1
|
Nrecaj A, Takeshita L, Moreira YM, Schimmel M, Leles CR, Srinivasan M. Reliability between the two-colour chewing gum and the gummy-jelly tests used for the assessment of masticatory performance. J Oral Rehabil 2024; 51:954-961. [PMID: 38379391 DOI: 10.1111/joor.13665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 01/13/2024] [Accepted: 02/05/2024] [Indexed: 02/22/2024]
Abstract
OBJECTIVE This study aimed to evaluate the reliability of two methods used to assess masticatory performance and attempt to correlate them to achieve interchangeability between the methods. METHODS Twelve healthy dentate volunteers (men = 6, women = 6; mean age = 28.3 ± 4.1) with no known dental or medical pathologies were requested to participate in this study. Each participant completed three masticatory performance assessments, including two two-colour mixing-ability tests using chewing-gums (CG: gum#1 and gum#2) and the gummy-jelly (GJ) test. For each method, participants created five samples each (total = 15 measurements per participant, gum#1 = 5, gum#2 = 5, GJ = 5). For the gum#1 and gum#2 methods, the predetermined chewing cycles were fixed at 10, 15, 20, 25 and 30 cycles, and for the GJ method, the time duration was fixed at 10, 15, 20, 25 and 30 s. The parameter measures were submitted to Z-score transformation, and Bland-Altman plots were generated to graphically compare the differences between two techniques against their means. Additionally, mountain plot was used to assess the cumulative distribution of measurement error between the methods. RESULTS A total of 180 measurements were recorded. There were significant correlations between the number of chewing cycles/chewing time and masticatory performance using the gum#1 (r = -.753; p < .001), gum#2 (r = -.838; p < .001) and GJ (r = .730). When all tests were considered together for each method, significant correlations were found (p < .001). A descriptive range of mean values aiming to produce reference value ranges for predictive purposes was achieved considering the interchangeably among the methods [CG = GJ (VoH-mg = dL): 10 cycle = 10 s: 0.329 = 110; 15 cycles = 15 s: 0.177 = 164; 20 cycles = 20 s: 0.130 = 205; 25 cycles = 25 s: 0.086 = 200; 30 cycles = 30 s: 0.077 = 267]. CONCLUSION The strong correlations and high consistency between the two masticatory performance methods found in this study conclude that the two assessment methods are reliable and interchangeable. Further evaluations are warranted to arrive at a conversion formula for translation of the results between the two methods.
Collapse
Affiliation(s)
- Arnold Nrecaj
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Lisa Takeshita
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | | | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Cláudio Rodrigues Leles
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Murali Srinivasan
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Schenk N, Bukvic H, Schimmel M, Abou-Ayash S, Enkling N. One-Piece Mini Dental Implant-Retained Mandibular Overdentures: 10-Year Clinical and Radiological Outcomes of a Non-Comparative Longitudinal Observational Study. J Funct Biomater 2024; 15:99. [PMID: 38667556 DOI: 10.3390/jfb15040099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 03/30/2024] [Accepted: 04/03/2024] [Indexed: 04/28/2024] Open
Abstract
This study presents the first 10-year follow-up investigation of the implant survival and peri-implant outcomes of one-piece mini dental implants (MDIs) retaining mandibular implant overdentures (IODs), including marginal bone level alterations (ΔMBLs), clinical peri-implant parameters, and complications. Twenty participants with horizontally atrophied mandibles received complete dentures and four MDIs (diameter 1.8 mm) at baseline. The dentures were converted into IODs with O-ring attachments. The 10-year follow-up comprised a radiological assessment of ΔMBLs, peri-implant parameters, as well as biological and technical complications. Results from a 10-year follow-up of 14 participants showed a 100% implant survival rate for all 56 implants. The mean ΔMBL after 10 years was -1.12 ± 0.80 mm, with 49 implants classified as successful (ΔMBL < 2 mm) and 7 implants with satisfactory survival (ΔMBL 2-4 mm). Time after implant placement significantly influenced ΔMBL, with stable MBLs after 5 years. The prosthetic survival rate after 10 years was 93%. ΔMBLs were not influenced by implant position or gender but were significantly smaller in subjects older than 65 years. Conclusively, one-piece MDIs with O-ring attachments offer a reliable treatment option for horizontally atrophied mandibles after 10 years, with high implant and prosthetic survival rates, potentially benefiting from advanced age regarding peri-implant bone stability.
Collapse
Affiliation(s)
- Nicole Schenk
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Hristina Bukvic
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University of Geneva, 1205 Geneva, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Norbert Enkling
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Medical Faculty, University of Bonn, 53113 Bonn, Germany
| |
Collapse
|
3
|
Gama LT, Bezerra AP, Schimmel M, Rodrigues Garcia RCM, de Luca Canto G, Gonçalves TMSV. Clinical performance of polymer frameworks in dental prostheses: A systematic review. J Prosthet Dent 2024; 131:579-590. [PMID: 35422333 DOI: 10.1016/j.prosdent.2022.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 03/07/2022] [Accepted: 03/07/2022] [Indexed: 12/11/2022]
Abstract
STATEMENT OF PROBLEM High-performance polymers including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) have been used as substitutes for metal frameworks in dental prostheses. However, the clinical performance of polymer-based frameworks is still uncertain. PURPOSE The purpose of this systematic review was to compare the clinical performance of PEEK and PEKK with that of metal frameworks for different dental prostheses. MATERIAL AND METHODS This review follows the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six databases and non-peer-reviewed literature (without language or follow-up restrictions) were searched for studies conducted before February 2022. Only clinical studies, either randomized clinical trials (RCTs) or nonrandomized clinical trials (N-RCTs), comparing the clinical performance of polymer and metal frameworks were included. The risk of bias and certainty of the evidence were assessed with the RoB 2.0, ROBINS-I, and GRADE. Biologic (plaque and gingival indices, probing depth, bleeding scores, implant stability quotient, marginal bone loss) and mechanical outcomes (ridge base relation, prosthetic marginal gap, and fracture) were assessed. RESULTS Only 9 studies (7 RCTs and 2 N-RCTs) were included, all with moderate to serious risk of bias and low to very low certainty of evidence. No meta-analysis was possible, but qualitative analysis revealed lower plaque and gingival indices, probing depth, and marginal bone loss, with higher survival rates for implant-supported fixed prostheses and overdentures fabricated with PEEK than for metal frameworks. No significant differences were found between groups for removable partial dentures. The marginal fit of PEEK frameworks was also better for single crowns. Three fractures were reported in the 3 PEKK fixed dental prostheses with cantilevers. CONCLUSIONS PEEK and PEKK seem to be promising materials for dental prostheses, with acceptable response from the periodontal tissue. However, further well-designed studies are necessary to better understand their clinical and long-term limitations.
Collapse
Affiliation(s)
- Lorena Tavares Gama
- PhD student, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Adriana Pinto Bezerra
- PhD student, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | - Martin Schimmel
- Full Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern (UNIBE), Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva (UNIGE), Geneva, Switzerland
| | - Renata Cunha Matheus Rodrigues Garcia
- Full Professor, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Graziela de Luca Canto
- Full Professor, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | | |
Collapse
|
4
|
Çakmak G, Cuellar AR, Donmez MB, Abou-Ayash S, Lu WE, Schimmel M, Yilmaz B. Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures. J Prosthet Dent 2024; 131:718-725. [PMID: 35636984 DOI: 10.1016/j.prosdent.2022.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 04/18/2022] [Accepted: 04/18/2022] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D printed fixed partial dentures (FPDs) is lacking. PURPOSE The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing. MATERIAL AND METHODS The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 μm (n=10), 50 μm (n=10), and 100 μm (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (α=.05). RESULTS The 100-μm-layer thickness interim FPDs showed the greatest overall (P≤.015), external (P≤.021), and intaglio occlusal (P≤.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P≥.108). The differences between the 50-μm-layer thickness and 100-μm-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-μm-layer thickness and 50-μm-layer thickness interim FPDs for each surface tested were not statistically significant (P≥.108). CONCLUSIONS The printing layer thickness had a significant effect on the trueness of the additively manufactured interim FPDs. However, subtractively manufactured interim FPDs presented higher trueness than those additively manufactured, regardless of the printing layer thickness.
Collapse
Affiliation(s)
- Gülce Çakmak
- Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Alfonso Rodriguez Cuellar
- Professor, Department of Periodontology, Clinica Dental Rodriguez Dental Clinic, Mexico City, Mexico
| | - Mustafa Borga Donmez
- Assistant Professor, Department of Prosthodontics, Istinye University Faculty of Dentistry, Istanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Wei-En Lu
- PhD student, Division of Biostatistics, The Ohio State University College of Public Health, Columbus, Ohio
| | - Martin Schimmel
- Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Researcher, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| |
Collapse
|
5
|
Molinero-Mourelle P, Abou-Ayash S, Brägger U, Schimmel M, Özcan M, Yilmaz B, Buser R, Al-Haj Husain N. Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study. J Mech Behav Biomed Mater 2024; 151:106395. [PMID: 38244420 DOI: 10.1016/j.jmbbm.2024.106395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 01/08/2024] [Accepted: 01/08/2024] [Indexed: 01/22/2024]
Abstract
OBJECTIVES To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Switzerland
| | - Mutlu Özcan
- Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH, USA
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Nadin Al-Haj Husain
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
6
|
Çakmak G, Weber FA, Donmez MB, Kahveci Ç, Schimmel M, Yilmaz B. Effect of coffee thermocycling on the surface roughness and stainability of denture base materials with different chemical compositions manufactured with additive and subtractive technologies. J ESTHET RESTOR DENT 2024; 36:453-459. [PMID: 37705502 DOI: 10.1111/jerd.13136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 08/23/2023] [Accepted: 08/29/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE To evaluate the effect of coffee thermocycling (CTC) on the surface roughness (Ra ) and stainability of denture base materials with different chemical compositions fabricated by using additive and subtractive manufacturing. MATERIALS AND METHODS Disk-shaped specimens were additively (FREEPRINT denture, AM) or subtractively (G-CAM, GSM and M-PM, SM) fabricated from three pink denture base materials in different chemical compositions (n = 10). Ra was measured before and after polishing, while color coordinates were measured after polishing. Specimens were subjected to CTC (5000 cycles) and measurements were repeated. Color differences (ΔE00 ) after CTC were calculated. Ra among different time intervals within materials was evaluated by using repeated measures analysis of variance (ANOVA), while 1-way ANOVA was used to evaluate the Ra of different materials within each time interval and the ΔE00 values. Color coordinates within each material were compared by using paired samples t-tests (α = 0.05). RESULTS Ra before polishing was the highest for all materials (p < 0.001), while SM had its lowest Ra after CTC and AM had its lowest Ra after polishing (p ≤ 0.008). Before polishing, AM had the highest Ra among the materials (p < 0.001). After polishing, SM had higher Ra than AM (p < 0.001). After CTC, GSM had the lowest Ra (p ≤ 0.048). SM had the lowest (p ≤ 0.031) and AM had the highest (p < 0.001) ΔE00 . CTC decreased the a* and b* values of SM and AM (p ≤ 0.017), and increased the L* values of AM (p < 0.001). CONCLUSIONS Polishing significantly reduced the surface roughness of all materials. CTC did not increase the surface roughness of materials above the clinically acceptable threshold. Only AM had perceptible color change when previously reported threshold values for denture base materials were considered. CLINICAL SIGNIFICANCE Tested denture base materials may have similar surface stability after coffee thermocycling. However, subtractively manufactured denture base materials may have improved color stability when subjected to long-term coffee consumption.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Franziska Alexandra Weber
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Zahnarztpraxis Landmesser, Spiez, Switzerland
- Zahnarztpraxis Krebs, Oey, Switzerland
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| | | | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
7
|
Yilmaz B, Gouveia D, Schimmel M, Lu WE, Özcan M, Abou-Ayash S. Effect of adhesive system, resin cement, heat-pressing technique, and thermomechanical aging on the adhesion between titanium base and a high-performance polymer. J Prosthet Dent 2024; 131:468-474. [PMID: 35513915 DOI: 10.1016/j.prosdent.2022.03.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/21/2022] [Accepted: 03/21/2022] [Indexed: 11/25/2022]
Abstract
STATEMENT OF PROBLEM Even though polyetheretherketone (PEEK) has become popular for various prosthetic indications, a standard adhesive protocol to bond the PEEK to titanium bases has not been yet established. How the heat-pressing technique performs in this respect is also not clear. PURPOSE The purpose of this in vitro study was to investigate the effect of an adhesive system-cement combination, the heat-pressing technique, and thermomechanical aging on the retention force between titanium bases and PEEK specimens. MATERIAL AND METHODS Sixty 9×11×20-mm PEEK specimens with a titanium base slot integrated into the design were milled to simulate an implant-supported PEEK framework for a cantilevered fixed prosthesis. The specimens were assigned to 8 groups (n=10) according to the titanium base primer (MKZ or Monobond) and resin cement (DTK or Multilink hybrid) used and with or without thermomechanical aging. Twenty PEEK specimens were directly heat-pressed on titanium bases, and half of the specimens were not subjected to thermomechanical aging (n=10). For nonaged groups, the PEEK specimen complex was tightened to an implant analog and secured on a custom-made pull-off device. Retention forces were measured by using the pull-off tensile test in a universal testing machine, and the maximum tensile bond strength (MPa) was calculated. The aged groups were subjected to 5000 cycles of thermal aging (5 °C to 55 °C), and the specimens were clamped to load the extension (cantilever) for 1 200 000 cycles with 120 N and 200 N at 1.5-Hz frequency. After aging, the pull-off test was performed for those specimens that survived thermomechanical aging. A nonparametric Kruskal-Wallis test was used to determine whether there was a difference among the groups, followed by pairwise Wilcoxon rank tests with Bonferroni correction. The Wilcoxon rank test was used to analyze the effect of thermomechanical aging in each adhesive system-cement or heat-press group (α=.05 for all tests). RESULTS None of the specimens failed during cyclic loading. According to the Kruskal-Wallis test, the effect of the PEEK-Ti base bonding technique on the retention force in the nonaged (P=.019) and thermomechanically aged groups was significant (P=.010). In the nonaged groups, the heat-pressing technique resulted in a higher retention force than when the specimens were bonded by using the Monobond-Multilink hybrid combination (P=.031). Thermomechanical aging did not significantly affect the results (P>.241). All failures were adhesive, with cement remaining only on the Ti-bases. CONCLUSIONS All bonding protocols tested resulted in a stable bond between PEEK and Ti-bases, as all specimens survived thermomechanical aging. The heat-pressing technique resulted in mean bond strength values similar to those obtained with the tested adhesive system-cement combinations with 1 exception; the nonaged heat-pressed groups presented higher bond strength than the Monobond-Multilink hybrid combination. Failure types indicated that the weaker bond was between the PEEK and the cements tested rather than between the titanium base and the cements, regardless of the adhesive system-cement combination.
Collapse
Affiliation(s)
- Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Diogo Gouveia
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland; Senior Lecturer, Extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Wei-En Lu
- PhD Candidate, Division of Biostatistics, The Ohio State University College of Public Health, Columbus, Ohio
| | - Mutlu Özcan
- Professor and Head, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head, Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| |
Collapse
|
8
|
Elbashti ME, Aswehlee A, Sumita Y, Schimmel M, Abou-Ayash S, Molinero-Mourelle P. An integration protocol for aligning intraoral scans to facial scans using the nasal geometry reference in a fully dentate patient. Quintessence Int 2024; 55:140-146. [PMID: 37800690 DOI: 10.3290/j.qi.b4478927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 10/07/2023]
Abstract
Advanced digital technologies have rapidly been integrated into prosthodontics to improve the digital workflow for prosthetic rehabilitation. The integration of 3D datasets acquired from various imaging sources such as intraoral scanners and facial optical scanners allows the creation of virtual patients to perform presurgical simulation and prosthetic rehabilitation. The presented technique introduced a straightforward protocol for aligning intraoral scans (Trios 4, 3Shape) to optical face scans (Face Hunter, Zirkonzahn) using a global best-fit algorithm of 3D evaluation software (GOM Inspect). Nasal geometry data were used as the matching reference to produce virtual dental patients. This integration protocol ensured that the intraoral scanner (Trios 4, 3Shape) was used not only to scan dental arches but also used effectively to scan the nose. These scans along with professional facial scans can be successfully aligned to produce virtual dental patients. As only a single fully dentate patient case with an alignment deviation of 243.6 µm was used, further research to evaluate the accuracy of this protocol is needed.
Collapse
|
9
|
Dönmez MB, Wepfer AB, Güven ME, Çakmak G, Schimmel M, Yilmaz B. Dimensional Stability of Additively Manufactured Diagnostic Maxillary Casts Fabricated with Different Model Resins. INT J PROSTHODONT 2024; 37:119-126. [PMID: 38498863 DOI: 10.11607/ijp.8877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
PURPOSE To evaluate the effect of model resin type and time interval on the dimensional stability of additively manufactured diagnostic casts. MATERIALS AND METHODS Ten irreversible hydrocolloid impressions and 10 impressions from an intraoral scanner were made from a reference maxillary stone cast, which was also digitized with a laboratory scanner. Conventional impressions were poured in type III stone (SC), while digital impressions were used to additively manufacture casts with a nanographene-reinforced model resin (GP) or a model resin (DM). All casts were digitized with the same laboratory scanner 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Cast scans were superimposed over the reference cast scan to evaluate dimensional stability. Data were analyzed with Bonferroni-corrected repeated measures ANOVA (α = .05). RESULTS The interaction between the main factors (material type and time interval) affected anterior teeth deviations, while the individual main factors affected anterior teeth and entire-cast deviations (P ≤ .008). Within anterior teeth, DM had the lowest deviations at T3, and GP mostly had lower values at T2 and lower deviations at T3 than at T0 (P ≤ .041). SC had the highest pooled anterior teeth deviations, and GP had the highest pooled entire cast deviations (P < .001). T3 had lower pooled anterior teeth deviations than at T0, T1, and T4, and higher pooled entire cast deviations than T1 were demonstrated (P ≤ .027). CONCLUSIONS The trueness of nanographene-reinforced casts was either similar to or higher than that of other casts. Dimensional changes were acceptable during the course of 1 month.
Collapse
|
10
|
Çakmak G, Steigmeier D, Güven ME, Yilmaz D, Schimmel M, Yoon HI, Yilmaz B. Fabrication Trueness, Intaglio Surface Adaptation, and Marginal Integrity of Resin-Based Onlay Restorations Fabricated by Additive and Subtractive Manufacturing. INT J PROSTHODONT 2024; 37:99-107. [PMID: 37988421 DOI: 10.11607/ijp.8802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
PURPOSE To evaluate the fabrication trueness, intaglio surface adaptation, and marginal integrity of resin-based onlay restorations made via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS An onlay restoration was designed (DentalCAD Galway 3.0) and saved as an STL file to generate a design STL file (DO-STL). Using this design, 45 onlays were fabricated either with AM (3D-printed resin for definitive [AM-D; Tera Harz TC-80DP] and interim [AM-I; Freeprint temp] restorations) or SM (composite resin, Tetric CAD) technologies. Onlays were scanned with an intraoral scanner (CEREC Primescan SW 5.2), and the scans were saved as test STL files (TO-STLs). For trueness evaluation, TO-STLs were superimposed over the DO-STL, and root mean square (RMS) values of overall and intaglio surfaces were measured (Geomagic Control X). For the intaglio surface adaptation and marginal integrity, a triple-scan protocol was performed. Kolmogorov-Smirnov, one-way ANOVA, and post-hoc Tukey honestly significant difference tests were used to analyze data (α = .05). RESULTS RMS values of intaglio and overall surfaces, intaglio adaptation, and marginal integrity varied among test groups (P < .001). AM-D had the greatest overall surface RMS (P < .001), while SM had the greatest intaglio surface RMS (P < .001). SM had the highest average distance deviations for intaglio surface adaptation and marginal integrity, whereas AM-D had the lowest (P < .001). CONCLUSIONS AM-D onlays showed lower overall trueness than AM-I onlays and SM definitive onlays. However, AM-D onlays presented high intaglio surface trueness, intaglio surface adaptation, and marginal integrity.
Collapse
|
11
|
Parisius KGH, Verhoeff MC, Lobbezoo F, Avivi-Arber L, Duyck J, Hirano H, Iijima K, Janssens B, Kossioni A, Lin CS, McKenna G, Müller F, Schimmel M, Visser A, Watanabe Y, Gobbens RJJ. Towards an operational definition of oral frailty: A e-Delphi study. Arch Gerontol Geriatr 2024; 117:105181. [PMID: 37713933 DOI: 10.1016/j.archger.2023.105181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 09/01/2023] [Accepted: 09/04/2023] [Indexed: 09/17/2023]
Abstract
OBJECTIVES Building upon our recently developed conceptual definition of oral frailty (the age-related functional decline of orofacial structures), this e-Delphi study aims to develop an operational definition of oral frailty by identifying its components. METHODS We used a modified e-Delphi study to reach a consensus among international experts on the components of oral frailty. Twelve out of fifteen invited experts in the field of gerodontology participated. Experts responded to three rounds of an online 5-point scale questionnaire of components to be included or excluded from the operational definition of oral frailty. After each round, scores and rationales were shared with all experts, after which they could revise their position. A consensus was reached when at least 70% of the experts agreed on whether or not a component should be included in the operational definition of oral frailty. RESULTS The experts achieved a high level of agreement (80 - 100%) on including eight components of oral frailty and excluding nineteen. The operational definition of oral frailty should include the following components: 1) difficulty eating hard or tough foods, 2) inability to chew all types of foods, 3) decreased ability to swallow solid foods, 4) decreased ability to swallow liquids, 5) overall poor swallowing function, 6) impaired tongue movement, 7) speech or phonatory disorders, and 8) hyposalivation or xerostomia. CONCLUSION This e-Delphi study provided eight components that make up the operational definition of oral frailty. These components are the foundation for the next stage, which involves developing an oral frailty assessment tool.
Collapse
Affiliation(s)
- Karl G H Parisius
- Department of Orofacial Pain and Dysfunction, Academic Centre for Dentistry Amsterdam, ACTA, University of Amsterdam, The Netherlands; Faculty of Health, Sports and Social Work, Inholland University of Applied Sciences, The Netherlands.
| | - Merel C Verhoeff
- Department of Orofacial Pain and Dysfunction, Academic Centre for Dentistry Amsterdam, ACTA, University of Amsterdam, The Netherlands
| | - Frank Lobbezoo
- Department of Orofacial Pain and Dysfunction, Academic Centre for Dentistry Amsterdam, ACTA, University of Amsterdam, The Netherlands
| | | | - Joke Duyck
- Department of Oral Health Sciences, KU Leuven, Belgium
| | - Hirohiko Hirano
- Tokyo Metropolitan Institute for Geriatrics and Gerontology, Japan
| | - Katsuya Iijima
- Institute for Future Initiatives, Institute of Gerontology, The University of Tokyo, Japan
| | - Barbara Janssens
- Department of Oral Health Sciences, Gerodontology, ELOHA (Equal Lifelong Oral Health for All) research group, Ghent University, Belgium
| | - Anastassia Kossioni
- Division of Gerodontology, Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Greece
| | - Chia-Shu Lin
- Department of Dentistry, National Yang Ming Chiao Tung University, Taiwan
| | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Northern Ireland United Kingdom
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthdontics, University Clinics of Dental Medicine, University of Geneva, Switzerland
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthdontics, University Clinics of Dental Medicine, University of Geneva, Switzerland; Department of Reconstructive Dentistry and Gerodontology, school of Dental Medicine, University of Bern, Switzerland
| | - Anita Visser
- Department of Gerodontology, Center for Dentistry and Oral Hygiene, University of Groningen, The Netherlands; University Medical Center Groningen, The Netherlands; Department for Gerodontology, College of Dental Sciences, Radboud University Nijmegen Medical Centre, The Netherlands
| | - Yutaka Watanabe
- Gerodontology, Department of Oral Health Science, Faculty of Dental Medicine, Hokkaido University, Hokkaido, Japan
| | - Robbert J J Gobbens
- Faculty of Health, Sports and Social Work, Inholland University of Applied Sciences, The Netherlands; Zonnehuisgroep Amstelland, The Netherlands; Department Family Medicine and Population Health, Faculty of Medicine and Health Sciences, University of Antwerp, Belgium; Department of Tranzo Academic Centre for Transformation in Care and Welfare, Faculty of Behavioural and Social Sciences, Tilburg University, The Netherlands
| |
Collapse
|
12
|
Çakmak G, Chebaro J, Donmez MB, Yılmaz D, Yoon HI, Kahveci Ç, Schimmel M, Yilmaz B. Influence of intraoral scanner and finish line location on the fabrication trueness and margin quality of additively manufactured laminate veneers fabricated with a completely digital workflow. J Prosthet Dent 2024; 131:313.e1-313.e9. [PMID: 37978007 DOI: 10.1016/j.prosdent.2023.10.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 10/23/2023] [Accepted: 10/23/2023] [Indexed: 11/19/2023]
Abstract
STATEMENT OF PROBLEM Knowledge of the fabrication trueness and margin quality of additively manufactured (AM) laminate veneers (LVs) when different intraoral scanners (IOSs) and finish line locations are used is limited. PURPOSE The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM LVs with different finish line locations digitized by using different IOSs. MATERIAL AND METHODS An LV preparation with a subgingival (sub), equigingival (equi), or supragingival (supra) finish line was performed on 3 identical maxillary right central incisor typodont teeth. Each preparation was digitized by using 2 IOSs, (CEREC Primescan [PS] and TRIOS 3 [TS]), and a reference LV for each finish line-IOS pair (n=6) was designed. A total of 90 LVs were fabricated by using these files and urethane acrylate-based definitive resin (Tera Harz TC-80DP) (n=15). Each LV was then digitized by using PS to evaluate fabrication trueness (overall, external, intaglio, and marginal surfaces). Each LV was also qualitatively evaluated under a stereomicroscope (×60), and the cervical and incisal margin quality was graded. Fabrication trueness and cervical margin quality were evaluated by using 2-way analysis of variance, while Kruskal-Wallis and Mann Whitney-U tests were used to evaluate incisal margin quality (α=.05). RESULTS The interaction between the IOS type and the finish line location affected measured deviations at each surface (P≤.020). PS-sub and TS-supra had higher overall trueness than their counterparts. and the subgingival finish line resulted in the lowest trueness (P≤.005). PS and the subgingival finish line led to the lowest trueness of the external surface (P≤.001). TS-sub had the lowest intaglio surface trueness among the TS subgroups, and PS-sub had higher trueness than TS-sub (P<.001). PS-sub and PS-supra had higher marginal surface trueness than their TS counterparts (P<.001). TS resulted in higher cervical margin quality (P=.001). CONCLUSIONS Regardless of the IOS tested, subgingival finish lines resulted in the lowest trueness. The effect of IOS on the measured deviations varied according to the surface evaluated and finish line location. The cervical margin quality of AM LVs was higher when TS was used.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Resarch Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Jad Chebaro
- Predoctoral student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and Private Practice, Bellinzona, Switzerland
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and ITI Scholar, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Deniz Yılmaz
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Hyung-In Yoon
- Associate Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; and Adjunct Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Çiğdem Kahveci
- Prosthodontist, Ordu Oral and Dental Health Center, Ordu, Turkey
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
13
|
Cho JH, Çakmak G, Yi Y, Yoon HI, Yilmaz B, Schimmel M. Tooth morphology, internal fit, occlusion and proximal contacts of dental crowns designed by deep learning-based dental software: A comparative study. J Dent 2024; 141:104830. [PMID: 38163455 DOI: 10.1016/j.jdent.2023.104830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/13/2023] [Accepted: 12/29/2023] [Indexed: 01/03/2024] Open
Abstract
OBJECTIVES This study compared the tooth morphology, internal fit, occlusion, and proximal contacts of dental crowns automatically generated via two deep learning (DL)-based dental software systems with those manually designed by an experienced dental technician using conventional software. METHODS Thirty partial arch scans of prepared posterior teeth were used. The crowns were designed using two DL-based methods (AA and AD) and a technician-based method (NC). The crown design outcomes were three-dimensionally compared, focusing on tooth morphology, internal fit, occlusion, and proximal contacts, by calculating the geometric relationship. Statistical analysis utilized the independent t-test, Mann-Whitney test, one-way ANOVA, and Kruskal-Wallis test with post hoc pairwise comparisons (α = 0.05). RESULTS The AA and AD groups, with the NC group as a reference, exhibited no significant tooth morphology discrepancies across entire external or occlusal surfaces. The AD group exhibited higher root mean square and positive average values on the axial surface (P < .05). The AD and NC groups exhibited a better internal fit than the AA group (P < .001). The cusp angles were similar across all groups (P = .065). The NC group yielded more occlusal contact points than the AD group (P = .006). Occlusal and proximal contact intensities varied among the groups (both P < .001). CONCLUSIONS Crowns designed by using both DL-based software programs exhibited similar morphologies on the occlusal and axial surfaces; however, they differed in internal fit, occlusion, and proximal contacts. Their overall performance was clinically comparable to that of the technician-based method in terms of the internal fit and number of occlusal contact points. CLINICAL SIGNIFICANCE DL-based dental software for crown design can streamline the digital workflow in restorative dentistry, ensuring clinically-acceptable outcomes on tooth morphology, internal fit, occlusion, and proximal contacts. It can minimize the necessity of additional design optimization by dental technician.
Collapse
Affiliation(s)
- Jun-Ho Cho
- Department of Prosthodontics, Seoul National University Dental Hospital, Seoul, Republic of Korea
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Yuseung Yi
- Department of Prosthodontics, Seoul National University Dental Hospital, Seoul, Republic of Korea
| | - Hyung-In Yoon
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea.
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH, USA
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
14
|
Borga Donmez M, Çakmak G, Schimmel M, Yilmaz B. Implementation of triple-scan protocol to evaluate the fit of complete-arch implant-supported fixed prostheses. J Prosthodont 2024. [PMID: 38291720 DOI: 10.1111/jopr.13830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 01/18/2024] [Indexed: 02/01/2024] Open
Abstract
Passive fit is essential for multiple-unit implant-supported prostheses. Conventional methods to assess the passivity of complete-arch implant-supported prostheses do not allow 3-dimensional (3D) visualization and quantification of misfit. This report describes the marginal and internal fit evaluation of a complete-arch implant-supported prosthesis by using the triple-scan protocol involving a scanner and a 3D analysis freeware. This technique allows researchers, clinicians, or dental technicians to detect and quantify 3D prosthetic misfit, which may facilitate the preparation for dental appointments and objective measurement of misfit for research studies.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| |
Collapse
|
15
|
Çakmak G, Asadolahi NW, Schimmel M, Molinero-Mourelle P, Akay C, Donmez MB, Yilmaz B. Effect of coffee thermal cycling on the surface properties and stainability of additively manufactured denture base resins in different layer thicknesses. J Prosthodont 2023. [PMID: 37968565 DOI: 10.1111/jopr.13803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 10/25/2023] [Accepted: 11/09/2023] [Indexed: 11/17/2023] Open
Abstract
PURPOSE To compare the effect of coffee thermal cycling on surface roughness (Ra), Vickers microhardness (MH), and stainability of denture base resins additively manufactured in different layer thicknesses with those of subtractively manufactured denture base materials. MATERIALS AND METHODS Eighty disk-shaped specimens (Ø10×2 mm) were fabricated from two subtractively (Merz M-PM [SM-M] and G-CAM [SM-G]) and three additively (NextDent 3D+ [50 µm, AM-N-50; 100 µm, AM-N-100], FREEPRINT Denture [50 µm, AM-F-50; 100 µm, AM-F-100], and Denturetec [50 µm, AM-S-50; 100 µm, AM-S-100]) manufactured denture base materials (n = 10). Ra measurements were performed before and after polishing by using a non-contact optical profilometer, while MH values and color coordinates were measured after polishing. Specimens were then subjected to 5000 cycles of coffee thermal cycling, all measurements were repeated, and color differences (ΔE00) were calculated. A linear mixed effect model was used to analyze Ra and MH data, while one-way analysis of variance was used to analyze ΔE00 data (α = 0.05). Ra values were further evaluated according to a clinically acceptable threshold of 0.2 µm, while ΔE00 values were evaluated according to perceptibility (1.72 units) and acceptability (4.08 units) thresholds. The interaction between the material type and the time interval affected both Ra and MH (p ≤ 0.001). Tested materials had their highest Ra before polishing (p ≤ 0.029). Before polishing, AM-F-100 had the highest, and SM-M and SM-G had the lowest Ra (p < 0.001). After polishing and after coffee thermal cycling, SM-G mostly had lower Ra than those of other materials (p ≤ 0.036). SM-G mostly had higher MH than that of other materials before and after coffee thermal cycling (p ≤ 0.025). Coffee thermal cycling reduced the MH of SM-M and increased that of AM-S-100 (p ≤ 0.024). AM-N-100 had higher ΔE00 than AM-F, AM-S-100, and SM-G (p ≤ 0.009), while AM-F and SM-G had lower ΔE00 than AM-S-50 and AM-N-50 (p ≤ 0.024). CONCLUSIONS Polishing reduced the surface roughness of all materials, whereas the effect of coffee thermal cycling was nonsignificant. Most of the tested materials had acceptable surface roughness after polishing and after coffee thermal cycling according to the reported threshold. Layer thickness only affected the microhardness of tested additively manufactured resins, which was material-dependent. Subtractively manufactured specimens mostly had high microhardness and that of nonreinforced subtractively manufactured resin decreased after coffee thermal cycling. When reported color thresholds are considered, all materials had acceptable color stability.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Nura Watson Asadolahi
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| |
Collapse
|
16
|
Atalay S, Çakmak G, Fonseca M, Schimmel M, Yilmaz B. Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials. J Prosthet Dent 2023; 130:787-795. [PMID: 35148889 DOI: 10.1016/j.prosdent.2021.12.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 12/07/2021] [Accepted: 12/07/2021] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM Which disinfection protocol provides optimal water contact angle and microhardness for computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) materials is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of different disinfection protocols (1% sodium hypochlorite, denture cleanser gel, and effervescent tablet) on the water contact angle and microhardness of different CAD-CAM PMMA denture base materials by comparing them with a heat-polymerized PMMA. MATERIAL AND METHODS Disk-shaped specimens (Ø10×2 mm) were fabricated from 3 different CAD-CAM PMMAs-AvaDent (AV), Merz M-PM (M-PM), and Polident (Poli)-and a heat-polymerized PMMA (Vynacron) (CV) (n=21). Three disinfection protocols (1% sodium hypochlorite [HC], denture cleanser gel [GEL], an effervescent tablet [TAB]) were applied to simulate 180 days of cleansing. The water contact angle and microhardness of specimens were measured before and after disinfection and compared by using a 2-way ANOVA (α=.05). RESULTS For water contact angle, material (P=.010) and disinfection protocol (P=.002) had a significant effect. The material (P<.001), disinfection protocol (P=.001), and their interaction (P<.001) significantly affected the microhardness after disinfection. When the condition after disinfection was compared with that before disinfection, the water contact angle increased significantly in all material-disinfection protocol pairs (P≤.025), and microhardness increased significantly in all material-disinfection protocol pairs (P≤.040), except for GEL- (P=.689) or TAB-applied (P=.307) AV, HC-applied M-PM (P=.219), and TAB-applied Poli (P=.159). CONCLUSIONS The material and disinfection protocol affected the water contact angle of all tested PMMAs after disinfection, resulting in more hydrophobic surfaces for heat-polymerized or CAD-CAM PMMAs. The microhardness of heat-polymerized PMMA was less than that of all CAD-CAM PMMAs after disinfection, regardless of the protocol.
Collapse
Affiliation(s)
- Sevda Atalay
- Assistant Professor, Department of Prosthodontics, Istanbul Okan University, Faculty of Dentistry, Istanbul, Turkey
| | - Gülce Çakmak
- Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Manrique Fonseca
- Senior Lecturer, Department of Reconstructive Dentistry and Gerodontology. School of Dental Medicine University of Bern, Bern, Switzerland.
| | - Martin Schimmel
- Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Researcher, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
17
|
Yilmaz B, Guo X, Schimmel M, Abou-Ayash S. Effect of industrial scanner and framework material interaction on the marginal gaps of CAD-CAM complete arch implant frameworks. J Prosthet Dent 2023; 130:723-730. [PMID: 34998580 DOI: 10.1016/j.prosdent.2021.10.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 10/18/2021] [Accepted: 10/18/2021] [Indexed: 12/27/2022]
Abstract
STATEMENT OF PROBLEM Structured-light and computed tomography industrial scanners have been used as reference scanners to measure marginal gaps between implants and superstructures. However, the effect of framework material on the scanners' ability to detect gaps and on precision has not yet been evaluated. PURPOSE The purpose of this in vitro study was to investigate the interaction between the industrial scanner and framework material on measured marginal gaps of implant-supported fixed complete arch frameworks made from titanium and polymethylmethacrylate and on the precision of scans. MATERIAL AND METHODS A completely edentulous maxillary model with 4 implants and multiunit abutments at the first molar and canine sites was digitized by using a laboratory scanner. Implant-supported frameworks were milled from titanium and polymethylmethacrylate (n=5). Each framework was secured on the left molar site abutment. The marginal gaps between the frameworks and abutment sites without a screw were measured by using an industrial structured-light scanner and an industrial computed tomography scanner. The effect of the scanner, the framework material, and their interaction on measured gaps was analyzed by applying linear regressions and weighted least square methods. The F-statistics was used with Bonferroni corrections for precision analysis (α=.05). RESULTS No significant effect of scanner, material, or their interaction was found on the marginal gaps at the canine sites. The titanium framework gaps detected by using the computed tomography scanner were greater than those detected by using the structured-light scanner at the right molar site (estimated difference in means=0.054 mm; P=.003) and overall (estimated difference in means=0.023 mm; P=.033). The structured-light scanner's precision was higher than that of the computed tomography scanner when titanium frameworks were scanned (P=.001). The computed tomography scanner's precision was higher when scanning polymethylmethacrylate frameworks than when scanning titanium frameworks (P=.03). CONCLUSIONS Framework material and industrial scanner interaction affected the measured gaps. The computed tomography scanner detected greater marginal gaps with low precision when scanning titanium frameworks than the structured-light scanner. The sample size, the use of only 2 types of materials, and a laboratory scanner to obtain the computer-aided design file should be considered when interpreting the results.
Collapse
Affiliation(s)
- Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| | - Xiaohan Guo
- PhD student, Division of Biostatistics, College of Public Health, The Ohio State University, Columbus, Ohio
| | - Martin Schimmel
- Department Head, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland; Senior Lecturer, Extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| |
Collapse
|
18
|
Quack L, Glatter S, Wegener-Panzer A, Cleaveland R, Bertolini A, Endmayr V, Seidl R, Breu M, Wendel E, Schimmel M, Baumann M, Rauchenzauner M, Pritsch M, Boy N, Muralter T, Kluger G, Makoswski C, Kraus V, Leiz S, Loehr-Nilles C, Kreth JH, Braig S, Schilling S, Kern J, Blank C, Tro Baumann B, Vieth S, Wallot M, Reindl M, Ringl H, Wandinger KP, Leypoldt F, Höftberger R, Rostásy K. Autoantibody status, neuroradiological and clinical findings in children with acute cerebellitis. Eur J Paediatr Neurol 2023; 47:118-130. [PMID: 38284996 DOI: 10.1016/j.ejpn.2023.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 10/10/2023] [Accepted: 10/13/2023] [Indexed: 01/30/2024]
Abstract
BACKGROUND Acute cerebellitis (AC) in children and adolescents is an inflammatory disease of the cerebellum due to viral or bacterial infections but also autoimmune-mediated processes. OBJECTIVE To investigate the frequency of autoantibodies in serum and CSF as well as the neuroradiological features in children with AC. MATERIAL AND METHODS Children presenting with symptoms suggestive of AC defined as acute/subacute onset of cerebellar symptoms and MRI evidence of cerebellar inflammation or additional CSF pleocytosis, positive oligoclonal bands (OCBs), and/or presence of autoantibodies in case of negative cerebellar MRI. Children fulfilling the above-mentioned criteria and a complete data set including clinical presentation, CSF studies, testing for neuronal/cerebellar and MOG antibodies as well as MRI scans performed at disease onset were eligible for this retrospective multicenter study. RESULTS 36 patients fulfilled the inclusion criteria for AC (f:m = 14:22, median age 5.5 years). Ataxia was the most common cerebellar symptom present in 30/36 (83 %) in addition to dysmetria (15/36) or dysarthria (13/36). A substantial number of children (21/36) also had signs of encephalitis such as somnolence or seizures. In 10/36 (28 %) children the following autoantibodies (abs) were found: MOG-abs (n = 5) in serum, GFAPα-abs (n = 1) in CSF, GlyR-abs (n = 1) in CSF, mGluR1-abs (n = 1) in CSF and serum. In two further children, antibodies were detected only in serum (GlyR-abs, n = 1; GFAPα-abs, n = 1). MRI signal alterations in cerebellum were found in 30/36 children (83 %). Additional supra- and/or infratentorial lesions were present in 12/36 children, including all five children with MOG-abs. Outcome after a median follow-up of 3 months (range: 1 a 75) was favorable with an mRS ≤2 in 24/36 (67 %) after therapy. Antibody (ab)-positive children were significantly more likely to have a better outcome than ab-negative children (p = .022). CONCLUSION In nearly 30 % of children in our study with AC, a range of abs was found, underscoring that autoantibody testing in serum and CSF should be included in the work-up of a child with suspected AC. The detection of MOG-abs in AC does expand the MOGAD spectrum.
Collapse
Affiliation(s)
- L Quack
- Department of Pediatric Neurology, Childreńs Hospital Datteln, University Witten/Herdecke, Datteln, Germany
| | - S Glatter
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Austria; Comprehensive Center for Pediatrics, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Vienna, Austria
| | - A Wegener-Panzer
- Department of Pediatric Radiology, Childreńs Hospital Datteln, University Witten/Herdecke, Datteln, Germany
| | - R Cleaveland
- Department of Pediatric Radiology, Childreńs Hospital Datteln, University Witten/Herdecke, Datteln, Germany
| | - A Bertolini
- Department of Pediatric Neurology, Childreńs Hospital Datteln, University Witten/Herdecke, Datteln, Germany
| | - V Endmayr
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Austria
| | - R Seidl
- Department of Pediatrics, Bethanien Hospital, Moers, Germany
| | - M Breu
- Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Vienna, Austria
| | - E Wendel
- Division of Pediatric Neurology, Department of Pediatrics, Olgahospital, Stuttgart, Germany
| | - M Schimmel
- Division of Pediatric Neurology, Clinic of Pediatrics, Augsburg University Hospital, University of Augsburg, Augsburg, Germany
| | - M Baumann
- Department of Pediatric I, Pediatric Neurology, Medical University of Innsbruck, Innsbruck, Austria
| | - M Rauchenzauner
- Department of Pediatric I, Pediatric Neurology, Medical University of Innsbruck, Innsbruck, Austria; Centre of Epilepsy for Children and Adolescents, Schoen Klinik Vogtareuth, Hospital for Neuropediatrics and Neurological Rehabilitation, Vogtareuth, Germany
| | - M Pritsch
- Department of Neuropediatrics, Children's Hospital DRK Siegen, Siegen, Germany
| | - N Boy
- Centre for Child and Adolescent Medicine, Department of General Pediatrics, Division of Neuropediatrics and Metabolic Medicine, University Hospital Heidelberg, Heidelberg, Germany
| | - T Muralter
- Centre of Epilepsy for Children and Adolescents, Schoen Klinik Vogtareuth, Hospital for Neuropediatrics and Neurological Rehabilitation, Vogtareuth, Germany
| | - G Kluger
- Centre of Epilepsy for Children and Adolescents, Schoen Klinik Vogtareuth, Hospital for Neuropediatrics and Neurological Rehabilitation, Vogtareuth, Germany; Research Institute for Rehabilitation, Transition, and Palliation, Paracelsus Medical University Salzburg, Salzburg, Austria
| | - C Makoswski
- Pediatric Neurology, Department of Pediatrics, Kinderklinik München Schwabing, School of Medicine, Technical University of Munich, Germany
| | - V Kraus
- Pediatric Neurology, Department of Pediatrics, Kinderklinik München Schwabing, School of Medicine, Technical University of Munich, Germany; Social Pediatrics, Department of Pediatrics, Technical University of Munich, Munich, Germany
| | - S Leiz
- Department of Pediatrics and Adolescent Medicine, Hospital Dritter Orden, Munich, Germany
| | - C Loehr-Nilles
- Department of Neuropediatrics, Klinikum Mutterhaus der Borromäerinnen, Trier, Germany
| | - J H Kreth
- Department of Neuropediatrics, Social Pediatric Center, Klinikum Leverkusen, Leverkusen, Germany
| | - S Braig
- Department of Pediatrics, Klinikum Bayreuth, Bayreuth, Germany
| | - S Schilling
- Department of Neuropediatrics, Clinic of Pediatrics, Barmherzige Brüder St. Hedwig Hospital, Regensburg, Germany
| | - J Kern
- Department of Pediatric Neurology and Developmental Medicine, University Children's Hospital Tübingen, Germany
| | - C Blank
- Department of Pediatric Neurology, Children's Hospital St. Marien, Landshut, Germany
| | - B Tro Baumann
- Department of Neuropediatrics, Children's Hospital DRK Siegen, Siegen, Germany
| | - S Vieth
- Department of Pediatrics, University Medical Center Schleswig Holstein, Kiel, Germany
| | - M Wallot
- Department of Pediatrics, Bethanien Hospital, Moers, Germany
| | - M Reindl
- Clinical Department of Neurology, Medical University of Innsbruck, Austria
| | - H Ringl
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Austria; Department of Radiology, Klinik Donaustadt, Vienna, Austria
| | - K P Wandinger
- Institute of Clinical Chemistry, University Hospital Schleswig-Holstein, Kiel/Lübeck, Germany
| | - F Leypoldt
- Institute of Clinical Chemistry, University Hospital Schleswig-Holstein, Kiel/Lübeck, Germany; Department of Neurology, University Hospital Schleswig-Holstein, Kiel, Germany
| | - R Höftberger
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Austria; Comprehensive Center for Clinical Neurosciences and Mental Health, Medical University of Vienna, Vienna, Austria.
| | - K Rostásy
- Department of Pediatric Neurology, Childreńs Hospital Datteln, University Witten/Herdecke, Datteln, Germany.
| |
Collapse
|
19
|
Çakmak G, Güven ME, Donmez MB, Kahveci Ç, Schimmel M, Abou-Ayash S, Yilmaz B. Effect of internal connection type and screw channel angle on the screw stability of anterior implant-supported zirconia crowns. Clin Oral Implants Res 2023; 34:1248-1256. [PMID: 37578653 DOI: 10.1111/clr.14165] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/14/2023] [Accepted: 08/02/2023] [Indexed: 08/15/2023]
Abstract
OBJECTIVES To investigate the effect of implant-abutment connection and screw channel angle on screw stability by comparing a newly introduced and an established connection, before and after cyclic loading. MATERIALS AND METHODS Implants (N = 44) with Torcfit (TF) or Crossfit (CF) connection were divided to be restored with a straight (CFS and TFS) or an angled screw access channel (CFA and TFA) titanium-base abutment (n = 11). CFA and TFA received screw-retained crowns, whereas CFS and TFS received hybrid zirconia abutments and cement-retained crowns. The initial torque value (ITV) of each complex (ITVI ) and removal torque value (RTV) after 24 h (RTVI ) were measured. Screws were replaced with new ones, ITVs were recorded again (ITVF ), and crowns were cyclically loaded (2.4 million cycles, 98 N) to measure RTVs again (RTVF ). Percentage torque loss was calculated. Data were analyzed (α = 0.05). RESULTS ITVs were similar among groups (p ≥ .089). CF led to higher RTVs (p ≤ .002), while CFS had higher RTVI than CFA (p = .023). After 24 h, CFS had lower percentage torque loss than TF, while CFA had lower percentage torque loss than TFA (p ≤ .011). After cyclic loading, CF led to lower percentage torque (p < .001). CONCLUSION The implant-abutment connection affected the removal torque values. However, no screw loosening occurred during cyclic loading, which indicated a stable connection for all groups. Screw access channel angle did not affect screw stability after cyclic loading.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mehmet Esad Güven
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey
| | | | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| |
Collapse
|
20
|
Elbashti M, Molinero-Mourelle P, Aswehlee A, Bornstein MM, Abou-Ayash S, Schimmel M, Ella B, Naveau A. Effect of triangular mesh resolution on the geometrical trueness of segmented CBCT maxillofacial data into STL format. J Dent 2023; 138:104722. [PMID: 37742810 DOI: 10.1016/j.jdent.2023.104722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Revised: 08/28/2023] [Accepted: 09/21/2023] [Indexed: 09/26/2023] Open
Abstract
OBJECTIVES To determine the optimal level of mesh reduction that would maintain acceptable levels of geometrical trueness while also minimizing the impact on other parameters such as file size and processing time. METHODS Intraoral and extraoral maxillofacial defects were created on 8 cadaver heads and scanned by using a CBCT scanner (NewTom 3D Imaging, Verona). DICOM data were segmented to produce head (n=8) and skull models (n=8) saved as standard tessellation language (STL) files. A further processing of head models was preformed to produce face (n=8) and ear models (n=8). A mesh reduction process was performed for each STL model (reference, R0) by generating 50% (R1), 75% (R2), and 90% (R3) reductions. The 3 datasets were compared to the R0 file using 3D evaluation software (GOM Inspect) using a global best-fit algorithm, to calculate the root mean square (RMS) deviations. Statistical analyses were performed at a level of significance of α=0.05. RESULTS There was no 3D deviation after the 50% triangular mesh reduction in the 4 datasets. Minor 3D deviations were observed after 75% reduction, in all groups. After 90% reduction, higher 3D deviations were observed, and especially in head and skull. Statistically significant increase in 3D deviations was observed with higher degrees of mesh reduction (p < 0.001). CONCLUSION The resolution of CBCT-based maxillofacial defect models can be reduced up to 50%, with neglectable concern to inaccuracy. CLINICAL SIGNIFICANCE Accurate maxillofacial models can be obtained from CBCT DICOM files after segmentation and export as STL files, even when the mesh resolution is reduced up to 50%. This information can be valuable for practitioners and researchers working with 3D models of maxillofacial defects.
Collapse
Affiliation(s)
- Mahmoud Elbashti
- Department of Maxillofacial Prosthetics, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan.
| | - Pedro Molinero-Mourelle
- Department of Conservative Dentistry and Orofacial Prosthodontics, Complutense University of Madrid, Madrid, Spain; Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| | - Amel Aswehlee
- Department of Dental Technology, University of Tripoli, Tripoli, Libya.
| | - Michael M Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland.
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland, and Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Switzerland.
| | - Bruno Ella
- Oral Surgery Department, School of Surgery, Bordeaux University Hospital, Bordeaux, France.
| | - Adrien Naveau
- Department of Prosthodontics, University of Bordeaux, Bordeaux, France.
| |
Collapse
|
21
|
Molinero-Mourelle P, Peter L, Gaviria AS, Fonseca M, Schimmel M, Katsoulis J. Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study. Acta Odontol Scand 2023; 81:591-596. [PMID: 37319413 DOI: 10.1080/00016357.2023.2223715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/05/2023] [Accepted: 06/06/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. METHODS Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values <5% were considered statistically significant. RESULTS The tactile assessment showed a mean total sensitivity for the Straumann and Nobel Biocare systems of 83% and 80% with a used probe, and 91% and 92% with a new probe, respectively. The mean total specificities were 33% and 20% with a used probe and 17% and 3% with a new probe, respectively. No statistical significance was observed between novice and expert clinicians concerning their tactile assessment ability. CONCLUSIONS The ability to detect a perfect fit (specificity) with a probe was very poor for both implant systems and impaired with the use of a new probe. The use of a new probe improved the gap detection ability (sensitivity) significantly at the expense of the specificity. A combination of additional chairside techniques with training and calibration could improve clinicians' ability to correctly assess the fit/misfit at the implant-abutment interface.
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Conservative Dentistry and Orofacial Prosthodontics, Complutense University of Madrid, Madrid, Spain
| | - Lukas Peter
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ana Sol Gaviria
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Joannis Katsoulis
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Preventive and Restorative Sciences, Robert Schattner Center, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
22
|
Schimmel M, Araujo M, Abou-Ayash S, Buser R, Ebenezer S, Fonseca M, Heitz-Mayfield LJ, Holtzman LP, Kamnoedboon P, Levine R, McKenna G, Maniewicz S, Matarazzo F, Mattheos N, Papaspyridakos P, De Souza AB, Srinivasan M, Stilwell C, Weber HP. Group 4 ITI Consensus Report: Patient benefits following implant treatment in partially and fully edentulous patients. Clin Oral Implants Res 2023; 34 Suppl 26:257-265. [PMID: 37750516 DOI: 10.1111/clr.14145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/07/2023] [Accepted: 07/11/2023] [Indexed: 09/27/2023]
Abstract
OBJECTIVES The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b) improvement in orofacial function, and (c) preservation of orofacial tissues in partially and fully edentulous patients following provision of implant-retained/supported dental prostheses were addressed. MATERIALS AND METHODS Three systematic reviews formed the basis for discussion. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary of the 7th ITI Consensus Conference, taking place in 2023 in Lisbon, Portugal. RESULTS Edentulous patients wearing complete dentures (CD) experience substantial improvements in overall dPROs and orofacial function following treatment with either complete implant-supported fixed dental prostheses (CIFDP) or implant overdentures (IODs). With respect to dPROs, mandibular IODs retained by two implants are superior to IODs retained by one implant. However, increasing the number of implants beyond two, does not further improve dPROs. In fully edentulous patients, rehabilitation with CIFDP or IOD is recommended to benefit the preservation of alveolar bone and masseter muscle thickness. CONCLUSIONS Completely edentulous patients benefit substantially when at least the mandible is restored using an CIFDP or an IOD compared to CD. In fully edentulous patients, implant prostheses are the best option for tooth replacement. The availability of this treatment modality should be actively promoted in all edentulous communities, including those with limited access and means.
Collapse
Affiliation(s)
- Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Mauricio Araujo
- Department of Dentistry, State University of Maringá, Maringá, Brazil
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Lucrezia Paterno Holtzman
- Department of Periodontics and Prosthodontics, Eastman Dental Hospital, University Policlinic "La Sapienza", Rome, Italy
| | - Porawit Kamnoedboon
- Clinic of General, Special Care, and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
- Chulalongkorn University, Bangkok, Thailand
| | - Robert Levine
- Kornberg School of Dentistry at Temple University, Philadelphia, Pennsylvania, USA
| | - Gerry McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Flavia Matarazzo
- Department of Dentistry, State University of Maringá, Maringá, Brazil
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Panos Papaspyridakos
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| | | | - Murali Srinivasan
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Clinic of General, Special Care, and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Charlotte Stilwell
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Private Practice, London, UK
| | - Hans Peter Weber
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| |
Collapse
|
23
|
Reissmann DR, Schimmel M, Kraus D, Stoilov M, Srinivasan M, Enkling N. IMPACT OF LOADING PROTOCOL OF 2-IMPLANT BAR-RETAINED MANDIBULAR OVERDENTURES ON ORAL HEALTH-RELATED QUALITY OF LIFE: A RANDOMIZED CONTROLLED TRIAL. J Evid Based Dent Pract 2023; 23:101891. [PMID: 37689447 DOI: 10.1016/j.jebdp.2023.101891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 04/10/2023] [Accepted: 05/10/2023] [Indexed: 09/11/2023]
Abstract
OBJECTIVES Aim was to assess whether immediate loading (IL) is more effective than delayed loading (DL) for 2-implant bar-retained mandibular overdentures in terms of oral health-related quality of life (OHRQoL) improvement over a period of 24-month. METHODS In this randomized controlled trial, 32 edentulous patients (mean age: 65.7 ± 10.6 years, 50.0% female) were included. Potential participants had to be unsatisfied with the retention of their current mandibular complete denture and demanded implant treatment for inclusion in the study. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP) at baseline before treatment and 1, 3, 6, 12, and 24 months after implant loading and insertion of implant-retained bars for overdenture support. A mixed-effects model with patients as random effect and an unstructured covariance matrix was developed to address repeated outcome measurement. RESULTS Patients' OHRQoL impairment at baseline was substantial indicated by mean OHIP summary score of 45.1 points. OHIP summary scores decreased substantially from baseline to 1-month follow-up to a mean of 33.5 points (P = .020). OHRQoL further improved during study period indicated by OHIP summary score of 25.7 points at 24-month follow-up. Raw treatment effects (IL vs. DL) ranged from -1.2 OHIP points for 12-month follow-up to 5.8 OHIP points for 24-month follow-up. Assuming constant treatment and time effects, treatment effect was small and not statistically significant (-0.7 OHIP points; P= .918). CONCLUSION A 2-implant bar-retained mandibular overdentures substantially improves OHRQoL over a period of at least 24 months. There seems to be no significant effect of implant loading protocol.
Collapse
Affiliation(s)
- Daniel R Reissmann
- Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Freiburg, Freiburg, Germany; Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Dominik Kraus
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University of Bonn, Bonn, Germany
| | - Milan Stoilov
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University of Bonn, Bonn, Germany
| | - Murali Srinivasan
- Clinic of General, Special care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland; Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Norbert Enkling
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Preclinical Education and Dental Material Science, University of Bonn, Bonn, Germany
| |
Collapse
|
24
|
Çakmak G, Hess JA, Dönmez MB, Yılmaz D, Alhotan A, Schimmel M, Peutzfeldt A, Yilmaz B. Effect of polishing and denture cleansers on the surface roughness of new-generation denture base materials and their color change after cleansing. J Prosthodont 2023. [PMID: 37624691 DOI: 10.1111/jopr.13755] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 07/20/2023] [Accepted: 08/21/2023] [Indexed: 08/27/2023] Open
Abstract
PURPOSE To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra ) of new-generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing. MATERIAL AND METHODS One hundred and fifty disk-shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00 ). Two-way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material-time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two-way ANOVA (n = 10) (α = 0.05). RESULTS Before polishing, Ra varied significantly among the materials. SM-GC and SM-PM had the lowest and AM-ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM-DT, AM-ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM-ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM-DT had higher Ra than SM-PM when distilled water (P = 0.040) and higher Ra than SM-GC, SM-PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM-DT, AM-ND, and CV. For AM-DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM-ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.034). When NaOCl was used, AM-ND had higher ΔE00 than SM-GC, SM-PM, and AM-DT, while CV and SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.039). Finally, when the tablet was used, AM-ND and CV had the highest ΔE00 , while AM-DT had lower ΔE00 than SM-GC (P ≤ 0.015). CONCLUSIONS The tested materials had unacceptable surface roughness (>0.2 μm) before polishing. Roughness decreased significantly after polishing (<0.2 μm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 μm). Considering previously reported color thresholds, AM-ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM-GC, SM-PM, and AM-DT.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Julia Anouk Hess
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Dönmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey
| | - Deniz Yılmaz
- Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Abdulaziz Alhotan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Anne Peutzfeldt
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| |
Collapse
|
25
|
Curado TFF, Silva JR, Nascimento LN, Leles JLR, McKenna G, Schimmel M, Leles CR. Implant survival/success and peri-implant outcomes of titanium-zirconium mini implants for mandibular overdentures: Results from a 1-year randomized clinical trial. Clin Oral Implants Res 2023; 34:769-782. [PMID: 37254798 DOI: 10.1111/clr.14102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/15/2023] [Accepted: 05/18/2023] [Indexed: 06/01/2023]
Abstract
OBJECTIVE To report the 1-year implant survival/success and peri-implant outcomes of mandibular overdentures retained by four titanium-zirconium mini implants (Straumann® Mini Implant System), and to assess how surgery and loading protocols influence these outcomes. MATERIALS AND METHODS A 2 × 2 factorial randomized clinical trial (RCT) tested the combined effects of two loading protocols (immediate or delayed) and two surgical approaches (flapless or flapped) on the success/survival of the mini implants, and peri-implant parameters (plaque, bleeding, sulcus depth, gingival position, and marginal bone loss). Outcomes were assessed up to 1-year after loading, and generalized estimating equations (GEEs) were used to analyze longitudinal and within-patient clustered data. RESULTS Two hundred and ninety-six implants were placed in 74 patients. The implant survival/success rates after 1 year were 100%, and no major biological complications were observed. After 1-year, descriptive data suggest no noticeable changes in plaque scores, whilst a reduction in bleeding scores at the 6-month and 1-year follow-ups compared to baseline. Good longitudinal stability was observed for the probing depth and gingival margin height measures. Overall mean marginal bone loss was 0.68 (±0.68) mm after 3 months and 0.89 (±0.75) mm after 1-year. The flapless protocol showed better results on soft tissue stability and health but a slightly higher risk for marginal bone loss. CONCLUSION The results of this RCT suggest that mandibular overdentures retained by this novel mini implant system represent a safe and predictable treatment option as confirmed by implant survival/success and peri-implant outcomes, even when flapless surgery and immediate loading protocols are adopted.
Collapse
Affiliation(s)
| | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cláudio Rodrigues Leles
- School of Dentistry, Federal University of Goias, Goiania, Brazil
- Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine of the University of Bern, Bern, Switzerland
| |
Collapse
|
26
|
Çakmak G, Oosterveen-Rüegsegger AL, Akay C, Schimmel M, Yilmaz B, Donmez MB. Influence of polishing technique and coffee thermal cycling on the surface roughness and color stability of additively and subtractively manufactured resins used for definitive restorations. J Prosthodont 2023. [PMID: 37421940 DOI: 10.1111/jopr.13730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/05/2023] [Accepted: 06/25/2023] [Indexed: 07/10/2023] Open
Abstract
PURPOSE To evaluate how different polishing techniques and coffee thermal cycling effect the surface roughness and stainability of additively and subtractively manufactured resins used for definitive prostheses. MATERIALS AND METHODS Two additively manufactured composite resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 90 rectangular-shaped specimens (14 × 12 × 1 mm) (n = 30). After baseline surface roughness (Ra ) measurements, specimens were divided into 3 groups based on the polishing technique; conventional polishing with a 2-stage polishing kit (CP) and surface sealant application (Optiglaze, OG or Vita Akzent LC, VA) (n = 10). After polishing, specimens were subjected to 10000 cycles of coffee thermal cycling. Ra and color coordinate measurements were performed after polishing and after coffee thermal cycling. Color difference (ΔE00 ) was calculated. Scanning electron microscope images were taken at each time interval. Kruskal-Wallis or 1-way analysis of variance (ANOVA) were used to evaluate Ra of materials within each polishing-time interval pair and different polishing techniques within each material-time interval pair, while Friedman or repeated measures ANOVA were used to evaluate Ra at different time intervals within each material-polishing pair. ΔE00 was assessed with 2-way ANOVA (α = .05). RESULTS Other than VA-after polishing (P = .055), tested materials had significantly different Ra within each polishing-time interval pair (P ≤ .038). When Ra differences among different polishing techniques within each material-time interval pair were considered, CS had differences after coffee thermal cycling, CT had differences before polishing and after coffee thermal cycling, and VS had differences within each time interval (P ≤ .038). When Ra differences among different time intervals within each material-polishing pair were considered, significant differences were observed among all pairs (P ≤ .016), except for CS-VA (P = .695) and VS-VA (P = .300). ΔE00 values were affected by material and polishing technique interaction (P = .007). CONCLUSIONS Ra of CS was similar to or lower than the Ra of other materials, regardless of the time interval or polishing technique. CP mostly led to lower Ra than other polishing techniques, whereas VA resulted in a high Ra regardless of the material-time interval pair. Polishing reduced the Ra , while coffee thermal cycling was found to have a small effect. Among tested material-polishing pairs, only CS-VA had moderately unacceptable color change when previously reported threshold values were considered. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Alice Lisa Oosterveen-Rüegsegger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Private Practice, Zahnarzt Praxis Gadzo AG, Interlaken, Switzerland
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| |
Collapse
|
27
|
Chebib N, Holmes E, Maniewicz S, Abou-Ayash S, Srinivasan M, McKenna G, Kossioni A, Schimmel M, Müller F, Brocklehurst P. Exploring preferences of older adults for dental services: A pilot multi-national discrete choice experiment. Gerodontology 2023. [PMID: 37309614 DOI: 10.1111/ger.12696] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/28/2023] [Indexed: 06/14/2023]
Abstract
OBJECTIVES To pilot an exploration of older adults' future preferences using discrete choice experiments to understand who should provide dental examinations and treatment, where these services should be provided, and participants' willingness to pay and willingness to travel. BACKGROUND The proportion of older adults in the general population is increasing and is recognised as a pressing public health challenge. MATERIALS AND METHODS Older people aged 65 years and over were recruited into this study from the UK, Switzerland and Greece. Drawing on earlier stakeholder engagement, a set of choice experiments are developed to explore the future preferences of older people for dental examinations and dental treatment, as they anticipated losing their independence. These were presented to the participants using a range of platforms, because of the COVID pandemic. Data were analysed in STATA using a random-effects logit model. RESULTS Two hundred and forty-six participants (median age 70 years) completed the pilot study. There was a strong preference across all countries for a dentist to undertake a dental examination (Greece: β = 0.944, Switzerland: β = 0.260, UK β = 0.791), rather than a medical doctor (Greece: β = -0.556, Switzerland: β = -0.4690, UK: β = -0.468). Participants in Switzerland and the UK preferred these examinations to be undertaken in a dental practice (Switzerland: β = 0.220, UK: β = 0.580) while participants in Greece preferred the dental examination to be undertaken in their homes (β = 1.172). Greek participants preferred dental treatment to be undertaken by a specialist (β = 0.365) in their home (β = 0.862), while participants from the UK and Switzerland preferred to avoid any dental treatment at home (Switzerland: β = -0.387; UK: β = -0.444). Willingness to pay analyses highlighted that participants in Switzerland and the UK were willing to pay more to ensure the continuity of future service provision at a family dental practice (Switzerland: β = 0.454, UK: β = 0.695). CONCLUSION Discrete choice experiments are valuable for exploring older people's preferences for dental service provision in different countries. Future larger studies should be conducted to further explore the potential of this approach, given the pressing need to design services that are fit for purpose for older people. Continuity of dental service provision is considered as important by most older people, as they anticipate losing their dependence.
Collapse
Affiliation(s)
- Najla Chebib
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Emily Holmes
- Centre for Health Economics and Medicines Evaluation (CHEME), School of Health Sciences, Bangor University, Bangor, UK
| | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Murali Srinivasan
- Clinic of General- Special care- and Geriatric Dentistry, Center of Dental Medicine, University of Zürich, Zürich, Switzerland
| | - Gerald McKenna
- Health Services Research Group, Centre for Public Health, Queens University Belfast, Belfast, UK
| | - Anastasia Kossioni
- Division of Gerodontology, Department of Prosthodontics, Dental School of the National and Kapodistrian University of Athens, Athens, Greece
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Centre for Health Economics and Medicines Evaluation (CHEME), School of Health Sciences, Bangor University, Bangor, UK
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | | |
Collapse
|
28
|
Zaugg FL, Abou-Ayash S, Molinero-Mourelle P, Rizzo-Marques V, Schimmel M, Wittneben JG. Distortion assessment of different materials in full-arch dentate impressions in relation to operator experience: a comparative in vivo. INT J PROSTHODONT 2023. [PMID: 37273186 DOI: 10.11607/ijp.8555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE Evaluating the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience. MATERIAL AND METHODS Twenty-eight students (group A) and 7 dentists (group B) performed 3 maxillary impressions on 28 students (participants), each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized. Intraoral scans were taken as a control. Differences between master casts and intraoral scans were visualized by heatmaps and planar deviations were investigated. If planar deviations of >120 μm were found, the impression was rated as "distorted." An additional superimposition using the casts from VSE or PE was performed to confirm the presence of distortions. The relative number of surfaces with distortions in each impression was calculated. The procedure was repeated for a distortion threshold of 500 μm. The statistical analyses included measures ANOVA and post-hoc tests (a < 0.05). RESULTS When 120 μm was considered as the threshold for distortions, IHC impressions showed higher distortion probability than PE impressions in group A (P = 0.003) and group B (P < 0.0001). In group B only, PE showed a lower distortion probability than VSE (P = 0.02). There was no difference between the study groups (P = 0.42). Considering 500 μm as a threshold for distortions, there was no difference between impression materials (P = 0.17) or study groups (P = 0.53). CONCLUSION There were no statistic significant differences in relation to operator experience. Different impression materials had a significant impact on distortion probability. Polyether impressions showed the lowest distortion probability. Int J Prosthodont. 10.11607/ijp.8555.
Collapse
|
29
|
Anliker N, Molinero-Mourelle P, Weijers M, Bukvic H, Bornstein MM, Schimmel M. Dental status and its correlation with polypharmacy and multimorbidity in a Swiss nursing home population: a cross-sectional study. Clin Oral Investig 2023; 27:3021-3028. [PMID: 36881159 PMCID: PMC10264277 DOI: 10.1007/s00784-023-04906-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 02/03/2023] [Indexed: 03/08/2023]
Abstract
OBJECTIVE To assess the correlation between oral health status in terms of present teeth, implants, removable prostheses, and polypharmacy and/or multimorbidity in three Swiss nursing homes with affiliated or integrated dental care. METHODS A cross-sectional study was conducted in three Swiss geriatric nursing homes with integrated dental care. Dental information consisted of the number of teeth, root remnants, implants, and presence of removable dental prostheses. Furthermore, the medical history was assessed in terms of diagnosed medical conditions and prescribed medication. Age, dental status, polypharmacy, and multimorbidity were compared and correlated using t-tests and Pearson correlation coefficients. RESULTS One hundred eighty patients with a mean age of 85.5 ± 7.4 years were included of which a portion of 62% presented with multimorbidity and 92% with polypharmacy. The mean number of remaining teeth and remnant roots were 14.1 ± 9.9 and 1.0 ± 3.1, respectively. Edentulous individuals comprised 14%, and over 75% of the population did not have implants. Over 50% of the included patients wore removable dental prostheses. A negative correlation with statistical significance (p = 0.001) between age and tooth loss (r = - 0.27) was observed. Finally, there was a non-statistically correlation between a higher number of remnant roots and specific medications linked to salivary dysfunction; specifically antihypertensive medication and central nervous system stimulants. CONCLUSION The presence of a poor oral health status was associated with polypharmacy and multimorbidity among the study population. CLINICAL RELEVANCE Identifying elderly patients in need of oral healthcare in nursing homes is a challenge. In Switzerland, the collaboration of dentists and nursing staff is still improvable, but is urgently needed due to the demographic changes and raising treatment demand of the oldest portion of the population.
Collapse
Affiliation(s)
- Noemi Anliker
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland
| | - Mariëtte Weijers
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland
| | - Hristina Bukvic
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland
| | - Michael M Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland.
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
| |
Collapse
|
30
|
Schimmel M, Anliker N, Sabatini GP, De Paula MS, Weber AR, Molinero-Mourelle P. Assessment and Improvement of Masticatory Performance in Frail Older People: A Narrative Review. J Clin Med 2023; 12:jcm12113760. [PMID: 37297955 DOI: 10.3390/jcm12113760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 06/12/2023] Open
Abstract
According to the World Health Organization (WHO), the estimated number of older adults is around 962 million and is projected to increase to 2.1 billion by 2050. The oral frailty concept is associated with gradual oral function loss in relation to aging. There is a need to emphasize the improvement of oral function based on an evaluation of masticatory performance in patients with various oral conditions or systemic diseases and especially in the frail elderly. The present narrative review presents an overview of the current state of the assessment and improvement of masticatory performance in frail older people. To fully encompass oral frailty, oro-facial hypofunction, or oro-facial fitness, dental Patient Reported Outcomes (dPROs) should be included; nevertheless, there are limited evidence-based rehabilitation approaches. The concept of oral frailty, oro-facial hypofunction, or oro-facial fitness should involve dental Patient Reported Outcomes (dPROs), and in this sense, there are only a few evidence-based rehabilitation procedures to improve oro-facial hypofunction besides prosthodontics. It must be considered that reduced neuroplastic capacity in old individuals might preclude a positive outcome of these strategies that might need to be accompanied by functional training and nutritional counseling.
Collapse
Affiliation(s)
- Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, 1211 Geneva, Switzerland
| | - Noemi Anliker
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Gabriela Panca Sabatini
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Prosthodontics, University of São Paulo (USP), São Paulo 05508-900, Brazil
| | - Marcella Silva De Paula
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Prevention and Oral Rehabilitation, Universidade Federal de Goiás, Goiania 74690-900, Brazil
| | - Adrian Roman Weber
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| |
Collapse
|
31
|
Çakmak G, Jutzi D, Donmez MB, Kahveci Ç, de Paula MS, Schimmel M, Yilmaz B. Effect of number of supports and build angle on the fabrication and internal fit accuracy of additively manufactured definitive resin-ceramic hybrid crowns. J Dent 2023; 134:104548. [PMID: 37192693 DOI: 10.1016/j.jdent.2023.104548] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 04/03/2023] [Accepted: 05/12/2023] [Indexed: 05/18/2023] Open
Abstract
OBJECTIVES To evaluate the effect of number of supports and build angle on the fabrication and internal fit accuracy (trueness and precision) of additively manufactured resin-ceramic hybrid crowns. METHODS A mandibular first molar crown was designed and nested on the build platform of a printer either with a 30° angle between the occlusal surface and the build platform (BLS (less support) and BMS (more support)) or its occlusal surface parallel to the build platform (VLS (less support) and VMS (more support)) to fabricate additively manufactured resin-ceramic hybrid crowns (n=14). After fabrication, supports were removed by a blinded operator and all crowns were digitized with an intraoral scanner. Fabrication accuracy (overall, external, intaglio occlusal, occlusal, and marginal) was evaluated by using root mean square (RMS) method, while internal fit was evaluated with triple scan method. RMS, average gap, and precision of these data were analyzed (α= .05). RESULTS VLS had higher overall deviations than BLS and VMS (P≤.039). VMS had higher occlusal deviations than BLS (P=.033). While BMS and BLS had higher marginal deviations than VLS (P≤.006), BMS also had higher values than VMS (P=.012). BLS led to higher precision than VMS (intaglio occlusal and occlusal surfaces) and VLS (occlusal surface) (P≤.008). VLS led to higher precision than BMS (marginal surface) (P=.027). Average gap values were similar (P=.723); however, BLS resulted in higher precision than VLS (P=.018). CONCLUSIONS Considering their high marginal and occlusal surface trueness, and similar internal occlusal deviations and average gaps (trueness), clinical fit of resin-ceramic hybrid crowns fabricated with tested parameters may be similar. Reduced number of supports and angled orientation may lead to higher precision of fit. CLINICAL SIGNIFICANCE Tested resin-ceramic hybrid-printer pair may be used to fabricate crowns with reduced number of supports to maintain occlusal surface integrity without compromising the fabrication accuracy and fit.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Dino Jutzi
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Istinye University, Faculty of Dentistry, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Çiğdem Kahveci
- Department of Prosthodontics, Giresun University Faculty of Dentistry, Giresun, Turkey
| | - Marcella Silve de Paula
- Universidade Federal de Goiás (UFG), Department of Prevention and Oral Rehabilitation, Goiânia, Brazil
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Ohio, USA
| |
Collapse
|
32
|
Donmez MB, Çakmak G, Yılmaz D, Schimmel M, Abou-Ayash S, Yilmaz B, Peutzfeldt A. Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements. J Prosthet Dent 2023:S0022-3913(23)00255-X. [PMID: 37183123 DOI: 10.1016/j.prosdent.2023.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 04/06/2023] [Accepted: 04/06/2023] [Indexed: 05/16/2023]
Abstract
STATEMENT OF PROBLEM Additively manufactured composite resins for definitive restorations have been recently introduced. The bond strength between these composite resins and different substrates has not been extensively studied. PURPOSE The purpose of this in vitro study was to measure the shear bond strength (SBS) between additively manufactured composite resins and dentin and titanium substrates and compare those with the SBS between subtractively manufactured polymer-infiltrated ceramic and the same substrates (dentin and titanium), when different dual-polymerizing resin cements were used. MATERIAL AND METHODS One hundred and eighty cylinder-shaped specimens (Ø5×5 mm) were prepared from 3 materials recommended for definitive restorations: an additively manufactured composite resin (Crowntec [CT]); an additively manufactured hybrid composite resin (VarseoSmile Crown Plus [VS]); and a subtractively manufactured polymer-infiltrated ceramic (Enamic [EN]) (n=60). Specimens were randomly divided into six subgroups to be cemented to the two substrates (dentin and titanium; n=30) with 1 of 3 resin cements (RelyX Universal, Panavia V5, and Variolink Esthetic DC) (n=10). The restoration surface to be bonded was treated according to the respective manufacturer's recommendations. Dentin surfaces were treated according to the resin cement (Scotchbond Universal Plus Adhesive for RelyX Universal, Panavia V5 Tooth Primer for Panavia V5, and Adhese Universal for Variolink Esthetic DC), while titanium surfaces were airborne-particle abraded, and only the specimens paired with Panavia V5 were treated with a ceramic primer (Clearfil Ceramic Primer Plus). SBS was measured in a universal testing machine at a crosshead speed of 1 mm/min. Failure modes were analyzed under a microscope at ×12 magnification. Data were analyzed by using 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS When SBS to dentin was considered, only restorative material, as a main factor, had a significant effect (P<.001); EN had the highest SBS (P<.001), while the difference in SBS values of CT and VS was not significant (P=.145). As for SBS to titanium, the factors restorative material and resin cement and their interaction had a significant effect (P<.001). Within each resin cement, EN had the highest SBS to titanium (P<.001), and within each restorative material, Variolink resulted in the lowest SBS (P≤.010). Overall, EN and RelyX were associated with the highest SBS to titanium (P≤.013). Mixed failures were predominant in most groups. CONCLUSIONS Regardless of the substrate or the resin cement used, the subtractively manufactured polymer-infiltrated ceramic had higher shear bond strength than the additively manufactured composite resins. The SBS of the additively manufactured composite resins, whether bonded to dentin or titanium, were not significantly different from each other. Regardless of the restorative material, Variolink DC resulted in the lowest SBS for titanium surfaces.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Gülce Çakmak
- Senior Resarch Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Deniz Yılmaz
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Anne Peutzfeldt
- Senior Researcher, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Affiliate Professor, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
33
|
Irving JCE, Lekić V, Durán C, Drilleau M, Kim D, Rivoldini A, Khan A, Samuel H, Antonangeli D, Banerdt WB, Beghein C, Bozdağ E, Ceylan S, Charalambous C, Clinton J, Davis P, Garcia R, Horleston AC, Huang Q, Hurst KJ, Kawamura T, King SD, Knapmeyer M, Li J, Lognonné P, Maguire R, Panning MP, Plesa AC, Schimmel M, Schmerr NC, Stähler SC, Stutzmann E, Xu Z. First observations of core-transiting seismic phases on Mars. Proc Natl Acad Sci U S A 2023; 120:e2217090120. [PMID: 37094138 PMCID: PMC10161042 DOI: 10.1073/pnas.2217090120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023] Open
Abstract
We present the first observations of seismic waves propagating through the core of Mars. These observations, made using seismic data collected by the InSight geophysical mission, have allowed us to construct the first seismically constrained models for the elastic properties of Mars' core. We observe core-transiting seismic phase SKS from two farside seismic events detected on Mars and measure the travel times of SKS relative to mantle traversing body waves. SKS travels through the core as a compressional wave, providing information about bulk modulus and density. We perform probabilistic inversions using the core-sensitive relative travel times together with gross geophysical data and travel times from other, more proximal, seismic events to seek the equation of state parameters that best describe the liquid iron-alloy core. Our inversions provide constraints on the velocities in Mars' core and are used to develop the first seismically based estimates of its composition. We show that models informed by our SKS data favor a somewhat smaller (median core radius = 1,780 to 1,810 km) and denser (core density = 6.2 to 6.3 g/cm3) core compared to previous estimates, with a P-wave velocity of 4.9 to 5.0 km/s at the core-mantle boundary, with the composition and structure of the mantle as a dominant source of uncertainty. We infer from our models that Mars' core contains a median of 20 to 22 wt% light alloying elements when we consider sulfur, oxygen, carbon, and hydrogen. These data can be used to inform models of planetary accretion, composition, and evolution.
Collapse
Affiliation(s)
- Jessica C E Irving
- School of Earth Sciences, University of Bristol, Bristol BS8 1RJ, United Kingdom
| | - Vedran Lekić
- Department of Geology, University of Maryland, College Park 20742
| | - Cecilia Durán
- Institute of Geophysics, ETH Zurich, Zurich 8092, Switzerland
| | - Mélanie Drilleau
- Institut Supérieur de l'Aéronautique et de l'Espace ISAE-SUPAERO, Toulouse 31055, France
| | - Doyeon Kim
- Institute of Geophysics, ETH Zurich, Zurich 8092, Switzerland
| | | | - Amir Khan
- Institute of Geophysics, ETH Zurich, Zurich 8092, Switzerland
- Institute of Geochemistry and Petrology, ETH Zurich, Zurich 8092, Switzerland
| | - Henri Samuel
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris 75005, France
| | - Daniele Antonangeli
- Sorbonne Université, Muséum National d'Histoire Naturelle, UMR CNRS 7590, Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, Paris 75005, France
| | | | - Caroline Beghein
- Department of Earth, Planetary, and Space Sciences, University of California, Los Angeles, CA 90095
| | - Ebru Bozdağ
- Department of Applied Mathematics and Statistics & Department of Geophysics, Colorado School of Mines, Golden, CO 80401
- Department of Geophysics, Colorado School of Mines, Golden, CO 80401
| | - Savas Ceylan
- Institute of Geophysics, ETH Zurich, Zurich 8092, Switzerland
| | - Constantinos Charalambous
- Department of Electrical and Electronic Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - John Clinton
- Swiss Seismological Service, ETH Zurich, Zurich 8092, Switzerland
| | - Paul Davis
- Department of Earth, Planetary, and Space Sciences, University of California, Los Angeles, CA 90095
| | - Raphaël Garcia
- Institut Supérieur de l'Aéronautique et de l'Espace ISAE-SUPAERO, Toulouse 31055, France
| | | | - Quancheng Huang
- Department of Geophysics, Colorado School of Mines, Golden, CO 80401
| | - Kenneth J Hurst
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
| | - Taichi Kawamura
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris 75005, France
| | - Scott D King
- Department of Geosciences, Virginia Tech, Blacksburg, VA 24061
| | | | - Jiaqi Li
- Department of Earth, Planetary, and Space Sciences, University of California, Los Angeles, CA 90095
| | - Philippe Lognonné
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris 75005, France
| | - Ross Maguire
- Department of Geology, University of Illinois Urbana-Champaign, Urbana, IL 61801
| | - Mark P Panning
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
| | | | | | | | - Simon C Stähler
- Institute of Geophysics, ETH Zurich, Zurich 8092, Switzerland
- Physik-Institut, Universität Zürich, Zurich 8057, Switzerland
| | - Eleonore Stutzmann
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris 75005, France
| | - Zongbo Xu
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris 75005, France
| |
Collapse
|
34
|
Eichelkraut D, Meissner F, Wetzel M, Schimmel M, Czerny M, Bothe W. Impact of a Novel Left Ventricular Assist Device Adapter with Transvalvular Aortic Outflow on the Device Flow Rate In Vitro. J Heart Lung Transplant 2023. [DOI: 10.1016/j.healun.2023.02.1069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
|
35
|
Roccuzzo A, Borg-Bartolo R, Schimmel M, Tennert C, Manton DJ, Campus G. Evaluation of the Oral Health Conditions and Oral Health-Related Quality of Life in a Community-Dwellers Population Aged ≥ 45 Years in the Canton of Bern: A Preliminary Pilot Study. Int J Environ Res Public Health 2023; 20:4557. [PMID: 36901566 PMCID: PMC10001686 DOI: 10.3390/ijerph20054557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVE To evaluate oral health conditions and oral health-related quality of life in community-dwellers aged ≥ 45 years in the Canton of Bern, Switzerland. MATERIALS AND METHODS One hundred subjects (63% males; mean age: 73 years), selected randomly using a cluster procedure within the Canton of Bern, underwent a clinical oral examination after completing questionnaires on socio-economic level, medical history, oral health behaviour, and Geriatric Oral Health Assessment Index (GOHAI). Descriptive analyses and multinomial regression models were applied to investigate the association between oral health diseases (dental caries and periodontitis) and specific participant characteristics. RESULTS The mean number of decayed, missing, and filled teeth (DMFT) was 0.30, 4.20, and 8.75, respectively; the mean DMFT score = 13.35. Dental caries prevalence (ICDAS > 0) was 15% and periodontitis prevalence was 46%. Logistic regression models revealed that living in an urban area was associated with lower odds (OR 0.03, 95%CI 0.00-0.36) of having periodontal disease. Male gender was associated with lower odds for dental caries (OR 0.31, 95%CI 0.09-1.01) and total lack of professional tooth cleaning was associated with higher odds for dental caries (OR 41.99, 95%CI 0.01-0.38). Ordinal logistic regression revealed that both the presence of dental caries (RR 12.80, 95%CI 1.47-111.20) and periodontal disease (RR 6.91, 95%CI 1.16-84.00) were statistically significantly associated with rheumatoid arthritis. CONCLUSION Within the study limitations, untreated dental caries and periodontal disease are prevalent in the Swiss population, despite the high level of self-performed oral hygiene and access to the dental care system.
Collapse
Affiliation(s)
- Andrea Roccuzzo
- Department of Restorative, Pediatric and Preventive Dentistry, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Periodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Roberta Borg-Bartolo
- Department of Restorative, Pediatric and Preventive Dentistry, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, 1205 Geneva, Switzerland
| | - Christian Tennert
- Department of Restorative, Pediatric and Preventive Dentistry, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
| | - David J. Manton
- Centre for Dentistry and Oral Health, University Medical Centre Groningen, 9713 AV Groningen, The Netherlands
| | - Guglielmo Campus
- Department of Restorative, Pediatric and Preventive Dentistry, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Surgery, Microsurgery and Medicine Sciences, School of Dentistry, University of Sassari, 07100 Sassari, Italy
| |
Collapse
|
36
|
Roccuzzo A, Fanti R, Mancini L, Imber JC, Stähli A, Molinero-Mourelle P, Schimmel M, Sculean A, Salvi GE. Implant-supported fixed dental prostheses with cantilever extensions: State of the art and future perspectives. Int J Oral Implantol (Berl) 2023; 16:13-28. [PMID: 36861678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
Partial fixed dental prostheses supported by dental implants have become a reliable long-term treatment option. Nevertheless, the replacement of two adjacent missing teeth, irrespective of location, still represents a clinical challenge. To overcome this, the use of fixed dental prostheses with cantilever extensions has gained popularity with a view to limiting morbidity, reducing costs and avoiding major surgical interventions prior to implant placement. The present review summarises the level of evidence for the use of fixed dental prostheses with cantilever extensions both in the posterior and anterior regions and indicates the advantages and disadvantages of each treatment, focusing on available medium- to long-term outcomes.
Collapse
|
37
|
Donmez MB, Yilmaz B, Yoon HI, Kahveci Ç, Schimmel M, Çakmak G. Effect of computer-aided design and computer-aided manufacturing technique on the accuracy of fixed partial denture patterns used for casting or pressing. J Dent 2023; 130:104434. [PMID: 36693586 DOI: 10.1016/j.jdent.2023.104434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 01/16/2023] [Accepted: 01/20/2023] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES To evaluate the effect of additive and subtractive manufacturing on the accuracy (trueness and precision) of fixed partial denture patterns (FPDPs) used for casting or pressing. MATERIALS AND METHODS A 3-unit complete coverage FPD on mandibular right first premolar and first molar teeth was virtually designed. Using the design data, FPD patterns were fabricated from an additively manufactured resin (PR, ProArt Print Wax) and 2 CAD-CAM wax discs (YW, ProArt CAD Wax Yellow and BW, ProArt CAD Wax Blue) (n = 10). Each pattern was then digitized with a scanner (CEREC Primescan) and evaluated for 3D surface deviation at 4 different surfaces (overall, external, marginal, and intaglio surfaces) by using a 3D analysis software (Medit Link). Root mean square (RMS) values were automatically calculated. Data were analyzed by using Kruskal-Wallis and Dunn's post hoc tests for trueness and precision (α= 0.05). RESULTS Significant differences were found among the RMS values for overall (P<.001) and each surface (P≤.040) evaluated. PR had the highest overall (P≤.011) and intaglio surface (P≤.01) deviations, while the difference between YW and BW was not significant (P≥.199). PR had the highest (P≤.027) and BW had the lowest (P≤.042) external surface mean RMS values. BW had higher mean marginal RMS value than YW (P=.047). For precision, significant differences were observed among test groups only for marginal RMS values (P=.002). PR had lower precision than BW (P=.002). CONCLUSIONS BW and YW FPDPs mostly had higher trueness compared with PR FPDPs. However, considering relatively smaller deviations at marginal and intaglio surfaces and the fact that patterns mostly had similar precision, clinical fit of FPDs fabricated by using tested patterns may be similar. CLINICAL SIGNIFICANCE Definitive 3-unit fixed partial dentures fabricated by using tested patterns may be similar. However, FPDs fabricated with tested additively manufactured resin patterns might result in more chairside adjustments than those fabricated with tested subtractively manufactured wax patterns.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Ohio, USA
| | - Hyung-In Yoon
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, South Korea
| | - Çiğdem Kahveci
- Department of Prosthodontics, Faculty of Dentistry, Giresun University, Giresun, Turkey
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
38
|
Çakmak G, Herren KV, Donmez MB, Kahveci Ç, Schimmel M, Yilmaz B. Effect of coffee thermocycling on the surface roughness and stainability of nanographene-reinforced polymethyl methacrylate used for fixed definitive prostheses. J Prosthet Dent 2023; 129:507.e1-507.e6. [PMID: 36737355 DOI: 10.1016/j.prosdent.2022.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM A nanographene-reinforced polymethyl methacrylate (PMMA) has been introduced for definitive prostheses. However, knowledge on the surface roughness and stainability of this material is lacking. PURPOSE The purpose of this in vitro study was to compare the surface roughness and stainability of nanographene-reinforced PMMA with those of a prepolymerized PMMA and a reinforced composite resin after coffee thermocycling. MATERIAL AND METHODS Disk-shaped specimens (Ø10×1.5-mm) were prepared from 3 different A1-shade millable resins (prepolymerized PMMA [M-PM; PMMA]; nanographene-reinforced PMMA [G-CAM; G-PMMA]; reinforced composite resin [Brilliant Crios; RCR]). Surface roughness (Ra) values were measured before and after conventional polishing by using a noncontact profilometer. Initial color coordinates were measured over a gray background with a spectrophotometer after polishing. Specimens were then thermocycled in coffee for 5000 cycles. Measurements were repeated after coffee thermocycling, and color differences (ΔE00) were calculated. Ra values among different time intervals were analyzed by using either the Friedman and Dunn tests (RCR) or repeated measures analysis of variance (ANOVA) and Bonferroni corrected paired samples t tests (PMMA and G-PMMA), while Ra values within a time interval were analyzed by using either the Kruskal-Wallis and Dunn tests (before polishing) or 1-way ANOVA and Tukey HSD (after polishing) or Tamhane T2 tests (after coffee thermocycling). ΔE00 values were analyzed by using 1-way ANOVA and Tukey HSD tests, while color coordinates of the specimens after polishing and after coffee thermocycling were compared by using paired samples t tests (α=.05). RESULTS All materials had their highest Ra values before polishing (P≤.011), while differences after polishing and after coffee thermocycling values were nonsignificant (P≥.140). PMMA had higher Ra than RCR before polishing (P=.002), and RCR had higher values than G-PMMA after polishing and after coffee thermocycling (P≤.023). RCR had the highest ΔE00 (P<.001). Polishing increased the b∗ values of PMMA, and coffee thermocycling increased the a∗ values of G-PMMA and all values of RCR (P≤.012). CONCLUSIONS The tested materials had similar and acceptable surface roughness after polishing. The surface roughness of materials was not affected by coffee thermocycling. Considering the reported color thresholds, all materials had acceptable color change, but the computer-aided design and computer-aided manufacturing composite resin had perceptible color change after coffee thermocycling.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Kira Vera Herren
- Predoctoral student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Private Practice, Zahnaerzte Flamatt, Wünnewil-Flamatt, Switzerland
| | - Mustafa Borga Donmez
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Çiğdem Kahveci
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Giresun University, Giresun, Turkey
| | - Martin Schimmel
- Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
39
|
Leles CR, Nascimento LN, Silva JR, de Paula MS, Curado TFF, McKenna G, Schimmel M. Willingness to accept or refuse mandibular implant overdenture treatment: A prospective study on edentulous enrolled in a clinical trial. J Oral Rehabil 2023; 50:392-399. [PMID: 36789570 DOI: 10.1111/joor.13429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/26/2022] [Accepted: 02/06/2023] [Indexed: 02/16/2023]
Abstract
BACKGROUND Several complete denture wearers have major complaints and may be benefitted from implant treatment. However, the factors that shape the demand for and utilization of implants need further investigation. OBJECTIVE The aim was to evaluate edentulous patient's willingness to accept or refuse the offer and provision of implant-retained treatment. METHODS As part of a clinical trial, edentulous subjects were offered a mandibular overdenture retained by four mini-implants opposing a conventional maxillary denture. Treatment was offered without any financial costs for the patients. Patients' level of interest in receiving treatment was assessed using a 5-point Likert scale, and they were asked to respond to a list of reasons that led to their decision to accept or refuse implants. Those who refused implants received conventional prosthodontic interventions as required, and those who accepted implant treatment underwent surgical planning and implant placement. RESULTS Of 175 eligible subjects, 147 accepted the offer of treatment and were invited to take part in the study (69.4% women, mean age 67.4 ± 10.0 years). Overall, 111 patients (75.5%) expressed a positive intention to undergo implant treatment at the initial contact. Implant treatment was performed for 56.3% (9/16) of those who answered 'probably yes' about their level of interest in implant treatment on the Likert scale, and 69.6% (64/92) of 'certainly yes' (p < .001). Older subjects were less likely to receive implants (OR = 0.93; p = .036), whilst those with a positive intention towards implants (OR = 3.15; p = .001), those previously treated by the dental team (OR = 7.89; p < .001), and who actively demanded implants (OR = 18.1; p < .001) were more likely to accept treatment. Improved chewing was the most common reason for accepting implants, whilst fear of surgery was the most reported reason for refusal. CONCLUSION Refusal of implants was high among edentate patients even when financial costs were removed. Patients' initial attitude towards acceptance is a key factor in the demand for and uptake of implant therapy.
Collapse
Affiliation(s)
| | | | | | | | | | - Gerald McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
40
|
Igarashi K, Katagiri H, Abou-Ayash S, Schimmel M, Afrashtehfar KI. Double-Crown Prosthesis Retention Using Polyetherketoneketone (PEKK): An In Vitro Study. J Prosthodont 2023; 32:154-161. [PMID: 35343624 DOI: 10.1111/jopr.13512] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/23/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To assess the retentive force of telescopic crowns using polyetherketoneketone (PEKK) high-performance polymer in relation to conventional materials over a long period of time in an in vitro setting. MATERIALS AND METHODS Thirty-six sets of primary and secondary crowns were fabricated as per the double crown-retained prostheses approach. Six samples were included in each of the five test groups (1: zirconia/PEKK [Zr/PEKK]; 2: titanium/PEKK [Ti/PEKK]; 3: cobalt-chrome/PEKK [CoCr/PEKK]; 4: PEKK/PEKK; and 5: gold/PEKK [Au/PEKK]) and the single control group (gold/galvano-gold [Au/GA]). The insertion-removal test was performed for 20,000 cycles, and the surface condition was observed. Retentive forces were analyzed using two-way ANOVA (α<0.05). RESULTS The retention forces in groups Zr/PEKK and Ti/PEKK significantly decreased over time (group 1: p = 0.035 and group 2: p = 0.001), whereas retentive force increased significantly in groups PEKK/PEKK, Au/PEKK, and control (group 4: p = 0.001, group 5: p = 0.008, and control: p = 0.042). Similar wear was observed on the primary crown in groups PEKK/PEKK, gold/PEKK, and control. CONCLUSIONS Groups PEKK/PEKK and Au/PEKK showed a transition of retentive force similar to the control group. Groups PEKK/PEKK and Au/PEKK had similar wear on the surface compared to control. Therefore, PEKK has a promising clinical potential.
Collapse
Affiliation(s)
- Kensuke Igarashi
- Department of Dental Materials Science, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan
| | - Hiroki Katagiri
- Advanced Research Center, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan.,Department of Histology, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Kelvin I Afrashtehfar
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Clinical Sciences Department, Ajman University College of Dentistry, Ajman Emirate, UAE.,School of Biomedical and Health Sciences, Universidad Europea de Madrid, Madrid, Spain
| |
Collapse
|
41
|
Imamura Y, Chebib N, Ohta M, Mojon P, Schulte-Eickhoff RM, Schimmel M, Graf C, Sato Y, Müller F. Masticatory performance in oral function assessment: Alternative methods. J Oral Rehabil 2023; 50:383-391. [PMID: 36691751 DOI: 10.1111/joor.13421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 11/21/2022] [Accepted: 01/13/2023] [Indexed: 01/25/2023]
Abstract
BACKGROUND Masticatory function declines with age or disease, implicating a poor chewing efficiency and an often-unconscious change for a less healthy, yet easy to chew diet. Timely screening of masticatory function may foster an early-onset diagnosis and potential treatment. The aim of this study was to compare alternative diagnostic tools for masticatory function to a Jelly-scan test. MATERIALS AND METHODS Patients aged 70 years and older who were hospitalised for rehabilitation were recruited for this study. A total of four different tests for masticatory function were administered. The Japanese Society of Gerodontology glucose extraction test (Jelly-scan) was used as reference to compare a colour-changing gum test (Gum1-colour) as well as a mixing ability test with a visual (Gum2-visual) and opto-electronical (Gum2-digital) analyses. Receiver operating characteristic (ROC) curves were used to establish the discriminative value, kappa-values were used to estimate individual agreements and correlations were verified using Spearman's tests. RESULTS Sixty-one patients (Men n = 23, Women n = 38) aged 82.4 ± 6.8 years participated in the experiments. The average number of natural teeth was 16.5 ± 10.5, 34.4% of the participants wore removable dentures. For all tests, the sum of sensitivity and specificity was >150%. All test correlated with Jelly-scan (absolute Rho >0.5). With Jelly-scan 51 participants (83.6%) were diagnosed with "masticatory hypofunction". After reducing the cut-off value of the test from 100 mg/dL to 65 mg/dL, only 33 participants (54%) fulfilled the diagnosis. This post-hoc analysis increased the sensitivity of the Gum2-tests and the agreement to kappa >0.5 for all three tests. CONCLUSION All three tests can be considered useful screening alternatives. In its original version, Jelly-scan may tend to over-diagnose masticatory hypofunction, hence a novel cut-off with better agreement between tests is suggested.
Collapse
Affiliation(s)
- Yoshiki Imamura
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Geriatric Dentistry, School of Dentistry, Showa University, Tokyo, Japan.,Department of Prosthodontics, Meikai University School of Dentistry, Tokyo, Japan
| | - Najla Chebib
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Midori Ohta
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Removable Prosthodontics & Gerodontology, Tokyo Dental College, Tokyo, Japan
| | - Philippe Mojon
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | | | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Christophe Graf
- Department of Rehabilitation and Geriatrics, University Hospitals Geneva, Geneva, Switzerland
| | - Yuji Sato
- Department of Geriatric Dentistry, School of Dentistry, Showa University, Tokyo, Japan
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Rehabilitation and Geriatrics, University Hospitals Geneva, Geneva, Switzerland
| |
Collapse
|
42
|
Leles CR, Leles JLR, Curado TFF, Silva JR, Nascimento LN, de Paula MS, Maniewicz S, Schimmel M, McKenna G. Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium-zirconium mini-implants for overdentures: A cross-sectional analysis. Clin Implant Dent Relat Res 2023; 25:426-434. [PMID: 36623506 DOI: 10.1111/cid.13181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 12/29/2022] [Accepted: 01/01/2023] [Indexed: 01/11/2023]
Abstract
OBJECTIVE The aim of this study was to assess the final insertion torque values achieved using site-specific drilling protocols for a novel mini implant system for removable complete overdentures. Anatomical and technical factors influencing final insertion torque were recorded and analyzed. MATERIAL AND METHODS Participants were randomized to two surgical protocol groups (flapped or flapless) and all received four mini implants (Straumann® mini implant system; Straumann AG) in the anterior mandible, using a 1.6 mm needle drill and a 2.2 mm pilot drill for the implant bed site preparation. The final insertion torque was recorded as the main outcome variable during surgery. Bone type, radiographical bone density, ridge form, implant length, and the drilling protocol were considered as independent variables. Descriptive statistics, generalized estimating equations (GEE) regression, and heatmap charts were used for data analyses. RESULTS A total of 296 mini implants were placed in 74 patients (mean age = 64.1 ± 8.0; 64.9% female) using flapless (n = 37) or flapped (n = 37) surgeries. Mean final insertion torque was 55.8 ± 18.4 Ncm (10.5% > 35 Ncm, 48.9% between 35 and 65 Ncm, and 40.6% > 65 Ncm). The needle drill was used in only 43.9% of the implant bed sites. Higher final torque values were observed for higher bone densities (bone type I > II > III, and D1-D2 > D3-D4), highly resorbed ridge forms (5-6 > 3-4), flapped surgeries, and male patients. However, regression models showed that the likelihood of achieving optimal insertion torque (≥35 and ≤65 Ncm) was higher for females (OR = 2.14; 95%CI = 1.14-4.01; p = 0.018), ridge forms 3-4 (OR = 2.87; 95%CI = 1.05-7.85; p = 0.040), and flapless surgeries (OR = 1.96; 95%CI = 1.09-3.51; p = 0.024). CONCLUSIONS Sufficient primary stability for immediate loading was achieved for the majority of the mini implants placed. Surgical implant bed preparation should be site-specific to achieve optimal primary stability for immediate loading while avoiding excessive insertion torque.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gerald McKenna
- Consultant in Restorative Dentistry, Centre for Public Health, Queen's University Belfast, Belfast, UK
| |
Collapse
|
43
|
Abou-Ayash S, Schimmel M, Worni A, Enkling N. O-Ring Attachments on One-Piece Mini Dental Implants: In Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations. INT J PROSTHODONT 2023; 36:59–62. [PMID: 33625384 DOI: 10.11607/ijp.7055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To analyze the influence of pristine matrix and O-ring dimensions on retention force and reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions. MATERIALS AND METHODS Three different matrix and O-ring combinations (MH1-MH3) were evaluated (n = 50 per group) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and were subsequently removed in a vertical linear manner using a metal pin with two strain gauges, recording the maximum force during disconnection. After five disconnections, the O-rings were exchanged, and the mean retention force was calculated, resulting in 50 values for each matrix and O-ring combination. Mean retention forces, SDs, and 95% CI were calculated. Analysis of variance was used to test the global differences, and post hoc pairwise comparisons were subsequently applied. The level of significance was set to P < .05. RESULTS ANOVA (global P < .0001) and pairwise comparisons (all P < .0001) demonstrated statistically significant differences among the three different matrix and O-ring combinations, with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished. CONCLUSION Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices.
Collapse
|
44
|
Srimurugan-Thayanithi N, Abou-Ayash S, Yilmaz B, Schimmel M, Brägger U. Effect of Abutment Cooling on Reverse Torque Values of Abutment Screws: An In Vitro Study. Int J Oral Maxillofac Implants 2023; 38:94-100. [PMID: 37099583 DOI: 10.11607/jomi.9499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/27/2023] Open
Abstract
Purpose: To evaluate the effect of cooling on the reverse torque values of different abutments in bone-level and tissue-level implants. The null hypothesis was that there would be no difference in reverse torque values of abutment screws when cooled and uncooled implant abutments were compared. Materials and Methods: Bone-level and tissue-level implants (Straumann, each n = 36) were placed in synthetic bone blocks and subdivided into three groups (each n = 12) based on the abutment type (titanium base, cementable abutment, abutment for screw-retained restorations). All abutment screws were tightened to 35 Ncm torque. In half of the implants, a dry ice rod was applied on the abutments close to the implant-abutment connection for 60 seconds before untightening the abutment screw. The remaining implant-abutment pairs were not cooled. The maximum reverse torque values were recorded using a digital torque meter. The tightening and untightening procedure was repeated three times for each implant including cooling for the test groups, resulting in 18 reverse torque values per group. Two-way analysis of variance (ANOVA) was used to analyze the effect of cooling and abutment type on the measurements. Post hoc t tests were used to make group comparisons (α = .05). The P values of post hoc tests were corrected for multiple testing using the Bonferroni-Holm method. Results: The null hypothesis was rejected. Cooling and abutment type significantly affected the reverse torque values in bone-level implants (P = .004) but not in tissue-level implants (P = .051). The reverse torque values of bone-level implants significantly decreased after cooling (20.31 ± 2.55 Ncm vs 17.61 ± 2.49 Ncm). Overall mean reverse torque values were significantly higher in bone-level implants compared to tissue-level implants (18.96 ± 2.84 Ncm vs 16.13 ± 3.17 Ncm; P < .001). Conclusion: Cooling of the implant abutment led to a significant decrease in reverse torque values in bone-level implants and may therefore be recommended as a pretreatment before the application of procedures to remove a stuck implant part.
Collapse
|
45
|
Çakmak G, Rusa AM, Donmez MB, Akay C, Kahveci Ç, Schimmel M, Yilmaz B. Trueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materials. J Prosthet Dent 2022:S0022-3913(22)00690-4. [PMID: 36470758 DOI: 10.1016/j.prosdent.2022.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/31/2022] [Accepted: 10/31/2022] [Indexed: 12/03/2022]
Abstract
STATEMENT OF PROBLEM Advancements in digital dental technologies have enabled the use of different resin-based materials that can be fabricated either additively or subtractively. However, knowledge on the fabrication trueness of these materials is scarce. PURPOSE The purpose of this in vitro study was to investigate the trueness of crowns fabricated by using different resin-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials. MATERIAL AND METHODS A complete crown for a mandibular right first molar with a 30-μm cement space was designed in standard tessellation language (STL) format. This master STL (MC-STL) was used to fabricate 40 complete crowns with 4 different resin-based CAD-CAM materials and either additive (Crowntec [MS]) or subtractive techniques (Brilliant Crios [BC], breCAM.monoCOM [PMMA], and G-CAM [GR]; n=10). All crowns were digitized with an intraoral scanner (CEREC Primescan SW 5.2) to generate their STL files (TC-STLs). MC-STL and TC-STLs were transferred into a 3-dimensional analysis software program (Medit Link v2.4.4), and a trueness (overall, external, occlusal, intaglio occlusal, and marginal) analysis was performed by using the root mean square (RMS) method. The Kruskal-Wallis and Dunn tests were performed to analyze data (α=.05). RESULTS The test groups had significantly different deviations on all surfaces (P≤.001). MS crowns had higher overall (P≤.007) and external surface (P≤.001) deviations than GR and PMMA crowns, while the differences between GR and PMMA crowns were not significant (P≥.441). BC crowns had higher external surface deviations than GR crowns (P=.005), higher occlusal deviations than GR and MS crowns (P≤.007), and higher intaglio occlusal deviations than GR and MS crowns (P≤.009). However, BC crowns had lower marginal deviations than MS and GR crowns (P≤.018). CONCLUSIONS The brand of resin-based CAD-CAM materials affected the trueness of crowns. Additively manufactured crowns (MS) mostly had lower overall and external surface trueness than the other groups. Nevertheless, the deviation values of occlusal, intaglio occlusal, and marginal trueness were generally small; thus, the effect of the tested materials on clinical crown fit may be negligible.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ana Maria Rusa
- Dissertation Student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Asisstant Professor, Department of Prosthodontics, Istinye University, Faculty of Dentistry, İstanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Canan Akay
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey; Associate Professor, Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Çiğdem Kahveci
- Assistant Professor, Department of Prosthodontics, Giresun University Faculty of Dentistry, Giresun, Turkey
| | - Martin Schimmel
- Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| |
Collapse
|
46
|
Borg-Bartolo R, Roccuzzo A, Molinero-Mourelle P, Schimmel M, Gambetta-Tessini K, Chaurasia A, Koca-Ünsal RB, Tennert C, Giacaman R, Campus G. Global prevalence of edentulism and dental caries in middle-aged and elderly persons: A systematic review and meta-analysis. J Dent 2022; 127:104335. [PMID: 36265526 DOI: 10.1016/j.jdent.2022.104335] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/16/2022] [Accepted: 10/14/2022] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVE The aim of the study was to analyze data collected from studies worldwide on the prevalence of edentulism and dental caries, in community-dwellers aged ≥ 45 years. DATA Inclusion criteria; participants aged ≥ 45 years, community-dwellers. Exclusion criteria; participants aged < 45 years, in nursing homes, data obtained from dental clinics or pre-2005. The quality assessment tool by The National Heart, Lung and Blood Institute for Observational Cohort and Cross-sectional studies was used. Meta-analysis using the random-effects model (95% confidence interval) was done with data on participants who were edentulous and/or had active dental caries and stratified by regions of the world, age and Gross National Income per capita. Limitations in the data arose from several factors such as design of the studies included differences in socioeconomic status and access to health care among different countries. SOURCES Embase, MEDLINE via Pubmed and Scopus, manual searches, from January 2016, restricted to English. Experts from different countries were contacted to identify National oral health surveys (NOHS) conducted from 2010 onwards. STUDY SELECTION Eighty-six papers and seventeen NOHS were selected for data extraction. Majority of the studies (n = 69) were cross-sectional and of fair quality. 1.1%-70%, 4.9% - 98% prevalence of edentulism and dental caries, respectively. 22%, 45% estimated random-effects pooled prevalence of edentulism and dental caries, respectively. CONCLUSIONS Within the limitations of this study, the findings indicate that untreated dental caries and tooth loss are prevalent on a global level with wide variations among different countries, age groups and socioeconomic status. CLINICAL SIGNIFICANCE The findings demonstrate the reality of the new cohort of older adults, with higher tooth retention implying more dental caries incidence and the need for different care strategies to ensure better oral health. Large variations and difficulty in making comparisons among different countries highlight the need for more standardized, regular research.
Collapse
Affiliation(s)
- R Borg-Bartolo
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, Bern 3012, Switzerland.
| | - A Roccuzzo
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, Bern 3012, Switzerland; Department of Periodontology, School of Dental Medicine, University of Bern, Switzerland.
| | - P Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - M Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - K Gambetta-Tessini
- Cariology Unit, Department of Oral Rehabilitation, University of Talca, Chile
| | - A Chaurasia
- Faculty of Dental Sciences, King George's Medical, India
| | - R B Koca-Ünsal
- Department of Periodontology, Faculty of Dentistry, University of Kyrenia, Cyprus
| | - C Tennert
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, Bern 3012, Switzerland
| | - R Giacaman
- Cariology Unit, Department of Oral Rehabilitation, University of Talca, Chile
| | - G Campus
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, Bern 3012, Switzerland; Department of Surgery, Microsurgery and Medicine Sciences, School of Dentistry, University of Sassari, Italy.
| |
Collapse
|
47
|
Arakawa‐Kaneko I, Watarai Y, Schimmel M, Abou‐Ayash S. Relationship between tongue pressure and handgrip strength: A systematic review and meta-analysis. J Oral Rehabil 2022; 49:1087-1105. [PMID: 35972300 PMCID: PMC9804501 DOI: 10.1111/joor.13362] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 06/23/2022] [Accepted: 08/09/2022] [Indexed: 01/05/2023]
Abstract
OBJECTIVES Muscle strength decreases with age, causing a decline in physical and oro-facial function. However, the impact of physiological and pathophysiological factors on tongue pressure (TP) has not been clarified. The purpose of this systematic review and meta-analysis was to compare and analyse TP and handgrip strength (HGS) between individuals aged <60 and ≥60 years, gender and need for care (independent older adults (IC) and older adults receiving nursing care (NC)). Furthermore, the effect of HGS in physical function on TP was examined. METHODS Human clinical studies reporting HGS and TP were searched systematically using PubMed and Ichushi-Web published from 1969 to Nov 2021. Random-effects meta-regressions were performed to compare between subgroups and to examine the association between HGS and TP (α < .05). RESULTS Forty-four studies with a total of 10 343 subjects were included. TP and HGS values were significantly higher in people aged <60 years relative to ≥60 years and in IC relative to NC (all p < .001). Regarding gender, there was no significant difference in TP (p = .370). However, a significant gender-dependent difference in TP was observed in people aged <60 years (p < .001), but not in aged ≥60 years in IC group (p = .118) and aged ≥60 years in NC group (p = .895). There was a significant positive correlation of HGS and TP (p < .001). CONCLUSIONS Similar to decrease in HGS, age-related sarcopaenia seems to have an effect on oro-facial muscles like the tongue. Research on rehabilitation measures for oro-facial muscle strength, similar to HGS might be beneficial to improve the personally acquired oro-facial potential.
Collapse
Affiliation(s)
- Itsuka Arakawa‐Kaneko
- Department of Reconstructive Dentistry and Gerodontology, School of Dental MedicineUniversity of BernBernSwitzerland,Comprehensive Dental Care UnitThe Nippon Dental University Niigata HospitalNiigataJapan
| | - Yuko Watarai
- Department of Removable ProsthodonticsThe Nippon Dental University School of Life Dentistry at NiigataNiigataJapan
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental MedicineUniversity of BernBernSwitzerland,Division of Gerodontology and Removable ProsthodonticsUniversity Clinics of Dental Medicine, University of GenevaGenevaSwitzerland
| | - Samir Abou‐Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental MedicineUniversity of BernBernSwitzerland
| |
Collapse
|
48
|
Yilmaz B, Donmez MB, Kahveci Ç, Cuellar AR, de Paula MS, Schimmel M, Abou-Ayash S, Çakmak G. Effect of printing layer thickness on the trueness and fit of additively manufactured removable dies. J Prosthet Dent 2022; 128:1318.e1-1318.e9. [DOI: 10.1016/j.prosdent.2022.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/31/2022] [Accepted: 10/31/2022] [Indexed: 11/25/2022]
|
49
|
Kim D, Banerdt WB, Ceylan S, Giardini D, Lekić V, Lognonné P, Beghein C, Beucler É, Carrasco S, Charalambous C, Clinton J, Drilleau M, Durán C, Golombek M, Joshi R, Khan A, Knapmeyer-Endrun B, Li J, Maguire R, Pike WT, Samuel H, Schimmel M, Schmerr NC, Stähler SC, Stutzmann E, Wieczorek M, Xu Z, Batov A, Bozdag E, Dahmen N, Davis P, Gudkova T, Horleston A, Huang Q, Kawamura T, King SD, McLennan SM, Nimmo F, Plasman M, Plesa AC, Stepanova IE, Weidner E, Zenhäusern G, Daubar IJ, Fernando B, Garcia RF, Posiolova LV, Panning MP. Surface waves and crustal structure on Mars. Science 2022; 378:417-421. [DOI: 10.1126/science.abq7157] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
We detected surface waves from two meteorite impacts on Mars. By measuring group velocity dispersion along the impact-lander path, we obtained a direct constraint on crustal structure away from the InSight lander. The crust north of the equatorial dichotomy had a shear wave velocity of approximately 3.2 kilometers per second in the 5- to 30-kilometer depth range, with little depth variation. This implies a higher crustal density than inferred beneath the lander, suggesting either compositional differences or reduced porosity in the volcanic areas traversed by the surface waves. The lower velocities and the crustal layering observed beneath the landing site down to a 10-kilometer depth are not a global feature. Structural variations revealed by surface waves hold implications for models of the formation and thickness of the martian crust.
Collapse
Affiliation(s)
- D. Kim
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
- Department of Geology, University of Maryland, College Park, MD, USA
| | - W. B. Banerdt
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
| | - S. Ceylan
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - D. Giardini
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - V. Lekić
- Department of Geology, University of Maryland, College Park, MD, USA
| | - P. Lognonné
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - C. Beghein
- Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, CA, USA
| | - É. Beucler
- Nantes Université, Université Angers, Le Mans Université, CNRS, UMR 6112, Laboratoire de Planétologie et Géosciences, Nantes, France
| | - S. Carrasco
- Bensberg Observatory, University of Cologne, Bergisch Gladbach, Germany
| | - C. Charalambous
- Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| | - J. Clinton
- Swiss Seismological Service, ETH Zürich, Zürich, Switzerland
| | - M. Drilleau
- Institut Supérieur de l’Aéronautique et de l’Espace ISAE-SUPAERO, Toulouse, France
| | - C. Durán
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - M. Golombek
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
| | - R. Joshi
- Max Planck Institute for Solar System Research, Göttingen, Germany
| | - A. Khan
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
- Physik-Institut, University of Zürich, Zürich, Switzerland
| | | | - J. Li
- Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, CA, USA
| | - R. Maguire
- Department of Geology, University of Illinois Urbana-Champaign, Champaign, IL, USA
| | - W. T. Pike
- Bensberg Observatory, University of Cologne, Bergisch Gladbach, Germany
| | - H. Samuel
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - M. Schimmel
- Geosciences Barcelona, CSIC, Barcelona, Spain
| | - N. C. Schmerr
- Department of Geology, University of Maryland, College Park, MD, USA
| | - S. C. Stähler
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - E. Stutzmann
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - M. Wieczorek
- Université Côte d’Azur, Observatoire de la Côte d’Azur, CNRS, Laboratoire Lagrange, Nice, France
| | - Z. Xu
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - A. Batov
- Schmidt Institute of Physics of the Earth, Russian Academy of Sciences, Moscow, Russia
| | - E. Bozdag
- Department of Geophysics, Colorado School of Mines, Golden, CO, USA
| | - N. Dahmen
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - P. Davis
- Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, CA, USA
| | - T. Gudkova
- Schmidt Institute of Physics of the Earth, Russian Academy of Sciences, Moscow, Russia
| | - A. Horleston
- School of Earth Sciences, University of Bristol, Bristol, UK
| | - Q. Huang
- Department of Geophysics, Colorado School of Mines, Golden, CO, USA
| | - T. Kawamura
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - S. D. King
- Department of Geosciences, Virginia Tech, Blacksburg, VA, USA
| | - S. M. McLennan
- Department of Geosciences, Stony Brook University, Stony Brook, NY, USA
| | - F. Nimmo
- Department of Earth and Planetary Sciences, University of California Santa Cruz, Santa Cruz, CA, USA
| | - M. Plasman
- Université Paris Cité, Institut de physique du globe de Paris, CNRS, Paris, France
| | - A. C. Plesa
- Institute of Planetary Research, German Aerospace Center (DLR), Berlin, Germany
| | - I. E. Stepanova
- Schmidt Institute of Physics of the Earth, Russian Academy of Sciences, Moscow, Russia
| | - E. Weidner
- Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, CA, USA
| | - G. Zenhäusern
- Institute of Geophysics, ETH Zürich, Zürich, Switzerland
| | - I. J. Daubar
- Department of Earth, Environmental, and Planetary Sciences, Brown University, Providence, RI, USA
| | - B. Fernando
- Department of Earth Sciences, University of Oxford, Oxford, UK
| | - R. F. Garcia
- Institut Supérieur de l’Aéronautique et de l’Espace ISAE-SUPAERO, Toulouse, France
| | | | - M. P. Panning
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
50
|
Çakmak G, Donmez MB, Akay C, Abou-Ayash S, Schimmel M, Yilmaz B. Effect of thermal cycling on the flexural strength and hardness of new-generation denture base materials. J Prosthodont 2022; 32:81-86. [PMID: 36266244 DOI: 10.1111/jopr.13615] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 10/17/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To evaluate the flexural strength and Vickers microhardness of different CAD-CAM denture base materials. MATERIALS AND METHODS Sixty rectangular specimens (64×10×3.3 ±0.2 mm) were fabricated from 3 different denture base materials (G-CAM, Graphene-reinforced polymethylmethacrylate, GC), Ivotion Base (Prepolymerized polymethylmethacrylate, IV), and Denturetec (3D-printed resin, DT) either by using additive (DT) or subtractive manufacturing (IV and GC). Specimens of each group were divided into 2 subgroups (thermal cycled or non-thermal cycled, n = 10/group). Non-thermal cycled specimens were stored in distilled water at 37°C for 24 hours and subjected to 3-point flexural strength test with a universal testing machine. Thermal cycled specimens were initially evaluated for Vickers microhardness and subjected to thermal cycling (10000 cycles at 5-55°C). Vickers microhardness values were re-measured, and the specimens were subjected to 3-point flexural strength test. Data were analyzed by using 2-way analysis of variance and Bonferroni-corrected Tukey honestly significant difference tests (α = .05). RESULTS Material type and condition significantly affected flexural strength (P≤.004), whereas their interaction was nonsignificant (P = .778). Overall flexural strength of the materials in decreasing order was GC, IV, and DT (P<.001), regardless of the condition. Material had a higher effect on flexural strength (ηp2 = .731) than thermal cycling (ηp2 = .142). The effect of the interaction between the material type and thermal cycling on Vickers microhardness was significant (P<.001). GC had the highest microhardness before and after thermal cycling (P<.001). IV had higher microhardness than DT before thermal cycling (P<.001). However, DT and IV showed similar microhardness after thermal cycling (P = .665). Thermal cycling decreased the microhardness of GC and IV (P≤.022), whereas its effect on DT's microhardness was nonsignificant (P = .538). Material type had the highest effect on microhardness (ηp2 = .864) followed by the interaction between the main factors (ηp2 = .258). CONCLUSIONS Graphene-reinforced polymethylmethacrylate had the highest flexural strength and Vickers microhardness values, regardless of thermal cycling. Thermal cycling reduced the flexural strength of all resins. Thermal cycling reduced the microhardness of milled polymethylmethacrylate, but not that of 3D-printed resin. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.,Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Canan Akay
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey
| | - Samir Abou-Ayash
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Privat-Docent extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.,Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| |
Collapse
|