1
|
van Outersterp RE, Martens J, Peremans A, Lamard L, Cuyckens F, Oomens J, Berden G. Evaluation of table-top lasers for routine infrared ion spectroscopy in the analytical laboratory. Analyst 2021; 146:7218-7229. [PMID: 34724520 PMCID: PMC8607882 DOI: 10.1039/d1an01406d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 10/20/2021] [Indexed: 01/12/2023]
Abstract
Infrared ion spectroscopy is increasingly recognized as a method to identify mass spectrometry-detected analytes in many (bio)chemical areas and its integration in analytical laboratories is now on the horizon. Commercially available quadrupole ion trap mass spectrometers are attractive ion spectroscopy platforms but operate at relatively high pressures. This promotes collisional deactivation which directly interferes with the multiple-photon excitation process required for ion spectroscopy. To overcome this, infrared lasers having a high instantaneous power are required and therefore a majority of analytical studies have been performed at infrared free electron laser facilities. Proliferation of the technique to routine use in analytical laboratories requires table-top infrared lasers and optical parametric oscillators (OPOs) are the most suitable candidates, offering both relatively high intensities and reasonable spectral tuning ranges. Here, we explore the potential of a range of commercially available high-power OPOs for ion spectroscopy, comparing systems with repetition rates of 10 Hz, 20 kHz, 80 MHz and a continuous-wave (cw) system. We compare the performance for various molecular ions and show that the kHz and MHz repetition-rate systems outperform cw and 10 Hz systems in photodissociation efficiency and offer several advantages in terms of cost-effectiveness and practical implementation in an analytical laboratory not specialized in laser spectroscopy.
Collapse
Affiliation(s)
- Rianne E van Outersterp
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands.
| | - Jonathan Martens
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands.
| | - André Peremans
- Laboratoire Physique de la Matière et du Rayonnement (P.M.R), Université de Namur, 5000 Namur, Belgium
| | | | - Filip Cuyckens
- Drug Metabolism & Pharmacokinetics, Janssen R&D, Beerse, Belgium
| | - Jos Oomens
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands.
- Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, P.O. Box 94157, 1090 GD Amsterdam, The Netherlands
| | - Giel Berden
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands.
| |
Collapse
|
2
|
Namour M, El Mobadder M, Magnin D, Peremans A, Verspecht T, Teughels W, Lamard L, Nammour S, Rompen E. Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface. Dent J (Basel) 2019; 7:dj7040099. [PMID: 31581536 PMCID: PMC6960958 DOI: 10.3390/dj7040099] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 09/19/2019] [Accepted: 09/24/2019] [Indexed: 01/04/2023] Open
Abstract
Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.
Collapse
Affiliation(s)
- Melanie Namour
- Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium.
| | - Marwan El Mobadder
- Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium.
| | - Delphine Magnin
- Bio- and Soft Matter Division, Institute of Condensed and Nanosciences, Université Catholique de Louvain (UCL), 1348-Louvain-la-Neuve, Belgium.
| | - André Peremans
- Laboratoire Physique de la Matière et du Rayonnement (P.M.R.), Université de Namur, 5000 Namur, Belgium.
| | - Tim Verspecht
- Department of Oral Health Sciences, University of Leuven (K.U. Leuven), 3000 Leuven, Belgium.
| | - Wim Teughels
- Department of Oral Health Sciences, University of Leuven (K.U. Leuven) and Dentistry, University Hospitals Leuven, 3000 Leuven, Belgium.
| | | | - Samir Nammour
- Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium.
| | - Eric Rompen
- Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium.
| |
Collapse
|
3
|
Lamard L, Balslev-Harder D, Peremans A, Petersen JC, Lassen M. Versatile photoacoustic spectrometer based on a mid-infrared pulsed optical parametric oscillator. Appl Opt 2019; 58:250-256. [PMID: 30645301 DOI: 10.1364/ao.58.000250] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 12/02/2018] [Indexed: 06/09/2023]
Abstract
We demonstrate the usefulness of a nanosecond-pulsed single-mode mid-infrared (MIR) optical parametric oscillator (OPO) for photoacoustic (PA) spectroscopic measurements. The maximum wavelength ranges for the signal and idler are 1.4 μm to 1.7 μm and 2.8 μm to 4.6 μm, respectively, with a MIR output power of up to 500 mW, making the OPO useful for different spectroscopic PA trace-gas measurements targeting the major market opportunity of environmental monitoring and breath gas analysis. We perform spectroscopic measurements of methane (CH4), nitrogen dioxide (NO2), and ammonia (NH3) in the 2.8 μm to 3.7 μm wavelength region. The measurements were conducted with a constant flow rate of 300 mL/min, thus demonstrating the suitability of the gas sensor for real-time trace-gas measurements. The acquired spectra are compared with data from the HITRAN database, and good agreement is found, demonstrating a resolution bandwidth of 1.5 cm1. An Allan deviation analysis shows that the detection limit for methane at optimum integration time for the PA sensor is 8 ppbV (nmol/mol) at 105 s of integration time, corresponding to a normalized noise equivalent absorption coefficient of 2.9×10-7 W cm-1 Hz-1/2.
Collapse
|
4
|
Lassen M, Lamard L, Feng Y, Peremans A, Petersen JC. Off-axis quartz-enhanced photoacoustic spectroscopy using a pulsed nanosecond mid-infrared optical parametric oscillator: publisher's note. Opt Lett 2018; 43:5667. [PMID: 30439922 DOI: 10.1364/ol.43.005667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Indexed: 06/09/2023]
Abstract
This publisher's note corrects an affiliation error in Opt. Lett.41, 4118 (2016)OPLEDP0146-959210.1364/OL.41.004118.
Collapse
|
5
|
Lassen M, Lamard L, Feng Y, Peremans A, Petersen JC. Off-axis quartz-enhanced photoacoustic spectroscopy using a pulsed nanosecond mid-infrared optical parametric oscillator. Opt Lett 2016; 41:4118-4121. [PMID: 27607987 DOI: 10.1364/ol.41.004118] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Accepted: 08/09/2016] [Indexed: 06/06/2023]
Abstract
A trace-gas sensor, based on quartz-enhanced photoacoustic spectroscopy (QEPAS), consisting of two acoustically coupled micro-resonators (mR) with an off-axis 20 kHz quartz tuning fork (QTF) is demonstrated. The complete acoustically coupled mR system is optimized based on finite-element simulations and is experimentally verified. The QEPAS sensor is pumped resonantly by a nanosecond pulsed single-mode mid-infrared optical parametric oscillator. The sensor is used for spectroscopic measurements on methane in the 3.1-3.5 μm wavelength region with a resolution bandwidth of 1 cm-1 and a detection limit of 0.8 ppm. An Allan deviation analysis shows that the detection limit at the optimum integration time for the QEPAS sensor is 32 ppbv at 190 s, and that the background noise is due solely to the thermal noise of the QTF.
Collapse
|
6
|
Bahrami B, Askari N, Tielemans M, Heysselaer D, Lamard L, Peremans A, Nyssen-Behets C, Nammour S. Effect of low fluency dentin conditioning on tensile bond strength of composite bonded to Er:YAG laser-prepared dentin: a preliminary study. Lasers Med Sci 2010; 26:187-91. [PMID: 20309596 DOI: 10.1007/s10103-010-0767-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2009] [Accepted: 02/08/2010] [Indexed: 11/25/2022]
Abstract
Several studies in the literature have previously shown that the bond strength of a composite bonded to dentin is almost equivalent as when dentin is prepared by either bur or Er:YAG laser. The aim of this preliminary study is to assess the hypothesis that dentin conditioning at low fluency by means of Er:YAG laser can improve the value of adhesion of composites resin to dentin. Sixty surfaces of caries-free human third molars extracted for orthodontic purposes were randomly divided into five groups of 12 teeth. The bur group was the control, prepared using bur, group L was prepared using Er:YAG 200 mJ, SSP (50 µs), 20 Hz, 15 seconds of sweeping, for groups L80, L100, L120, they were prepared first, with the same parameters of the group L 200, and then they received a conditioning, which is, respectively, 15 s of irradiations at: 80 mJ (SSP, 10 Hz), 100 mJ (SSP, 10 Hz), and 120 mJ (SSP, 10 Hz). All samples were restored in a single-component adhesive system: Xenon (DENTSPLY), and ceramX (DENTSPLY) as the resin composite. The specimens were submitted to tensile bond strength test using a universal testing machine. Data were submitted to statistical analysis using ANOVA coupled to a Tukey-Kramer test at the 95% level. The mean values in MPa were 33.3 for group B, 36.73 for group L 200, 41.7 for group L80, 37.9 for group L100, and 39.1 for group L120. Our results showed that dentin conditioning at a low fluency of 12.58 J/cm(2) per pulse, with 80 mJ output energy and 50-µs pulse duration can significantly improve tensile bond strength of a composite bonded to Er:YAG laser-prepared dentine.
Collapse
Affiliation(s)
- B Bahrami
- Department of Dental Sciences, Faculty of Medicine, University of Liege, Liege, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Chousterman M, Heysselaer D, Dridi SM, Bayet F, Misset B, Lamard L, Peremans A, Nyssen-Behets C, Nammour S. Effect of acid etching duration on tensile bond strength of composite resin bonded to erbium:yttrium-aluminium-garnet laser-prepared dentine. Preliminary study. Lasers Med Sci 2009; 25:855-9. [PMID: 19685196 DOI: 10.1007/s10103-009-0719-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2009] [Accepted: 07/15/2009] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to compare the tensile bond strength of composite resin bonded to erbium:yttrium-aluminium-garnet (Er:YAG) laser-prepared dentine after different durations of acid etching. The occlusal third of 68 human third molars was removed in order to expose the dentine surface. The teeth were randomly divided into five groups: group B (control group), prepared with bur and total etch system with 15 s acid etching [37% orthophosphoric acid (H(3)PO(4))]; group L15, laser photo-ablated dentine (200 mJ) (laser irradiation conditions: pulse duration 100 micros, air-water spray, fluence 31.45 J/ cm(2), 10 Hz, non-contact hand pieces, beam spot size 0.9 mm, irradiation speed 3 mm/s, and total irradiation time 2 x 40 s); group L30, laser prepared, laser conditioned and 30 s acid etching; group L60, laser prepared, laser conditioned and 60 s acid etching; group L90, laser prepared, laser conditioned and 90 s acid etching. A plot of composite resin was bonded onto each exposed dentine and then tested for tensile bond strength. The values obtained were statistically analysed by analysis of variance (ANOVA) coupled with the Tukey-Kramer test at the 95% level. A 90 s acid etching before bonding showed the best bonding value (P < 0.05) when compared with all the other groups including the control group. There is no significance difference between other groups, nor within each group and the control group. There was a significant increase in tensile bond strength of the samples acid etched for 90 s.
Collapse
Affiliation(s)
- M Chousterman
- Department of Dental Sciences, Faculty of Medicine, University of Liege, Quai Godfroid Kurth, 45, 4000, Liege, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
El Yazami H, Zeinoun T, Bou Saba S, Lamard L, Peremans A, Limme M, Geerts S, Lamy M, Nammour S. Pulp temperature increase during photo-activated disinfection (PAD) of periodontal pockets: an in vitro study. Lasers Med Sci 2009; 25:655-9. [PMID: 19529881 DOI: 10.1007/s10103-009-0686-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2008] [Accepted: 05/12/2009] [Indexed: 11/29/2022]
Abstract
The capacity of photo-sensitizers, used in combination with laser light to kill micro-organisms has been demonstrated in different studies. Photo-activated disinfection (PAD) has been introduced in periodontology as an aid for disinfection of periodontal pockets. The aim of this study is to verify the harm for dental vitality of the use of PAD in periodontal pockets. Root canals of 24 freshly extracted human teeth where prepared using profiles up to a size of ISO #50 and filled with thermo-conductor paste. A silicon-based false gum was made in which a periodontal pocket was created and filled with photo-sensitizer phenothiazine chloride (phenothiazine-5-ium, 3.7-bis (dimethylamino)-, chloride). The external root surface was irradiated during 60 s with a 660-nm diode laser (output power: 20 mW; power density: 0.090 W/cm(2); Energy density: 5.46 J/cm(2)) using a periodontal tip with a diameter of 1 mm and a length of 7 mm. Temperatures were recorded inside the root canal using a thermocouple. Measurements were recorded every second, starting at 10 s before lasering, during the irradiation and were continued for 150 s after the end of irradiation, and six measurements were done per tooth. An average temperature increase of 0.48 +/- 0.11 degrees C was recorded. Our results demonstrated that pulp temperature increase was lower than 3 degrees C, which is considered to be harmless for pulp injury. Regarding pulp temperature increase, the use of PAD for disinfection of periodontal pockets can be considered as a safe procedure for dental vitality.
Collapse
Affiliation(s)
- H El Yazami
- Department of Dental Sciences, Faculty of Medicine, University of Liege, Liege, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Lamard L, Pérault MC, Bouquet S, Guibert S. [Cytochrome p450 IID6, its role in psychopharmacology]. Ann Med Psychol (Paris) 1995; 153:140-3. [PMID: 7741408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Cytochrome P450 IID6 has got typical features (genetical polymorphism, competitive inhibition, saturability) which can be at the origin of pharmacokinetic modifications of molecules using it for their metabolism. In the field of pharmacology, many molecules are substrates or inhibitors of this cytochrome. They are presented. The results of a study of the dextromethorphan variation test performed before and after 28 days of clomipramine therapy with depressed patients are explained. They show a significant decreasing of the cytochrome P450 IID6 oxidation capacities between both of these times. A patient has passed from the phenotype "effective metabolizer" to the one of "poor metabolizer" with clomipramine.
Collapse
|