Gómez Medina AM, Parra Prieto DA, Henao Carrillo DC, Gómez CM, Muñoz Velandia OM, Caicedo S, Kerguelen Villadiego AL, Rodríguez Hortúa LM, Lucero Pantoja OD, Uribe Valencia M, García Guete MM, Robledo Gómez S, Rondón Sepúlveda M. Characteristics Associated With Elevated Time Below Range in Elderly Patients With Type 1 Diabetes Using an Automated Insulin Delivery System.
J Diabetes Sci Technol 2024:19322968241232659. [PMID:
38506435 DOI:
10.1177/19322968241232659]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
BACKGROUND
This study investigated the characteristics associated with an increased risk of hypoglycemia, in elderly patients with type 1 diabetes mellitus (T1D) using automated insulin delivery (AID) systems.
METHODS
Cross-sectional observational study including patients >60 years, using sensor-augmented insulin pump therapy with predictive low-glucose management (SAPT-PLGM), hybrid closed-loop (HCL), and advanced hybrid closed-loop (AHCL), for more than three months. A geriatric assessment was performed, and body composition was determined to investigate its association with achieving time below range (TBR) <70 mg/dL goals.
RESULTS
The study included 59 patients (47.5% of men, mean age of 67.6 years, glycated hemoglobin [HbA1c] of 7.5 ± 0.6%, time in range (TIR) 77.8 ± 9.9%). Time below range <70 and <54 mg/dL were 2.2 ± 2.3% and 0.4 ± 0.81%, respectively. Patients with elevated TBR <70 mg/dL (>1%) had higher HbA1c levels, lower TIR, elevated time above range (TAR), and high glycemic variability. Regarding body composition, greater muscle mass, grip strength, and visceral fat were associated with a lower TBR <70 mg/dL. These factors were independent of the type of technology used, but TIR was higher when using AHCL systems compared with SAPT-PLGM and HCL systems.
CONCLUSIONS
In elderly patients treated with AID systems with good functional status, lower lean mass, lower grip strength, and lower visceral fat percentage were associated with TBR greater than 1%, regardless of the device used. A similar finding along was found with CGM indicators such as higher HbA1c levels, lower TIR, higher TAR, and higher CV. Geriatric assessment is crucial for personalizing patient management.