target analytes within the 10-2000 ng L-1 concentration range. The repeatability (RSD %, n = 5) and reproducibility (RSD %, n = 3) of the method were in the ranges of 2.2-5.9 %, and 3.2-8.5 %, respectively, at a concentration level of 500 ng L-1, whereas accuracy (%) ranged between 79.8 and 119 %. The developed method was successfully applied for determinations of organic pollutants in tap water, lake water, and wastewater samples. Furthermore, the impact of mass transfer kinetics on extractions by the GO/PS-DVB/PDMS TFME membrane from gaseous samples was theoretically discussed and experimentally verified. The results of this work demonstrate that the GO/PS-DVB/PDMS TFME method is a simple, efficient, and environmentally friendly method for pre-treatment of organic pollutants.
Collapse
Affiliation(s)
- Khaled Murtada
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
2
|
Wieczorek MN, Zhou W, Jeleń HH, Pawliszyn J. Automated sequential SPME addressing the displacement effect in food samples. Food Chem 2024; 439:138093. [PMID: 38043285 DOI: 10.1016/j.foodchem.2023.138093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/22/2023] [Accepted: 11/25/2023] [Indexed: 12/05/2023]
Abstract
The displacement effect can be an issue for the quantitation of analytes with low affinity towards the extraction phase in solid-phase microextraction (SPME) for food samples that have low level of binding matrix or high level of hydrophobic compounds. In this communication, automated sequential SPME-GC-MS strategy was developed for addressing the displacement issue. The SPME thin film with PDMS coating was firstly used for the extraction of hydrophobic components in the sample which cause displacement and then SPME fiber with DVB/CAR/PDMS coating was applied in the second step for the extraction of the remain compounds. This new strategy was investigated by using 10 key food odorants as target analytes and tested in commercial beer samples. The results suggested that sequential SPME can decrease the displacement effect and improve the extraction efficiency for polar analytes.
Collapse
Affiliation(s)
- Martyna N Wieczorek
- Faculty of Food Science and Nutrition, Poznań University of Life Sciences, Poznań, Poland
| | - Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Henryk H Jeleń
- Faculty of Food Science and Nutrition, Poznań University of Life Sciences, Poznań, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
| |
Collapse
|
3
|
Jiang RW, Marin LM, Jaroch K, Zhou W, Siqueira WL, Pawliszyn J. Proteomic Analysis of Human Saliva via Solid-Phase Microextraction Coupled with Liquid Chromatography-Mass Spectrometry. Anal Chem 2024; 96:5363-5367. [PMID: 38535996 DOI: 10.1021/acs.analchem.4c00307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Proteomics of human saliva samples was achieved for the first time via biocompatible solid-phase microextraction (bio-SPME) devices. Upon introduction of a porogen to a conventional C18 coating, porous C18/polyacrylonitrile (PAN) SPME blades were able to extract peptides up to 3.0 kDa and more peptides than commercial SPME blades. Following Trypsin digestion, salivary proteomic analysis was achieved via SPME-LC-MS/MS. Seven endogenous proteins were consistently identified in all saliva samples via bio-SPME. Taking advantage of this strategy, untargeted peptidomics was applied for the comparison of saliva samples between healthy and SARS-CoV-2 positive individuals. The results showed clear peptidomic differences between the viral and healthy saliva samples. This proof-of-concept study demonstrates the potential of bio-SPME-LC-MS/MS for peptidomics and proteomics in biomedical applications.
Collapse
Affiliation(s)
- Runshan W Jiang
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Lina M Marin
- College of Dentistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5E5, Canada
| | - Karol Jaroch
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz 85-089, Poland
| | - Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Walter L Siqueira
- College of Dentistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5E5, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
4
|
Zhou W, Pawliszyn J. Perspective on SPME-MS: Green and high-performance methods for rapid screening. Anal Chim Acta 2024; 1291:342244. [PMID: 38280787 DOI: 10.1016/j.aca.2024.342244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 12/30/2023] [Accepted: 01/12/2024] [Indexed: 01/29/2024]
Abstract
The direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS) offers rapid analysis with high sensitivity and low matrix effects by benefiting from the integration of sampling, high enrichment, and clean-up functions of SPME. Eliminating chromatographic separation reduces the amount of gas/solvent needed for analysis, while direct desorption in SPME-MS consumes none or few microliters of organic solvents per sample, further enhancing the greenness of the SPME technology. Over the past two decades, the rapid evolution of SPME-MS has given rise to numerous novel technologies that employ diverse ionization techniques and interfaces, several of which have already been commercialized. Drawing from an extensive review published earlier this year and our research experience, we provide perspectives on three aspects of these technologies: interface design and automation, integration with state-of-art MS instrumentation, and anticipated future developments.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
5
|
Xu S, Li H, Xiao L, Wang M, Feng S, Fan J, Pawliszyn J. Quantitative Determination of Poly(methyl Methacrylate) Micro/Nanoplastics by Cooling-Assisted Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry: Theoretical and Experimental Insights. Anal Chem 2024; 96:2227-2235. [PMID: 38272489 DOI: 10.1021/acs.analchem.3c05316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Determinations of micro/nanoplastics (MNPs) in environmental samples are essential to assess the extent of their presence in the environment and their potential impact on ecosystems and human health. With the aim to provide a sensitive method with simplified pretreatment steps, cooling-assisted solid-phase microextraction (CA-SPME) coupled to gas chromatography-mass spectrometry (GC-MS) is proposed as a new approach to quantify mass concentrations of MNPs in water and soil samples. The herein proposed CA-SPME method offers the unique advantage of integrating the thermal decomposition of MNPs and enrichment of signature compounds into one step. Poly(methyl methacrylate) (PMMA) was used as a model substance to verify the method performance in this work. Theoretical insights demonstrated that pyrolysis is the rate-determining step during the extraction process and that PMMA is effectively decomposed at 350 °C with an estimated incubation time of 13 min. Eight compounds were identified in the pyrolysis products by CA-SPME-GC-MS with the use of a DVB/CAR/PDMS coating, wherein methyl methacrylate was considered as the best indicator and dimethyl 2-methylenesuccinate was selected as the confirmation compound. Under the optimized conditions, the proposed method exhibited wide linearity (0.5-2000 μg for water and 5-1000 μg for soil) and high sensitivity, with limits of detection of 0.014 and 0.28 μg for water and soil, respectively. Finally, the proposed method was successfully applied for determinations of PMMA MNPs in real water and soil samples with satisfactory recoveries attained. The method only required the employment of a filter membrane for water analysis, while soil samples were analyzed directly without any pretreatment. The solvent-free approach, straightforward operation, and high sensitivity of the proposed method show great potential for the analysis of MNPs in different environmental samples.
Collapse
Affiliation(s)
- Shengrui Xu
- Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, Collaborative Innovation Center of Henan Province for Green Manufacturing of Fine Chemicals, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, P. R. China
| | - Huimin Li
- Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, Collaborative Innovation Center of Henan Province for Green Manufacturing of Fine Chemicals, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, P. R. China
| | - Li Xiao
- Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huai River Water Environmental Pollution and Control, Ministry of Education, School of Environment, Henan Normal University, Xinxiang 453007, P. R. China
| | - Miaomiao Wang
- Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, Collaborative Innovation Center of Henan Province for Green Manufacturing of Fine Chemicals, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, P. R. China
| | - Suling Feng
- Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, Collaborative Innovation Center of Henan Province for Green Manufacturing of Fine Chemicals, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang 453007, P. R. China
| | - Jing Fan
- Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and Huai River Water Environmental Pollution and Control, Ministry of Education, School of Environment, Henan Normal University, Xinxiang 453007, P. R. China
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
6
|
Olkowicz M, Ramadan K, Rosales-Solano H, Yu M, Wang A, Cypel M, Pawliszyn J. Mapping the metabolic responses to oxaliplatin-based chemotherapy with in vivo spatiotemporal metabolomics. J Pharm Anal 2024; 14:196-210. [PMID: 38464782 PMCID: PMC10921245 DOI: 10.1016/j.jpha.2023.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 07/14/2023] [Accepted: 08/07/2023] [Indexed: 03/12/2024] Open
Abstract
Adjuvant chemotherapy improves the survival outlook for patients undergoing operations for lung metastases caused by colorectal cancer (CRC). However, a multidisciplinary approach that evaluates several factors related to patient and tumor characteristics is necessary for managing chemotherapy treatment in metastatic CRC patients with lung disease, as such factors dictate the timing and drug regimen, which may affect treatment response and prognosis. In this study, we explore the potential of spatial metabolomics for evaluating metabolic phenotypes and therapy outcomes during the local delivery of the anticancer drug, oxaliplatin, to the lung. 12 male Yorkshire pigs underwent a 3 h left lung in vivo lung perfusion (IVLP) with various doses of oxaliplatin (7.5, 10, 20, 40, and 80 mg/L), which were administered to the perfusion circuit reservoir as a bolus. Biocompatible solid-phase microextraction (SPME) microprobes were combined with global metabolite profiling to obtain spatiotemporal information about the activity of the drug, determine toxic doses that exceed therapeutic efficacy, and conduct a mechanistic exploration of associated lung injury. Mild and subclinical lung injury was observed at 40 mg/L of oxaliplatin, and significant compromise of the hemodynamic lung function was found at 80 mg/L. This result was associated with massive alterations in metabolic patterns of lung tissue and perfusate, resulting in a total of 139 discriminant compounds. Uncontrolled inflammatory response, abnormalities in energy metabolism, and mitochondrial dysfunction next to accelerated kynurenine and aldosterone production were recognized as distinct features of dysregulated metabolipidome. Spatial pharmacometabolomics may be a promising tool for identifying pathological responses to chemotherapy.
Collapse
Affiliation(s)
- Mariola Olkowicz
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- Jagiellonian Centre for Experimental Therapeutics (JCET), Jagiellonian University, Krakow, Poland
| | - Khaled Ramadan
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
| | | | - Miao Yu
- The Jackson Laboratory, JAX Genomic Medicine, Farmington, CT, USA
| | - Aizhou Wang
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
| | - Marcelo Cypel
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, University Health Network, University of Toronto, Toronto Lung Transplant Program, Toronto, ON, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
7
|
Nazdrajić E, Rickert DA, Pawliszyn J. Rapid Analysis of Fentanyl and Fentanyl Analogues from Whole Blood Using SPME Coupled to the Microfluidic Open Interface. Anal Chem 2024; 96:821-827. [PMID: 38158586 DOI: 10.1021/acs.analchem.3c04354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Fentanyl and its analogues are potent opioids that pose a significant threat to society. Over the last several years, considerable focus has been on the concerning trend of increasing fentanyl usage among drug users. Fentanyl analogues are mainly synthesized to evade analytical detection or increase their potency; thus, very low concentrations are sufficient to achieve a therapeutic effect. In an effort to help combat the synthetic opioid epidemic, developing targeted mass spectrometric methods for quantifying fentanyl and its analogues at ultralow concentrations is incredibly important. Most methods used to analyze fentanyl and its analogues from whole blood require manual sample preparation protocols (solid-phase extraction or liquid-liquid extraction), followed by chromatographic separation and mass spectrometric detection. The main disadvantages of these methods are the tedious sample preparation workflows, resulting in lengthy analysis times. To mitigate these issues, we present a targeted method capable of analyzing 96 samples containing fentanyl, several fentanyl analogues, and a common fentanyl (analogue) precursor simultaneously in 2.4 min per sample. This is possible by using a high-throughput solid phase microextraction workflow on the Concept96 autosampler followed by manual coupling of solid-phase microextraction fibers to the microfluidic open interface for tandem mass spectrometry analysis. Our quantitative method is capable of extremely sensitive analysis, with limits of quantification ranging from 0.002 to 0.031 ng mL-1 and linearity ranging from 0.010 to 25.0 ng mL-1. The method shows very good reproducibility (1-18%), accuracy (81-100%) of calibration and validation points, and good interday reproducibility (6-15%).
Collapse
Affiliation(s)
- Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo N2L 3G1, ON, Canada
| | - Daniel A Rickert
- Department of Chemistry, University of Waterloo, Waterloo N2L 3G1, ON, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo N2L 3G1, ON, Canada
| |
Collapse
|
8
|
Zhou W, Hu K, Wang Y, Jiang RW, Pawliszyn J. Embedding Mixed Sorbents in Binder: Solid-Phase Microextraction Coating with Wide Extraction Coverage and Its Application in Environmental Water Analysis. Environ Sci Technol 2024; 58:771-779. [PMID: 38127806 DOI: 10.1021/acs.est.3c07244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Solid-phase microextraction (SPME) is a simple and highly effective sample-preparation technique for water analysis. However, the extraction coverage of a given SPME device with a specific coating can be an issue when analyzing multiple environmental contaminants. Therefore, instead of synthesizing one sorbent material with dual or multiple functions, we investigated a new strategy of preparing SPME blades using a homogeneous slurry made by mixing three different sorbent particles─namely, hydrophobic/lipophilic balanced (HLB), HLB-weak cationic exchange (HLB-WCX), and HLB-weak anionic exchange (HLB-WAX)─with a polyacrylonitrile (PAN) binder. The developed coating is matrix compatible, as the binder functions not only as a glue for immobilizing the sorbent particles but also as a porous filter, which only allows small molecules to enter the pores and interact with the particles, thus avoiding contamination from large elements. The results confirmed that the proposed mixed-coating SPME device provides good extraction performance for polar and nonpolar as well as positively and negatively charged compounds. Based on this device, three comprehensive analytical methodologies─high-throughput SPME-LC-MS/MS (for the quantitative analysis of targeted drugs of abuse and artificial sweeteners), in-bottle SPME-LC-high resolution MS (HRMS) (for the untargeted screening of organic contaminants), and on-site drone sampling SPME-LC-HRMS (for on-site sampling and untargeted screening)─were developed for use in environmental water analysis. The resultant data confirm that the proposed strategies enable comprehensive water quality assessment by using a single SPME device.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Kai Hu
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
- Academy of Chinese Medical Sciences, Henan University of Chinese Medicine, Zhengzhou, 450046, China
| | - Yuanpeng Wang
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Runshan Will Jiang
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
9
|
Dincel D, Zeinali S, Pawliszyn J. Determination of free concentration of endocannabinoids in brain tissue. J Pharm Biomed Anal 2023; 235:115624. [PMID: 37595355 DOI: 10.1016/j.jpba.2023.115624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 07/23/2023] [Accepted: 07/31/2023] [Indexed: 08/20/2023]
Abstract
The release of metabolites from their bound to free forms is the main regulatory path in living species. Therefore, the ability to determine the free concentrations of small molecules is highly critical in many biological samples. The main challenges in achieving this task are the interferences inherent to complex matrices and the ability to distinguish between the free and total concentrations. This paper presents a non-invasive microextraction method that enables the determination of endocannabinoids in brain tissue. The proposed method is based on two key principles: the availability of the free concentration of endocannabinoids for partitioning to the solid-phase microextraction (SPME) fiber; and negligible depletion enabled by the small volume of extraction phase on the fiber. These features allow the presented SPME method to provide information about the free concentration of analytes without disturbing the binding equilibrium between the analytes and the matrix. The determination of spiked samples with known concentrations enables the percentage of analyte bound to the tissue to be calculated, which can then be applied to calculate the total concentration from the determined free concentration. This manuscript focuses on the determination of the free concentration and tissue binding percentages of endocannabinoids in brain tissue. Significantly, SPME's small size and potential for non-invasive sampling enable its application in live animal subjects with minimal tissue damage.
Collapse
Affiliation(s)
- Demet Dincel
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada; Department of Analytical Chemistry, Faculty of Pharmacy, Bezmialem Vakif University, Fatih, Istanbul 34093, Turkey
| | - Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
10
|
Looby N, Roszkowska A, Yu M, Rios-Gomez G, Pipkin M, Bojko B, Cypel M, Pawliszyn J. In vivo solid phase microextraction for therapeutic monitoring and pharmacometabolomic fingerprinting of lung during in vivo lung perfusion of FOLFOX. J Pharm Anal 2023; 13:1195-1204. [PMID: 38024854 PMCID: PMC10657970 DOI: 10.1016/j.jpha.2023.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 04/04/2023] [Accepted: 04/08/2023] [Indexed: 12/01/2023] Open
Abstract
In vivo lung perfusion (IVLP) is a novel isolated lung technique developed to enable the local, in situ administration of high-dose chemotherapy to treat metastatic lung cancer. Combination therapy using folinic acid (FOL), 5-fluorouracil (F), and oxaliplatin (OX) (FOLFOX) is routinely employed to treat several types of solid tumours in various tissues. However, F is characterized by large interpatient variability with respect to plasma concentration, which necessitates close monitoring during treatments using of this compound. Since plasma drug concentrations often do not reflect tissue drug concentrations, it is essential to utilize sample-preparation methods specifically suited to monitoring drug levels in target organs. In this work, in vivo solid-phase microextraction (in vivo SPME) is proposed as an effective tool for quantitative therapeutic drug monitoring of FOLFOX in porcine lungs during pre-clinical IVLP and intravenous (IV) trials. The concomitant extraction of other endogenous and exogenous small molecules from the lung and their detection via liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) enabled an assessment of FOLFOX's impact on the metabolomic profile of the lung and revealed the metabolic pathways associated with the route of administration (IVLP vs. IV) and the therapy itself. This study also shows that the immediate instrumental analysis of metabolomic samples is ideal, as long-term storage at -80 °C results in changes in the metabolite content in the sample extracts.
Collapse
Affiliation(s)
- Nikita Looby
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Anna Roszkowska
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Department of Pharmaceutical Chemistry, Medical University of Gdansk, 80-416, Gdansk, Poland
| | - Miao Yu
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - German Rios-Gomez
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Mauricio Pipkin
- Division of Thoracic Surgery, University Health Network, TGH, 200 Elizabeth St, Toronto, ON, M5G 2C4, Canada
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 85-089, Bydgoszcz, Poland
| | - Marcelo Cypel
- Division of Thoracic Surgery, University Health Network, TGH, 200 Elizabeth St, Toronto, ON, M5G 2C4, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
11
|
Murtada K, Nazdrajić E, Pawliszyn J. Performance Evaluation of Extraction Coatings with Different Sorbent Particles and Binder Composition. Anal Chem 2023; 95:12745-12753. [PMID: 37584189 DOI: 10.1021/acs.analchem.3c01462] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2023]
Abstract
Binders are critical components used in the preparation of a range of extraction devices, including solid-phase microextraction (SPME) devices. While the main role of a binder is to affix the sorbent particles to the selected support, it is critical to select the optimal binder to ensure that it does not negatively impact the coating's particle sorption capability. This work presents the first comprehensive investigation of the interactions between binders and solid sorbent particles as these interactions can significantly impact the performance of the coating. Specifically, the findings presented herein provide a better understanding of the extraction mechanisms of composite coatings and new rules for predicting the particle adhesion forces and binder distribution in the coating. The influence of binder chemistry on coating performance is investigated by examining a selection of the most used binders, namely, polydimethylsiloxane (PDMS), polyacrylonitrile (PAN), poly(vinylidene difluoride) (PVDF), polytetrafluoroethylene amorphous fluoroplastics (PTFE AF 2400), and polybenzimidazole (PBI). The solid particles (e.g., hydrophilic-lipophilic balanced (HLB) and C18) used in this work were selected for their ability to provide optimal extraction coverage for a broad range of analytes. The results show that PDMS does not change the properties of the solid particles and that the binder occupies a negligible volume due to shrinking after polymerization, resulting in the solid particles making up most of the coating volume. Hence, the coating sorption characteristics correspond closely to the properties of the selected solid particles. On the other hand, the results also showed that PTFE AF 2400 can interact with the active surface of the sorbent, leading to the deactivation of the sorbent particles. Therefore, the extraction performance and permeability coefficients decrease as the size of the penetrant increases, indicating a rigid porous structure. The results of this study can aid in the optimization of SPME devices as they provide reference values that can be used to determine the optimal binder and the sorbent affinity for the targeted compounds. Finally, the present work also provides the broader scientific community with a strategy for investigating the properties of sorbent particle/binder structures and defines the characteristics of a good coating/membrane by analyzing all parameters such as kinetics, thermodynamic equilibria, and morphology.
Collapse
Affiliation(s)
- Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
12
|
Murtada K, Nazdrajić E, Pawliszyn J. Polybenzimidazole: a novel, fluorocarbon-free, SPME sorbent binder with good thermal and solvent resistance properties for GC and LC analysis. Mikrochim Acta 2023; 190:323. [PMID: 37493831 DOI: 10.1007/s00604-023-05889-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 07/06/2023] [Indexed: 07/27/2023]
Abstract
A novel solid-phase microextraction (SPME) coating is presented that uses polybenzimidazole (PBI) as a binder to immobilize micro-size sorbent particles onto a support. An evaluation of the developed binder's thermal and solvent desorption capabilities demonstrated its compatibility with both gas and liquid chromatography (GC and LC). The incorporation of hydrophilic-lipophilic balanced (HLB) particles provided optimal extraction coverage for an array of chemically diverse analytes possessing a range of hydrophobicities and molecular weights. The developed binder's performance was assessed by comparing it to a selection of binders commonly used in the literature, including polydimethylsiloxane (PDMS) and polyacrylonitrile (PAN), as well as the more recently developed polyvinylidene fluoride (PVDF) and polytetrafluoroethylene amorphous fluoroplastic (PTFE AF 2400). The results revealed that PBI provides better performance compared to PVDF and PTFE AF 2400 in terms of its environmental impact, while also being convenient for use in coating preparation and offering good matrix compatibility. The thermal analysis revealed that PBI exhibited more than 93% weight retention at 550 °C, which is superior to PVDF's 80.07% weight retention at 393.78 °C. To the best of our knowledge, this work is the first to use PBI as a particle binder in SPME coatings. The PBI coating maintained high extraction efficiencies under extreme conditions with pH values of 3 and 12. The performance of PBI in combination with HLB was assessed by employing it to extract several drugs of abuse and McReynolds compounds for LC and GC analysis, respectively. The results indicated that PBI performs similarly to PAN for LC but is outperformed by PDMS in GC applications with respect to extraction and desorption kinetics. Nonetheless, the thermal and solvent desorption results indicated that PBI can be used for both applications, as it remains stable at temperatures over 350 °C and is stable when solvent desorption is applied.
Collapse
Affiliation(s)
- Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
13
|
Zhou W, Wieczorek MN, Pawliszyn J. High throughput and automated solid-phase microextraction and determination by liquid chromatography-mass spectrometry for the analysis of mycotoxins in beer. Food Chem 2023; 426:136557. [PMID: 37311300 DOI: 10.1016/j.foodchem.2023.136557] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/28/2023] [Accepted: 06/04/2023] [Indexed: 06/15/2023]
Abstract
There is high demand for rapid screening of toxics in food analysis. In this study, a new high-throughput and automated solid-phase microextraction (SPME) system was employed for the sample preparation of mycotoxins in beers. Matrix compatible SPME blades with thin coating layer were used, which significantly decreased the matrix effects in beer samples (≤ 12%). This SPME system allows 96 samples to be processed automatically and simultaneously with average preparation time of 57 s per sample. After sample preparation, the 96-well plate with desorption solution was sealed with a thin film and put into the LC-MS sampler for analysis via positive/negative ESI switching mode. The results also showed good sensitivity (limits of detection between 0.02 and 3 ng/mL) with R2≥ 0.9971, reproducibility (intra- and inter-day ≤ 8% and ≤ 13%, respectively), and accuracy (recoveries between 79% and 121%).
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Martyna N Wieczorek
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada; Faculty of Food Science and Nutrition, Poznań University of Life Sciences, Poznań, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
| |
Collapse
|
14
|
Abstract
A solid-phase microextraction (SPME) pin device with a biocompatible coating on the tip was developed for direct coupling to mass spectrometry (MS) via a vertical dipping-and-spray strategy using an automated probe electrospray ionization (PESI) interface. The developed method provides superior sensitivity compared to standard PESI-MS due to the enrichment effects of SPME and the significant increase in the volume of sample and/or solvent collected during dipping due to the SPME pin's notably larger size. The tips of the SPME pins were coated with a biocompatible coating consisting of small sorbent particles embedded into a polyacrylonitrile (PAN) binder. This coating enables the extraction of small molecules, while preventing larger molecules such as tissue fragments, proteins, and cell matter from coming into the sorbent. The developed SPME pin-PESI-MS method also features much lower matrix effects compared to PESI-MS for the analysis of complex biology samples. When applied for the analysis of 8 drugs of abuse in urine samples, the SPME pin-PESI-MS method provided good linearity (R2 ≥ 0.9997), high sensitivity with limits of detection between 0.003 to 0.03 ng/mL, and good reproducibility with RSD% ≤ 6%. The vertical design of the SPME-PESI-MS direct-coupling interface allows the potential fully automation of the system using a conventional autosampler.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
15
|
Zhou W, Nazdrajić E, Pawliszyn J. High-Throughput and Rapid Screening of Drugs of Abuse in Saliva by Multi-Segment Injection Using Solid-Phase Microextraction-Automated Microfluidic Open Interface-Mass Spectrometry. Anal Chem 2023; 95:6367-6373. [PMID: 37021600 PMCID: PMC10848236 DOI: 10.1021/acs.analchem.2c05782] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
There is great demand for analytical methods capable of providing high-throughput and rapid screening, especially for anti-doping and clinical point-of-care applications. In this work, automated microfluidic open interface-mass spectrometry (MOI-MS) was used for coupling with high-throughput, automated solid-phase microextraction (SPME) to achieve this objective. The design of the MOI-MS interface provides a continuous and stable electrospray fluid flow to the MS without introducing any bubble, a feature that we exploit to introduce the concept of multi-segment injection for the determination of multiple samples in a single MS run. By eliminating the need to start a new MS run between sample assays, the developed approach provides significantly simplified protocols controlled by programmed software and increased reproducibility. Furthermore, the biocompatible SPME device, which utilizes coating consisting of hydrophilic-lipophilic balanced particles embedded in a polyacrylonitrile (PAN) binder, can be directly used for biological sample analysis, as the PAN acts as both a binder and a matrix-compatible barrier, thus enabling the enrichment of small molecules while eliminating interferences associated with the presence of interfering macromolecules. The above design was employed to develop a fast, quantitative method capable of analyzing drugs of abuse in saliva samples in as little as 75 s per sample. The findings indicate that the developed method provides good analytical performance, with limits of detection ranging between 0.05 and 5 ng/mL for analysis of 16 drugs of abuse, good calibration linear correlation coefficients (R2 ≥ 0.9957), accuracy between 81 and 120%, and excellent precision (RSD% < 13%). Finally, a proof-of-concept experiment was performed to demonstrate the method's suitability for real-time analysis in anti-doping applications.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
16
|
Wang Y, Zhou W, Pawliszyn J. Sequential Solid-Phase Microextraction with Biocompatible Coating Materials to Address Displacement Effects in the Quantitative Analysis. Anal Chem 2023; 95:6718-6724. [PMID: 37039451 DOI: 10.1021/acs.analchem.3c00508] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
Abstract
Solid-phase microextraction (SPME) is a simple and effective sample-preparation technique for the analysis of complex samples. However, sample matrices containing high concentrations of nonpolar substances or spiked analytes in free form can cause swelling, saturation, and/or competition phenomena in the coating material. This results in a displacement effect wherein polar analytes with low affinities for the solid coating material are displaced by nonpolar substances in the matrix or spiked analytes with a high affinity. Therefore, the quantitative analysis of polar analytes can be challenging, as the displacement effect causes non-linearity in the calibration curves. This paper presents a comprehensive investigation of the conditions under which the displacement effect occurs and how it influences the quantitative analysis of polar analytes. To remedy this issue, a sequential SPME strategy using two SPME blades with different selectivities is applied. SPME blades offer a large surface area and coating volume─and thus, greater extraction capacity─which may mitigate the displacement effect. In addition, the biocompatible coatings on the SPME blades are comprised of small amounts of sorbent particles embedded by a polyacrylonitrile (PAN) binder, which allows them to be directly immersed into complex matrixes such as biological and food samples, as the PAN acts as a barrier that prevents the adsorption of large macromolecules (e.g., cells and proteins). As such, a C18/PAN-coated blade was applied for the first extraction step, which significantly decreased the concentrations of nonpolar compounds in the sample. In the second step, a hydrophilic-lipophilic balanced (HLB)/PAN-coated blade was employed to extract the polar analytes and any remaining nonpolar analytes. The proposed sequential SPME strategy successfully enabled the quantitative determination of polar and nonpolar drugs of abuse with log P values ranging from 0.16 to 4.98 in biological matrices while also providing good linearities.
Collapse
Affiliation(s)
- Yuanpeng Wang
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Food Science College, Shenyang Agricultural University, Shenyang 110866, China
| | - Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
17
|
Nazdrajić E, Murtada K, Rickert DA, Pawliszyn J. Coupling of Solid-Phase Microextraction Directly to Mass Spectrometry via an Improved Microfluidic Open Interface to Facilitate High-Throughput Determinations. J Am Soc Mass Spectrom 2023. [PMID: 37004172 DOI: 10.1021/jasms.2c00380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Mass spectrometry analysis can be performed by introducing samples directly to mass spectrometry, allowing the increase of the analysis throughput; however, some disadvantages of direct-to-mass spectrometry analysis include susceptibility to matrix effects and risk of instrument contamination from inadequate sample preparation. Solid-phase microextraction is one of the most suitable sample preparation methods for direct-to-mass spectrometry analysis, as it offers matrix-compatible coatings which ensure analyte enrichment with minimal or no interference from matrix. One of the ways solid-phase microextraction can be coupled directly to mass spectrometry is via a microfluidic open interface. This manuscript reports improvements made to the initial microfluidic open interface design, where the system components have been simplified to mostly commercially available materials. In addition, the analysis of samples has been automated by implementing software that fully controls the analysis workflow, where the washing procedure is optimized to completely reduce the carryover. Herein, the extraction and desorption time profiles from thin and thick SPME devices was studied where the overall workflow consisted of high-throughput sample preparation of 1.3 min per 96 samples and <1 min per sample instrumental analysis.
Collapse
Affiliation(s)
- Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Daniel A Rickert
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
18
|
Zhou W, Wieczorek MN, Jiang RW, Pawliszyn J. Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma. J Pharm Anal 2023; 13:216-222. [PMID: 36908852 PMCID: PMC9999297 DOI: 10.1016/j.jpha.2022.10.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/12/2022] [Accepted: 10/28/2022] [Indexed: 11/11/2022] Open
Abstract
The direct coupling of solid-phase microextraction (SPME) to mass spectrometry (MS) (SPME-MS) has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma. In recent years, our lab has developed three novel SPME-MS techniques: SPME-microfluidic open interface-MS (SPME-MOI-MS), coated blade spray-MS (CBS-MS), and SPME-probe electrospray ionization-MS (SPME-PESI-MS). The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing. However, all these three techniques utilize different SPME geometries and were tested with different MS instruments. Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application. This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers, CBS blades, and SPME-PESI probes and SPME-liquid chromatography-MS (SPME-LC-MS) for the analysis of drugs of abuse using the same MS instrument. Furthermore, for the first time, we developed different desorption chambers for MOI-MS for coupling with SPME fibers, CBS blades, and SPME-PESI probes, thus illustrating the universality of this approach. In total, eight analytical methods were developed, with the experimental data showing that all the SPME-based methods provided good analytical performance with R 2 of linearities larger than 0.9925, accuracies between 81% and 118%, and good precision with an RSD% ≤ 13%.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Martyna N Wieczorek
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.,Faculty of Food Science and Nutrition, Poznań University of Life Sciences, Poznań, Poland
| | - Runshan Will Jiang
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
19
|
Dincel D, Rosales-Solano H, Zeinali S, Pawliszyn J. Standard Water Generating Vials for Lipophilic Compounds. Anal Chem 2023; 95:820-826. [PMID: 36546835 PMCID: PMC10848237 DOI: 10.1021/acs.analchem.2c02993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The study of non-polar compounds in aqueous environments has always been challenging due to their poor solubility in aqueous media. The low affinity of non-polar compounds toward polar solutions facilitates their attachment to glassware, which results in unstable sample concentrations. To address this challenge, and to enable the preparation of a stable mixture of hydrophobic compounds in an aquatic environment, we introduce an in-vial standard water generating system consisting of a vial containing appropriate aqueous solution and a polydimethylsiloxane thin film spiked with target compounds. In this system, a solution with a stable analyte concentration is attained once equilibrium between the thin-film and aqueous solution has been achieved. The developed standard water system was studied using endocannabinoids and phospholipids as model hydrophobic compounds of biological importance, with results indicating that the concentration of hydrophobic compounds in water can remain stable over multiple days. The results also showed that analytes released from the thin film can compensate for analyte loss due to extractions with solid-phase microextraction fibers, thereby re-establishing equilibrium. Thus, the vial is suitable for the repeatable generation of non-polar standards for routine analysis and quality control. The results of this work show that the developed system is stable and reproducible and therefore appropriate for studies requiring the measurement of free concentrations and accurate quantification.
Collapse
Affiliation(s)
- Demet Dincel
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Department of Analytical Chemistry, Faculty of Pharmacy, Bezmialem Vakif University, Fatih, Istanbul 34093, Turkey
| | | | - Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
20
|
Jiang RW, Jaroch K, Pawliszyn J. Solid-phase microextraction of endogenous metabolites from intact tissue validated using a Biocrates standard reference method kit. J Pharm Anal 2023; 13:55-62. [PMID: 36816540 PMCID: PMC9937786 DOI: 10.1016/j.jpha.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 09/22/2022] [Accepted: 09/22/2022] [Indexed: 11/06/2022] Open
Abstract
Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed. Currently, conventional sample preparation methods often involve tissue biopsy and/or homogenization, which disrupts the endogenous metabolome. In this study, solid-phase microextraction (SPME) fibers were used to monitor changes in endogenous compounds in homogenized and intact ovine lung tissue. Following SPME, a Biocrates AbsoluteIDQ assay was applied to make a downstream targeted metabolomics analysis and confirm the advantages of in vivo SPME metabolomics. The AbsoluteIDQ kit enabled the targeted analysis of over 100 metabolites via solid-liquid extraction and SPME. Statistical analysis revealed significant differences between conventional liquid extractions from homogenized tissue and SPME results for both homogenized and intact tissue samples. In addition, principal component analysis revealed separated clustering among all the three sample groups, indicating changes in the metabolome due to tissue homogenization and the chosen sample preparation method. Furthermore, clear differences in free metabolites were observed when extractions were performed on the intact and homogenized tissue using identical SPME procedures. Specifically, a direct comparison showed that 47 statistically distinct metabolites were detected between the homogenized and intact lung tissue samples (P < 0.05) using mixed-mode SPME fibers. These changes were probably due to the disruptive homogenization of the tissue. This study's findings highlight both the importance of sample preparation in tissue-based metabolomics studies and SPME's unique ability to perform minimally invasive extractions without tissue biopsy or homogenization while providing broad metabolite coverage.
Collapse
Affiliation(s)
- Runshan Will Jiang
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada
| | - Karol Jaroch
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada,Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz, 85-089, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada,Corresponding author.
| |
Collapse
|
21
|
Rickert D, Gómez-Ríos GA, Singh V, Pawliszyn J. Understanding the effect of spatial positioning of coated blade spray devices relative to the mass spectrometry inlet on different instrument platforms and its application to quantitative analysis of fentanyl and related analogs. Rapid Commun Mass Spectrom 2022; 36:e9388. [PMID: 36039809 DOI: 10.1002/rcm.9388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/29/2022] [Accepted: 08/29/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE We evaluated the effect that the spatial positioning of coated-blade spray (CBS) devices with respect to the mass spectrometry (MS) inlet has when coupling to diverse MS platforms (i.e., triple quadrupole, linear ion trap and time of flight). Furthermore, as a proof of concept, we evaluated CBS-MS as a tool for quantitation of fentanyl and four analogues on said instruments. METHODS Custom-made MS interfaces were made to accurately position the blade in front of the MS inlet. CBS devices, coated with hydrophilic-lipophilic balanced particles, were used for both the optimization of the CBS position and the quantitation of fentanyl and analogues in urine and plasma samples on all instruments. RESULTS The SCIEX triple quadrupole instrument was the most sensitive to the position of the blade due to the presence of a curtain gas flowing laminarly out of the MS inlet. After optimization, the analytical capabilities of CBS on each instrument were assessed and the results obtained on both SCIEX and Waters platforms matched the performance obtained using a more advanced instrument by ThermoFisher Scientific. Furthermore, excellent figures of merit were attained for the quantitation of fentanyl and analogues on both triple quadrupole and linear ion trap platforms. CONCLUSIONS We demonstrated that optimization of MS parameters on different instrument vendors and front ends, such as the position of the CBS tip regarding the MS inlet, is vital to exploit the full quantitative potential of this technology. Application of the technology to screen and quantify fentanyl and analogues showed great potential when considering its coupling with portable mass spectrometers for therapeutic drug monitoring and point-of-care applications.
Collapse
Affiliation(s)
- Daniel Rickert
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| | | | - Varoon Singh
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
22
|
Tong YJ, Yu LD, Li N, Shen M, Peng X, Yang H, Ye YX, Zhu F, Pawliszyn J, Xu J, Ouyang G. Novel lanthanide nanoparticle frameworks for highly efficient photoluminescence and hypersensitive detection. Chem Sci 2022; 13:13948-13955. [PMID: 36544738 PMCID: PMC9710216 DOI: 10.1039/d2sc05915k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 11/09/2022] [Indexed: 11/19/2022] Open
Abstract
Despite the excellent luminescent properties of lanthanide clusters (LnCs), their suprastructures that inherit their characteristic luminescent properties are scarcely reported. Herein, novel and highly luminescent suprastructures are synthesized via a two-step assembly method to incorporate LnCs in covalent organic frameworks (COFs). COFs are pre-synthesized and decorated with rigid anchoring groups on their nanochannel walls, which provide one-dimensional confined spaces for the subsequent in situ assembly of luminescent LnCs. The confined LnCs are termed nanoparticles (NPs) to distinguish them from the pure LnCs. Secondary micropores with predictable sizes are successfully formed between the walls of the nanochannels and the orderly aligned NPs therein. By using a small organic ligand that can efficiently sensitize Ln(iii) cations in the assembly processes, the obtained composites show high quantum yields above 20%. The fluorescence can even be effectively maintained across nine pH units. The secondary micropores further enable the unambiguous discrimination of six methinehalides and ultrasensitive detection of uranyl ions. This study provides a new type of luminescent material that has potential for sensing and light emitting.
Collapse
Affiliation(s)
- Yuan-Jun Tong
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Lu-Dan Yu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Nan Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Minhui Shen
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Xiaoru Peng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Huangsheng Yang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Yu-Xin Ye
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Janusz Pawliszyn
- Department of Chemistry, University of WaterlooWaterlooOntario N2L3G1Cananda
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen UniversityGuangzhouGuangdong 510006China,Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou UniversityKexue Avenue 100Zhengzhou 450001China,Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangdong Academy of Sciences100 Xianlie Middle RoadGuangzhou 510070China
| |
Collapse
|
23
|
Zhou W, Pawliszyn J. Coated Blade Spray with a Barrier: Improving Negative Electrospray Ionization and Sample Preparation. Anal Chem 2022; 94:15879-15886. [DOI: 10.1021/acs.analchem.2c04003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, OntarioN2L 3G1, Canada
| |
Collapse
|
24
|
Olkowicz M, Rosales-Solano H, Ramadan K, Wang A, Cypel M, Pawliszyn J. The metabolic fate of oxaliplatin in the biological milieu investigated during in vivo lung perfusion using a unique miniaturized sampling approach based on solid-phase microextraction coupled with liquid chromatography-mass spectrometry. Front Cell Dev Biol 2022; 10:928152. [PMID: 36092704 PMCID: PMC9453651 DOI: 10.3389/fcell.2022.928152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 07/04/2022] [Indexed: 11/13/2022] Open
Abstract
Adjuvant chemotherapy after pulmonary metastasectomy for colorectal cancer may reduce recurrence and improve survival rates; however, the benefits of this treatment are limited by the significant side effects that accompany it. The development of a novel in vivo lung perfusion (IVLP) platform would permit the localized delivery of high doses of chemotherapeutic drugs to target residual micrometastatic disease. Nonetheless, it is critical to continuously monitor the levels of such drugs during IVLP administration, as lung injury can occur if tissue concentrations are not maintained within the therapeutic window. This paper presents a simple chemical-biopsy approach based on sampling with a small nitinol wire coated with a sorbent of biocompatible morphology and evaluates its applicability for the near-real-time in vivo determination of oxaliplatin (OxPt) in a 72-h porcine IVLP survival model. To this end, the pigs underwent a 3-h left lung IVLP with 3 doses of the tested drug (5, 7.5, and 40 mg/L), which were administered to the perfusion circuit reservoir as a bolus after a full perfusion flow had been established. Along with OxPt levels, the biocompatible solid-phase microextraction (SPME) probes were employed to profile other low-molecular-weight compounds to provide spatial and temporal information about the toxicity of chemotherapy or lung injury. The resultant measurements revealed a rather heterogeneous distribution of OxPt (over the course of IVLP) in the two sampled sections of the lung. In most cases, the OxPt concentration in the lung tissue peaked during the second hour of IVLP, with this trend being more evident in the upper section. In turn, OxPt in supernatant samples represented ∼25% of the entire drug after the first hour of perfusion, which may be attributable to the binding of OxPt to albumin, its sequestration into erythrocytes, or its rapid nonenzymatic biotransformation. Additionally, the Bio-SPME probes also facilitated the extraction of various endogenous molecules for the purpose of screening biochemical pathways affected during IVLP (i.e., lipid and amino acid metabolism, steroidogenesis, or purine metabolism). Overall, the results of this study demonstrate that the minimally invasive SPME-based sampling approach presented in this work can serve as (pre)clinical and precise bedside medical tool.
Collapse
Affiliation(s)
- Mariola Olkowicz
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| | | | - Khaled Ramadan
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
| | - Aizhou Wang
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
| | - Marcelo Cypel
- Latner Thoracic Surgery Research Laboratories, Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
- Division of Thoracic Surgery, Department of Surgery, University Health Network, University of Toronto, Toronto Lung Transplant Program, Toronto, ON, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- *Correspondence: Janusz Pawliszyn,
| |
Collapse
|
25
|
Zhou W, Nazdrajić E, Pawliszyn J. Rapid Screening and Quantitation of Drugs of Abuse by Both Positive and Negative Modes via Coated Blade Spray-Mass Spectrometry. J Am Soc Mass Spectrom 2022; 33:1187-1193. [PMID: 35609124 DOI: 10.1021/jasms.2c00040] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Solid-phase microextraction (SPME)-direct mass spectrometry (MS) has proven to be an efficient tool for the rapid screening and quantitation of target compounds at trace levels. However, it is challenging to perform screening using both positive and negative modes in one analytical run without compromising scanning speed and detection sensitivity. To take advantage of the special geometry of a coated blade spray (CBS) blade, which consists of two flat sides coated with the same SPME coating, we developed a CBS-MS method that enables desorption and ionization to be performed in positive ionization mode on one side of a coated blade and negative ionization mode on the other side of the same blade. By simply flipping the blade 180°, MS analysis in both ionization modes on different sides can be completed in 40 s. Combining this approach with an automated Concept 96-blade-based SPME system allowed analysis for one sample in positive and negative modes to be completed in less than 1 min. The workflow was optimized by using a biocompatible polyacrylonitrile as an undercoating layer and a binder of polyacrylonitrile/hydrophilic-lipophilic balance (HLB) particles, which enabled the rapid analysis of 20 drugs of abuse in saliva samples in both positive and negative modes. The proposed method provided low limits of quantification (between 0.005 and 10 ng/mL), with calibration linear correlation coefficients ⩾ 0.9925, accuracy between 72% and 126%, and relative precision < 15% for three validation points.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
26
|
Olkowicz M, Ribeiro RVP, Yu F, Alvarez JS, Xin L, Yu M, Rosales R, Adamson MB, Bissoondath V, Smolenski RT, Billia F, Badiwala MV, Pawliszyn J. Dynamic Metabolic Changes During Prolonged Ex Situ Heart Perfusion Are Associated With Myocardial Functional Decline. Front Immunol 2022; 13:859506. [PMID: 35812438 PMCID: PMC9267769 DOI: 10.3389/fimmu.2022.859506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 05/20/2022] [Indexed: 11/13/2022] Open
Abstract
Ex situ heart perfusion (ESHP) was developed to preserve and evaluate donated hearts in a perfused beating state. However, myocardial function declines during ESHP, which limits the duration of perfusion and the potential to expand the donor pool. In this research, we combine a novel, minimally-invasive sampling approach with comparative global metabolite profiling to evaluate changes in the metabolomic patterns associated with declines in myocardial function during ESHP. Biocompatible solid-phase microextraction (SPME) microprobes serving as chemical biopsy were used to sample heart tissue and perfusate in a translational porcine ESHP model and a small cohort of clinical cases. In addition, six core-needle biopsies of the left ventricular wall were collected to compare the performance of our SPME sampling method against that of traditional tissue-collection. Our state-of-the-art metabolomics platform allowed us to identify a large number of significantly altered metabolites and lipid species that presented comparable profile of alterations to conventional biopsies. However, significant discrepancies in the pool of identified analytes using two sampling methods (SPME vs. biopsy) were also identified concerning mainly compounds susceptible to dynamic biotransformation and most likely being a result of low-invasive nature of SPME. Overall, our results revealed striking metabolic alterations during prolonged 8h-ESHP associated with uncontrolled inflammation not counterbalanced by resolution, endothelial injury, accelerated mitochondrial oxidative stress, the disruption of mitochondrial bioenergetics, and the accumulation of harmful lipid species. In conclusion, the combination of perfusion parameters and metabolomics can uncover various mechanisms of organ injury and recovery, which can help differentiate between donor hearts that are transplantable from those that should be discarded.
Collapse
Affiliation(s)
- Mariola Olkowicz
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- Jagiellonian Centre for Experimental Therapeutics (JCET), Jagiellonian University, Krakow, Poland
| | - Roberto Vanin Pinto Ribeiro
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
- Division of Cardiac Surgery, Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Division of Cardiac Surgery, Department of Surgery, Dalhousie University, Halifax, NS, Canada
| | - Frank Yu
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Juglans Souto Alvarez
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Liming Xin
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Miao Yu
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Roizar Rosales
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Mitchell Brady Adamson
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Ved Bissoondath
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | | | - Filio Billia
- Toronto General Hospital Research Institute (TGHRI), University Health Network, Toronto, ON, Canada
- Ted Roger’s Center for Heart Research, University Health Network, Toronto, ON, Canada
| | - Mitesh Vallabh Badiwala
- Division of Cardiovascular Surgery, Peter Munk Cardiac Center, Toronto General Hospital, University Health Network, Toronto, ON, Canada
- Division of Cardiac Surgery, Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Ted Roger’s Center for Heart Research, University Health Network, Toronto, ON, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- *Correspondence: Janusz Pawliszyn,
| |
Collapse
|
27
|
Tong YJ, Yu LD, Huang Y, Li Y, Li N, Fu Q, Ye YX, Zhu F, Pawliszyn J, Xu J, Ouyang G. High-quality full-color carbon quantum dots synthesized under an unprecedentedly mild condition. iScience 2022; 25:104421. [PMID: 35663030 PMCID: PMC9157185 DOI: 10.1016/j.isci.2022.104421] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 04/25/2022] [Accepted: 05/12/2022] [Indexed: 10/31/2022] Open
Abstract
Carbon quantum dots (CQDs) are highly promising to be applied in light-emitting, chemosensing, and other cutting-edge domains. Herein, we successfully fabricate high-quality full-color CQDs under unprecedentedly low temperature and pressure (85°C, 1.88 bar). Stable and narrow fluorescent emissions ranging from blue to green and red light were realized by simple amine engineering, which were further mixed into white-light CQDs with the absolute photoluminescent quantum yield reaching 19.2%. The average mass yield of the CQDs reached 69.0%. The optical performances demonstrated that the CQDs possessed uniform luminescent centers and dominant radiative decay channels. Component analysis further suggested that dehydrated condensation between carboxyl and amine groups directed the growth of the CQDs. By utilizing the CQDs, full-color light-emitting diodes and logic gate sensors were developed. This study paves an important step for promoting the application of CQDs by providing an energy-efficient, safe, and productive synthetic strategy.
Collapse
Affiliation(s)
- Yuan-Jun Tong
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Lu-Dan Yu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Yanjun Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Yutong Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Nan Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Qi Fu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Yu-Xin Ye
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L3G1, Canada
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong 510275, P. R. China.,Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou University, Kexue Avenue 100, Zhengzhou 450001, China.,Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangdong Academy of Sciences, 100 Xianlie Middle Road, Guangzhou 510070, China
| |
Collapse
|
28
|
Looby N, Roszkowska A, Ali A, Bojko B, Cypel M, Pawliszyn J. Metabolomic fingerprinting of porcine lung tissue during pre-clinical prolonged ex vivo lung perfusion using in vivo SPME coupled with LC-HRMS. J Pharm Anal 2022; 12:590-600. [PMID: 36105172 PMCID: PMC9463496 DOI: 10.1016/j.jpha.2022.06.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 05/28/2022] [Accepted: 06/02/2022] [Indexed: 11/09/2022] Open
Abstract
Normothermic ex vivo lung perfusion (NEVLP) has emerged as a modernized organ preservation technique that allows for detailed assessment of donor lung function prior to transplantation. The main goal of this study was to identify potential biomarkers of lung function and/or injury during a prolonged (19 h) NEVLP procedure using in vivo solid-phase microextraction (SPME) technology followed by liquid chromatography-high resolution mass spectrometry (LC-HRMS). The use of minimally invasive in vivo SPME fibers for repeated sampling of biological tissue permits the monitoring and evaluation of biochemical changes and alterations in the metabolomic profile of the lung. These in vivo SPME fibers were directly introduced into the lung and were also used to extract metabolites (on-site SPME) from fresh perfusate samples collected alongside lung samplings. A subsequent goal of the study was to assess the feasibility of SPME as an in vivo method in metabolomics studies, in comparison to the traditional in-lab metabolomics workflow. Several upregulated biochemical pathways involved in pro- and anti-inflammatory responses, as well as lipid metabolism, were observed during extended lung perfusion, especially between the 11th and 12th hours of the procedure, in both lung and perfusate samples. However, several unstable and/or short-lived metabolites, such as neuroprostanes, have been extracted from lung tissue in vivo using SPME fibers. On-site monitoring of the metabolomic profiles of both lung tissues through in vivo SPME and perfusate samples on site throughout the prolonged NEVLP procedure can be effectively performed using in vivo SPME technology. In vivo SPME monitors metabolic changes in porcine lung during 19-h NEVLP. On-site SPME for perfusate sampling monitors metabolite composition during NEVLP. SPME-LC-HRMS permits identification of potential metabolic markers of lung function. Stored perfusate provides less relevant metabolome information compared to on-site perfusate samples. In vivo SPME of the lung provides more metabolomic information than perfusate sampling.
Collapse
|
29
|
Yu J, Xu XB, Murtada K, Pawliszyn J. Untargeted analysis of microbial metabolites and unsaturated fatty acids in salmon via hydrophilic-lipophilic balanced solid-phase microextraction arrow. Food Chem 2022; 380:132219. [DOI: 10.1016/j.foodchem.2022.132219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 11/15/2022]
|
30
|
Zeinali S, Natalia Wieczorek M, Pawliszyn J. Free versus droplet-bound aroma compounds in sparkling beverages. Food Chem 2022; 378:131985. [PMID: 35032804 DOI: 10.1016/j.foodchem.2021.131985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/16/2021] [Accepted: 12/28/2021] [Indexed: 11/15/2022]
Abstract
The initial experience of a beverage's flavor after opening the bottle is created by a combination of the gas phase and droplet-bound odorants. However, most studies do not consider this combination, and focus on the odor-active components in the liquid or gas phase, separately. To cover this aspect, a filter from pyrolyzed polyacrylonitrile fiber was packed inside thermal desorption unit liner and used for trapping droplet-bound odorants. Additionally, polydimethylsiloxane coated thin-film was applied for extraction of gas-phase aroma. Following trapping/extraction, the devices were desorbed and compounds were separated using GC-MS. The odorants in commercial sparkling beverages were quantified immediately after opening the bottle to mimic real-life conditions of the consumer's experience of the flavor. The reported results provide a more comprehensive understanding of flavor perception in effervescent drinks by considering both gas and droplet phase.
Collapse
Affiliation(s)
- Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | | | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
31
|
Wieczorek MN, Zhou W, Pawliszyn J. Sequential thin film-solid phase microextraction as a new strategy for addressing displacement and saturation effects in food analysis. Food Chem 2022; 389:133038. [PMID: 35483299 DOI: 10.1016/j.foodchem.2022.133038] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 03/07/2022] [Accepted: 04/19/2022] [Indexed: 11/17/2022]
Abstract
Solid-phase microextraction (SPME) is robust, selective, sensitive, and can be automated. However, low extraction phase to sample volume ratio sometimes results in saturation, competition, or swelling phenomena in complex samples. A sequential extraction method using two thin-film SPME (TF-SPME) devices with different selectivities was developed. The sequential application of the thin films provided higher extraction capacities, while avoiding swelling, saturation, and displacement effects, and enabled the quantitative determination of all compounds in the analyzed samples, independent of their polarity and affinity to extraction phases. In the first step, a TF-SPME device with a poly(dimethylsiloxane) (PDMS) coating was used to deplete non-polar and other compounds present at high concentrations in the sample, which are typically associated with the undesirable phenomena. In the second step, a TF-SPME device coated with a combination of hydrophobic/lipophilic balanced (HLB) particles and PDMS (HLB/PDMS) was applied for the direct microextraction of the remaining compounds, including polar compounds left over after the first step. The proposed method resulted in decreased levels of interference and yielded encouraging analytical data for beer samples.
Collapse
Affiliation(s)
- Martyna N Wieczorek
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
| |
Collapse
|
32
|
Huq M, Rosales-Solano H, Pawliszyn J. Investigation of binding of fatty acids to serum albumin to determine free concentrations: Experimental and in-silico approaches. Anal Chim Acta 2022; 1192:339370. [DOI: 10.1016/j.aca.2021.339370] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 12/07/2021] [Accepted: 12/09/2021] [Indexed: 12/17/2022]
|
33
|
Jaroch K, Pawliszyn J. Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches. J Pharm Anal 2022; 12:186-191. [PMID: 35573877 PMCID: PMC9073246 DOI: 10.1016/j.jpha.2021.08.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 07/09/2021] [Accepted: 08/02/2021] [Indexed: 11/24/2022] Open
Abstract
The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition. Herein, a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ionization (coated-PESI) and coated blade spray (CBS) as ambient mass spectrometry approaches for monitoring drug biotransformation. The ability of these methods was investigated for monitoring the dephosphorylation of a prodrug, combretastatin A4 phosphate (CA4P), into its active form, combretastatin A4 (CA4), in a cell culture medium supplemented with fetal bovine serum. The CBS spot analysis was modified to achieve the same extraction efficiency as protein precipitation and obtained results in 7 min. Because coated-PESI performs extraction without consuming any samples, it is the preferred technique in the case of a limited sample volume. Although coated-PESI only extracts small quantities of analytes, it uses the desorption solvent volume of 5-10 pL, resulting in high sensitivity, thus allowing the detection of compounds after only 1 min of extraction. The biotransformation of CA4P into CA4 via phosphatases occurs within the simple matrix, and the proposed sample preparation techniques are suitable for monitoring the biotransformation.
Collapse
Affiliation(s)
- Karol Jaroch
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń Poland, 85090, Bydgoszcz, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, N2L 3G1, Canada
| |
Collapse
|
34
|
Abstract
Solid-phase microextraction (SPME) is a well-established sample-preparation technique for environmental studies. The application of SPME has extended from the headspace extraction of volatile compounds to the capture of active components in living organisms via the direct immersion of SPME probes into the tissue (in vivo SPME). The development of biocompatible coatings and the availability of different calibration approaches enable the in vivo sampling of exogenous and endogenous compounds from the living plants and animals without the need for tissue collection. In addition, new geometries such as thin-film coatings, needle-trap devices, recession needles, coated tips, and blades have increased the sensitivity and robustness of in vivo sampling. In this paper, we detail the fundamentals of in vivo SPME, including the various extraction modes, coating geometries, calibration methods, and data analysis methods that are commonly employed. We also discuss recent applications of in vivo SPME in environmental studies and in the analysis of pollutants in plant and animal tissues, as well as in human saliva, breath, and skin analysis. As we show, in vivo SPME has tremendous potential for the targeted and untargeted screening of small molecules in living organisms for environmental monitoring applications.
Collapse
Affiliation(s)
- Miao Yu
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, New York 10029, United States
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdansk, Gdansk 80-416, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
35
|
Yiantzi E, Murtada K, Terzidis K, Pawliszyn J, Psillakis E. Vacuum-assisted headspace thin-film microextraction: Theoretical formulation and method optimization for the extraction of polycyclic aromatic hydrocarbons from water samples. Anal Chim Acta 2022; 1189:339217. [PMID: 34815047 DOI: 10.1016/j.aca.2021.339217] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/13/2021] [Accepted: 10/23/2021] [Indexed: 11/01/2022]
Abstract
The thin films used in headspace thin-film microextraction (HS-TFME) enable higher sensitivity and superior extraction rates compared to other microextraction approaches, largely due to their greater surface area-to-volume ratio and extraction-phase volume. Nonetheless, analytes exhibiting a low affinity for the headspace and/or large partitioning between the extraction phase and headspace will still require more time to reach equilibrium. In this paper, we detail the development of a new method, termed as vacuum-assisted HS-TFME (Vac-HS-TFME), and we demonstrate how its use of vacuum conditions can accelerate the extraction kinetics of analytes with long equilibration times. The pressure-dependence of the extraction process was formulated and related to improvements in gas-phase diffusivity when lowering the total pressure. Four low-molecular-weight polycyclic aromatic hydrocarbons (PAHs) were used to experimentally verify the improvements in extraction efficiencies enabled by Vac-HS-TFME (vs. HS-TFME). To this end, the effects of temperature and extraction time on Vac-HS-TFME were investigated, with the results being compared to those obtained via regular HS-TFME. Furthermore, the use of a high-capacity sorbent in TFME allowed the positive effects of temperature and vacuum conditions to be combined successfully. Extraction-time profiles constructed at 30 and 50 °C revealed substantial acceleration in the overall extraction kinetics when sampling under vacuum conditions. At 50 °C, all of the analytes extracted via Vac-HS-TFME reached equilibrium within 45 min, whereas only two reached this state under atmospheric pressure. Vac-HS-TFME's analytical performance was evaluated under optimized conditions, and the results were compared to those obtained with regular HS-TFME. The findings revealed that for the two lighter PAHs, the performance of the two methods was similar since they were extracted close or at equilibrium. However, the calibration models for the two heavier PAHs tested here were linear over a wider concentration range (50-10000 ng L-1) when using Vac-HS-TFME, had superior intra-day repeatability (7.4% and 6.7% vs. 11% and 9.3% with regular HS-TFME), and the limits of detection were lower compared to regular HS-TFME (15 and 11 ng L-1 compared to 136 to 100 ng L-1 with regular HS-TFME). Finally, the analysis of spiked wastewater effluent samples showed that the matrix did not affect extraction. The proposed Vac-HS-TFME approach combines the advantages of low-pressure sampling and high-capacity sorbent, and has a great potential for future applications in food, flavour, environmental, and biological analyses.
Collapse
Affiliation(s)
- Evangelia Yiantzi
- Laboratory of Aquatic Chemistry, School of Environmental Engineering, Polytechnioupolis, Technical University of Crete, GR-73100, Chania, Crete, Greece
| | - Khaled Murtada
- Department of Chemistry, University of Waterloo, N2L3G1, Waterloo, Ontario, Canada
| | - Konstantinos Terzidis
- Laboratory of Aquatic Chemistry, School of Environmental Engineering, Polytechnioupolis, Technical University of Crete, GR-73100, Chania, Crete, Greece
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, N2L3G1, Waterloo, Ontario, Canada
| | - Elefteria Psillakis
- Laboratory of Aquatic Chemistry, School of Environmental Engineering, Polytechnioupolis, Technical University of Crete, GR-73100, Chania, Crete, Greece.
| |
Collapse
|
36
|
Kasperkiewicz A, Lendor S, Pawliszyn J. Impact of pesticide formulation excipients and employed analytical approach on relative matrix effects of pesticide determination in strawberries. Talanta 2022; 236:122825. [PMID: 34635215 DOI: 10.1016/j.talanta.2021.122825] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/22/2021] [Accepted: 08/23/2021] [Indexed: 01/29/2023]
Abstract
Relative matrix effects between an ambient mass spectrometric technique known as coated blade spray (CBS) and liquid chromatographic separation approach when applied to multiresidue pesticide analysis in strawberry samples are explored. Acceptable slope relative standard deviations (RSD <15 %) were observed for the 9 compounds under study for both CBS-MS/MS (2.2-12.6 %) and LC-MS/MS (2.8-12.9 %) approaches. The findings signify both the elimination of relative matrix effects with the sample preparation and matrix match calibration with internal standard correction methods employed along with no matrix effect compromise made when using the direct-to-MS approach. Similarly, slopes of pesticides spiked from commercially available formulations (containing one or two pesticides) were found to not differ significantly from slopes generated with multiresidue pesticide standards (containing 24 additional pesticides besides the target 9 analytes) with either technique, highlighting the resistance of the employed methods to the excipients present in pesticide formulations in large amounts.
Collapse
Affiliation(s)
| | - Sofia Lendor
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada.
| |
Collapse
|
37
|
Rosales-Solano H, Galievsky V, Murtada K, Radovanovic PV, Pawliszyn J. Profiling of Unsaturated Lipids by Raman Spectroscopy Directly on Solid-Phase Microextraction Probes. Anal Chem 2021; 94:606-611. [PMID: 34935349 DOI: 10.1021/acs.analchem.1c04054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Lipids play a critical role in cellular signaling, energy storage, and the construction of cellular membranes. In this paper, we propose a novel on-site approach for detecting and differentiating enriched unsaturated lipids based on the direct coupling of SPME probes with Raman spectroscopy. To this end, different SPME particles, namely, hydrophilic-lipophilic balanced (HLB), mixed-mode (C8-SCX), and C18, were embedded in polyacrylonitrile (PAN) and tested for their efficacy as biocompatible coatings. The C18/PAN coating showed less background interference compared to the other sorbent materials during the analysis of unsaturated lipids. In addition, different SPME parameters that influence extraction efficiency, such as extraction temperature, extraction time, and washing solvent, were also investigated. Our results indicate a clear dependence between the Raman band intensity related to the number of double bonds in fatty acids mixture and the number of double bonds in a fatty acid. Our findings further show that Raman spectroscopy is especially useful for the analysis of lipid unsaturation, which is calculated as the ratio of n(C═C)/n(CH2) using the intensities of the Raman bands at 1655/1445 cm-1. Furthermore, the developed protocol reveals great SPME activity and high detection ability for several unsaturated lipids in different complex matrixes, such as cod liver oil. Finally, the applicability of this technology was demonstrated via the characterization of cod liver oil and other vegetable oils. Thus, the proposed SPME-Raman spectroscopy approach has a great future potential in food, environmental, clinical, and biological applications.
Collapse
Affiliation(s)
| | - Victor Galievsky
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| | - Khaled Murtada
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| | - Pavle V Radovanovic
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, N2L 3G1 Waterloo, Ontario, Canada
| |
Collapse
|
38
|
Hassani SA, Lendor S, Neumann A, Sinha Roy K, Banaie Boroujeni K, Hoffman KL, Pawliszyn J, Womelsdorf T. Dose-Dependent Dissociation of Pro-cognitive Effects of Donepezil on Attention and Cognitive Flexibility in Rhesus Monkeys. Biol Psychiatry Glob Open Sci 2021; 3:68-77. [PMID: 36712561 PMCID: PMC9874073 DOI: 10.1016/j.bpsgos.2021.11.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 11/16/2021] [Accepted: 11/22/2021] [Indexed: 02/01/2023] Open
Abstract
Background Donepezil exerts pro-cognitive effects by nonselectively enhancing acetylcholine (ACh) across multiple brain systems. Two brain systems that mediate pro-cognitive effects of attentional control and cognitive flexibility are the prefrontal cortex and the anterior striatum, which have different pharmacokinetic sensitivities to ACh modulation. We speculated that these area-specific ACh profiles lead to distinct optimal dose ranges for donepezil to enhance the cognitive domains of attention and flexible learning. Methods To test for dose-specific effects of donepezil on different cognitive domains, we devised a multitask paradigm for nonhuman primates that assessed attention and cognitive flexibility. The nonhuman primates received either vehicle or variable doses of donepezil before task performance. We measured intracerebral donepezil and its strength in preventing the breakdown of ACh within the prefrontal cortex and anterior striatum using solid phase microextraction neurochemistry. Results The highest administered donepezil dose improved attention and made the subjects more robust against distractor interference, but it did not improve flexible learning. In contrast, only a lower dose range of donepezil improved flexible learning and reduced perseveration, but without distractor-dependent attentional improvement. Neurochemical measurements confirmed a dose-dependent increase of extracellular donepezil and decreases in choline within the prefrontal cortex and the striatum. Conclusions The donepezil dose for maximally improving attention differed from the dose range that enhanced cognitive flexibility despite the availability of the drug in two major brain systems supporting these functions. These results suggest that in our cohort of adult monkeys, donepezil traded improvements in attention for improvements in cognitive flexibility at a given dose range.
Collapse
Affiliation(s)
- Seyed A. Hassani
- Department of Psychology, Vanderbilt University, Nashville, Tennessee
| | - Sofia Lendor
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada
| | - Adam Neumann
- Department of Psychology, Vanderbilt University, Nashville, Tennessee
| | - Kanchan Sinha Roy
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada
| | | | - Kari L. Hoffman
- Department of Psychology, Vanderbilt University, Nashville, Tennessee
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada,Janusz Pawliszyn, Ph.D.
| | - Thilo Womelsdorf
- Department of Psychology, Vanderbilt University, Nashville, Tennessee,Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee,Address correspondence to Thilo Womelsdorf, Ph.D.
| |
Collapse
|
39
|
Geballa-Koukoula A, Gerssen A, Blokland MH, Elliott CT, Pawliszyn J, Nielen MWF. Immuno-Enriched Microspheres - Magnetic Blade Spray-Tandem Mass Spectrometry for Domoic Acid in Mussels. Anal Chem 2021; 93:15736-15743. [PMID: 34726384 PMCID: PMC8637537 DOI: 10.1021/acs.analchem.1c03816] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Paramagnetic microspheres can be used in planar array fluorescence immunoassays for single or multiplex screening of food contaminants. However, no confirmation of the molecular identity is obtained. Coated blade spray (CBS) is a direct ionization mass spectrometry (MS) technique, and when combined with triple quadrupole MS/MS, it allows for rapid confirmation of food contaminants. The lack of chromatography in CBS, though, compromises the specificity of the measurement for unequivocal identification of contaminants, based on the European Union (EU) regulation. Therefore, a rapid and easy-to-use immuno-magnetic blade spray (iMBS) method was developed in which immuno-enriched paramagnetic microspheres replace the coating of CBS. The iMBS-MS/MS method was fully optimized, validated in-house following the EU 2021/808 regulation, and benchmarked against a commercial lateral flow immunoassay (LFIA) for on-site screening of DA. The applicability of iMBS-MS/MS was further demonstrated by analyzing incurred mussel samples. The combination of immunorecognition and MS/MS detection in iMBS-MS/MS enhances the measurement's selectivity, which is demonstrated by the rapid differentiation between the marine toxin domoic acid (DA) and its structural analog kainic acid (KA), which cannot be achieved with the LFIA alone. Interestingly, this first-ever reported iMBS-MS/MS method is generic and can be adapted to include any other immuno-captured food contaminant, provided that monoclonal antibodies are available, thus offering a complementary confirmatory analysis approach to multiplex immunoassay screening methods. Moreover, thanks to its speed of analysis, iMBS-MS/MS can bridge the logistics gap between future large-scale on-site testings using LFIAs and classical time-consuming confirmatory MS analysis performed in official control laboratories.
Collapse
Affiliation(s)
- Ariadni Geballa-Koukoula
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands
| | - Arjen Gerssen
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands
| | - Marco H Blokland
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands
| | - Christopher T Elliott
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, Northern Ireland, U.K
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Michel W F Nielen
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.,Laboratory of Organic Chemistry, Wageningen University, Stippeneng 4, 6708 WE Wageningen, The Netherlands
| |
Collapse
|
40
|
Olkowicz M, Rosales-Solano H, Kulasingam V, Pawliszyn J. SPME-LC/MS-based serum metabolomic phenotyping for distinguishing ovarian cancer histologic subtypes: a pilot study. Sci Rep 2021; 11:22428. [PMID: 34789766 PMCID: PMC8599860 DOI: 10.1038/s41598-021-00802-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 10/15/2021] [Indexed: 12/11/2022] Open
Abstract
Epithelial ovarian cancer (EOC) is the most common cause of death from gynecological cancer. The outcomes of EOC are complicated, as it is often diagnosed late and comprises several heterogenous subtypes. As such, upfront treatment can be highly challenging. Although many significant advances in EOC management have been made over the past several decades, further work must be done to develop early detection tools capable of distinguishing between the various EOC subtypes. In this paper, we present a sophisticated analytical pipeline based on solid-phase microextraction (SPME) and three orthogonal LC/MS acquisition modes that facilitates the comprehensive mapping of a wide range of analytes in serum samples from patients with EOC. PLS-DA multivariate analysis of the metabolomic data was able to provide clear discrimination between all four main EOC subtypes: serous, endometrioid, clear cell, and mucinous carcinomas. The prognostic performance of discriminative metabolites and lipids was confirmed via multivariate receiver operating characteristic (ROC) analysis (AUC value > 88% with 20 features). Further pathway analysis using the top 57 dysregulated metabolic features showed distinct differences in amino acid, lipid, and steroids metabolism among the four EOC subtypes. Thus, metabolomic profiling can serve as a powerful tool for complementing histology in classifying EOC subtypes.
Collapse
Affiliation(s)
- Mariola Olkowicz
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | | | - Vathany Kulasingam
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, M5S 1A8, Canada.
- Division of Clinical Biochemistry, University Health Network, Toronto, ON, M5G 2C4, Canada.
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
41
|
Zeinali S, Pawliszyn J. Determination of Droplet-Bound and Free Gas-Phase Fragrances Using a Filter-Incorporated Needle-Trap Device and Solid-Phase Microextraction Technologies. J Agric Food Chem 2021; 69:13657-13667. [PMID: 34662115 DOI: 10.1021/acs.jafc.1c06006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Some of the fragrance compounds in aerosols tend to remain trapped inside the droplets. The ability to capture these droplets would make it possible to desorb and transfer the analytes dissolved within for determination. In this study, we design a novel filter-incorporated needle-trap device and use it to capture fragrance compounds in droplets as well as the gas phase of seven aerosol spray samples. For comparison, thin-film and solid-phase microextraction were also employed to extract gas-phase-borne fragrances from the same sprays. The results revealed that the filter-incorporated needle-trap device enables the extraction of total concentrations due to its ability to trap fragrance-containing droplets, whereas thin-film and solid-phase microextraction are only able to extract unbound compounds present in the gas phase. In addition, the developed needle-trap device provided acceptable results, proving its applicability for the analysis of aroma in other samples, such as beer and soda.
Collapse
Affiliation(s)
- Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
42
|
Nazdrajić E, Murtada K, Pawliszyn J. The Effect of Sorbent Particles in a Binder on the Mass Transfer Kinetics in Separation Media: In Silico Study and Experimental Verification. Anal Chem 2021; 93:14764-14772. [PMID: 34699167 DOI: 10.1021/acs.analchem.1c03373] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Selecting the optimal binder and the sorbent affinity for selected compounds can cause the composite to behave either as an efficient extraction coating, as a permeable membrane, or as an impermeable barrier. If the compound partitions onto the sorbent with high preference, it becomes stationary and the composite behaves as an impermeable barrier, while appropriately optimized affinity will result in effective permeation. To understand this phenomenon, we utilize solid-phase microextraction to characterize the mass transfer attributes of different separation composites. Our results indicate that for strong sorbents, the extraction rate is primarily controlled by the diffusion in the extraction phase rather than the sample matrix, even if it is relatively thin. Low analyte diffusion is caused by the retarding force generated by the partitioning of analytes into the sorbent, as migration through the composite is driven by the unbound form of the compound in the binder. One of the main contributions of this work is that an understanding of the extraction composite parameters that control mass transfer during extraction enables better optimization of binder/sorbent extraction phase composition for a given application. Another contribution of this work shows how a heterogeneous coating model can be simplified into a homogeneous coating model. The developed models enable an enhanced understanding of mass transfer kinetics, and they provide insight into how to optimize the extraction phase parameters for a given method involving sorbent particles in polymeric media, including membranes and paints, in addition to extraction coatings.
Collapse
Affiliation(s)
- Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
43
|
Nowak PM, Wietecha-Posłuszny R, Woźniakiewicz M, Woźniakiewicz A, Król M, Kozak J, Wieczorek M, Knihnicki P, Paluch J, Telk A, Mermer K, Kochana J, Kościelniak P, Pawliszyn J. A Perspective of the Comprehensive and Objective Assessment of Analytical Methods Including the Greenness and Functionality Criteria: Application to the Determination of Zinc in Aqueous Samples. Front Chem 2021; 9:753399. [PMID: 34722459 PMCID: PMC8551957 DOI: 10.3389/fchem.2021.753399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 09/22/2021] [Indexed: 11/20/2022] Open
Abstract
The recently proposed concept of White Analytical Chemistry (WAC), referring to the Red-Green-Blue color model, combines ecological aspects (green) with functionality (red and blue criteria), presenting the complete method as “white”. However, it is not easy to carry out an overall quantitative evaluation of the analytical method in line with the WAC idea in an objective manner. This paper outlines the perspective of the future development of such a possibility by attempting to answer selected questions about the evaluation process. Based on the study consisting in the evaluation of selected model methods by a group of 12 independent analysts, it was shown how well individual criteria are assessed, whether the variability of assessments by different people is comparable for each criterion, how large it is, and whether averaging the scores from different researchers can help to choose the best method more objectively.
Collapse
Affiliation(s)
- Paweł Mateusz Nowak
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | | | - Michał Woźniakiewicz
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Aneta Woźniakiewicz
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Małgorzata Król
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Joanna Kozak
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Marcin Wieczorek
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Paweł Knihnicki
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Justyna Paluch
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Anna Telk
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Karolina Mermer
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Jolanta Kochana
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Paweł Kościelniak
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
44
|
Abstract
Particles in an aerosol sample contain a portion of the total available analytes. Therefore, particle trapping is required to fully characterize a gaseous sample. Needle-trap devices (NTDs) are highly useful to this end, as they allow sampling and preconcentration of free analytes, as well as the trapping of particles. Packing sorbents into the needle creates a filter that traps solid particles or liquid droplets. However, the particle-trapping efficiency of sorbent-packed NTDs is limited, especially for nanoparticles. To address this issue, an aerogel based on electrospun polyacrylonitrile (PAN) was prepared for trapping small particles to analyze particle-bound analytes. The PAN aerogel filter was fabricated by cutting electrospun PAN fibers and removing the remaining solvent via freeze-drying to obtain a light porous fibrous structure. The PAN aerogel was heated (H-PAN) prior to packing to ensure stability during thermal desorption. The trapping efficiency of the H-PAN-packed NTD was measured using a range of conditions, with high filtration efficiencies (>99%) being obtained in all cases. The mechanical stability of the H-PAN aerogel was tested using multiple extraction/desorption cycles with and without solid sorbent particles, with results indicating high repeatability (n = 94, relative standard deviation (RSD) <6%). The developed NTD was compared to thin-film microextraction with respect to their ability to characterize breath samples obtained with or without face masks; the NTD was able to trap both free and droplet-bound analytes, while thin-film microextraction was only able to extract free analytes, which is fully reflected in concentrations obtained with these two methods.
Collapse
Affiliation(s)
- Shakiba Zeinali
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
45
|
Tong YJ, Yu LD, Li N, Fu Q, Xu K, Wei J, Ye YX, Xu J, Zhu F, Pawliszyn J, Ouyang G. Ratiometric fluorescent probe for the on-site monitoring of coexisted Hg 2+ and F - in sequence. Anal Chim Acta 2021; 1183:338967. [PMID: 34627509 DOI: 10.1016/j.aca.2021.338967] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/05/2021] [Accepted: 08/17/2021] [Indexed: 12/23/2022]
Abstract
The monitoring of mercury and fluoride ions (Hg2+ and F-) has aroused wide concerns owing to the high toxicity of Hg2+ and the duplicitous nature of F- to human health. As far as we known, more than 100 million people in poverty-stricken areas are still at high risk of being over-exposed to Hg2+ and F- via drinking water. Simple and cost-effective luminescent methods are highly promising for on-site water monitoring in rural areas. However, the development of multipurpose luminescent probes that are accurate and sensitive remains challenging. Herein, a new strategy for rationally designing a multipurpose ratiometric probe is present. The obtained probe is consisted of two emission units with energy transfer between them, which exhibit high coordination affinities to the two coexisted toxic targets (Hg2+ and F-), respectively. Thus, two distinct routes for efficiently modulating the energy transfer in the probe are present to trigger the responses to the two targets in sequence. By detecting the shift of the emission color with a smartphone, an on-site water monitoring method is successfully established with the detection limits as low as 2.7 nM for Hg2+ and 1.9 μM for F-. The present study can expend the toolbox for water monitoring in rural regions.
Collapse
Affiliation(s)
- Yuan-Jun Tong
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Lu-Dan Yu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Nan Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Qi Fu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Ke Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jiajun Wei
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Yu-Xin Ye
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China.
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China; Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou University, Kexue Avenue 100, Zhengzhou, 450001, China; Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangdong Academy of Sciences, 100 Xianlie Middle Road, Guangzhou, 510070, China
| |
Collapse
|
46
|
Thirukumaran M, Singh V, Arao Y, Fujito Y, Nishimura M, Ogura T, Pawliszyn J. Solid-phase microextraction- probe electrospray ionization devices for screening and quantitating drugs of abuse in small amounts of biofluids. Talanta 2021; 231:122317. [PMID: 33965011 DOI: 10.1016/j.talanta.2021.122317] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 03/12/2021] [Accepted: 03/13/2021] [Indexed: 02/03/2023]
Abstract
Probe electrospray ionization (PESI) is an ambient ionization mass spectrometry technique (AIMS) that is primarily used in qualitative studies, though researchers have recently combined it with sample preparation for the quantitative analysis of various analytes in biological matrices. This study presents a method that integrates solid-phase microextraction with PESI for direct coupling to a triple quadrupole mass spectrometer, and examines its ability to quantitate drugs of abuse. Intra- and inter-probe reproducibility experiments were conducted to assess the stability and reproducibility of the extraction-phase-coated PESI probes (coating length: 2 mm; coating thickness: 6.5 μm). This research is the first documented instance wherein highly sensitive determinations were successfully attained using these microextraction and micro-desorption techniques in conjunction with small volumes of sample and extraction phase. A mixture consisting of IPA/H2O (1/1 v/v) + 0.1% FA was determined to be the optimal desorption solvent for SPME-PESI-MS/MS, as it facilitated high analyte enrichment in a picolitre of the solvent, which acted at the same time as efficient electrospray media. Furthermore, a method of quantifying drugs of abuse in 30 μL of plasma without matrix modification was also developed. This method had an intra-day accuracy within the 80-120% range for all eight drugs of abuse at concentrations of 3, 30, and 90 pg μL-1; the exception to this result was lorazepam at 30 pg μL-1, which had an intra-day accuracy of 122%. The lower limit of quantification (LLOQ) for fentanyl and nordiazepam was pg μL-1; the LLOQ for buprenorphine, codeine, diazepam, lorazepam, and propranolol was 5 pg μL-1; and the LLOQ of oxazepam was 10 pg μL-1.
Collapse
Affiliation(s)
- Milaan Thirukumaran
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Yohei Arao
- Shimadzu Scientific Instruments, Inc., 7102 Riverwood Drive, Columbia, MD, 21046, USA; Shimadzu Corporation, Kyoto, Japan
| | - Yuka Fujito
- Shimadzu Scientific Instruments, Inc., 7102 Riverwood Drive, Columbia, MD, 21046, USA
| | - Masayuki Nishimura
- Shimadzu Scientific Instruments, Inc., 7102 Riverwood Drive, Columbia, MD, 21046, USA
| | - Tairo Ogura
- Shimadzu Scientific Instruments, Inc., 7102 Riverwood Drive, Columbia, MD, 21046, USA; Shimadzu Corporation, Kyoto, Japan
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
47
|
Roy KS, Nazdrajić E, Shimelis OI, Ross MJ, Chen Y, Cramer H, Pawliszyn J. Optimizing a High-Throughput Solid-Phase Microextraction System to Determine the Plasma Protein Binding of Drugs in Human Plasma. Anal Chem 2021; 93:11061-11065. [PMID: 34353028 DOI: 10.1021/acs.analchem.1c01986] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Plasma protein binding refers to the binding of a drug to plasma proteins after entering the body. The measurement of plasma protein binding is essential during drug development and in clinical practice, as it provides a more detailed understanding of the available free concentration of a drug in the blood, which is in turn critical for pharmacokinetics and pharmacodynamics studies. In addition, the accurate determination of the free concentration of a drug in the blood is also highly important for therapeutic drug monitoring and in personalized medicine. The present study uses C18-coated solid-phase microextraction 96-pin devices to determine the free concentrations of a set of drugs in plasma, as well as the plasma protein binding of drugs with a wide range of physicochemical properties. It should be noted that the extracted amounts used to calculate the binding constants and plasma protein bindings should be measured at respective equilibrium for plasma and phosphate buffer. Therefore, special attention is placed on properly determining the equilibration times required to correctly estimate the free concentrations of drugs in the investigated systems. The plasma protein binding values obtained with the 96-pin devices are consistent with those reported in the literature. The 96-pin device used in this research can be easily coupled with a Concept96 or other automated robotic systems to create an automated plasma protein binding determination protocol that is both more time and labor efficient compared to conventional equilibrium dialysis and ultrafiltration methods.
Collapse
Affiliation(s)
- Kanchan Sinha Roy
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Olga I Shimelis
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - M James Ross
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Yong Chen
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Hugh Cramer
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
48
|
Tong YJ, Yu LD, Huang Y, Fu Q, Li N, Peng S, Ouyang S, Ye YX, Xu J, Zhu F, Pawliszyn J, Ouyang G. Polymer Ligand-Sensitized Lanthanide Metal-Organic Frameworks for an On-Site Analysis of a Radionuclide. Anal Chem 2021; 93:9226-9234. [PMID: 34165288 DOI: 10.1021/acs.analchem.1c01490] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Herein, a new strategy to increase the sensitivity of a lanthanide metal-organic framework (Ln-MOF) to UO22+ was proposed by using polymeric ligands. By utilizing [Tb(1,3,5-benzenetrisbenzoate)]n (Tb-TBT) MOF as the host, preloaded 2-vinyl terephthalic acid (VTP) was polymerized in situ, which produced a novel fluorescent composite denoted as PVTP⊂Tb-TBT. Benefiting from the coordination of PVTP to the Tb nodes, the polymeric chains performed both as molecular scaffolds that improved the water stability of the framework and as additional antennae that sensitized the photoluminescence of the Tb nodes. More importantly, the detection sensitivity and selectivity of PVTP⊂Tb-TBT to UO22+ were much improved compared to those of Tb-TBT. Detailed characterizations indicated that the incorporation of PVTP efficiently enriched UO22+ in the probe, which promoted the energy dissipation to UO22+. Besides, UO22+ was also supposed to release PVTP from PVTP⊂Tb-TBT and, thus, exposed the open metal sites to water molecules, which interrupted the sensitization effect of PVTP and induced a nonradiative energy dissipation. A limit of detection (LOD) as low as 0.75 nm was recorded by suspending the PVTP⊂Tb-TBT probe in a water sample, far below the limit in drinking water set by the United States Environmental Protection Agency (130 nm). Furthermore, a remotely controlled sampling and an on-site analysis of real water samples were realized by facilely loading PVTP⊂Tb-TBT on thin films (TFs). The LOD for UO22+ was 2.5 nm by using the TFs. This study reports a new strategy for boosting the sensitivity and selectivity of Ln-MOF to monitor UO22+ and expands the application of the strategy to an on-site analysis.
Collapse
Affiliation(s)
- Yuan-Jun Tong
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Lu-Dan Yu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Yanjun Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Qi Fu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Nan Li
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Sheng Peng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Sai Ouyang
- College of Chemistry and Chemical Engineering, Hunan Institute of Science and Technology, Yueyang 414006, Hunan, China
| | - Yu-Xin Ye
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L3G1, Ontario, Canada
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China.,Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou University, Kexue Avenue 100, Zhengzhou 450001, China.,Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangdong Academy of Sciences, 100 Xianlie Middle Road, Guangzhou 510070, China
| |
Collapse
|
49
|
Looby N, Roszkowska A, Reyes-Garcés N, Yu M, Bączek T, Kulasingam V, Pawliszyn J, Chandran V. Serum metabolic fingerprinting of psoriasis and psoriatic arthritis patients using solid-phase microextraction-liquid chromatography-high-resolution mass spectrometry. Metabolomics 2021; 17:59. [PMID: 34137950 PMCID: PMC8211611 DOI: 10.1007/s11306-021-01805-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 05/29/2021] [Indexed: 11/23/2022]
Abstract
INTRODUCTION Psoriatic arthritis (PsA), an inflammatory arthritis that develops in individuals with psoriasis, is associated with reduced quality of life. Identifying biomarkers associated with development of PsA as well as with PsA disease activity may help management of psoriatic disease. OBJECTIVES To use metabolomic fingerprinting to determine potential candidate markers of disease conversion (psoriasis to PsA) and/or PsA activity. METHODS A novel sample preparation protocol based on solid-phase microextraction (SPME) was used to prepare serum samples obtained from: (1) individuals with psoriasis, some of whom develop psoriatic arthritis (n = 20); (2) individuals with varying PsA activity (mild, moderate, severe; n = 10 each) and (3) healthy controls (n = 10). Metabolomic fingerprinting of the obtained extracts was performed using reversed-phase liquid chromatography coupled to high resolution mass spectrometry. RESULTS Psoriasis patients who developed PsA had similar metabolomic profiles to patients with mild PsA and were also indistinguishable from patients with psoriasis who did not develop PsA. Elevated levels of selected long-chain fatty acids (e.g., 3-hydroxytetradecanedioic acid) that are associated with dysregulation of fatty acid metabolism, were observed in patients with severe PsA. In addition, 1,11-undecanedicarboxylic acid-an unusual fatty acid associated with peroxisomal disorders-was also identified as a classifier in PsA patients vs. healthy individuals. Furthermore, a number of different eicosanoids with either pro- or anti-inflammatory properties were detected solely in serum samples of patients with moderate and severe PsA. CONCLUSION A global metabolomics approach was employed to analyze the serum metabolome of patients with psoriasis, PsA, and healthy controls in order to examine potential differences in the biochemical profiles at a metabolite level. A closer examination of circulating metabolites may potentially provide markers of PsA activity.
Collapse
Affiliation(s)
- Nikita Looby
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, ON, N2L 3G1, Canada
| | - Anna Roszkowska
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, ON, N2L 3G1, Canada
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Nathaly Reyes-Garcés
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, ON, N2L 3G1, Canada
| | - Miao Yu
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, ON, N2L 3G1, Canada
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland
| | - Vathany Kulasingam
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada.
- Division of Clinical Biochemistry, University Health Network, Toronto, Canada.
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue, Waterloo, ON, N2L 3G1, Canada.
| | - Vinod Chandran
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada.
- Department of Medicine, Division of Rheumatology, University of Toronto, Toronto, Canada.
- Institute of Medical Science, University of Toronto, Toronto, Canada.
- Schroeder Arthritis Institute, Krembil Research Institute, University Healthy Network, Toronto, ON, MT5 2S8, Canada.
| |
Collapse
|
50
|
Bojko B, Vasiljevic T, Boyaci E, Roszkowska A, Kraeva N, Ibarra Moreno CA, Koivu A, Wąsowicz M, Hanna A, Hamilton S, Riazi S, Pawliszyn J. Untargeted metabolomics profiling of skeletal muscle samples from malignant hyperthermia susceptible patients. Can J Anaesth 2021; 68:761-772. [PMID: 33403543 PMCID: PMC8185566 DOI: 10.1007/s12630-020-01895-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 07/29/2020] [Accepted: 07/29/2020] [Indexed: 01/09/2023] Open
Abstract
PURPOSE Malignant hyperthermia (MH) is a potentially fatal hypermetabolic condition triggered by certain anesthetics and caused by defective calcium homeostasis in skeletal muscle cells. Recent evidence has revealed impairment of various biochemical pathways in MH-susceptible patients in the absence of anesthetics. We hypothesized that clinical differences between MH-susceptible and control individuals are reflected in measurable differences in myoplasmic metabolites. METHODS We performed metabolomic profiling of skeletal muscle samples from MH-negative (control) individuals and MH-susceptible patients undergoing muscle biopsy for diagnosis of MH susceptibility. Cellular metabolites were extracted from 33 fresh and 87 frozen human muscle samples using solid phase microextraction and Metabolon® untargeted biochemical profiling platforms, respectively. Ultra-performance liquid chromatography-high resolution mass spectrometry was used for metabolite identification and validation, followed by analysis of differences in metabolites between the MH-susceptible and MH-negative groups. RESULTS Significant fold-change differences between the MH-susceptible and control groups in metabolites from various pathways were found (P value range: 0.009 to < 0.001). These included accumulation of long chain acylcarnitines, diacylglycerols, phosphoenolpyruvate, histidine pathway metabolites, lysophosphatidylcholine, oxidative stress markers, and phosphoinositols, as well as decreased levels of monoacylglycerols. The results from both analytical platforms were in agreement. CONCLUSION This metabolomics study indicates a shift from utilization of carbohydrates towards lipids for energy production in MH-susceptible individuals. This shift may result in inefficiency of beta-oxidation, and increased muscle protein turnover, oxidative stress, and/or lysophosphatidylcholine levels.
Collapse
Affiliation(s)
- Barbara Bojko
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, Bydgoszcz, Poland
| | - Tijana Vasiljevic
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| | - Ezel Boyaci
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- Department of Chemistry, Middle East Technical University, Ankara, Turkey
| | - Anna Roszkowska
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
- Department of Pharmaceutical Chemistry, Medical University of Gdansk, Gdansk, Poland
| | - Natalia Kraeva
- Malignant Hyperthermia Investigation Unit, Department of Anesthesia, University Health Network, University of Toronto, 323-200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada
| | - Carlos A Ibarra Moreno
- Malignant Hyperthermia Investigation Unit, Department of Anesthesia, University Health Network, University of Toronto, 323-200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada
| | - Annabel Koivu
- Malignant Hyperthermia Investigation Unit, Department of Anesthesia, University Health Network, University of Toronto, 323-200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada
| | - Marcin Wąsowicz
- Malignant Hyperthermia Investigation Unit, Department of Anesthesia, University Health Network, University of Toronto, 323-200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada
| | - Amy Hanna
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, USA
| | - Susan Hamilton
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, USA
| | - Sheila Riazi
- Malignant Hyperthermia Investigation Unit, Department of Anesthesia, University Health Network, University of Toronto, 323-200 Elizabeth Street, Toronto, ON, M5G 2C4, Canada.
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|