Tang WY, Chen JM, Wang RR, Tan SL, Liu DM, Yu XY, Li HH, Zhang QF, Sheng YL, Xia WT. [Application of the Virtual Reality-Pattern Visual Evoked Potential in Forensic Visual Acuity Evaluation]. Fa Yi Xue Za Zhi 2021; 36:762-766. [PMID: 33550723 DOI: 10.12116/j.issn.1004-5619.2020.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Indexed: 11/30/2022]
Abstract
Abstract Objective To explore a kind of visual evoked potential test equipment and method that is more suitable for the application of forensic clinical visual acuity evaluation. Methods Thirty-four volunteers (68 eyes) were selected, including 15 males and 19 females, aged between 20 and 40 years. Test lenses were placed before the tested eyes of volunteers to induce refractive myopia with insert method, and the diopter lenses were adjusted so that the visual acuity level of one eye of volunteers was above 0.8, and the visual acuity of the other eye was at moderate damage level (<0.3 and ≥0.1). The tests were carried out under the binocular simultaneous asynchronous stimulation mode (hereinafter referred to as "binocular mode") and monocular separate stimulation mode (hereinafter referred to as "monocular mode") of virtual reality-pattern visual evoked potential (VR-PVEP), and the amplitude of PVEP of volunteers under the two modes was compared at four spatial frequencies of 8×8, 16×16, 24×24 and 32×32. Results The differences in the amplitude of P100 wave between monocular and binocular modes at 8×8 spatial frequency had no statistical significance and the differences in amplitude of P100 wave between monocular and binocular modes at 16×16, 24×24, and 32×32 spatial frequencies had statistical significance (P<0.05). The amplitude of the same eye in monocular mode was higher than that in binocular mode. Through correlation analysis, it was found that the amplitude of P100 wave in monocular mode was moderately correlated with amplitude of P100 wave in binocular mode. Conclusion In forensic identification practice, VR-PVEP is helpful for overcoming the disturbance of poor fixation, and to increase the reliability of PVEP evaluation results. It can greatly shorten the detection time of PVEP and improve work efficiency.
Collapse
Affiliation(s)
- W Y Tang
- Basic Medical College of Jiamusi University, Jiamusi 154007, Heilongjiang Province, China
| | - J M Chen
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - R R Wang
- Shanghai NCC Electronic Corp., Ltd, Shanghai 200063, China
| | - S L Tan
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - D M Liu
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - X Y Yu
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - H H Li
- Shanghai NCC Electronic Corp., Ltd, Shanghai 200063, China
| | - Q F Zhang
- Shanghai NCC Electronic Corp., Ltd, Shanghai 200063, China
| | - Y L Sheng
- Basic Medical College of Jiamusi University, Jiamusi 154007, Heilongjiang Province, China
| | - W T Xia
- Basic Medical College of Jiamusi University, Jiamusi 154007, Heilongjiang Province, China.,Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
2
|
Chen SW, Cui DN, Xia Q, Xia WT, Jiang JQ, Shen YW. Application of Convolutional Neural Network in Identifying Different Levels of Isokinetic Exercise Efforts. Fa Yi Xue Za Zhi 2020; 36:210-215. [PMID: 32530169 DOI: 10.12116/j.issn.1004-5619.2020.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Indexed: 06/11/2023]
Abstract
Objective To develop a convolutional neural network (CNN) that can identify isokinetic knee exercises moment of force-time diagrams under different levels of efforts. Methods The 200 healthy young volunteers performed concentric isokinetic right knee flexion-extension reciprocating exercises with maximal effort as well as half the effort at angular velocities of 30°/s and 60°/s twice, respectively, with an interval of 45 min. The moment of force-time diagrams were collected. The 200 subjects were randomly divided into the training set (140 subjects) and the testing set (60 subjects). The moment of force-time diagrams from subjects in the training set were used to train CNN model, and then the fully trained model was used to predict types of curves from the testing set. Random sampling of subjects along with subsequent development of models were performed 3 times. Results Under the circumstances of isokinetic knee exercises with maximal effort and half the effort, 2 400 moment of force-time diagrams were produced, respectively. Classification accuracy rates of the CNN models after the 3 trainings were 91.11%, 90.49% and 92.08%, respectively, and the average accuracy rate was 91.23%. Conclusion The CNN models developed in this study have a good effect on differentiating isokinetic moment of force-time diagrams of maximal effort exercises from those made with half the effort, which can contribute to identifying levels of efforts exerted by subjects during isokinetic knee exercises.
Collapse
Affiliation(s)
- S W Chen
- Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, China
| | - D N Cui
- Institutes of Biomedical Sciences, Fudan University, Shanghai 200032, China
| | - Q Xia
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Key Laboratory of Forensic Science, Ministry of Justice, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - J Q Jiang
- Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, China
| | - Y W Shen
- Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai 200032, China
| |
Collapse
|
3
|
Liu RJ, Xia WT. Comparative Analysis of Visual System Disability Evaluation Criteria between China and the United States. Fa Yi Xue Za Zhi 2019; 35:607-612. [PMID: 31833298 DOI: 10.12116/j.issn.1004-5619.2019.05.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Indexed: 06/10/2023]
Abstract
Gradation of Disability in Human Body Injuries (hereinafter referred to as Gradation) has been released and used since January 2017, and has become the most widely used standard in forensic science practice. This paper calculates and rates the visual system evaluation provisions of the current domestic disability evaluation criteria represented by the Gradation which used the methods of Guides to the Evaluation of Permanent Impairment (hereinafter referred to as GEPI) issued by American Medical Association (AMA). Through comparing, a good correlation between the provisions in Gradation and whole person impairment rating index in GEPI was shown. On the basis of this, suggestions are put forward to amend some provisions of Gradation, in order to provide reference for the revision and further improvement of domestic standards and provisions.
Collapse
Affiliation(s)
- R J Liu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
4
|
Yu XY, Tan SL, Tang WY, Chen JM, Wang M, Liu RJ, Xia WT. Application of PRVEP Waveform Amplitude Ratio to Evaluate Visual Acuity and Its Forensic Significance. Fa Yi Xue Za Zhi 2019; 35:402-405. [PMID: 31532146 DOI: 10.12116/j.issn.1004-5619.2019.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Indexed: 11/30/2022]
Abstract
Abstract Objective To research the correlation between the visual acuity ratio and pattern reversal visual evoked potential (PRVEP) P100 waveform amplitude ratio of both eyes. Methods Forty-seven volunteers were selected, and the visual chart visual acuity of both eyes was measured. The visual acuity ratio of the eye with poor vision to the eye with better vision was calculated by five grade notation method. The amplitudes of P100 waveforms of both eyes were recorded respectively by using black-and-white checkerboard PRVEP and chosing 1°, 15' stimulating visual angle, and the ratio of amplitudes between the two eyes was also calculated. SPSS 20.0 software was used to analyze the correlation between the visual acuity ratio and the ratio of P100 waveform amplitudes between the two eyes. Return test and linear regression analysis with the binocular ratio of P100 waveform amplitudes as the independent variable (x) and the binocular visual acuity ratio as the dependent variable (y) were made. Results There was a positive correlation between the binocular visual acuity ratio and the ratio of P100 waveform amplitudes under 15' stimulating visual angle (Pearson correlation coefficient was 0.62, P=0.000). The fitting linear regression equation was y=0.090 x+0.846 (F=20.954, P=0.000). There was no significant correlation between the binocular ratio of visual acuity and the binocular ratio of P100 waveform amplitudes under 1° stimulating visual angle (P>0.05). Results of return test showed that there was no statistical significance in the difference between visual acuity estimated by equation and actual detected visual acuity. Conclusion In forensic appraisal of monocular injury, fitting linear regression equation of binocular visual acuity ratio and the binocular ratio of P100 waveform amplitudes under 15' stimulating visual angle, is helpful for visual acuity level estimation of the injured eye to some extent.
Collapse
Affiliation(s)
- X Y Yu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - S L Tan
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W Y Tang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China.,School of Basic Medical Science, Jiamusi University, Kiamusze 154000, Heilongjiang Province, China
| | - J M Chen
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - M Wang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - R J Liu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
5
|
Zhuo PP, Gao D, Ran D, Xia Q, Tan SL, Xia WT. Progress on the Muscle Function Evaluation and Its Forensic Application. Fa Yi Xue Za Zhi 2018; 34:665-671. [PMID: 30896109 DOI: 10.12116/j.issn.1004-5619.2018.06.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Indexed: 11/30/2022]
Abstract
Accurate evaluation of muscle function helps to understand the recovery of muscle, bone, nervous system diseases or injuries, especially for muscle dysfunction caused by peripheral nerve injury. Therefore, the methods of muscle function evaluation have been the focus of researchers, with new methods having been constantly proposed. Muscle strength testing is an important part of muscle function evaluation. Besides hand muscle strength assessment, currently used muscle function assessments include simple instrumental test, isokinetic muscle test, electrophysiological test, etc. In addition, the application of needle electromyography, motor unit number estimation, motion unit index in muscle function evaluation has also been reported for several times. This paper reviews the research progress and practical application of these methods.
Collapse
Affiliation(s)
- P P Zhuo
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China.,Department of Forensic Medicine, Wenzhou Medical University, Wenzhou 325035, Zhejiang Province, China
| | - D Gao
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - D Ran
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Q Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - S L Tan
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
6
|
Zhuo PP, Wang MW, Yu XY, Wan L, Tan SL, Chen JM, Xia WT. Assessment of the Original Height of L 1~2 after Vertebral Compression Fracture. Fa Yi Xue Za Zhi 2018; 34:359-362. [PMID: 30465398 DOI: 10.12116/j.issn.1004-5619.2018.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To explore the assessment method of original height of L1-2 after vertebral compression fracture and its application value in forensic clinical practice. METHODS A total of 154 normal thoracic and lumbar X-ray films were collected, and 140 cases were used as experimental group while 14 cases as validation group. The heights of anterior (Ha) and posterior (Hp) vertebral body of T₁₂-L₃ vertebrae in each X-ray image were measured. In the experimental group, the correlation analysis between HaL₁ and HaT₁₂, HpT₁₂, HpL₁, HaL₂ and HpL₂ was carried out, and regression equation was established via fitting. The correlation analysis between HaL₂ and HaL₁, HpL₁, HpL₂, HaL₃, HpL₃ was performed, and the regression equation was also established via fitting. The difference between the predicted and measured values of HaL₁ and HaL₂ in validation group was compared. RESULTS In the 140 normal subjects, HaL₁ (y₁) was well correlated with HaT₁₂ (x₁) and HaL₂(x₂), and the multiple linear regression equation was y₁=2.545+0.423 x₁+0.486 x₂ (determining coefficient R²=0.712, P<0.05; F=169.206, P<0.05). There was no significant difference between the predicted and actual measured values of HaL₁ in the validation group ( P>0.05). HaL₂ (y₂) was well correlated with HaL₁ (x₃) and HaL₃ (x₄), and the multiple linear regression equation was y₂=4.354+0.530 x₃+0.349 x₄ (determining coefficient R²=0.689, P<0.05; F=151.575, P<0.05). There was no significant difference between the predicted and actual measured values of HaL₂ in the validation group ( P>0.05). CONCLUSIONS It is more appropriate to evaluate the original height of L₁ or L₂ single vertebrae by comparing with the height of the anterior edge of the upper and lower adjacent vertebral bodies.
Collapse
Affiliation(s)
- P P Zhuo
- Department of Forensic Medicine, Wenzhou Medical University, Wenzhou 325035, China.,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - M W Wang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - X Y Yu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - L Wan
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - S L Tan
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China.,Department of Forensic Medicine, Medical College of Soochow University, Suzhou 215006, China
| | - J M Chen
- Department of Forensic Medicine, Medical College of Soochow University, Suzhou 215006, China
| | - W T Xia
- Department of Forensic Medicine, Medical College of Soochow University, Suzhou 215006, China
| |
Collapse
|
7
|
Tan SL, Chen JM, Wang M, Zhou S, Xia WT. [Research Progress of the Effects of Monocular Visual Impairment on Binocular Vision]. Fa Yi Xue Za Zhi 2018; 34:67-72. [PMID: 29577708 DOI: 10.3969/j.issn.1004-5619.2018.01.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Indexed: 11/18/2022]
Abstract
Binocular vision refers to a progress of analysing and integrating the binocular visual signals into a whole and three-dimensional sensory perception by higher nerve centre. In this process, the interac- tion between the two eyes results in the changes of output signal, which is called binocular interaction. Through a series of subjective and objective experiments, it can be concluded that binocular interaction can be divided into three types: facilitation, summation and suppression, and the forms of binocular interaction in different visual states are different. In general, the visual signal is processed by binocular interaction, so that there are some differences between binocular vision and monocular vision. The extent of the difference can be affected by the damage of monocular vision and then affects the binocular vision. Thus, it is necessary for forensic scientists to further study the effects of the monocular visual impairment on visual function. Based on relevant data, this paper reviews the mechanism of the monocular visual impairment in binocular vision, the research methods and the application prospect in forensic science.
Collapse
Affiliation(s)
- S L Tan
- Department of Forensic Medicine, Medical College of Soochow University, Suzhou 215123, China.,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - J M Chen
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - M Wang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - S Zhou
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
8
|
Xia Q, Zhang M, Gao D, Xia WT. [Range of Hip Joint Motion and Weight of Lower Limb Function under 3D Dynamic Marker]. Fa Yi Xue Za Zhi 2018; 33:595-598. [PMID: 29441765 DOI: 10.3969/j.issn.1004-5619.2017.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To explore the range of reasonable weight coefficient of hip joint in lower limb function. METHODS When the hip joints of healthy volunteers under normal conditions or fixed at three different positions including functional, flexed and extension positions, the movements of lower limbs were recorded by LUKOtronic motion capture and analysis system. The degree of lower limb function loss was calculated using Fugl-Meyer lower limb function assessment form when the hip joints were fixed at the aforementioned positions. One-way analysis of variance and Tamhane's T2 method were used to proceed statistics analysis and calculate the range of reasonable weight coefficient of hip joint. RESULTS There were significant differences between the degree of lower limb function loss when the hip joints fixed at flexed and extension positions and at functional position. While the differences between the degree of lower limb function loss when the hip joints fixed at flexed position and extension position had no statistical significance. In 95% confidence interval, the reasonable weight coefficient of hip joint in lower limb function was between 61.05% and 73.34%. CONCLUSIONS Expect confirming the reasonable weight coefficient, the effects of functional and non-functional positions on the degree of lower limb function loss should also be considered for the assessment of hip joint function loss.
Collapse
Affiliation(s)
- Q Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - M Zhang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China.,Criminal Justice College, East China University of Political Science and Law, Shanghai 200042, China
| | - D Gao
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
9
|
Wang M, Yu XY, Chen JM, Liu RJ, Xia WT. [Contrast Visual Evoked Potentials under Pattern Stimulus in Ocular Trauma]. Fa Yi Xue Za Zhi 2017; 33:21-24. [PMID: 29231003 DOI: 10.3969/j.issn.1004-5619.2017.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To study the characteristic of contrast visual evoked potentials (CVEP) in patients with ocular trauma. METHODS Sixty patients defined as ocular trauma by forensic clinical examination in our center were selected, and split into 0.2-0.3 (Group A), 0.3-0.5 (Group B) and ≥0.5 (Group C) according to the best corrected visual acuity. The variation characteristics of wave amplitude and latency of CVEP under 100%, 25% and 10% contrast were observed and analyzed statistically. RESULTS (1) Under the same contrast, the wave amplitude of P₁₀₀ decreased with the decrease of stimulus perspective. (2) Under the same stimulus perspective, the wave amplitude of P₁₀₀ decreased with the decrease of contrast (P<0.05). (3) Under the contrast of 100% and 25% with the same stimulus perspective (except 100% 7' perspective stimulus), the difference between group A and group B had no statistical significance (P>0.05). Between group A and group C, group B and group C, the wave amplitude of P₁₀₀ gradually increased with the increase of vision (P<0.05). Under the contrast of 10% with 15' stimulus perspective, the wave amplitude of P₁₀₀ increased with the increase of vision (P<0.05). (4) Under the same contrast with the same stimulation perspective, the latency of P₁₀₀ wave shortened with the increase of vision, while the difference had no statistical significance (P>0.05). Under the same stimulus perspective, the latency of P₁₀₀ wave was prolonged with the decrease of contrast (P>0.05). CONCLUSIONS CVEP may become one of the possible methods for the evaluation of contrast visual acuity.
Collapse
Affiliation(s)
- M Wang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - X Y Yu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - J M Chen
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - R J Liu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| |
Collapse
|
10
|
Tan SL, Chen JM, Yu XY, Wang MW, Zhuo PP, Zhou S, Xia WT. [Comparison of Measurement Methods of Exophthalmos and Its Forensic Significance]. Fa Yi Xue Za Zhi 2017; 33:353-356. [PMID: 29219263 DOI: 10.3969/j.issn.1004-5619.2017.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To compare the differences between Hertel exophthalmometry and CT on exophthalmos measurement, and explore its practical application value in forensic medicine. METHODS Fifty-six normal individuals without eye injuries or diseases were selected as the control group. The absolute values of exophthalmos were measured in the standardized CT image workstation. The difference of binocular exophthalmos was compared in normal group. Forty-seven cases with unilateral orbital fracture were divided into injured eye group and normal eye group according to the presence of binocular orbital fractures. The differences of the absolute values of eophthalmos from the same eye and the relative values of eophthalmos between two eyes for same person measured by Hertel exophthalmometry and CT were analyzed. RESULTS There was no statistical difference of exophthalmos between the normal eyes measured by CT method. In the normal eye group, the absolute value of exophthalmos measured by CT method was (16.66±5.41) mm, which was (16.16±4.45) mm when measured by the Hertel exophthalmometry method. There was no statistical difference between two groups (P>0.05). In the injured eye group, there was statistical difference between the absolute values of exophthalmos measured by two measurement methods ( P<0.05). There was no statistical difference of the relative values of exophthalmos between the injured eyes and the normal eyes by two measurement methods (P>0.05). CONCLUSIONS CT method has a good consistency with Hertel exophthalmometry, which can be applied into the practice of medicolegal expertise.
Collapse
Affiliation(s)
- S L Tan
- Department of Forensic Medicine, Medical College of Soochow University, Suzhou 215006, China.,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - J M Chen
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - X Y Yu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - M W Wang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - P P Zhuo
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China.,School of Basic Medical Sciences, Wenzhou Medical University, Wenzhou 325035, China
| | - S Zhou
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| | - W T Xia
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China
| |
Collapse
|
11
|
Jiang RS, Xia WT, Chen XY, Geng ZY, Hu ZY. Density of Contour Feathers and Heat Tolerance in Chickens. Journal of Applied Animal Research 2010. [DOI: 10.1080/09712119.2010.10539521] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|