1
|
Ni C, Jiang D. Three-Dimensional Numerical Simulation of Particle Focusing and Separation in Viscoelastic Fluids. Micromachines (Basel) 2020; 11:E908. [PMID: 33007973 PMCID: PMC7599618 DOI: 10.3390/mi11100908] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 09/28/2020] [Accepted: 09/29/2020] [Indexed: 01/14/2023]
Abstract
Particle focusing and separation using viscoelastic microfluidic technology have attracted lots of attention in many applications. In this paper, a three-dimensional lattice Boltzmann method (LBM) coupled with the immersed boundary method (IBM) is employed to study the focusing and separation of particles in viscoelastic fluid. In this method, the viscoelastic fluid is simulated by the LBM with two sets of distribution functions and the fluid-particle interaction is calculated by the IBM. The performance of particle focusing under different microchannel aspect ratios (AR) is explored and the focusing equilibrium positions of the particles with various elasticity numbers and particle diameters are compared to illustrate the mechanism of particle focusing and separation in viscoelastic fluids. The results indicate that, for particle focusing in the square channel (AR = 1), the centerline single focusing becomes a bistable focusing at the centerline and corners as El increases. In the rectangular channels (AR < 1), particles with different diameters have different equilibrium positions. The equilibrium position of large particles is closer to the wall, and large particles have a faster lateral migration speed and few large particles migrate towards the channel center. Compared with the square channel, the rectangular channel is a better design for particle separation.
Collapse
Affiliation(s)
| | - Di Jiang
- School of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China;
| |
Collapse
|
2
|
Natu R, Guha S, Dibaji SAR, Herbertson L. Assessment of Flow through Microchannels for Inertia-Based Sorting: Steps toward Microfluidic Medical Devices. Micromachines (Basel) 2020; 11:E886. [PMID: 32987728 PMCID: PMC7598645 DOI: 10.3390/mi11100886] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 09/22/2020] [Accepted: 09/22/2020] [Indexed: 11/16/2022]
Abstract
The development of new standardized test methods would allow for the consistent evaluation of microfluidic medical devices and enable high-quality products to reach the market faster. A comprehensive flow characterization study was conducted to identify regulatory knowledge gaps using a generic inertia-based spiral channel model for particle sorting and facilitate standards development in the microfluidics community. Testing was performed using 2-20 µm rigid particles to represent blood elements and flow rates of 200-5000 µL/min to assess the effects of flow-related factors on overall system performance. Two channel designs were studied to determine the variability associated with using the same microchannel multiple times (coefficient of variation (CV) of 27% for Design 1 and 18% for Design 2, respectively). The impact of commonly occurring failure modes on device performance was also investigated by simulating progressive and complete channel outlet blockages. The pressure increased by 10-250% of the normal channel pressure depending on the extent of the blockage. Lastly, two common data analysis approaches were compared-imaging and particle counting. Both approaches were similar in terms of their sensitivity and consistency. Continued research is needed to develop standardized test methods for microfluidic systems, which will improve medical device performance testing and drive innovation in the biomedical field.
Collapse
Affiliation(s)
| | | | | | - Luke Herbertson
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA; (R.N.); (S.G.); (S.A.R.D.)
| |
Collapse
|
3
|
Kale A, Malekanfard A, Xuan X. Analytical Guidelines for Designing Curvature-Induced Dielectrophoretic Particle Manipulation Systems. Micromachines (Basel) 2020; 11:E707. [PMID: 32708326 PMCID: PMC7407939 DOI: 10.3390/mi11070707] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/15/2020] [Accepted: 07/20/2020] [Indexed: 12/31/2022]
Abstract
Curvature-induced dielectrophoresis (C-iDEP) is an established method of applying electrical energy gradients across curved microchannels to obtain a label-free manipulation of particles and cells. This method offers several advantages over the other DEP-based methods, such as increased chip area utilisation, simple fabrication, reduced susceptibility to Joule heating and reduced risk of electrolysis in the active region. Although C-iDEP systems have been extensively demonstrated to achieve focusing and separation of particles, a detailed mathematical analysis of the particle dynamics has not been reported yet. This work computationally confirms a fully analytical dimensionless study of the electric field-induced particle motion inside a circular arc microchannel, the simplest design of a C-iDEP system. Specifically, the analysis reveals that the design of a circular arc microchannel geometry for manipulating particles using an applied voltage is fully determined by three dimensionless parameters. Simple equations are established and numerically confirmed to predict the mutual relationships of the parameters for a comprehensive range of their practically relevant values, while ensuring design for safety. This work aims to serve as a starting point for microfluidics engineers and researchers to have a simple calculator-based guideline to develop C-iDEP particle manipulation systems specific to their applications.
Collapse
Affiliation(s)
- Akshay Kale
- Electrical Engineering Division, CAPE Building, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, UK
| | - Amirreza Malekanfard
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634, USA; (A.M.); (X.X.)
| | - Xiangchun Xuan
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634, USA; (A.M.); (X.X.)
| |
Collapse
|
4
|
Lu SY, Malekanfard A, Beladi-Behbahani S, Zu W, Kale A, Tzeng TR, Wang YN, Xuan X. Passive Dielectrophoretic Focusing of Particles and Cells in Ratchet Microchannels. Micromachines (Basel) 2020; 11:E451. [PMID: 32344887 DOI: 10.3390/mi11050451] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 04/09/2020] [Accepted: 04/23/2020] [Indexed: 12/19/2022]
Abstract
Focusing particles into a tight stream is critical for many microfluidic particle-handling devices such as flow cytometers and particle sorters. This work presents a fundamental study of the passive focusing of polystyrene particles in ratchet microchannels via direct current dielectrophoresis (DC DEP). We demonstrate using both experiments and simulation that particles achieve better focusing in a symmetric ratchet microchannel than in an asymmetric one, regardless of the particle movement direction in the latter. The particle focusing ratio, which is defined as the microchannel width over the particle stream width, is found to increase with an increase in particle size or electric field in the symmetric ratchet microchannel. Moreover, it exhibits an almost linear correlation with the number of ratchets, which can be explained by a theoretical formula that is obtained from a scaling analysis. In addition, we have demonstrated a DC dielectrophoretic focusing of yeast cells in the symmetric ratchet microchannel with minimal impact on the cell viability.
Collapse
|
5
|
Xuan X. Recent Advances in Continuous-Flow Particle Manipulations Using Magnetic Fluids. Micromachines (Basel) 2019; 10:E744. [PMID: 31683660 PMCID: PMC6915689 DOI: 10.3390/mi10110744] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 10/28/2019] [Accepted: 10/29/2019] [Indexed: 12/11/2022]
Abstract
Magnetic field-induced particle manipulation is simple and economic as compared to other techniques (e.g., electric, acoustic, and optical) for lab-on-a-chip applications. However, traditional magnetic controls require the particles to be manipulated being magnetizable, which renders it necessary to magnetically label particles that are almost exclusively diamagnetic in nature. In the past decade, magnetic fluids including paramagnetic solutions and ferrofluids have been increasingly used in microfluidic devices to implement label-free manipulations of various types of particles (both synthetic and biological). We review herein the recent advances in this field with focus upon the continuous-flow particle manipulations. Specifically, we review the reported studies on the negative magnetophoresis-induced deflection, focusing, enrichment, separation, and medium exchange of diamagnetic particles in the continuous flow of magnetic fluids through microchannels.
Collapse
Affiliation(s)
- Xiangchun Xuan
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA.
| |
Collapse
|
6
|
Cho M, Hong SO, Lee SH, Hyun K, Kim JM. Effects of Ionic Strength on Lateral Particle Migration in Shear-Thinning Xanthan Gum Solutions. Micromachines (Basel) 2019; 10:E535. [PMID: 31443169 PMCID: PMC6723194 DOI: 10.3390/mi10080535] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 08/08/2019] [Accepted: 08/12/2019] [Indexed: 01/22/2023]
Abstract
Viscoelastic fluids, including particulate systems, are found in various biological and industrial systems including blood flow, food, cosmetics, and electronic materials. Particles suspended in viscoelastic fluids such as polymer solutions migrate laterally, forming spatially segregated streams in pressure-driven flow. Viscoelastic particle migration was recently applied to microfluidic technologies including particle counting and sorting and the micromechanical measurement of living cells. Understanding the effects on equilibrium particle positions of rheological properties of suspending viscoelastic fluid is essential for designing microfluidic applications. It has been considered that the shear-thinning behavior of viscoelastic fluid is a critical factor in determining the equilibrium particle positions. This work presents the lateral particle migration in two different xanthan gum-based viscoelastic fluids with similar shear-thinning viscosities and the linear viscoelastic properties. The flexibility and contour length of the xanthan gum molecules were tuned by varying the ionic strength of the solvent. Particles suspended in flexible and short xanthan gum solution, dissolved at high ionic strength, migrated toward the corners in a square channel, whereas particles in the rigid and long xanthan gum solutions in deionized water migrated toward the centerline. This work suggests that the structural properties of polymer molecules play significant roles in determining the equilibrium positions in shear-thinning fluids, despite similar bulk rheological properties. The current results are expected to be used in a wide range of applications such as cell counting and sorting.
Collapse
Affiliation(s)
- Mira Cho
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea
| | - Sun Ok Hong
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea
| | - Seung Hak Lee
- School of Chemical and Biomolecular Engineering, Pusan National University, Busan 46241, Korea
| | - Kyu Hyun
- School of Chemical and Biomolecular Engineering, Pusan National University, Busan 46241, Korea.
| | - Ju Min Kim
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea.
- Department of Chemical Engineering, Ajou University, Suwon 16499, Korea.
| |
Collapse
|
7
|
Kale A, Patel S, Xuan X. Three-Dimensional Reservoir-Based Dielectrophoresis (rDEP) for Enhanced Particle Enrichment. Micromachines (Basel) 2018; 9:E123. [PMID: 30424057 PMCID: PMC6187384 DOI: 10.3390/mi9030123] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 02/24/2018] [Accepted: 03/09/2018] [Indexed: 01/01/2023]
Abstract
Selective enrichment of target species is crucial for a wide variety of engineering systems for improved performance of subsequent processes. Dielectrophoresis (DEP) is a powerful electrokinetic method that can be used to focus, trap, concentrate, and separate a variety of species in a label-free manner. The commonly employed methods for DEP suffer from limitations such as electrode fouling and high susceptibility to Joule heating effects. Recently, our group has demonstrated DEP-based manipulations of particles and cells using a novel method of reservoir-based dielectrophoresis (rDEP) which exploits the naturally produced electric field gradients at the reservoir-microchannel junction. Although this method reasonably addresses the limitations mentioned above while maintaining a high simplicity of fabrication, all of our demonstrations so far have used a two-dimensional rDEP, which limits the performance of the devices. This work aims to improve their performance further by making the DEP three-dimensional. Through detailed experimental and numerical analysis, we demonstrate a six-fold increase in the enrichment performance of latex beads and a significant reduction in the power consumption for the new devices, which would allow a more reliable integration of the same into micro-total analysis systems.
Collapse
Affiliation(s)
- Akshay Kale
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA.
- Department of Chemical Engineering & Biotechnology, University of Cambridge, Cambridge CB3 0AS, UK.
| | - Saurin Patel
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA.
| | - Xiangchun Xuan
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634-0921, USA.
| |
Collapse
|
8
|
Yuan D, Pan C, Zhang J, Yan S, Zhao Q, Alici G, Li W. Tunable Particle Focusing in a Straight Channel with Symmetric Semicircle Obstacle Arrays Using Electrophoresis-Modified Inertial Effects. Micromachines (Basel) 2016; 7:E195. [PMID: 30404368 DOI: 10.3390/mi7110195] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 10/13/2016] [Accepted: 10/19/2016] [Indexed: 12/27/2022]
Abstract
In this work, a novel microfluidic platform for tunable particle focusing in a straight channel with symmetric semicircle obstacle arrays using electrophoresis (EP)-modified inertial effects was presented. By exerting an EP force on the charged microparticles, a relative velocity gap between microspheres and fluid in a straight channel with symmetric semicircle obstacle arrays was implemented. The relative velocity and fluid shear will induce shear-slip lift force (Saffman lift force) perpendicular to the mainstream direction. Therefore, the focusing pattern can be altered using the electrophoresis-induced Saffman force. The effects of electric field direction, flow rate, electric field magnitude, and particle size were also studied. This demonstrates the possibility of adjusting the particle inertial focusing pattern in a straight channel with with symmetric semicircle obstacle arrays using electrophoresis. Manipulation of the lateral migration of focusing streaks increases controllability in applications such as blood cell filtration and the separation of cells by size.
Collapse
|
9
|
Qiu Y, Vlassiouk I, Hinkle P, Toimil-Molares ME, Levine AJ, Siwy ZS. Role of Particle Focusing in Resistive-Pulse Technique: Direction-Dependent Velocity in Micropores. ACS Nano 2016; 10:3509-3517. [PMID: 26901283 DOI: 10.1021/acsnano.5b07709] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Passage time through single micropores is an important parameter used to quantify the surface charge and zeta potential of particles. In the resistive-pulse technique, the measured time of pressure- or electric-field-induced translocation is assumed to be direction independent. This assumption is supported by the low velocities of the particles and the supporting fluid such that the transport reversibility known for Stokes flow is expected to apply. In this article, we present examples of micropores in which passage time of ∼400 nm diameter particles becomes direction-dependent; that is, the particles' translocation times from left to right and right to left are different. These pores are characterized by an undulating inner diameter such that at least one wider zone called a cavity separates two narrower regions of different lengths. We propose that the observed direction-dependence of the translocation velocity is caused by an asymmetric efficiency of particle focusing toward the pore axis, which leads to a direction-dependent set of particle trajectories. The reported pores present the simplest system in which time-broken symmetry has been observed. The results are of importance for sensing of particles and molecules by the resistive-pulse technique since pores used for detection are often characterized by finite roughness or noncylindrical shape. This article also points to the role of particle focusing in the magnitude and distribution of the translocation times.
Collapse
Affiliation(s)
- Yinghua Qiu
- Department of Physics and Astronomy, University of California , Irvine, California 92697, United States
- School of Mechanical Engineering and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing 211189, China
| | - Ivan Vlassiouk
- Oak Ridge National Laboratory , 1 Bethel Valley Road, Oak Ridge, Tennessee 37831, United States
| | - Preston Hinkle
- Department of Physics and Astronomy, University of California , Irvine, California 92697, United States
| | | | | | - Zuzanna S Siwy
- Department of Physics and Astronomy, University of California , Irvine, California 92697, United States
| |
Collapse
|
10
|
Vykoukal J, Schwartz JA, Gascoyne PRC, Yu C, Shi L. DIELECTROPHORESIS BASED MICRO FLOW CYTOMETRY. Micro Total Anal Syst 2003:1153-1156. [PMID: 23989303 PMCID: PMC3754898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We report a simplified flow cytometer design that makes use of negative dielectrophoresis (DEP) for particle focusing and integrated optical and AC impedance detectors to enable an inexpensive, compact and robust system for cell and particle characterization. This straightforward, modular design could be applied as a standalone instrument or as a particle detector in an integrated micro total analysis system.
Collapse
|