1
|
Jung MK, Jeon MJ, Kim JH, Son SA, Park JK, Seo DG. Comparison of the stress distribution in base materials and thicknesses in composite resin restorations. Heliyon 2024; 10:e25040. [PMID: 38333812 PMCID: PMC10850536 DOI: 10.1016/j.heliyon.2024.e25040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 01/17/2024] [Accepted: 01/18/2024] [Indexed: 02/10/2024] Open
Abstract
Resin-based composite materials are commonly used for restorations, but their dimensional changes during the polymerization could cause various clinical problems. This study evaluated the influence of a base of different materials and thicknesses on the stress magnitude and distribution in a second maxillary premolar with an MOD resin composite restoration using three-dimensional finite element analysis. A sound tooth without cavity was considered as the control group (ST), and another group was restored with composite resin without applying a base material in a MOD cavity (CR). The other three groups were restored with composite resin along with the following base materials: glass ionomer cement, low-viscosity resin, and tricalcium silicate, respectively (CR-GIC, CR-LR, and CR-TS). These three groups were further divided into two subgroups according to the thickness of the base layer: thin (0.5 mm) and thick (1.0 mm). The stress distribution was compared using the maximum principal stress after polymerization shrinkage and vertical loading with 600 N on the occlusal surface. Group ST showed the lowest stress value, and its stress propagation was confined to outer enamel surfaces only. Group CR demonstrated the highest stress distribution in the tooth-restoration interface with increased failure risk on marginal areas. The thin and thick subgroups of the three groups with a base layer had lower stress levels than Group CR. The base materials reduced the marginal stress caused by polymerization shrinkage of composite resin in MOD cavities. Different base materials and thicknesses did not affect the stress distribution.
Collapse
Affiliation(s)
- Min-Kwan Jung
- Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Mi-Jeong Jeon
- Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
- Department of Conservative Dentistry, College of Dentistry, Gangnam Severance Hospital, Yonsei University, Seoul, Republic of Korea
| | - Jae-Hoon Kim
- Department of Dental Education, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Deog-Gyu Seo
- Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
2
|
Son SA, Kim JH, Park JK. Clinical applications of a quantitative light-induced fluorescent (QLF) device in the detection and management of cracked teeth: A case report. Photodiagnosis Photodyn Ther 2023; 43:103735. [PMID: 37544373 DOI: 10.1016/j.pdpdt.2023.103735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/17/2023] [Accepted: 08/04/2023] [Indexed: 08/08/2023]
Abstract
INTRODUCTION The aim of this case report was to discuss the clinical application using a quantitative light-induced fluorescent (QLF) device for the diagnosis and treatment of a cracked tooth as visualizing the tooth's crack. CASE REPORT A 39-year-old woman visited a dental hospital complaining of throbbing pain on tooth #36. Observation of the tooth with naked eyes showed that tooth had a ceramic restoration with no specific findings. QLF device's images around the restoration, and after removal of the restoration were taken. In the QLF image after removal of the restoration, clear red-fluorescent crack line was shown, indicating that microorganism had penetrated along the crack path. During root canal treatment, the QLF image of the inside of the pulp chamber showed a pattern in which the crack line progressed into the tooth. During the treatment of the cracked tooth, the crack line was removed as much as possible using the fluorescent information obtained by the QLF device, and crack lines of fluorescence images quantitatively analyzed using a QLF's software. CONCLUSION Images acquired with the QLF device can provide useful information for detecting crack lines, recording the treatment process, and restorative management of cracked teeth.
Collapse
Affiliation(s)
- Sung-Ae Son
- Department of Conservative Dentistry, Dental and Life Science Institute, Dental Research Institute, School of Dentistry, Pusan National University, Geumo-ro 20, Mulgeum-eup, Box 50612, Yangsan, Republic of Korea
| | - Jae-Hoon Kim
- Department of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Dental and Life Science Institute, Dental Research Institute, School of Dentistry, Pusan National University, Geumo-ro 20, Mulgeum-eup, Box 50612, Yangsan, Republic of Korea.
| |
Collapse
|
3
|
Park Y, Kim JH, Park JK, Son SA. Scanning accuracy of an intraoral scanner according to different inlay preparation designs. BMC Oral Health 2023; 23:515. [PMID: 37488581 PMCID: PMC10367335 DOI: 10.1186/s12903-023-03233-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 07/17/2023] [Indexed: 07/26/2023] Open
Abstract
BACKGROUND The accuracy of intraoral scanning plays a crucial role in the workflow of computer-assisted design/computer-assisted manufacturing. However, data regarding scanning accuracy for inlay preparation designs are lacking. The purpose of this in vitro study was to evaluate the influence of the depth of the occlusal cavity and width of the gingival floor of the proximal box on the trueness and precision of intraoral scans for inlay restoration. METHODS Artificial teeth were used in this study. Four types of preparations for mesio-occlusal inlay were performed on each #36 artificial tooth depending on two different depths of the occlusal cavity (1 mm and 2 mm) and widths of the gingival floor of the proximal box (1.5 mm and 2.5 mm). Artificial teeth were scanned 10 times each with Cerec Primescan AC, and another scan was performed subsequently with a laboratory scanner as a reference (n = 10). Standard tessellation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using two-way analysis of variance and the Bonferroni multiple comparison test. RESULTS The narrow shallow group had significantly higher deviation values for trueness than the wide deep group (p < 0.05). The wide deep group had the lowest average deviation value for trueness and there was no significant difference between the narrow deep and wide shallow groups (p > 0.05). For the mean maximum positive deviation, the wide groups had significantly lower values than the narrow groups (p < 0.05). Trueness was affected by both the width and depth(p < 0.05), whereas the mean maximum positive deviation was affected by the width (p < 0.05). The mean maximum negative deviation was affected by all three factors (p < 0.05). Precision was affected by the depth and the interaction between the depth of the occlusal cavity and width of the gingival floor (p < 0.05). CONCLUSIONS The design of different inlay cavity configurations affected the accuracy of the digital intraoral scanner. The highest average deviation for trueness was observed in the narrow shallow group and the lowest in the wide deep group. With regard to precision, the narrow shallow group showed the lowest average deviation, and the narrow deep group showed highest value.
Collapse
Affiliation(s)
- Yeri Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jae-Hoon Kim
- Department of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Geumo-Ro 20, Mulgeum-Eup, Box 50612, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Geumo-Ro 20, Mulgeum-Eup, Box 50612, Yangsan, Republic of Korea.
| |
Collapse
|
4
|
Kim JH, Lee H, Son SA, Hong SJ, Park JK. Evaluation of the intaglio surface trueness and fit of zirconia crowns fabricated using different machining strategies with a chairside CAD/CAM system. Int J Comput Dent 2023; 0:0. [PMID: 36705318 DOI: 10.3290/j.ijcd.b3840499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
AIM This study aimed to evaluate the intaglio surface trueness and fit of zirconia crowns depending on the different machining strategies used with the CEREC system. MATERIALS AND METHODS Thirty duplicate tooth models for a single zirconia crown were randomly assigned to the three groups (n = 10) according to the machining mode used for fabrication: grinding, wet milling, and dry milling. The scan data of the final crowns were compared to their design data to evaluate the intaglio surface trueness. The marginal and internal fits were evaluated using the cross-sectional method. The time required for the machining and sintering processes was measured for each group. RESULT The wet milling group showed better trueness (RMS, 13.8 ± 1.0 μm) than the grinding and dry milling groups (p < 0.001). The marginal gap was greater in the grinding group (58.6 ± 28.9 μm) than that in the wet milling and dry milling groups (p < 0.001). The dry milling group required the shortest time for the manufacturing process. CONCLUSION All machining modes fabricated crowns with a clinically acceptable trueness and fit. However, the dry milling mode was advantageous for the chairside CAD/CAM system with respect to time efficiency.
Collapse
|
5
|
Son SA, Kim BN, Kim JH, Seo DG, Park JK. Influence of Dentin Surface Roughness, Drying Time, and Primer Application on Self-adhesive Composite-Cement Bond Strength. J Adhes Dent 2022; 24:137-146. [PMID: 35416441 DOI: 10.3290/j.jad.b2916387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE To investigate the effect of roughness and drying time of dentin as well as the number of coats of a self-adhesive composite-cement primer on the bond strength of self-adhesive composite cement. MATERIAL AND METHODS Sixty human teeth were prepared and assigned to 12 groups (n = 5), according to three experimental factors: 1) dentin surface roughness, rough or fine, as achieved by 250- and 600-grit silicon carbide papers, respectively; 2) dentin wetness based on air-drying time (5 or 10 s); and 3) the self-adhesive composite-cement primer applications (no-coat, 1-coat, and 2-coat). Composite resin blocks were made with hybrid composite resin (M1 GraceFil) and cemented with G-CEM ONE (both GC). Cement-dentin sticks (12) were prepared, and the microtensile bond strength (μTBS) test was performed. Failure modes were observed with a stereomicroscope (40X), and bonding interfaces were evaluated with confocal laser scanning microscopy (CLSM). Statistical analysis was performed using three-way ANOVA and Tukey's post-hoc comparisons test (α = 0.05). RESULTS Dentin roughness (250-grit > 600-grit, p = 0.000), drying time (5-s drying > 10-s drying, p = 0.000), and primer application (no-coat < 1-coat = 2-coat, p = 0.000) had significant effects on bond strength. These factors also showed significant interactions with each other (p = 0.003). The highest μTBS (31.8 ± 3.1 MPa) was observed in the 1-coat/fine roughness/10-s drying group and the lowest μTBS (13.4 ± 2.7 MPa) in the no-coat/coarse roughness/5-s drying group. CLSM showed higher penetration of cement in the primer-coated groups compared to that in the no-coat groups. CONCLUSION Bond strength between the self-adhesive composite cement and dentin was higher in the fine-roughness dentin group than in the coarse-roughness dentin group, and in the 5-s drying group compared to the 10-s drying group. Applying a primer to dentin improved bond strength of the self-adhesive composite cement.
Collapse
|
6
|
Kim BN, Son SA, Park JK. Endodontic retreatment of a calcified anterior tooth using a 3D-printed endodontic guide. Int J Comput Dent 2021; 24:419-427. [PMID: 34931777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The treatment of teeth with severely calcified canals is a difficult procedure for clinicians. Procedural accidents such as drill path deviation or perforation of the root canal often occur. 3D-printed directional guides made using CBCT and CAD/CAM can help the clinician to accurately drill in the original root canal direction. Furthermore, chairside operating times and excessive loss of tooth structure are reduced, and the risk of perforation is avoided. The present case report describes two cases of calcified root canals with path deviations that were retreated utilizing a guided endodontic technique.
Collapse
|
7
|
Kim JH, Son SA, Lee H, Yoo YJ, Hong SJ, Park JK. Influence of adjacent teeth on the accuracy of intraoral scanning systems for class II inlay preparation. J ESTHET RESTOR DENT 2021; 34:826-832. [PMID: 34608739 DOI: 10.1111/jerd.12824] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/17/2021] [Accepted: 09/20/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study aimed to evaluate the influence of the presence of adjacent teeth on the accuracy of intraoral scanning (IOS) systems for class II inlay preparation. MATERIALS AND METHODS The mesio-occlusal inlay preparation was prepared in an anatomical model of the maxillary molar. The prepared tooth was secured to a typodont with the mesial adjacent tooth removed or in situ. Ten digital impressions of the inlay preparation were acquired using three IOS systems (CEREC Primescan, 3Shape TRIOS 3, and Medit i500). A laboratory scanner (3Shape E3) was used to obtain the reference scan data. The mean absolute deviation values were calculated to evaluate the accuracy of the digital models. RESULTS The group with the adjacent teeth present showed lower trueness and precision compared to that without the adjacent tooth (p < .05). Significant differences were observed among the IOS systems (p < .05). Primescan showed the highest accuracy, irrespective of the presence of adjacent teeth. CONCLUSIONS The presence of the adjacent tooth negatively affected the accuracy of all the IOSs tested. Although the performance of Primescan was superior to that of TRIOS 3 and i500, each IOS system showed clinically acceptable levels of accuracy for class II inlay preparation. CLINICAL SIGNIFICANCE The adjacent tooth can be a confounding factor for accurate digital impressions of class II inlay preparation.
Collapse
Affiliation(s)
- Jae-Hoon Kim
- Department of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, South Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, South Korea
| | - Hyeonjong Lee
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, South Korea
| | - Yeon-Jee Yoo
- Department of Comprehensive Treatment Center, Seoul National University Dental Hospital, Seoul, South Korea
| | - Seoung-Jin Hong
- Department of Prosthodontics, School of Dentistry, Kyung Hee University, Seoul, South Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, South Korea
| |
Collapse
|
8
|
Son SA, Kim JH, Park JK. The Effectiveness of a Quantitative Light-induced Fluorescent Device for the Diagnosis of a Cracked Tooth: A Case Report. J Endod 2021; 47:1796-1800. [PMID: 34437880 DOI: 10.1016/j.joen.2021.08.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/03/2021] [Accepted: 08/16/2021] [Indexed: 12/29/2022]
Abstract
Diagnosing a cracked tooth is a challenge for dental clinicians. This report describes the use of a quantitative light-induced fluorescent (QLF) device that detects fluorescence reactions with visible light (405 nm) to visually identify microscopic tooth cracks during the diagnosis and treatment of cracked teeth that caused pulp disease. Fluorescence images of the occlusal surface, before and after removal of the restoration, and inside of the access cavity for root canal treatment were obtained using an intraoral capture-type QLF device (Q-ray penC; AIOBIO, Seoul, Korea). The device provided visual information such as enhanced magnification and fluorescent images to identify cracks on the exterior of the tooth, around restorations, and inside the cavity after removal of the restoration by a simple image capture process. The device was able to demonstrate the existence of the crack line and to predict the depth of cracks during treatment.The QLF device showed a potential benefit in the diagnosis and characterization, including the location and depth, of tooth cracks.
Collapse
Affiliation(s)
- Sung-Ae Son
- Department ofConservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jae-Hoon Kim
- Department ofDental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department ofConservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea.
| |
Collapse
|
9
|
Kim YR, Kim JH, Son SA, Park JK. Effect of Silane-Containing Universal Adhesives on the Bonding Strength of Lithium Disilicate. Materials (Basel) 2021; 14:ma14143976. [PMID: 34300895 PMCID: PMC8307548 DOI: 10.3390/ma14143976] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/20/2022]
Abstract
The purpose of this study was to investigate the effect of silane-containing universal adhesives on the bonding strength of lithium disilicate. Two-hundred-and-forty lithium disilicate blocks were divided into 16 groups according to the following surface treatments: hydrofluoric acid (HF)-treated or not, silane-treated or not, and the type of universal adhesive used (All-Bond Universal (ABU); Prime & bond (PB); Clearfil Universal Bond (CU); Single bond Universal (SBU)). After surface treatment, resin discs were bonded to each lithium disilicate using dual-cure resin cement. Bonded specimens were stored in distilled water for 24 h and then subjected to microtensile bond strength (μTBS) test. Failure modes were examined under stereomicroscope. Microscopic observation of bonded interfaces was analyzed using scanning electron microscopy. The μTBS data were statistically analyzed. Regardless of silane treatment, all groups treated with HF showed higher bonding strengths compared to those that were not treated with HF (p < 0.05). In groups treated with HF, the bonding strength increased after silane application (p < 0.05) except PB and CU (p > 0.05). Adhesive failures were dominant in all groups, but some mixed failures were observed in ABU treated with HF and silane. While most of the specimens that were not treated with silane after HF application only showed loose bonding between the ceramic and resin cement due to partial gaps, the specimens treated with silane application after HF showed a tight ceramic–resin interface. In conclusion, the silane in universal adhesives did not effectively improve the bonding strength between lithium disilicate and resin cement.
Collapse
Affiliation(s)
- Yu-Ri Kim
- Department of Conservative Dentistry, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-R.K.); (S.-A.S.)
| | - Jae-Hoon Kim
- Department of Dental Education, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea;
| | - Sung-Ae Son
- Department of Conservative Dentistry, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-R.K.); (S.-A.S.)
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Dental Research Institute, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-R.K.); (S.-A.S.)
- Correspondence: ; Tel.: +82-55-360-5221
| |
Collapse
|
10
|
Son SA, Kim JH, Seo DG, Park JK. Influence of different inlay configurations and distance from the adjacent tooth on the accuracy of an intraoral scan. J Prosthet Dent 2021; 128:680-687. [PMID: 33712313 DOI: 10.1016/j.prosdent.2020.12.044] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/22/2020] [Accepted: 12/22/2020] [Indexed: 10/21/2022]
Abstract
STATEMENT OF PROBLEM Clinical guidelines for obtaining accurate scan data during the intraoral scanning of inlay cavities with various configurations and interproximal distances are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of interproximal distance and cavity type on the accuracy of digital scans for inlay cavities, including proximal cavities. MATERIAL AND METHODS Four artificial teeth with 4 types of inlay cavities designed based on the buccolingual width and gingival level of the proximal box were installed in a mannequin at distances of 0.6, 0.8, and 1.0 mm from the adjacent teeth. Reference scans of the 4 artificial teeth were obtained by using a laboratory scanner. The CEREC Primescan AC was used to acquire digital scan data (each n=10). Standard tessellation language (STL) files were analyzed with a 3-dimensional analysis software program. The mean deviation values were measured with a 3-dimensional best-fit alignment method to evaluate the accuracy of the digital scan data. Statistical analyses were performed by using 2-way ANOVA and the Bonferroni multiple comparison test (α=.05). RESULTS As per the interproximal distance, the 1.0-mm group showed significantly higher trueness than the 0.6-mm group (P<.05). As the interproximal distance increased, the maximum positive deviation significantly decreased (P<.05). Maximum negative deviation and precision of the scan data were not significantly different among the distance groups (P>.05). Cavity type had a significant influence on the trueness and precision of the scan data (P<.05). In particular, the narrow long cavity type had an adverse effect on the precision and maximum positive deviation of scan data. CONCLUSIONS During the intraoral scanning of class II inlay restoration, interproximal distance and cavity type affected the accuracy of an intraoral scan. As the interproximal distance increased, the trueness of the acquired digital images increased and the maximum positive deviation significantly decreased. The narrow long cavity type negatively affected the mean maximum positive deviation and precision of scan data.
Collapse
Affiliation(s)
- Sung-Ae Son
- Associate Professor, Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jae-Hoon Kim
- Assistant Professor, Department of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Deog-Gyu Seo
- Professor, Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Republic of Korea
| | - Jeong-Kil Park
- Professor, Department of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea.
| |
Collapse
|
11
|
Kim JH, Son SA, Lee H, Kim RJY, Park JK. In vitro analysis of intraoral digital impression of inlay preparation according to tooth location and cavity type. J Prosthodont Res 2021; 65:400-406. [DOI: 10.2186/jpr.jpr_d_20_00169] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Jae-Hoon Kim
- Department of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Hyeonjong Lee
- Department of Prosthodontics, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Ryan Jin-Young Kim
- Department of Dental Science, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| |
Collapse
|
12
|
Lim GE, Son SA, Hur B, Park JK. Evaluation of the relationship between non-caries cervical lesions and the tooth and periodontal tissue: An ex-vivo study using micro-computed tomography. PLoS One 2020; 15:e0240979. [PMID: 33112900 PMCID: PMC7592738 DOI: 10.1371/journal.pone.0240979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 10/06/2020] [Indexed: 11/18/2022] Open
Abstract
The purpose of this study was to analyze the relationship between the height and depth of buccal non-carious cervical lesions (NCCLs) and the relationship between the size of buccal NCCLs and clinical crown-root ratio of both buccal and lingual (palatal) sides using micro-computed tomography (micro-CT) images of the teeth and periodontal tissues from the cadavers. The micro-CT images of 56 teeth and their supporting tissues were obtained from 17 cadavers. From these images, the height and depth of NCCLs and the length of the buccal and lingual (palatal) clinical crowns were measured, and the conventional/modified clinical crown-root ratios were calculated. The height and depth ratio of NCCLs were analyzed statistically with the conventional/modified crown-root ratios by Pearson's correlation and multiple regression. According to the Pearson's correlation, the height and depth of buccal NCCLs were positively correlated with the modified buccal clinical crown-root ratio (p < 0.001 and p = 0.013, respectively). The regression model composed of variables of crown-root ratios explained the height of buccal NCCLs, and the prominent factor of the model was the modified buccal clinical crown-root ratio (p < 0.001). Moreover, the depth of buccal NCCLs was also explained by the regression model, and its prominent factor was the proportion of modified buccal and lingual (palatal) clinical crowns (p = 0.004). The buccal NCCLs were related to the crown-root ratios; particularly, the level of buccal gingival margin could be associated with the formation of buccal NCCLs.
Collapse
Affiliation(s)
- Go-Eun Lim
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Bock Hur
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
- * E-mail:
| |
Collapse
|
13
|
Choi YJ, Bae MK, Kim YI, Park JK, Son SA. Effects of microsurface structure of bioactive nanoparticles on dentinal tubules as a dentin desensitizer. PLoS One 2020; 15:e0237726. [PMID: 32813737 PMCID: PMC7437925 DOI: 10.1371/journal.pone.0237726] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Accepted: 08/01/2020] [Indexed: 11/25/2022] Open
Abstract
In this in vitro study, spherical mesoporous bioactive glass nanoparticle (MBGN) and non-porous bioactive glass nanoparticle (BGN) were fabricated. The impact of mesopores on dentinal tubule occlusion and bioactivity was compared to examine the potential of these materials in alleviating dentine hypersensitivity (DH). MBGN, dense BGN were synthesized by sol-gel methods and characterized. Bioactivity and ion dissolution ability were analyzed. Twenty-four simulated sensitive dentin discs were prepared and randomly divided into three groups (n = 8 each); Group 1, no treatment; Group 2, Dense BGN; Group 3, MBGN. Then, four discs per group were treated with 6wt.% citric acid challenge to determine the acidic resistance. The effects on dentinal tubule occlusion were observed by FESEM. The microtensile bond strength (MTBS) was also measured. Cytotoxicity was examined using the MTT assay. According to the results, dense BGN without mesopore and MBGN with mesopore were successfully fabricated. Dense BGN and MBGN occluded the dentinal tubule before and after acid challenge. However, only MBGN formed a membrane-like layer and showed hydroxyapatite formation after soaking SBF solution. There were no significant differences in MTBS among dense BGN, MBGN (P>0.05). The cell viability was above 72% of both materials. The higher bioactivity of MBGN compared with that of dense BGN arises from the structural difference and it is anticipated to facilitate dentin remineralization by inducing hydroxyapatite deposition within the dentinal tubule.
Collapse
Affiliation(s)
- Yang-Jung Choi
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Gyeongsangnam-do, Korea
| | - Moon-Kyoung Bae
- Department of Oral Physiology, School of Dentistry, Pusan National University, Yangsan, Gyeongsangnam-do, Korea
| | - Yong-Il Kim
- Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Gyeongsangnam-do, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Gyeongsangnam-do, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Gyeongsangnam-do, Korea
- * E-mail:
| |
Collapse
|
14
|
Kim BN, Son SA, Park JK. Effect of Exclusive Primer and Adhesive on Microtensile Bond Strength of Self-Adhesive Resin Cement to Dentin. Materials (Basel) 2020; 13:ma13102353. [PMID: 32443843 PMCID: PMC7288079 DOI: 10.3390/ma13102353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/14/2020] [Accepted: 05/19/2020] [Indexed: 01/23/2023]
Abstract
The aim of this study was to investigate the effect of G-CEM One Primer (GCOP) and self-etching adhesive on the microtensile bond strength (µTBS) between self-adhesive resin cement G-CEM One (GCO) and dentin. Teeth were sectioned to expose the flat dentin surface and randomly assigned into five groups (n = 15) according to the dentin surface treatment: 1) no surface treatment, 2) GCOP, 3) All-Bond Universal (ABU), 4) GCOP followed by ABU (GCOP/ABU), 5) ABU followed by GCOP (ABU/GCOP). The composite resin blocks were bonded to the dentin surface using GCO. The specimens were stored in distilled water at 37 °C for 24 h, then sectioned into sticks (1 mm × 10 mm). The μTBS values were statistically analyzed using 1-way analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) test (α = 0.05) and failure mode was examined under a stereomicroscope. The bonding interface of each specimen was evaluated using confocal laser scanning microscopy. The GCOP group exhibited the highest µTBS value and there were no significant differences observed between GCOP, GCOP/ABU, ABU/GCOP groups (p > 0.05). The use of GCOP with GCO results in the improved µTBS between GCO and dentin. In conclusion, using only GCOP with GCO for bonding of indirect restoration is extremely simple and increasing bond strength.
Collapse
|
15
|
Son SA, Kim DH, Yoo KH, Yoon SY, Kim YI. Mesoporous Bioactive Glass Combined with Graphene Oxide Quantum Dot as a New Material for a New Treatment Option for Dentin Hypersensitivity. Nanomaterials (Basel) 2020; 10:nano10040621. [PMID: 32230884 PMCID: PMC7221916 DOI: 10.3390/nano10040621] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/25/2020] [Accepted: 03/26/2020] [Indexed: 11/16/2022]
Abstract
Dentin hypersensitivity is one of the most common clinical conditions usually associated with exposed dentinal tubules. The purpose of this study was to identify the potential of a graphene oxide quantum dot coating for mesoporous bioactive glass nanoparticles as a new material for the treatment of dentin hypersensitivity by investigating its mineralization activity and dentinal tubules sealing. Mesoporous bioactive glass nanoparticle was fabricated by modified sol-gel synthesis. X-ray diffraction was performed to characterize the synthesized nanoparticle Fourier transform infra-red spectroscopy investigated the functionalized surfaces. The distribution of the specific surface area and the pore size was measure by Pore size analysis. The morphology of sample was observed by Field Emission Scanning Electron Microscope (FESEM) and Field Emission Transmission Electron Microscope (FETEM). After disk-shaped specimens of mesoporous bioactive glass nanoparticles and graphene oxide quantum dot coated mesoporous bioactive glass nanoparticles (n = 3) were soaked in the simulated body fluid for 0, 1, 5, 10,and 30 days, the amount of ions released was observed to confirm the ionic elution for mineralization. Sensitive tooth model discs (n = 20) were applied with two samples and evaluated the dentinal tubule sealing ability. The spherical mesoporous bioactive glass nanoparticles and graphene oxide quantum dot coated mesoporous bioactive glass nanoparticles with a diameter of about 500 nm were identified through FESEM and FETEM. The ion release capacity of both samples appeared to be very similar. The amount of ion released and in vitro mineralization tests confirmed that graphene oxide quantum dot coating of mesoporous bioactive glass nanoparticles did not inhibit the release of calcium, silicon and phosphate ions, but rather that graphene oxide quantum dot promoted hydroxyapatite formation. In the FESEM image of the sensitive tooth disc surface, it was observed that graphene oxide quantum dot coated mesoporous bioactive glass nanoparticles sealed tightly the dentinal tubules. The graphene oxide quantum dot coating of mesoporous bioactive glass nanoparticles not only showed the excellent dentinal sealing ability but also rapidly promoted mineralization while minimizing the size increase by coating the mesoporous bioactive glass nanoparticles.
Collapse
Affiliation(s)
- Sung-Ae Son
- Department of Conservative Dentistry, Dental Research Institute, Pusan National University, Yangsan 50612, Korea
| | - Dong-Hyun Kim
- R&D Center, DAEWON MATERIALS Co., Ltd., 365, Sinseon-ro, Nam-gu, Busan, 48561, Korea;
| | - Kyung-Hyeon Yoo
- School of Materials Science and Engineering, Pusan National University, Busan 46241, Korea; (K.-H.Y.); (S.-Y.Y.)
| | - Seog-Young Yoon
- School of Materials Science and Engineering, Pusan National University, Busan 46241, Korea; (K.-H.Y.); (S.-Y.Y.)
| | - Yong-Il Kim
- Department of Orthodontics, Dental Research Institute, Pusan National University, Yangsan 50612, Korea
- Dental and Life Science Institute, Pusan National University, Yangsan 50612, Korea
- Correspondence: ; Tel.: +82-55-360-5163
| |
Collapse
|
16
|
Choi AN, Jang IS, Son SA, Jung KH, Park JK. Effect of erosive and abrasive stress on sealing ability of different desensitizers: In-vitro study. PLoS One 2019; 14:e0220823. [PMID: 31369650 PMCID: PMC6675100 DOI: 10.1371/journal.pone.0220823] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 07/23/2019] [Indexed: 11/30/2022] Open
Abstract
This in vitro study examined the sealing ability of different desensitizing agents under a chemo-mechanical stress condition. For the study, a total of 144 extracted, caries-free human third molars were used to produce 1 mm-thick dentin discs. The specimens were divided randomly into four groups: Superseal (SS), Gluma (GL), Gluma Self-etch (GS), and Tooth Coat (TC). For each group, the permeability was measured before and after applying the desensitizer, after being exposed to Coca Cola for 5 minutes, and after 3150 strokes of a brushing abrasion. The decrease in permeability after the erosive and abrasive stress was analyzed by ANOVA and Tukey post hoc test. As a result, the dentin permeability decreased significantly for all desensitizers immediately after application (p < 0.05). SS and GS showed a significant difference in permeability reduction observed immediately after application and after acid action with Coca Cola (p < 0.05). After brushing abrasion, the permeability reduction decreased significantly for all desensitizers tested in this study (p < 0.05). TC showed the largest decrease in dentinal permeability compared to that of the other desensitizers and the differences were significant after brushing abrasion (p < 0.05). All tested desensitizers were effective in reducing dentin permeability. The behavioral characteristics under erosive and abrasive stress varied according to the products used. TC exhibited excellent sealing ability among the other desensitizers.
Collapse
Affiliation(s)
- An-Na Choi
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Il-Seok Jang
- Department of Microbiology, School of Natural Sciences, Pusan National University, Busan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
- * E-mail:
| |
Collapse
|
17
|
Lee SM, Yoo KH, Yoon SY, Kim IR, Park BS, Son WS, Ko CC, Son SA, Kim YI. Enamel Anti-Demineralization Effect of Orthodontic Adhesive Containing Bioactive Glass and Graphene Oxide: An In-Vitro Study. Materials (Basel) 2018; 11:ma11091728. [PMID: 30223468 PMCID: PMC6163975 DOI: 10.3390/ma11091728] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/12/2018] [Accepted: 09/12/2018] [Indexed: 02/06/2023]
Abstract
White spot lesions (WSLs), a side effect of orthodontic treatment, can result in reversible and unaesthetic results. Graphene oxide (GO) with a bioactive glass (BAG) mixture (BAG@GO) was added to Low-Viscosity Transbond XT (LV) in a ratio of 1, 3, and 5%. The composite’s characterization and its physical and biological properties were verified with scanning electron microscopy (SEM) and X-ray diffraction (XRD); its microhardness, shear bond strength (SBS), cell viability, and adhesive remnant index (ARI) were also assessed. Efficiency in reducing WSL was evaluated using antibacterial activity of S. mutans. Anti-demineralization was analyzed using a cycle of the acid-base solution. Adhesives with 3 wt.% or 5 wt.% of BAG@GO showed significant increase in microhardness compared with LV. The sample and LV groups showed no significant differences in SBS or ARI. The cell viability test confirmed that none of the sample groups showed higher toxicity compared to the LV group. Antibacterial activity was higher in the 48-h group than in the 24 h group; the 48 h test showed that BAG@GO had a high antibacterial effect, which was more pronounced in 5 wt.% of BAG@GO. Anti-demineralization effect was higher in the BAG@GO-group than in the LV-group; the higher the BAG@GO concentration, the higher the anti-demineralization effect.
Collapse
Affiliation(s)
- Seung-Min Lee
- Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan 50612, Korea.
| | - Kyung-Hyeon Yoo
- School of Materials Science and Engineering, Pusan National University, Busan 46241, Korea.
| | - Seog-Young Yoon
- School of Materials Science and Engineering, Pusan National University, Busan 46241, Korea.
| | - In-Ryoung Kim
- Department of Oral Anatomy, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Bong-Soo Park
- Department of Oral Anatomy, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Woo-Sung Son
- Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan 50612, Korea.
| | - Ching-Chang Ko
- Department of Orthodontics, School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27516, USA.
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Yong-Il Kim
- Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan 50612, Korea.
- Institute of Translational Dental Sciences, Pusan National University, Busan 46241, Korea.
| |
Collapse
|
18
|
Choi AN, Lee JH, Son SA, Jung KH, Kwon YH, Park JK. Effect of Dentin Wetness on the Bond Strength of Universal Adhesives. Materials (Basel) 2017; 10:ma10111224. [PMID: 29068404 PMCID: PMC5706171 DOI: 10.3390/ma10111224] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 10/20/2017] [Accepted: 10/23/2017] [Indexed: 12/20/2022]
Abstract
The effects of dentin wetness on the bond strength and adhesive interface morphology of universal adhesives have been investigated using micro-tensile bond strength (μTBS) testing and confocal laser scanning microscopy (CLSM). Seventy-two human third molars were wet ground to expose flat dentin surfaces. They were divided into three groups according to the air-drying time of the dentin surfaces: 0 (without air drying), 5, and 10 s. The dentin surfaces were then treated with three universal adhesives: G-Premio Bond, Single Bond Universal, and All-Bond Universal in self-etch or etch-and-rinse mode. After composite build up, a μTBS test was performed. One additional tooth was prepared for each group by staining the adhesives with 0.01 wt % of Rhodamine B fluorescent dye for CLSM analysis. The data were analyzed statistically using ANOVA and Tukey's post hoc tests (α = 0.05). Two-way ANOVA showed significant differences among the adhesive systems and dentin moisture conditions. An interaction effect was also observed (p < 0.05). One-way ANOVA showed that All-Bond Universal was the only material influenced by the wetness of the dentin surfaces. Wetness of the dentin surface is a factor influencing the micro-tensile bond strength of universal adhesives.
Collapse
Affiliation(s)
- An-Na Choi
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan 50612, Korea.
| | - Ji-Hye Lee
- Department of Oral Pathology & BK21 PLUS Project, School of Dentistry, Institute of Translational Dental Sciences, Pusan National University, Yangsan 50612, Korea.
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan 50612, Korea.
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan 50612, Korea.
| | - Yong Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan 50612, Korea.
| |
Collapse
|
19
|
Jung KH, Seon EM, Choi AN, Kwon YH, Son SA, Park JK. Time of Application of Sodium Ascorbate on Bonding to Bleached Dentin. Scanning 2017; 2017:6074253. [PMID: 29109820 PMCID: PMC5662077 DOI: 10.1155/2017/6074253] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Accepted: 07/12/2017] [Indexed: 06/02/2023]
Abstract
This study examined the effects of different application times of sodium ascorbate (SA) on the bond strength of composite resin to bleached dentin. Specimens with an exposed dentin surface were divided into 3 groups according to the type of bleaching agent used: Group A, mixture of sodium perborate (SP) and distilled water (DW); Group B, mixture of SP and hydrogen peroxide (HP); control group, no bleaching. Each group was classified into 10 subgroups. Subgroups IB and DB underwent immediate bonding and delayed bonding, respectively. 10% SA was applied to 3, 5, 10, and 30 minutes and 1, 24, 48, and 72 hours, respectively. Microtensile bond strength (μTBS) was measured after restoration, and the data was analyzed by one-way ANOVA and Scheffé's test. Before restoration, the dentin surfaces were examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). SEM showed that most dentin surfaces were filled with crystals when SA was applied to more than 24 hours. EDS revealed peaks of calcium, carbon, oxygen, and sodium. The application of SA for 5 minutes to 48 hours or for 30 minutes to 24 hours is suggested when a mixture of SP and DW or HP is used, respectively.
Collapse
Affiliation(s)
- Kyoung-Hwa Jung
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Eun-Mi Seon
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - An-Na Choi
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| |
Collapse
|
20
|
Lee SM, Oh S, Yu SJ, Lee KM, Son SA, Kwon YH, Kim YI. Association between brain lateralization and mixing ability of chewing side. J Dent Sci 2017; 12:133-138. [PMID: 30895038 PMCID: PMC6395226 DOI: 10.1016/j.jds.2016.09.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Revised: 09/18/2016] [Indexed: 11/30/2022] Open
Abstract
Background/purpose Previous studies have suggested that functional dominance in one part of the body can be correlated with functional dominance in another part. Thus, the present research aimed to determine whether brain laterality (handedness, footedness, earedness, and eyedness) was related to mixing ability and chewing side preference. Materials and methods Fifty-four volunteers who were not undergoing any form of dental treatment took part in this study. Self-defined brain laterality was determined through a questionnaire. The volunteers performed five tasks related to brain laterality, which was identified by the side used to perform three or more of the five tasks. Chewing side preference was determined by observing the main gum location on the occlusal area when volunteers chewed for 30 strokes. Mixing Ability Index (MAI) was measured by analyzing the degree of mixing of two differently colored waxes (height, 3 mm; diameter, 20 mm). Occlusion contact area was measured by taking the maximum intercuspation bite with polysiloxane. Results Thirty-nine volunteers (72%) showed significant agreement between brain dominance and chewing preference side. The association between brain dominance and MAI was not significant. The occlusal contact area of the dominant side (mean = 48.2 mm2) was significantly wider than that of the nondominant side (25.7 mm2). Conclusion Brain laterality can be explained by the side of functional (preference of the hands, eyes, ears, and feet, and survey) has a positive correlation with chewing preference side. MAI between the brain dominant and nondominant sides was not significant. This shows that mastication efficiency does not differ between dominant and nondominant sides. So, this study suggests that brain dominance is correlated with chewing preference, but it does not affect efficiency of mastication.
Collapse
Affiliation(s)
- Seung-Min Lee
- Dental Research Institute, Pusan National University Dental Hospital, Yangsan, South Korea
| | - Sewoong Oh
- Dental Research Institute, Pusan National University Dental Hospital, Yangsan, South Korea
| | - Sung Jin Yu
- Dental Research Institute, Pusan National University Dental Hospital, Yangsan, South Korea
| | - Kyung-Min Lee
- Department of Orthodontics, School of Dentistry, Chonnan National University, Gwangju, South Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, Pusan National University Dental Hospital, Yangsan, South Korea
| | - Young Hoon Kwon
- Department of Dental Materials, Pusan National University, Yangsan, South Korea
| | - Yong-Il Kim
- Dental Research Institute, Pusan National University Dental Hospital, Yangsan, South Korea.,Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea.,Institute of Translational Dental Sciences, Pusan National University, Yangsan, South Korea
| |
Collapse
|
21
|
Lee JH, Yi SK, Kim SY, Kim JS, Son SA, Jeong SH, Kim JB. Salivary bisphenol A levels and their association with composite resin restoration. Chemosphere 2017; 172:46-51. [PMID: 28063316 DOI: 10.1016/j.chemosphere.2016.12.123] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 11/24/2016] [Accepted: 12/24/2016] [Indexed: 06/06/2023]
Abstract
Composite resin has been increasingly used in an effort to remove minimal amount of tooth structure and are used for restoring not just carious cavities but also cervical abrasion. To synthesize composite resin, bisphenol A (BPA) is used. The aim of the study was to measure the changes in salivary BPA level related with composite resin restoration. ELISA was used to examine the BPA levels in the saliva collected from 30 volunteers whose teeth were filled with composite resin. Salivary samples were collected immediately before filling and 5 min and 7 d after filling. Wilcoxon signed-ranks test and linear regression were performed to test the significant differences of the changes in BPA levels in saliva. Before a new composite resin filling, there was no significant difference between with and without existing filling of composite resin and BPA level in the saliva was not correlated to the number of filled surfaces with composite resin. However, BPA level in the saliva increased to average 3.64 μg/L from average 0.15 μg/L after filling 5 min. BPA level increased in proportion with the number of filled surfaces. BPA level decreased to average 0.59 after filling 7 d. However it was higher than the BPA level before a new composite resin filling. Considering 50 μg/kg/day as the Tolerable Daily Intake of BPA suggested by European Food Safety Authority, the amount of BPA eluted in saliva after the composite resin filling is considered a safe level that is not a hazard to health at all.
Collapse
Affiliation(s)
- Jung-Ha Lee
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea.
| | - Seung-Kyoo Yi
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea.
| | - Se-Yeon Kim
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea; BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| | - Ji-Soo Kim
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea; BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Republic of Korea.
| | - Seung-Hwa Jeong
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea; BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| | - Jin-Bom Kim
- Department of Preventive and Community Dentistry, School of Dentistry, Pusan National University, Republic of Korea; BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| |
Collapse
|
22
|
Kim Y, Kim S, Jeong T, Son SA, Kim J. Effects of Additional Acid Etching on the Dentin Bond Strengths of One-Step Self-Etch Adhesives Applied to Primary Teeth. J ESTHET RESTOR DENT 2016; 29:110-117. [DOI: 10.1111/jerd.12273] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Affiliation(s)
- Yuhyun Kim
- Department of Pediatric Dentistry and Institute of Transitional Dental Sciences, School of Dentistry; Pusan National University & Dental Research Institute of Pusan National University Dental Hospital; Yangsan Republic of Korea
| | - Shin Kim
- Department of Pediatric Dentistry and Institute of Transitional Dental Sciences, School of Dentistry; Pusan National University & Dental Research Institute of Pusan National University Dental Hospital; Yangsan Republic of Korea
| | - Taesung Jeong
- Department of Pediatric Dentistry and Institute of Transitional Dental Sciences, School of Dentistry; Pusan National University & Dental Research Institute of Pusan National University Dental Hospital; Yangsan Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry and Institute of Transitional Dental Sciences, School of Dentistry; Pusan National University & Dental Research Institute of Pusan National University Dental Hospital; Yangsan Republic of Korea
| | - Jiyeon Kim
- Department of Pediatric Dentistry and Institute of Transitional Dental Sciences, School of Dentistry; Pusan National University & Dental Research Institute of Pusan National University Dental Hospital; Yangsan Republic of Korea
| |
Collapse
|
23
|
Son SA, Park JK, Seo DG, Ko CC, Kwon YH. How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites? Clin Oral Investig 2016; 21:559-565. [PMID: 27475636 DOI: 10.1007/s00784-016-1920-2] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Accepted: 07/20/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The purpose of this study was to investigate the microhardness, polymerization shrinkage, and translucency of bulk-fill composites (BFCs) which have different light attenuation properties and filler contents. MATERIALS AND METHODS Five BFCs [Filtek Bulk Fill (FB), SureFil SDR (SS), Venus Bulk Fill (VB), SonicFill (SF), and Tetric N-Ceram Bulk Fill (TB)] and two resin-based composites (RBCs) [Tetric N-Ceram (TN) and Filtek Z350XT Flowable (ZF)] were chosen. Numbers of transmitted photons, refractive index, microhardness at different thicknesses, polymerization shrinkage, and translucency parameter (TP) were evaluated. RESULTS Attenuation coefficients (ACs) based on measured photons ranged from -0.88 to -1.90. BFCs, except SF, had lower AC values than TN or ZF, and BFCs, except TN, had smaller refractive index decreases between top and bottom surfaces. Regardless of an exponential decrease in photon counts, microhardness decreased linearly as specimen thickens. Moreover, microhardness of BFCs showed smaller top-to-bottom decreases (11.5-48.8 %) than TN or ZF (57.3 and 71.5 %, respectively). BFCs with low filler contents showed lower microhardness and higher polymerization shrinkage than those of high filler contents. Also, BFCs had significantly higher (p < 0.001) TP values than TN or ZF. CONCLUSION BFCs attenuated light less than RBCs. However, some BFCs had much lower top surface microhardness and higher polymerization shrinkage than tested RBCs. CLINICAL RELEVANCE Despite the convenience of bulk filling, careful selection of BFC is advised because some BFCs have worse microhardness and polymerization shrinkage than RBCs due to their lower filler contents.
Collapse
Affiliation(s)
- Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, 50612, South Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, 50612, South Korea
| | - Deog-Gyu Seo
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Seoul, 02707, South Korea
| | - Ching-Chang Ko
- Department of Orthodontics, School of Dentistry, University of North Carolina, Chapel Hill, NC, 27599, USA
| | - Yong Hoon Kwon
- Department of Dental Materials, School of Dentistry, Dental Research Institute, Pusan National University Dental Hospital, Pusan National University, Yangsan, 50612, South Korea.
| |
Collapse
|
24
|
Son SA, Jung KH, Ko CC, Kwon YH. Spectral characteristics of caries-related autofluorescence spectra and their use for diagnosis of caries stage. J Biomed Opt 2016; 21:15001. [PMID: 26747473 DOI: 10.1117/1.jbo.21.1.015001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Accepted: 12/04/2015] [Indexed: 06/05/2023]
Affiliation(s)
- Sung-Ae Son
- Pusan National University, School of Dentistry, Department of Conservative Dentistry, Yangsan 50612, Republic of Korea
| | - Kyeong-Hoon Jung
- Kookmin University, Department of Electrical Engineering, Seoul 02707, Republic of Korea
| | - Ching-Chang Ko
- University of North Carolina, School of Dentistry, Department of Orthodontics, Chapel Hill, North Carolina 27599, United States
| | - Yong Hoon Kwon
- Pusan National University, School of Dentistry, Department of Dental Materials, Yangsan 50612, Republic of Korea
| |
Collapse
|
25
|
Kim RJY, Son SA, Hwang JY, Lee IB, Seo DG. Comparison of photopolymerization temperature increases in internal and external positions of composite and tooth cavities in real time: Incremental fillings of microhybrid composite vs. bulk filling of bulk fill composite. J Dent 2015; 43:1093-1098. [DOI: 10.1016/j.jdent.2015.07.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 06/24/2015] [Accepted: 07/01/2015] [Indexed: 10/23/2022] Open
|
26
|
Moon JD, Seon EM, Son SA, Jung KH, Kwon YH, Park JK. Effect of immersion into solutions at various pH on the color stability of composite resins with different shades. Restor Dent Endod 2015; 40:270-6. [PMID: 26587412 PMCID: PMC4650522 DOI: 10.5395/rde.2015.40.4.270] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Accepted: 07/02/2015] [Indexed: 11/17/2022] Open
Abstract
Objectives This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE L*a*b* color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (ΔE*) and the translucency parameter (TP) were calculated using the color coordinates. Results ΔE* ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ΔE* values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ΔE* change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.
Collapse
Affiliation(s)
- Ji-Deok Moon
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Eun-Mi Seon
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| |
Collapse
|
27
|
Youm SH, Jung KH, Son SA, Kwon YH, Park JK. Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements. J Adv Prosthodont 2015; 7:317-22. [PMID: 26330979 PMCID: PMC4551788 DOI: 10.4047/jap.2015.7.4.317] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 03/20/2015] [Accepted: 04/13/2015] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The aim was to evaluate the effect of curing mode and different dentin surface pretreatment on microtensile bond strength (µTBS) of self-adhesive resin cements. MATERIALS AND METHODS Thirty-six extracted human permanent molars were sectioned horizontally exposing flat dentin surface. The teeth were divided into 12 groups (3 teeth/group) according to the dentin surface pretreatment methods (control, 18% EDTA, 10% Polyacrylic acid) and curing mode (self-curing vs. light-curing) of cement. After pretreatment, composite resin blocks were cemented with the following: (a) G-CEM LinkAce; (b) RelyX U200, followed by either self-curing or light-curing. After storage, the teeth were sectioned and µTBS test was performed using a microtensile testing machine. The data was statistically analyzed using one-way ANOVA, Student T-test and Scheffe's post-hoc test at P<.05 level. RESULTS For G-CEM LinkAce cement groups, polyacrylic acid pretreatment showed the highest µTBS in the self-cured group. In the light-cured group, no significant improvements were observed according to the dentin surface pretreatment. There were no significant differences between curing modes. Both dentin surface pretreatment methods helped to increase the µTBS of RelyX U200 resin cement significantly and degree of pretreatment effect was similar. No significant differences were found regarding curing modes except control groups. In the comparisons of two self-adhesive resin cements, all groups within the same pretreatment and curing mode were significantly different excluding self-cured control groups. CONCLUSION Selecting RelyX U200 used in this study and application of dentin surface pretreatment with EDTA and polyacrylic acid might be recommended to enhance the bond strength of cement to dentin.
Collapse
Affiliation(s)
- Seung-Hyun Youm
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Reserch Institute, Yangsan, Republic of Korea
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Reserch Institute, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Reserch Institute, Yangsan, Republic of Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Reserch Institute, Yangsan, Republic of Korea
| |
Collapse
|
28
|
Ro JH, Son SA, Park JK, Jeon GR, Ko CC, Kwon YH. Effect of two lasers on the polymerization of composite resins: single vs combination. Lasers Med Sci 2015; 30:1497-503. [PMID: 25895056 DOI: 10.1007/s10103-015-1753-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Accepted: 04/02/2015] [Indexed: 01/14/2023]
Abstract
The selection of a light-curing unit for the curing composite resins is important to achieve best outcomes. The purpose of the present study was to test lasers of 457 and 473 nm alone or in combination under different light conditions with respect to the cure of composite resins. Four different composite resins were light cured using five different laser combinations (530 mW/cm(2) 457 nm only, 530 mW/cm(2) 473 nm only, 177 mW/cm(2) 457 + 177 mW/cm(2) 473 nm, 265 mW/cm(2) 457 + 265 mW/cm(2) 473 nm, and 354 mW/cm(2) 457 + 354 mW/cm(2) 473 nm). Microhardness and polymerization shrinkage were evaluated. A light-emitting diode (LED) unit was used for comparison purposes. On top surfaces, after aging for 24 h, microhardness achieved using the LED unit and the lasers with different conditions ranged 42.4-65.5 and 38.9-67.7 Hv, respectively, and on bottom surfaces, corresponding ranges were 25.2-56.1 and 18.5-55.7 Hv, respectively. Of the conditions used, 354 mW/cm(2) 457 nm + 354 mW/cm(2) 473 nm produced the highest bottom microhardness (33.8-55.6 Hv). On top and bottom surfaces, microhardness by the lowest total light intensity, 354 (177 × 2) mW/cm(2), ranged 39.0-60.5 and 18.5-52.8 Hv, respectively. Generally, 530 mW/cm(2) at 457 nm produced the lowest polymerization shrinkage. However, shrinkage values obtained using all five laser conditions were similar. The study shows the lasers of 457 and 473 nm are useful for curing composite resins alone or in combination at much lower light intensities than the LED unit.
Collapse
Affiliation(s)
- Jung-Hoon Ro
- Department of Biomedical Engineering, School of Medicine, Yangsan, 626-770, Korea
| | | | | | | | | | | |
Collapse
|
29
|
Kim EH, Jung KH, Son SA, Hur B, Kwon YH, Park JK. Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites. Restor Dent Endod 2015; 40:128-35. [PMID: 25984474 PMCID: PMC4432255 DOI: 10.5395/rde.2015.40.2.128] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2014] [Accepted: 12/02/2014] [Indexed: 11/11/2022] Open
Abstract
OBJECTIVES This study evaluated the effects of the resin thickness on the microhardness and optical properties of bulk-fill resin composites. METHODS Four bulk-fill (Venus Bulk Fill, Heraeus Kulzer; SDR, Dentsply Caulk; Tetric N-Ceram Bulk Fill, Ivoclar vivadent; SonicFill, Kerr) and two regular resin composites (Charisma flow, Heraeus Kulzer; Tetric N-Ceram, Ivoclar vivadent) were used. Sixty acrylic cylindrical molds were prepared for each thickness (2, 3 and 4 mm). The molds were divided into six groups for resin composites. The microhardness was measured on the top and bottom surfaces, and the colors were measured using Commission Internationale d'Eclairage (CIE) L (*) a (*) b (*) system. Color differences according to the thickness and translucency parameters and the correlations between the microhardness and translucency parameter were analyzed. The microhardness and color differences were analyzed by ANOVA and Scheffe's post hoc test, and a student t-test, respectively. The level of significance was set to α = 0.05. RESULTS The microhardness decreased with increasing resin thickness. The bulk-fill resin composites showed a bottom/top hardness ratio of almost 80% or more in 4 mm thick specimens. The highest translucency parameter was observed in Venus Bulk Fill. All resin composites used in this study except for Venus Bulk Fill showed linear correlations between the microhardness and translucency parameter according to the thickness. CONCLUSIONS Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk.
Collapse
Affiliation(s)
- Eun-Ha Kim
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Bock Hur
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| |
Collapse
|
30
|
Son SA. Simple methods to enhance bond strength of self-adhesive resin cements. Restor Dent Endod 2015; 40:332-3. [PMID: 26587421 PMCID: PMC4650531 DOI: 10.5395/rde.2015.40.4.332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
31
|
Son SA, Park JK, Jung KH, Ko CC, Jeong CM, Kwon YH. Effect of 457 nm diode-pumped solid state laser on the polymerization composite resins: microhardness, cross-link density, and polymerization shrinkage. Photomed Laser Surg 2014; 33:3-8. [PMID: 25549163 DOI: 10.1089/pho.2014.3786] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE The purpose of the present study was to test the usefulness of 457 nm diode-pumped solid state (DPSS) laser as a light source to cure composite resins. MATERIALS AND METHODS Five different composite resins were light cured using three different light-curing units (LCUs): a DPSS 457 nm laser (LAS), a light-emitting diode (LED), and quartz-tungsten-halogen (QTH) units. The light intensity of LAS was 560 mW/cm(2), whereas LED and QTH LCUs was ∼900 mW/cm(2). The degree of polymerization was tested by evaluating microhardness, cross-link density, and polymerization shrinkage. RESULTS Before water immersion, the microhardness of laser-treated specimens ranged from 40.8 to 84.7 HV and from 31.7 to 79.0 HV on the top and bottom surfaces, respectively, and these values were 3.3-23.2% and 2.9-31.1% lower than the highest microhardness obtained using LED or QTH LCUs. Also, laser-treated specimens had lower top and bottom microhardnesses than the other LCUs treated specimens by 2.4-19.4% and 1.4-27.8%, respectively. After ethanol immersion for 24 h, the microhardness of laser-treated specimens ranged from 20.3 to 63.2 HV on top and bottom surfaces, but from 24.9 to 71.5 HV when specimens were cured using the other LCUs. Polymerization shrinkage was 9.8-14.7 μm for laser-treated specimens, and these were significantly similar or lower (10.2-16.0 μm) than those obtained using the other LCUs. CONCLUSIONS The results may suggest that the 457 nm DPSS laser can be used as a light source for light-curing dental resin composites.
Collapse
Affiliation(s)
- Sung-Ae Son
- 1 Department of Conservative Dentistry, School of Dentistry, Pusan National University , Yangsan, Korea
| | | | | | | | | | | |
Collapse
|
32
|
Ahn J, Jung KH, Son SA, Hur B, Kwon YH, Park JK. Effect of additional etching and ethanol-wet bonding on the dentin bond strength of one-step self-etch adhesives. Restor Dent Endod 2014; 40:68-74. [PMID: 25671215 PMCID: PMC4320279 DOI: 10.5395/rde.2015.40.1.68] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2014] [Accepted: 10/11/2014] [Indexed: 11/29/2022] Open
Abstract
Objectives This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. Materials and Methods Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncan's post hoc test. Results In GB, XV and SE (pH ≤ 2), the bond strength was decreased significantly when the dentin was etched (p < 0.05). In BB, AE and SU (pH 2.4 - 2.7), additional etching did not affect the bond strength (p > 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. Conclusions The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin.
Collapse
Affiliation(s)
- Joonghee Ahn
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Kyoung-Hwa Jung
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Bock Hur
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| |
Collapse
|
33
|
Son SA, Roh HM, Hur B, Kwon YH, Park JK. The effect of resin thickness on polymerization characteristics of silorane-based composite resin. Restor Dent Endod 2014; 39:310-8. [PMID: 25383351 PMCID: PMC4223102 DOI: 10.5395/rde.2014.39.4.310] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Accepted: 07/23/2014] [Indexed: 11/16/2022] Open
Abstract
Objectives This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. Results The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.
Collapse
Affiliation(s)
- Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Hyoung-Mee Roh
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Bock Hur
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| |
Collapse
|
34
|
Abstract
The purpose of this study were to evaluate the discoloration of a silorane-based resin and two methacrylated-based resin composites upon exposure to different staining solutions coffee, red wine, porcine liver esterase and distilled water for 7 days. The colors of all specimens before and after storage in the solutions were measured by a spectrophotometer based on CIE Lab system, and the color differences thereby calculated. Data were statistically analyzed by ANOVA and Scheffe's test. For coffee and red wine, the mean color change in silorane-based resin was significantly lower than that in methacylate-based resin composites (p<0.05). For porcine liver esterase and distilled water, there was no significant difference in the mean values of color change between silorane- and methacrylate-based resin composites (p>0.05). In conclusion, the silorane-based resin composites exhibited better color stability (less ΔE) after exposure to the colored staining solutions.
Collapse
Affiliation(s)
- Aromi Kang
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Korea
| | | | | | | | | | | |
Collapse
|
35
|
Lee IS, Son SA, Hur B, Kwon YH, Park JK. The effect of additional etching and curing mechanism of composite resin on the dentin bond strength. J Adv Prosthodont 2013; 5:479-84. [PMID: 24353889 PMCID: PMC3865206 DOI: 10.4047/jap.2013.5.4.479] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 11/07/2013] [Accepted: 11/18/2013] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ×20 magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (α=.05). RESULTS Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.
Collapse
Affiliation(s)
- In-Su Lee
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Bock Hur
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea
| |
Collapse
|
36
|
Yun DI, Ku RM, Son SA, Park JK, Ko CC, Kim HI, Kwon YH. Influence of a blue DPSS laser on specimen thickness of composite resins. Photomed Laser Surg 2012; 30:536-42. [PMID: 22793383 DOI: 10.1089/pho.2012.3231] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE The purpose of the present study was to investigate the effect of 473 nm diode-pumped solid state (DPSS) laser on the curing depth of composite resins. BACKGROUND DATA Within the turbid media, light attenuates significantly because of the absorption and scattering. MATERIALS AND METHODS For the study, three different composite resins and light-curing units (LCUs) (a quartz-tungsten-halogen [QTH], light-emitting-diode [LED], and DPSS laser) were used. The number of photons transmitted through the specimens, degree of conversion (DC), microhardness, and refractive index of the specimens on different thicknesses were evaluated. RESULTS The incident light exponentially decreased within the specimens. Among the LCUs, QTH showed the least photon loss. The DC obtained using the DPSS laser and QTH was significantly greater (p<0.001) than that obtained using LED. The specimens light cured using the DPSS laser showed slightly lower microhardness than that cured by the other LCUs. On each depth, the mean refractive index was not significantly different for the LCUs used. DC, microhardness, and refractive index had inverse linear correlation with specimen thickness despite exponential decrease of photons number. On the other hand, DC, microhardness, and refractive index were linearly correlated to each other regardless of LCUs. CONCLUSIONS The DPSS laser of 473 nm achieved a similar level of polymerization within the specimens as those of the other LCUs even with much lower light intensity. This laser can be applied as a light source for light curing of composite resins.
Collapse
Affiliation(s)
- Dong-In Yun
- Department of Dental Materials, School of Dentistry and Medical Research Institute, Pusan National University, Yangsan, Korea
| | | | | | | | | | | | | |
Collapse
|
37
|
Baek DM, Park JK, Son SA, Ko CC, Garcia-Godoy F, Kim HI, Kwon YH. Mechanical properties of composite resins light-cured using a blue DPSS laser. Lasers Med Sci 2012; 28:597-604. [PMID: 22585380 DOI: 10.1007/s10103-012-1117-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2012] [Accepted: 05/01/2012] [Indexed: 12/31/2022]
Abstract
Lasers have many favorable features as a light source owing to their monochromaticity and coherence. This study examined the mechanical properties of composite resins that were light-cured using a diode-pumped solid state (DPSS) laser. Eight composite resins were light-cured using four different light sources (one quartz-tungsten-halogen (QTH), two light-emitting diodes (LEDs), and one DPSS laser with a wavelength of 473 nm). The light intensity of the DPSS laser and remaining light-curing units were approximately 500 and 900 mW/cm(2), respectively. The microhardness, flexural properties, and compressive properties were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. In most cases, the microhardness, flexural properties, and compressive properties of the specimens light-cured using the DPSS laser were similar to those obtained using the other light-curing units. Within the limits of the study, the microhardness, flexural modulus, and compressive strength were linearly correlated with the filler content (in weight percent). The flexural modulus and compressive modulus were also linearly correlated with the microhardness. Even with a much lower light intensity, the DPSS laser with a wavelength of 473 nm can polymerize composite resins and give comparable mechanical properties to those obtained using the other light-curing units.
Collapse
Affiliation(s)
- Du-Man Baek
- Department of Dental Materials, School of Dentistry, Pusan National University, Yangsan, 626-870, South Korea
| | | | | | | | | | | | | |
Collapse
|
38
|
Park HJ, Son SA, Hur B, Kim HC, Kwon YH, Park JK. Effect of the difference in spectral outputs of the single and dual-peak LEDs on the microhardness and the color stability of resin composites. ACTA ACUST UNITED AC 2011. [DOI: 10.5395/jkacd.2011.36.2.108] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Hye-Jung Park
- Department of Conservative Dentistry, Pusan National University School of Dentistry, Yangsan, Korea
| | - Sung-Ae Son
- Department of Conservative Dentistry, Pusan National University School of Dentistry, Yangsan, Korea
| | - Bock Hur
- Department of Conservative Dentistry, Pusan National University School of Dentistry, Yangsan, Korea
| | - Hyeon-Cheol Kim
- Department of Conservative Dentistry, Pusan National University School of Dentistry, Yangsan, Korea
| | - Yong-Hoon Kwon
- Department of Dental Materials, Pusan National University School of Dentistry and Medical Research Institute, Yangsan, Korea
| | - Jeong-Kil Park
- Department of Conservative Dentistry, Pusan National University School of Dentistry, Yangsan, Korea
| |
Collapse
|