1
|
Functionalizing Carbon Substrates with a Covalently Attached Cobalt Redox Buffer for Calibration-Free Solid-Contact Ion-Selective Electrodes. Anal Chem 2024; 96:7558-7565. [PMID: 38696396 DOI: 10.1021/acs.analchem.4c00373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2024]
Abstract
With a view to potentiometric sensing with minimal calibration requirements and high long-term stability, colloid-imprinted mesoporous (CIM) carbon was functionalized by the covalent attachment of a cobalt redox buffer and used as a new solid contact for ion-selective electrodes (ISEs). The CIM carbon surface was first modified by electroless grafting of a terpyridine ligand (Tpy-ph) using diazonium chemistry, followed by stepwise binding of Co(II) and an additional Tpy ligand to the grafted ligand, forming a bis(terpyridine) Co(II) complex, CIM-ph-Tpy-Co(II)-Tpy. Half a molar equivalent of ferrocenium tetrakis(3-chlorophenyl)borate was then used to partially oxidize the Co(II) complex. Electrodes prepared with this surface-attached CIM-ph-Tpy-Co(III/II)-Tpy redox buffer as a solid contact were tested as K+ sensors in combination with valinomycin as the ionophore and Dow 3140 silicone or plasticized poly(vinyl chloride) (PVC) as the matrixes for the ion-selective membrane (ISM). This solid contact is characterized by a redox capacitance of 3.26 F/g, ensuring a well-defined interfacial potential that underpins the transduction mechanism. By use of a redox couple as an internal reference element to control the phase boundary potential at the interface of the ISM and the CIM carbon solid contact, solid-contact ion-selective electrodes (SC-ISEs) with a standard deviation of E° as low as 0.3 mV for plasticized PVC ISMs and 3.5 mV for Dow 3140 silicone ISMs were obtained. Over 100 h, these SC-ISEs exhibit an emf drift of 20 μV/h for plasticized PVC ISMs and 62 μV/h for silicone ISMs. The differences in long-term stability and reproducibility between electrodes with ISMs comprising either a plasticized PVC or silicone matrix offer valuable insights into the effect of the polymeric matrix on sensor performance.
Collapse
|
2
|
Ion-Selective Potentiometry with Plasma-Initiated Covalent Attachment of Sensing Membranes onto Inert Polymeric Substrates and Carbon Solid Contacts. Anal Chem 2024; 96:4702-4708. [PMID: 38451778 DOI: 10.1021/acs.analchem.4c00204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
The physical delamination of the sensing membrane from underlying electrode bodies and electron conductors limits sensor lifetimes and long-term monitoring with ion-selective electrodes (ISEs). To address this problem, we developed two plasma-initiated graft polymerization methods that attach ionophore-doped polymethacrylate sensing membranes covalently to high-surface-area carbons that serve as the conducting solid contact as well as to polypropylene, poly(ethylene-co-tetrafluoroethylene), and polyurethane as the inert polymeric electrode body materials. The first strategy consists of depositing the precursor solution for the preparation of the sensing membranes onto the platform substrates with the solid contact carbon, followed by exposure to an argon plasma, which results in surface-grafting of the in situ polymerized sensing membrane. Using the second strategy, the polymeric platform substrate is pretreated with argon plasma and subsequently exposed to ambient oxygen, forming hydroperoxide groups on the surface. Those functionalities are then used for the initiation of photoinitiated graft polymerization of the sensing membrane. Attenuated total reflection-Fourier transform infrared spectroscopy, water contact angle measurements, and delamination tests confirm the covalent attachment of the in situ polymerized sensing membranes onto the polymeric substrates. Using membrane precursor solutions comprising, in addition to decyl methacrylate and a cross-linker, also 2-(diisopropylamino)ethyl methacrylate as a covalently attachable H+ ionophore and tetrakis(pentafluorophenyl)borate as ionic sites, both plasma-based fabrication methods produced electrodes that responded to pH in a Nernstian fashion, with the high selectivity expected for ionophore-based ISEs.
Collapse
|
3
|
Covalently attached ionophores extend the working range of potentiometric pH sensors with poly(decyl methacrylate) sensing membranes. Analyst 2024; 149:1132-1140. [PMID: 38205703 DOI: 10.1039/d3an02047a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
The pH working range of solid-contact ion-selective electrodes (ISEs) with plasticizer-free poly(decyl methacrylate) sensing membranes is shown to be expanded by covalent attachment of H+ ionophores to the polymeric membrane matrix. In situ photopolymerization not only incorporates the ionophores into the polymer backbone, but at the same time also attaches the sensing membranes covalently to the underlying inert polymer and nanographite solid contact, minimizing sensor drift and preventing failure by membrane delamination. A new pyridine-based H+ ionophore, 3-(pyridine-3-yl)propyl methacrylate, has lower basicity than trialkylamine ionophores and expands the upper detection limit. This reduces in particular the interference from hydrogen phthalate, which is a common component of commercial pH buffers. Moreover, the lower detection limit is improved by replacing the CH2CH2 spacer of previously reported dialkylaminoethyl methacrylates with a (CH2)10 spacer, which increases its basicity. Notably, for the more basic and highly cation-selective ionophore 10-(diisopropylamino)decyl methacrylate, the extent of counterion interference from hydrogen phthalate shifted the upper detection limit to lower pH by nearly one pH unit when the crosslinker concentration was decreased.
Collapse
|
4
|
Microporous Ag/AgCl on a Titanium Scaffold for Use in Capillary Reference Electrodes. Anal Chem 2024; 96:2236-2243. [PMID: 38277487 DOI: 10.1021/acs.analchem.3c05382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2024]
Abstract
AgCl-coated silver fabricated with the thermal-electrolytic method can be used to prepare more reproducible reference electrodes than Ag/AgCl prepared with alternative methods such as electrolytic and chemical AgCl deposition or thermal fabrication. However, thermal-electrolytic fabrication requires a scaffold material upon which to build the layers upon. Platinum and rhodium have been used for this purpose as they are mechanically strong and chemically inert, but their cost is prohibitive for wider application. Herein, we report the stability of Ag/AgCl reference electrodes built atop a titanium scaffold using the thermal-electrolytic method and the use of these Ti/Ag/AgCl constructs in capillary-based reference electrodes. Electrochemical characterization shows that the probable presence of small amounts of oxygen at the Ti/Ag interface does not affect the reference electrode performance; in particular, over a wide pH range, the half-cell potential is pH independent. The electrical resistance of the Ti/Ag/AgCl/KCl system is dominated by the charge transfer resistance at the interface of the AgCl to KCl solution but is kept very small by the large AgCl surface area and a high solution concentration of chloride. The resulting high exchange current minimizes the effect of system impurities on the reference half-cell potential. Capillary-based reference electrodes comprising Ti/Ag/AgCl show exceptionally low potential drifts (as low as 0.03 ± 2.01 μV/h) and standard deviations of the potential at or below ±0.5 mV over a 60 h period. These capillary-based reference electrodes are suitable for very small sample volumes while still providing a free-flowing liquid junction that prevents reference electrode contamination.
Collapse
|
5
|
Design Criteria for Nanostructured Carbon Materials as Solid Contacts for Ion-Selective Sensors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2309778. [PMID: 38105339 DOI: 10.1002/adma.202309778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/05/2023] [Indexed: 12/19/2023]
Abstract
The ability to miniaturize ion-selective sensors that enable microsensor arrays and wearable sensor patches for ion detection in environmental or biological samples requires all-solid-state sensors with solid contacts for transduction of an ion activity into an electrical signal. Nanostructured carbon materials function as effective solid contacts for this purpose. They can also contribute to improved potential signal stability, reducing the need for frequent sensor calibration. In this Perspective, the structural features of various carbon-based solid contacts described in the literature and their respective abilities to reduce potential drift during long-term, continuous measurements are compared. These carbon materials include nanoporous carbons with various architectures, carbon nanotubes, carbon black, graphene, and graphite-based solid contacts. The effects of accessibility of ionophores, ionic sites, and other components of an ion-selective membrane to the internal or external carbon surfaces are discussed, because this impacts double-layer capacitance and potential drift. The effects of carbon composition on water-layer formation are also considered, which is another contributor to potential drift during long-term measurements. Recommendations regarding the selection of solid contacts and considerations for their characterization and testing in solid-contact ion-selective electrodes are provided.
Collapse
|
6
|
Effect of Ion Identity on Capacitance and Ion-to-Electron Transduction in Ion-Selective Electrodes with Nanographite and Carbon Nanotube Solid Contacts. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:1785-1792. [PMID: 38198594 DOI: 10.1021/acs.langmuir.3c03027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
The use of large surface area carbon materials as transducers in solid-contact ion-selective electrodes (ISEs) has become widespread. Desirable qualities of ISEs, such as a small long-term drift, have been associated with a high capacitance that arises from the formation of an electrical double layer at the interface of the large surface area carbon material and the ion-selective membrane. The capacitive properties of these ISEs have been observed using a variety of techniques, but the effects of the ions present in the ion-selective membrane on the measured value of the capacitance have not been studied in detail. Here, it is shown that changes in the size and concentration of the ions in the ion-selective membrane as well as the polarity of the polymeric matrix result in capacitances that can vary by up to several hundred percent. These data illustrate that the interpretation of comparatively small differences in capacitance for different types of solid contacts is not meaningful unless the composition of the ion-selective membrane is taken into account.
Collapse
|
7
|
Influence of the Composition of Plasticizer-Free Silicone-Based Ion-Selective Membranes on Signal Stability in Aqueous and Blood Plasma Samples. Anal Chem 2023; 95:12419-12426. [PMID: 37552138 DOI: 10.1021/acs.analchem.3c02074] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) in direct long-term contact with physiological samples must be biocompatible and resistant to biofouling, but most wearable SC-ISEs proposed to date contain plasticized poly(vinyl chloride) (PVC) membranes, which have poor biocompatibility. Silicones are a promising alternative to plasticized PVC because of their excellent biocompatibility, but little work has been done to study the relationship between silicone composition and ISE performance. To address this, we prepared and tested K+ SC-ISEs with colloid-imprinted mesoporous (CIM) carbon as the solid contact and three different condensation-cured silicones: a custom silicone prepared in-house (Silicone 1), a commercial silicone (Dow 3140, Silicone 2), and a commercial fluorosilicone (Dow 730, Fluorosilicone 1). SC-ISEs prepared with each of these polymers and the ionophore valinomycin and added ionic sites exhibited Nernstian responses, excellent selectivities, and signal drifts as low as 3 μV/h in 1 mM KCl solution. All ISEs maintained Nernstian response slopes and had only very slightly worsened selectivities after 41 h exposure to porcine plasma (log KK,Na values of -4.56, -4.58, and -4.49, to -4.04, -4.00, and -3.90 for Silicone 1, Silicone 2, and Fluorosilicone 1, respectively), confirming that these sensors retain the high selectivity that makes them suitable for use in physiological samples. When immersed in porcine plasma, the SC-ISEs exhibited emf drifts that were still fairly low but notably larger than when measurements were performed in pure water. Interestingly, despite the very similar structures of these matrix polymers, SC-ISEs prepared with Silicone 2 showed lower drift in porcine blood plasma (-55 μV/h, over 41 h) compared to Silicone 1 (-495 μV/h) or Fluorosilicone 1 (-297 μV/h).
Collapse
|
8
|
Ion-Selective Electrodes With Sensing Membranes Covalently Attached to Both the Inert Polymer Substrate and Conductive Carbon Contact. Angew Chem Int Ed Engl 2023:e202304674. [PMID: 37166178 DOI: 10.1002/anie.202304674] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/10/2023] [Accepted: 05/11/2023] [Indexed: 05/12/2023]
Abstract
The use of solid-contact ion-selective electrodes (ISEs) is of interest to many clinical, environmental, and industrial applications. However, upon extended exposure to samples and under thermal and mechanical stress, adhesion between these membranes and underlying substrates often weakens gradually. Eventually, this results in the formation of a water layer at the interface to the underlying electron conductor and in delamination of the membrane from the electrode body, both major limitations to long-term monitoring. To prevent these problems without increasing the complexity of design with a mechanical attachment, we use photo-induced graft polymerization to simultaneously attach ionophore-doped crosslinked poly(decyl methacrylate) sensing membranes covalently both to a high surface area carbon as ion-to-electron transducer and to inert polymeric electrode body materials (i.e., polypropylene and poly(ethylene-co-tetrafluoroethylene)). The sensors provide high reproducibility (standard deviation of E0 of 0.2 mV), long-term stability (potential drift 7 µV/h over 260 h), and resistance to sterilization in an autoclave (121 °C, 2.0 atm for 30 min). For this work, a covalently attached H+ selective ionophore was used to prepare pH sensors with advantages over conventional pH glass electrodes, but similar use of other ionophores makes this approach suitable to the fabrication of ISEs for a variety of analytes.
Collapse
|
9
|
Spontaneous Mesoporosity-Driven Sequestration of Ionic Liquids from Silicone-Based Reference Electrode Membranes. ACS Sens 2023; 8:1774-1781. [PMID: 37043696 DOI: 10.1021/acssensors.3c00085] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
Nanopore-driven sequestration of ionic liquids from a silicone membrane is presented, a phenomenon that has not been reported previously. Reference electrodes with ionic liquid doped polydimethylsiloxane (PDMS) reference membranes and colloid-imprinted mesoporous carbon (CIM) as solid contact are not functional unless special attention is paid to the porosity of the solid contact. In the fabrication of such reference electrodes, a solution of a hydroxyl-terminated silicone oligomer, ionic liquid, cross-linking reagent, and polymerization catalyst is deposited on top of the carbon layer, rapidly filling the pores of the CIM carbon. The catalyzed polymerization curing of the silicone quickly results in cross-linking of the hydroxyl-terminated polydimethylsiloxane oligomers, forming structures that are too large to penetrate the CIM carbon pores. Therefore, as solvent evaporation from the top of freshly prepared membranes drives the diffusional transport of solvent toward that membrane surface, the solvent molecules that leave the CIM carbon pores can only be replaced by the ionic liquid. This depletes the ionic liquid in the reference membrane that overlies the CIM carbon solid contact and increases the membrane resistance by up to 3 orders of magnitude, rendering the devices dysfunctional. This problem can be avoided by presaturating the CIM carbon with ionic liquid prior to the deposition of the solution that contains the silicone oligomers and ionic liquid. Alternatively, a high amount of ionic liquid can be added into the membrane solution to account for the size-selective sequestration of ionic liquid into the carbon pores. Either way, a wide variety of ionic liquids can be used to prepare PDMS-based reference electrodes with CIM carbon as a solid contact. A similar depletion of the K+ ionophore BME-44 from ion-selective silicone membranes was observed too, highlighting that the depletion of active ingredients from polymeric ion-selective and reference membranes due to interactions with high surface area solid contacts may be a more common phenomenon that so far has been overlooked.
Collapse
|
10
|
Machine Learning-Based Rapid Detection of Volatile Organic Compounds in a Graphene Electronic Nose. ACS NANO 2022; 16:19567-19583. [PMID: 36367841 DOI: 10.1021/acsnano.2c10240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Rapid detection of volatile organic compounds (VOCs) is growing in importance in many sectors. Noninvasive medical diagnoses may be based upon particular combinations of VOCs in human breath; detecting VOCs emitted from environmental hazards such as fungal growth could prevent illness; and waste could be reduced through monitoring of gases produced during food storage. Electronic noses have been applied to such problems, however, a common limitation is in improving selectivity. Graphene is an adaptable material that can be functionalized with many chemical receptors. Here, we use this versatility to demonstrate selective and rapid detection of multiple VOCs at varying concentrations with graphene-based variable capacitor (varactor) arrays. Each array contains 108 sensors functionalized with 36 chemical receptors for cross-selectivity. Multiplexer data acquisition from 108 sensors is accomplished in tens of seconds. While this rapid measurement reduces the signal magnitude, classification using supervised machine learning (Bootstrap Aggregated Random Forest) shows excellent results of 98% accuracy between 5 analytes (ethanol, hexanal, methyl ethyl ketone, toluene, and octane) at 4 concentrations each. With the addition of 1-octene, an analyte highly similar in structure to octane, an accuracy of 89% is achieved. These results demonstrate the important role of the choice of analysis method, particularly in the presence of noisy data. This is an important step toward fully utilizing graphene-based sensor arrays for rapid gas sensing applications from environmental monitoring to disease detection in human breath.
Collapse
|
11
|
The Effect of Paper on the Detection Limit of Paper-Based Potentiometric Chloride Sensors. Anal Chem 2022; 94:14898-14905. [PMID: 36260770 DOI: 10.1021/acs.analchem.2c02261] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
While paper is an excellent material for use in many other portable sensors, potentiometric paper-based sensors have been reported to perform worse than conventional rod-shaped electrodes, in particular in view of limits of detection (LODs). Reported here is an in-depth study of the lower LOD for Cl- measurements with paper-based devices comprising AgCl/Ag transducers. Contamination by Cl- from two commonly used device materials─a AgCl/Ag ink and so-called ashless filter paper─was found to increase the concentration of Cl- in paper-contained samples far above what is expected for the spontaneous dissolution of the transducer's AgCl, thereby worsening lower LODs. In addition, for the case of Ag+, the commonly hypothesized adsorption of metal cations onto filter paper was found not to significantly affect the performance of AgCl/Ag transducers. We note that in the context of chemical analysis, metal impurities of paper are often mentioned in the literature, but Cl- contamination of paper has been overlooked.
Collapse
|
12
|
Seeded Binary Segmentation: A general methodology for fast and optimal changepoint detection. Biometrika 2022. [DOI: 10.1093/biomet/asac052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Summary
We propose seeded binary segmentation for large scale changepoint detection problems. We construct a deterministic set of background intervals, called seeded intervals, in which single changepoint candidates are searched for. The final selection of changepoints based on these candidates can be done in various ways, adapted to the problem at hand. The method is thus easy to adapt to many changepoint problems, ranging from univariate to high-dimensional. Compared to recently popular random background intervals, seeded intervals lead to reproducibility and much faster computations. For the univariate Gaussian change in mean set-up, the methodology is shown to be asymptotically minimax optimal when paired with appropriate selection criteria. We demonstrate near-linear runtimes and competitive finite sample estimation performance. Furthermore, we illustrate the versatility of our method in high-dimensional settings.
Collapse
|
13
|
Comparison of the kinetics of aldehyde sensing by covalent bond formation with hydrazines and hydroxylamines. Tetrahedron 2022. [DOI: 10.1016/j.tet.2022.132852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
14
|
Solid-Contact pH Sensor with Covalent Attachment of Ionophores and Ionic Sites to a Poly(decyl methacrylate) Matrix. Anal Chem 2021; 93:16899-16905. [PMID: 34878238 DOI: 10.1021/acs.analchem.1c03985] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
With a view to improving the sensor lifetime, solid-contact ion-selective electrodes (ISEs) were prepared with a plasticizer-free and cross-linked poly(decyl methacrylate) matrix, to which only the ionic sites, only the ionophore, or both the ionic sites and ionophore were covalently attached. In earlier work with covalently attached ionophores or ionic sites, it was difficult to discount the presence of ionophores or ionic site impurities that were not covalently attached to the polymer backbone because the reagents used to introduce the ionophore or ionic sites had high hydrophobicities. In this work, we deliberately chose readily available hydrophilic reagents for the introduction of covalently attached H+ ionophores with tertiary amino groups and covalently attached sulfonate groups as ionic sites. This simplified the synthesis and made it possible to thoroughly remove ionophores and ionic sites not covalently attached to the polymer backbone. Our results confirm the expectation that hydrophobic ISE membranes with both covalently attached ionophores and ionic sites have impractically long response times. In contrast, ISEs with either covalently attached H+ ionophores or covalently attached ionic sites responded to pH with quick Nernstian responses and high selectivity. Both conventional plasticized poly(vinyl chloride) (PVC)-based ISEs and the new poly(decyl methacrylate) membranes were exposed to 90 °C heat for 2 h, 10% ethanol for 1 day, or undiluted blood serum for 5 days. In all three cases, the poly(decyl methacrylate) ISEs exhibited properties superior to conventional PVC-based ISEs, confirming the advantages of the covalent attachment.
Collapse
|
15
|
Hydrogels Doped with Redox Buffers as Transducers for Ion-Selective Electrodes. Anal Chem 2021; 94:1143-1150. [PMID: 34932309 DOI: 10.1021/acs.analchem.1c04264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Solid-contact ion-selective electrodes (ISEs) with an unintentional water layer between the sensing membrane and underlying electron conductor are well known to suffer from potential drift caused by the instability of the phase boundary potential between the sensing membrane and the water layer with its uncontrolled ionic composition. The reproducibility and long-term emf stability of ISEs with a miniaturized inner filling solution comprising a hydrogel and a hydrophilic electrolyte have not been studied as thoroughly. Here, such devices are discussed with a view to electrode-to-electrode reproducibility, using both hydrophilic ion-exchange and plasticized PVC membranes, along with a hydrophilic redox buffer composed of ferrocyanide and ferricyanide to control the potential between the hydrogel and the underlying electron conductor. With plasticized PVC sensing membranes, these electrodes showed an E0 reproducibility of ±1.1 mV or better, while with hydrophilic ion-exchange membranes, this variability was slightly larger. Long-term drifts were also assessed with both membranes, and the effect of osmotic pressure on drift was shown to be insignificant for the PVC membranes and very small at most for the hydrophilic membranes.
Collapse
|
16
|
Recent Progress in the Development of Improved Reference Electrodes for Electrochemistry. ANAL SCI 2021; 38:71-83. [PMID: 34866115 DOI: 10.2116/analsci.21sar11] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 11/26/2021] [Indexed: 11/23/2022]
|
17
|
|
18
|
Easy-to-Make Capillary-Based Reference Electrodes with Controlled, Pressure-Driven Electrolyte Flow. ACS Sens 2021; 6:2211-2217. [PMID: 34087074 DOI: 10.1021/acssensors.1c00065] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
As solid-contact potentiometric sensors based on novel materials have reached exceptional stabilities with drifts in the low μV/h range and long-term and calibration-free potentiometric measurements gain more and more attention, reference electrode designs that used to be satisfactory for most users do not satisfy the needs of new challenging applications. It is important that the interface between a reference electrode and the sample, often provided by a salt bridge, remains constant in ion composition over time. Excessive restriction of the flow of the bridge electrolyte, e.g., by using nanoporous frits or gelled reference electrolyte solutions, can result in contamination of the salt bridge with sample components and depletion of the reference electrolyte by diffusion into samples. This can be avoided by using salt bridges that flow freely into the sample. However, commonly used reference electrodes with free-flowing junctions often suffer either from experimental difficulties in assuring a minimum flow rate or from excessive flow rates that require frequent replenishing of the bridge electrolyte. To this end, we developed a reference electrode that contains a concentrated electrolyte contacting samples through a 10.2 μm capillary. By applying a minimal pressure of 10.0 kPa, a flow rate of 100 nL/h is achieved. This maintains a constant liquid junction potential at the interface with the sample and avoids contamination of the reference electrode, as evidenced by a potential stability of 6 ± 3 μV/h over 21 days. With such a minimal flow rate, there is no need to refill the reference electrode electrolyte for years.
Collapse
|
19
|
Correction to Fluorophilic Ionophores for Potentiometric pH Determinations with Fluorous Membranes of Exceptional Selectivity. Anal Chem 2020; 92:16338. [DOI: 10.1021/acs.analchem.0c04818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
20
|
Reference Electrodes Based on Ionic Liquid-Doped Reference Membranes with Biocompatible Silicone Matrixes. ACS Sens 2020; 5:1717-1725. [PMID: 32366104 DOI: 10.1021/acssensors.0c00363] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Many reference electrodes with an ionic liquid-doped reference membrane contain a plasticizer that can gradually leach out into the sample. However, because many common plasticizers are known to be endocrine disruptors and may induce inflammatory reactions, they are preferably avoided for wearable or implantable sensors. Therefore, this work tested polymeric reference electrode membranes prepared by solvent casting from seven commercially available biocompatible silicones that are widely used in implantable devices. Only reference electrodes with membranes consisting of poly(3,3,3-trifluoropropylmethylsiloxane) (Fluorosilicone 1) and one of several 1-methyl-3-alkylimidazolium bis(trifluoromethylsulfonyl)imide ionic liquids provided a stable and sample-independent potential in electrolyte solutions spanning the range of electrolyte concentrations in human blood, with more hydrophobic ionic liquids performing better. Over 8 days at 37 °C in artificial blood electrolyte solutions, the reference membranes doped with 1-methyl-3-octylimidazolium bis(trifluoromethylsulfonyl)imide exhibited a potential drift as low as 20 μV/h. In 10% animal serum, a 112 μV/h drift was observed over 5.8 days. The other six silicone materials doped with an ionic liquid either failed to form self-standing membranes or did not provide a sample-independent potential in the ionic concentration range tested. In case of the functional reference electrodes, differential scanning calorimetry confirmed good miscibility between the ionic liquid and the polymer matrix, whereas the poor miscibility of four polymer matrixes and the ionic liquids-as confirmed by differential scanning calorimetry-correlated with an undesirable sample dependence of the reference potential.
Collapse
|
21
|
Fluorous-Phase Ion-Selective pH Electrodes: Electrode Body and Ionophore Optimization for Measurements in the Physiological pH Range. ACS OMEGA 2020; 5:13621-13629. [PMID: 32566827 PMCID: PMC7301372 DOI: 10.1021/acsomega.0c00582] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Accepted: 05/18/2020] [Indexed: 06/11/2023]
Abstract
Because of their low polarity and polarizability, fluorous sensing membranes are both hydrophobic and lipophobic and exhibit very high ion selectivities. Here, we report on a new fluorous-membrane ion-selective electrode (ISE) with a wide sensing range centered around physiologically relevant pH values. The fluorophilic tris[perfluoro(octyl)butyl]amine (N[(CH2)4Rf8]3) was synthesized and tested as a new H+ ionophore using a redesigned electrode body that provides excellent mechanical sealing and much improved measurement reliability. In a challenging 1 M KCl background, these fluorous-phase ISEs exhibit a sensing range from pH 2.2 to 11.2, which is one of the widest working ranges reported to date for ionophore-based H+ ISEs. High selectivities against common interfering ions such as K+, Na+, and Ca2+ were determined (selectivity coefficients: logK H, K pot = - 11.6; logK H, Na pot = - 12.4; logK H, Ca pot < - 10.2). The use of the N[(CH2)4Rf8]3 ionophore with its -(CH2)4- spacers separating the amino group from the strongly electron-withdrawing perfluorooctyl groups improved the potentiometric selectivity as compared to the less basic tris[perfluoro(octyl)propyl]amine ionophore. The use of N[(CH2)4Rf8]3 also made the ISE less prone to counter anion failure (i.e., Donnan failure) at low pH than the use of tris[perfluoro(octyl)pentyl]amine with its longer -(CH2)5- spacers, which more effectively shield the amino center from the perfluorooctyl groups. In addition, we exposed both conventional plasticized PVC-phase pH ISEs and fluorous-phase pH ISEs to 10% serum for 5 days. Results show that the PVC-phase ISEs lost selectivity while their fluorous-phase counterparts did not.
Collapse
|
22
|
Solid-Contact Ion-Selective and Reference Electrodes Covalently Attached to Functionalized Poly(ethylene terephthalate). Anal Chem 2020; 92:7621-7629. [PMID: 32351106 DOI: 10.1021/acs.analchem.0c00296] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Numerous ion-selective and reference electrodes have been developed over the years. Following the need for point-of-care and wearable sensors, designs have transitioned recently from bulky devices with an aqueous inner filling solution to planarizable solid-contact electrodes. However, unless the polymeric sensing and reference membranes are held in place mechanically, delamination of these membranes from the underlying solid to which they adhere physically limits sensor lifetime. Even minor external mechanical stress or thermal expansion can result in membrane delamination and, thereby, device failure. To address this problem, we designed a sensing platform based on poly(ethylene terephthalate) substrates to which polyacrylate-based sensing and polymethacrylate-based reference membranes are attached covalently. Ion-selective membranes with covalently attached or freely dissolved ionophore- and ionic-liquid-doped reference membranes can be directly photopolymerized onto surface-functionalized poly(ethylene terephthalate), resulting in the formation of covalent bonds between the underlying substrate and the attached membranes. H+- and K+-selective electrodes thus prepared exhibit highly selective responses with the theoretically expected (Nernstian) response slope, and reference electrodes provide sample-independent reference potentials over a wide range of electrolyte concentrations. Even repeated mechanical stress does not result in the delamination of the sensing and reference membranes, leading to electrodes with much improved long-term performance. As demonstrated for poly(ethylene-co-cyclohexane-1,4-dimethanol terephthalate) (PETG), this approach may be expanded to a wide range of other polyester, polyamide, and polyurethane platform materials. Covalent attachment of sensing and reference membranes to an inert plastic platform material is a very promising approach to a problem that has plagued the field of ion-selective electrodes and field effect transistors for over 30 years.
Collapse
|
23
|
Critical Comparison of Reference Electrodes with Salt Bridges Contained in Nanoporous Glass with 5, 20, 50, and 100 nm Diameter Pores. ANAL SCI 2020; 36:187-191. [PMID: 31495816 DOI: 10.2116/analsci.19p235] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Porous glass frits are frequently used to contain the salt bridges through which reference electrodes interface samples. Prior work with widely used glass frits with 4 - 10 nm diameter pores showed that, when samples have a low electrolyte strength, electrostatic screening of sample ions by charged sites on the glass surface occurs. This creates an ion-specific phase-boundary potential at the interface between the sample and frit, and it biases the potential of the reference half-cell. Use of frits with much larger pores eliminates this problem but results in the need for frequent replenishing of the bridge electrolyte. A methodical study to determine the optimum pore size has been missing. We show here that charge screening of sample ions occurs when the pore size of nanoporous glass frits is on the order of 1 - 50 nm and samples have a low electrolyte strength. An increase in pores size to 100 nm eliminates charge screening in samples with ionic strengths in the 1.0 M to 3.3 × 10-4 M range. However, the rates of electrolyte solution flow through frits with 1, 5, 20, 50, and 100 nm pores are still low, which makes diffusion the dominant mode of ion transport into and out of these frits. Consequently, the flow of bridge electrolyte into samples is not fast enough to prevent diffusion of ions and electrically neutral components from the sample diffusing into the salt bridge, which can result in cross contamination among samples.
Collapse
|
24
|
Indirect Potentiometric Determination of Polyquaternium Polymer Concentrations by Equilibrium Binding to 1-Dodecyl Sulfate. ANAL SCI 2019; 35:679-684. [PMID: 30799313 DOI: 10.2116/analsci.18p567] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Polyquaternium polymers are polycationic polymers that are contained in many hair shampoos and conditioners and are also often added to water to remove organic and inorganic anions by floc formation. While polyquaternium analysis is not trivial, electroanalytical methods have been proposed for their detection using either irreversible emf responses or reversible potential-driven extraction into and out of polymeric sensing membranes. We present here an alternative technique for the determination of a representative polyquaternium polymer, poly(dimethylamine-co-epichlorohydrin) chloride, by equilibrium binding with a singly charged anionic surfactant, 1-dodecyl sulfate. Binding of an anionic surfactant to the polyquaternium polymer simplifies electrochemical detection as the concentration of unbound surfactant can be monitored using the equilibrium Nernstian emf response of ion-exchanger membranes. The latter can be used to determine the nature of the binding interaction and allows for the straightforward determination of polyquaternium polymer concentrations by titration.
Collapse
|
25
|
More than a Liquid Junction: Effect of Stirring, Flow Rate, and Inward and Outward Electrolyte Diffusion on Reference Electrodes with Salt Bridges Contained in Nanoporous Glass. Anal Chem 2019; 91:7698-7704. [DOI: 10.1021/acs.analchem.9b00876] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
26
|
Potentiometric Selectivities of Ionophore-Doped Ion-Selective Membranes: Concurrent Presence of Primary Ion or Interfering Ion Complexes of Multiple Stoichiometries. Anal Chem 2019; 91:2409-2417. [PMID: 30609363 DOI: 10.1021/acs.analchem.8b05196] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The selectivities of ionophore-doped ion-selective electrode (ISE) membranes are controlled by the stability and stoichiometry of the complexes between the ionophore, L, and the target and interfering ions (I zi and J zj, respectively). Well-accepted models predict how these selectivities can be optimized by selection of ideal ionophore-to-ionic site ratios, considering complex stoichiometries and ion charges. These models were developed for systems in which the target and interfering ions each form complexes of only one stoichiometry. However, for a few ISEs, the concurrent presence of two primary ion complexes of different stoichiometries, such as IL zi and IL2 zi, was reported. Indeed, similar systems were probably often overlooked and are, in fact, more common than the exclusive formation of complexes of higher stoichiometry unless the ionophore is used in excess. Importantly, misinterpreted stoichiometries misguide the design of new ionophores and are likely to result in the formulation of ISE membranes with inferior selectivities. We show here that the presence of two or more complexes of different stoichiometries for a given ion may be inferred experimentally from careful interpretation of the potentiometric selectivities as a function of the ionophore-to-ionic site ratio or from calculations of complex concentrations using experimentally determined complex stabilities. Concurrent formation of JL zj and JL2 zj complexes of an interfering ion is shown here to shift the ionophore-to-ionic site ratio that provides the highest selectivities. Formation of IL n-1 zi and IL n zi complexes of a primary ion is less of a concern because an optimized membrane typically contains an excess of ionophore, but lower than expected selectivities may be observed if the stepwise complex formation constant, KILn, is not sufficiently large and the ionophore-to-ionic site ratio does not markedly exceed n.
Collapse
|
27
|
Remediation of Perfluorooctylsulfonate Contamination by in Situ Sequestration: Direct Monitoring of PFOS Binding to Polyquaternium Polymers. ACS OMEGA 2019; 4:1068-1076. [PMID: 31459383 PMCID: PMC6648715 DOI: 10.1021/acsomega.8b03275] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Accepted: 12/10/2018] [Indexed: 05/29/2023]
Abstract
In situ methods for the sequestration of perfluorooctyl-1-sulfonate (PFOS) that are based on PFOS binding to polyquaternium polymers were reported previously, providing an approach to immobilize and concentrate PFOS in situ. To apply these methods in real life, the concentrations of polymers that permit efficient sequestration must be determined. This is only possible if the stoichiometry and strength of PFOS binding to polyquaternium polymers are known. Here, we report on the use of fluorous-phase ion-selective electrodes (ISEs) to determine the equilibrium constants characterizing binding of PFOS to poly(dimethylamine-co-epichlorohydrin) and poly(diallyldimethylammonium) in simulated groundwater and in soil suspensions. We introduce a new method to interpret potentiometric data for surfactant binding to the charged repeat unit of these polyions by combining a 1:1 binding model with the ISE response model. This allows for straightforward prediction and fitting of experimental potentiometric data in one step. Data fit the binding model for poly(diallyldimethylammonium) and poly(dimethylamine-co-epichlorohydrin) chloride in soil-free conditions and in the presence of soil from Tinker Air Force Base. When the total PFOS concentration in a soil system is known, knowledge of these PFOS binding characteristics permits quantitative prediction of the mobile (free) and polymer-bound fractions of PFOS as a function of the concentrations of the polyquaternium polymer. Because the technique reported here is based on the selective in situ determination of the free ionic surfactant, we expect it to be similarly useful for determining the sequestration of a variety of other ionic pollutants.
Collapse
|
28
|
Abstract
The neurotransmitter acetylcholine (ACh) plays a key role in the pathophysiology of brain disorders such as Alzheimer's disease. Understanding the dynamics of ACh concentration changes and kinetics of ACh degradation in the living brain is crucial to unravel the pathophysiology of such diseases and the rational design of therapeutics. In this work, an electrochemical sensor capable of dynamic, label-free, selective, and in situ detection of ACh in a range of 1 nM to 1 mM (with temporal resolution of less than one second) was developed. The sensor was employed for the direct detection of ACh in artificial cerebrospinal fluid and rat brain homogenate, without any prior separation steps. A potentiometric receptor-doped ion-selective electrode (ISE) with selectivity for ACh was designed by taking advantage of the positive charge of ACh. The dynamic range, limit of detection (LOD), and the selectivity of the sensor were optimized stepwise by (i) screening of hydrophobic biomimetic calixarenes to identify receptors that strongly bind to ACh based on shape-selective multitopic recognition, (ii) doping of the ISE sensing membrane with an ACh-binding hydrophobic calixarene to enable selective detection of ACh in complex matrices, (iii) utilizing a hydrophilic calixarene in the inner filling solution of the ISE to buffer the concentration of ACh and, thereby, lower the LOD of the sensor, and (iv) introducing a surface treatment step prior to the measurement by placing the sensor for ∼1 min in a solution of a hydrophilic calixarene to lower the LOD of the sensor even further.
Collapse
|
29
|
Redox Buffer Capacity of Ion-Selective Electrode Solid Contacts Doped with Organometallic Complexes. Anal Chem 2018; 90:11000-11007. [DOI: 10.1021/acs.analchem.8b02595] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
30
|
Discussion of “The Evolution of Boosting Algorithms” and “Extending Statistical Boosting”. Methods Inf Med 2018; 53:436-45. [DOI: 10.3414/13100122] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
SummaryThis article is part of a For-Discussion-Section of Methods of Information in Medicine about the papers “The Evolution of Boosting Algorithms – From Machine Learning to Statistical Modelling” [1] and “Extending Statistical Boosting – An Overview of Recent Methodological Developments” [2], written by Andreas Mayr and co-authors. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the Mayr et al. papers. In sub-sequent issues the discussion can continue through letters to the editor.
Collapse
|
31
|
Capacitive Sensing of Glucose in Electrolytes Using Graphene Quantum Capacitance Varactors. ACS APPLIED MATERIALS & INTERFACES 2017; 9:38863-38869. [PMID: 29023095 DOI: 10.1021/acsami.7b14864] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
A novel graphene-based variable capacitor (varactor) that senses glucose based on the quantum capacitance effect was successfully developed. The sensor utilizes a metal-oxide-graphene varactor device structure that is inherently compatible with passive wireless sensing, a key advantage for in vivo glucose sensing. The graphene varactors were functionalized with pyrene-1-boronic acid (PBA) by self-assembly driven by π-π interactions. Successful surface functionalization was confirmed by both Raman spectroscopy and capacitance-voltage characterization of the devices. Through glucose binding to the PBA, the glucose concentration in the buffer solutions modulates the level of electrostatic doping of the graphene surface to different degrees, which leads to capacitance changes and Dirac voltage shifts. These responses to the glucose concentration were shown to be reproducible and reversible over multiple measurement cycles, suggesting promise for eventual use in wireless glucose monitoring.
Collapse
|
32
|
Self-Supporting, Hydrophobic, Ionic Liquid-Based Reference Electrodes Prepared by Polymerization-Induced Microphase Separation. ACS Sens 2017; 2:1498-1504. [PMID: 28944667 DOI: 10.1021/acssensors.7b00512] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Interfaces of ionic liquids and aqueous solutions exhibit stable electrical potentials over a wide range of aqueous electrolyte concentrations. This makes ionic liquids suitable as bridge materials that separate in electroanalytical measurements the reference electrode from samples with low and/or unknown ionic strengths. However, methods for the preparation of ionic liquid-based reference electrodes have not been explored widely. We have designed a convenient and reliable synthesis of ionic liquid-based reference electrodes by polymerization-induced microphase separation. This technique allows for a facile, single-pot synthesis of ready-to-use reference electrodes that incorporate ion conducting nanochannels filled with either 1-octyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-dodecyl-3-methylimidazolium bis(trifluoromethyl sulfonyl)imide as ionic liquid, supported by a mechanically robust cross-linked polystyrene phase. This synthesis procedure allows for the straightforward design of various reference electrode geometries. These reference electrodes exhibit a low resistance as well as good reference potential stability and reproducibility when immersed into aqueous solutions varying from deionized, purified water to 100 mM KCl, while requiring no correction for liquid junction potentials.
Collapse
|
33
|
Cleaning of pH Selective Electrodes with Ionophore‐doped Fluorous Membranes in NaOH Solution at 90 °C. ELECTROANAL 2017. [DOI: 10.1002/elan.201700228] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
34
|
|
35
|
Abstract
Potentiometric selectivities show that in fluorous ion-selective electrode membranes the tetrabutylammonium ion binds to fluorophilic proton ionophores. For the ionophore bis[3-(perfluorooctyl)propyl](2,2,2-trifluoroethyl)amine, this type of interaction is confirmed by the effect of the ionophore on the ionic conductivity of perfluoro(perhydrophenanthrene) solutions of a fluorophilic NBu4+ salt. In this system, ion pairs, triple ions, and higher ionic aggregates dominate over single ions, and the ionophore increases the conductivity by favoring the formation of ion aggregates with a net charge. These observations are consistent with the formation of R3N+-C(R)-H···NR3 type hydrogen bonds between the nitrogen atom of the ionophore and the hydrogen atoms in the α position to the positively charged quaternary ammonium center of NBu4+. Similar interactions were observed in a number of crystalline phases. To date, observations of C-H···N type hydrogen bonds in liquid phases have been very few, and solution-phase N+-C-H···N type hydrogen bonds have not been reported previously. Interestingly, no interactions between NBu4+ and the more basic ionophore tridodecylamine were observed in conventional plasticized poly(vinyl chloride) membranes doped with the ionophore tridodecylamine, emphasizing the uniquely low polarity of fluorous phases.
Collapse
|
36
|
Electrochemical Impedance Spectroscopy of Ion-Selective Membranes: Artifacts in Two-, Three-, and Four-Electrode Measurements. Anal Chem 2016; 88:9738-9745. [DOI: 10.1021/acs.analchem.6b02641] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
37
|
Avoiding Errors in Electrochemical Measurements: Effect of Frit Material on the Performance of Reference Electrodes with Porous Frit Junctions. Anal Chem 2016; 88:8706-13. [DOI: 10.1021/acs.analchem.6b02025] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
38
|
A Disposable Planar Paper-Based Potentiometric Ion-Sensing Platform. Angew Chem Int Ed Engl 2016; 55:7544-7. [DOI: 10.1002/anie.201603017] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2016] [Indexed: 11/08/2022]
|
39
|
|
40
|
One-dimensional ionic self-assembly in a fluorous solution: the structure of tetra-n-butylammonium tetrakis[3,5-bis(perfluorohexyl)phenyl]borate in perfluoromethylcyclohexane by small-angle neutron scattering (SANS). Phys Chem Chem Phys 2016; 18:9470-5. [PMID: 26980055 DOI: 10.1039/c6cp00393a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Fluorous liquids are the least polarizable condensed phases known, and their nonpolar members form solutions with conditions the closest to being in vacuo. A soluble salt consisting of a large fluorophilic anion, tetrakis[3,5-bis(perfluorohexyl)phenyl]borate, and its counterion, tetra-n-butylammonium, dissolved in perfluoromethylcyclohexane produces ionic solutions with extremely low conductivity. These solutions were subjected to small-angle neutron scattering (SANS) to ascertain the solute structure. At concentrations of 9% mass fraction, the fluorophilic electrolyte forms straight, long (>160 Å) self-assembled structures that are, in essence, long, homogeneous cylinders. Molecular models were made assuming a requirement for electroneutrality on the shortest length scale possible. This shows a structure formed from a stack of alternating anions and cations, and the structures fit the experimental scattering well. At the lower concentration of 1%, the stacks of ion pairs are shorter and eventually break up to form solitary ion pairs in the solution. These characteristics suggest such conditions provide an interesting new way to form long, self-assembling ionic nanostructures with single-molecule diameters in free solution onto which various moieties could be attached.
Collapse
|
41
|
Ionic Liquids as Electrolytes for Electrochemical Double-Layer Capacitors: Structures that Optimize Specific Energy. ACS APPLIED MATERIALS & INTERFACES 2016; 8:3396-406. [PMID: 26771378 DOI: 10.1021/acsami.5b11353] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Key parameters that influence the specific energy of electrochemical double-layer capacitors (EDLCs) are the double-layer capacitance and the operating potential of the cell. The operating potential of the cell is generally limited by the electrochemical window of the electrolyte solution, that is, the range of applied voltages within which the electrolyte or solvent is not reduced or oxidized. Ionic liquids are of interest as electrolytes for EDLCs because they offer relatively wide potential windows. Here, we provide a systematic study of the influence of the physical properties of ionic liquid electrolytes on the electrochemical stability and electrochemical performance (double-layer capacitance, specific energy) of EDLCs that employ a mesoporous carbon model electrode with uniform, highly interconnected mesopores (3DOm carbon). Several ionic liquids with structurally diverse anions (tetrafluoroborate, trifluoromethanesulfonate, trifluoromethanesulfonimide) and cations (imidazolium, ammonium, pyridinium, piperidinium, and pyrrolidinium) were investigated. We show that the cation size has a significant effect on the electrolyte viscosity and conductivity, as well as the capacitance of EDLCs. Imidazolium- and pyridinium-based ionic liquids provide the highest cell capacitance, and ammonium-based ionic liquids offer potential windows much larger than imidazolium and pyridinium ionic liquids. Increasing the chain length of the alkyl substituents in 1-alkyl-3-methylimidazolium trifluoromethanesulfonimide does not widen the potential window of the ionic liquid. We identified the ionic liquids that maximize the specific energies of EDLCs through the combined effects of their potential windows and the double-layer capacitance. The highest specific energies are obtained with ionic liquid electrolytes that possess moderate electrochemical stability, small ionic volumes, low viscosity, and hence high conductivity, the best performing ionic liquid tested being 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide.
Collapse
|
42
|
|
43
|
Potentiometric in Situ Monitoring of Anions in the Synthesis of Copper and Silver Nanoparticles Using the Polyol Process. ACS NANO 2015; 9:12104-12114. [PMID: 26580413 DOI: 10.1021/acsnano.5b05170] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Potentiometric sensors, such as polymeric membrane, ion-selective electrodes (ISEs), have been used in the past to monitor a variety of chemical processes. However, the use of these sensors has traditionally been limited to aqueous solutions and moderate temperatures. Here we present an ISE with a high-capacity ion-exchange sensing membrane for measurements of nitrate and nitrite in the organic solvent propylene glycol at 150 °C. It is capable of continuously measuring under these conditions for over 180 h. We demonstrate the usefulness of this sensor by in situ monitoring of anion concentrations during the synthesis of copper and silver nanoparticles in propylene glycol using the polyol method. Ion chromatography and a colorimetric method were used to independently confirm anion concentrations measured in situ. In doing so, it was shown that in this reaction the co-ion nitrate is reduced to nitrite.
Collapse
|
44
|
Dynamic silver speciation as studied with fluorous-phase ion-selective electrodes: Effect of natural organic matter on the toxicity and speciation of silver. THE SCIENCE OF THE TOTAL ENVIRONMENT 2015; 537:453-461. [PMID: 26284896 PMCID: PMC4643687 DOI: 10.1016/j.scitotenv.2015.07.151] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 07/30/2015] [Accepted: 07/30/2015] [Indexed: 05/31/2023]
Abstract
The widespread application of silver in consumer products and the resulting contamination of natural environments with silver raise questions about the toxicity of Ag(+) in the ecosystem. Natural organic matter, NOM, which is abundant in water supplies, soil, and sediments, can form stable complexes with Ag(+), altering its bioavailability and toxicity. Herein, the extent and kinetics of Ag(+) binding to NOM, matrix effects on Ag(+) binding to NOM, and the effect of NOM on Ag(+) toxicity to Shewanella oneidensis MR-1 (assessed by the BacLight viability assay) were quantitatively studied with fluorous-phase Ag(+) ion-selective electrodes (ISEs). Our findings show fast kinetics of Ag(+) and NOM binding, weak Ag(+) binding for Suwannee River humic acid, fulvic acid, and aquatic NOM, and stronger Ag(+) binding for Pony Lake fulvic acid and Pahokee Peat humic acid. We quantified the effects of matrix components and pH on Ag(+) binding to NOM, showing that the extent of binding greatly depends on the environmental conditions. The effect of NOM on the toxicity of Ag(+) does not correlate with the extent of Ag(+) binding to NOM, and other forms of silver, such as Ag(+) reduced by NOM, are critical for understanding the effect of NOM on Ag(+) toxicity. This work also shows that fluorous-phase Ag(+) ISEs are effective tools for studying Ag(+) binding to NOM because they can be used in a time-resolved manner to monitor the activity of Ag(+) in situ with high selectivity and without the need for extensive sample preparation.
Collapse
|
45
|
Donnan Failure of Ion-Selective Electrodes with Hydrophilic High-Capacity Ion-Exchanger Membranes. ACS Sens 2015. [DOI: 10.1021/acssensors.5b00128] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
46
|
Hierarchically Porous Polymer Monoliths by Combining Controlled Macro- and Microphase Separation. J Am Chem Soc 2015; 137:8896-9. [DOI: 10.1021/jacs.5b04992] [Citation(s) in RCA: 114] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
47
|
Effects of Humic and Fulvic Acids on Silver Nanoparticle Stability, Dissolution, and Toxicity. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:8078-86. [PMID: 26047330 PMCID: PMC4643692 DOI: 10.1021/acs.est.5b01496] [Citation(s) in RCA: 144] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The colloidal stability of silver nanoparticles (AgNPs) in natural aquatic environments influences their transport and environmental persistence, while their dissolution to Ag(+) influences their toxicity to organisms. Here, we characterize the colloidal stability, dissolution behavior, and toxicity of two industrially relevant classes of AgNPs (i.e., AgNPs stabilized by citrate or polyvinylpyrrolidone) after exposure to natural organic matter (NOM, i.e., Suwannee River Humic and Fulvic Acid Standards and Pony Lake Fulvic Acid Reference). We show that NOM interaction with the nanoparticle surface depends on (i) the NOM's chemical composition, where sulfur- and nitrogen-rich NOM more significantly increases colloidal stability, and (ii) the affinity of the capping agent for the AgNP surface, where nanoparticles with loosely bound capping agents are more effectively stabilized by NOM. Adsorption of NOM is shown to have little effect on AgNP dissolution under most experimental conditions, the exception being when the NOM is rich in sulfur and nitrogen. Similarly, the toxicity of AgNPs to a bacterial model (Shewanella oneidensis MR-1) decreases most significantly in the presence of sulfur- and nitrogen-rich NOM. Our data suggest that the rate of AgNP aggregation and dissolution in aquatic environments containing NOM will depend on the chemical composition of the NOM, and that the toxicity of AgNPs to aquatic microorganisms is controlled primarily by the extent of nanoparticle dissolution.
Collapse
|
48
|
All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices. Anal Chem 2015; 87:2981-7. [DOI: 10.1021/ac504556s] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
49
|
Abstract
This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of chloride ions include wax-defined sample and reference zones that each incorporate a Ag/AgCl electrode. In EPADs developed for other electrolytes (potassium, sodium, and calcium ions), a PVC-based ion-selective membrane is added to separate the sample zone from a paper indicator electrode. After the addition of a small volume (less than 10 μL) of sample and reference solutions to different zones, ion-sensing EPADs exhibit a linear response, over 3 orders of magnitude, in ranges of electrolyte concentrations that are relevant to a variety of applications, with a slope close to the theoretical value (59.2/z mV). Ion-selective EPADs provide a portable, inexpensive, and disposable way of measuring concentrations of electrolyte ions in aqueous solutions.
Collapse
|
50
|
Ionic Liquid Reference Electrodes With a Well-Controlled Co(II)/Co(III) Redox Buffer as Solid Contact. ELECTROANAL 2014. [DOI: 10.1002/elan.201400274] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|