1
|
Molinero-Mourelle P, Abou-Ayash S, Brägger U, Schimmel M, Özcan M, Yilmaz B, Buser R, Al-Haj Husain N. Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study. J Mech Behav Biomed Mater 2024; 151:106395. [PMID: 38244420 DOI: 10.1016/j.jmbbm.2024.106395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 01/08/2024] [Accepted: 01/08/2024] [Indexed: 01/22/2024]
Abstract
OBJECTIVES To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Switzerland
| | - Mutlu Özcan
- Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH, USA
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Nadin Al-Haj Husain
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
2
|
Südbeck S, Buser R, Reymus M, Hoffmann M, Edelhoff D, Stawarczyk B. A New Implant System with Directly Screwed Supraconstructions: Impact of Restoration Material and Artificial Aging on the Bending Moment. INT J PROSTHODONT 2023; 36:190-201. [PMID: 38112740 DOI: 10.11607/ijp.8102] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
PURPOSE To investigate the bending moment of implants restored with a directly screwed single-unit fixed dental prosthesis (FDP) compared to implants restored with an FDP polymerized to a titanium base before and after thermomechanical aging. MATERIALS AND METHODS A total of 240 implants (120 with and 120 without a titanium base) were restored with FDPs manufactured from conventionally sintered 3Y-TZP, 5Y-TZP, 4Y-TZP, and CoCrMo, as well as high-speed sintered 4Y-TZP. Half the specimens per subgroup were aged using chewing simulation combined with thermocycling (1,200,000 cycles at 50 N; 6,000 cycles at 5° to 55°). Initial and aged fracture load were measured. The bending moment was calculated and subjected to statistical analysis (Kolmogorov-Smirnov test, one-way ANOVA followed by post hoc Scheffé, t, and chi-square tests; P < .05). Failure types were analyzed. RESULTS Implants without a titanium base showed higher bending moments for all initially tested zirconia groups compared to implants with a titanium base. The highest initial values were observed for 4Y-TZP FDPs regardless of implant type. High-speed sintered FDPs demonstrated higher initial bending moments compared to conventionally sintered FDPs. Artificial aging led to a decrease of the bending moment in most subgroups. After aging, no differences were found within the restoration materials, sintering protocols, or implant types. Implant deformation occurred mainly with directly screwed FDPs, whereas FDP mobility was predominantly observed among implants with a titanium base. FDP fractures were mainly observed for 5Y-TZP. CONCLUSIONS Both implant types exhibited similar values after aging. Thus, implants without a titanium base seem to show equally sufficient stability for clinical applications with all tested materials.
Collapse
|
3
|
Schimmel M, Araujo M, Abou-Ayash S, Buser R, Ebenezer S, Fonseca M, Heitz-Mayfield LJ, Holtzman LP, Kamnoedboon P, Levine R, McKenna G, Maniewicz S, Matarazzo F, Mattheos N, Papaspyridakos P, De Souza AB, Srinivasan M, Stilwell C, Weber HP. Group 4 ITI Consensus Report: Patient benefits following implant treatment in partially and fully edentulous patients. Clin Oral Implants Res 2023; 34 Suppl 26:257-265. [PMID: 37750516 DOI: 10.1111/clr.14145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/07/2023] [Accepted: 07/11/2023] [Indexed: 09/27/2023]
Abstract
OBJECTIVES The aim of Working Group 4 was to address patient benefits associated with implant dentistry. Focused questions on (a) dental patient-reported outcomes (dPROs), (b) improvement in orofacial function, and (c) preservation of orofacial tissues in partially and fully edentulous patients following provision of implant-retained/supported dental prostheses were addressed. MATERIALS AND METHODS Three systematic reviews formed the basis for discussion. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary of the 7th ITI Consensus Conference, taking place in 2023 in Lisbon, Portugal. RESULTS Edentulous patients wearing complete dentures (CD) experience substantial improvements in overall dPROs and orofacial function following treatment with either complete implant-supported fixed dental prostheses (CIFDP) or implant overdentures (IODs). With respect to dPROs, mandibular IODs retained by two implants are superior to IODs retained by one implant. However, increasing the number of implants beyond two, does not further improve dPROs. In fully edentulous patients, rehabilitation with CIFDP or IOD is recommended to benefit the preservation of alveolar bone and masseter muscle thickness. CONCLUSIONS Completely edentulous patients benefit substantially when at least the mandible is restored using an CIFDP or an IOD compared to CD. In fully edentulous patients, implant prostheses are the best option for tooth replacement. The availability of this treatment modality should be actively promoted in all edentulous communities, including those with limited access and means.
Collapse
Affiliation(s)
- Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Mauricio Araujo
- Department of Dentistry, State University of Maringá, Maringá, Brazil
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Lucrezia Paterno Holtzman
- Department of Periodontics and Prosthodontics, Eastman Dental Hospital, University Policlinic "La Sapienza", Rome, Italy
| | - Porawit Kamnoedboon
- Clinic of General, Special Care, and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
- Chulalongkorn University, Bangkok, Thailand
| | - Robert Levine
- Kornberg School of Dentistry at Temple University, Philadelphia, Pennsylvania, USA
| | - Gerry McKenna
- Centre for Public Health, Queen's University Belfast, Belfast, UK
| | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Flavia Matarazzo
- Department of Dentistry, State University of Maringá, Maringá, Brazil
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Panos Papaspyridakos
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| | | | - Murali Srinivasan
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Clinic of General, Special Care, and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Charlotte Stilwell
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
- Private Practice, London, UK
| | - Hans Peter Weber
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Mayinger F, Buser R, Laier M, Schönhoff LM, Kelch M, Hampe R, Stawarczyk B. Impact of the material and sintering protocol, layer thickness, and thermomechanical aging on the two-body wear and fracture load of 4Y-TZP crowns. Clin Oral Investig 2022; 26:6617-6628. [PMID: 35840737 DOI: 10.1007/s00784-022-04616-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 07/04/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns. MATERIALS AND METHODS Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.0 mm/1.5 mm) were sintered by high-speed (Zolid RS) or conventional (Zolid Gen-X) sintering. 2BW of ceramic and enamel antagonist after aging (1,200,000 mechanical-, 6000 thermal-cycles) was determined by 3D-scanning before and after aging and subsequent matching to determine volume and height loss (6 subgroups, n = 16/subgroup). FL was examined initially and after aging (12 subgroups, n = 16/subgroup). Fractographic analyses were performed using light-microscope imaging. Global univariate analysis of variance, one-way ANOVA, linear regression, Spearman's correlation, Kolgomorov-Smirnov, Mann-Whitney U, and t test were computed (alpha = 0.05). Weibull moduli were determined. Fracture types were analyzed using Ciba Geigy table. RESULTS Material/sintering protocol did not influence 2BW (crowns: p = 0.908, antagonists: p = 0.059). High-speed sintered Zolid RS presented similar (p = 0.325-0.633) or reduced (p < 0.001-0.047) FL as Zolid Gen-X. Both 4Y-TZPs showed an increased FL with an increasing thickness (0.5(797.3-1429 N) < 1.0(2087-2634 N) < 1.5(2683-3715 N)mm; p < 0.001). For most groups, aging negatively impacted FL (p < 0.001-0.002). Five 0.5 mm specimens fractured, four showed cracks during and after aging. CONCLUSIONS High-speed sintered crowns with a minimum thickness of 1.0 mm showed sufficient mechanical properties to withstand masticatory forces, even after a simulated aging period of 5 years. CLINICAL RELEVANCE Despite the manufacturer indicating a thickness of 0.5 mm to be suitable for single crowns, a minimum thickness of 1.0 mm should be used to ensure long-term satisfactory results.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Ramona Buser
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.,Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007, Bern, Switzerland
| | - Maximilian Laier
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Lisa Marie Schönhoff
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Matthias Kelch
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Rüdiger Hampe
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
5
|
Hensel J, Reise M, Liebermann A, Buser R, Stawarczyk B. Impact of multiple firings on fracture load of veneered zirconia restorations. J Mech Behav Biomed Mater 2022; 130:105213. [DOI: 10.1016/j.jmbbm.2022.105213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 03/23/2022] [Accepted: 03/26/2022] [Indexed: 11/17/2022]
|
6
|
Hensel J, Reise M, Liebermann A, Buser R, Stawarczyk B. Impact of multiple firings on thermal properties and bond strength of veneered zirconia restorations. J Mech Behav Biomed Mater 2022; 128:105134. [DOI: 10.1016/j.jmbbm.2022.105134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/09/2022] [Accepted: 02/13/2022] [Indexed: 10/19/2022]
|
7
|
Fonseca M, Molinero-Mourelle P, Buser R, Yilmaz B, Schimmel M. Fabrication of an implant-retained overdenture with ceramic crowns cemented on a polyetherketoneketone framework: A clinical report. J Prosthet Dent 2021; 128:1152-1157. [PMID: 33994192 DOI: 10.1016/j.prosdent.2021.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/02/2021] [Accepted: 04/05/2021] [Indexed: 10/21/2022]
Abstract
This clinical report describes the treatment of a complex intraoral situation by fabricating a maxillary implant-retained overdenture with a high-performance polymer (polyetherketoneketone) framework and lithium disilicate crowns and mandibular tooth- and implant-supported ceramic restorations. No complications were noted in 2 years, and the patient was satisfied with function and esthetics.
Collapse
Affiliation(s)
- Manrique Fonseca
- Senior Lecturer, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Pedro Molinero-Mourelle
- Resident, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Senior Lecturer, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Martin Schimmel
- Professor and Chair, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Senior Lecturer, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
8
|
Schönhoff LM, Lümkemann N, Buser R, Hampe R, Stawarczyk B. Fatigue resistance of monolithic strength-gradient zirconia materials. J Mech Behav Biomed Mater 2021; 119:104504. [PMID: 33845296 DOI: 10.1016/j.jmbbm.2021.104504] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/24/2021] [Accepted: 03/29/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE Evaluation of the effect of three different dynamic fatigue protocols on the fracture resistance of two monolithic strength-gradient zirconia materials. MATERIALS AND METHODS A total of 240 specimens (3 × 4 × 45 mm) was milled from two different layers (incisal and middle) of two types of strength-gradient zirconia blanks (IPS e. max ZirCAD MT Multi A2 vs. IPS e. max ZirCAD Prime A2), resulting in 60 specimens per material and layer group (IPS e. max ZirCAD MT Multi A2: incisal (MI), middle (MM); IPS e. max ZirCAD Prime A2: incisal (PI), middle (PM)). Each group was divided into one static (n = 15) and three dynamic fatigue protocols (N = 45, n = 15): i. 50 N increase every 5000 cycles ii. Increase by 5% of static fracture load every 5000 cycles iii. 10 N increase every 1000 cycles until facture. All specimens were loaded until facture in CeraTest 2 k. Kaplan-Meier, Log-Rank and Chi-squared-test as well as Weibull statistics were performed. A fractographic analysis was performed. The specimens were classified according to the number of crack origins and evaluated using the Ciba-Geigy table. RESULTS With regard to the fracture load, in the static loading MI and PI showed a higher fracture load and in dynamic fatigue protocol 2 PI showed a lower fracture load. The number of cycles until fracture only differed within three groups: MM and MI survived a higher number of cycles in dynamic fatigue protocol 2; PI survived a higher number of cycles in dynamic fatigue protocol 2 than in protocol 1. Within dynamic fatigue protocols, PM resisted the highest number of cycles in protocol 1 and 3 and MI in protocol 2. Comparing groups, Weibull modulus differed only within the static loading, with PI showing lower values than MM and MI. Within the material groups, MI showed higher values in static loading than in dynamic fatigue protocol 1 and 2, and PI showed higher values in the dynamic fatigue protocol 3 than in static loading. With regard to fracture patterns, no differences were found between the groups. CONCLUSIONS Dynamic fatigue protocols provide clinically relevant information on the long-term stability and reliability of monolithic strength-gradient zirconia materials. However, no definitive instructions for dynamic testing can be provided from this investigation.
Collapse
Affiliation(s)
- Lisa Marie Schönhoff
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Nina Lümkemann
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Ramona Buser
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Rüdiger Hampe
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| |
Collapse
|
9
|
Stalder A, Berger CH, Buser R, Wittneben J, Schimmel M, Abou-Ayash S. Biological and technical complications in root cap-retained overdentures after 3-15 years in situ: a retrospective clinical study. Clin Oral Investig 2021; 25:2325-2333. [PMID: 32895768 PMCID: PMC7966125 DOI: 10.1007/s00784-020-03555-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 08/27/2020] [Indexed: 10/25/2022]
Abstract
OBJECTIVES This retrospective clinical study investigates the frequency of biological and technical complications in patients rehabilitated by natural root-retained overdentures (RODs) with cast post-and-cores (root caps) wearing precision attachments and analyses factors influencing complication rates (e.g. oral hygiene routines). MATERIALS AND METHODS Patients formerly treated with RODs were invited for a cost-free clinical visit to evaluate their intraoral status. Furthermore, they were interviewed and patient records were screened for complications occurring since denture delivery. Statistical models include descriptive analyses, Fisher's exact test, odds ratios, and a multivariate regression model. RESULTS A total of 114 patients wearing 128 RODs with a total of 280 abutment teeth were evaluated (mean service time: 7.9 years). Technical complications occurred in 68.8% of the RODs, with matrix loosening being the most frequent complication (50.1%). Biological complications occurred in 53.9% of all RODs, with the presence of denture stomatitis being the most common biological complication (38.3%). The presence of denture stomatitis was significantly higher in the maxilla relative to the mandible (p = 0.0029), in subjects cleaning their dentures less than twice a day (p < 0.001), in subjects regularly using CHX-containing products (p = 0.036) and in subjects with a plaque index > 40% (p < 0.001). CONCLUSIONS Root cap-retained overdentures with precision attachments are a viable treatment option in partially dentate subjects, even over long-term periods. However, high complication rates should be expected. CLINICAL RELEVANCE Establishing good oral hygiene is a decisive factor in preventing complications in RODs. Furthermore, CHX-containing products may not be recommended for routine domestic use.
Collapse
Affiliation(s)
- Anja Stalder
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Camille Henriette Berger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Julia Wittneben
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
10
|
Srinivasan M, Schimmel M, Buser R, Maniewicz S, Herrmann FR, Müller F. Mandibular two-implant overdentures with CAD-CAM milled bars with distal extensions or retentive anchors: A randomized controlled trial. Clin Oral Implants Res 2020; 31:1207-1222. [PMID: 32965052 DOI: 10.1111/clr.13668] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 08/28/2020] [Accepted: 09/11/2020] [Indexed: 01/23/2023]
Abstract
OBJECTIVE This randomized controlled trial (RCT) aimed to demonstrate the non-inferiority of mandibular 2-implant overdentures (IODs) on a CAD-CAM milled bar with long distal extensions (MBDE) against IODs on retentive anchors (RA). METHODS Forty edentulous participants rehabilitated with a maxillary conventional denture and a mandibular 2-IOD participated in this trial. They were randomized into two groups [Control group (CG): RA + gold matrices; Experimental group (EG): MBDE + gold clip]. The outcomes included implant survival rate (ISR), chewing efficiency [quantitative (VoH) and subjective (SA) assessments], peri-implant marginal bone levels (PI-MBL), maximum bite force (MBF), and patient-reported outcomes [oral health impact profile (OHIP-EDENT), and denture satisfaction index (DSI)]. Outcomes were recorded at baseline (BL), two weeks (T0 ), 6 months (T1 ), and at 1 year (T2 ) after the intervention. Intra- and inter-group analyses were performed using regression models with ⍺=0.05. RESULTS 38 participants completed the T2 visit (CG: n = 19, age = 74.7 ± 7.8 years; EG: n = 19, age = 70.3 ± 10.7 years). At T2 , there was no implant loss in either of the groups (ISR = 100%). There were no significant differences between the groups for the PI-MBL changes (p = .754). Improvements occurred faster in the EG than in the CG, but over the observation time, there were no differences between the trial groups for VoH, MBF, OHIP-EDENT, and the DSI, except for SA being significantly better in the EG group (p = .022). CONCLUSIONS The results of this RCT confirm that mandibular 2-IODs with a CAD-CAM milled bar with long distal extensions are not an inferior treatment to the conventional IODs on retentive anchors in the short term (1 year).
Collapse
Affiliation(s)
- Murali Srinivasan
- Center of General, Special Care, & Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Sabrina Maniewicz
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - François R Herrmann
- Division of Geriatrics, Department of Rehabilitation and Geriatics, Geneva University Hospitals, Trois-Chêne, Geneva, Switzerland
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.,Service of Geriatrics, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
11
|
El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin Oral Implants Res 2019; 30:1067-1075. [PMID: 31381178 DOI: 10.1111/clr.13520] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 06/03/2019] [Accepted: 07/22/2019] [Indexed: 12/30/2022]
Abstract
OBJECTIVE To investigate the effect of surgical guide support and implant site location on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous patients. MATERIALS AND METHODS 375 replica implants were inserted in 85 study models. Surgical implant placement was done using static 3D printed surgical guides, which were designed to be supported either by all the teeth present in the model (full arch), or by 4-teeth), 3-teeth or 2-teeth. Each study model included three single-tooth gap (STG) situations; one extraction socket site and two implants placed in a distal extension situation. Preplanned and postoperative implant positions were compared using the treatment-evaluation tool in digital software. 3-dimensional and angular deviations were measured. Statistical analysis was done using ANOVA, and pairwise t tests and Bonferroni-Holm's adjustment were applied as a post hoc test. RESULTS Accuracy of surgical guides used in sCAIS was significantly affected by the number and type of teeth used for its support. Guides supported by 4 teeth were not significantly different from accuracy of full-arch-supported guides (p > .05). Guide support by posterior teeth was associated with an increased level of accuracy, when compared to anterior teeth guide support. Implants placed in extraction sockets were associated with significantly higher 3D and angular deviation values (p < .05), and surgical guides with a distal extension situation resulted in significantly higher deviation values (p < .05). CONCLUSION The number and location of teeth supporting the surgical guide can significantly influence the accuracy of sCAIS, with 4 teeth providing equal accuracy to full-arch guides in (STG) situations.
Collapse
Affiliation(s)
- Karim El Kholy
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Periodontology, Harvard School of Dental Medicine, Boston, Massachusetts
| | - Rafael Lazarin
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Simone F M Janner
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Karin Faerber
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Daniel Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
12
|
Chappuis V, Shahim K, Buser R, Koller E, Joda T, Reyes M, Buser D. Novel Collagen Matrix to Increase Tissue Thickness Simultaneous with Guided Bone Regeneration and Implant Placement in Esthetic Implant Sites: A Feasibility Study. INT J PERIODONT REST 2018; 38:575-582. [PMID: 29889921 DOI: 10.11607/prd.3700] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this case series was to assess safety and feasibility of a novel resorbable collagen matrix (CMX) to enhance tissue thickness simultaneous with implant placement and guided bone regeneration (GBR) in esthetic sites over an 8-week healing period. Soft tissue thickness at implant sites and adjacent teeth was monitored with an ultrasonic device. Overall tissue contour changes were assessed by sequential digital surface model superimpositions. Periodontal parameters and patient-related outcomes revealed no significant changes. Combining a novel CMX and GBR revealed a significant soft tissue thickness increase of 1.56 mm at implant sites after 8 weeks, with no significant decrease between 4 and 8 weeks. The overall tissue contour increase was most significant at a distance of 5 mm from the mucosal margin, corresponding to a tissue increase at the implant shoulder area. No effect was observed at adjacent teeth after 8 weeks.
Collapse
|
13
|
Buser R, Ziltener V, Samietz S, Fontolliet M, Nef T, Schimmel M. Validation of a purpose-built chewing gum and smartphone application to evaluate chewing efficiency. J Oral Rehabil 2018; 45:845-853. [PMID: 30024031 DOI: 10.1111/joor.12696] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 07/02/2018] [Accepted: 07/16/2018] [Indexed: 12/28/2022]
Abstract
OBJECTIVES To validate a purpose-built two-coloured chewing gum (Hue-Check Gum® ), and to test the accuracy of a custom-built smartphone application for a colour-mixing ability test to assess chewing function. METHODS Fully dentate participants (28D-group) and edentulous participants with implant overdentures (IOD-group) were recruited. They chewed a Hue-Check Gum® for 5, 10, 20, 30 and 50 chewing cycles, respectively. Maximum voluntary bite force (MBF) was assessed with a digital gauge. The specimens were analysed according to their colour mixture (variance of hue, VOH) with a validated software (VOH_scan) and a newly developed smartphone application (VOH_app). RESULTS Participants segregated by dental state were significantly different regarding the number of occluding pairs of teeth, age and MBF. VOH_scan showed a negative logarithmic association with the number of chewing cycles, and VOH could be predicted from chewing cycles, MBF and gender. The clearest discrimination between the IOD and the 28D groups was observed for n = 20 chewing cycles; at this point, VOH was distinguishably different with a P-value < 0.0001. The VOH_app was a very good predictor for VOH_scan with 0.80 < pseudo-R2 < 0.83, depending on light exposure and measuring distance. There was, however, a systematic error in the accuracy of the app for inadequately chewed specimens. CONCLUSIONS The use of the two-coloured chewing gum would provide a fast, simple and inexpensive method for the assessment of masticatory performance, which could be used in geriatric wards or in private practices without the requirement of specialised equipment or trained staff.
Collapse
Affiliation(s)
- Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Valerie Ziltener
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Stefanie Samietz
- Department of Prosthodontics, Gerostomatology and Biomaterials, Center for Oral Health, University Medicine Greifswald, Greifswald, Germany
| | - Marta Fontolliet
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Tobias Nef
- Gerontechnology & Rehabilitation Group, University of Bern, Bern, Switzerland.,ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
14
|
Chappuis V, Rahman L, Buser R, Janner S, Belser U, Buser D. Effectiveness of Contour Augmentation with Guided Bone Regeneration: 10-Year Results. J Dent Res 2017; 97:266-274. [DOI: 10.1177/0022034517737755] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- V. Chappuis
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - L. Rahman
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - R. Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - S.F.M. Janner
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - U.C. Belser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - D. Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
15
|
Maniewicz S, Buser R, Duvernay E, Vazquez L, Loup A, Perneger T, Schimmel M, Müller F. Short Dental Implants Retaining Two-Implant Mandibular Overdentures in Very Old, Dependent Patients: Radiologic and Clinical Observation Up to 5 Years. Int J Oral Maxillofac Implants 2017; 32:415-422. [DOI: 10.11607/jomi.5361] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
16
|
Buser D, Chappuis V, Kuchler U, Bornstein MM, Wittneben JG, Buser R, Cavusoglu Y, Belser UC. Long-term stability of early implant placement with contour augmentation. J Dent Res 2013; 92:176S-82S. [PMID: 24158332 DOI: 10.1177/0022034513504949] [Citation(s) in RCA: 132] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.
Collapse
Affiliation(s)
- D Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Chappuis V, Buser R, Brägger U, Bornstein MM, Salvi GE, Buser D. Long-term outcomes of dental implants with a titanium plasma-sprayed surface: a 20-year prospective case series study in partially edentulous patients. Clin Implant Dent Relat Res 2013; 15:780-90. [PMID: 23506385 DOI: 10.1111/cid.12056] [Citation(s) in RCA: 110] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
BACKGROUND Long-term studies of ≥10 years are important milestones to get a better understanding of potential factors causing implant failures or complications. PURPOSE The present study investigated the long-term outcomes of titanium dental implants with a rough, microporous surface (titanium plasma sprayed [TPS]) and the associated biologic and technical complications in partially edentulous patients with fixed dental prostheses over a 20-year follow-up period. MATERIALS AND METHODS Sixty-seven patients, who received 95 implants in the 1980s, were examined with well-established clinical and radiographic parameters. Based on these findings, each implant was classified as either successful, surviving, or failed. RESULTS Ten implants in nine patients were lost during the observation period, resulting in an implant survival rate of 89.5%. Radiographically, 92% of the implants exhibited crestal bone loss below 1 mm between the 1- and 20-year follow-up examinations. Only 8% yielded peri-implant bone loss of >1 mm and none exhibited severe bone loss of more than 1.8 mm. During the observation period, 19 implants (20%) experienced a biologic complication with suppuration. Of these 19 implants, 13 implants (13.7%) had been treated and were successfully maintained over the 20-year follow-up period. Therefore, the 20-year implant success rate was 75.8 or 89.5% depending on the different success criteria. Technical complications were observed in 32%. CONCLUSION The present study is the first to report satisfactory success rates after 20 years of function of dental implants with a TPS surface in partially edentulous patients.
Collapse
Affiliation(s)
- Vivianne Chappuis
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | | | | | | | | |
Collapse
|
18
|
Sappino AP, Buser R, Seguin Q, Fernet M, Lesne L, Gumy-Pause F, Reith W, Favaudon V, Mandriota SJ. The CEACAM1 tumor suppressor is an ATM and p53-regulated gene required for the induction of cellular senescence by DNA damage. Oncogenesis 2012; 1:e7. [PMID: 23552604 PMCID: PMC3412640 DOI: 10.1038/oncsis.2012.7] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The p53 tumor-suppressor protein has a key role in the induction of cellular senescence, an important barrier to cancer development. However, very little is known about the physiological mediators of cellular senescence induced by p53. CEACAM1 is an immunoglobulin superfamily member whose expression is frequently lost in human tumors and exhibits tumor-suppressor features in several experimental systems, including Ceacam1 knockout mice. There is currently little understanding of the pathways and mechanisms by which CEACAM1 exerts its tumor-suppressor function. Here we report that CEACAM1 is strongly upregulated during the cellular response to DNA double-strand breaks (DSBs) starting from the lowest doses of DSB inducers used, and that upregulation is mediated by the ataxia telangiectasia mutated (ATM)/p53 pathway. Stable silencing of CEACAM1 showed that CEACAM1 is required for p53-mediated cellular senescence, but not initial cell growth arrest, in response to DNA damage. These findings identify CEACAM1 as a key component of the ATM/p53-mediated cellular response to DNA damage, and as a tumor suppressor mediating cellular senescence downstream of p53.
Collapse
Affiliation(s)
- A-P Sappino
- Clinique des Grangettes, Geneva, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Blanpain C, Buser R, Power CA, Edgerton M, Buchanan C, Mack M, Simmons G, Clapham PR, Parmentier M, Proudfoot AE. A chimeric MIP-1alpha/RANTES protein demonstrates the use of different regions of the RANTES protein to bind and activate its receptors. J Leukoc Biol 2001; 69:977-85. [PMID: 11404385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023] Open
Abstract
Human RANTES (CCL5) and MIP-1alpha (CCL3) bind and activate several CC chemokine receptors. RANTES is a high-affinity ligand for CCR1 and CCR5, and it binds CCR3 with moderate affinity and CCR4 with low affinity. MIP-1alpha has similar binding characteristics to RANTES except that it does not bind to CCR3. Here we have generated a chimera of human MIP-1alpha and RANTES, called MIP/RANTES, consisting of the eight amino terminal residues of MIP-1alpha preceding the CC motif, and the remainder of the sequence is RANTES. The chimera is able to induce chemotaxis of human monocytes. MIP/RANTES has >100-fold reduction in binding to CCR1 and does not bind to CCR3 but retains full, functional binding to CCR5. It has equivalent affinity for CCR5 to MIP-1alpha and RANTES, binding with an IC(50) of 1.12 nM, and is able to mobilize calcium and induce endocytosis of CCR5 in PBMC in a manner equi-potent to RANTES. It also retains the ability to inhibit R5 using HIV-1 strains. Therefore, we conclude that the amino terminus of RANTES is not involved in CCR5 binding, but it is essential for CCR1 and CCR3.
Collapse
Affiliation(s)
- C Blanpain
- IRIBHN Université Libre de Bruxelles, Campus Erasme, Bruxelles, Belgium
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Affiliation(s)
- R Buser
- Serono Pharmaceutical Research Institute S A, Geneva, Switzerland
| | | |
Collapse
|
21
|
|
22
|
Chvatchko Y, Hoogewerf AJ, Meyer A, Alouani S, Juillard P, Buser R, Conquet F, Proudfoot AE, Wells TN, Power CA. A key role for CC chemokine receptor 4 in lipopolysaccharide-induced endotoxic shock. J Exp Med 2000; 191:1755-64. [PMID: 10811868 PMCID: PMC2193157 DOI: 10.1084/jem.191.10.1755] [Citation(s) in RCA: 222] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
CC chemokine receptor (CCR)4, a high affinity receptor for the CC chemokines thymus and activation-regulated chemokine (TARC) and macrophage-derived chemokine (MDC), is expressed in the thymus and spleen, and also by peripheral blood T cells, macrophages, platelets, and basophils. Recent studies have shown that CCR4 is the major chemokine receptor expressed by T helper type 2 (Th2) polarized cells. To study the in vivo role of CCR4, we have generated CCR4-deficient (CCR4(-/-)) mice by gene targeting. CCR4(-/-) mice developed normally. Splenocytes and thymocytes isolated from the CCR4(-/-) mice failed to respond to the CCR4 ligands TARC and MDC, as expected, but also surprisingly did not undergo chemotaxis in vitro in response to macrophage inflammatory protein (MIP)-1alpha. The CCR4 deletion had no effect on Th2 differentiation in vitro or in a Th2-dependent model of allergic airway inflammation. However, CCR4(-/-) mice exhibited significantly decreased mortality on administration of high or low dose bacterial lipopolysaccharide (LPS) compared with CCR4(+/+) mice. After high dose LPS treatment, serum levels of tumor necrosis factor alpha, interleukin 1beta, and MIP-1alpha were reduced in CCR4(-/-) mice, and decreased expression of MDC and MIP-2 mRNA was detected in peritoneal exudate cells. Analysis of peritoneal lavage cells from CCR4(-/)- mice by flow cytometry also revealed a significant decrease in the F4/80(+) cell population. This may reflect a defect in the ability of the CCR4(-/-) macrophages to be retained in the peritoneal cavity. Taken together, our data reveal an unexpected role for CCR4 in the inflammatory response leading to LPS-induced lethality.
Collapse
Affiliation(s)
- Y Chvatchko
- Serono Pharmaceutical Research Institute, 1228 Plan-les-Ouates/Geneva, Switzerland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Abstract
Recent observations indicate that the Milky Way may have formed by aggregation of gas and stars from a reservoir of preexisting small galaxies in the local universe. The process probably began more than 12 billion years ago with material of different original angular momentum following two separate evolutionary lines, one into the slowly rotating halo and central bulge and the other into the rapidly rotating disk. The existence of distinct thick and thin disks shows that continuing mergers of satellite galaxies likely also determined the early evolution of the main structural component of the luminous Galaxy.
Collapse
Affiliation(s)
- R Buser
- Astronomisches Institut der Universität Basel, Venusstrasse 7, CH-4102 Binningen, Switzerland.
| |
Collapse
|
24
|
Proudfoot AE, Buser R, Borlat F, Alouani S, Soler D, Offord RE, Schröder JM, Power CA, Wells TN. Amino-terminally modified RANTES analogues demonstrate differential effects on RANTES receptors. J Biol Chem 1999; 274:32478-85. [PMID: 10542293 DOI: 10.1074/jbc.274.45.32478] [Citation(s) in RCA: 114] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Modification of the amino terminus of regulated on activated normal T-cell expressed (RANTES) has been shown to have a significant effect on biological activity and produces proteins with antagonist properties. Two amino-terminally modified RANTES proteins, Met-RANTES and aminooxypentane-RANTES (AOP-RANTES), exhibit differential inhibitory properties on both monocyte and eosinophil chemotaxis. We have investigated their binding properties as well as their ability to activate the RANTES receptors CCR1, CCR3, and CCR5 in cell lines overexpressing these receptors. We show that Met-RANTES has weak activity in eliciting a calcium response in Chinese hamster ovary cells expressing CCR1, CCR3, and CCR5, whereas AOP-RANTES has full agonist activity on CCR5 but is less effective on CCR3 and CCR1. Their ability to induce chemotaxis of the murine pre-B lymphoma cell line, L1.2, transfected with the same receptors, consolidates these results. Monocytes have detectable mRNA for CCR1, CCR2, CCR3, CCR4, and CCR5, and they respond to the ligands for these receptors in chemotaxis but not always in calcium mobilization. AOP-RANTES does not induce calcium mobilization in circulating monocytes but is able to do so as these cells acquire the macrophage phenotype, which coincides with a concomitant up-regulation of CCR5. We have also tested the ability of both modified proteins to induce chemotaxis of freshly isolated monocytes and eosinophils. Cells from most donors do not respond, but occasionally cells from a particular donor do respond, particularly to AOP-RANTES. We therefore hypothesize that the occasional activity of AOP-RANTES to induce leukocyte chemotaxis is due to donor to donor variation of receptor expression.
Collapse
Affiliation(s)
- A E Proudfoot
- Serono Pharmaceutical Research Institute, 14 Chemin des Aulx, 1228 Plan-les-Ouates, Geneva, Switzerland.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
|
26
|
|
27
|
|
28
|
Simmons G, Clapham PR, Picard L, Offord RE, Rosenkilde MM, Schwartz TW, Buser R, Wells TN, Proudfoot AE. Potent inhibition of HIV-1 infectivity in macrophages and lymphocytes by a novel CCR5 antagonist. Science 1997; 276:276-9. [PMID: 9092481 DOI: 10.1126/science.276.5310.276] [Citation(s) in RCA: 453] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The chemokine receptors CXCR4 and CCR5 have recently been shown to act as coreceptors, in concert with CD4, for human immunodeficiency virus-type 1 (HIV-1) infection. RANTES and other chemokines that interact with CCR5 and block infection of peripheral blood mononuclear cell cultures inhibit infection of primary macrophages inefficiently at best. If used to treat HIV-1-infected individuals, these chemokines could fail to influence HIV replication in nonlymphocyte compartments while promoting unwanted inflammatory side effects. A derivative of RANTES that was created by chemical modification of the amino terminus, aminooxypentane (AOP)-RANTES, did not induce chemotaxis and was a subnanomolar antagonist of CCR5 function in monocytes. It potently inhibited infection of diverse cell types (including macrophages and lymphocytes) by nonsyncytium-inducing, macrophage-tropic HIV-1 strains. Thus, activation of cells by chemokines is not a prerequisite for the inhibition of viral uptake and replication. Chemokine receptor antagonists like AOP-RANTES that achieve full receptor occupancy at nanomolar concentrations are strong candidates for the therapy of HIV-1-infected individuals.
Collapse
Affiliation(s)
- G Simmons
- Virology Group, Chester Beatty Laboratories, Institute of Cancer Research, 237 Fulham Road, London SW3 6JB, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Häusler A, Persoz C, Buser R, Mondadori C, Bhatnagar A. Adrenalectomy, corticosteroid replacement and their importance for drug-induced memory-enhancement in mice. J Steroid Biochem Mol Biol 1992; 41:785-9. [PMID: 1314083 DOI: 10.1016/0960-0760(92)90425-i] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Adrenalectomy blocks the memory-improving effect of piracetam-like compounds in mice. If this blockade is due to the removal of endogenous corticosteroids, replacement therapy with exogenous corticosteroids should reinstate the effects on memory. The present experiments were designed to determine the appropriate replacement dose (concentration in the drinking fluid) for corticosterone and aldosterone, the main corticosteroids in mice. Based on the effects of corticosterone on thymus weight, replacement with 3 micrograms/ml corticosterone given in the drinking fluid (0.9% NaCl) for one week was found to be appropriate. The appropriate replacement dose for aldosterone was found by giving aldosterone to adrenalectomized (ADX) mice in the drinking fluid in combination with 3 micrograms/ml corticosterone. The combination of 3 micrograms/ml corticosterone + 30 ng/ml aldosterone resulted in a plasma ratio of corticosterone/aldosterone which most closely approximated the ratio seen in sham-ADX control animals. The physiologic adequacy of the corticosteroid replacement doses resulting from this study were clearly demonstrated in subsequent behavioral experiments where blockade of the memory-enhancing effects of piracetam by adrenalectomy were overcome by replacement with either 3 micrograms/ml corticosterone or 30 ng/ml aldosterone given in the drinking fluid.
Collapse
Affiliation(s)
- A Häusler
- Research Department, Pharmaceuticals Division, CIBA-GEIGY Ltd., Basel, Switzerland
| | | | | | | | | |
Collapse
|