1
|
Darban Hosseini S, Kachoei M, Faramarzi M, Esmaeilzadeh M. Comparison of radiographic changes in the alveolar crest after extraction of fully and partially erupted premolars during orthodontic treatment: A retrospective analytical study. J Dent Res Dent Clin Dent Prospects 2021; 15:279-284. [PMID: 35070183 PMCID: PMC8760372 DOI: 10.34172/joddd.2021.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Accepted: 08/11/2020] [Indexed: 11/09/2022] Open
Abstract
Background. The alveolar process plays an essential role in providing dental support and gradually disappears with tooth loss. Space deficiency can cause one premolar to remain semi-erupted adjacent to a fully-erupted premolar. During orthodontic treatment, each of these premolars can be extracted. This retrospective study aimed to compare radiographic changes of the alveolar crest due to orthodontic movements of fully-erupted and semi-erupted premolars into the extraction sites before and after treatment.
Methods. The patients were divided into the fully-erupted premolar extraction (first) group and the semi-erupted premolar extraction (second) group. The distance between the cementoenamel junction (CEJ) and the alveolar crest, from the distal aspect of the canine to the mesial aspect of the first molar, was measured on panoramic radiographs of 78 patients (39 from each group) before and after treatment with a digital caliper. Changes in the alveolar crest were compared between the two groups. Finally, the height differences of the alveolar crest in mesial and distal aspects of the remaining premolars in both groups were calculated at the end of treatment. Descriptive statistical analyses and paired and independent t tests were used in the study.
Results. The distance from the CEJ to the alveolar crest at mesial and distal aspects in the first group and the distal aspect of the extraction site in the second group increased significantly. However, changes at the mesial aspect were not significant in the second group. Comparing the alveolar crest height between the two groups and between the mesial and distal aspects of the remaining premolar tooth indicated no significant differences.
Conclusion. No significant difference was observed between the extraction of a fully-erupted or semi-erupted premolar to obtain greater alveolar height.
Collapse
Affiliation(s)
| | - Mojgan Kachoei
- Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Masoumeh Faramarzi
- Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahdiyeh Esmaeilzadeh
- Dental Student, Student Research Committee, Tabriz University of Medical Science, Tabriz, Iran
| |
Collapse
|
2
|
Shirazi S, Kachoei M, Shahvaghar-Asl N, Shirazi S, Sharghi R. Arch width changes in patients with Class II division 1 malocclusion treated with maxillary first premolar extraction and non-extraction method. J Clin Exp Dent 2016; 8:e403-e408. [PMID: 27703608 PMCID: PMC5045687 DOI: 10.4317/jced.52840] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 01/27/2016] [Indexed: 11/10/2022] Open
Abstract
Background The aim of this study was to determine arch width changes during maxillary first premolars extraction and non-extraction treatment in patients with Class II division 1 malocclusion. Material and Methods Dental casts of 91 Class II division 1 patients (36 males and 55 females) were evaluated. The minimum age of the subjects at the beginning of treatment was above 16 years. 48 patients were treated with extraction of the maxillary first premolars and 43 patients were treated without extraction. Pre- and post-treatment maxillary and mandibular inter-canine and inter-molar arch widths were measured. Results At the end of treatment, maxillary and mandibular inter-canine widths of both groups increased significantly. The maxillary inter-molar width decreased in the extraction group and increased in the non-extraction group. The mandibular inter-molar width increased significantly in both groups. No significant differences were observed between males and females. Conclusions The results of this study indicated that there was a tendency for an increase in arch width during both the extraction and non-extraction treatment except maxillary inter-molar width in the extraction cases. Key words:Dental arch, malocclusion, angle Class II, tooth movement, extraction.
Collapse
Affiliation(s)
- Sajjad Shirazi
- Lecturer and Faculty Member, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran; Research Fellow, Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mojgan Kachoei
- Associate Professor, Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Naiemeh Shahvaghar-Asl
- Post Graduate Student, Department of Pediatric Dentistry, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran
| | - Samaneh Shirazi
- Under Graduate Student, Student Research Committee, Faculty of Paramedicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Reza Sharghi
- Assistant Professor of Orthodontics, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran
| |
Collapse
|
3
|
Kachoei M, Nourian A, Divband B, Kachoei Z, Shirazi S. Zinc-oxide nanocoating for improvement of the antibacterial and frictional behavior of nickel-titanium alloy. Nanomedicine (Lond) 2016; 11:2511-27. [PMID: 27623286 DOI: 10.2217/nnm-2016-0171] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
AIM To fabricate a friction-reducing and antibacterial coating with zinc oxide (ZnO) nanoparticles on nickel-titanium (NiTi) wire. MATERIALS & METHODS NiTi orthodontic wires were coated with ZnO nanoparticles using the chemical deposition method. Characteristics of the coating as well as the physical, mechanical and antibacterial properties of the wires were investigated. RESULTS A stable and well-adhered ZnO coating on the NiTi wires was obtained. The hardness and elastic modulus of the ZnO nanocoating were 2.3 ± 0.2 and 61.0 ± 3.6 GPa, respectively. The coated wires presented up to 21% reduction in the frictional forces and antibacterial activity against Streptococcus mutans. ZnO nanocoating significantly improved the surface quality of NiTi wires. The modulus of elasticity, unloading forces and austenite finish temperature were not significantly different after coating. CONCLUSION This unique coating could be implemented into practice for safer and faster treatment to the benefit of both patient and clinician.
Collapse
Affiliation(s)
- Mojgan Kachoei
- Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Azin Nourian
- Department of Orthodontics, Faculty of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Baharak Divband
- Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Zahra Kachoei
- Polymer Division, Chemistry Department, School of Science, University of Tehran, Tehran, Iran
| | - Sajjad Shirazi
- Dental and Periodontal Research Center, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran.,Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
4
|
Kachoei M, Mohammadi A, Esmaili Moghaddam M, Rikhtegaran S, Pourghaznein M, Shirazi S. Comparison of multiple rebond shear strengths of debonded brackets after preparation with sandblasting and CO2 laser. J Dent Res Dent Clin Dent Prospects 2016; 10:148-54. [PMID: 27651880 PMCID: PMC5025215 DOI: 10.15171/joddd.2016.024] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 06/28/2016] [Indexed: 11/16/2022] Open
Abstract
Background. Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. Different techniques have been suggested in the literature to remove resin residues from the bracket bases and enamel surfaces to prepare the surfaces again after debonding. This study attempted to compare multiple rebond shear strengths (SBS) of debonded brackets following preparation with sandblasting and CO2 laser. Methods. The brackets were bonded on 30 human and bovine maxillary central incisors using self-curing composite resin. SBS was measured using Hounsfield testing machine. The brackets were rebonded for two other times after composite resin residues on their surfaces were removed, either with air abrasion or CO2 laser. The debonded brackets and enamel surfaces were also evaluated after each debonding procedure under a stereomicroscope in order to determine adhesive remnant index (ARI). SBS of debonded brackets after each step were compared between sandblast and CO2 laser groups. Results. We observed significant differences in SBS values between pre-recycling and first (P = 0.04), second (P = 0.007) and third recycling (P = 0.007) with laser. Recycling with sandblasting resulted in a decrease in SBS after the first and second recycling procedure; however, the SBS increased after the third recycling procedure, with no significant differences. Conclusion. SBS of brackets after recycling with sandblasting and laser beams was not significantly different, and both were at a favorable level. However, repeating the recycling procedure with sandblasting resulted in more favorable SBS compared to laser.
Collapse
Affiliation(s)
- Mojgan Kachoei
- Associate Professor, Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir Mohammadi
- Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Maziar Esmaili Moghaddam
- Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Urmia University of Medical Sciences, Urmia, Iran
| | - Sahand Rikhtegaran
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Pourghaznein
- Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Qom University of Medical Sciences, Qom, Iran
| | - Sajjad Shirazi
- Research Fellow and Lecturer, Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
5
|
Behroozian A, Kachoei M, Khatamian M, Divband B. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets. J Dent Res Dent Clin Dent Prospects 2016; 10:106-11. [PMID: 27429727 PMCID: PMC4945159 DOI: 10.15171/joddd.2016.017] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Accepted: 05/03/2016] [Indexed: 11/21/2022] Open
Abstract
Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction.
Collapse
Affiliation(s)
- Ahmad Behroozian
- Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mojgan Kachoei
- Associate Professor, Department Of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Masumeh Khatamian
- Professor, Inorganic Chemistry Department, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Baharak Divband
- Researcher, Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
6
|
Oskoee PA, Kachoei M, Rikhtegaran S, Fathalizadeh F, Navimipour EJ. Effect of surface treatment with sandblasting and Er,Cr:YSGG laser on bonding of stainless steel orthodontic brackets to silver amalgam. Med Oral Patol Oral Cir Bucal 2012; 17:e292-6. [PMID: 22143706 PMCID: PMC3448331 DOI: 10.4317/medoral.17473] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2011] [Accepted: 05/09/2011] [Indexed: 12/05/2022] Open
Abstract
Objectives: Satisfactory bonding of orthodontic attachments to amalgam is a challenge for orthodontists. The aim of this in vitro study was to compare the shear bond strength of stainless steel orthodontic brackets to silver amalgam treated with sandblasting and Er,Cr:YSGG laser.
Study Design: Fifty-four amalgam discs were prepared, polished and divided into three groups: In group 1 (the control group) the premolar brackets were bonded using Panavia F resin cement without any surface treatment; in groups 2 and 3, the specimens were subjected to sandblasting and Er,Cr:YSGG laser respectively, before bracket bonding.
After immersing in distilled water at 37°C for 24 hours, all the specimens were tested for shear bond strength. Bond failure sites were evaluated under a stereomicroscope. Data was analyzed using one-way ANOVA and a post hoc Tukey test.
Results: The highest and lowest shear bond strength values were recorded in the laser and control groups, respectively. There were significant differences in mean shear bond strength values between the laser and the other two groups (p<0.05). However, there were no significant differences between the sandblast and control groups (p=0.5).
Conclusions: Amalgam surface treatment with Er,Cr:YSGG laser increased shear bond strength of stainless steel orthodontic brackets.
Key words: Amalgam, surface treatment, shear bond strength, sandblasting, Er,Cr:YSGG laser.
Collapse
Affiliation(s)
- P-A Oskoee
- Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Daneshgah St., Azadi St., Tabriz, Iran.
| | | | | | | | | |
Collapse
|
7
|
|
8
|
Kachoei M, Behroozian A. "3D bite": A new appliance device for registration of construction bite. Dent Res J (Isfahan) 2012; 9:826-7. [PMID: 23559967 PMCID: PMC3612239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Affiliation(s)
- Mojgan Kachoei
- Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran,Address for correspondence: Prof. Mojgan Kachoei, Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Daneshgah St., Azadi St., Tabriz, Iran. E-mail:
| | - Ahmad Behroozian
- Department of Orthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
9
|
Kachoei M, Ahangar-Atashi MH, Pourkhamneh S. Bolton s intermaxillary tooth size ratios among Iranian schoolchildren. Med Oral Patol Oral Cir Bucal 2011; 16:e568-72. [PMID: 21196874 DOI: 10.4317/medoral.16.e568] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2010] [Accepted: 08/18/2010] [Indexed: 11/05/2022] Open
|
10
|
Ahangar-Atashi MH, Kachoei M. Effect of chin position on natural head orientation reproducibility. Med Oral Patol Oral Cir Bucal 2011; 16:e317-22. [DOI: 10.4317/medoral.16.e317] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2010] [Accepted: 08/06/2010] [Indexed: 11/05/2022] Open
|