Martin S, Cobetto N, Larson AN, Aubin CE. Biomechanical modeling and assessment of lumbar vertebral body tethering configurations.
Spine Deform 2023;
11:1041-1048. [PMID:
37179281 DOI:
10.1007/s43390-023-00697-8]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 04/29/2023] [Indexed: 05/15/2023]
Abstract
PURPOSE
Vertebral body tethering (VBT) is a fusionless spinal growth modulation technique, which shows promise for pediatric idiopathic scoliosis (IS) curve correction. This technique, mainly used for thoracic curves, is increasingly being used to treat lumbar curves in order to preserve spine flexibility. It remains necessary to adequately define the cord tension to be applied during the operation and the instrumented levels to biomechanically predict correction over time for the lumbar spine.
METHODS
Twelve pediatric patients with lumbar IS, treated with lumbar-only or lumbar and thoracic VBT, were selected for this study. Three independent variables were tested alternately using a patient-specific finite element model (FEM), which includes an algorithm modeling vertebra growth and spine curve changes due to growth modulation for 24 months post-operatively according to the Hueter-Volkmann principle. Parameters included cable tensioning (150N/250N), upper instrumented level (actual UIV, UIV-1) and lower instrumented level (actual LIV, LIV + 1). Each FEM was personalized using 3D radiographic reconstruction and flexibility supine radiographs.
RESULT
An increase in cord tension (from 150 to 250N) had significant effects on main thoracic and thoraco-lumbar/lumbar Cobb angles, as well as on lumbar lordosis, after surgery (supplementary average correction of 3° and 8°, and increase of 1.4°, respectively) and after 24 months (4°, 10° and 1.1°) (p < 0.05). Adding a level to the actual UIV or LIV did not improve correction.
CONCLUSION
This parametric study showed that cord tension is the most important biomechanical parameter on the simulated immediate and 2-year increase in lumbar curve correction. Our preliminary model suggests that it is not advantageous to add additional instrumented levels.
LEVEL OF EVIDENCE
This computational study uses a retrospective validation cohort (level of evidence 3).
Collapse