Iandolo A, Amato M, Dagna A, Poggio C, Abdellatif D, Franco V, Pantaleo G. Intracanal heating of sodium hypochlorite: Scanning electron microscope evaluation of root canal walls.
J Conserv Dent 2018;
21:569-573. [PMID:
30294123 PMCID:
PMC6161513 DOI:
10.4103/jcd.jcd_245_18]
[Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Introduction:
The aim of this study is to evaluate the surface of root canals dentine using scanning electron microscope (SEM) after instrumentation with rotary Nickel-Titanium systems and two different protocols of activation of sodium hypochlorite (NaOCl) (extracanal heating at 50°C and intracanal heating at 180°C), to assess the presence/absence of smear layer and also the presence/absence of open dentinal tubules along the walls at the coronal, middle, and apical third of each sample.
Materials and Methods:
Thirty-six single-rooted teeth were selected, divided into three groups and shaped with ProTaper Universal instruments following irrigation protocols with 5.25% NaOCl. At the end of the preparation, three different protocols of activation were used: nonheated NaOCl in Group A, extra-canal heated NaOCl at 50°C for Group B and intracanal heated NaOCl at 180°C for Group C. Specimens were cut longitudinally and analyzed by SEM at standard magnification of ×1000. The presence/absence of the smear layer as well as the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal–Wallis and Mann–Whitney U statistical tests and significance was predetermined at P < 0.05.
Results:
Kruskal–Wallis analysis of variance (ANOVA) for debris score showed significant differences among the Ni-Ti systems (P < 0.05). Mann–Whitney test confirmed that Group A presented significantly higher score values than other Ni-Ti systems. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples.
Discussion and Conclusions:
Intra-canal heating of NaOCl at 180°C proved to be more effective in obtaining clean canal walls. On the other hand, extra-canal heating at 50°C of NaOCl left a higher quantity of debris and the smear layer was widely represented.
Collapse