1
|
Leles CR, Curado TFF, Nascimento LN, Silva JR, de Paula MS, McKenna G, Schimmel M. Changes in masticatory performance and bite force after treatment with mandibular overdentures retained by four titanium-zirconium mini implants: One-year randomised clinical trial. J Oral Rehabil 2024. [PMID: 38685704 DOI: 10.1111/joor.13722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/12/2024] [Accepted: 04/19/2024] [Indexed: 05/02/2024]
Abstract
OBJECTIVE This prospective study is part of a randomised clinical trial and reports the changes in masticatory performance (MP) and bite force, and explores their influential factors, 1 year after the provision of mandibular overdentures retained by four titanium-zirconium mini implants. METHODS Edentulous patients received conventional complete dentures, followed by placement of four mini implants (Straumann® Mini Implant System) in the anterior mandible and converting the conventional prosthesis into a mandibular overdenture. Treatment protocols were randomised using a 2×2 factorial design combining different surgical (flapped vs. flapless) and loading (immediate vs. delayed) protocols. MP was assessed using a two-colour mixing ability test and a colorimetric analysis to measure the level of colour mixing (Variance of Hue-VoH). Maximum voluntary bite force (MBF) was measured by a digital gnathodynamometer in the posterior and anterior regions. Sex, age, surgical and loading protocols and ridge morphology were tested as independent variables. MP and MBF tests were performed at baseline (pre-treatment) and the 3-, 6- and 12-month after implant loading. Descriptive statistics, independent t-test, and linear mixed-effect model (LMM) regression were used for data analysis. RESULTS Seventy-four participants were assessed and 73 completed the 1-year follow-up. Statistically significant improvements in functional parameters were observed in all follow-up periods compared to baseline (p < .001). The flapless protocol was associated with higher improvement in MP at the 3-month follow-up (p = .004), while less resorbed ridges were associated with better MP (p = .038) and higher MBF (p < .001). CONCLUSION The mandibular overdenture protocol using four titanium-zirconium mini implants was effective in improving MP and MBF of edentulous patients, compared to pre-treatment values. The findings also suggest that improvements in chewing function and bite force are impacted by clinical factors since better outcomes were observed for flapless surgeries and less resorbed edentulous ridges. CLINICAL TRIAL REGISTRATION ClinicalTrials.Gov ID NCT04760457.
Collapse
Affiliation(s)
- Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Division of Gerodontology, Department of Reconstructive Dentistry, School of Dental Medicine of the University of Bern, Bern, Switzerland
| | | | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Division of Gerodontology, Department of Reconstructive Dentistry, School of Dental Medicine of the University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
2
|
Maniewicz S, Curado TFF, McKenna G, Leles CR, Müller F. Single lateral implant for mandibular overdentures as a fallback solution or a viable treatment alternative: Four case reports. J Prosthodont 2024. [PMID: 38512962 DOI: 10.1111/jopr.13841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 03/01/2024] [Indexed: 03/23/2024] Open
Abstract
This report of four clinical cases aims to illustrate the use of a lateral implant as a solution for implant overdentures in the mandible in different clinical situations. The first two cases describe the clinical situations of patients wearing two-implant mandibular overdentures until the failure of one of the implants, one due to implant loss and the other due to a fracture of an abutment screw, and how the conditions were managed. The third case illustrates the placement of a single implant to retain an overdenture, where a midline implant, as originally planned, was not feasible due to anatomic reasons. The final case describes the use of a lateral implant to support and retain a single-implant mandibular overdenture. The four cases demonstrate that a single lateral implant can be utilized as sole retention in cases of a failing contra-lateral implant and as an alternative to a single implant in the midline.
Collapse
Affiliation(s)
- Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Cláudio Rodrigues Leles
- Department of Oral Rehabilitation, School of Dentistry, Federal University of Goias, Goiania, Goias, Brazil
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Division of Geriatrics, Department of Rehabilitation and Geriatrics, University Hospitals of Geneva, Thônex, Switzerland
| |
Collapse
|
3
|
Curado TFF, Silva JR, Nascimento LN, Leles JLR, McKenna G, Schimmel M, Leles CR. Implant survival/success and peri-implant outcomes of titanium-zirconium mini implants for mandibular overdentures: Results from a 1-year randomized clinical trial. Clin Oral Implants Res 2023; 34:769-782. [PMID: 37254798 DOI: 10.1111/clr.14102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/15/2023] [Accepted: 05/18/2023] [Indexed: 06/01/2023]
Abstract
OBJECTIVE To report the 1-year implant survival/success and peri-implant outcomes of mandibular overdentures retained by four titanium-zirconium mini implants (Straumann® Mini Implant System), and to assess how surgery and loading protocols influence these outcomes. MATERIALS AND METHODS A 2 × 2 factorial randomized clinical trial (RCT) tested the combined effects of two loading protocols (immediate or delayed) and two surgical approaches (flapless or flapped) on the success/survival of the mini implants, and peri-implant parameters (plaque, bleeding, sulcus depth, gingival position, and marginal bone loss). Outcomes were assessed up to 1-year after loading, and generalized estimating equations (GEEs) were used to analyze longitudinal and within-patient clustered data. RESULTS Two hundred and ninety-six implants were placed in 74 patients. The implant survival/success rates after 1 year were 100%, and no major biological complications were observed. After 1-year, descriptive data suggest no noticeable changes in plaque scores, whilst a reduction in bleeding scores at the 6-month and 1-year follow-ups compared to baseline. Good longitudinal stability was observed for the probing depth and gingival margin height measures. Overall mean marginal bone loss was 0.68 (±0.68) mm after 3 months and 0.89 (±0.75) mm after 1-year. The flapless protocol showed better results on soft tissue stability and health but a slightly higher risk for marginal bone loss. CONCLUSION The results of this RCT suggest that mandibular overdentures retained by this novel mini implant system represent a safe and predictable treatment option as confirmed by implant survival/success and peri-implant outcomes, even when flapless surgery and immediate loading protocols are adopted.
Collapse
Affiliation(s)
| | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
| |
Collapse
|
4
|
Leles CR, Nascimento LN, Silva JR, de Paula MS, Curado TFF, McKenna G, Schimmel M. Willingness to accept or refuse mandibular implant overdenture treatment: A prospective study on edentulous enrolled in a clinical trial. J Oral Rehabil 2023; 50:392-399. [PMID: 36789570 DOI: 10.1111/joor.13429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/26/2022] [Accepted: 02/06/2023] [Indexed: 02/16/2023]
Abstract
BACKGROUND Several complete denture wearers have major complaints and may be benefitted from implant treatment. However, the factors that shape the demand for and utilization of implants need further investigation. OBJECTIVE The aim was to evaluate edentulous patient's willingness to accept or refuse the offer and provision of implant-retained treatment. METHODS As part of a clinical trial, edentulous subjects were offered a mandibular overdenture retained by four mini-implants opposing a conventional maxillary denture. Treatment was offered without any financial costs for the patients. Patients' level of interest in receiving treatment was assessed using a 5-point Likert scale, and they were asked to respond to a list of reasons that led to their decision to accept or refuse implants. Those who refused implants received conventional prosthodontic interventions as required, and those who accepted implant treatment underwent surgical planning and implant placement. RESULTS Of 175 eligible subjects, 147 accepted the offer of treatment and were invited to take part in the study (69.4% women, mean age 67.4 ± 10.0 years). Overall, 111 patients (75.5%) expressed a positive intention to undergo implant treatment at the initial contact. Implant treatment was performed for 56.3% (9/16) of those who answered 'probably yes' about their level of interest in implant treatment on the Likert scale, and 69.6% (64/92) of 'certainly yes' (p < .001). Older subjects were less likely to receive implants (OR = 0.93; p = .036), whilst those with a positive intention towards implants (OR = 3.15; p = .001), those previously treated by the dental team (OR = 7.89; p < .001), and who actively demanded implants (OR = 18.1; p < .001) were more likely to accept treatment. Improved chewing was the most common reason for accepting implants, whilst fear of surgery was the most reported reason for refusal. CONCLUSION Refusal of implants was high among edentate patients even when financial costs were removed. Patients' initial attitude towards acceptance is a key factor in the demand for and uptake of implant therapy.
Collapse
Affiliation(s)
| | | | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
5
|
Leles CR, Leles JLR, Curado TFF, Silva JR, Nascimento LN, de Paula MS, Maniewicz S, Schimmel M, McKenna G. Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium-zirconium mini-implants for overdentures: A cross-sectional analysis. Clin Implant Dent Relat Res 2023; 25:426-434. [PMID: 36623506 DOI: 10.1111/cid.13181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 12/29/2022] [Accepted: 01/01/2023] [Indexed: 01/11/2023]
Abstract
OBJECTIVE The aim of this study was to assess the final insertion torque values achieved using site-specific drilling protocols for a novel mini implant system for removable complete overdentures. Anatomical and technical factors influencing final insertion torque were recorded and analyzed. MATERIAL AND METHODS Participants were randomized to two surgical protocol groups (flapped or flapless) and all received four mini implants (Straumann® mini implant system; Straumann AG) in the anterior mandible, using a 1.6 mm needle drill and a 2.2 mm pilot drill for the implant bed site preparation. The final insertion torque was recorded as the main outcome variable during surgery. Bone type, radiographical bone density, ridge form, implant length, and the drilling protocol were considered as independent variables. Descriptive statistics, generalized estimating equations (GEE) regression, and heatmap charts were used for data analyses. RESULTS A total of 296 mini implants were placed in 74 patients (mean age = 64.1 ± 8.0; 64.9% female) using flapless (n = 37) or flapped (n = 37) surgeries. Mean final insertion torque was 55.8 ± 18.4 Ncm (10.5% > 35 Ncm, 48.9% between 35 and 65 Ncm, and 40.6% > 65 Ncm). The needle drill was used in only 43.9% of the implant bed sites. Higher final torque values were observed for higher bone densities (bone type I > II > III, and D1-D2 > D3-D4), highly resorbed ridge forms (5-6 > 3-4), flapped surgeries, and male patients. However, regression models showed that the likelihood of achieving optimal insertion torque (≥35 and ≤65 Ncm) was higher for females (OR = 2.14; 95%CI = 1.14-4.01; p = 0.018), ridge forms 3-4 (OR = 2.87; 95%CI = 1.05-7.85; p = 0.040), and flapless surgeries (OR = 1.96; 95%CI = 1.09-3.51; p = 0.024). CONCLUSIONS Sufficient primary stability for immediate loading was achieved for the majority of the mini implants placed. Surgical implant bed preparation should be site-specific to achieve optimal primary stability for immediate loading while avoiding excessive insertion torque.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gerald McKenna
- Consultant in Restorative Dentistry, Centre for Public Health, Queen's University Belfast, Belfast, UK
| |
Collapse
|
6
|
de Araújo SC, Hartmann R, Curado TFF, Schimmel M, Leles CR. A 3‐year prospective cohort on the incidence of prosthodontic complications associated with three implant treatment options for the edentulous mandible. J Oral Rehabil 2022; 49:1155-1162. [DOI: 10.1111/joor.13371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 07/05/2022] [Accepted: 09/06/2022] [Indexed: 12/01/2022]
Affiliation(s)
| | | | | | - Martin Schimmel
- Department of Reconstructive Dentistry, Division of Gerodontology School of Dental Medicine of the University of Bern Switzerland
- Division of Gerodontology and Removable Prosthodontics University Clinics of Dental Medicine, University of Geneva Geneva Switzerland
| | | |
Collapse
|
7
|
Leles CR, de Paula MS, Curado TFF, Silva JR, Leles JLR, McKenna G, Schimmel M. Flapped versus flapless surgery and delayed versus immediate loading for a four mini implant mandibular overdenture: a RCT on post-surgical symptoms and short-term clinical outcomes. Clin Oral Implants Res 2022; 33:953-964. [PMID: 35818640 DOI: 10.1111/clr.13974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 06/14/2022] [Accepted: 06/22/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVE This factorial randomized clinical trial tested the effects of the surgical approach (flapped - FPS versus flapless - FLS surgery) and loading protocol (delayed - DL versus immediate - IL) for treatment with a four mini implant mandibular overdenture. MATERIAL AND METHODS A total of 296 one-piece titanium-zirconium mini implants were inserted in 74 patients (IL/FLS=17; IL/FPS=18; DL/FLS=20; DL/FPS=19). Outcomes included patient's perceived surgical burdens, clinical time, implant survival, and post-surgical symptoms and complications, assessed immediately after surgery, in the 7-day and 6-week follow-ups. RESULTS Perceived surgical burdens were relatively low, higher for females, and no difference was found between flapped and flapless surgery. Surgical time was lower for flapless surgery. Overall symptoms were mild after 24 hours, and higher for females. Less symptoms were recorded for the flapless surgery compared to the flapped for the delayed loading patients, and flapless surgery was associated with lower risk of bleeding. No early implant failure was observed until the 6-week follow-up. Delayed was associated with discontinuous use of the prosthesis and poor function. Lower complaint rates were observed for immediate loading regardless of the surgery protocol. CONCLUSIONS Mini implants for mandibular overdenture is a feasible option regardless of surgical access and loading protocol, with high safety and predictable survival rates, and low incidence of post-insertion complications. Flapless surgery requires less clinical time and result in easier intraoral prosthetic incorporation of attachments compared to flapped surgeries. Immediate loading did not increase the risk of early implant failure when satisfactory primary stability was achieved.
Collapse
Affiliation(s)
| | | | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, United Kingdom
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Switzerland
| |
Collapse
|
8
|
Leles CR, Silva JR, Curado TFF, Schimmel M, McKenna G. The Potential Role of Dental Patient-Reported Outcomes (dPROs) in Evidence-Based Prosthodontics and Clinical Care: A Narrative Review. Patient Relat Outcome Meas 2022; 13:131-143. [PMID: 35685865 PMCID: PMC9172924 DOI: 10.2147/prom.s256724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 05/17/2022] [Indexed: 12/15/2022] Open
Abstract
Oral health problems are associated with poor quality of life, with the potential to cause functional, aesthetic, nutritional, and psychological difficulties, in addition to pain and suffering. Traditionally, dental treatment outcomes are measured using purely clinical parameters; however, this may be ineffective as these parameters cannot adequately capture the full impact of poor oral health on the patient, or their respective coping strategies. From this perspective, there are significant benefits when the patient’s perception of their care is considered, and included in treatment planning and delivery. The impacts perceived by the patient on their treatment outcomes can be measured using patient-reported outcomes (PROS), or more specifically with dPROS, focused on dental patient-reported outcomes. Although there are some instruments available for measuring these outcomes in clinical trials, very little information is available for explaining the context in which these outcomes are considered, and also how to capture this information using appropriate instruments, specially in evidence-based dental practice. This article aims to review the literature, seeking to describe what has been considered about assessing patient’s outcomes, as well as how to measure them, and explore the potential benefits of using dPROS in evidence-based prosthodontics and clinical care of partially and fully edentulous patients.
Collapse
Affiliation(s)
- Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Correspondence: Cláudio Rodrigues Leles, Faculdade de Odontologia, Universidade Federal de Goiás, Praça Universitária, s/n, Setor Universitário, Goiania, Goias, 74605-220, Brazil, Tel +55 62 32096052, Email
| | | | | | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Gerald McKenna
- Centre for Public Health, Queen’s University, School of Medicine Dentistry & Biomedical Sciences, Institute of Clinical Science, Belfast, UK
| |
Collapse
|